Search Results

Search found 13355 results on 535 pages for 'applescript studio'.

Page 213/535 | < Previous Page | 209 210 211 212 213 214 215 216 217 218 219 220  | Next Page >

  • Get an error when trying to set the build version with the AssemblyInfo Task

    - by Glenn Slaven
    I've added the AssemblyInfo Task reference to my C# project file (VS2008 .NET 3.5), but when I build I get the following error The "AssemblyInfo" task failed unexpectedly. System.ArgumentException: version Parameter name: The specified string is not a valid version number at Microsoft.Build.Extras.Version.ParseVersion(String version) at Microsoft.Build.Extras.AssemblyInfo.Execute() at Microsoft.Build.BuildEngine.TaskEngine.ExecuteInstantiatedTask(EngineProxy engineProxy, ItemBucket bucket, TaskExecutionMode howToExecuteTask, ITask task, Boolean& taskResult) My assemblyinfo file has these two attributes: [assembly: AssemblyVersion("1.0.0.0")] [assembly: AssemblyFileVersion("1.0.0.0")]

    Read the article

  • VS 2010 Profiling Problem with Signed Assemblies

    - by Binder
    I have a website that uses AjaxControlToolkit.dll and Log4Net.dll; When I try to run the performance profiling tool in VS 2010 on it it gives me the following warnings "AjaxControlToolkit.dll is signed and instrumenting it will invalidate its signature. If you proceed without a post-instrument event to re-sign the binary it may not load correctly". Now, if I choose the option to continue without re-signing the profiling starts but the assembly doesn't load and gives an ASP.NET exception.

    Read the article

  • How do I specify the manifest for side-by-side assemblies in my header file?

    - by sep
    I am developing in Visual C++ 2008 using MSMQ. In Windows Vista, the application cannot locate the mqrt.dll which is found at C:\Windows\winsxscd x86_microsoft-windows-msmq-runtime-core_31bf3856ad364e35_6. 0.6002.18005_none_574cf1cdb624ee17\mqrt.dll. The description of the manifest in WinSxS is: <assembly xmlns="urn:schemas-microsoft-com:asm.v3" manifestVersion="1.0" description="MSMQ core runtime component." displayName="MSMQ Core runtime component" company="Microsoft" copyright="Copyright (c) Microsoft Corporation. All Rights Reserved." creationTimeStamp="2005-03-11T01:47:18" lastUpdateTimeStamp="2005-03-11T01:48:59"> <assemblyIdentity name="Microsoft-Windows-msmq-runtime-core" version="6.0.6002.18005" processorArchitecture="x86" language="neutral" buildType="release" publicKeyToken="31bf3856ad364e35" versionScope="nonSxS" /> I added a #pragma comment into my header file: #pragma comment(linker, "\"/manifestdependency:name='Microsoft-Windows-msmq-runtime-core' version='6.0.6002.18005' processorArchitecture='x86' publicKeyToken='31bf3856ad364e35' language='neutral'\"") The manifest is embedded into the exe using mt.exe. But it does not work. The error message in sxstrace is: INFO: Resolving reference Microsoft-Windows-msmq-runtime-core,processorArchitecture="x86",publicKeyToken="31bf3856ad364e35",version="6.0.6002.18005". INFO: Resolving reference for ProcessorArchitecture x86. INFO: Resolving reference for culture Neutral. INFO: Applying Binding Policy. INFO: No publisher policy found. INFO: No binding policy redirect found. INFO: Begin assembly probing. INFO: Did not find the assembly in WinSxS. INFO: Attempt to probe manifest at C:\Windows\assembly\GAC_32\Microsoft-Windows-msmq-runtime-core\6.0.6002.18005__31bf3856ad364e35\Microsoft-Windows-msmq-runtime-core.DLL. INFO: Attempt to probe manifest at c:\qt\datamon\bin\Microsoft-Windows-msmq-runtime-core.DLL. INFO: Attempt to probe manifest at c:\qt\datamon\bin\Microsoft-Windows-msmq-runtime-core.MANIFEST. INFO: Attempt to probe manifest at c:\qt\datamon\bin\Microsoft-Windows-msmq-runtime-core\Microsoft-Windows-msmq-runtime-core.DLL. INFO: Attempt to probe manifest at c:\qt\datamon\bin\Microsoft-Windows-msmq-runtime-core\Microsoft-Windows-msmq-runtime-core.MANIFEST. INFO: Did not find manifest for culture Neutral. INFO: End assembly probing. ERROR: Cannot resolve reference Microsoft-Windows-msmq-runtime-core,processorArchitecture="x86",publicKeyToken="31bf3856ad364e35",version="6.0.6002.18005". ERROR: Activation Context generation failed. I tried the following pragma, but WinSxS does not even try to resolve msmq (probably because of the versionScope attribute): #pragma comment(linker, "\"/manifestdependency:name='Microsoft-Windows-msmq-runtime-core' version='6.0.6002.18005' processorArchitecture='x86' publicKeyToken='31bf3856ad364e35' language='neutral' buildType='release' versionScope='nonSxS'\"") What is the correct pragma to use?

    Read the article

  • Blend 4 breaks VS2010 for Silverlight

    - by Adrian
    Hi, I had VS2010 running fine with Silverlight development. Then I installed Expression Blend 4. Now when I run VS2010 and try to debug a silverlight app I get an error saying "Unable to start debugging. The silverlight developer runtime is not installed. Please install a matching version." I've tried uninstalling silverlight tools, and reinstalling them from scratch (the latest april version). But I still get the same message. So basically I'm now unable to do VS2010 SL development. I'm on the verge of just rolling back to my last system restore point and giving up on Blend. But if I do that I'd be worried that Product Activation would never allow me to reinstall it in the future, since the MSDN download page implies I'm only ever allowed to install it on a single machine. Any help appreciated. Thanks

    Read the article

  • How to return DropDownList selections dynamically in ASP.NET?

    - by salvationishere
    This is probably a simple question but I am developing a web app in C# with DropDownList. Currently it is working for just one DropDownList. But now that I modified the code so that number of DropDownLists that should appear is dynamic, it gives me error; "The name 'ddl' does not exist in the current context." The reason for this error is that there a multiple instances of 'ddl' = number of counters. So how do I instead return more than one 'ddl'? Like what return type should this method have instead? And how do I return these values? Reason I need it dynamic is I need to create one DropDownList for each column in whatever Adventureworks table they select. private DropDownList CreateDropDownLists() { for (int counter = 0; counter < NumberOfControls; counter++) { DropDownList ddl = new DropDownList(); SqlDataReader dr2 = ADONET_methods.DisplayTableColumns(targettable); ddl.ID = "DropDownListID" + (counter + 1).ToString(); int NumControls = targettable.Length; DataTable dt = new DataTable(); dt.Load(dr2); ddl.DataValueField = "COLUMN_NAME"; ddl.DataTextField = "COLUMN_NAME"; ddl.DataSource = dt; ddl.ID = "DropDownListID 1"; ddl.SelectedIndexChanged += new EventHandler(ddlList_SelectedIndexChanged); ddl.DataBind(); ddl.AutoPostBack = true; ddl.EnableViewState = true; //Preserves View State info on Postbacks //ddlList.Style["position"] = "absolute"; //ddl.Style["top"] = 80 + "px"; //ddl.Style["left"] = 0 + "px"; dr2.Close(); } return ddl; }

    Read the article

  • Web Site in solution where "Rebuild Solution" compile succeeds cannot launch debugger

    - by fordareh
    I have a solution that includes a Web Site (created using the web site template not the web app project template - converting isn't an option, btw). When I rebuild all, the compile succeeds, but strangely displays 3 errors, all of which are "Could not get dependencies for project reference 'PROJNAME'". When I try to launch the debugger, I get the "There were build errors." dialogue. Two questions: If I choose the 'Yes' option in the debug error dialogue to run the last successful build, will it run on the code that my Rebuild All just compiled? How do I resolve this issue? I checked this post and am disheartened by my prospects. What is strange, though, is that I added these same projects to a separate web site solution that compiled/debugged fine, removed the test web site and re-added the target website I would like to debug, and it failed in the same manner. Is there a secret web site .proj file for .NET web sites? http://stackoverflow.com/questions/863379/could-not-get-dependencies-for-project-reference

    Read the article

  • How to open a help webpage after installation is complete

    - by Kapil
    I have built an installer for my windows app using the VisualStudio 2008 IDE. I also use some custom-actions to do a few extra stuff at the time of installation/uninstallation. What I also want to do is that when the installation is completed, the installer should launch a help webpage or a getting-started page for the users to know how to go ahead with the app. I am doing the following for this: private void CustomInstaller_Committed(object sender, InstallEventArgs e) { System.Windows.Forms.LinkLabel lbl = new System.Windows.Forms.LinkLabel(); lbl.Links.Remove(lbl.Links[0]); lbl.Links.Add(0, lbl.Text.Length, "http://www.mywebsite.com/help.aspx"); ProcessStartInfo pInfo = new ProcessStartInfo(lbl.Links[0].LinkData.ToString()); Process.Start(pInfo); } Also, I set the event handler as such: this.Committed += new InstallEventHandler(CustomInstaller_Committed); This is launching the webpage, but not at the right point in the flow where I would have wanted it. It launches the IE browser even before the user dismisses the installation window (i.e clicks 'Close' in the Installation Completed dialog box). I want the webpage to open only when the user finally dismisses the installation. Any ideas how can I achieve this? Thanks, Kapil

    Read the article

  • Installing Loadrunner

    - by grouchomarx
    Well, it figures that Loadrunner is not easy to install. Apprently, we need: ? .NET Framework 3.5 ? Microsoft Data Access Components (MDAC) 2.8 SP1 (or later) ? Microsoft Windows Installer 3.1 ? Microsoft Core XML Services (MSXML) 6.0 ? Microsoft Visual C++ 2005 Redistributable Package (x86) ? Microsoft Visual C++ 2008 Redistributable Package (x86) ? Web Services Enhancements (WSE) 2.0 SP3 for Microsoft .NET Redistributable Runtime MSI ? Web Services Enhancements (WSE) 3.0 for Microsoft .NET Redistributable Runtime MSI Once done, I'm still trying to figure out how to execute this thing. Has anyone gone through the same experience with it ?

    Read the article

  • How to create a folder under %allusersprofile% during Setup with VS 2003 Setup Project?

    - by Romias
    I need to create a folder under "%allusersprofile%/Program Data" during the install process. The Setup file is created with VS 2003 setup project, and in it you can use several Known Folders... but as I see none maps to %allusersprofile% or "%allusersprofile%/Program Data". I thought that creating a "Custom Folder" (within VS Setup Project) and setting the TargetLocation as %allusersprofile% it would work, but during install it says that I don't have permission to that folder (and I do have). Do you know how to target that folder in VS Setup Project? Also... I'm working in Windows XP, so %allusersprofile% maps to "C:\Documents and Settings\All Users", but there I suppose I should create my folder inside the "Program Data" folder. In Vista, %allusersprofile% maps to "C:\ProgramData" and it look correct if I create my folder directly there. Any idea how to target both OSs? Additional info: I'm trying this to avoid the new security features in Vista, where the app can't write files under the Program Files folder when running as a common user at least. So I need to place the writable files on "common" folder that is not in a "per user" basis.

    Read the article

  • prevent the designer from calling a getter (VS 2008, WinForms)

    - by LLEA
    hi, I have a simple UserControl containing a ComboBox which is empty at first. The setter for that CB adds items to it and the getter returns the selected item. When adding this UC to a Form, the designer automatically calls the getter for the CB which is empty. The method to fill up the CB with items is called later. I can think of one or two ways to bypass this problem by "messing around" in the code. But before I start that I'd like to ask you if there is a way to stop the designer from calling the getter method. Maybe with a attribute similar to Browsable or Bindable? thx

    Read the article

  • COM Interop error, class not registered when using MSMQ Library

    - by mattmck
    I've referenced the MSMQ v3 Object Library in a VS2010 C# project only to get: System.Runtime.InteropServices.COMException (0x80040154): Retrieving the COM class factory for component with CLSID {0188401C-247A-4FED-99C6-BF14119D7055} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)). I've registered the library the reference points to: regsvr32 C:\windows\system32\mqoa.dll What am I missing? Assuming this works, what will I have to do at deployment to ensure the app will run on other machines with MSMQ installed?

    Read the article

  • Static method , Abstract method , Interface method comparision ?

    - by programmerist
    When i choose these methods? i can not decide which one i must prefer or when will i use one of them?which one give best performance? First Type Usage public abstract class _AccessorForSQL { public virtual bool Save(string sp, ListDictionary ld, CommandType cmdType); public virtual bool Update(); public virtual bool Delete(); public virtual DataSet Select(); } class GenAccessor : _AccessorForSQL { DataSet ds; DataTable dt; public override bool Save(string sp, ListDictionary ld, CommandType cmdType) { } public override bool Update() { return true; } public override bool Delete() { return true; } public override DataSet Select() { DataSet dst = new DataSet(); return dst; } Second Type Usage Also i can write it below codes: public class GenAccessor { public Static bool Save() { } public Static bool Update() { } public Static bool Delete() { } } Third Type Usage Also i can write it below codes: public interface IAccessorForSQL { bool Delete(); bool Save(string sp, ListDictionary ld, CommandType cmdType); DataSet Select(); bool Update(); } public class _AccessorForSQL : IAccessorForSQL { private DataSet ds; private DataTable dt; public virtual bool Save(string sp, ListDictionary ld, CommandType cmdType) { } } } I can use first one below usage: GenAccessor gen = New GenAccessor(); gen.Save(); I can use second one below usage: GenAccessor.Save(); Which one do you prefer? When will i use them? which time i need override method ? which time i need static method?

    Read the article

  • TortoiseSVN: how to set up projects on a existing directory structure of source code

    - by Steve
    I have an old pet project I want to revive (haven't had enough time for it last year - small kid - you know) - so restored old copy of my dev folder from archive, but since I have rebuilt my machine since when - I can't remember what needs to be done now. I installed the latest version of TortoiseSVN, and the existing directory structure from my old dev machine looks like: ProjectName *SubProject1 **branches ***1.1 ***1.2 **tags **trunk *SubProject2 **branches **1.0.3 **1.0.4 **1.0.5 **tags **trunk I tried "import project" but it ask for a url - don't know what to specify there ... can someone post a url to a good TortSVN tutorial - so I could set up my projects quickly (I guess I need to setup SubProject1 and SubProject2) - then I install AnkhSVN for VS2008 and will spend this Sunday coding like crazy while I still have some time ;-)

    Read the article

  • VS 2010 very slow

    - by kaze
    I have just upgraded to VS 2010, and I have performance problems which I did not have before (in VS 2008). The most annoying thing is that it freezes while I work in the text editor. Sometimes when it freezes I see that it is saving auto recovery information, but not always. Almost anything I do gives an unacceptable long delay, like saving, starting to debug, ending debug session, switching between design and code view, and doing WinForms designing. I have some parts of my home directory on a mapped network drive. I suspect that that might be a part of the problem. Is it possible to configure VS 2010 to use exclusively local disk for its "internal" work perhaps? Any hints would be appreciated! Has anyone else experienced these kinds of problems?

    Read the article

  • SOAP call with query on result (SSRS, Sharepoint)

    - by Erik404
    Hi! I created a report in VS using a shared data source which is connected to a sharepoint list. In the report I created a dataset with a SOAP call to the data source so I get the result from the sharepoint list in a table. this is the soap call <Query> <SoapAction>http://schemas.microsoft.com/sharepoint/soap/GetListItems</SoapAction> <Method Namespace="http://schemas.microsoft.com/sharepoint/soap/" Name="GetListItems"> <Parameters> <Parameter Name="listName"> <DefaultValue>{BD8D39B7-FA0B-491D-AC6F-EC9B0978E0CE}</DefaultValue> </Parameter> <Parameter Name="viewName"> <DefaultValue>{E2168426-804F-4836-9BE4-DC5F8D08A54F}</DefaultValue> </Parameter> <Parameter Name="rowLimit"> <DefaultValue>9999</DefaultValue> </Parameter> </Parameters> </Method> <ElementPath IgnoreNamespaces="True">*</ElementPath> </Query> THis works fine, I have a result which I can show in a report, but I want to have the ability to select a parameter to filter the result on. I have created a parameter and when I preview the Report I see the dropdownbox which I can use to make a selection from the Title field, when I do this it still shows the first record, obviously it doens't work yet (DUH!) because I need to create a query somewhere, But! I have no idea where, I tried to include <Where> <Eq> <FieldRef Name="ows_Title" /> <Value Type="Text">testValue</Value> </Eq> </Where> in the the soap request but it didn't worked... I've searched teh intarwebz but couldn't find any simliar problems... kinda stuck now...any thoughts on this? EDIT Here's the query I used according to the blogpost Alex Angas linked. <Query> <SoapAction>http://schemas.microsoft.com/sharepoint/soap/GetListItems</SoapAction> <Method Namespace="http://schemas.microsoft.com/sharepoint/soap/" Name="GetListItems"> <queryOptions></queryOptions> <query><Query> <Where> <Eq> <FieldRef Name="ows_Title"/> <Value Type="Text">someValue</Value> </Eq> </Where> </Query></query> <Parameters> <Parameter Name="listName"> <DefaultValue>{BD8D39B7-FA0B-491D-AC6F-EC9B0978E0CE}</DefaultValue> </Parameter> <Parameter Name="viewName"> <DefaultValue>{E2168426-804F-4836-9BE4-DC5F8D08A54F}</DefaultValue> </Parameter> <Parameter Name="rowLimit"> <DefaultValue>9999</DefaultValue> </Parameter> </Parameters> </Method> <ElementPath IgnoreNamespaces="True">*</ElementPath> </Query> I tried to put the new query statement in every possible way in the existing, but it doesn't work at all, I do not get an error though so the code is valid, but I still get an unfiltered list as return... pulling my hair out here!

    Read the article

  • Assembly reference in Silverlight class library and used only in xaml is not packaged in XAP

    - by Brandon Copeland
    I have a 3rd party library (A). That library is referenced in my Silverlight class library (B). That Silverlight class library is referenced in my Silverlight application (C). The 3rd party library is not explicitly referenced in the Silverlight application. It seems that "A" is added to my XAP if "A" is used in any class in "B" because of a chain in dependencies (C - B - A). This is the behavior I would expect and need. If "A" is never explicitly used in a C# class but only defined in Xaml, the assembly is not packaged to the XAP. Maybe "A" includes a control that is only used declaratively and never referenced otherwise. Is this behavior by design? Am I missing a property somewhere that controls this? I would prefer to not explicitly reference the third party library in my Silverlight application. What's to best practice to ensure all necessary assemblies are packaged in the XAP?

    Read the article

  • VS2010 Using SQL Server 2000

    - by Chris M
    Is there a way to use the SQL Model (dbml) builder in VS2010 using SQLServer2000? It works fine in VSExpress2008 + VS2008 but throws an "Upgrade SQL to 2005" error in VS2010 which seems a tad unreasonable.

    Read the article

  • Managing data charts

    - by Tom Gullen
    My dbml file is just getting bigger and bigger and more unwieldy: I favoured an all-in-one approach as supposed to multiple data contexts because when I tried that it was near impossible to manage in code. I was advised it was better to have them all in one chart and the difficulty will be simply in managing this chart and not in code. The chart I've got is becoming a pain to manage, if I want to even remove a table and re-add it it sometimes takes a little while to manually find it! There isn't even a list I can find in VS2010 of the objects you have in that chart! Is there a better way of doing this?

    Read the article

  • Visual Studion 2008 App_Data defaults

    - by Dennis Keith
    Is it possible to use the App_Data folder in conjunction with SQL Server 2005? When I try it specifies Express even though I have changed the ToolsOptionsDatabaseData Connections to the correct server. I have downloaded SQLEXPR32_x86_ENU.exe Version 10.0.1600.22 file locally and have gone through 7 installs and deinstalls with a variety of different errors. I pretty much given up on Express and would like to find a workaround if it exists. Thanks Dennis Keith

    Read the article

  • Refernce platform specific System.Data.SQLite

    - by Dmitriy Nagirnyak
    Hi, I am using SQLite for the unit testing and might use it as a database for local development/staging. The System.Data.SQLite has basically 2 versions: x86 and x64. Correct one should be used for the specific platform. I have 64 bit Win7, other guys in the team might use 32-bit OSs. The server's platform is not known at this stage. If I use 32-bit version of the assembly on 64-bit platform I get BadImageFormatException: Could not load file or assembly 'System.Data.SQLite'. I believe similar will happen trying to use 64-bit assembly on 32-bit platform. So my question is what is the best way to reference the SQLite assembly so that it does not depend on the platform and people can just use it? It is ok to use 32-bit version of assembly on a 64-bit platform (Maybe there is a switch for that somewhere?). Thanks, Dmitriy.

    Read the article

  • HttpWebRequest: The request was aborted: The request was canceled.

    - by Emeka
    I've been working on developing a middle man application of sorts, which uploads text to a CMS backend using HTTP post requests for a series of dates (usually 7 at a time). I am using HttpWebRequest to accomplish this. It seems to work fine for the first date, but when it starts the second date I get the System.Net.WebException: The request was aborted: The request was canceled. I've searched around and found the following big clues: http://social.msdn.microsoft.com/Forums/en-US/netfxnetcom/thread/0d0afe40-c62a-4089-9d8b-fb4d206434dc http://www.jaxidian.org/update/2007/05/05/8 http://arnosoftwaredev.blogspot.com/2006/09/net-20-httpwebrequestkeepalive-and.html And they haven't been too helpful. I've tried overloading the GetWebReuqest but that doesn't make sense because I don't make any use of that function. Here is my code: http://pastebin.org/115268 I get the error on line 245 after it has run successfully at least once. I'd appreciate any help I can get as this is the last step in a project I've been working on for sometime. This is my first C#/VS project so I'm open to any tips but I would like to focus on getting this problem solved first. THanks!

    Read the article

  • VS2010 / Code Analysis: Turn off a rule for a project without custom ruleset....

    - by TomTom
    ...any change? The scenario is this: For our company we develop a standard how code should look. This will be the MS full rule set as it looks now. For some specific projects we may want to turn off specific rules. Simply because for a specific project this is a "known exception". Example? CA1026 - while perfectly ok in most cases, there are 1-2 specific libraries we dont want to change those. We also want to avoid having a custom rule set. OTOH putting in a suppress attribute on every occurance gets pretty convoluted pretty fast. Any way to turn off a code analysis warning for a complete assembly without a custom rule set? We rather have that in a specific file (GlobalSuppressions.cs) than in a rule set for maintenance reasons, and to be more explicit ;)

    Read the article

< Previous Page | 209 210 211 212 213 214 215 216 217 218 219 220  | Next Page >