  • Why are my hard drives failing?

    - by WishCow
    I have a small Ubuntu server running at home, with 2 HDDs. There are two software raids (raid1) on the disks, managed by mdadm, which I believe is irrelevant, but mentioning it anyway. Both of the HDDs are Western Digital, and have been used for around 2 years, when one of them started making clicking noises, and died. I figured that maybe it's natural after 2 years, so I bought a new one, and resynced the raid arrays. After about a month, the other drive also died. I didn't get suspicious, since both drives have been bought at the same time, it's not that surprising to see both of them near each other, so I bought another one. So far, 2 old drives failed, and 2 brand new in the system. After one month, one of the new drives died. This is when it started getting suspicious. Since the PC was put together from some really old parts (think AthlonXP), I figured that maybe the motherboard's SATA controller is the culprit. Of course you can't switch parts easily in an old PC like this, so I bought a whole system, new MB, new CPU, new RAM. Took the just failed drive back, since it was under warranty, and got it replaced. So it is up to 2 failed drives from the old ones, and 1 failed drive from the new ones. No problems, for 1 month. After that errors were creeping up again in /var/log/messages, and mdadm was reporting raid array failures. I started tearing my hair out. Everything is new in the system, it's up to the third brand new HDD, it's simply not possible that all of the new drives that I bought were faulty. Let's see what is still common... the cables. Okay, long shot, let's replace the SATA cables. Take HDD back, smile to the guy at the counter and say that I'm really unlucky. He replaces the HDD. I come home, one month passes and one of HDDs fails, again. I'm not joking. Two of the brand new HDDs have failed. Maybe it's a bug in the OS. Let's see what the manufacturer's testing tool says. Download testing tool, burn it to a CD, reboot, leave HDD testing overnight. Test says that the drive is faulty, and I should back up everything, if I still can. I don't know what's happening, but it does not look like a software problem, something is definitely thrashing the HDDs. I should mention now, that the whole system is in a shoebox. Since there are a load of "build your own ikea case" stuff, I thought there shouldn't be any problems throwing the thing in a box, and stuffing it away somewhere. The box is well ventilated, but I thought that just maybe the drives were overheating. There is no other possible answer to this. So I took the HDD back, and got it replaced (for the 3rd time), and bought HDD coolers. And just now, I have heard the sound of doom. click click whizzzzzzzzz. SSH into the box: You have new mail! mail r 1 DegradedArrayEvent on /dev/md0 ... dmesg output: [47128.000051] ata3: lost interrupt (Status 0x50) [47128.000097] end_request: I/O error, dev sda, sector 58588863 [47128.000134] md: super_written gets error=-5, uptodate=0 [48043.976054] ata3: lost interrupt (Status 0x50) [48043.976086] ata3.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [48043.976132] ata3.00: cmd c8/00:18:bf:40:52/00:00:00:00:00/e1 tag 0 dma 12288 in [48043.976135] res 40/00:00:00:4f:c2/00:00:00:00:00/00 Emask 0x4 (timeout) [48043.976208] ata3.00: status: { DRDY } [48043.976241] ata3: soft resetting link [48044.148446] ata3.00: configured for UDMA/133 [48044.148457] ata3.00: device reported invalid CHS sector 0 [48044.148477] ata3: EH complete Recap: No possibility of overheating 6 drives have failed, 4 of those have been brand new. I'm not sure now that the original two have been faulty, or suffered the same thing that the new ones. There is nothing common in the system, apart from the OS which is Ubuntu Karmic now (started with Jaunty). New MB, new CPU, new RAM, new SATA cables. No, the little holes on the HDD are not covered I'm crying. Really. I don't have the face to return to the store now, it's not possible for 4 drives to fail under 4 months. A few ideas that I have been thinking: Is it possible that I fuck up something when I partition and resync the drives? Can it be so bad that it physicaly wrecks the drive? (since the vendor supplied tool says that the drive is damaged) I do the partitoning with fdisk, and use the same block size for the raid1 partitions (I check the exact block sizes with fdisk -lu) Is it possible that the linux kernel or mdadm, or something is not compatible with this exact brand of HDDs, and thrashes them? Is it possible that it may be the shoebox? Try placing it somewhere else? It's under a shelf now, so humidity is not a problem either. Is it possible that a normal PC case will solve my problem (I'm going to shoot myself then)? I will get a picture tomorrow. Am I just simply cursed? Any help or speculation is greatly appreciated. Edit: The power strip is guarded against overvoltage. Edit2: I have moved inbetween these 4 months, so the possibility of the cause being "dirty" electricity in both places, is very low. Edit3: I have checked the voltages in the BIOS (couldn't borrow a multimeter), and they are all seem correct, the biggest discrepancy is in the 12V, because it's supplying 11.3. Should I be worried about that? Edit4: I put my desktop PC's PSU into the server. The BIOS reported much more accurate voltage readings, and also it has successfully rebuilt the raid1 array, which took some 3-4 hours, so I feel a little positive now. Will get a new PSU tomorrow to test with that. Also, attaching the picture about the box: (disregard the 3rd drive)

    Read the article

  • webserver horrible slow, sometimes incredible fast

    - by dhanke
    i am running a small community ( 6000+ Members ) on a non-virtual 64-bit ubuntu 11.04 system. I am not a Linux-pro, not even advanced, i just tried to setup a webserver, which does nothing special actually. Delivering some dynamic PHP and RoR websites is its task. So it might be that my configuration files do look horrible bad. Also, i might use the wrong vocabulary, so in doubt, please ask. Having a current all-time record of 520 registered users (board-accounts, no system-users) online at same time, average server-load is about 2.0 - 5.0. Meantime (~250 users) average server load value is at about 0.4 - 0.8, sometimes, on some expensive searches a bit higher. everything fine. From time to time however, the load increases up to 120 (120.0, not 12.0 ;) ). In this time, its hard to even connect via SSH, but when i reach the server, and use top/htop/iotop to see whats happening, i cannot identify any process causing high CPU load. iotop tells me about a current reading/writing speed of about approx. 70kb/s, which is quite equal to power-off i think. Memory-Usage is max. at ~ 12GB of 16GB, so swap remains empty. now the odd (at least for me:) waiting some minutes ( since i always get a bit into a panic when this happens, it feels like 5 minutes, but i suppose its more like 20-30 minutes) and the server is back to normal. everything continues as normal. another odd fact: when i run hdparm -tT /dev/sda, i get answer like: /dev/sda: Timing cached reads: 7180 MB in 2.00 seconds = 3591.13 MB/sec Timing buffered disk reads: 348 MB in 3.02 seconds = 115.41 MB/sec when i run the same command while the server is "frozen", the answer is like /dev/sda: <- takes about 5 minutes until this line appears Timing cached reads: 7180 MB in 2.00 seconds = 3591.13 MB/sec <- 5 more minutes Timing buffered disk reads: 348 MB in 3.02 seconds = 115.41 MB/sec <- another 5 minutes so the values are the same, but the quoted time is completely wrong. using time command as prefix also tells me that ~ 15 minutes were used. I searched in dmesg, /var/log/[messages|syslog] - nothing found. /var/log/errors however tells me that: Jul 4 20:28:30 localhost kernel: [19080.671415] INFO: task php5-fpm:27728 blocked for more than 120 seconds. Jul 4 20:28:30 localhost kernel: [19080.671419] "echo 0 /proc/sys/kernel/hung_task_timeout_secs" disables this message. multiple times. now that message does tell me that php5-fpm task was blocked or did block ? - but not if that is the cause or just one of the results of that "freeze". Anyone? to cut the long story short, i dont know where even to start analyzing. So if you can give me any advice by looking at following specs and configs, or ask me to provide more information, i`d be glad. Specs: 6 Core AMD Phenom(tm) II X6 1055T Processor * 16 Gigabyte Ram 2x 1.5 TB Seagate ST1500DL003-9VT16L via SATA 3 via SoftwareRaid (i suppose) Services: (due to service --status-all, those with [ + ]) nginx Webserver 1.0.14 mySQL 5.1.63 Server Ruby on Rails 2.3.11 ( passenger-nginx-module ) php5-fpm 5.3.6-13ubuntu3.7 SSH ido2db Further services: default crontab + nightly backup. syslog-ng Website consists of 2 subdomains, forum. and www. where forum is a phpBB3.x PHP-Board, and www a Ruby on Rails 2.3.11 application (portal). Mini-Note: sometimes i notice that the forum is pretty slow, in contrast to the always-fast (except for this "freeze") portal. Both share the same Database, but the portal is using it read-only. The Webserver is nginx, using phusion passenger module to communicate with the ruby-application. Also, for the forum it communicates with php5-fpm via socket: relevant nginx configuration parts ( with comments/questions starting by ; ) ; in case of freeze due to too high Filesystem activity, maybe adding a limit? #worker_rlimit_nofile 50000; user www-data; ; 6 cores, so i read 6 fits. maybe already wrong? worker_processes 6; pid /var/run/nginx.pid; events { worker_connections 1024; } http { passenger_root /var/lib/gems/1.8/gems/passenger-3.0.11; passenger_ruby /usr/bin/ruby1.8; ; the forum once featured a chat, which was working w/o websockets. ; so it was a hell of pull requests (deactivated now, freeze still happening) keepalive_timeout 65; keepalive_requests 50; gzip on; server { listen 80; server_name www.domain.tld; root /var/www/domain/rails/public; passenger_enabled on; } server { listen 80; server_name forum.domain.tld; location / { root /var/www/domain/forum; index index.php; } ; satic stuff to be handled by nginx location ~* ^/style/.+.(jpg|jpeg|gif|css|png|js|ico|xml)$ { access_log off; expires 30d; root /var/www/domain/forum/; } ; now the php magic, note the "backend"-fcgi_pass location ~ .php$ { fastcgi_split_path_info ^(.+\.php)(.*)$; fastcgi_pass backend; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME /var/www/domain/forum$fastcgi_script_name; include fastcgi_params; fastcgi_param QUERY_STRING $query_string; fastcgi_param REQUEST_METHOD $request_method; fastcgi_param CONTENT_TYPE $content_type; fastcgi_param CONTENT_LENGTH $content_length; fastcgi_intercept_errors on; fastcgi_ignore_client_abort off; fastcgi_connect_timeout 60; fastcgi_send_timeout 180; fastcgi_read_timeout 180; fastcgi_buffer_size 128k; fastcgi_buffers 256 16k; fastcgi_busy_buffers_size 256k; fastcgi_temp_file_write_size 256k; fastcgi_max_temp_file_size 0; } location ~ /\.ht { deny all; } } ;the php5-fpm socket. i read that /dev/shm/ whould be the fastes place for this. bad idea in general? upstream backend { server unix:/dev/shm/phpfpm; } ... } php5-fpm settings (i changed this values due to php5-fpm error log messages higher and higher.. (freeze-problem was there before as well)* listen = /dev/shm/phpfpm user = www-data group = www-data pm = dynamic ; holy, 4000! well, shinking this value to earth-level gave me ; 100s of 502 bad gateway commands. this values were quite stable. ; since there are only max 520 users online i dont get it, why i would need ; as many children as configured here. due to keep-alive maybe? ; asking questions is easier for me since restarting server will make ; my community-members angry ;) pm.max_children = 4000 pm.start_servers = 100 pm.min_spare_servers = 50 pm.max_spare_servers = 150 pm.max_requests = 10 pm.status_path = /status ping.path = /ping ping.response = pong slowlog = log/$pool.log.slow ;should i use rlimit? ;rlimit_files = 1024 chdir = / mysql/my.cnf [client] port = 3306 socket = /var/run/mysqld/mysqld.sock [mysqld_safe] socket = /var/run/mysqld/mysqld.sock nice = 0 [mysqld] user = mysql socket = /var/run/mysqld/mysqld.sock port = 3306 basedir = /usr datadir = /var/lib/mysql tmpdir = /tmp skip-external-locking bind-address = 127.0.0.1 key_buffer = 16M max_allowed_packet = 16M thread_stack = 192K thread_cache_size = 8 myisam-recover = BACKUP ; high number, but less gives some phpBB errors. max_connections = 450 table_cache = 512 ; i read twice the cpu cores, bad? thread_concurrency = 12 join_buffer_size = 2084K concurrent_insert = 3 query_cache_limit = 64M query_cache_size = 512M query_cache_type = 1 log_error = /var/log/mysql/error.log log_slow_queries = /var/log/mysql/mysql-slow.log long_query_time = 2 expire_logs_days = 10 max_binlog_size = 100M low_priority_updates=1 [mysqldump] quick quote-names max_allowed_packet = 16M [isamchk] key_buffer = 16M !includedir /etc/mysql/conf.d/ I used smartctl already, hdds seem to be fine. /proc/mdstatus quotes: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md3 : active raid1 sda3[1] 1459264192 blocks [2/1] [_U] md1 : active raid1 sda1[0] 3911680 blocks [2/1] [U_] unused devices: ulimit -a core file size (blocks, -c) 0 data seg size (kbytes, -d) unlimited scheduling priority (-e) 0 file size (blocks, -f) unlimited pending signals (-i) 127727 max locked memory (kbytes, -l) 64 max memory size (kbytes, -m) unlimited open files (-n) 1024 pipe size (512 bytes, -p) 8 POSIX message queues (bytes, -q) 819200 real-time priority (-r) 0 stack size (kbytes, -s) 8192 cpu time (seconds, -t) unlimited max user processes (-u) 127727 virtual memory (kbytes, -v) unlimited file locks (-x) unlimited I quote some questions in my configuration files, these are not (intentional) directly problem-related, but would be nice for me to know wether they are indeed questionable or done right. One additional Fact: my MYSQL-database is at 12GB size. i dont know if that does matter, but mytop sometimes shows me 4-5 seconds long insert queries, some are 20-30 seconds long. Its just a feeling that i am unable to prove (because i dont know how), but when i disable the database, the freeze seems not to happen. Example: i created a dummy rails application to see the development log. the app made some sql-queries, reads and inserts. the log quite often was like: DbTest Load (0.3ms) SELECT * FROM `db_test` WHERE (`db_test`.`id` = 31722) LIMIT 1 SQL (0.1ms) BEGIN DbTest Update (0.3ms) UPDATE `db_test` SET `updated_at` = '2012-07-04 23:32:34' WHERE `id` = 31722 - now the log stands still for 5-60 seconds. SQL (49.1ms) COMMIT - SQL-Update time in the log does not include freeze time Rendering test/index Completed in 96ms (View: 16, DB: 59) | 200 OK [http://localhost:9000/test] Bad part is: this mini-freeze here only happens from time to time as well. note: meanwhile i cannot even upload files via scp. I currently feel like running form bad to worse and back by googling for my server-problem due to immense lack of knowledge regarding server configurations. It still makes me wonder, why those problems even appear, since 250 users a time is not such a high amount, right? So my questions: whats wrong and how to fix? ;) or: what information can i provide to make the situation more clear? can you point at some critical bad configuration-line which i should consider to catch up in the documentation? are there any tools i can run to see some possible bottlenecks? any further advice? (next to: "pay someone who knows what he does" - its a private project, server costs enough already. :)) Thanks for your time and help. Best Regards, Daniel P.S.: i renamed the configfiles to domain.tld since i dont want to have any % more load to the server until its fixed. might be a exaggeratedly thought.. P.P.S: if i asked a complete duplicate question, sorry. my search results seemed to be quite specific in their own way.

    Read the article

< Previous Page | 17 18 19 20 21