  • Oracle OpenWorld Call for MDM Papers

    - by david.butler(at)oracle.com
    As the MDM Track owner, I would like to invite everyone to respond to the Oracle OpenWorld (October 2-6, Moscone Center, San Francisco) Call for Papers (https://oracleus.wingateweb.com/portal/cfp/ ). The Call for Papers is open now through Sunday, March 27. This is an outstanding opportunity for organizations familiar with MDM to tell their story to a very large, knowledgeable and intensely interested community. Opportunities for feedback and networking abound.  I would love to see MDM papers on: business drivers; business benefits; quantified ROI stories; business process optimization; implementation styles; implementation lessons learned; using master data as a service; data governance best practices; end-to-end data quality experiences; support for SOA; Chart of Accounts issues fixed; how to leverage reference data; improving EPM and/or BI across the board; operationalizing a data warehouse; support for cloud computing; compliance success stories; architecture, scalability, and mixed workload RAC platform performance examples; industry specific value propositions (Financial Services; Retail, Telecom; Manufacturing, High Tech Manufacturing, Public Sector, Health Care, …); and line of business specific value propositions (CRM, ERP, PLM, SCM, …); etc. In fact, given that MDM positively impacts all areas of operations and analytics, there are no limits to the ideas you may have for an OpenWorld presentation. When you follow the submission process, be sure to use “Master Data Management” for either the Primary or Optional track. Add “Master Data Management” as an Optional track if you are adding MDM content to a presentation on one of the following tracks: Agile; Customer Relationship Management, Oracle E-Business Suite, Product Lifecycle Management, Siebel, Sourcing and Procurement, Supply Chain Management, or one of the 18 available industry tracks. If Cloud Computing is included, please add “Cloud Computing” as a Cross-Stream Track. And don’t forget to make “MDM” a Tag, along with Business Intelligence, Cloud, CRM, Data Integration, Data Migration, Data Warehousing, EPM, or Service-Oriented Architecture whenever your content includes these items. I will personally review each submission. I hope you all keep me very busy over the next few weeks.

    Read the article

  • ArchBeat Link-o-Rama for 2012-08-29

    - by Bob Rhubart
    ORCLville: OOW 2012 - Crystal BallOracle ACE Director Floyd Teter cooks up some tongue-in-cheek predictions for news and announcements that might come out of Oracle OpenWorld 2012. What's your prediction? Oracle Optimized Solutions at Oracle OpenWorld 2012 | Oracle Hardware Hardware matters, too! The people behind the Oracle Hardware blog have put together a list of Oracle Openworld 2012 sessions focused Oracle Optimized Solutions, "designed, pre-tested, tuned and fully documented architectures for optimal performance and availability." Just plug the session ID numbers into Schedule Builder and you're good to go. AIX Checklist for stable OBIEE deployment | Dick Dunbar "OBIEE is a complicated system with many moving parts and connection points," according to Oracle Business Inteligence escalation engineer Dick Dunbar. "The purpose of this article is to provide a checklist to discuss OBIEE deployment with your systems administrators." Demo for OPN: Coherence Management with EM Cloud Control 12c Oracle Partner Network members can check out a new Coherence Management demo that showcases some of the key capabilities of Management Pack for Oracle Coherence and JVM Diagnostics. "The demo flow showcases the key enhancements made in Enterprise Manager 12c release which includes new customizable performance summary, cache data management and configuration management," according to the WebLogic Partner Community EMEA blog. The Pragmatic Architect: To Boldly Go Where No One Has Gone Before | Frank Buschmann "Many architects have technical knowledge that's both impressive and sound, which is indeed an inevitable basis for design success," says Frank Buschmann. "Yet, a lot of software projects fail or suffer due to severe challenges in their architecture. The key to mastery is how architects approach design, what they value, and where they focus their attention and work." As retail dies, whom will be the winners? | Peter Evans-Greenwood "The problem for many retailers is that how consumers shop has changed but the the retailers haven't adapted, " says Peter Evans-Greenwood. "Their sole virtue was to be the last step in a supply chain delivering somebody else's products to the consumer. However, being the last step in the supply chain is no longer a virtue when consumers skip across channels and can reach around the globe, no longer dependant on or limited to what they can find locally." Thought for the Day "Brains require stimulation. If you're locked into a pattern of work, work, and more work, your brain soon habituates - the same way that it lets you stop hearing a clock ticking. So, if you want to be more effective at work, you must, paradoxically, be less single-minded in your devotion to work. Anything you do—anything—that stimulates new segments of your brain will make you a more effective programmer or analyst. I promise, with a money-back guarantee." — Gerald M. Weinberg Source: SoftwareQuotes.com

    Read the article

  • Cannot Mount USB 3.0 Hard Disk ?!!

    - by Tenken
    Hi, I have a USB 3.0 external hard disk which I am unable to mount. The entry appears in the "lsusb" command, but I do not exactly understand how to mount it. This is the output for my lsusb command. "ASMedia Technology Inc." is the USB 3.0 device. I would appreciate some help in mounting and accessing the hard disk. This the relevant output of my "lsusb -v" : Bus 009 Device 002: ID 174c:5106 ASMedia Technology Inc. Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x174c ASMedia Technology Inc. idProduct 0x5106 bcdDevice 0.01 iManufacturer 2 ASMedia iProduct 3 AS2105 iSerial 1 00000000000000000000 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 009 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 3.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 3 bMaxPacketSize0 9 idVendor 0x1d6b Linux Foundation idProduct 0x0003 3.0 root hub bcdDevice 2.06 iManufacturer 3 Linux 2.6.35-28-generic xhci_hcd iProduct 2 xHCI Host Controller iSerial 1 0000:04:00.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x0009 Per-port power switching Per-port overcurrent protection TT think time 8 FS bits bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0503 highspeed power enable connect Port 4: 0000.0503 highspeed power enable connect Device Status: 0x0003 Self Powered Remote Wakeup Enabled This is the error given when I try to mount the hard drive: shinso@shinso-IdeaPad:~$ sudo mount /dev/sdb /mnt [sudo] password for shinso: mount: /dev/sdb: unknown device This the output of "dmesg|tail": [30062.774178] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [30535.800977] usb 9-4: USB disconnect, address 3 [30659.237342] Valid eCryptfs headers not found in file header region or xattr region [30659.237351] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [31259.268310] Valid eCryptfs headers not found in file header region or xattr region [31259.268313] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [31860.059058] Valid eCryptfs headers not found in file header region or xattr region [31860.059062] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [32465.220590] Valid eCryptfs headers not found in file header region or xattr region [32465.220593] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO I am using Ubuntu 10.10 (64 bit). Any help is appreciated.

    Read the article

  • WebCenter Customer Spotlight: Indecopi

    - by me
    Author: Peter Reiser - Social Business Evangelist, Oracle WebCenter  Solution SummaryIndecopi Optimizes Patent Approval Management and Accelerates Customer Service Times by 40% Indecopi is a decentralized public agency that promotes the country’s markets and protects consumer rights. It promotes fair and honest competition and safeguards all forms of intellectual property through three directorates: Author’s Rights, Inventions and New Technologies, and Trademarks. The business challenge was to unify the agency’s technology infrastructure to create a business process management strategy, consolidate the organization’s Web platform and improve and automate information services for citizens and businesses, and streamline patent procedures by digitizing documentation. Indecopi optimized patent information services , organized information, provided around-the-clock online access to users, and developed a Web site that provides internal and external users access to DIN information, such as patent documentation, through a user-friendly interface. Indecopi achieved impressive business result by reducing use of paper files by 50%, accelerating transaction approvals,  reduce nonvalue-added activities by 85% and  accelerated customer service times by 40%. Company OverviewPeru’s Instituto Nacional de Defensa de la Competencia y de la Protección de la Propiedad Intelectual (Indecopi), the National Institute for the Defense of Competition and Protection of Intellectual Property, is a decentralized public agency that promotes the country’s markets and protects consumer rights. It promotes fair and honest competition and safeguards all forms of intellectual property through three directorates: Author’s Rights, Inventions and New Technologies, and Trademarks. Business ChallengesIndecopi's challenge was to unify the agency’s technology infrastructure to create a business process management strategy, starting with the Directorate of Inventions and New Technologies (DIN), consolidate the organization’s Web platform to meet new demands for software and process development, such as for patent applications, and improve and automate information services for citizens and businesses and streamline patent procedures by digitizing documentation. Solution DeployedIndecopi optimized patent information services with Oracle Business Process Management, automating processes to deliver expedient searches, and to create new services, such as alerts to users. They organized information and provided around-the-clock online access to users with Oracle WebCenter Content. In addition they used Oracle WebLogic Server to develop a Web site that provides internal and external users access to DIN information, such as patent documentation, through a user-friendly interface. Business Results Indecopi achieved impressive business results Reduced use of paper files by 50% Accelerated transaction approvals  reduce nonvalue-added activities, such as manual document copying to obtain patents, by 85% Accelerated customer service times by 40% by optimizing procedures, such as searches and online information related to granting patents “Oracle Business Process Manager has been a paradigm shift in process management. By digitalizing and automating our patents information services, we can now manage everything in the simplest way possible, expanding our options for the creation of new services.” Sergio Rodríguez, Assistant Director, Inventions and New Technologies Directorate, Instituto Nacional de Defensa de la Competencia y la Propiedad Intelectual Additional Information Indecopi Customer Snapshot Oracle WebCenter Content

    Read the article

  • The Best Data Integration for Exadata Comes from Oracle

    - by maria costanzo
    Oracle Data Integrator and Oracle GoldenGate offer unique and optimized data integration solutions for Oracle Exadata. For example, customers that choose to feed their data warehouse or reporting database with near real-time throughout the day, can do so without decreasing  performance or availability of source and target systems. And if you ask why real-time, the short answer is: in today’s fast-paced, always-on world, business decisions need to use more relevant, timely data to be able to act fast and seize opportunities. A longer response to "why real-time" question can be found in a related blog post. If we look at the solution architecture, as shown on the diagram below,  Oracle Data Integrator and Oracle GoldenGate are both uniquely designed to take full advantage of the power of the database and to eliminate unnecessary middle-tier components. Oracle Data Integrator (ODI) is the best bulk data loading solution for Exadata. ODI is the only ETL platform that can leverage the full power of Exadata, integrate directly on the Exadata machine without any additional hardware, and by far provides the simplest setup and fastest overall performance on an Exadata system. We regularly see customers achieving a 5-10 times boost when they move their ETL to ODI on Exadata. For  some companies the performance gain is even much higher. For example a large insurance company did a proof of concept comparing ODI vs a traditional ETL tool (one of the market leaders) on Exadata. The same process that was taking 5hrs and 11 minutes to complete using the competing ETL product took 7 minutes and 20 seconds with ODI. Oracle Data Integrator was 42 times faster than the conventional ETL when running on Exadata.This shows that Oracle's own data integration offering helps you to gain the most out of your Exadata investment with a truly optimized solution. GoldenGate is the best solution for streaming data from heterogeneous sources into Exadata in real time. Oracle GoldenGate can also be used together with Data Integrator for hybrid use cases that also demand non-invasive capture, high-speed real time replication. Oracle GoldenGate enables real-time data feeds from heterogeneous sources non-invasively, and delivers to the staging area on the target Exadata system. ODI runs directly on Exadata to use the database engine power to perform in-database transformations. Enterprise Data Quality is integrated with Oracle Data integrator and enables ODI to load trusted data into the data warehouse tables. Only Oracle can offer all these technical benefits wrapped into a single intelligence data warehouse solution that runs on Exadata. Compared to traditional ETL with add-on CDC this solution offers: §  Non-invasive data capture from heterogeneous sources and avoids any performance impact on source §  No mid-tier; set based transformations use database power §  Mini-batches throughout the day –or- bulk processing nightly which means maximum availability for the DW §  Integrated solution with Enterprise Data Quality enables leveraging trusted data in the data warehouse In addition to Starwood Hotels and Resorts, Morrison Supermarkets, United Kingdom’s fourth-largest food retailer, has seen the power of this solution for their new BI platform and shared their story with us. Morrisons needed to analyze data across a large number of manufacturing, warehousing, retail, and financial applications with the goal to achieve single view into operations for improved customer service. The retailer deployed Oracle GoldenGate and Oracle Data Integrator to bring new data into Oracle Exadata in near real-time and replicate the data into reporting structures within the data warehouse—extending visibility into operations. Using Oracle's data integration offering for Exadata, Morrisons produced financial reports in seconds, rather than minutes, and improved staff productivity and agility. You can read more about Morrison’s success story here and hear from Starwood here. From an Irem Radzik article.

    Read the article

  • Oracle Partner Architects Training

    - by mseika
    Dear Oracle Partner, There is a lot more to Oracle technology than meets the eye. Sure, you already belong to a small circle of our most experienced and committed partners. But are you making the best use possible of our technology solutions? Put it to the test.  Join the “Oracle Partner Architects Training”. It is aimed at providing your experts, architects and consultants with in-depth architectural knowledge about Oracle technology. Here is your chance to learn from the best. Seasoned speakers, exclusive content and no product marketing. Oracle technology beyond the obvious. Choose from any of the 40 recorded training sessions. Topics include:  • Security• Service integration • Database and options• Data integration • BI and applications• Applications and infrastructure• Hardware and software combinations The market and Oracle value specialized partners More information about specialization can be found on opn.oracle.com. Click through to OPN Program/Specialize “What’s in it for us?” Quite simply: the opportunity to gain the differentiation and competitive edge you need to stand out in the marketplace. • Differentiate your company through expertise in leading Oracle IT solutions;• Get your experts, architects and consultants up to speed on specialized services and solutions;• Make our customers’ shortlists. They are looking for value-added solutions for their business.   Recordings All sessions are recorded. After registering for a session in oraevents, you will receive the info to access the webex recording. Your timing, your tempo.  Registration and more information Visit architects.oraevents.eu to sign up for the recorded sessions. NOTE: Looking to get your consultants Oracle certified? One more reason to join the Oracle Partner Architects Training. It is the fast track to getting their expertise validated with an Oracle certificate. Training schedule  Choose from any of the 40 recorded training sessions: SECURITY THE PRACTICAL APPROACH •  Identity governance• Access management• Data privacy and protection• End-to-end security, layers of exposures•  Identity & access management, why and where to start?• Data security, how? SERVICE INTEGRATION A NEW ROADTO ENTERPRISE-WIDE SERVICE INTEGRATION • Oracle RUEI: maximize business value by insight into real end-user experiences•  Governance challenges in the services landscape•  Creating an agile enterprise (by Jeff Davies)• Oracle’s approach to SOA (by Jeff Davies) - guiding and accelerating SOA success• Technical case study – the SOA challenge• Oracle’s unified business process management suite 11g (incl. demo) DATABASE DATABASE AND OPTIONS, GOINGWIDE •  Understanding service level agreements for databases• Database lifecycle management• Data centric information lifecycle management DATA INTEGRATION  DIS FOR ARCHITECTS • Data integration solutions: an overview• ODI and goldengate• Data quality

    Read the article

  • AI to move custom-shaped spaceships (shape affecting movement behaviour)

    - by kaoD
    I'm designing a networked turn based 3D-6DOF space fleet combat strategy game which relies heavily on ship customization. Let me explain the game a bit, since you need to know a bit about it to set the question. What I aim for is the ability to create your own fleet of ships with custom shapes and attached modules (propellers, tractor beams...) which would give advantages and disadvantages to each ship, so you have lots of different fleet distributions. E.g., long ship with two propellers at the side would let the ship spin around that plane easily, bigger ships would move slowly unless you place lots of propellers at the back (therefore spending more "construction" points and energy when moving, and it will only move fast towards that direction.) I plan to balance all the game around this feature. The game would revolve around two phases: orders and combat phase. During the orders phase, you command the different ships. When all players finish the order phase, the combat phase begins and the ship orders get resolved in real-time for some time, then the action pauses and there's a new orders phase. The problem comes when I think about player input. To move a ship, you need to turn on or off different propellers if you want to steer, travel forward, brake, rotate in place... These propellers don't have to work at their whole power, so you can achieve more movement combinations with less propellers. I think this approach is a bit boring. The player doesn't want to fiddle with motors or anything, you just want to MOVE and KILL. The way I intend the player to give orders to these ships is by a destination and a rotation, and then the AI would calculate the correct propeller power to achive that movement and rotation. Propulsion doesn't have to be the same throught the entire turn calculation (after the orders have been given) so it would be cool if the ships reacted as they move, adjusting the power of the propellers for their needs dynamically, but it may be too hard to implement and it's not really needed for the game to work. In both cases, how would that AI decide which propellers to activate for the best (or at least not worst) trajectory to be achieved? I though about some approaches: Learning AI: The ship types would learn about their movement by trial and error, adjusting their behaviour with more uses, and finally becoming "smart". I don't want to get involved THAT far in AI coding, and I think it can be frustrating for the player (even if you can let it learn without playing.) Pre-calculated timestep movement: Upon ship creation, ALL possible movements are calculated for each propeller configuration and power for a given delta-time. Memory intensive, ugly, bad. Pre-calculated trajectories: The same as above but not for each delta-time but the whole trajectory, which would then be fitted as much as possible. Requires a fixed propeller configuration for the whole combat phase and is still memory intensive, ugly and bad. Continuous brute forcing: The AI continously checks ALL possible propeller configurations throughout the entire combat phase, precalculates a few time steps and decides which is the best one based on that. Con: what's good now might not be that good later, and it's too CPU intensive, ugly, and bad too. Single brute forcing: Same as above, but only brute forcing at the beginning of the simulation, so it needs constant propeller configuration throughout the entire combat phase. Coninuous angle check: This is not a full movement method, but maybe a way to discard "stupid" propeller configurations. Given the current propeller's normal vector and the final one, you can approximate the power needed for the propeller based on the angle. You must do this continuously throughout the whole combat phase. I figured this one out recently so I didn't put in too much thought. A priori, it has the "what's good now might not be that good later" drawback too, and it doesn't care about the other propellers which may act together to make a better propelling configuration. I'm really stuck here. Any ideas?

    Read the article

  • WebCenter Customer Spotlight: Regency Centers Corporation

    - by me
    Author: Peter Reiser - Social Business Evangelist, Oracle WebCenter  Solution SummaryRegency Centers Corporation, based in Jacksonville, FL, is a leading national owner, operator, and developer of grocery-anchored and community shopping centers. Regency grew rapidly over much of the last decade. To keep up with the monthly and yearly administrative processes required to manage thousands of tenants, including reconciling yearly pass-through expenses, the customer upgraded to Oracle’s JD Edwards EnterpriseOne Version 9.0 and deployed Oracle WebCenter Imaging, Process Management and Oracle BI Publisher, to streamline invoice processing and reporting. Using Oracle WebCenter Imaging - Regency accelerated and improved vendor invoice accuracy  which increases process integrity by identifying potential duplicate bills while enabling rapid approval of electronic invoice documents. Company Overview Regency Centers Corporation, based in Jacksonville, FL,  is a leading national owner, operator, and developer of grocery-anchored and community shopping centers. The company owns 367 centers, totaling nearly 50 million square feet, located in top markets throughout the United States. Founded in 1963 and operating as a fully integrated real estate company, Regency is a qualified real estate investment trust that is self-administered and self-managed, operating from 17 regional offices around the country.  Business Challenges Ensure continued support of vital business applications that drive the real estate developer’s key business processes, including property management and tenant payment processing Streamline year-end expense recognition and calculation, enabling faster tenant billing Move to a Web-based platform to deliver greater mobility and convenience to employees Minimize system customizations to reduce IT management costs and burden moving forward Solution DeployedRecency Centers Corporation worked with the  Oracle Partner ICS to upgrade to Oracle’s JD Edwards EnterpriseOne Version 9.0, migrating to a more user-friendly, Web-based platform and realizing numerous new efficiencies in property management and tenant payment processing. They accelerated and improved vendor invoice accuracy with Oracle WebCenter Imaging, which increases process integrity by identifying potential duplicate bills while enabling rapid approval of electronic invoice documents. Business Results Enabled faster and more accurate tenant billing for year-end expenses, accelerating collections of millions of dollars in revenue Gained full audit and drill-down capabilities that facilitate understanding various aspects of calculations for expense participation generation Increases process integrity by identifying potential duplicate bills while enabling rapid approval of electronic invoice documents Helped to ensure on-time payments to hundreds of vendors, including contractors and utilities "We have realized numerous efficiencies with Oracle’s JD Edwards EnterpriseOne 9.0, particularly around tenant billings. It accelerates our year-end expense reconciliation process and enables us to create and process billings more quickly.” James Chiang, Vice President of Real Estate Accounting Regency Centers Corporation Additional Information Regency Centers Corporation Customer Snapshot Oracle WebCenter Imaging JD Edwards EnterpriseOne Financials 9.0 JD Edwards EnterpriseOne Project Costing JD Edwards EnterpiseOne Real Estate Management Oracle Business Intelligence Publisher Oracle Essbase

    Read the article

  • Monitoring C++ applications

    - by Scott A
    We're implementing a new centralized monitoring solution (Zenoss). Incorporating servers, networking, and Java programs is straightforward with SNMP and JMX. The question, however, is what are the best practices for monitoring and managing custom C++ applications in large, heterogenous (Solaris x86, RHEL Linux, Windows) environments? Possibilities I see are: Net SNMP Advantages single, central daemon on each server well-known standard easy integration into monitoring solutions we run Net SNMP daemons on our servers already Disadvantages: complex implementation (MIBs, Net SNMP library) new technology to introduce for the C++ developers rsyslog Advantages single, central daemon on each server well-known standard unknown integration into monitoring solutions (I know they can do alerts based on text, but how well would it work for sending telemetry like memory usage, queue depths, thread capacity, etc) simple implementation Disadvantages: possible integration issues somewhat new technology for C++ developers possible porting issues if we switch monitoring vendors probably involves coming up with an ad-hoc communication protocol (or using RFC5424 structured data; I don't know if Zenoss supports that without custom Zenpack coding) Embedded JMX (embed a JVM and use JNI) Advantages consistent management interface for both Java and C++ well-known standard easy integration into monitoring solutions somewhat simple implementation (we already do this today for other purposes) Disadvantages: complexity (JNI, thunking layer between native C++ and Java, basically writing the management code twice) possible stability problems requires a JVM in each process, using considerably more memory JMX is new technology for C++ developers each process has it's own JMX port (we run a lot of processes on each machine) Local JMX daemon, processes connect to it Advantages single, central daemon on each server consistent management interface for both Java and C++ well-known standard easy integration into monitoring solutions Disadvantages: complexity (basically writing the management code twice) need to find or write such a daemon need a protocol between the JMX daemon and the C++ process JMX is new technology for C++ developers CodeMesh JunC++ion Advantages consistent management interface for both Java and C++ well-known standard easy integration into monitoring solutions single, central daemon on each server when run in shared JVM mode somewhat simple implementation (requires code generation) Disadvantages: complexity (code generation, requires a GUI and several rounds of tweaking to produce the proxied code) possible JNI stability problems requires a JVM in each process, using considerably more memory (in embedded mode) Does not support Solaris x86 (deal breaker) Even if it did support Solaris x86, there are possible compiler compatibility issues (we use an odd combination of STLPort and Forte on Solaris each process has it's own JMX port when run in embedded mode (we run a lot of processes on each machine) possibly precludes a shared JMX server for non-C++ processes (?) Is there some reasonably standardized, simple solution I'm missing? Given no other reasonable solutions, which of these solutions is typically used for custom C++ programs? My gut feel is that Net SNMP is how people do this, but I'd like other's input and experience before I make a decision.

    Read the article

  • Partners - Steer Clear of the Unknown with Oracle Enterprise Manager12c and Plug-in Extensibility

    - by Get_Specialized!
    Imagine if you just purchased a new car and as you entered the vehicle to drive it home and you found there was no steering wheel. And upon asking the dealer you were told that it was an option and you had a choice now or later of a variety of aftermarket steering wheels that fit a wide variety of automobiles. If you expected the car to already have a steering wheel designed to manage your transportation solution, you might wonder why someone would offer an application solution where its management is not offered as an option or come as part of the solution... Using management designed to support the underlying technology and that can provide management and support  for your own Oracle technology based solution can benefit your business  a variety of ways: increased customer satisfaction, reduction of support calls, margin and revenue growth. Sometimes when something is not included or recommended , customers take their own path which may not be optimal when using your solution and has later impact on the customers satisfaction or worse a negative impact on their business. As an Oracle Partner, you can reduce your research, certification, and time to market by selecting and offering management designed, developed, and supported for Oracle product technology by Oracle with Oracle Enterprise Manager 12c. For partners with solution specific management needs or seeking to differentiate themselves in the market, Enterprise Manager 12c is extensible and provides partners the opportunity to create their own plug-ins as well as a validation program for them.  Today a number of examples by partners are available and Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-family:"Calibri","sans-serif"; mso-ascii- mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi- mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} more on the way from such partners as NetApp for NetApp storage and Blue Medora for VMware vSphere. To review and consider further for applicability to your solution, visit  the Oracle PartnerNetwork KnowledgeZone for Enterprise Manager under the Develop Tab http://www.oracle.com/partners/goto/enterprisemanager

    Read the article

  • WebCenter Customer Spotlight: Alberta Agriculture and Rural Developmen

    - by me
    Author: Peter Reiser - Social Business Evangelist, Oracle WebCenter  Solution SummaryAlberta Agriculture and Rural Development is a government ministry that works with producers and consumers to create a strong, competitive, and sustainable agriculture and food industry in the province of Alberta, Canada The primary business challenge faced by the Alberta Ministry of Agriculture was that of managing the rapid growth of their information.  They needed to incorporate a system that would work across 22 different divisions within the ministry and deliver an improved and more efficient experience for Desktop, Web and Mobile users, while addressing their regulatory compliance needs as part of the Canadian government. The customer implemented a centralized Enterprise Content Management solution based on Oracle WebCenter Content and developed a strong and repeatable information life cycle management methodology across all their 22 divisions and agencies. With the implemented solution, Alberta Agriculture and Rural Development  centrally manages over 20 million documents for 22 divisions and agencies and they have improved time required to find records,  reliability of information, improved speed and accuracy of reporting and data security. Company OverviewAlberta Agriculture and Rural Development is a government ministry that works with producers and consumers to create a strong, competitive, and sustainable agriculture and food industry in the province of Alberta, Canada.  Business ChallengesThe business users were overwhelmed by growth in documents (over 20 million files across 22 divisions and agencies) and it was difficult to find and manage documents and versions. There was a strong need for a personalized easy-to-use, secure and dependable method of managing and consuming content via desktop, Web, and mobile, while improving efficiency and maintaining regulatory compliance by removing the risk of non-uniform approaches to retention and disposition. Solution DeployedAs a first step Alberta Agriculture and Rural Development developed a business case with clear defined business drivers: Reduce time required to find records Locate “lost” records Capture knowledge lost through attrition Increase the ease of retrieval Reduce personal copies Increase reliability of information Improve speed and accuracy of reporting Improve data security The customer implemented a centralized Enterprise Content Management solution based on Oracle WebCenter Content. They used an incremental implementation approach aligned with their divisional and agency structure which allowed continuous process improvement. This led to a very strong and repeatable information life cycle management methodology across all their 22 divisions and agencies. Business ResultsAlberta Agriculture and Rural Development achieved impressive business results: Centrally managing over 20 million files for 22 divisions and agencies Federated model to manage documents in SharePoint and other applications Doing records management for both paper and electronic records Reduced time required to find records Increased the ease of retrieval Increased reliability of information Improved speed and accuracy of reporting Improved data security Additional Information Oracle Open World 2012 Presentation Oracle WebCenter Content

    Read the article

  • Failing Sata HDD

    - by DaveCol
    I think my HDD is fried... Could someone confirm or help me restore it? I was using Hardware RAID 1 Configuration [2 x 160GB SATA HDD] on a CentOS 4 Installation. All of a sudden I started seeing bad sectors on the second HDD which stopped being mirrored. I have removed the RAID array and have tested with SMART which showed the following error: 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 I have no clue what this means, or if I can recover from it. Could someone give me some ideas on how to fix this, or what HDD to get to replace this? Complete SMART report: Smartctl version 5.33 [i686-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: GB0160CAABV Serial Number: 6RX58NAA Firmware Version: HPG1 User Capacity: 160,041,885,696 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a Local Time is: Tue Oct 19 13:42:42 2010 COT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 433) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 54) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0 3 Spin_Up_Time 0x0002 097 097 000 Old_age Always - 0 4 Start_Stop_Count 0x0033 100 100 020 Pre-fail Always - 152 5 Reallocated_Sector_Ct 0x0033 095 095 036 Pre-fail Always - 214 7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 73109713 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15133 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0033 100 100 020 Pre-fail Always - 154 184 Unknown_Attribute 0x0032 038 038 000 Old_age Always - 62 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 189 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0 190 Unknown_Attribute 0x001a 061 055 000 Old_age Always - 656408615 194 Temperature_Celsius 0x0000 039 045 000 Old_age Offline - 39 (Lifetime Min/Max 0/22) 195 Hardware_ECC_Recovered 0x0032 070 059 000 Old_age Always - 12605265 197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 1 198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 62 SMART Error Log Version: 1 ATA Error Count: 4645 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 4645 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 02 7b 86 b1 ea 00 00:38:52.796 READ DMA ec 03 45 00 00 00 a0 00 00:38:52.796 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:52.794 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 04 79 86 b1 ea 00 00:38:49.935 READ DMA Error 4644 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 04 79 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:49.935 READ DMA Error 4643 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4642 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4641 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15131 - # 2 Short offline Completed without error 00% 15131 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • Hard Disk DRDY error: is it a crash

    - by pranjal
    I am using IBM Thinkpad, 1.7GHz, 512 RAM with Linux Mint 9 installed. I have two partitions in addition to root. One of the partitions became read-only yesterday, after which I rebooted my system. It is extremely slow along with DRDY Error : Is my Hard disk crashed ? Error Log while booting. Differences between boot sector and its backup. failed command : READ DMA BMDMA : stat 0X25 ata 1.00 : status : { DRDY ERR } ata 1.00 : status :{ UNC } Buffer I/O error on logical device, logical block 65467 smartctl output for the partition: mint mint # smartctl -a /dev/sda1 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: TOSHIBA MK4026GAX RoHS Serial Number: X5LY1623T Firmware Version: PA107E User Capacity: 40,007,761,920 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 6 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Thu Feb 17 06:48:25 2011 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 153) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 310 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 3968 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 40 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 7257 10 Spin_Retry_Count 0x0033 179 100 030 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3484 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 489 193 Load_Cycle_Count 0x0032 064 064 000 Old_age Always - 367150 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 36 (Lifetime Min/Max 14/57) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 33 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 82 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 1 199 UDMA_CRC_Error_Count 0x0032 200 253 000 Old_age Always - 0 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 101 222 Loaded_Hours 0x0032 085 085 000 Old_age Always - 6146 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 227 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0 SMART Error Log Version: 1 ATA Error Count: 2371 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2371 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:10.061 READ DMA f8 00 00 00 00 00 e0 00 00:03:10.061 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:10.053 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:10.053 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:10.053 READ NATIVE MAX ADDRESS Error 2370 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:03.328 READ DMA f8 00 00 00 00 00 e0 00 00:03:03.327 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:03.320 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:03.319 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:03.319 READ NATIVE MAX ADDRESS Error 2369 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:56.582 READ DMA f8 00 00 00 00 00 e0 00 00:02:56.582 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:56.574 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:56.574 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:56.574 READ NATIVE MAX ADDRESS Error 2368 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:49.809 READ DMA f8 00 00 00 00 00 e0 00 00:02:49.809 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:49.801 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:49.801 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:49.801 READ NATIVE MAX ADDRESS Error 2367 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:43.056 READ DMA f8 00 00 00 00 00 e0 00 00:02:43.056 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:43.048 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:43.048 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:43.047 READ NATIVE MAX ADDRESS SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging Do I need to get a new Hard Disk my PC ?

    Read the article

  • Why are my USB 2.0 devices hanging Windows XP?

    - by BenAlabaster
    Background on the machine I'm having a problem with: The machine was inherited and appears to be circa 2003 (there's a date stamp on the power supply which leads me to this conclusion). I've got it set up as a Skype terminal for my 2 year old to keep in touch with her grandparents and other members of the family - which everyone loves. It has a DFI CM33-TL/G ATX (identified using SiSoft Sandra) motherboard hosting an Intel Celeron 1.3GHz CPU, 768Mb PC133 SDRAM, a D-LINK WDA-2320 54G Wi-Fi network card and a generic USB 2.0 expansion board based on the NEC uPD720102 chipset containing 3 external and 1 internal USB sockets. It's also hosting a 1.44Mb floppy drive on FDD0, a new 80Gb Western Digital hard drive running as master on IDE0 and a Panasonic DVD+/-RW running as master on IDE1. All this is sitting in a slimline case running off a Macron Power MPT-135 135W Flex power supply. The motherboard is running a version of Award BIOS 05/24/2002-601T-686B-6A6LID4AC-00. Could this be updated? If so, from where? I've raked through the manufacturer's website but can't find any hint of downloads for either drivers or BIOS updates. The hard disk is freshly formatted and built with Windows XP Professional/Service Pack 3 and is up to date with all current patches. In addition to Windows XP, the only other software it's running is Skype 4.1 (4.2 hangs the whole machine as soon as it starts up, requiring a hard boot to recover). It's got a Daytek MV150 15" touch screen hooked up to the on board VGA and COM1 sockets with the most current drivers from the Daytek website and the most current version of ELO-Touchsystems drivers for the touch component. The webcam is a Logitech Webcam C200 with the latest drivers from the Logitech website. The problem: If I hook any devices to the USB 2.0 sockets, it hangs the whole machine and I have to hard boot it to get it back up. If I have any devices attached to the USB 2.0 sockets when I boot up, it hangs before Windows gets to the login prompt and I have to hard boot it to recover. Workarounds found: I can plug the same devices into the on board USB 1.0 sockets and everything works fine, albeit at reduced performance. I've tried 3 different kinds of USB thumb drives, 3 different makes/models of webcams and my iPhone all with the same effect. They're recognized and don't hang the machine when I hook them to the USB 1.0 but if I hook them to the USB 2.0 ports, the machine hangs within a couple of seconds of recognizing the devices were connected. Attempted solutions: I've seen suggestions that this could be a power problem - that the PSU just doesn't have the wattage to drive these ports. While I'm doubtful this is the problem [after all the motherboard has the same standard connector regardless of the PSU wattage], I tried disabling all the on board devices that I'm not using - on board LAN, the second COM port, the AGP connector etc. through the BIOS in what I'm sure is a futile attempt to reduce the power consumption... I also modified the ACPI and power management settings. It didn't have any noticeable affect, although it didn't do any harm either. Could the wattage of the PSU really cause this problem? If it can, is there anything I need to be aware of when replacing it or do I just need to make sure it's got a higher wattage than the current one? My interpretation was that the wattage only affected the number of drives you could hook up to the power connectors, is that right? I've installed the USB card in another machine and it works without issue, so it's not a problem with the USB card itself, and Windows says the card is installed and working correctly... right up until I connect a device to it. The only thing I haven't done which I only just thought of while writing this essay is trying the USB 2.0 card in a different PCI slot, or re-ordering the wi-fi and USB cards in the slots... although I'm not sure if this will make any difference - does anyone have any experience that would suggest this might work? Other thoughts/questions: Perhaps this is an incompatibility between the USB 2.0 card and the BIOS, would re-flashing the BIOS with a newer version help? Do I need to be able to identify the manufacturer of the motherboard in order to be able to find a BIOS edition specific for this motherboard or will any version of Award BIOS function in its place? Question: Does anyone have any ideas that could help me get my USB 2.0 devices hooked up to this machine?

    Read the article

  • Making an animated taskbar app

    - by CasperT
    Hi. I have a HP notebook (running XP). I have seen on IBM computers, that they have a power-meter (it looks like a bar). It displays percentage of power left in battery. It is displayed in the taskbar. Not in the systemtray. Either on the left side or the right side of the potential language toolbar. The application is animated, since the percentage of power (0-100%) chances. It fills up the bar with a green color according to the percentage. So half would be colored green if the power is down to 50%. Now, since it is an IBM application for IBM notebooks, I want/need to make a copy of it. My real question is though, how do I make an animated taskbar application?

    Read the article

  • Optimal two variable linear regression SQL statement (censoring outliers)

    - by Dave Jarvis
    Problem Am looking to apply the y = mx + b equation (where m is SLOPE, b is INTERCEPT) to a data set, which is retrieved as shown in the SQL code. The values from the (MySQL) query are: SLOPE = 0.0276653965651912 INTERCEPT = -57.2338357550468 SQL Code SELECT ((sum(t.YEAR) * sum(t.AMOUNT)) - (count(1) * sum(t.YEAR * t.AMOUNT))) / (power(sum(t.YEAR), 2) - count(1) * sum(power(t.YEAR, 2))) as SLOPE, ((sum( t.YEAR ) * sum( t.YEAR * t.AMOUNT )) - (sum( t.AMOUNT ) * sum(power(t.YEAR, 2)))) / (power(sum(t.YEAR), 2) - count(1) * sum(power(t.YEAR, 2))) as INTERCEPT FROM (SELECT D.AMOUNT, Y.YEAR FROM CITY C, STATION S, YEAR_REF Y, MONTH_REF M, DAILY D WHERE -- For a specific city ... -- C.ID = 8590 AND -- Find all the stations within a 15 unit radius ... -- SQRT( POW( C.LATITUDE - S.LATITUDE, 2 ) + POW( C.LONGITUDE - S.LONGITUDE, 2 ) ) <15 AND -- Gather all known years for that station ... -- S.STATION_DISTRICT_ID = Y.STATION_DISTRICT_ID AND -- The data before 1900 is shaky; insufficient after 2009. -- Y.YEAR BETWEEN 1900 AND 2009 AND -- Filtered by all known months ... -- M.YEAR_REF_ID = Y.ID AND -- Whittled down by category ... -- M.CATEGORY_ID = '001' AND -- Into the valid daily climate data. -- M.ID = D.MONTH_REF_ID AND D.DAILY_FLAG_ID <> 'M' GROUP BY Y.YEAR ORDER BY Y.YEAR ) t Data The data is visualized here (with five outliers highlighted): Questions How do I return the y value against all rows without repeating the same query to collect and collate the data? That is, how do I "reuse" the list of t values? How would you change the query to eliminate outliers (at an 85% confidence interval)? The following results (to calculate the start and end points of the line) appear incorrect. Why are the results off by ~10 degrees (e.g., outliers skewing the data)? (1900 * 0.0276653965651912) + (-57.2338357550468) = -4.66958228 (2009 * 0.0276653965651912) + (-57.2338357550468) = -1.65405406 I would have expected the 1900 result to be around 10 (not -4.67) and the 2009 result to be around 11.50 (not -1.65). Thank you!

    Read the article

  • Optimal two variable linear regression SQL statement

    - by Dave Jarvis
    Problem Am looking to apply the y = mx + b equation (where m is SLOPE, b is INTERCEPT) to a data set, which is retrieved as shown in the SQL code. The values from the (MySQL) query are: SLOPE = 0.0276653965651912 INTERCEPT = -57.2338357550468 SQL Code SELECT ((sum(t.YEAR) * sum(t.AMOUNT)) - (count(1) * sum(t.YEAR * t.AMOUNT))) / (power(sum(t.YEAR), 2) - count(1) * sum(power(t.YEAR, 2))) as SLOPE, ((sum( t.YEAR ) * sum( t.YEAR * t.AMOUNT )) - (sum( t.AMOUNT ) * sum(power(t.YEAR, 2)))) / (power(sum(t.YEAR), 2) - count(1) * sum(power(t.YEAR, 2))) as INTERCEPT FROM (SELECT D.AMOUNT, Y.YEAR FROM CITY C, STATION S, YEAR_REF Y, MONTH_REF M, DAILY D WHERE -- For a specific city ... -- C.ID = 8590 AND -- Find all the stations within a 5 unit radius ... -- SQRT( POW( C.LATITUDE - S.LATITUDE, 2 ) + POW( C.LONGITUDE - S.LONGITUDE, 2 ) ) <15 AND -- Gather all known years for that station ... -- S.STATION_DISTRICT_ID = Y.STATION_DISTRICT_ID AND -- The data before 1900 is shaky; and insufficient after 2009. -- Y.YEAR BETWEEN 1900 AND 2009 AND -- Filtered by all known months ... -- M.YEAR_REF_ID = Y.ID AND -- Whittled down by category ... -- M.CATEGORY_ID = '001' AND -- Into the valid daily climate data. -- M.ID = D.MONTH_REF_ID AND D.DAILY_FLAG_ID <> 'M' GROUP BY Y.YEAR ORDER BY Y.YEAR ) t Data The data is visualized here: Questions How do I return the y value against all rows without repeating the same query to collect and collate the data? That is, how do I "reuse" the list of t values? How would you change the query to eliminate outliers (at an 85% confidence interval)? The following results (to calculate the start and end points of the line) appear incorrect. Why are the results off by ~10 degrees (e.g., outliers skewing the data)? (1900 * 0.0276653965651912) + (-57.2338357550468) = -4.66958228 (2009 * 0.0276653965651912) + (-57.2338357550468) = -1.65405406 I would have expected the 1900 result to be around 10 (not -4.67) and the 2009 result to be around 11.50 (not -1.65). Thank you!

    Read the article

  • Optimal two variable linear regression calculation

    - by Dave Jarvis
    Problem Am looking to apply the y = mx + b equation (where m is SLOPE, b is INTERCEPT) to a data set, which is retrieved as shown in the SQL code. The values from the (MySQL) query are: SLOPE = 0.0276653965651912 INTERCEPT = -57.2338357550468 SQL Code SELECT ((sum(t.YEAR) * sum(t.AMOUNT)) - (count(1) * sum(t.YEAR * t.AMOUNT))) / (power(sum(t.YEAR), 2) - count(1) * sum(power(t.YEAR, 2))) as SLOPE, ((sum( t.YEAR ) * sum( t.YEAR * t.AMOUNT )) - (sum( t.AMOUNT ) * sum(power(t.YEAR, 2)))) / (power(sum(t.YEAR), 2) - count(1) * sum(power(t.YEAR, 2))) as INTERCEPT, FROM (SELECT D.AMOUNT, Y.YEAR FROM CITY C, STATION S, YEAR_REF Y, MONTH_REF M, DAILY D WHERE -- For a specific city ... -- C.ID = 8590 AND -- Find all the stations within a 15 unit radius ... -- SQRT( POW( C.LATITUDE - S.LATITUDE, 2 ) + POW( C.LONGITUDE - S.LONGITUDE, 2 ) ) < 15 AND -- Gather all known years for that station ... -- S.STATION_DISTRICT_ID = Y.STATION_DISTRICT_ID AND -- The data before 1900 is shaky; insufficient after 2009. -- Y.YEAR BETWEEN 1900 AND 2009 AND -- Filtered by all known months ... -- M.YEAR_REF_ID = Y.ID AND -- Whittled down by category ... -- M.CATEGORY_ID = '001' AND -- Into the valid daily climate data. -- M.ID = D.MONTH_REF_ID AND D.DAILY_FLAG_ID <> 'M' GROUP BY Y.YEAR ORDER BY Y.YEAR ) t Data The data is visualized here: Question The following results (to calculate the start and end points of the line) appear incorrect. Why are the results off by ~10 degrees (e.g., outliers skewing the data)? (1900 * 0.0276653965651912) + (-57.2338357550468) = -4.66958228 (2009 * 0.0276653965651912) + (-57.2338357550468) = -1.65405406 I would have expected the 1900 result to be around 10 (not -4.67) and the 2009 result to be around 11.50 (not -1.65). Related Sites Least absolute deviations Robust regression Thank you!

    Read the article

  • Remove redundant SQL code

    - by Dave Jarvis
    Code The following code calculates the slope and intercept for a linear regression against a slathering of data. It then applies the equation y = mx + b against the same result set to calculate the value of the regression line for each row. Can the two separate sub-selects be joined so that the data and its slope/intercept are calculated without executing the data gathering part of the query twice? SELECT AVG(D.AMOUNT) as AMOUNT, Y.YEAR * ymxb.SLOPE + ymxb.INTERCEPT as REGRESSION_LINE, Y.YEAR as YEAR, MAKEDATE(Y.YEAR,1) as AMOUNT_DATE FROM CITY C, STATION S, YEAR_REF Y, MONTH_REF M, DAILY D, (SELECT ((avg(t.AMOUNT * t.YEAR)) - avg(t.AMOUNT) * avg(t.YEAR)) / (stddev( t.AMOUNT ) * stddev( t.YEAR )) as CORRELATION, ((sum(t.YEAR) * sum(t.AMOUNT)) - (count(1) * sum(t.YEAR * t.AMOUNT))) / (power(sum(t.YEAR), 2) - count(1) * sum(power(t.YEAR, 2))) as SLOPE, ((sum( t.YEAR ) * sum( t.YEAR * t.AMOUNT )) - (sum( t.AMOUNT ) * sum(power(t.YEAR, 2)))) / (power(sum(t.YEAR), 2) - count(1) * sum(power(t.YEAR, 2))) as INTERCEPT FROM ( SELECT AVG(D.AMOUNT) as AMOUNT, Y.YEAR as YEAR, MAKEDATE(Y.YEAR,1) as AMOUNT_DATE FROM CITY C, STATION S, YEAR_REF Y, MONTH_REF M, DAILY D WHERE $X{ IN, C.ID, CityCode } AND SQRT( POW( C.LATITUDE - S.LATITUDE, 2 ) + POW( C.LONGITUDE - S.LONGITUDE, 2 ) ) < $P{Radius} AND S.STATION_DISTRICT_ID = Y.STATION_DISTRICT_ID AND Y.YEAR BETWEEN 1900 AND 2009 AND M.YEAR_REF_ID = Y.ID AND M.CATEGORY_ID = $P{CategoryCode} AND M.ID = D.MONTH_REF_ID AND D.DAILY_FLAG_ID <> 'M' GROUP BY Y.YEAR ) t ) ymxb WHERE $X{ IN, C.ID, CityCode } AND SQRT( POW( C.LATITUDE - S.LATITUDE, 2 ) + POW( C.LONGITUDE - S.LONGITUDE, 2 ) ) < $P{Radius} AND S.STATION_DISTRICT_ID = Y.STATION_DISTRICT_ID AND Y.YEAR BETWEEN 1900 AND 2009 AND M.YEAR_REF_ID = Y.ID AND M.CATEGORY_ID = $P{CategoryCode} AND M.ID = D.MONTH_REF_ID AND D.DAILY_FLAG_ID <> 'M' GROUP BY Y.YEAR Question How do I execute the duplicate bits only once per query, instead of twice? The duplicate bit is the WHERE clause: $X{ IN, C.ID, CityCode } AND SQRT( POW( C.LATITUDE - S.LATITUDE, 2 ) + POW( C.LONGITUDE - S.LONGITUDE, 2 ) ) < $P{Radius} AND S.STATION_DISTRICT_ID = Y.STATION_DISTRICT_ID AND Y.YEAR BETWEEN 1900 AND 2009 AND M.YEAR_REF_ID = Y.ID AND M.CATEGORY_ID = $P{CategoryCode} AND M.ID = D.MONTH_REF_ID AND D.DAILY_FLAG_ID <> 'M' Related http://stackoverflow.com/questions/1595659/how-to-eliminate-duplicate-calculation-in-sql Thank you!

    Read the article

  • How do I get a rt2800usb wireless device working?

    - by Jii
    My brand new desktop running 13.04 has endless problems with wireless. Dozens of others are flooding forums with reports of the same problems. It worked fine for a few days, then there were a few days where it started having problems sometimes and working sometimes. Now it never works at all. I have 5+ devices all able to connect without any trouble at all, including iPhone, Android phone, 3DS, multiple game consoles, a laptop running windows 7, and even a second desktop machine running Ubuntu 12.04 sitting right behind the 13.04 machine. All other devices have full wireless bars displayed (strong signals). At any moment, one of the following is happening, and it changes randomly: Trying to connect forever, but never establishing a connection. Wireless icon constantly animating. Finds no wireless networks at all. (There are 12+ in range according to other devices.) Will not try to connect to the network. If I use the icon to connect, it will display "Disconnected" within a few seconds. Will continuously ask for the network password. Typing it in correctly does not help. Wireless is working fine. This happens sometimes. It can work for days at a time, or only 10 mins at a time. Various things that usually do nothing but sometimes fix the problem: Reboot. This has the best chance of helping, but it usually takes 5+ times. Disable/re-enable Wi-Fi using the wireless icon. Disable/re-enable Networking using the wireless icon. Use the icon to try and connect to a network (if found). Use the icon to open Edit Connections and delete my connection info, causing it to be recreated (once it's actually found again). Various things that seem to make no difference: Changing between using Linux headers in grub at bootup, between 3.10.0, 3.9.0, or 3.8.0. Move the wireless router very close to the desktop. Running sudo rfkill unblock all (I dunno what this is supposed to do.) I've used Ubuntu for 6 years and I've never had a problem with networking. Now I'm spending all my time reading through endless problem reports and trying all the answers. None of them have helped. I am doing this instead of getting work done, which is defeating the whole purpose of using Ubuntu. It's heartbreaking to be honest. In the current state of "no networks are showing up", here are outputs from the random things that other people are usually asked to run: lspic 00:00.0 Host bridge: Intel Corporation Haswell DRAM Controller (rev 06) 00:01.0 PCI bridge: Intel Corporation Haswell PCI Express x16 Controller (rev 06) 00:14.0 USB controller: Intel Corporation Lynx Point USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation Lynx Point MEI Controller #1 (rev 04) 00:19.0 Ethernet controller: Intel Corporation Ethernet Connection I217-V (rev 04) 00:1a.0 USB controller: Intel Corporation Lynx Point USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation Lynx Point High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation Lynx Point PCI Express Root Port #1 (rev d4) 00:1c.2 PCI bridge: Intel Corporation 82801 PCI Bridge (rev d4) 00:1d.0 USB controller: Intel Corporation Lynx Point USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation Lynx Point LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation Lynx Point 6-port SATA Controller 1 [AHCI mode] (rev 04) 00:1f.3 SMBus: Intel Corporation Lynx Point SMBus Controller (rev 04) 01:00.0 VGA compatible controller: NVIDIA Corporation GF119 [GeForce GT 610] (rev a1) 01:00.1 Audio device: NVIDIA Corporation GF119 HDMI Audio Controller (rev a1) 03:00.0 PCI bridge: ASMedia Technology Inc. ASM1083/1085 PCIe to PCI Bridge (rev 03) lsmod Module Size Used by e100 41119 0 nls_iso8859_1 12713 1 parport_pc 28284 0 ppdev 17106 0 bnep 18258 2 rfcomm 47863 12 binfmt_misc 17540 1 arc4 12573 2 rt2800usb 27201 0 rt2x00usb 20857 1 rt2800usb rt2800lib 68029 1 rt2800usb rt2x00lib 55764 3 rt2x00usb,rt2800lib,rt2800usb coretemp 13596 0 mac80211 656164 3 rt2x00lib,rt2x00usb,rt2800lib kvm_intel 138733 0 kvm 452835 1 kvm_intel cfg80211 547224 2 mac80211,rt2x00lib crc_ccitt 12707 1 rt2800lib ghash_clmulni_intel 13259 0 aesni_intel 55449 0 usb_storage 61749 1 aes_x86_64 17131 1 aesni_intel joydev 17613 0 xts 12922 1 aesni_intel nouveau 1001310 3 snd_hda_codec_hdmi 37407 1 lrw 13294 1 aesni_intel gf128mul 14951 2 lrw,xts mxm_wmi 13021 1 nouveau snd_hda_codec_realtek 46511 1 ablk_helper 13597 1 aesni_intel wmi 19256 2 mxm_wmi,nouveau snd_hda_intel 44397 5 ttm 88251 1 nouveau drm_kms_helper 49082 1 nouveau drm 295908 5 ttm,drm_kms_helper,nouveau snd_hda_codec 190010 3 snd_hda_codec_realtek,snd_hda_codec_hdmi,snd_hda_intel cryptd 20501 3 ghash_clmulni_intel,aesni_intel,ablk_helper snd_hwdep 13613 1 snd_hda_codec snd_pcm 102477 3 snd_hda_codec_hdmi,snd_hda_codec,snd_hda_intel btusb 18291 0 snd_page_alloc 18798 2 snd_pcm,snd_hda_intel snd_seq_midi 13324 0 i2c_algo_bit 13564 1 nouveau snd_seq_midi_event 14899 1 snd_seq_midi snd_rawmidi 30417 1 snd_seq_midi snd_seq 61930 2 snd_seq_midi_event,snd_seq_midi bluetooth 251354 22 bnep,btusb,rfcomm snd_seq_device 14497 3 snd_seq,snd_rawmidi,snd_seq_midi lpc_ich 17060 0 snd_timer 29989 2 snd_pcm,snd_seq mei 46588 0 snd 69533 20 snd_hda_codec_realtek,snd_hwdep,snd_timer,snd_hda_codec_hdmi,snd_pcm,snd_seq,snd_rawmidi,snd_hda_codec,snd_hda_intel,snd_seq_device psmouse 97838 0 microcode 22923 0 soundcore 12680 1 snd video 19467 1 nouveau mac_hid 13253 0 serio_raw 13215 0 lp 17799 0 parport 46562 3 lp,ppdev,parport_pc hid_generic 12548 0 usbhid 47346 0 hid 101248 2 hid_generic,usbhid ahci 30063 3 libahci 32088 1 ahci e1000e 207005 0 ptp 18668 1 e1000e pps_core 14080 1 ptp sudo lshw -c network 00:00.0 Host bridge: Intel Corporation Haswell DRAM Controller (rev 06) 00:01.0 PCI bridge: Intel Corporation Haswell PCI Express x16 Controller (rev 06) 00:14.0 USB controller: Intel Corporation Lynx Point USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation Lynx Point MEI Controller #1 (rev 04) 00:19.0 Ethernet controller: Intel Corporation Ethernet Connection I217-V (rev 04) 00:1a.0 USB controller: Intel Corporation Lynx Point USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation Lynx Point High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation Lynx Point PCI Express Root Port #1 (rev d4) 00:1c.2 PCI bridge: Intel Corporation 82801 PCI Bridge (rev d4) 00:1d.0 USB controller: Intel Corporation Lynx Point USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation Lynx Point LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation Lynx Point 6-port SATA Controller 1 [AHCI mode] (rev 04) 00:1f.3 SMBus: Intel Corporation Lynx Point SMBus Controller (rev 04) 01:00.0 VGA compatible controller: NVIDIA Corporation GF119 [GeForce GT 610] (rev a1) 01:00.1 Audio device: NVIDIA Corporation GF119 HDMI Audio Controller (rev a1) 03:00.0 PCI bridge: ASMedia Technology Inc. ASM1083/1085 PCIe to PCI Bridge (rev 03) sudo iwconfig eth0 no wireless extensions. lo no wireless extensions. wlan0 IEEE 802.11bgn ESSID:off/any Mode:Managed Access Point: Not-Associated Tx-Power=20 dBm Retry long limit:7 RTS thr:off Fragment thr:off Encryption key:off Power Management:on sudo iwlist scan eth0 Interface doesn't support scanning. lo Interface doesn't support scanning. wlan0 No scan results NOTE: This dmesg was done after a reboot where the network manager was continuously displaying the "disconnected" message over and over. So it must have been trying to connect at this time. My network was displayed in the list of options, as the only option despite other devices picking up 12+ access points. The router channel is set to auto. dmesg | tail -30 [ 187.418446] wlan0: associated [ 190.405601] wlan0: disassociated from 00:14:d1:a8:c3:44 (Reason: 15) [ 190.443312] cfg80211: Calling CRDA to update world regulatory domain [ 190.443431] wlan0: deauthenticating from 00:14:d1:a8:c3:44 by local choice (reason=3) [ 190.451635] cfg80211: World regulatory domain updated: [ 190.451643] cfg80211: (start_freq - end_freq @ bandwidth), (max_antenna_gain, max_eirp) [ 190.451648] cfg80211: (2402000 KHz - 2472000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 190.451652] cfg80211: (2457000 KHz - 2482000 KHz @ 20000 KHz), (300 mBi, 2000 mBm) [ 190.451656] cfg80211: (2474000 KHz - 2494000 KHz @ 20000 KHz), (300 mBi, 2000 mBm) [ 190.451659] cfg80211: (5170000 KHz - 5250000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 190.451662] cfg80211: (5735000 KHz - 5835000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 191.824451] wlan0: authenticate with 00:14:d1:a8:c3:44 [ 191.850608] wlan0: send auth to 00:14:d1:a8:c3:44 (try 1/3) [ 191.884604] wlan0: send auth to 00:14:d1:a8:c3:44 (try 2/3) [ 191.886309] wlan0: authenticated [ 191.886579] rt2800usb 3-5.3:1.0 wlan0: disabling HT as WMM/QoS is not supported by the AP [ 191.886588] rt2800usb 3-5.3:1.0 wlan0: disabling VHT as WMM/QoS is not supported by the AP [ 191.889556] wlan0: associate with 00:14:d1:a8:c3:44 (try 1/3) [ 192.001493] wlan0: associate with 00:14:d1:a8:c3:44 (try 2/3) [ 192.040274] wlan0: RX AssocResp from 00:14:d1:a8:c3:44 (capab=0x431 status=0 aid=3) [ 192.044235] wlan0: associated [ 193.948188] wlan0: deauthenticating from 00:14:d1:a8:c3:44 by local choice (reason=3) [ 193.981501] cfg80211: Calling CRDA to update world regulatory domain [ 193.984080] cfg80211: World regulatory domain updated: [ 193.984082] cfg80211: (start_freq - end_freq @ bandwidth), (max_antenna_gain, max_eirp) [ 193.984084] cfg80211: (2402000 KHz - 2472000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 193.984085] cfg80211: (2457000 KHz - 2482000 KHz @ 20000 KHz), (300 mBi, 2000 mBm) [ 193.984085] cfg80211: (2474000 KHz - 2494000 KHz @ 20000 KHz), (300 mBi, 2000 mBm) [ 193.984086] cfg80211: (5170000 KHz - 5250000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 193.984087] cfg80211: (5735000 KHz - 5835000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) The router uses MAC filtering, and security is WPA PSK with cipher as auto. So, any ideas? Or is the solution just to not use 13.04 unless you have a wired connection? (I don't have this option.) If so, please just tell me straight. I survived 9.04 Jaunty, and I can survive 13.04 Raring. Update #1 Results from trying Wild Man's first answer: jii@conan:~$ echo "options rt2800usb nohwcrypt=y" | sudo tee /etc/modprobe.d/rt2800usb.conf options rt2800usb nohwcrypt=y jii@conan:~$ sudo modprobe -rfv rt2800usb rmmod rt2800usb rmmod rt2800lib rmmod crc_ccitt rmmod rt2x00usb rmmod rt2x00lib rmmod mac80211 rmmod cfg80211 jii@conan:~$ sudo modprobe -v rt2800usb insmod /lib/modules/3.10.0-031000-generic/kernel/lib/crc-ccitt.ko insmod /lib/modules/3.10.0-031000-generic/kernel/net/wireless/cfg80211.ko insmod /lib/modules/3.10.0-031000-generic/kernel/net/mac80211/mac80211.ko insmod /lib/modules/3.10.0-031000-generic/kernel/drivers/net/wireless/rt2x00/rt2x00lib.ko insmod /lib/modules/3.10.0-031000-generic/kernel/drivers/net/wireless/rt2x00/rt2800lib.ko insmod /lib/modules/3.10.0-031000-generic/kernel/drivers/net/wireless/rt2x00/rt2x00usb.ko insmod /lib/modules/3.10.0-031000-generic/kernel/drivers/net/wireless/rt2x00/rt2800usb.ko nohwcrypt=y I tried: gksudo gedit /etc/pm/power.d/wireless but I didn't have the package. It said to install gksu. I tried that, but of course, not having Internet, I didn't get the package. So instead I did: sudo gedit /etc/pm/power.d/wireless Which created the file. Here is the body: #!/bin/sh /sbin/iwconfig wlan0 power off I then rebooted. No change. I tried adding exit 0 to the bottom of the wireless file, and rebooted. No change. Please note that this is a desktop machine. I'm assuming power management is primarily for laptops, but the iwconfig does state that power management is on, so who knows. The recommended router changes I did not do, since the current router settings are (I think) required for some of the older devices I have, and because the current settings work on all my modern devices including Ubuntu 12.04 and Windows 7. I do appreciate the advice though, and I'll look into it when I have time. Anything else to try? Update #2 I booted into Ubuntu 12.04.3 from a dvd, and the same problems exist. I have a separate old desktop machine with 12.04 installed that has no wireless problems at all. So obviously the problem is wireless hardware compatibility in both 12.04.03 LTS and 13.04. Update #3 The same problems exist even when using a wired connection. I plugged an ethernet cable directly to the router and the network manager added an "Auto Ethernet" entry, but it cannot establish a connection to it. So the problem is not specific to wireless. Meanwhile, I purchased a Trendnet N300 wireless USB adapter, TEW-664UB. I plugged it in, but I have no idea how to get Ubuntu to try and use it. Can anyone tell me how? Can I download a package on another computer and copy the .deb over to do an install, etc? I'm installing windows 7 to double check that the internet connection works there and it's not just some magically faulty hardware. Thanks for your help.

    Read the article

  • Can't view database on SQL Server 2008 with domain user

    - by abatishchev
    I created a login for a domain user (domain admin) and added it to role serveradmin, but after logging in I still can't list databases getting next error: The database MyDB is not accessible. (ObjectExplorer) Program Location: at Microsoft.SqlServer.Management.UI.VSIntegration.ObjectExplorer.DatabaseNavigableItem.get_CanGetChildren() at Microsoft.SqlServer.Management.UI.VSIntegration.ObjectExplorer.NavigableItem.GetChildren(IGetChildrenRequest request) at Microsoft.SqlServer.Management.UI.VSIntegration.ObjectExplorer.ExplorerHierarchyNode.BuildChildren(WaitHandle quitEvent) How can I fix that?

    Read the article

  • Connect over WiFi to SQL Server from another computer

    - by Bronzato
    I tried to connect over WiFi to SQL Server with SQL Server Management Studio from another computer, but it failed. I have a computer with Windows 7 & SQL Server 2008 (lets say the server computer). Next to it I have a freshly installed computer with Windows 7 & SQL Server Management Studio (let's say the client computer). What I did on the server computer: Configure firewall by enabling port 1433 Enabled network protocols (TCP/IP) inside SQL Server Configuration Manager Checked Allow remote connections to this server in server properties in the SQL Server Management application. Started SQL Server Browser Restarted services (SQL Server Browser is stopped at this point, but I don't think it is necessary. Is it?) Next, I successfully tested a ping on the port 1433 from my client computer with a tool named tcping (ex: tcping 192.168.1.4 1433). But I still cannot connect from my client computer to SQL Server on my server computer. Ok, something new with this problem: Until now, I successfully connected to my "server computer" with Management Studio. What I did is type the computer name in the server name field in the connection window of Management Studio. My previous (failed) attempt was to type the computer name followed by the instance of SQL server (ex: COMPUTER_NAME\SQL2008). I don't know why I only have to type the computer name. Now my new challenge is to be successful in connecting my VB6 application to this remote database located on my "server computer". I have a connection string for this but it failed to connect. Here is my connection string: "Provider=SQLOLEDB.1;Password=mypassword;User ID=sa;Initial Catalog=TPB;Data Source=THIERRY-HP\SQL2008" Any idea what's going wrong?

    Read the article

  • Performing mechanical movements using computer

    - by Vi
    How to make a computer (in particular, my laptop) to perform some mechanical movements without buying anything $5, soldering things inside computer or creating big sophisticated circuits? Traditionally CD-ROM tray is used to make computer do some movement IRL by, for example, SSH command, but in laptop tray is one-shot (unless manually reloaded) and also not very comfortable [mis]usage. Some assistance circuits can be in use too, but not complex. For example, there is a little motor that can work on USB power. Devices in my computer: DVD-ROM tray: one-time push. USB power: continuous power to the motor or LEDS or relay that turns on something powerful. Audio card. 3 outputs (modprobe alsa model=test can set Mic and Line-in as additional output). One controllable DC output (microphone) that can power up LED and some electronic (may be even mechanic?) relay. Also with sophisticated additional circuiting can control a lot of devices with a good precision. Both input and output support. Probably the most useful object in computer for radio ham. Modem. Don't know about this much, it doesn't work because of hsfmodem crashes kernel if memory is = 1GB. May be it's "pick up" and "hang up" can turn on and off power taken from USB port? Video card. VGA port? S-Video port? Will them be useful? Backlight. Tunable, but probably unuseful. CardBus (or some) slot. Nothing interesting for the task probably (is it?). AC adapter and battery. Probably nothing programmable here. /* My AC adapter already have additional jacks to connect extra devics */ Keyboard. No use. Touchpad. Good sensor (synclient -m 1), but no output. Various LEDs inside laptop. Probably too weak and requires soldering. Fans inside laptop. Poor control over them, requires soldering and dangerous to tinker. HDD (internal and external) that can be spin down and up (hdparm -Y, cat /dev/ubb). But connecting anything serially with it's power line makes HDD underpowered... And too complex. Is something are missed? Any ideas how to use described components? Any other ideas? May be there are easily available /* in developing countries */ cheap devices like "enhanced multimeters" that are controllable from computer and can provide configurable output and measure current and other things? Things to aid pushing many physical buttons with computer. Isn't this a simple idea and implementation and a lot of use in good hands?

    Read the article