  • Journaled filesystems and power failure

    - by Yoga
    I heard that even a journaled filesystems such as EXT3/EXT4 might corrupted during power failure, e.g. from wikipedia [1]: In the event of a system crash or power failure, such file systems are quicker to bring back online and less likely to become corrupted. Can anyone provide more detail by giving examples such that when corruption can occur corruption is avoided by journaled filesystems [1] http://en.wikipedia.org/wiki/Journaling_file_system

    Read the article

  • UPS power requirements for server

    - by captainentropy
    Greetings! So, I just placed an order for a new server. The company recommended that I get a 3000W UPS. (!) As best as I could I calculated the following wattage consumption based on benchmarked data or datasheets provided by the manufacturers of each component: number watts **total watts** MoBo 1 240 240 CPUs (E5540) 2 80 160 RAID cards (3ware) 2 18 36 RAM (6x4GB) 6 3 18 DVD drive 1 7 7 floppy 1 2 2 RE4 drives 8 7 56 WD20 drives 8 6 48 Intel X25 SSD 2 0.15 0.3 total = 567 So that is for the PSU requirements only. The PSUs in the machine are a 720W for the master node and 800W each for two subsystems. That's a total of 2320W that can be delivered by these PSUs. But that is 4X the amount being consumed, at most, by the components. I didn't count case fans or the eSATA card (3W maybe?) or what the PSUs themselves require but assuming I double or triple my calculations I'm not even remotely close to the 3000W UPS I was suggested to get. They run at least $1100. I could get a 2000W for about $750 or a 1500W for $450 and still be well over my estimated power need. I don't think I need a whole lot of run time in the case of a power outage, maybe 20 minutes max, enough time to shutdown if the power doesn't come on within 5-10 minutes. Any thoughts? Am I off on my calculations? Did I overlook something major? If so what are your suggestions for a UPS? Thanks!

    Read the article

  • How to turn off screen (DPMS) together with locking session in KDE?

    - by gertvdijk
    First of all, I'm aware a similar question for GNOME is asked here: "Switch off laptop backlight when locking screen". Objective I would like to turn off my screen on locking the session for power saving reasons. Actual problem Locking the screen on Kubuntu (KDE) inevitably triggers the screensaver as far as I can see. There's no screensaver option other than 'Blank screen' together with its background colour set to black that comes just close to my goal. It blanks the screen, but doesn't turn off the screen. Screen's backlight will still be on and not saving any power. Current workaround A workaround via a script + shortcut key is possible, however, it's just a workaround since it doesn't trigger on all ways to lock the session. Therefore, I think it should be possible to have it done more elegantly, for example by providing this option in KDE's configuration dialog of the screensaver. The workaround I am now using is the following. A script that locks the screen and turns off the screen: #!/bin/bash qdbus org.freedesktop.ScreenSaver /ScreenSaver Lock xset dpms force standby and let it run with a shortcut key via a custom menu entry. It works. Here's why I consider it to be a workaround rather than a solution. It doesn't work for other ways to trigger the locking of the session. My actual question(s) Do I need to touching/patching KDE's source? If not what are my options? If so, could someone point me to where I can get started? what do you think is the recommended place in the GUI for configuration? I'm using Kubuntu 12.04 and willing to upgrade to KDE 4.9 or waiting for the 12.10 release.

    Read the article

  • The battery indicator in Unity panel not showing up

    - by user61415
    I installed Ubuntu 12.04 with Wubi. Well after being completely dazzled with the amount of free content in the Software Centre, I decided to go deeper and start messing with settings. Well after changing the screen brightness the highest level I noticed that there wasn't an indicator for how much battery was left in my laptop. I looked up online on got 2 suggestions on how to fix: Right click on the Unity panel and add an indicator Set it to show in the power settings menu. Well I did both when I right click at the top menu nothing comes up and setting it to show does nothing either. Then I tried installing something in the Software Centre. I got something but when I activated it it said I had 0% power left even though I was charging and at %100 according the Light in the front of my laptop. So now I'm thinking that it doesn't even recognise my computer as a laptop which is weird because in the display settings it says my screen size is set to laptop. How can I install it? I don't know what version it is other then Ubuntu 12.04 and no matter what the icon does not appear with the

    Read the article

  • How to stop switchable graphics from switching to high-power GPU when charging the laptop?

    - by Saifallah
    I've an Acer laptop with Windows 7 64 bit and an ATI Radeon HD 6550M Graphics card. Whenever I connect the power to charge the battery it automatically switches to the high-power GPU (ATI) instead of the low-power (Intel) GPU. There's an option in the bios to stop such thing but it makes the GPU runs always on high-power and I can't switch to the low-power GPU. How can I prevent the switchable graphics from automatically using the high-power GPU when charging?

    Read the article

  • Cooling Server Closet - No A/C Is Possible

    - by JamesCo
    We're moving into a new office in an old building in London (that's England :) and are walling off a 2m x 1.3m area where the router & telephone equipment currently terminates to use as a server closet. The closet will contain: 2 24-port switches 1 router 1 VSDL modem 1 Dell desktop 1 4-bay NAS 1 HP micro-server 1 UPS Miscellaneous minor telephony boxes. There is no central A/C in the office and there never will be. We can install ducting to the outside quite easily - it's only a couple of metres to the windows, which face a courtyard. My question is whether installing an extractor fan with ducting to the window should be sufficient for cooling? Would an intake fan and intake duct (from the window, too) be required? We don't want to leave a gap in the closet door as that'll let noise out into the office. If we don't have to put a portable A/C unit into the closet, that'd be perfect. The office has about 12 people; London is temperate, average maximum in August is 31 Celsius, 25 Celsius is more typical. The same equipment runs fine in our current office (same building as new office, also no A/C) but it isn't in an enclosed space. I can see us putting say one Dell 2950 tower server into the closet, but no more than that. So, sustained power consumption in the closet would currently be about 800w (I'm guessing); possibly in the future 2kw. The closet will have a ceiling and no windows and be well-insulated. We don't care if the equipment runs hot, so long as it runs and we don't hear it.

    Read the article

  • F#: how to find Cartesian power

    - by Nike
    I have a problem with writing a Cartesian power function. I found many examples about calculating Cartesian Product, but no one about Cartesian power. For example, [1;2] raised to power 3 = [ [1;1;1] ; [1;1;2] ; [1;2;1] ; [1;2;2] ; [2;1;1] ; [2;1;2] ; [2;2;1]; [2;2;2] ] I use following code to calculate Cartesian Product: let Cprod U V = let mutable res = [] for u in U do for v in V do res <- res @ [[u;v]] res And trying to calculate Cartesian power. I use following code to calculate Cartesian Product: let Cpower U n = let mutable V = U for i=0 to n-1 do V <- Dprod U V V Visual Studio said: Error The resulting type would be infinite when unifying ''a' and ''a list'. I will thankful for any help and links.

    Read the article

  • Xubuntu: Screen idle-dims after lock+new login although not idling

    - by unhammer
    I set my screen to dim after 2 minutes idling on battery in XFCE power settings. If I lock and click new login, and log in as another user, the screen will dim after 2 minutes even though that second user is active. Is there some setting or workaround for this? It feels like a bug, but I have no idea what program or combination of programs would be responsible … (I don't know if this affects Unity users or not.)

    Read the article

  • How to configure an Ubuntu 12.04 virtual server and VMWare ESXi5 the way VMWare would be able to shut it down properly?

    - by Ivan
    I run an Ubuntu 12.04 server as a virtual machine on a VMWare ESXi 5 server. I've configured VMWare to shut the quest machines down the sane way (with an ACPI (if I understand it righ) shutdown signal so that guest OSes would do it). And this works with other VMs (running Windows 7 Professional and openSuSE) but doesn't work with the Ubuntu server - VMWare still offers just to power them off when I ask it to stop the guest. Any ideas how to fix this?

    Read the article

  • When is a Kernel update due for 11.10?

    - by Mysterio
    Thanks to Phoronix there seems to be a fix for the power regression/overheating bug in the Linux Kernel 3.0.1 bouncing around on the Internet. However this supposed fix which I read has been patched to the Kernel in a testing phase is not newbie-friendly (if you know what I mean). So I am guessing it will be included in the kernel update for 11.10. If it will please when is it due? Linked Question: Kernel patch that solves battery issues when for ubuntu ?

    Read the article

  • Using Y split cables to connect two servers to a single PDU receptacle

    - by sagi
    We have bought a few 30amp 208v PDUs that only have 9 receptacles. The servers we are connecting to those PDUs will not use the full 30amps (at 80%, or actually 40% since we use redundant power) so we need to find a way to connect more than 9 servers to the same 9 receptacles so we'll be not wasting capacity that we pay for. I thought about using a Y split cable like this one: http://www.cablesandkits.com/power-cord-c14-c13-splitter-cable-awg-p-515.html That will let me connect two servers to a single receptacle. Each of the individual receptacles can provide 12 amps of power and individual servers are unlikely to consume more than 3 amps at maximal load so it should provide sufficient power. The question is if there is any other reason why this may be a bad idea and if there is any other solution other than buying PDUs with more receptacles (which I don't want to do because I must use horizontal PDU on these racks and ones with more receptacles consume more U space).

    Read the article

  • Recommendation for a redundant 60V DC Powersupply

    - by Lairsdragon
    We have some Telco-Equipment in our data space center which we had been given by our Telco. What they didn't provide is a redundant power supply and therefore we are struggling with outages of this equipment. What I am searching for is a redundant Power-Supply for 60V and 600W 60 Volt DC output 600 Watts rated power 2 220V Input with galvanic separation Rack mountable Any suggestions?

    Read the article

  • Eject a USB modem in the scheduled tasks

    - by mantra
    Hi I need to schedule a task to eject a USB modem immediately when the power fail. I had searched in EventLog and found the EventID for power Failure, put it in the Triggers,but in the Action I didn't know how to put what will eject the modem. Can anybody please help me on this, I need it urgently, because my system crash on the power failure because of the USB modem. I have a UPS but I have no suitable power cable for the modem ( couldn't find one in my country ). I run win7 Ultimate

    Read the article

  • Motherboard on, but nothing will start

    - by Geeklat
    I'll try and be as clear as possible. Recently I purchased a barebones kit for my first attempt at a full PC assembly. I've gone through and connected all the parts correctly based on numerous examples that confirm everything is connected correctly. The motherboard and the video card are receiving power based on the fact that the motherboard's power LED is on and the video card has some LEDs on. Nothing else in the computer will come on when pressing the power button on the case. No fans, no hard drive, no CPU fan. Not even for a split second. I also receive no beeping noise from the speaker connected to the motherboard. I've also tried swapping the reset and power connectors from the front of the case to no luck.

    Read the article

  • SMPS stops when I plug in a SATA drive?

    - by claws
    Hello, Part 1: my first question is all the 4 wire power connectors (intended for hardisks/dvd drives not mother board) are same. Right? I've been using all of them same and I had no problem for years. Yesterday I borrowed a SATA disk from my friend and connected it my computer using Sata Power adaptor (4 wire) and when I switched on the computer. There were fumes coming out of the connector. I immediately turned it off (in just one second). I tested the voltages in the 4 wire power connector of my SMPS: They were 5.3v & 12.2V. I couldn't measure the current. But my SMPTS label reads: DC Output: 3.3v (25A) +5v (32A) -5v (0.3A) +12V (17A) -12V (0.8A) And the SATA hardisk label reads Input: +5v (0.72A) +12V (0.52A) I'm shocked! I never noticed this. Does the "sata power adaptor" scale down the current to required? If it doesn't, I've been connecting same way for years. I never had any problem. This is the first time I'm encountering it. Part 2: I wanted to return the drive to my friend. He has two hard disks, SATA & PATA. Its the SATA that I borrowed. When he usually switches on. The CPU fan starts & then stops for a sec and starts again and continues working. That was the earlier situation. I don't know why it stops & starts? Well, Now when I connect this SATA disk and switch ON the computer. CPU fan starts (just for an instant, not even a 0.5 sec) and stops. It doesn't start again, I mean the power from SMPS has stopped. But if I disconnect this SATA disk. It works fine. What seems to be the problem? I've no idea about why there were fumes or why his SMPS starts & stops giving power? What is its relation with the SATA disk connection?

    Read the article

  • Computer crashes and won't start, LED indicator blinks slowly

    - by hexacyanide
    I have a MSI K8NGM2-FID motherboard coupled with a AMD Athlon 3700+ and an Antec TPII-550 power supply. The computer crashes at random times in operation, sometimes taking a while to crash, and sometimes crashing right after Windows XP shows the desktop after boot. The CPU temperature is always in the safe range, usually 30-33 degrees Celsius, and swapping the RAM has not done anything, so the crashes aren't cause by the RAM. What could be causing this? If the motherboard were fried, would the computer even boot at all? What causes inconsistent crashing of the computer? After the computer crashes, the LED power indicator blinks about once a second, and the computer does not respond to the power button. This behavior continues until the computer's power supply is completely removed.

    Read the article

  • Run a pc on battery for 3 days?

    - by Zen 8000k
    I am looking for a low power, low end pc able to run 24/7 without overheating and a way to support it in case of power failure. Power failures can be up to 72 hours. The pc dosen't need a monitor or keyboard. A modem must also be protected in case of power failure. When i say low end, i don't mean crap. The cpu needs to be x86 and have at least 1k cpu in this chart: http://www.cpubenchmark.net/index.php What's the best way to do this?

    Read the article

  • Server only powers (but doesn't POST) when IDE drive is powered

    - by Jookia
    So after a thunderstorm last night which did a little damage, a Gigabyte server has decided it's going on power on but not POST. If it is POSTing, it's doing a very bad job at telling me. No beeps, nothing. Power seems to reach the components though. CD Drive opens and closes. So after stripping it back, I've found that the difference between this behaviour and deciding it's not going to power on for more than half a second, is having a power cable plugged in to one of the IDE hard drives. Is this normal, or a sign that the PSU has had it?

    Read the article

  • Wireless USB keyboard and mouse can wake system, but then receiver is inactive

    - by BlueMonkMN
    I have a Microsoft brand USB device that acts as a receiver for a wireless Microsoft Keyboard and a wireless Mouse. When it's operating normally, there are LEDs on the device indicating Caps Lock, Num Lock and Function Lock, of which the latter 2 are usually lit. It is plugged into a Dell Isnpiron 531 with Windows 7 32-bit running on an AMD Athlon 64 X2 Dual Core processor 5000+. When the computer goes to sleep (the power indicator on the main box is flashing), I can wake it by moving the mouse. So far all is good. However, something changed in, I think, the past couple weeks (I suspect due to a Microsoft driver update problem). Before the change, after waking the computer, everything would operate normally as far as I could tell, but now after waking the computer, the receiver has no lights on, and the keyboard and mouse are completely unresponsive (which is odd, considering the mouse woke up the computer). There is a button on the receiver that's supposed to reset the wireless connection and flash the lights while it does so, but it has no effect in this state. It's like the receiver doesn't have power (but how would the system know I moved the mouse, unless the power was on until it woke up?). I have checked the BIOS/CMOS settings or whatever you call them, and did not see anything related to USB in the power management section. I have checked Windows 7 device manager and ensured that all the USB Root Hub devices have the setting unchecked for allowing the USB power to be turned off. Like I said, this was working before, and the only thing I can think of that's changed is applying Windows Updates.

    Read the article

  • would unexpected power cuts harm the Linux OS?

    - by Johan Elmander
    I am developing an application on a Linux embedded board (runs Debian) e.g. Raspberry Pi, Beagle Board/Bone, or olimex. The boards works on an environment that the electricity is cut unexpectedly (it is far complicated to place PSU, etc.) and it would happen every day couple times. I wonder if the unexpected power cuts would cause crash/problem on the Linux Operation System? If it is something that I should worry, what would you suggest to prevent the damages on OS against the unexpected power cuts? PS. The application needs to writes some data to the storage medium (SD card), I think it would not be suitable to mount it as read-only.

    Read the article