  • Experience with MooseFS?

    - by brown.2179
    Anyone have any experience using MooseFS? I want an easy distributed storage platform to store static data archive of about 10 TB and serve it to 20-40 nodes. Also I want to be able to add storage as the archive grows without having to rebuild the filesystem. I don't care if it's a bit slow. I just want it to be simple and stable. Basically from what I can see for OS X it's between MooseFS and Gluster. Any other suggestions?

    Read the article

  • How to use a derived ControlTemplate in WPF

    - by Frank Fella
    The following xaml code works: <Window x:Class="DerivedTemplateBug.Window1" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:local="clr-namespace:DerivedTemplateBug" Title="Window1" Height="300" Width="300"> <Button> <Button.Template> <ControlTemplate> <Border BorderBrush="Black" BorderThickness="2"> <TextBlock>Testing!</TextBlock> </Border> </ControlTemplate> </Button.Template> </Button> </Window> Now, if you define the following data template: using System.Windows.Controls; namespace DerivedTemplateBug { public class DerivedTemplate : ControlTemplate { } } And then swap the ControlTemplate for the derived class: <Window x:Class="DerivedTemplateBug.Window1" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:local="clr-namespace:DerivedTemplateBug" Title="Window1" Height="300" Width="300"> <Button> <Button.Template> <local:DerivedTemplate> <Border BorderBrush="Black" BorderThickness="2"> <TextBlock>Testing!</TextBlock> </Border> </local:DerivedTemplate> </Button.Template> </Button> </Window> You get the following error: Invalid ContentPropertyAttribute on type 'DerivedTemplateBug.DerivedTemplate', property 'Content' not found. Can anyone tell my why this is the case?

    Read the article

  • What would be the optimal disk config for SQL Server 2008 R2?

    - by Kev
    We have a new Dell R710 server that came with the following storage configuration: 8 x 146GB SAS 10k 6Gbps disks 1 x Perc H700 Integrated Controller (2 x 4 disks - 2 ports each supporting 4 disks) What would be the optimal configuration if we were just after performance? What would be the optimal configuration if we were after performance but wanted data resilience. As per 2 above but with a hot standby disk? We plan to run Windows 2008 R2 and SQL Server 2008 R2. Maximising storage capacity isn't a prime concern.

    Read the article

  • What happens when the USB key or SD card I've installed VMware ESXi on fails?

    - by ewwhite
    An SD (SDHC) card installed in an HP ProLiant DL380p Gen8 server running VMware ESXi just failed. I encountered some rather ominous looking messages on the vCenter console and in the HP ProLiant ILO event log... Lost connectivity to the device ... backing the boot filesystem. As a result, host configuration changes will not be saved to persistent storage. Embedded Flash/SD-CARD: Error writing media 0, physical block 848880: Stack Exception. VMware advocates the use of USB and SD (SDHC) boot devices for ESXi. It was one of the main reasons the smaller footprint ESXi was developed (versus the older ESX). I've spent much time highlighting the differences between ESXi's installable and embedded modes to coworkers and clients. However, these failures do seem to happen. In this case, this is my third instance. Luckily, this is a vSphere cluster with SAN storage. What steps should be taken to remediate this failure?

    Read the article

  • AWS Large Instance: /mnt does not show all the space that should be available

    - by Emile Baizel
    I just created a Large (m1.large) 64 bit instance which comes with 850 GB instance storage. Look at the Large Instance http://aws.amazon.com/ec2/instance-types/ A 'df -h' from the root folder gives me the output below. The /mnt is where I'm thinking the instance storage is but here it is only showing me 414G. I have set up two servers and both are showing the same numbers. root@ip-11-11-11-11:/# df -h Filesystem Size Used Avail Use% Mounted on /dev/sda1 7.9G 1.1G 6.5G 14% / none 3.7G 112K 3.7G 1% /dev none 3.7G 0 3.7G 0% /dev/shm none 3.7G 48K 3.7G 1% /var/run none 3.7G 0 3.7G 0% /var/lock /dev/sdb 414G 199M 393G 1% /mnt

    Read the article

  • How do I stop Python install on Mac OS X from putting things in my home directory?

    - by Rob
    Hi, I'm trying to install Python from source on my Mac. (OS X 10.6.2, Python-2.6.5.tar.bz2) I've done this before and it was easy, but for some reason, this time after ./configure, and make, the sudo make install puts things some things in my home directory instead of in /usr/local/... where I expect. The .py files are okay, but not the .so files... RobsMac Python-2.6.5 $ sudo make install [...] /usr/bin/install -c -m 644 ./Lib/anydbm.py /usr/local/lib/python2.6 /usr/bin/install -c -m 644 ./Lib/ast.py /usr/local/lib/python2.6 /usr/bin/install -c -m 644 ./Lib/asynchat.py /usr/local/lib/python2.6 [...] running build_scripts running install_lib creating /Users/rob/Library/Python creating /Users/rob/Library/Python/2.6 creating /Users/rob/Library/Python/2.6/site-packages copying build/lib.macosx-10.4-x86_64-2.6/_AE.so - /Users/rob/Library/ Python/2.6/site-packages copying build/lib.macosx-10.4-x86_64-2.6/_AH.so - /Users/rob/Library/ Python/2.6/site-packages copying build/lib.macosx-10.4-x86_64-2.6/_App.so - /Users/rob/Library/ Python/2.6/site-packages [...] Later, this causes imports that require those .so files to fail. For example... RobsMac Python-2.6.5 $ python Python 2.6.5 (r265:79063, Apr 28 2010, 13:40:18) [GCC 4.2.1 (Apple Inc. build 5646) (dot 1)] on darwin Type "help", "copyright", "credits" or "license" for more information. >>> import zlib Traceback (most recent call last):     File "", line 1, in ImportError: No module named zlib Any ideas what is wrong? thanks, Rob

    Read the article

  • Measuring accesses to files - apache

    - by George
    So, I run a website, that among other things serves some files (usually PDFs). All of these are stored under a specific directory on the server: /var/www/vhosts/mysite.com/httpdocs/site/pdf_files Due to storage issues on my VPS I am thinking of getting some S3 or other cloud storage, and mount it as a drive using S3QL/S3FS. Then I will be able to have the pdf_files folder symlinked to the cloud folder and serve those files using that, without any changes on the web app (is that a good plan?) Now, before doing that, to estimate costs, I need to measure how many file accesses people do, how many times those pdf files are downloaded each month for example. Basically how many times those pdf files are accessed through the webserver. I'd like to do it on the apache level. What's the best way that this can be done? e.g.: measuring the bandwidth used by files in that specific folder would also be nice, but estimating the GET requests I'll be doing to amazon is more important.

    Read the article

  • Using section header in Sendgrid

    - by Zefiryn
    I am trying to send emails through sendgrid in Zend application. I copy the php code from the sendgrid documentation (smtapi class and swift). I create a template with places that should be substituted with %variable%. Now I create headers for sendgrid as defined here: http://docs.sendgrid.com/documentation/api/smtp-api/developers-guide/ In result I get something looking like this: { "to": ["[email protected]", "[email protected]", "[email protected]", "[email protected]", "[email protected]"], "sub": {"%firstname%": ["Benny", "Chaim", "Ephraim", "Yehuda", "will"]}, "section": {"%postername%": "Rabbi Yitzchak Lieblich", "%postermail%": "[email protected]", "%categoryname%": "General", "%threadname%": "Completely new thread", "%post%": "This thread is to inform you about something very important", "%threadurl%": "http:\/\/hb.local\/forums\/general\/thread\/143", "%replyto%": "http:\/\/hb.local\/forums\/general\/thread\/143", "%unsubscribeurl%": "http:\/\/hb.local\/forums\/settings\/", "%subscribeurl%": "http:\/\/hb.local\/forums\/subscribe-thread\/id\/143\/token\/1b20eb7799829e22ba2d48ca0867d3ce"} } Now while all data defined in "sub" changes I cannot make section work. In the final email I still got %postername%. When I move this data to sub and repeat them for each email everything is working fine. Has anyone a clue what I am doing wrong? Docs for section are here: http://docs.sendgrid.com/documentation/api/smtp-api/developers-guide/section-tags/

    Read the article

  • Backup strategy for Windows Server 2008 R2 and Hyper-V

    - by winserveradmin
    I am in the process of planning a Hyper-V deployment with SCVMM 2008 R2. I have several VMs on VMWare Player (temporary solution) for stuff like Sharepoint 2007, 2010, and a couple of other server apps. I want to develop a resilient backup plan for this. On the software side, Data Protection Manager 2010 will support all of the server apps I run (sQL Server 2008 R2, Sharepoint, Exchange, etc). But on the hardware side (storage), what is the best way to go? Drobo seems to have issues with Hyper-V juding by a few threads on here and doesn't support DPM 2010 (which is in beta anyway) but not even the 2007 version (see http://www.drobo.com/support/best_practices.php). What storage device would work well? Do I need a home server or just an external usb drive? Capacity wise, 2tb will probably be best so I can have a small archive and implement a round-robin system. Thanks

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • NAS4Free disk encryption and ZFS error

    - by MiNT
    I have installed a NAS4Free on a VM, and as recommended, i installed it on a 1GB virtual disk, and assigned another disk 500GB to this VM for file storage. I have created the disk, encrypted it, created a ZFS virtual disk, and then a ZFS storage pool. Everything was working. On every restart of this VM i needed to go on and mount the encrypted drive. Recently i upgraded the host machine, and now i cant mount or make it work. I have tried removing everything and setting up from scratch everything, with the exception of formating the disk, i have used an encrypted one without formating it. Does anybody have any suggestion on how can i at least get back my data, can i mount somehow the encrypted drive even in another utility, just need to get back the data that were on it.

    Read the article

  • Django custom managers - how do I return only objects created by the logged-in user?

    - by Tom Tom
    I want to overwrite the custom objects model manager to only return objects a specific user created. Admin users should still return all objects using the objects model manager. Now I have found an approach that could work. They propose to create your own middleware looking like this: #### myproject/middleware/threadlocals.py try: from threading import local except ImportError: # Python 2.3 compatibility from django.utils._threading_local import local _thread_locals = local() def get_current_user(): return getattr(_thread_locals, 'user', None) class ThreadLocals(object): """Middleware that gets various objects from the request object and saves them in thread local storage.""" def process_request(self, request): _thread_locals.user = getattr(request, 'user', None) #### end And in the Custom manager you could call the get_current_user() method to return only objects a specific user created. class UserContactManager(models.Manager): def get_query_set(self): return super(UserContactManager, self).get_query_set().filter(creator=get_current_user()) Is this a good approach to this use-case? Will this work? Or is this like "using a sledgehammer to crack a nut" ? ;-) Just using: Contact.objects.filter(created_by= user) in each view doesn`t look very neat to me. EDIT Do not use this middleware approach !!! use the approach stated by Jack M. below After a while of testing this approach behaved pretty strange and with this approach you mix up a global-state with a current request. Use the approach presented below. It is really easy and no need to hack around with the middleware. create a custom manager in your model with a function that expects the current user or any other user as an input. #in your models.py class HourRecordManager(models.Manager): def for_user(self, user): return self.get_query_set().filter(created_by=user) class HourRecord(models.Model): #Managers objects = HourRecordManager() #in vour view you can call the manager like this and get returned only the objects from the currently logged-in user. hr_set = HourRecord.objects.for_user(request.user)

    Read the article

  • Replicate / SYNC / Copy thousands of files

    - by rihatum
    Windows 32BIT Box (Server OS) 4GB RAM a 800GB LUN Mapped to the above box as a local drive Around 700GB of text files (Yes text files and a few thousand word documents) nested in thousands of directories. I need to move this to a new storage and map another server to it. What would be the best way to go about it ? What I did was mapped the existing LUN to our new box and mapped a LUN from the New storage to the new box too, and tried copying (windows copy) but that wasn't good / fast enough considering the downtime. I am now looking for either a script which will do this or a utility (prefer opensource / free) to move this size of data at a good speed. 2 x 1GB Nics teamed ether channel 2GBPs Any suggestions or pointers would be off great help Thanks !

    Read the article

  • logparser Message with error codes

    - by nsr81
    Hi All, Is there anyway to get complete error message using LogParser? When I run the following query: logparser -i:EVT -o:NAT "SELECT TimeGenerated,EventID,Message from System WHERE EventTypeName='Error event'" I get the following output: 2009-09-02 19:35:44 7000 The USB Mass Storage Driver service failed to start due to the following error: %%1058 The full "Message" in EventViewer is: Description: The USB Mass Storage Driver service failed to start due to the following error: The service cannot be started, either because it is disabled or because it has no enabled devices associated with it. How can I obtain complete message using logparser?

    Read the article

  • Problem installing Cardbus/PCMCIA drivers (USB 2.0 2-port)

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • Problem sorting RSS feed by date using XSL

    - by Buckers
    I'm creating a website where I need to show the top 5 records from an RSS feed, and these need to be sorted by date and time. The date fields in the RSS feed are in the following format: "Mon, 16 Feb 2009 16:02:44 GMT" I'm having big problems getting the records to sort correctly - I've tried lots of different code examples I've seen, but none seem to sort the records correctly. The code for my XSL sheet is shown below, and the feed in question is here. Very grateful for anyones help!!! Thanks, Chris. XSL CODE: <xsl:stylesheet version="1.1" xmlns:xsl="http://www.w3.org/1999/XSL/Transform" xmlns:digg="http://digg.com//docs/diggrss/" xmlns:dc="http://purl.org/dc/elements/1.1/"> <xsl:template match="/"> <xsl:for-each select="//*[local-name()='item'][position() < 6]"> <p> <a> <xsl:attribute name="href"> <xsl:value-of select="*[local-name()='link']"/></xsl:attribute> <xsl:attribute name="target"> <xsl:text>top</xsl:text> </xsl:attribute> <xsl:value-of select="*[local-name()='title']"/> </a> <br/> <span class="smaller"><xsl:value-of select="*[local-name()='pubDate']" disable-output-escaping="yes"/></span> </p> </xsl:for-each>

    Read the article

  • Windows 8 Disk Mirroring vs Intel Fake RAID

    - by Johnny W
    So Windows 8 is out and I have a new motherboard. I wish to create a RAID 1 coupling between two HDDs -- for storage purposes only (my OS is on an SSD) -- but I don't know which is the best route to take. My motherboard (Z77 chipset) comes with the age old Intel Fake RAID, but since I only wish to use my RAID for storage, I wondered if I might be better to use Windows 8 Disk Mirroring. Can anyone advise which is better? Or perhaps the pros and cons of each, if that's too contentious? I just can't see the benefit of FakeRAID. You can see my current setup here, if that might change things(?): Thanks!

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS storage solutions. In addition, what effect does battery-backed write cache (BBWC) have in ZFS storage?

    Read the article

  • Status of Data in Rollback of Large Transaction in SQL Server

    - by Lloyd Banks
    I have a data warehousing procedure that downloads and replaces dozens of tables from a linked server to a local database. Every once in a while, the code will get stuck on one of the tables on the linked server because the table on the linked server is in a state of transition. I am under the assumption that since the entire procedure is considered one transaction commit, when the procedure gets stuck, none of the changes made by the procudure so far would have committed. But the opposite seems to be true, tables that were "downloaded" before the procedure got stuck would have been updated with today's versions on the local server. Shouldn't SQL Server wait for the entire procedure to finish before the changes are durable? CREATE PROCEDURE MYIMPORT AS BEGIN SET NOCOUNT ON IF EXISTS (SELECT * FROM INFORMATION.SCHEMA.TABLES WHERE TABLE_NAME = 'TABLE1') DROP TABLE TABLE1 SELECT COLUMN1, COLUMN2, COLUMN3 INTO TABLE1 FROM OPENQUERY(MYLINK, 'SELECT COLUMN1, COLUMN2, COLUMN3 FROM TABLE1') IF EXISTS (SELECT * FROM INFORMATION.SCHEMA.TABLES WHERE TABLE_NAME = 'TABLE2') DROP TABLE TABLE2 SELECT COLUMN1, COLUMN2, COLUMN3 INTO TABLE2 FROM OPENQUERY(MYLINK, 'SELECT COLUMN1, COLUMN2, COLUMN3 FROM TABLE2') --IF THE PROCEDURE GETS STUCK HERE, THEN CHANGES TO TABLE1 WOULD HAVE BEEN MADE ON THE LOCAL SERVER WHILE NO CHANGES WOULD HAVE BEEN MADE TO TABLE3 ON THE LOCAL SERVER IF EXISTS (SELECT * FROM INFORMATION.SCHEMA.TABLES WHERE TABLE_NAME = 'TABLE3') DROP TABLE TABLE3 SELECT COLUMN1, COLUMN2, COLUMN3 INTO TABLE3 FROM OPENQUERY(MYLINK, 'SELECT COLUMN1, COLUMN2, COLUMN3 FROM TABLE3') END

    Read the article

  • Python libusb pyusb "mach-o, but wrong architecture"

    - by Jon
    I am having some trouble with the pyusb module. I have narrowed down the problem to a single line, and have created a small example script to replicate the error. #!/usr/bin/env python """ This module was created to isolate the problem in the pyusb package. Operating system: Mac OS 10.6.3 Python Version: 2.6.4 libusb 1.0.8 has been successfully installed using: sudo port install libusb I have also tried modifying /opt/local/etc/macports/macports.conf to force the i386 architecture instead of x86_64. """ from ctypes import * import ctypes.util libname = ctypes.util.find_library('usb-1.0') print 'libname: ', libname l = CDLL(libname, RTLD_GLOBAL) # RESULT: #libname: /usr/local/lib/libusb-1.0.dylib #Traceback (most recent call last): # File "./pyusb_problem.py", line 7, in <module> # l = CDLL(libname, RTLD_GLOBAL) # File "/Library/Frameworks/Python.framework/Versions/2.6/lib/python2.6/ctypes/__init__.py", line 353, in __init__ # self._handle = _dlopen(self._name, mode) #OSError: dlopen(/usr/local/lib/libusb-1.0.dylib, 10): no suitable image found. Did find: # /usr/local/lib/libusb-1.0.dylib: mach-o, but wrong architecture # End of File This same script runs on Ubuntu 10.04 successfully. I have tried building the libusb module (directly from source AND through macports) for 32-bit (i386) instead of x86_64 (default for OS 10.6), but I receive the same error. Thank-you in advance for your help!

    Read the article

  • git pull not working

    - by dorelal
    I am not using github. We have git setup on our machine. I created a branch from master called experiment. However when I am trying to do git pull I am getting following message. > git pull You asked me to pull without telling me which branch you want to merge with, and 'branch.experiment.merge' in your configuration file does not tell me either. Please specify which branch you want to merge on the command line and try again (e.g. 'git pull <repository> <refspec>'). See git-pull(1) for details. Here is result of git remote show origin > git remote show origin * remote origin Fetch URL: ssh://git.domain.com/var/git/app.git Push URL: ssh://git.domain.com/var/git/app.git HEAD branch: master Remote branches: experiment tracked master tracked Local branches configured for 'git pull': master merges with remote master Local refs configured for 'git push': experiment pushes to experiment (local out of date) master pushes to master (up to date) As I read the message above experiment is mapped to origin/experiment. And my local repository knows that it is out of date. Then why I am not able to do git pull?

    Read the article

  • GlassFish Security Realm, Active Directory and Referral

    - by Allan Lykke Christensen
    I've setup up a Security Realm in Glassfish to authenticate against an Active Directory server. The configuration of the realm is as follows: Class Name: com.sun.enterprise.security.auth.realm.ldap.LDAPRealm JAAS context: ldapRealm Directory: ldap://172.16.76.10:389/ Base DN: dc=smallbusiness,dc=local search-filter: (&(objectClass=user)(sAMAccountName=%s)) group-search-filter: (&(objectClass=group)(member=%d)) search-bind-dn: cN=Administrator,CN=Users,dc=smallbusiness,dc=local search-bind-password: abcd1234! The realm is functional and I can log-in, but when ever I log in I get the following error in the log: SEC1106: Error during LDAP search with filter [(&(objectClass=group)(member=CN=Administrator,CN=Users,dc=smallbusiness,dc=local))]. SEC1000: Caught exception. javax.naming.PartialResultException: Unprocessed Continuation Reference(s); remaining name 'dc=smallbusiness,dc=local' at com.sun.jndi.ldap.LdapCtx.processReturnCode(LdapCtx.java:2820) .... .... ldaplm.searcherror While searching for a solution I found that it was recommended to add java.naming.referral=follow to the properties of the realm. However, after I add this it takes 20 minutes for GlassFish to authenticate against Active Directory. I suspect it is a DNS problem on the Active Directory server. The Active Directory server is a vanilla Windows Server 2003 setup in a Virtual Machine. Any help/recommendation is highly appreciated!

    Read the article

  • Issue with VMWare vSphere and NFS: re occurring apd state

    - by Bastian N.
    I am experiencing issues with VMWare vSphere 5.1 and NFS storage on 2 different setups, which result in an "All Path Down" state for the NFS shares. This first happened once or twice a day, but lately it occurs much more frequent, as specially when Acronis Backup jobs are running. Setup 1 (Production): 2 ESXi 5.1 hosts (Essentials Plus) + OpenFiler with NFS as storage Setup 2 (Lab): 1 ESXi 5.1 host + Ubuntu 12.04 LTS with NFS as storage Here is an example from the vmkernel.log: 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 248: APD Timer started for ident [987c2dd0-02658e1e] 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 395: Device or filesystem with identifier [987c2dd0-02658e1e] has entered the All Paths Down state. 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 846: APD Start for ident [987c2dd0-02658e1e]! 2013-05-28T08:07:37.485Z cpu0:2052)NFSLock: 610: Stop accessing fd 0x410007e4cf28 3 2013-05-28T08:07:37.485Z cpu0:2052)NFSLock: 610: Stop accessing fd 0x410007e4d0e8 3 2013-05-28T08:07:41.280Z cpu1:2049)StorageApdHandler: 277: APD Timer killed for ident [987c2dd0-02658e1e] 2013-05-28T08:07:41.280Z cpu1:2049)StorageApdHandler: 402: Device or filesystem with identifier [987c2dd0-02658e1e] has exited the All Paths Down state. 2013-05-28T08:07:41.281Z cpu1:2049)StorageApdHandler: 902: APD Exit for ident [987c2dd0-02658e1e]! 2013-05-28T08:07:52.300Z cpu1:3679)NFSLock: 570: Start accessing fd 0x410007e4d0e8 again 2013-05-28T08:07:52.300Z cpu1:3679)NFSLock: 570: Start accessing fd 0x410007e4cf28 again As long as the issue occurred once or twice a day it really wasn't a problem, but now this issue has impact on the VMs. The VMs get slow or even hang, resulting in a reset through vCenter in the production environment. I searched the web extensively and asked in forums, but till now nobody was able to help me. Based on blog posts and VMWare KB articles I tried the following NFS settings: Net.TcpipHeapSize = 32 Net.TcpipHeapMax = 128 NFS.HartbeatFrequency = 12 NFS.HartbeatMaxFailures = 10 NFS.HartbeatTimeout = 5 NFS.MaxQueueDepth = 64 Instead of NFS.MaxQueueDepth = 64 I already tried other settings like NFS.MaxQueueDepth = 32 or even NFS.MaxQueueDepth = 1. Unfortunately without any luck. It would be great if someone could help me on this issue. It is really annoying. Thanks in advance for all the help. [UPDATE] As I explained in the comment below, here is the network setup: On the production setup the NFS traffic is bound to a separate VLAN with ID 20. I am using a HP 1810 24 Port Switch. The OpenFiler system is connected to the VLAN with 4 Intel GbE NICs with dynamic LACP. The ESXis both have 4 Intel GbE NICs using 2 static LACP trunks containing 2 NICs each. One pair is connected to the regular LAN and the other one to the VLAN 20. And here is a screenshot of the vSwitch: Switch configuration: Port configuration: On the lab setup its a single Intel NIC on each side without VLAN, but with different IP subnet.

    Read the article

  • INNODB mysql. Plugin disabled

    - by alexcunn
    When I startup mysql on my unbuntu server I will get a message. 121122 17:39:37 [Note] Plugin 'FEDERATED' is disabled. 121122 17:39:37 InnoDB: The InnoDB memory heap is disabled 121122 17:39:37 InnoDB: Mutexes and rw_locks use GCC atomic builtins 121122 17:39:37 InnoDB: Compressed tables use zlib 1.2.3.4 121122 17:39:37 InnoDB: Initializing buffer pool, size = 128.0M InnoDB: mmap(137363456 bytes) failed; errno 12 121122 17:39:37 InnoDB: Completed initialization of buffer pool 121122 17:39:37 InnoDB: Fatal error: cannot allocate memory for the buffer pool 121122 17:39:37 [ERROR] Plugin 'InnoDB' init function returned error. 121122 17:39:37 [ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed. 121122 17:39:37 [ERROR] Unknown/unsupported storage engine: InnoDB 121122 17:39:37 [ERROR] Aborting 121122 17:39:37 [Note] mysqld: Shutdown complete a few times I have got a message saying that the plugin is disabled. I use webmin to configure it. Could that be a problem?

    Read the article

  • How to Remove a VM From Hyper-V Without Deleting the Configuration File?

    - by Steven Murawski
    I'm in the process of moving a number of virtual machines that are homed on shared storage (a file share, though shared cluster disk would work as well) to a new VM host with access to the same shared storage. The new host is a different build version (moving from Windows Server 2012 Beta to Windows Server 2012 RC - though this same process could be used with migrations of Windows Server 2008/2008 R2 to Windows Server 2012 as well), so I cannot migrate the machine with inbox tooling. I need to remove the VM from management of the source Hyper-V host in order to import the VM to the new Hyper-V host. I want to retain the configuration file, so I can import the VM as it stands and not need to reconfigure it. The VHD files are rather large and they are staying on the same file share, so I'd rather not duplicate them during the move process.