  • What software is responsible for connecting to the wireless net specified in /etc/network/interfaces?

    - by zuba
    I'm curious what software (package, utility in bin's) handle interface parameters in /etc/network/interfaces and decides to connect to the specified wireless net. I use wifi usb stick dlink DWL-110 attached to wlan0 with ndiswrapper driver. Sometimes wlan0 sees my wifi net - iwlist wlan0 scan shows it, but does not connect to it - iwconfig shows AP Not-Associated, until I replug the stick. Neither reinserting module with ndiswrapper, not ifdown/ifup or restarting networking helps. That is why I need to know what OS entity handles connection/reconnection to wireless net. EDIT: shame on me, I use wireless-tool package with wep encryption

    Read the article

  • How many megabytes per second may I expect from a gigabit USB 2.0 network card under linux?

    - by Nakedible
    I'm interested in the actual real-word throughput attainable with an external 1000BaseT USB 2.0 network card under Linux. I have been able to attain 90 megabytes per second on a PCI-E interface, but the USB 2.0 bus has a theoretical limit of 480Mbit/s, and in practice less than 40 megabytes per second. Is the actual throughput attainable with such a card under linux 40, 30, 20, or even as low as 10 megabytes per second, eg. no better than a normal 100BaseT network card?

    Read the article

  • Why Can't Computers Off My Network See the Site? [migrated]

    - by nmagerko
    Have just set up Apache, PHP, MySQL, etc. on my Ubuntu OS, and I was wondering why computers that are not on my network can not see the basic index.html that Apache uses as the default. I set up the static ip address for my computer, and I use 192.168.1.100 for computers to view the simple site. Is there something I am missing that will allow others to access my site? (It is REALLY simple; no graphics, CSS, etc.)

    Read the article

  • Why is a network ID not needed to connect to an IP address?

    - by baddogai
    I know how IP basically works, and knows that an IP address composed of a network ID portion and a host ID portion, but when I type a IP address, say 8.8.8.8 into the web browser, I didn't supply any subnet mask information. So, how does the browser know where the dividing line is between the network ID and host ID? Since 8.8.8.8 may mean 8.8.8.8/8, 8.8.8.8/24 etc. In a nutshell, the IP address I supplied is ambiguous.

    Read the article

  • SQLAuthority News Were sorry but your computer or network may be sending automated queries. To pro

    I use multiple browser many times when I am working with multiple projects simultaneously. Often I use Google Reader to read few feeds. Recently, I faced the following error and this error will not go. I even restarted my computer and rebooted my network. I am confident that my computer does not have viruses or [...]...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Google Chrome Browser does not display the images from Local network or local host? [migrated]

    - by Arjang
    While developing and testing a site on local network I have noticed that while IE/FireFox would display the images coming from URL's like "http:\mypc" or "http:\localhost" or ip adress on the netwrok , google chrome on Galaxy, Windows Machine, or google Android will not display the images. After having burned too many hours trying various CSS, image src tag, html document description tricks, I have given up. During my search I found (and lost) the link to chrome forums regarding this issue that seemed to say it is just so by users. Anyone has any more information on weather it is possible to view images on local host/computer name on netwrok or ip adress?

    Read the article

  • How do I access an external drive mounted on a machine on my own network?

    - by avilella
    I've got one desktop computer Ubuntu 11.04 with an external USB drive mounted on it on the home WRT54L Linux network (192.168.0.2), and when I arrive at home with my laptop, I want to be able to mount the external USB drive from my Ubuntu 11.04 laptop (192.168.0.3) to the desktop, without having to unplug it from the desktop, that is accessing it. Is it possible to send a remote mount command to the desktop usb drive from my laptop? Ideally something that creates a local mountpoint I can just call locally from the programs installed in my laptop, like: username@laptop ~ ./myprograminlaptop /my/file/which/is/actually/on/the/desktop/file.txt

    Read the article

  • Iomega Home Media Network Hard Drive 1TB Cloud Edition failed, data recovery?

    - by lonbon69
    I have a Iomega Home Media Network Drive Cloud Edition 1TB that started clicking and then displayed a failure LED code Power LED and Red LED. I removed the SATA drive and inserted in a 'All in 1 HDD Docking Station' and connected to laptop by USB - Laptop has Win 7 OS. The dock is seen as drive E but cannot access and says 0% data etc. The drive does spin up when I power the dock. Web searches say the drive has EXT3 file system and to use Ubuntu to access drive. I have now setup a dual boot laptop but still do not see the drive using ubuntu. Is there something else I need to do to get it recognised etc. I really would like to recover the data, any suggestions please?

    Read the article

  • 12.04: I need a new network card - and I think this one may work?

    - by Jason Malone
    I found this list of compatible USB wireless network adaptors: http://www.cyberciti.biz/tips/linux-usb-wireless-compatibility-adapter-list.html Listed here is the Belkin F5D8053. I'm looking for a store to buy a suitable adaptor in locally and I can't find that particular adaptor - but I can see a Belkin F7D4101az. I think this is simply a newer model - but a Google search for "ubuntu belkin f7d4101az" brings no results - not even people trying to get it to work. Nothing. So I didn't want to purchase it without being sure. There's really only one PC shop that sells this sort of stuff around here - so here's a list of all my available options: http://www.pcworld.co.uk/gbuk/wireless-cards-adapters/xx_7088_70095_xx_xx/xx-criteria.html I'd really like to get one today, because I have a lot of work to do and don't really want to have to wait a week for a new adaptor - I spent 6 or 7 hours last night trying to get my Dell 1450 to work with no luck. Any help would be much appreciated.

    Read the article

  • How is network traffic routed (VPN vs. 'open')?

    - by craibuc
    If my workstation has a VPN connection to a given network (a client's, for instance) and an open connection, what determines how a request for a network resource (e.g. a web page) is routed? Moreover, given that a resource (e.g. google.com) could be available via either route (i.e. VPN or non-VPN), how is this route determined? Is there a way to 'force' the routing to use a given route or the route with lower overhead?

    Read the article

  • No external network on ubuntu 9.10, though dns works..

    - by user29368
    Hi, I have a weird problem I cant solve. I have several computers, two with xubuntu 9.10 One of them, acting as a media server, has stopped to work when it comes to external network.. I can do for example: ping google.com Which gives me an ip adress back, like: name@Media:/etc$ ping google.com PING google.com (66.102.9.147) 56(84) bytes of data. That tells me it reaches the dns?, but I get no response at all... If I ping a local computer all works fine. I can also reach the computer via ssh without any problems. I have always used network manager, but now I uninstalled it and made the settings manually like this: /etc/network/interfaces auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 192.168.1.52 netmask 255.255.255.0 network 192.168.1.0 broadcast 192.168.1.255 gateway 192.168.1.1 Still no luck. I have no specific settings for this one in my router, and all the other computers, including my win laptop works fine. This is very annoying since I cant even do an update or anything.. ifconfig looks like this: eth0 Link encap:Ethernet HWaddr 00:24:1d:9f:10:89 inet addr:192.168.1.52 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::224:1dff:fe9f:1089/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:15410 errors:0 dropped:0 overruns:0 frame:0 TX packets:2693 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:1167398 (1.1 MB) TX bytes:694973 (694.9 KB) Interrupt:27 Base address:0xe000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:2150 errors:0 dropped:0 overruns:0 frame:0 TX packets:2150 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:143456 (143.4 KB) TX bytes:143456 (143.4 KB) route -n like this Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 192.168.1.0 0.0.0.0 255.255.255.0 U 0 0 0 eth0 169.254.0.0 0.0.0.0 255.255.0.0 U 1000 0 0 eth0 0.0.0.0 192.168.1.1 0.0.0.0 UG 100 0 0 eth0 I do not know where the adress starting with 169.254 comes from.. Could that be a part of the problem? Hoping for some assistance since Im totally stuck here.. /george

    Read the article

  • How can I make the Windows VPN route selective traffic (by destination network)?

    - by Legooolas
    I want to use a windows VPN but only for a particular network, so that it doesn't take over my entire network connection. e.g., Instead of the VPN becoming the default route, make it only the route for 192.168.123.0/24 (I can see that there is a solution for this for Ubuntu in this question, but sometimes I have to do this on Windows too) Can this be automated so that whenever I connect to the VPN it does this?

    Read the article

  • Is a VPN a good method for protecting data in an untrusted network? [closed]

    - by john
    I will be connecting my laptop in an untrusted network. If I setup OpenVpn on a server and use a vpn client on the laptop to connect through it, is it enough? Can someone perform a MITM attack or otherwise eavesdrop on my traffic? If someone on the local network port-scans my laptop, will the open ports be accessible to him while I use the VPN tunnel? Is there anything else I should keep in mind?

    Read the article

  • How to speed up the reading of innerHTML in IE8?

    - by Dennis Cheung
    I am using JQuery with the DataTable plugin, and now I have a big performnce issue on the following line. aLocalData[jInner] = nTds[j].innerHTML; // jquery.dataTables.js:2220 I have a ajax call, and result string in HTML format. I convert them into HTML nodes, and that part is ok. var $result = $('<div/>').html(result).find("*:first"); // simlar to $result=$(result) but much more faster in Fx Then I activate enable the result from a plain table to a sortable datatable. The speed is acceptable in Fx (around 4sec for 900 rows), but unacceptable in IE8 (more then 100 seconds). I check it deep using the buildin profiler, and found the above single line take all 99.9% of the time, how can I speed it up? anything I missed? nTrs = oSettings.nTable.getElementsByTagName('tbody')[0].childNodes; for ( i=0, iLen=nTrs.length ; i<iLen ; i++ ) { if ( nTrs[i].nodeName == "TR" ) { iThisIndex = oSettings.aoData.length; oSettings.aoData.push( { "nTr": nTrs[i], "_iId": oSettings.iNextId++, "_aData": [], "_anHidden": [], "_sRowStripe": '' } ); oSettings.aiDisplayMaster.push( iThisIndex ); aLocalData = oSettings.aoData[iThisIndex]._aData; nTds = nTrs[i].childNodes; jInner = 0; for ( j=0, jLen=nTds.length ; j<jLen ; j++ ) { if ( nTds[j].nodeName == "TD" ) { aLocalData[jInner] = nTds[j].innerHTML; // jquery.dataTables.js:2220 jInner++; } } } }

    Read the article

  • How can I speed up Subversion checkins? (Using ANKH, latest, Visual Studio 2010)

    - by Timothy Khouri
    I've started working on a new web project with some friends... we are using the latest Subversion server (installed last week), the latest version of ANKH. My web project is a whapping 1.5 megabytes (that's with all images, css files, dll's after compiling, pdb files... etc). Checking in even super small changes (literally adding the letter "x" to a few files for testing)... takes FOREVER! (about 10 seconds - I almost killed myself). The ANKH client is measuring in BYTES PER SECOND ... BYTES? per second... I must be doing something wrong. Does anyone what config file has a joke totallyMessWithPeople=true so that I can turn that off or something? Oh, also, changing one "big" file of a super 10k gains speed up to nearly the speed of light (which is apparently 857 bytes per second). Help me obi wan kenobi, your my only hope! EDIT: As a note... my real work project that uses Visual Source Safe 2005 (I know, ouch) uploads files at about 200-500kbps from this very same computer/internet connection.

    Read the article

  • Why does Tex/Latex not speed up in subsequent runs?

    - by Debilski
    I really wonder, why even recent systems of Tex/Latex do not use any caching to speed up later runs. Every time that I fix a single comma*, calling Latex costs me about the same amount of time, because it needs to load and convert every single picture file. (* I know that even changing a tiny comma could affect the whole structure but of course, a well-written cache format could see the impact of that. Also, there might be situations where 100% correctness is not needed as long as it’s fast.) Is there something in the language of Tex which makes this complicated or impossible to accomplish or is it just that in the original implementation of Tex, there was no need for this (because it would have been slow anyway on those large computers)? But then on the other hand, why doesn’t this annoy other people so much that they’ve started a fork which has some sort of caching (or transparent conversion of Tex files to a format which is faster to parse)? Is there anything I can do to speed up subsequent runs of Latex? Except from putting all the stuff into chapterXX.tex files and then commenting them out?

    Read the article

  • How do I optimize this postfix expression tree for speed?

    - by Peter Stewart
    Thanks to the help I received in this post: I have a nice, concise recursive function to traverse a tree in postfix order: deque <char*> d; void Node::postfix() { if (left != __nullptr) { left->postfix(); } if (right != __nullptr) { right->postfix(); } d.push_front(cargo); return; }; This is an expression tree. The branch nodes are operators randomly selected from an array, and the leaf nodes are values or the variable 'x', also randomly selected from an array. char *values[10]={"1.0","2.0","3.0","4.0","5.0","6.0","7.0","8.0","9.0","x"}; char *ops[4]={"+","-","*","/"}; As this will be called billions of times during a run of the genetic algorithm of which it is a part, I'd like to optimize it for speed. I have a number of questions on this topic which I will ask in separate postings. The first is: how can I get access to each 'cargo' as it is found. That is: instead of pushing 'cargo' onto a deque, and then processing the deque to get the value, I'd like to start processing it right away. I don't yet know about parallel processing in c++, but this would ideally be done concurrently on two different processors. In python, I'd make the function a generator and access succeeding 'cargo's using .next(). But I'm using c++ to speed up the python implementation. I'm thinking that this kind of tree has been around for a long time, and somebody has probably optimized it already. Any Ideas? Thanks

    Read the article

  • How can I speed up a 1800-line PHP include? It's slowing my pageload down to 10sec/view

    - by somerandomguy
    I designed my code to put all important functions in a single PHP file that's now 1800 lines long. I call it in other PHP files--AJAX processors, for example--with a simple "require_once("codeBank.php")". I'm discovering that it takes about 10 seconds to load up all those functions, even though I have nothing more than a few global arrays and a bunch of other functions involved. The main AJAX processor code, for example, is taking 8 seconds just to do a simple syntax verification (whose operational function is stored in codeBank.php). When I comment out the require_once, my AJAX response time speeds up from 10sec to 40ms, so it's pretty clear that PHP's trying to do something with those 1800 lines of functions. That's even with APC installed, which is surprising. What should I do to get my code speed back to the sub-100ms level? Am I failing to get the cache's benefit somehow? Do I need to cut that single function bank file into different pieces? Are there other subtle things that I could be doing to screw up my response time? Or barring all that, what are some tools to dig further into which PHP operations are hitting speed bumps?

    Read the article

  • Why can't gif images copy at a reasonable speed on this dell laptop with XP?

    - by alt234
    I've got this somewhat old Dell Latitude D810. Strangest thing... If I try to copy anything that has gif files in it the gif files take forever. Like a few minutes per gif regardless of size. Everything else copies fine. I notice this when copying files off our network, copying off multiple external drives, and even when files are copying during an installation process. I'm on Windows XP Pro service pack 3. I've never seen anything like this before. Anyone else?

    Read the article

  • Fan not working on thinkpad L430, laptop overheating

    - by Dirk B.
    I'm having problems controlling the fan of my Lenovo Thinkpad L430. The fan doesn't start. Without any fan control installed the fan just doesn't run. If I run stress, it does run a little, but it's nowhere near the speed it should be. After a while, the laptop just overheats and stops. I Tried to install tp-fancontrol, and enabled thinkpad_acpi fancontrol=1, but to no avail. If I try to set the fan speed manually, it doesn't start up. In windows, there's a program called TPFanControl. It turns out that this laptop uses a different scheme to control the fan than other thinkpads. The level runs from 0 to 255, and max = 0 and min=255. Now I'm looking for a fan control program that works for linux. Does anyone know if it actually exists? Anyone with any experience on fan control on a L430? Update: sudo pwmconfig gives the following output: # pwmconfig revision 5857 (2010-08-22) This program will search your sensors for pulse width modulation (pwm) controls, and test each one to see if it controls a fan on your motherboard. Note that many motherboards do not have pwm circuitry installed, even if your sensor chip supports pwm. We will attempt to briefly stop each fan using the pwm controls. The program will attempt to restore each fan to full speed after testing. However, it is ** very important ** that you physically verify that the fans have been to full speed after the program has completed. Found the following devices: hwmon0 is acpitz hwmon1/device is coretemp hwmon2/device is thinkpad Found the following PWM controls: hwmon2/device/pwm1 hwmon2/device/pwm1 is currently setup for automatic speed control. In general, automatic mode is preferred over manual mode, as it is more efficient and it reacts faster. Are you sure that you want to setup this output for manual control? (n) y Giving the fans some time to reach full speed... Found the following fan sensors: hwmon2/device/fan1_input current speed: 0 ... skipping! There are no working fan sensors, all readings are 0. Make sure you have a 3-wire fan connected. You may also need to increase the fan divisors. See doc/fan-divisors for more information. regards, Dirk

    Read the article

  • Lenovo Thinkpad L430 overheating due to fan problems

    - by Dirk B.
    This is the same question as Fan not working on thinkpad L430, laptop overheating, but that question has been marked as a duplicate, which it is not, and I cannot reopen it. I'm having problems controlling the fan of my Lenovo Thinkpad L430. The fan doesn't start. Without any fan control installed the fan just doesn't run. If I run stress, it does run a little, but it's nowhere near the speed it should be. After a while, the laptop just overheats and stops. I Tried to install tp-fancontrol, and enabled thinkpad_acpi fancontrol=1, but to no avail. If I try to set the fan speed manually, it doesn't start up. In windows, there's a program called TPFanControl. It turns out that this laptop uses a different scheme to control the fan than other thinkpads. The level runs from 0 to 255, and max = 0 and min=255. Now I'm looking for a fan control program that works for linux. Does anyone know if it actually exists? Anyone with any experience on fan control on a L430? Update: sudo pwmconfig gives the following output: # pwmconfig revision 5857 (2010-08-22) This program will search your sensors for pulse width modulation (pwm) controls, and test each one to see if it controls a fan on your motherboard. Note that many motherboards do not have pwm circuitry installed, even if your sensor chip supports pwm. We will attempt to briefly stop each fan using the pwm controls. The program will attempt to restore each fan to full speed after testing. However, it is ** very important ** that you physically verify that the fans have been to full speed after the program has completed. Found the following devices: hwmon0 is acpitz hwmon1/device is coretemp hwmon2/device is thinkpad Found the following PWM controls: hwmon2/device/pwm1 hwmon2/device/pwm1 is currently setup for automatic speed control. In general, automatic mode is preferred over manual mode, as it is more efficient and it reacts faster. Are you sure that you want to setup this output for manual control? (n) y Giving the fans some time to reach full speed... Found the following fan sensors: hwmon2/device/fan1_input current speed: 0 ... skipping! There are no working fan sensors, all readings are 0. Make sure you have a 3-wire fan connected. You may also need to increase the fan divisors. See doc/fan-divisors for more information. update: If you need it, lspci is available here

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Do glue records in non-circular dns-lookups speed up domain resolution or not?

    - by Joe Hopfgartner
    Doing a lookup for my domain on http://www.intodns.com/ I noticed theese two messages: In Parent section: DNS Parent sent Glue The parent nameserver g.gtld-servers.net is not sending out GLUE for every nameservers listed, meaning he is sending out your nameservers host names without sending the A records of those nameservers. It's ok but you have to know that this will require an extra A lookup that can delay a little the connections to your site. This happens a lot if you have nameservers on different TLD (domain.com for example with nameserver ns.domain.org.) and in NS section: Glue for NS records INFO: GLUE was not sent when I asked your nameservers for your NS records.This is ok but you should know that in this case an extra A record lookup is required in order to get the IPs of your NS records. The nameservers without glue are: 109.230.225.96 84.201.40.52 You can fix this for example by adding A records to your nameservers for the zones listed above. I do perfectly understand that the primary objective of glue records is to resolve circular dependencies. The classic use case: my domain is example.com and I want to have the nameserver ns1.example.com. This will never work because i cannot know the ip of ns1.example.com if I don't fetch example.com and in order to do that I need to fetch it from ns1.example.com. To resolve this deadlock I add a glue record to ns1.example.com containing the ip adress of the nameserver, so this can work out. So this problem does not occour if the nameservers are in a different TLD than the domain i want to look up. But however to fetch the zone information from the nameservers I need to know their ip adress right? And in order to know that i need to fetch the zone the nameservers are in from their respective nameservers, right? (or rather my ISP needs to do that in the background) So an extra lookup that takes time? If I now have glue records, I know the IP adress right away without the need to look it up - so this should speed up the resolution of my domain, shouldnt it? However my DNS zone provider (tecserver.at) replied that this would make no sense because "we are not running ns1.ourdomain.com an ns1.ourdomain.com as authorative NS for ourdomain.com. This would be the only sense for glue records. Tecserver has a glue record because the NS for tecserver.at are ns1.tecserver.at and ns2.tecserver.at. Therefore a glue record is needed for resolution.

    Read the article

  • How do I locate the app generating this network traffic?

    - by Christopher Bartels
    I don't know what this process is doing on my computer. I run Windows 7 Professional w/ all its updates running current non-free antivirus. I only see it in Resource Monitor, where you can see the Network Service process connected to bitum.nnov.ru. When my PC's network traffic generating apps are idle, this process is using the most of all the idle processes using the network. Screenshot hosted here: http://sss.proinbox.com/bitum-nnov-ru.jpg Does anyone recognize this? The page source mentions a control port & a stream port: Page Source for http://bitum.nnov.ru : <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN"> <html> <head> <title>DVR WebViewer</title> <meta http-equiv="Content-Type" content="text/html; charset=euc-kr"> </head> <body topmargin="0" leftmargin="0"> <OBJECT classid="clsid:EE479A40-C128-40DD-93DA-000556AF9607" codebase="CtrWeb.cab#version=1,0,2,2" width=875 height=585 align=center hspace=0 vspace=0 > <param name="CmdPort" value="5920"> <param name="StreamPort" value="5921"> </body> </html> When I google this page's title, I see a number of other domains that host the same page. Whois: domain: NNOV.RU nserver: ns.kis.ru. nserver: ns.nnov.ru. 78.25.80.210 nserver: ns1.kis.ru. nserver: ns2.kis.ru. state: REGISTERED, DELEGATED, VERIFIED org: "Agentstvo Delovoj Svjazi", Ltd registrar: RU-CENTER-REG-RIPN admin-contact: https://www.nic.ru/whois created: 1996.10.23 paid-till: 2012.11.01 free-date: 2012.12.02 source: TCI Last updated on 2012.06.16 04:20:46 MSK

    Read the article