Search Results

Search found 6531 results on 262 pages for 'ntvdm exe'.

Page 22/262 | < Previous Page | 18 19 20 21 22 23 24 25 26 27 28 29  | Next Page >

  • Windows 7 recreate my .exe/.dll files

    - by Anonymous
    hi, i have a few programs that check if file exist, and if its old version delete him and paste the new one. However under Windows 7 Professional i can't delete the file some System process is always restoring it (same with the dll files) and as you can imagine a lot of programs are crashing because of that behaviour. So WHAT SERVICE/PROCESS can lock/recreate/restore files? I have disabled System Recovery.

    Read the article

  • Start ProcessMonitor will unexpectedly execute another irrelevant exe

    - by zaexage
    Well, I have encountered a weird problem recently. Whenever I try to start ProcessMonitor, another irrelevant program (an IM software indeed) starts instead. In the end, the only way I start ProcessMonitor is to uninstall that IM software. I have tried ProcessMonitor on my colleagues' computers but none of them see the same things. So, do you guys have any idea how to solve this? Thanks in advance.

    Read the article

  • Corrupted Laptop - Transfer Data Without My Computer (explorer.exe) Using Command Line

    - by nicorellius
    I have a laptop (Toshiba Satellite) that is pretty messed up. The person this belongs too already replaced it with a new machine. My job is to transfer all her data from this machine to disk so that I can transfer it to her. She doesn't want to lose any data (understandably so). Any operation I attempted (i.e., double clicking on any folder icon, like My Documents, My Computer, etc) resulted din a complete crash. The only good news is that I can actually start and navigate around using the command line. Also, I can access the internet. I have a network, so if I can map the drives I can get this thing figured out (hopefully). Also, I tried a USB drive but I couldn't figure out how to access it from the command line. Two questions (I need to use the command line for these): How would I go about accessing the USB drive and how can I map the shared drives on my network so that I may cd to that directory for use of the copy command?

    Read the article

  • sqlserver.exe uses 100% CPU

    - by Markus
    I've created an application (asp.net) that once a day syncs an entire database through XML-files. The sync first creates an transaction and then clears the databases tables and then starts to parse and insert the new rows into the database. When all the parsing is complete it commits the transaction. This works fine on a SQL Server 2005 (on another machine), but on SQL Server 2005 Express, the process starts to use 100% CPU after a while, and as I log the inserts being made I can see that it just stops inserting. No exception, it just stops inserting. Anyone got any idea what this may be? I've previously run the syncronization on another sql 2005 express (also on another computer), and that worked. The server has only 2GB RAM, could this be the problem?

    Read the article

  • Configuring SQL Server Management Studio to use Windows Integrated Authentication &hellip; from non-

    - by Enrique Lima
    Did you know you can pass your Windows credentials to SQL Server even when working from a workstation that is not joined to a domain? Here is how … From Start, then click All Programs, find Microsoft SQL Server (version 2005 or 2008). Once there, do a right-click on SQL Server Management Studio, then click on Properties Now, follow below to modify the entry for Target: Now the real task (we will be using the runas command) … Modify the shortcut’s target as follows, and remember to replace <domain\user> with the values that correspond to your environment : x64 SQL Server 2008 C:\Windows\System32\runas.exe /user:<domain\user> /netonly "C:\Program Files (x86)\Microsoft SQL Server\100\Tools\binn\VSShell\Common7\IDE\Ssms.exe -nosplash" SQL Server 2005 C:\Windows\System32\runas.exe /user:<domain\user> /netonly "C:\Program Files (x86)\Microsoft SQL Server\90\Tools\binn\VSShell\Common7\IDE\SqlWb.exe -nosplash" x86 SQL Server 2008 C:\Windows\System32\runas.exe /user:<domain\user> /netonly "C:\Program Files\Microsoft SQL Server\100\Tools\binn\VSShell\Common7\IDE\Ssms.exe -nosplash" SQL Server 2005 C:\Windows\System32\runas.exe /user:<domain\user> /netonly "C:\Program Files\Microsoft SQL Server\90\Tools\binn\VSShell\Common7\IDE\SqlWb.exe -nosplash" Since we modified the shortcut, we will need to fix the icon for SSMS.  We will fix it by pressing the Change Icon… button and pointing to the original “icon” providers. It is the executables for SSMS that hold the icon information, so we need to point to … x64 SQL Server 2008 %ProgramFiles% (x86)\Microsoft SQL Server\100\Tools\Binn\VSShell\Common7\IDE\Ssms.exe SQL Server 2005 C:\Program Files (x86)\Microsoft SQL Server\90\Tools\binn\VSShell\Common7\IDE\SqlWb.exe x86 SQL Server 2008 %ProgramFiles%\Microsoft SQL Server\100\Tools\Binn\VSShell\Common7\IDE\Ssms.exe SQL Server 2005 C:\Program Files\Microsoft SQL Server\90\Tools\binn\VSShell\Common7\IDE\SqlWb.exe When you start SSMS from a modified shortcut, you’ll be prompted for your domain password: SSMS will show up stating a different account in the username box, but the parameters from the configuration you are doing above do work and will pass on correctly.

    Read the article

  • Encoding MP3 and adding VBR or Xing headers (with lame or another method)

    - by J. Pablo Fernández
    I'm writing a program that converts wavs to mp3s, so far, by using lame. It's generating a command line more or less like this: "c:\Program Files (x86)\Lame for Audacity\lame.exe" --preset fast medium in.wav out.mp3 The problem I'm having is that no VBR or Xing headers are written to the MP3. How can I make lame.exe write those headers? Should I use another program to write those headers (platform is Windows, .Net 3.5)? Should I use another program for MP3 encoding?

    Read the article

  • Encryption for Executable

    - by Farooq
    Can anyone recommend what's a good way to encrypt an executable? I was trying to use AxCrypt but I don't like the usage, i.e. you specify a passcode and the person who launches the exe needs to specify the passcode. Is there someway to encrypt it once and users just run the exe without specifying any passwords?

    Read the article

  • WiX 3: Using heat.exe to add bulk files to a new WiX project: HEAT5150

    - by Karen Kwong
    If this is a repeat question, please direct me to the existing solution. I wasn't able to find a matching query. We currently use InstallShield. I'm attempting to covert a project with 407 files to a WiX3 installation package. I tried using heat.exe to do some of the automation but I get the following warning for almost every file: c: heat dir "c:\projectDir\projectA" -gg -ke -template:Product -out "c:\install\projectA\heatOutput" heat.exe: warning HEAT5150 : Could not harvest data from a file that was expected to be a SelfReg DLL: c:\projectDir\projectA\plugin1.dll. If this file does not support SelfReg you can ignore this warning. Otherwise, this error detail may be helpful to diagnose the failure: Unable to load file: c:\projectDir\projectA\plugin1.dll, error: 126. Q: Is it normal for this warning to be reported for every file? If there's a current "How To create/convert to your first WiX install project with many files" tutorial, please point me to it. The key requirement is "with many files". Thank-you -Karen Kwong- PS. I know that WiX is designed for incremental install project creation but it would be nice to know if there's an automated way to convert existing install projects.

    Read the article

  • Task failed because "sgen.exe" was not found

    - by Kinze
    I am getting the following error when attempting to build my project in Visual Studio 2008 Professional Edition: *Task failed because “sgen.exe” was not found, or the correct Microsoft Windows SDK is not installed. The task is looking for “sgen.exe” in the “bin” subdirectory beneath the location specified in the InstallationFolder value of the registry key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Microsoft SDKs\Windows\v6.0A. You may be able to solve the problem by doing one of the following: 1) Install the Microsoft Windows SDK for Windows Server 2008 and .NET Framework 3.5. 2) Install Visual Studio 2008. 3) Manually set the above registry key to the correct location. 4) Pass the correct location into the “ToolPath” parameter of the task.* I tried downloading Microsoft Windows SDK for Windows Server 2008 and .NET Framework 3.5, and still get the error. I also tried downloading the Windows 7 SDK and .NET Framework 3.5 and still same result. I also tried to manually editing the registry to change the InstallationFolder and I tried repairing the Visual Studio install. The project was originally created on WinXP and I am trying to compile on a reformatted machine running Windows 7 Enterprise.

    Read the article

  • "Unrecognized configuration section connectionStrings" in app.exe.config

    - by Richard Bysouth
    Hi On a Terminal Server install of my WinForms app, one of my clients gets the following exception on startup: "Unrecognized configuration section connectionStrings" This is occurring in myapp.exe.config but I can't figure out why. Runs perfectly everywhere else, only difference between this install and any other is the connection string. I've searched around, but can only find this issue relating to ASP.NET apps and issues in web.config. Any ideas what could be broken in the config of this WinForms app though? Is it indicating a problem further up in machine.config? FYI the top part of myapp.exe.config is: <?xml version="1.0" encoding="utf-8"?> <configuration> <configSections> <sectionGroup name="applicationSettings" type="System.Configuration.ApplicationSettingsGroup, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=jjjjjjjjjj"> <section name="MyApp.Settings" type="System.Configuration.ClientSettingsSection, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=jjjjjjjj" requirePermission="false" /> </sectionGroup> <sectionGroup name="userSettings" type="System.Configuration.UserSettingsGroup, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=jjjjjjjjj"> <section name="MyApp.Settings" type="System.Configuration.ClientSettingsSection, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=jjjjjjjjjj" allowExeDefinition="MachineToLocalUser" requirePermission="false" /> </sectionGroup> </configSections> <connectionStrings> <add name="MyApp.DataAccessLayer.Settings.MyConnectionString" connectionString="$$$$$$" providerName="System.Data.SqlClient" /> </connectionStrings> ... thanks Richard

    Read the article

  • SubSonic missing stored procedures in StoredProcedures.cs when generated with SubCommander sonic.exe

    - by Mark
    We have been using SubSonic to generate our DAL with a lot of success on VS2005 and SubSonic Tools 2.0.3. SubSonic Tools do not work on VS2008 (as far as we can work out) so we have tried to use SubCommander\sonic.exe and are now hitting some problems. When we regenerate the project using SubCommander\sonic.exe and try to compile we get some errors reporting missing members (which should have been automatically generated based on the stored procedures we have). On closer inspection it looks like my StoredProcedures.cs file is missing some (not all) automatically generated methods for my classes. As an example, I have 2 procs: [dbo]._ClassA_Func1 [dbo]._ClassA_Func2 Only one of these is being generated in the StoredProcedures.cs file. These methods generate fine using the SubSonic Tools plugin. We have tried now with versions 2.1 and 2.2 of SubSonic with the same issue. We are still on .NET 2.0 so cannot use SubSonic 3.0. I have checked the permissions of both procs using fn_my_permissions and they seem identical. Does anyone have any ideas on what I can check? Thanks -- Mark

    Read the article

  • ASP.NET/C# - Deserialize XML, XSD.exe created multiple classes

    - by Barryman9000
    I'm trying to deserialize some XML (returned from a web service) into an object that I created using XSD.exe. The XSD executable created a .CS file with a different partial class for each parent node in the XML. For Example, the beginning of the XML looks like this (why can't I post xml here? sorry, this is ugly): <disclaimer><notificationDescription>Additional charges will apply.</notificationDescription></disclaimer><quote><masterQuote></masterQuote></quote> And the Class generated by the XSD.exe has a partial class named disclaimer with a get; set; string for notificationDescription. And another partial class for quoteMasterQuote with the corresponding child nodes as public strings. How can I deserialize this XML file into multiple classes? I found this code, but it seems like it'll only work for one object. public static PricingResponse2 DeSerialize(string _xml) { PricingResponse2 _resp = new PricingResponse2(); StringReader _strReader = new StringReader(_xml); XmlSerializer _serializer = new XmlSerializer(_resp.GetType()); XmlReader _xmlReader = new XmlTextReader(_strReader); try { _resp = (PricingResponse2)_serializer.Deserialize(_xmlReader); return _resp; } catch (Exception ex) { string _error = ex.Message; throw; } finally { _xmlReader.Close(); _strReader.Close(); _strReader.Dispose(); } } This is the first time I've tried this, so I'm a little lost.

    Read the article

  • How to print PDF on default network printer using GhostScript (gswin32c.exe) shell command

    - by Maciej
    I'd like to print PDF file(s) on windows' network printer via GhostScript. (I dont want to use Adobe Reader) I've read gswin32c.exe which can do the job. I experimented with many commands and coudn't find the way how to force gs to print PDF on my (windows default) network drive. I don't need point exact network printer- default can be used. But if there is no such option I'm happy to pass printer name as well. (I've tried with param -SDevice="\server_IP\printer_name" but this didnt work as well...) Command working under Windows cmd: gswin32c -dPrinted -dBATCH -dNOPAUSE -dNOSAFER -q -dNumCopies=1 -sDEVICE=ljet4 -sOutputFile="\\spool\\\Server_Name\Printer_name" "C:\test.pdf" Method created base on above - doesnt work and thorws exception. (Error code = 1) /// <summary> /// Prints the PDF. /// </summary> /// <param name="ghostScriptPath">The ghost script path. Eg "C:\Program Files\gs\gs8.71\bin\gswin32c.exe"</param> /// <param name="numberOfCopies">The number of copies.</param> /// <param name="printerName">Name of the printer. Eg \\server_name\printer_name</param> /// <param name="pdfFileName">Name of the PDF file.</param> /// <returns></returns> public bool PrintPDF (string ghostScriptPath, int numberOfCopies, string printerName, string pdfFileName) { ProcessStartInfo startInfo = new ProcessStartInfo(); startInfo.Arguments = " -dPrinted -dBATCH -dNOPAUSE -dNOSAFER -q -dNumCopies=" + Convert.ToString(numberOfCopies) + " -sDEVICE=ljet4 -sOutputFile=\"\\\\spool\\" + printerName + "\" \"" + pdfFileName + "\""; startInfo.FileName = ghostScriptPath; startInfo.UseShellExecute = false; Process process = Process.Start(startInfo); return process.ExitCode == 0; } Any idea how to make it working under C#?

    Read the article

  • Setup.exe files downloading without cab files over poor connections

    - by Colin
    We have customers who are trying to download a setup.exe file over mobile connections that appear to be very slow. They have reported that when they click on the downloaded setup.exe, the install wizard starts up, but part way through the wizard they get an error message indicating that a cab file is corrupt or missing. They couriered a problem tablet to us, and we downloaded the file without a problem but I could replicate the problem by using https to download the file (https is normally used to access the rest of the site, although it is not necessary for the download). When I did this the downloaded file was 2.8MB. It should be 8MB. I don't think that https is the root cause of the problem because I can see the download link in the browser history using http, so I know the customer tried to download using http. I think that the issue is that the poor connection is preventing a complete download, but the browser is acting as if it is complete. Is there a way to ensure the file is downloaded fully, or not at all? Why does the browser not indicate that the download is incomplete?

    Read the article

  • Generate exe in .Net

    - by rwallace
    In .Net, you can generate byte code in memory, and presumably save the resulting program to a .exe file. To do the first step, I have the following test code adapted from http://www.code-magazine.com/Article.aspx?quickid=0301051 var name = new AssemblyName(); name.Name = "MyAssembly"; var ad = Thread.GetDomain(); var ab = ad.DefineDynamicAssembly(name, AssemblyBuilderAccess.Run); var mb = ab.DefineDynamicModule("MyModule"); var theClass = mb.DefineType("MathOps", TypeAttributes.Public); var retType = typeof(System.Int32); var parms = new Type[2]; parms[0] = typeof(System.Int32); parms[1] = typeof(System.Int32); var meb = theClass.DefineMethod("ReturnSum", MethodAttributes.Public, retType, parms); var gen = meb.GetILGenerator(); gen.Emit(OpCodes.Ldarg_1); gen.Emit(OpCodes.Ldarg_2); gen.Emit(OpCodes.Add_Ovf); gen.Emit(OpCodes.Stloc_0); gen.Emit(OpCodes.Br_S); gen.Emit(OpCodes.Ldloc_0); gen.Emit(OpCodes.Ret); theClass.CreateType(); How do you do the second step, and save the result to a .exe?

    Read the article

  • Network Authentication when running exe from WMI

    - by Andy
    Hi, I have a C# exe that needs to be run using WMI and access a network share. However, when I access the share I get an UnauthorizedAccessException. If I run the exe directly the share is accessible. I am using the same user account in both cases. There are two parts to my application, a GUI client that runs on a local PC and a backend process that runs on a remote PC. When the client needs to connect to the backend it first launches the remote process using WMI (code reproduced below). The remote process does a number of things including accessing a network share using Directory.GetDirectories() and reports back to the client. When the remote process is launched automatically by the client using WMI, it cannot access the network share. However, if I connect to the remote machine using Remote Desktop and manually launch the backend process, access to the network share succeeds. The user specifed in the WMI call and the user logged in for the Remote Desktop session are the same, so the permissions should be the same, shouldn't they? I see in the MSDN entry for Directory.Exists() it states "The Exists method does not perform network authentication. If you query an existing network share without being pre-authenticated, the Exists method will return false." I assume this is related? How can I ensure the user is authenticated correctly in a WMI session? ConnectionOptions opts = new ConnectionOptions(); opts.Username = username; opts.Password = password; ManagementPath path = new ManagementPath(string.Format("\\\\{0}\\root\\cimv2:Win32_Process", remoteHost)); ManagementScope scope = new ManagementScope(path, opts); scope.Connect(); ObjectGetOptions getOpts = new ObjectGetOptions(); using (ManagementClass mngClass = new ManagementClass(scope, path, getOpts)) { ManagementBaseObject inParams = mngClass.GetMethodParameters("Create"); inParams["CommandLine"] = commandLine; ManagementBaseObject outParams = mngClass.InvokeMethod("Create", inParams, null); }

    Read the article

  • Text piped to PowerShell.exe isn't recieved when using [Console]::ReadLine()

    - by crtracy
    I'm getting itermittent data loss when calling .NET [Console]::ReadLine() to read piped input to PowerShell.exe: >ping localhost | powershell -NonInteractive -NoProfile -C "do {$line = [Console]::ReadLine(); ('' + (Get-Date -f 'HH:mm :ss') + $line) | Write-Host; } while ($line -ne $null)" 23:56:45time<1ms 23:56:45 23:56:46time<1ms 23:56:46 23:56:47time<1ms 23:56:47 23:56:47 Normally 'ping localhost' from Vista64 looks like this, so there is a lot of data missing from the output above: Pinging WORLNTEC02.bnysecurities.corp.local [::1] from ::1 with 32 bytes of data: Reply from ::1: time<1ms Reply from ::1: time<1ms Reply from ::1: time<1ms Reply from ::1: time<1ms Ping statistics for ::1: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms But using the same API from C# recieves all the data sent to the process (excluding some newline differences). Code: namespace ConOutTime { class Program { static void Main (string[] args) { string s; while ((s = Console.ReadLine ()) != null) { if (s.Length > 0) // don't write time for empty lines Console.WriteLine("{0:HH:mm:ss} {1}", DateTime.Now, s); } } } } Output: 00:44:30 Pinging WORLNTEC02.bnysecurities.corp.local [::1] from ::1 with 32 bytes of data: 00:44:30 Reply from ::1: time<1ms 00:44:31 Reply from ::1: time<1ms 00:44:32 Reply from ::1: time<1ms 00:44:33 Reply from ::1: time<1ms 00:44:33 Ping statistics for ::1: 00:44:33 Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), 00:44:33 Approximate round trip times in milli-seconds: 00:44:33 Minimum = 0ms, Maximum = 0ms, Average = 0ms So, if calling the same API from PowerShell instead of C# many parts of StdIn get 'eaten'. Is the PowerShell host reading string from StdIn even though I didn't use 'PowerShell.exe -Command -'?

    Read the article

  • Ways to access a 32bit DLL from a 64bit exe

    - by bufferz
    I have a project that must be compiled and run in 64 bit mode. Unfortunately, I am required to call upon a DLL that is only available in 32 bit mode, so there's no way I can house everything in a 1 Visual Studio project. I am working to find the best way to wrap the 32 bit DLL in its own exe/service and issue remote (although on the same machine) calls to that exe/service from my 64 bit app. My OS is Win7 Pro 64 bit. The required calls to this 32 bit process are several dozen per second, but low data volume. This is a realtime image analysis application so response time is critical despite low volume. Lots of sending/receiving single primitives. Ideally, I would host a WCF service to house this DLL, but in a 64 bit OS one cannot force the service to run as x86! Source. That is really unfortunate since I timed function calls to the WCF service to be only 4ms on my machine. I have experimented with named pipes is .net. I found them to be 40-50 times slower than WCF (unusable for me). Any other options or suggestions for the best way to approach my puzzle?

    Read the article

  • MySQL problem reconnecting (mysqld.exe) keeps giving error...

    - by Ronedog
    Need some guidance figuring out what went wrong. I've been using mysql, phpmyadmin for just under a year on my home computer while I develop a webapp. 3 days ago I updated my windows vista with all the "wonderful" microsoft updates, security patches, etc...and now it's broke. I tried uninstalling all the upgrades, but there are 4 of them I can't unistall because microsoft says their "operating system" updates and can't be unistalled. My system is: windows vista, php 5+, mysql 5.1, Apache 2+. I can run my web app and it queries the database without any problems. However, when I run phpmyadmin to get into the database I get an error: "mysqld.exe has stopped working" and phpmyadmin crashes. I tried going to the command line for mysql to do a mysqldump to backup my database and it gives me an error "2013, could not connect to the server". If I restart the computer the webapp will work again. Basically, php can query the database, but if I try to get at the database through phpmyadmin, or the command prompt the mysqld.exe error occurs and blows mysql out. Any ideas what's going on here? Any ideas how to get around this to backup the db, so I can reinstall mysql?. I'm really lost where to start. I don't really know if the updates caused the problem, or if the 4 updates that can't be unistalled are really the problem. Any tips will be appreciated. thanks.

    Read the article

  • FileVersionInfo.GetVersionInfo getting old version of an exe swapped at runtime

    - by Richard
    I have a program executing in c# that is sometimes updated while it is running by swapping the exe to a new one. I want the program to routinely check if it has been updated and if so, restart. I use the following function to do this. public static bool DoINeedToRestart(string exe_name) { Version cur_version = new Version(MainProgram.StartVersion); Version file_version = new Version(GetProductVersion(exe_name)); MessageBox.Show("Comparing cur_version " + cur_version.ToString() + " with " + file_version.ToString()); if (file_version > cur_version) { return true; } return false; } public static string GetProductVersion(string path_name) { FileVersionInfo myFI = FileVersionInfo.GetVersionInfo(path_name); return myFI.FileVersion; } MainProgram.StartVersion is set when the program is started to be the current version using the GetProductVersion(exe_name) exe_name is set to be the name of the executable that is being updated. The problem I have is once the MainProgram.exe file has been updated (I verify this manually by looking at the file properties and checking the file version), the GetProductVersion still returns the old file version and I have no idea why! Any help is greatly appreciated.

    Read the article

  • c# getting file version of a swapped exe at runtime

    - by Richard
    I have a program executing in c# that is sometimes updated while it is running by swapping the exe to a new one. I want the program to routinely check if it has been updated and if so, restart. I use the following function to do this. public static bool DoINeedToRestart(string exe_name) { Version cur_version = new Version(MainProgram.StartVersion); Version file_version = new Version(GetProductVersion(exe_name)); MessageBox.Show("Comparing cur_version " + cur_version.ToString() + " with " + file_version.ToString()); if (file_version > cur_version) { return true; } return false; } public static string GetProductVersion(string path_name) { FileVersionInfo myFI = FileVersionInfo.GetVersionInfo(path_name); return myFI.FileVersion; } StartVersion is set when the program is started to be the current version using the GetProductVersion(exe_name). exe_name is set to be the name of the executable that is being updated. The problem I have is once the MainProgram.exe file has been updated (I verify this manually by looking at the file properties and checking the file version), the GetProductVersion still returns the old file version and I have no idea why! Any help is greatly appreciated.

    Read the article

  • An easy way to create Side by Side registrationless COM Manifests with Visual Studio

    - by Rick Strahl
    Here's something I didn't find out until today: You can use Visual Studio to easily create registrationless COM manifest files for you with just a couple of small steps. Registrationless COM lets you use COM component without them being registered in the registry. This means it's possible to deploy COM components along with another application using plain xcopy semantics. To be sure it's rarely quite that easy - you need to watch out for dependencies - but if you know you have COM components that are light weight and have no or known dependencies it's easy to get everything into a single folder and off you go. Registrationless COM works via manifest files which carry the same name as the executable plus a .manifest extension (ie. yourapp.exe.manifest) I'm going to use a Visual FoxPro COM object as an example and create a simple Windows Forms app that calls the component - without that component being registered. Let's take a walk down memory lane… Create a COM Component I start by creating a FoxPro COM component because that's what I know and am working with here in my legacy environment. You can use VB classic or C++ ATL object if that's more to your liking. Here's a real simple Fox one: DEFINE CLASS SimpleServer as Session OLEPUBLIC FUNCTION HelloWorld(lcName) RETURN "Hello " + lcName ENDDEFINE Compile it into a DLL COM component with: BUILD MTDLL simpleserver FROM simpleserver RECOMPILE And to make sure it works test it quickly from Visual FoxPro: server = CREATEOBJECT("simpleServer.simpleserver") MESSAGEBOX( server.HelloWorld("Rick") ) Using Visual Studio to create a Manifest File for a COM Component Next open Visual Studio and create a new executable project - a Console App or WinForms or WPF application will all do. Go to the References Node Select Add Reference Use the Browse tab and find your compiled DLL to import  Next you'll see your assembly in the project. Right click on the reference and select Properties Click on the Isolated DropDown and select True Compile and that's all there's to it. Visual Studio will create a App.exe.manifest file right alongside your application's EXE. The manifest file created looks like this: xml version="1.0" encoding="utf-8"? assembly xsi:schemaLocation="urn:schemas-microsoft-com:asm.v1 assembly.adaptive.xsd" manifestVersion="1.0" xmlns:asmv1="urn:schemas-microsoft-com:asm.v1" xmlns:asmv2="urn:schemas-microsoft-com:asm.v2" xmlns:asmv3="urn:schemas-microsoft-com:asm.v3" xmlns:dsig="http://www.w3.org/2000/09/xmldsig#" xmlns:co.v1="urn:schemas-microsoft-com:clickonce.v1" xmlns:co.v2="urn:schemas-microsoft-com:clickonce.v2" xmlns="urn:schemas-microsoft-com:asm.v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" asmv2:size="27293" hash xmlns="urn:schemas-microsoft-com:asm.v2" dsig:Transforms dsig:Transform Algorithm="urn:schemas-microsoft-com:HashTransforms.Identity" / dsig:Transforms dsig:DigestMethod Algorithm="http://www.w3.org/2000/09/xmldsig#sha1" / dsig:DigestValuepuq+ua20bbidGOWhPOxfquztBCU=dsig:DigestValue hash typelib tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" version="1.0" helpdir="" resourceid="0" flags="HASDISKIMAGE" / comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file assembly Now let's finish our super complex console app to test with: using System; using System.Collections.Generic; using System.Text; namespace ConsoleApplication1 {     class Program     {         static voidMain(string[] args)         { Type type = Type.GetTypeFromProgID("simpleserver.simpleserver",true); dynamic server = Activator.CreateInstance(type); Console.WriteLine(server.HelloWorld("rick")); Console.ReadLine(); } } } Now run the Console Application… As expected that should work. And why not? The COM component is still registered, right? :-) Nothing tricky about that. Let's unregister the COM component and then re-run and see what happens. Go to the Command Prompt Change to the folder where the DLL is installed Unregister with: RegSvr32 -u simpleserver.dll      To be sure that the COM component no longer works, check it out with the same test you used earlier (ie. o = CREATEOBJECT("SimpleServer.SimpleServer") in your development environment or VBScript etc.). Make sure you run the EXE and you don't re-compile the application or else Visual Studio will complain that it can't find the COM component in the registry while compiling. In fact now that we have our .manifest file you can remove the COM object from the project. When you run run the EXE from Windows Explorer or a command prompt to avoid the recompile. Watch out for embedded Manifest Files Now recompile your .NET project and run it… and it will most likely fail! The problem is that .NET applications by default embeds a manifest file into the compiled EXE application which results in the externally created manifest file being completely ignored. Only one manifest can be applied at a time and the compiled manifest takes precedency. Uh, thanks Visual Studio - not very helpful… Note that if you use another development tool like Visual FoxPro to create your EXE this won't be an issue as long as the tool doesn't automatically add a manifest file. Creating a Visual FoxPro EXE for example will work immediately with the generated manifest file as is. If you are using .NET and Visual Studio you have a couple of options of getting around this: Remove the embedded manifest file Copy the contents of the generated manifest file into a project manifest file and compile that in To remove an embedded manifest in a Visual Studio project: Open the Project Properties (Alt-Enter on project node) Go down to Resources | Manifest and select | Create Application without a Manifest   You can now add use the external manifest file and it will actually be respected when the app runs. The other option is to let Visual Studio create the manifest file on disk and then explicitly add the manifest file into the project. Notice on the dialog above I did this for app.exe.manifest and the manifest actually shows up in the list. If I select this file it will be compiled into the EXE and be used in lieu of any external files and that works as well. Remove the simpleserver.dll reference so you can compile your code and run the application. Now it should work without COM registration of the component. Personally I prefer external manifests because they can be modified after the fact - compiled manifests are evil in my mind because they are immutable - once they are there they can't be overriden or changed. So I prefer an external manifest. However, if you are absolutely sure nothing needs to change and you don't want anybody messing with your manifest, you can also embed it. The option to either is there. Watch for Manifest Caching While working trying to get this to work I ran into some problems at first. Specifically when it wasn't working at first (due to the embedded schema) I played with various different manifest layouts in different files etc.. There are a number of different ways to actually represent manifest files including offloading to separate folder (more on that later). A few times I made deliberate errors in the schema file and I found that regardless of what I did once the app failed or worked no amount of changing of the manifest file would make it behave differently. It appears that Windows is caching the manifest data for a given EXE or DLL. It takes a restart or a recompile of either the EXE or the DLL to clear the caching. Recompile your servers in order to see manifest changes unless there's an outright failure of an invalid manifest file. If the app starts the manifest is being read and caches immediately. This can be very confusing especially if you don't know that it's happening. I found myself always recompiling the exe after each run and before making any changes to the manifest file. Don't forget about Runtimes of COM Objects In the example I used above I used a Visual FoxPro COM component. Visual FoxPro is a runtime based environment so if I'm going to distribute an application that uses a FoxPro COM object the runtimes need to be distributed as well. The same is true of classic Visual Basic applications. Assuming that you don't know whether the runtimes are installed on the target machines make sure to install all the additional files in the EXE's directory alongside the COM DLL. In the case of Visual FoxPro the target folder should contain: The EXE  App.exe The Manifest file (unless it's compiled in) App.exe.manifest The COM object DLL (simpleserver.dll) Visual FoxPro Runtimes: VFP9t.dll (or VFP9r.dll for non-multithreaded dlls), vfp9rENU.dll, msvcr71.dll All these files should be in the same folder. Debugging Manifest load Errors If you for some reason get your manifest loading wrong there are a couple of useful tools available - SxSTrace and SxSParse. These two tools can be a huge help in debugging manifest loading errors. Put the following into a batch file (SxS_Trace.bat for example): sxstrace Trace -logfile:sxs.bin sxstrace Parse -logfile:sxs.bin -outfile:sxs.txt Then start the batch file before running your EXE. Make sure there's no caching happening as described in the previous section. For example, if I go into the manifest file and explicitly break the CLSID and/or ProgID I get a detailed report on where the EXE is looking for the manifest and what it's reading. Eventually the trace gives me an error like this: INFO: Parsing Manifest File C:\wwapps\Conf\SideBySide\Code\app.EXE.     INFO: Manifest Definition Identity is App.exe,processorArchitecture="x86",type="win32",version="1.0.0.0".     ERROR: Line 13: The value {AAaf2c2811-0657-4264-a1f5-06d033a969ff} of attribute clsid in element comClass is invalid. ERROR: Activation Context generation failed. End Activation Context Generation. pinpointing nicely where the error lies. Pay special attention to the various attributes - they have to match exactly in the different sections of the manifest file(s). Multiple COM Objects The manifest file that Visual Studio creates is actually quite more complex than is required for basic registrationless COM object invokation. The manifest file can be simplified a lot actually by stripping off various namespaces and removing the type library references altogether. Here's an example of a simplified manifest file that actually includes references to 2 COM servers: xml version="1.0" encoding="utf-8"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name = "sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" threadingModel="apartment" / file assembly Simple enough right? Routing to separate Manifest Files and Folders In the examples above all files ended up in the application's root folder - all the DLLs, support files and runtimes. Sometimes that's not so desirable and you can actually create separate manifest files. The easiest way to do this is to create a manifest file that 'routes' to another manifest file in a separate folder. Basically you create a new 'assembly identity' via a named id. You can then create a folder and another manifest with the id plus .manifest that points at the actual file. In this example I create: App.exe.manifest A folder called App.deploy A manifest file in App.deploy All DLLs and runtimes in App.deploy Let's start with that master manifest file. This file only holds a reference to another manifest file: App.exe.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / dependency dependentAssembly assemblyIdentity name="App.deploy" version="1.0.0.0" type="win32" / dependentAssembly dependency assembly   Note this file only contains a dependency to App.deploy which is another manifest id. I can then create App.deploy.manifest in the current folder or in an App.deploy folder. In this case I'll create App.deploy and in it copy the DLLs and support runtimes. I then create App.deploy.manifest. App.deploy.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.deploy" type="win32" version="1.0.0.0" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name="sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" threadingModel="Apartment" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" / file assembly   In this manifest file I then host my COM DLLs and any support runtimes. This is quite useful if you have lots of DLLs you are referencing or if you need to have separate configuration and application files that are associated with the COM object. This way the operation of your main application and the COM objects it interacts with is somewhat separated. You can see the two folders here:   Routing Manifests to different Folders In theory registrationless COM should be pretty easy in painless - you've seen the configuration manifest files and it certainly doesn't look very complicated, right? But the devil's in the details. The ActivationContext API (SxS - side by side activation) is very intolerant of small errors in the XML or formatting of the keys, so be really careful when setting up components, especially if you are manually editing these files. If you do run into trouble SxsTrace/SxsParse are a huge help to track down the problems. And remember that if you do have problems that you'll need to recompile your EXEs or DLLs for the SxS APIs to refresh themselves properly. All of this gets even more fun if you want to do registrationless COM inside of IIS :-) But I'll leave that for another blog post…© Rick Strahl, West Wind Technologies, 2005-2011Posted in COM  .NET  FoxPro   Tweet (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • Sharepoint Error: [COMException (0x80004005): Cannot complete this action.

    - by ifunky
    Hi, I've created a site basic definition that uses different master and default pages. Everything works quite well except for whenever I create a new site based on the definition I receive the following error when browsing to the new site: [COMException (0x80004005): Cannot complete this action. Please try again.] Please try again.] Microsoft.SharePoint.Library.SPRequestInternalClass.GetFileAndMetaInfo(String bstrUrl, Byte bPageView, Byte bPageMode, Byte bGetBuildDependencySet, String bstrCurrentFolderUrl, Boolean& pbCanCustomizePages, Boolean& pbCanPersonalizeWebParts, Boolean& pbCanAddDeleteWebParts, Boolean& pbGhostedDocument, Boolean& pbDefaultToPersonal, String& pbstrSiteRoot, Guid& pgSiteId, UInt32& pdwVersion, String& pbstrTimeLastModified, String& pbstrContent, Byte& pVerGhostedSetupPath, UInt32& pdwPartCount, Object& pvarMetaData, Object& pvarMultipleMeetingDoclibRootFolders, String& pbstrRedirectUrl, Boolean& pbObjectIsList, Guid& pgListId, UInt32& pdwItemId, Int64& pllListFlags, Boolean& pbAccessDenied, Guid& pgDocId, Byte& piLevel, UInt64& ppermMask, Object& pvarBuildDependencySet, UInt32& pdwNumBuildDependencies, Object& pvarBuildDependencies, String& pbstrFolderUrl, String& pbstrContentTypeOrder) +0 Microsoft.SharePoint.Library.SPRequest.GetFileAndMetaInfo(String bstrUrl, Byte bPageView, Byte bPageMode, Byte bGetBuildDependencySet, String bstrCurrentFolderUrl, Boolean& pbCanCustomizePages, Boolean& pbCanPersonalizeWebParts, Boolean& pbCanAddDeleteWebParts, Boolean& pbGhostedDocument, Boolean& pbDefaultToPersonal, String& pbstrSiteRoot, Guid& pgSiteId, UInt32& pdwVersion, String& pbstrTimeLastModified, String& pbstrContent, Byte& pVerGhostedSetupPath, UInt32& pdwPartCount, Object& pvarMetaData, Object& pvarMultipleMeetingDoclibRootFolders, String& pbstrRedirectUrl, Boolean& pbObjectIsList, Guid& pgListId, UInt32& pdwItemId, Int64& pllListFlags, Boolean& pbAccessDenied, Guid& pgDocId, Byte& piLevel, UInt64& ppermMask, Object& pvarBuildDependencySet, UInt32& pdwNumBuildDependencies, Object& pvarBuildDependencies, String& pbstrFolderUrl, String& pbstrContentTypeOrder) +219 [SPException: Cannot complete this action. Please try again.] I'm able to work around this by checking out the new master page and checking it back in again and after doing so there are no further issues at all. Any ideas to what could cause this? Thanks Dan ONET.XML module section: <Modules> <Module Name="CustomMasterPage" List="116" Url="_catalogs/masterpage" RootWebOnly="FALSE"> <File Url="Shoes.master" Type="GhostableInLibrary" IgnoreIfAlreadyExists="TRUE" /> </Module> <Module Name="Default" List="116" Url=""> <File Url="default.aspx" Name="default.aspx" NavBarHome="True" IgnoreIfAlreadyExists="FALSE"> <AllUsersWebPart WebPartZoneID="Left" WebPartOrder="1"> &lt;webParts&gt;&lt;webPart xmlns="http://schemas.microsoft.com/WebPart/v3"&gt;&lt;metaData&gt;&lt;type name="BCM.SharePoint.Shoes.ShoesComponents.FooterLinks, BCM.SharePoint.Shoes.ShoesComponents, Version=1.0.0.0, Culture=neutral, PublicKeyToken=2881713f39360b71" /&gt;&lt;importErrorMessage&gt;Cannot import this Web Part.&lt;/importErrorMessage&gt;&lt;/metaData&gt;&lt;data&gt;&lt;properties&gt;&lt;property name="AllowClose" type="bool"&gt;True&lt;/property&gt;&lt;property name="Width" type="string" /&gt;&lt;property name="MyProperty" type="string"&gt;Hello SharePoint&lt;/property&gt;&lt;property name="AllowMinimize" type="bool"&gt;True&lt;/property&gt;&lt;property name="AllowConnect" type="bool"&gt;True&lt;/property&gt;&lt;property name="ChromeType" type="chrometype"&gt;None&lt;/property&gt;&lt;property name="TitleIconImageUrl" type="string"&gt;/_layouts/images/BCM_SharePoint_Shoes/wp_FooterLinks.gif&lt;/property&gt;&lt;property name="Description" type="string"&gt;FooterLinks Description&lt;/property&gt;&lt;property name="Hidden" type="bool"&gt;False&lt;/property&gt;&lt;property name="TitleUrl" type="string" /&gt;&lt;property name="AllowEdit" type="bool"&gt;True&lt;/property&gt;&lt;property name="Height" type="string" /&gt;&lt;property name="MissingAssembly" type="string"&gt;Cannot import this Web Part.&lt;/property&gt;&lt;property name="HelpUrl" type="string" /&gt;&lt;property name="Title" type="string" /&gt;&lt;property name="CatalogIconImageUrl" type="string"&gt;/_layouts/images/BCM_SharePoint_Shoes/wp_FooterLinks.gif&lt;/property&gt;&lt;property name="Direction" type="direction"&gt;NotSet&lt;/property&gt;&lt;property name="ChromeState" type="chromestate"&gt;Normal&lt;/property&gt;&lt;property name="AllowZoneChange" type="bool"&gt;True&lt;/property&gt;&lt;property name="AllowHide" type="bool"&gt;True&lt;/property&gt;&lt;property name="HelpMode" type="helpmode"&gt;Modeless&lt;/property&gt;&lt;property name="ExportMode" type="exportmode"&gt;All&lt;/property&gt;&lt;/properties&gt;&lt;/data&gt;&lt;/webPart&gt;&lt;/webParts&gt; </AllUsersWebPart> <AllUsersWebPart WebPartZoneID="Left" WebPartOrder="0"> &lt;webParts&gt;&lt;webPart xmlns="http://schemas.microsoft.com/WebPart/v3"&gt;&lt;metaData&gt;&lt;type name="BCM.SharePoint.Shoes.ShoesComponents.SubFooterLinks, BCM.SharePoint.Shoes.ShoesComponents, Version=1.0.0.0, Culture=neutral, PublicKeyToken=2881713f39360b71" /&gt;&lt;importErrorMessage&gt;Cannot import this Web Part.&lt;/importErrorMessage&gt;&lt;/metaData&gt;&lt;data&gt;&lt;properties&gt;&lt;property name="AllowClose" type="bool"&gt;True&lt;/property&gt;&lt;property name="Width" type="string" /&gt;&lt;property name="MyProperty" type="string"&gt;Hello SharePoint&lt;/property&gt;&lt;property name="AllowMinimize" type="bool"&gt;True&lt;/property&gt;&lt;property name="AllowConnect" type="bool"&gt;True&lt;/property&gt;&lt;property name="ChromeType" type="chrometype"&gt;None&lt;/property&gt;&lt;property name="TitleIconImageUrl" type="string"&gt;/_layouts/images/BCM_SharePoint_Shoes/wp_SubFooterLinks.gif&lt;/property&gt;&lt;property name="Description" type="string"&gt;Shoes home page links (under the hero image)&lt;/property&gt;&lt;property name="Hidden" type="bool"&gt;False&lt;/property&gt;&lt;property name="TitleUrl" type="string" /&gt;&lt;property name="AllowEdit" type="bool"&gt;True&lt;/property&gt;&lt;property name="Height" type="string" /&gt;&lt;property name="MissingAssembly" type="string"&gt;Cannot import this Web Part.&lt;/property&gt;&lt;property name="HelpUrl" type="string" /&gt;&lt;property name="Title" type="string" /&gt;&lt;property name="CatalogIconImageUrl" type="string"&gt;/_layouts/images/BCM_SharePoint_Shoes/wp_SubFooterLinks.gif&lt;/property&gt;&lt;property name="Direction" type="direction"&gt;NotSet&lt;/property&gt;&lt;property name="ChromeState" type="chromestate"&gt;Normal&lt;/property&gt;&lt;property name="AllowZoneChange" type="bool"&gt;True&lt;/property&gt;&lt;property name="AllowHide" type="bool"&gt;True&lt;/property&gt;&lt;property name="HelpMode" type="helpmode"&gt;Modeless&lt;/property&gt;&lt;property name="ExportMode" type="exportmode"&gt;All&lt;/property&gt;&lt;/properties&gt;&lt;/data&gt;&lt;/webPart&gt;&lt;/webParts&gt; </AllUsersWebPart> <NavBarPage Name="$Resources:core,nav_Home;" ID="1002" Position="Start" /> <NavBarPage Name="$Resources:core,nav_Home;" ID="0" Position="Start" /> </File> </Module> </Modules> LOG OUTPUT: 05/21/2010 12:22:55.11 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 72nz Medium Videntityinfo::isFreshToken reported failure. 05/21/2010 12:22:55.19 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services Fields 88yv Medium Creating default lists 05/21/2010 12:22:55.19 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 72lp Medium Creating directory Lists 05/21/2010 12:22:55.26 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services Fields 88yf Medium Creating list "Master Page Gallery" in web "http://mmm-dev-ll/sites/Shoes/test" at URL "_catalogs/masterpage", (setuppath: "C:\Program Files\Common Files\Microsoft Shared\Web Server Extensions\12\Template\global\lists\mplib") 05/21/2010 12:22:55.28 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services Fields 88y1 Medium No document templates uploaded for list "Master Page Gallery" -- none found for list template "100". 05/21/2010 12:22:55.28 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 72kc Medium Failed to find generic XML file at "C:\Program Files\Common Files\Microsoft Shared\Web Server Extensions\12\Template\xml\onet.xml", falling back to global site definition. 05/21/2010 12:22:56.22 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services Fields 88yz Medium Creating default modules at URL "http://mmm-dev-ll/sites/Shoes/test" 05/21/2010 12:22:56.22 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 8e27 Medium Ensuring module folder _catalogs/masterpage 05/21/2010 12:22:56.89 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 72h7 Medium Applying template "SubSite#1" to web at URL "http://mmm-dev-ll/sites/Shoes/test". 05/21/2010 12:22:57.09 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services Fields 88yy Medium Activating web-scoped features for template "SubSite#1" at URL "http://mmm-dev-ll/sites/Shoes/test" 05/21/2010 12:22:57.12 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 8l1c Medium Preparing 20 features for activation 05/21/2010 12:22:57.14 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 8l1d Medium Feature Activation: Batch Activating Features at URL http://mmm-dev-ll/sites/Shoes/test 'AnnouncementsList' (ID: '00bfea71-d1ce-42de-9c63-a44004ce0104'), 'ContactsList' (ID: '00bfea71-7e6d-4186-9ba8-c047ac750105'), 'CustomList' (ID: '00bfea71-de22-43b2-a848-c05709900100'), 'DataSourceLibrary' (ID: '00bfea71-f381-423d-b9d1-da7a54c50110'), 'DiscussionsList' (ID: '00bfea71-6a49-43fa-b535-d15c05500108'), 'DocumentLibrary' (ID: '00bfea71-e717-4e80-aa17-d0c71b360101'), 'EventsList' (ID: '00bfea71-ec85-4903-972d-ebe475780106'), 'GanttTasksList' (ID: '00bfea71-513d-4ca0-96c2-6a47775c0119'), 'GridList' (ID: '00bfea71-3a1d-41d3-a0ee-651d11570120'), 'IssuesList' (ID: '00bfea71-5932-4f9c-ad71-1557e5751100'), 'LinksList' (ID: '00bfea71-2062-426c-90bf-714c59600103'), 'NoCodeWorkflowLibrary' (ID: '00bfe... 05/21/2010 12:22:57.14* w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 8l1d Medium ...a71-f600-43f6-a895-40c0de7b0117'), 'PictureLibrary' (ID: '00bfea71-52d4-45b3-b544-b1c71b620109'), 'SurveysList' (ID: '00bfea71-eb8a-40b1-80c7-506be7590102'), 'TasksList' (ID: '00bfea71-a83e-497e-9ba0-7a5c597d0107'), 'WebPageLibrary' (ID: '00bfea71-c796-4402-9f2f-0eb9a6e71b18'), 'workflowProcessList' (ID: '00bfea71-2d77-4a75-9fca-76516689e21a'), 'WorkflowHistoryList' (ID: '00bfea71-4ea5-48d4-a4ad-305cf7030140'), 'XmlFormLibrary' (ID: '00bfea71-1e1d-4562-b56a-f05371bb0115'), 'TeamCollab' (ID: '00bfea71-4ea5-48d4-a4ad-7ea5c011abe5'), . 05/21/2010 12:22:57.15 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 8l1f Medium Feature Activation: Batch Activated Features at URL http://mmm-dev-ll/sites/Shoes/test 'AnnouncementsList' (ID: '00bfea71-d1ce-42de-9c63-a44004ce0104'), 'ContactsList' (ID: '00bfea71-7e6d-4186-9ba8-c047ac750105'), 'CustomList' (ID: '00bfea71-de22-43b2-a848-c05709900100'), 'DataSourceLibrary' (ID: '00bfea71-f381-423d-b9d1-da7a54c50110'), 'DiscussionsList' (ID: '00bfea71-6a49-43fa-b535-d15c05500108'), 'DocumentLibrary' (ID: '00bfea71-e717-4e80-aa17-d0c71b360101'), 'EventsList' (ID: '00bfea71-ec85-4903-972d-ebe475780106'), 'GanttTasksList' (ID: '00bfea71-513d-4ca0-96c2-6a47775c0119'), 'GridList' (ID: '00bfea71-3a1d-41d3-a0ee-651d11570120'), 'IssuesList' (ID: '00bfea71-5932-4f9c-ad71-1557e5751100'), 'LinksList' (ID: '00bfea71-2062-426c-90bf-714c59600103'), 'NoCodeWorkflowLibrary' (ID: '00bfea... 05/21/2010 12:22:57.15* w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 8l1f Medium ...71-f600-43f6-a895-40c0de7b0117'), 'PictureLibrary' (ID: '00bfea71-52d4-45b3-b544-b1c71b620109'), 'SurveysList' (ID: '00bfea71-eb8a-40b1-80c7-506be7590102'), 'TasksList' (ID: '00bfea71-a83e-497e-9ba0-7a5c597d0107'), 'WebPageLibrary' (ID: '00bfea71-c796-4402-9f2f-0eb9a6e71b18'), 'workflowProcessList' (ID: '00bfea71-2d77-4a75-9fca-76516689e21a'), 'WorkflowHistoryList' (ID: '00bfea71-4ea5-48d4-a4ad-305cf7030140'), 'XmlFormLibrary' (ID: '00bfea71-1e1d-4562-b56a-f05371bb0115'), 'TeamCollab' (ID: '00bfea71-4ea5-48d4-a4ad-7ea5c011abe5'), . 05/21/2010 12:22:57.15 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 88jb Medium Feature Activation: Activating Feature 'RadEditorFeatureRichText' (ID: '747755cd-d060-4663-961c-9b0cc43724e9') at URL http://mmm-dev-ll/sites/Shoes/test. 05/21/2010 12:22:57.15 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 75fb Medium Calling 'FeatureActivated' method of SPFeatureReceiver for Feature 'RadEditorFeatureRichText' (ID: '747755cd-d060-4663-961c-9b0cc43724e9'). 05/21/2010 12:22:57.20 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 75f8 Medium Feature Activation: Feature 'RadEditorFeatureRichText' (ID: '747755cd-d060-4663-961c-9b0cc43724e9') was activated at URL http://mmm-dev-ll/sites/Shoes/test. 05/21/2010 12:22:57.51 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services Fields 88yv Medium Creating default lists 05/21/2010 12:22:57.51 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 72lp Medium Creating directory Lists 05/21/2010 12:22:57.51 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services Fields 88yz Medium Creating default modules at URL "http://mmm-dev-ll/sites/Shoes/test" 05/21/2010 12:22:57.51 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 8e27 Medium Ensuring module folder _catalogs/masterpage 05/21/2010 12:22:57.56 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 72ix Medium Not enough information to determine a list for module "Default". Assuming no list for this module. 05/21/2010 12:22:57.87 w3wp.exe (0x1E40) 0x18A4 Windows SharePoint Services General 72h8 Medium Successfully applied template "SubSite#1" to web at URL "http://mmm-dev-ll/sites/Shoes/test". 05/21/2010 12:22:59.48 w3wp.exe (0x1E40) 0x0980 Windows SharePoint Services General 8e2s Medium Unknown SPRequest error occurred. More information: 0x80070057 05/21/2010 12:23:07.06 OWSTIMER.EXE (0x0884) 0x106C Office Server Setup and Upgrade 8u3j High Registry key value {SearchThrottled} was not found under registry hive {Software\Microsoft\Office Server\12.0}. Assuming search sku is not throttled. 05/21/2010 12:23:07.08 OWSTIMER.EXE (0x0884) 0x106C Search Server Common MS Search Administration 90gf Medium SQL: dbo.proc_MSS_PropagationGetQueryServers 05/21/2010 12:23:07.09 OWSTIMER.EXE (0x0884) 0x106C Search Server Common MS Search Administration 8wni High Resuming default catalog with reason 'GPR_PROPAGATION' for application 'SharedServices1'... 05/21/2010 12:23:07.11 OWSTIMER.EXE (0x0884) 0x106C Search Server Common MS Search Administration 8wnj High Resuming anchor text catalog with reason GPR_PROPAGATION' for application 'SharedServices1'... 05/21/2010 12:23:07.14 OWSTIMER.EXE (0x0884) 0x106C Search Server Common MS Search Administration 8dvl Medium Search application '3c6751cc-37b0-470a-bfa2-bfd0b5635fe1': Provision start addresses in default content source. 05/21/2010 12:23:07.15 OWSTIMER.EXE (0x0884) 0x106C Search Server Common MS Search Administration 7hmh High exception in SearchUpgradeProvisioner Keyword Config System.InvalidOperationException: jobServerSearchServiceInstance is null at Microsoft.Office.Server.Search.Administration.SearchUpgradeProvisioner..ctor(SearchServiceInstance searchServiceInstance) at Microsoft.Office.Server.Search.Administration.OSSPrimaryGathererProject.ProvisionContentSources() 05/21/2010 12:23:29.19 OWSTIMER.EXE (0x0884) 0x0FFC SharePoint Portal Server Business Data 79bv High Initiating BDC Cache Invalidation Check in AppDomain 'DefaultDomain' 05/21/2010 12:23:29.19 OWSTIMER.EXE (0x0884) 0x0FFC SharePoint Portal Server Business Data 79bx High Completed BDC Cache Invalidation Check in AppDomain 'DefaultDomain' 05/21/2010 12:23:45.84 OWSTIMER.EXE (0x0884) 0x08A8 SharePoint Portal Server SSO 8inc Medium In SSOService::Synch(), sso database conn string: 05/21/2010 12:23:50.80 OWSTIMER.EXE (0x0884) 0x0F14 Excel Services Excel Services Administration 8tqi Medium ExcelServerSharedWebApplication.Synchronize: Starting synchronize for instance of Excel Services in SSP 'SharedServices1'. 05/21/2010 12:23:50.80 OWSTIMER.EXE (0x0884) 0x0F14 Excel Services Excel Services Administration 8tqj Medium ExcelServerSharedWebApplication.Synchronize: Successfully synchronized instance of Excel Services in SSP 'SharedServices1'. 05/21/2010 12:23:52.31 w3wp.exe (0x1E40) 0x0980 SharePoint Portal Server Runtime 8gp7 Medium Topology cache updated. (AppDomain: /LM/W3SVC/1963195510/Root-1-129188762904047141)

    Read the article

< Previous Page | 18 19 20 21 22 23 24 25 26 27 28 29  | Next Page >