Search Results

Search found 24211 results on 969 pages for 'shell command'.

Page 223/969 | < Previous Page | 219 220 221 222 223 224 225 226 227 228 229 230  | Next Page >

  • Why is only one wget command working in my crontab?

    - by afEkenholm
    I wish to fetch content from a PHP script on my server two times a day, altering a query variable lang to set what language we want, and save this content in two language specific files. This is my crontab: */15 * * * * ~root/apache.sh > /var/log/checkapache.log 10 0 * * * wget -O /path/to/file-sv.sql "http://mydomain.com/path/?lang=sv" 11 0 * * * wget -O /path/to/file-en.sql "http://mydomain.com/path/?lang=en" The problem is that only the first wget command line is being executed (or to be precise: the only file that is being written is /path/to/file-sv.sql). If I switch the second and the third row, /path/to/file-en.sql gets written instead. The first line always runs as expected, no matter where it is. I then tried using lynx -dump "http://mydomain.com/path/?lang=xx" > /path/to/file-xx.sql to no avail; still only the first lynx line executed successfully. Even mixing wget and lynx did not change this! Getting kinda desperate! Am I missing something? There are thousands of articles on crontab (combined with) wget or lynx, but all seems to cover basic setups and syntax. Does anyone got a clue of what I am doing wrong? Thanks, Alexander

    Read the article

  • How can I launch a GUI session on a remote Ubuntu Desktop via SSH from a non-GUI Linux shell?

    - by Vihung
    I am setting up a test environment, made up of various Linux boxes, and I have the need to launch an instance of Firefox on a remote machine via ssh. The remote machine has Ubuntu Desktop (11) and Firefox installed. The source machine is a Continuous Integration server and it creates an ssh session to the remote machine from a non-GUI environment. It then runs a script, which tries to launch Firefox on the remote machine. However, since the ssh session is a from a non-GUI environment, there is no display. Is it possible to have a headless X-windows display? i.e. a virtual display in the remote environment for Firefox to run in? What options do I have?

    Read the article

  • How do I add the "Date Created" sort-by option to the shell in Windows 7?

    - by Daniel
    I know how to add it via the context menu, but it never seems to be a permanent option. I would like it to show in all folders without having to continually go back through and add it. How can I make Windows Explorer show file modified date instead of created date? I've looked at this question, so I assume it is the same as going through the context menu seen by right clicking inside the folder.

    Read the article

  • Is it possible to command a common router without using the web interface?

    - by MDeSchaepmeester
    Some background The internet arrangement in my student home is really weird. There is one ethernet outlet and several wifi hotspots. Either way requires a login through a web site to get internet access. This is annoying as each device needs to login seperately and with a PS3 for example, it is impossible to get connected at all since the web login procedure doesn't work. Therefore I have installed a D-Link DIR-635 router which is connected to the ethernet outlet. It has DHCP enabled so it uses NAT, but whatever it is connected to also uses NAT and I've read this should not work. A fellow student tried it with an Apple Airport but that keeps giving errors related to NAT after NAT. Anyway my setup does work so bonus points if you can clarify this. I need to login to the web site I mentioned earlier with any device, after which all devices in my LAN have connectivity. This is great. Except... In short From time to time, I lose internet connectivity and my D-Link DIR-635 router needs to do a DHCP renew. I can do this via the web interface but my life would be easier if I could just run a cmd file which tells my router to do this without all the hassle. This would setup a connection to my router and execute the proper command. I have tried googling but couldn't find much helpful stuff.

    Read the article

  • Odd one: IE6 showing the "view source" command enabled when I was expecting it to be disabled.

    - by caerphilly
    Hi, OK, I admit this problem is odd. I'm just trying to understand why IE is behaving the way it is. I realise that logic may not apply here :) I have Internet Explorer 6 (Sp1) running on Windows 2000. The IE option "Do not store encrypted pages to disk" is checked (enabled). The temporary internet files folder is empty. TEMP and TMP environment variables are set to valid folders. I'm connected to a web server over SSL. The web server is serving a page over SSL with the HTTP cache-control header set to "no-cache, no-store". I was expecting the "view source" command to be greyed out in this circumstance (as it is on another machine). But it works. When I "view source", I get an entry in the Temporary Internet Files folder with an "internet address" property of "view-source:https://myserver/...." and the content of the page. I wasn't expecting that. I can't understand why one machine is different to another in this regard. Obviously there is some environment/setup difference, but I can't track it down. Anyone have any bright ideas?

    Read the article

  • Windows 8 power-shell "update-help" is failing. Does anyone know how to fix it?

    - by Warren P
    Windows 8 includes PowerShell out of the box, but not the help. To get the help you run PowerShell as administrator and type "update-help". I get this error: > update-help update-help : Failed to update Help for the module(s) 'BitLocker, NetWNV' with UI culture(s) {en-US} : The value of the HelpInfoUri key in the module manifest must resolve to a container or root URL on a website where the help files are stored. The HelpInfoUri 'http://technet.microsoft.com/library/cc732148.aspx' does not resolve to a container. At line:1 char:1 + update-help + ~~~~~~~~~~~ + CategoryInfo : InvalidOperation: (:) [Update-Help], Exception + FullyQualifiedErrorId : InvalidHelpInfoUri,Microsoft.PowerShell.Commands.UpdateHelpCommand Can anyone tell me how I fix this or if it's not important? I'm guessing that if I don't need help on NetWNV or BitLocker, that this is the only thing wrong?

    Read the article

  • Run shell script on Linux box from a shortcut/app in Android?

    - by melat0nin
    I have an Ubuntu box which runs XBMC, which crashes occasionally. Since I have no keyboard connected,I have to SSH in, kill xinit, then restart it. I was wondering if there's an elegant way of doing this from my Android tablet, so I don't have to go to my desktop PC. I've used ConnectBot and can log in, but typing is laborious, even using the edit keys to scroll back up through the buffer. It seems as though it should be possible to script this so that I can execute a shortcut, or at least select a predefined script to be executed. This would seem to have plenty of applications, and there could be a site of scripts - restart webserver, reboot, email logs etc

    Read the article

  • Can you explain how to understand what the 'iwconfig' command displays in Ubuntu-9.04?

    - by Shawn
    I'm having trouble making my wireless connection work, and I realized I don't really know how to use the tools I have, in this case, the iwconfig command in Ubuntu-9.04. Here is what I get: ***iwconfig*** - lo no wireless extensions. eth0 no wireless extensions. wmaster0 no wireless extensions. wlan0 IEEE 802.11bgn ESSID:"Network" Mode:Managed Frequency:2.412 GHz Access Point: Not-Associated Tx-Power=20 dBm Retry min limit:7 RTS thr:off Fragment thr=2352 B Power Management:off Link Quality:0 Signal level:0 Noise level:0 Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:0 Missed beacon:0 vboxnet0 no wireless extensions. pan0 no wireless extensions. "Network" is the name of my wireless network, btw. But what does this all mean? How can this information help me aquire a working wireless connection? When I try associating a key using sudo iwconfig wlan0 key s:my_key I get the following error message: Error for wireless request "Set Encode" (8B2A) : SET failed on device wlan0 ; Invalid argument. I do have the right key though, so what's the problem?

    Read the article

  • Can you explain how to understand what the 'iwconfig' command displays in Ubuntu-9.04?

    - by Shawn
    I'm having trouble making my wireless connection work, and I realized I don't really know how to use the tools I have, in this case, the iwconfig command in Ubuntu-9.04. Here is what I get: ***iwconfig*** - lo no wireless extensions. eth0 no wireless extensions. wmaster0 no wireless extensions. wlan0 IEEE 802.11bgn ESSID:"Network" Mode:Managed Frequency:2.412 GHz Access Point: Not-Associated Tx-Power=20 dBm Retry min limit:7 RTS thr:off Fragment thr=2352 B Power Management:off Link Quality:0 Signal level:0 Noise level:0 Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:0 Missed beacon:0 vboxnet0 no wireless extensions. pan0 no wireless extensions. "Network" is the name of my wireless network, btw. But what does this all mean? How can this information help me aquire a working wireless connection? When I try associating a key using sudo iwconfig wlan0 key s:my_key I get the following error message: Error for wireless request "Set Encode" (8B2A) : SET failed on device wlan0 ; Invalid argument. I do have the right key though, so what's the problem?

    Read the article

  • Xubuntu Terminal overrides shell- and vi color schemes, how to deactivate?

    - by erikb85
    I'm running an up-to-tade Xubuntu and have a real problem with these Terminals. I don't want them to be all that design-ish. Just the plain old Terminal with a black background and green text. And in VIM I want to use my own color scheme. But the xfce-4-terminal doesn't seem to let me do that. It always uses it's own color schemes and they just don't work for all cases (you have like 6 different types of text elements to color, for coding you need more). How can I disable the coloring in the terminal or just load a simple one without all these features?

    Read the article

  • Checking who is connected to your server, with PowerShell.

    - by Fatherjack
    There are many occasions when, as a DBA, you want to see who is connected to your SQL Server, along with how they are connecting and what sort of activities they are carrying out. I’m going to look at a couple of ways of getting this information and compare the effort required and the results achieved of each. SQL Server comes with a couple of stored procedures to help with this sort of task – sp_who and its undocumented counterpart sp_who2. There is also the pumped up version of these called sp_whoisactive, written by Adam Machanic which does way more than these procedures. I wholly recommend you try it out if you don’t already know how it works. When it comes to serious interrogation of your SQL Server activity then it is absolutely indispensable. Anyway, back to the point of this blog, we are going to look at getting the information from sp_who2 for a remote server. I wrote this Powershell script a week or so ago and was quietly happy with it for a while. I’m relatively new to Powershell so forgive both my rather low threshold for entertainment and the fact that something so simple is a moderate achievement for me. $Server = 'SERVERNAME' $SMOServer = New-Object Microsoft.SQLServer.Management.SMO.Server $Server # connection and query stuff         $ConnectionStr = "Server=$Server;Database=Master;Integrated Security=True" $Query = "EXEC sp_who2" $Connection = new-object system.Data.SQLClient.SQLConnection $Table = new-object "System.Data.DataTable" $Connection.connectionstring = $ConnectionStr try{ $Connection.open() $Command = $Connection.CreateCommand() $Command.commandtext = $Query $result = $Command.ExecuteReader() $Table.Load($result) } catch{ # Show error $error[0] | format-list -Force } $Title = "Data access processes (" + $Table.Rows.Count + ")" $Table | Out-GridView -Title $Title $Connection.close() So this is pretty straightforward, create an SMO object that represents our chosen server, define a connection to the database and a table object for the results when we get them, execute our query over the connection, load the results into our table object and then, if everything is error free display these results to the PowerShell grid viewer. The query simply gets the results of ‘EXEC sp_who2′ for us. Depending on how many connections there are will influence how long the query runs. The grid viewer lets me sort and search the results so it can be a pretty handy way to locate troublesome connections. Like I say, I was quite pleased with this, it seems a pretty simple script and was working well for me, I have added a few parameters to control the output and give me more specific details but then I see a script that uses the $SMOServer object itself to provide the process information and saves having to define the connection object and query specifications. $Server = 'SERVERNAME' $SMOServer = New-Object Microsoft.SQLServer.Management.SMO.Server $Server $Processes = $SMOServer.EnumProcesses() $Title = "SMO processes (" + $Processes.Rows.Count + ")" $Processes | Out-GridView -Title $Title Create the SMO object of our server and then call the EnumProcesses method to get all the process information from the server. Staggeringly simple! The results are a little different though. Some columns are the same and we can see the same basic information so my first thought was to which runs faster – so that I can get my results more quickly and also so that I place less stress on my server(s). PowerShell comes with a great way of testing this – the Measure-Command function. All you have to do is wrap your piece of code in Measure-Command {[your code here]} and it will spit out the time taken to execute the code. So, I placed both of the above methods of getting SQL Server process connections in two Measure-Command wrappers and pressed F5! The Powershell console goes blank for a while as the code is executed internally when Measure-Command is used but the grid viewer windows appear and the console shows this. You can take the output from Measure-Command and format it for easier reading but in a simple comparison like this we can simply cross refer the TotalMilliseconds values from the two result sets to see how the two methods performed. The query execution method (running EXEC sp_who2 ) is the first set of timings and the SMO EnumProcesses is the second. I have run these on a variety of servers and while the results vary from execution to execution I have never seen the SMO version slower than the other. The difference has varied and the time for both has ranged from sub-second as we see above to almost 5 seconds on other systems. This difference, I would suggest is partly due to the cost overhead of having to construct the data connection and so on where as the SMO EnumProcesses method has the connection to the server already in place and just needs to call back the process information. There is also the difference in the data sets to consider. Let’s take a look at what we get and where the two methods differ Query execution method (sp_who2) SMO EnumProcesses Description - Urn What looks like an XML or JSON representation of the server name and the process ID SPID Spid The process ID Status Status The status of the process Login Login The login name of the user executing the command HostName Host The name of the computer where the  process originated BlkBy BlockingSpid The SPID of a process that is blocking this one DBName Database The database that this process is connected to Command Command The type of command that is executing CPUTime Cpu The CPU activity related to this process DiskIO - The Disk IO activity related to this process LastBatch - The time the last batch was executed from this process. ProgramName Program The application that is facilitating the process connection to the SQL Server. SPID1 - In my experience this is always the same value as SPID. REQUESTID - In my experience this is always 0 - Name In my experience this is always the same value as SPID and so could be seen as analogous to SPID1 from sp_who2 - MemUsage An indication of the memory used by this process but I don’t know what it is measured in (bytes, Kb, Mb…) - IsSystem True or False depending on whether the process is internal to the SQL Server instance or has been created by an external connection requesting data. - ExecutionContextID In my experience this is always 0 so could be analogous to REQUESTID from sp_who2. Please note, these are my own very brief descriptions of these columns, detail can be found from MSDN for columns in the sp_who results here http://msdn.microsoft.com/en-GB/library/ms174313.aspx. Where the columns are common then I would use that description, in other cases then the information returned is purely for interpretation by the reader. Rather annoyingly both result sets have useful information that the other doesn’t. sp_who2 returns Disk IO and LastBatch information which is really useful but the SMO processes method give you IsSystem and MemUsage which have their place in fault diagnosis methods too. So which is better? On reflection I think I prefer to use the sp_who2 method primarily but knowing that the SMO Enumprocesses method is there when I need it is really useful and I’m sure I’ll use it regularly. I’m OK with the fact that it is the slower method because Measure-Command has shown me how close it is to the other option and that it really isn’t a large enough margin to matter.

    Read the article

  • Copy New Files Only in .NET

    - by psheriff
    Recently I had a client that had a need to copy files from one folder to another. However, there was a process that was running that would dump new files into the original folder every minute or so. So, we needed to be able to copy over all the files one time, then also be able to go back a little later and grab just the new files. After looking into the System.IO namespace, none of the classes within here met my needs exactly. Of course I could build it out of the various File and Directory classes, but then I remembered back to my old DOS days (yes, I am that old!). The XCopy command in DOS (or the command prompt for you pure Windows people) is very powerful. One of the options you can pass to this command is to grab only newer files when copying from one folder to another. So instead of writing a ton of code I decided to simply call the XCopy command using the Process class in .NET. The command I needed to run at the command prompt looked like this: XCopy C:\Original\*.* D:\Backup\*.* /q /d /y What this command does is to copy all files from the Original folder on the C drive to the Backup folder on the D drive. The /q option says to do it quitely without repeating all the file names as it copies them. The /d option says to get any newer files it finds in the Original folder that are not in the Backup folder, or any files that have a newer date/time stamp. The /y option will automatically overwrite any existing files without prompting the user to press the "Y" key to overwrite the file. To translate this into code that we can call from our .NET programs, you can write the CopyFiles method presented below. C# using System.Diagnostics public void CopyFiles(string source, string destination){  ProcessStartInfo si = new ProcessStartInfo();  string args = @"{0}\*.* {1}\*.* /q /d /y";   args = string.Format(args, source, destination);   si.FileName = "xcopy";  si.Arguments = args;  Process.Start(si);} VB.NET Imports System.Diagnostics Public Sub CopyFiles(source As String, destination As String)  Dim si As New ProcessStartInfo()  Dim args As String = "{0}\*.* {1}\*.* /q /d /y"   args = String.Format(args, source, destination)   si.FileName = "xcopy"  si.Arguments = args  Process.Start(si)End Sub The CopyFiles method first creates a ProcessStartInfo object. This object is where you fill in name of the command you wish to run and also the arguments that you wish to pass to the command. I created a string with the arguments then filled in the source and destination folders using the string.Format() method. Finally you call the Start method of the Process class passing in the ProcessStartInfo object. That's all there is to calling any command in the operating system. Very simple, and much less code than it would have taken had I coded it using the various File and Directory classes. Good Luck with your Coding,Paul Sheriff ** SPECIAL OFFER FOR MY BLOG READERS **Visit http://www.pdsa.com/Event/Blog for a free video on Silverlight entitled Silverlight XAML for the Complete Novice - Part 1.  

    Read the article

  • Why does my ping command (Windows) results alternate between "timeout" and "network is not reachable"?

    - by Sopalajo de Arrierez
    My Windows is in Spanish, so I will have to paste console outputs in that language (I think that translating without knowing the exact terms used in english versions could give worse results than leaving it as it appears on screen). This is the issue: when pinging a non-existent IP from a WinXP-SP3 machine (clean Windows install, just formatted), I get sometimes a "Timeout" result, and sometimes a "network is not reachable" message. This is the result of: ping 192.168.210.1 Haciendo ping a 192.168.210.1 con 32 bytes de datos: Tiempo de espera agotado para esta solicitud. Respuesta desde 80.58.67.86: Red de destino inaccesible. Respuesta desde 80.58.67.86: Red de destino inaccesible. Tiempo de espera agotado para esta solicitud. Estadísticas de ping para 192.168.210.1: Paquetes: enviados = 4, recibidos = 2, perdidos = 2 (50% perdidos), Tiempos aproximados de ida y vuelta en milisegundos: Mínimo = 0ms, Máximo = 0ms, Media = 0ms 192.168.210.1 does not exist on the network. DHCP client is enabled, and the computer gets assigned those network config by the router. My IP: 192.168.11.2 Netmask: 255.255.255.0 Gateway: 192.168.11.1 DNS: 80.58.0.33/194.224.52.36 This is the output from "route print command": =========================================================================== Rutas activas: Destino de red Máscara de red Puerta de acceso Interfaz Métrica 0.0.0.0 0.0.0.0 192.168.11.1 192.168.11.2 20 127.0.0.0 255.0.0.0 127.0.0.1 127.0.0.1 1 192.168.11.0 255.255.255.0 192.168.11.2 192.168.11.2 20 192.168.11.2 255.255.255.255 127.0.0.1 127.0.0.1 20 192.168.11.255 255.255.255.255 192.168.11.2 192.168.11.2 20 224.0.0.0 240.0.0.0 192.168.11.2 192.168.11.2 20 255.255.255.255 255.255.255.255 192.168.11.2 192.168.11.2 1 255.255.255.255 255.255.255.255 192.168.11.2 3 1 Puerta de enlace predeterminada: 192.168.11.1 =========================================================================== Rutas persistentes: ninguno The output of: ping 1.1.1.1 Haciendo ping a 1.1.1.1 con 32 bytes de datos: Tiempo de espera agotado para esta solicitud. Tiempo de espera agotado para esta solicitud. Tiempo de espera agotado para esta solicitud. Tiempo de espera agotado para esta solicitud. Estadísticas de ping para 1.1.1.1: Paquetes: enviados = 4, recibidos = 0, perdidos = 4 1.1.1.1 does not exist on the network. and the output of: ping 10.1.1.1 Haciendo ping a 10.1.1.1 con 32 bytes de datos: Respuesta desde 80.58.67.86: Red de destino inaccesible. Tiempo de espera agotado para esta solicitud. Tiempo de espera agotado para esta solicitud. Respuesta desde 80.58.67.86: Red de destino inaccesible. Estadísticas de ping para 10.1.1.1: Paquetes: enviados = 4, recibidos = 2, perdidos = 2 (50% perdidos), 10.1.1.1 does not exist on the network. I can do some aproximate translation of what you demand if necessary. I have another computers in the same network (WinXP-SP3 and Win7-SP1), and they have, too, this problem. Gateway (Router): Buffalo WHR-HP-GN (official Buffalo firmware, not DD-WRT). I have some Linux (Debian/Kali) machine in my network, so I tested things on it: ping 192.168.210.1 PING 192.168.210.1 (192.168.210.1) 56(84) bytes of data. From 80.58.67.86 icmp_seq=1 Packet filtered From 80.58.67.86 icmp_seq=2 Packet filtered From 80.58.67.86 icmp_seq=3 Packet filtered From 80.58.67.86 icmp_seq=4 Packet filtered to the non-existing 1.1.1.1 : ping 1.1.1.1 PING 1.1.1.1 (1.1.1.1) 56(84) bytes of data. ^C --- 1.1.1.1 ping statistics --- 153 packets transmitted, 0 received, 100% packet loss, time 153215ms (no response after waiting a few minutes). and the non-existing 10.1.1.1: ping 10.1.1.1 PING 10.1.1.1 (10.1.1.1) 56(84) bytes of data. From 80.58.67.86 icmp_seq=20 Packet filtered From 80.58.67.86 icmp_seq=22 Packet filtered From 80.58.67.86 icmp_seq=23 Packet filtered From 80.58.67.86 icmp_seq=24 Packet filtered From 80.58.67.86 icmp_seq=25 Packet filtered What is going on here? I am posing this question mainly for learning purposes, but there is another reason: when all pings are returning "timeout", it creates an %ERRORLEVEL% value of 1, but if there is someone of "Network is not reachable" type, %ERRORLEVEL% goes to 0 (no error), and this could be inappropriate for a shell script (we can not use ping to detect, for example, if the network is down due to loss of contact with the gateway).

    Read the article

  • In WPF, how do I get a command in a Control Template to bind to a property in a parent?

    - by Keith
    I am relatively new to WPF and sometimes it makes my head explode. However, I do like the power behind it, especially when used with the MVVM model. I have a control template that contains a button. I use that control template inside of a custom control. I want to add a property on the custom control that will bind to the command property of the button inside the control template. Basically, it is a combo box with a button to the right of it to allow a user to pop up a search dialog. Since this control could appear on a usercontrol multiple times, I need to be able to potentially bind each control to a different command (Searh products, search customers, etc). However, I have been unable to figure out how to do this Here is some sample XAML <Style TargetType="{x:Type m:SelectionFieldControl}"> <Setter Property="LookupTemplate" Value="{StaticResource LookupTemplate}" /> <Setter Property="Template"> <Setter.Value> <ControlTemplate TargetType="{x:Type m:SelectionFieldControl}"> <Border BorderThickness="{TemplateBinding Border.BorderThickness}" Padding="{TemplateBinding Control.Padding}" BorderBrush="{TemplateBinding Border.BorderBrush}" Background="{TemplateBinding Panel.Background}" SnapsToDevicePixels="True" Focusable="False"> <Grid> <Grid.ColumnDefinitions> <ColumnDefinition Width="Auto" MinWidth="0" SharedSizeGroup="{Binding LabelShareSizeGroupName, RelativeSource={RelativeSource FindAncestor, AncestorType={x:Type m:BaseFieldControl}}}" /> <ColumnDefinition Width="1*" /> <ColumnDefinition Width="Auto" SharedSizeGroup="{Binding WidgetsShareSizeGroupName, RelativeSource={RelativeSource FindAncestor, AncestorType={x:Type m:BaseFieldControl}}}" /> </Grid.ColumnDefinitions> <!-- Customized Value Part --> <ComboBox x:Name="PART_Value" Grid.Column="1" Margin="4,2,0,1" SelectedValue="{Binding Path=SelectionField.Value, RelativeSource={RelativeSource FindAncestor, AncestorType={x:Type m:SelectionFieldControl}}}" IsEnabled="{Binding Field.IsNotReadOnly, RelativeSource={RelativeSource FindAncestor, AncestorType={x:Type m:SelectionFieldControl}}}" Visibility="{Binding Field.IsInEditMode, Converter={StaticResource TrueToVisible}, RelativeSource={RelativeSource FindAncestor, AncestorType={x:Type m:SelectionFieldControl}}}" FontFamily="{StaticResource FontFamily_Default}" FontSize="11px"> <ComboBox.ItemsPanel> <ItemsPanelTemplate> <VirtualizingStackPanel IsVirtualizing="True" VirtualizationMode="Recycling"/> </ItemsPanelTemplate> </ComboBox.ItemsPanel> </ComboBox> <StackPanel Grid.Column="2" Orientation="Horizontal" Name="PART_Extra" Focusable="False"> <ContentControl Name="PART_LookupContent" Template="{Binding LookupTemplate, RelativeSource={RelativeSource FindAncestor, AncestorType={x:Type m:SelectionFieldControl}}}" Focusable="False"/> </StackPanel> </Grid> </Border> </ControlTemplate> </Setter.Value> </Setter> </Style> I thought I could get it to work by doing something like this <Button Command="{Binding RelativeSource={RelativeSource FindAncestor, AncestorType={x:Type SelectionFieldControl}}, Path=ShowSearchCommand}" Margin="2" /> but it does not work. Any help would be greatly appreciated.

    Read the article

  • Silverlight Commands Hacks: Passing EventArgs as CommandParameter to DelegateCommand triggered by Ev

    - by brainbox
    Today I've tried to find a way how to pass EventArgs as CommandParameter to DelegateCommand triggered by EventTrigger. By reverse engineering of default InvokeCommandAction I find that blend team just ignores event args.To resolve this issue I have created my own action for triggering delegate commands.public sealed class InvokeDelegateCommandAction : TriggerAction<DependencyObject>{    /// <summary>    ///     /// </summary>    public static readonly DependencyProperty CommandParameterProperty =        DependencyProperty.Register("CommandParameter", typeof(object), typeof(InvokeDelegateCommandAction), null);    /// <summary>    ///     /// </summary>    public static readonly DependencyProperty CommandProperty = DependencyProperty.Register(        "Command", typeof(ICommand), typeof(InvokeDelegateCommandAction), null);    /// <summary>    ///     /// </summary>    public static readonly DependencyProperty InvokeParameterProperty = DependencyProperty.Register(        "InvokeParameter", typeof(object), typeof(InvokeDelegateCommandAction), null);    private string commandName;    /// <summary>    ///     /// </summary>    public object InvokeParameter    {        get        {            return this.GetValue(InvokeParameterProperty);        }        set        {            this.SetValue(InvokeParameterProperty, value);        }    }    /// <summary>    ///     /// </summary>    public ICommand Command    {        get        {            return (ICommand)this.GetValue(CommandProperty);        }        set        {            this.SetValue(CommandProperty, value);        }    }    /// <summary>    ///     /// </summary>    public string CommandName    {        get        {            return this.commandName;        }        set        {            if (this.CommandName != value)            {                this.commandName = value;            }        }    }    /// <summary>    ///     /// </summary>    public object CommandParameter    {        get        {            return this.GetValue(CommandParameterProperty);        }        set        {            this.SetValue(CommandParameterProperty, value);        }    }    /// <summary>    ///     /// </summary>    /// <param name="parameter"></param>    protected override void Invoke(object parameter)    {        this.InvokeParameter = parameter;                if (this.AssociatedObject != null)        {            ICommand command = this.ResolveCommand();            if ((command != null) && command.CanExecute(this.CommandParameter))            {                command.Execute(this.CommandParameter);            }        }    }    private ICommand ResolveCommand()    {        ICommand command = null;        if (this.Command != null)        {            return this.Command;        }        var frameworkElement = this.AssociatedObject as FrameworkElement;        if (frameworkElement != null)        {            object dataContext = frameworkElement.DataContext;            if (dataContext != null)            {                PropertyInfo commandPropertyInfo = dataContext                    .GetType()                    .GetProperties(BindingFlags.Public | BindingFlags.Instance)                    .FirstOrDefault(                        p =>                        typeof(ICommand).IsAssignableFrom(p.PropertyType) &&                        string.Equals(p.Name, this.CommandName, StringComparison.Ordinal)                    );                if (commandPropertyInfo != null)                {                    command = (ICommand)commandPropertyInfo.GetValue(dataContext, null);                }            }        }        return command;    }}Example:<ComboBox>    <ComboBoxItem Content="Foo option 1" />    <ComboBoxItem Content="Foo option 2" />    <ComboBoxItem Content="Foo option 3" />    <Interactivity:Interaction.Triggers>        <Interactivity:EventTrigger EventName="SelectionChanged" >            <Presentation:InvokeDelegateCommandAction                 Command="{Binding SubmitFormCommand}"                CommandParameter="{Binding RelativeSource={RelativeSource Self}, Path=InvokeParameter}" />        </Interactivity:EventTrigger>    </Interactivity:Interaction.Triggers>                </ComboBox>BTW: InvokeCommanAction CommandName property are trying to find command in properties of view. It very strange, because in MVVM pattern command should be in viewmodel supplied to datacontext.

    Read the article

  • Building applications with WPF, MVVM and Prism(aka CAG)

    - by skjagini
    In this article I am going to walk through an application using WPF and Prism (aka composite application guidance, CAG) which simulates engaging a taxi (cab).  The rules are simple, the app would have3 screens A login screen to authenticate the user An information screen. A screen to engage the cab and roam around and calculating the total fare Metered Rate of Fare The meter is required to be engaged when a cab is occupied by anyone $3.00 upon entry $0.35 for each additional unit The unit fare is: one-fifth of a mile, when the cab is traveling at 6 miles an hour or more; or 60 seconds when not in motion or traveling at less than 12 miles per hour. Night surcharge of $.50 after 8:00 PM & before 6:00 AM Peak hour Weekday Surcharge of $1.00 Monday - Friday after 4:00 PM & before 8:00 PM New York State Tax Surcharge of $.50 per ride. Example: Friday (2010-10-08) 5:30pm Start at Lexington Ave & E 57th St End at Irving Pl & E 15th St Start = $3.00 Travels 2 miles at less than 6 mph for 15 minutes = $3.50 Travels at more than 12 mph for 5 minutes = $1.75 Peak hour Weekday Surcharge = $1.00 (ride started at 5:30 pm) New York State Tax Surcharge = $0.50 Before we dive into the app, I would like to give brief description about the framework.  If you want to jump on to the source code, scroll all the way to the end of the post. MVVM MVVM pattern is in no way related to the usage of PRISM in your application and should be considered if you are using WPF irrespective of PRISM or not. Lets say you are not familiar with MVVM, your typical UI would involve adding some UI controls like text boxes, a button, double clicking on the button,  generating event handler, calling a method from business layer and updating the user interface, it works most of the time for developing small scale applications. The problem with this approach is that there is some amount of code specific to business logic wrapped in UI specific code which is hard to unit test it, mock it and MVVM helps to solve the exact problem. MVVM stands for Model(M) – View(V) – ViewModel(VM),  based on the interactions with in the three parties it should be called VVMM,  MVVM sounds more like MVC (Model-View-Controller) so the name. Why it should be called VVMM: View – View Model - Model WPF allows to create user interfaces using XAML and MVVM takes it to the next level by allowing complete separation of user interface and business logic. In WPF each view will have a property, DataContext when set to an instance of a class (which happens to be your view model) provides the data the view is interested in, i.e., view interacts with view model and at the same time view model interacts with view through DataContext. Sujith, if view and view model are interacting directly with each other how does MVVM is helping me separation of concerns? Well, the catch is DataContext is of type Object, since it is of type object view doesn’t know exact type of view model allowing views and views models to be loosely coupled. View models aggregate data from models (data access layer, services, etc) and make it available for views through properties, methods etc, i.e., View Models interact with Models. PRISM Prism is provided by Microsoft Patterns and Practices team and it can be downloaded from codeplex for source code,  samples and documentation on msdn.  The name composite implies, to compose user interface from different modules (views) without direct dependencies on each other, again allowing  loosely coupled development. Well Sujith, I can already do that with user controls, why shall I learn another framework?  That’s correct, you can decouple using user controls, but you still have to manage some amount of coupling, like how to do you communicate between the controls, how do you subscribe/unsubscribe, loading/unloading views dynamically. Prism is not a replacement for user controls, provides the following features which greatly help in designing the composite applications. Dependency Injection (DI)/ Inversion of Control (IoC) Modules Regions Event Aggregator  Commands Simply put, MVVM helps building a single view and Prism helps building an application using the views There are other open source alternatives to Prism, like MVVMLight, Cinch, take a look at them as well. Lets dig into the source code.  1. Solution The solution is made of the following projects Framework: Holds the common functionality in building applications using WPF and Prism TaxiClient: Start up project, boot strapping and app styling TaxiCommon: Helps with the business logic TaxiModules: Holds the meat of the application with views and view models TaxiTests: To test the application 2. DI / IoC Dependency Injection (DI) as the name implies refers to injecting dependencies and Inversion of Control (IoC) means the calling code has no direct control on the dependencies, opposite of normal way of programming where dependencies are passed by caller, i.e inversion; aside from some differences in terminology the concept is same in both the cases. The idea behind DI/IoC pattern is to reduce the amount of direct coupling between different components of the application, the higher the dependency the more tightly coupled the application resulting in code which is hard to modify, unit test and mock.  Initializing Dependency Injection through BootStrapper TaxiClient is the starting project of the solution and App (App.xaml)  is the starting class that gets called when you run the application. From the App’s OnStartup method we will invoke BootStrapper.   namespace TaxiClient { /// <summary> /// Interaction logic for App.xaml /// </summary> public partial class App : Application { protected override void OnStartup(StartupEventArgs e) { base.OnStartup(e);   (new BootStrapper()).Run(); } } } BootStrapper is your contact point for initializing the application including dependency injection, creating Shell and other frameworks. We are going to use Unity for DI and there are lot of open source DI frameworks like Spring.Net, StructureMap etc with different feature set  and you can choose a framework based on your preferences. Note that Prism comes with in built support for Unity, for example we are deriving from UnityBootStrapper in our case and for any other DI framework you have to extend the Prism appropriately   namespace TaxiClient { public class BootStrapper: UnityBootstrapper { protected override IModuleCatalog CreateModuleCatalog() { return new ConfigurationModuleCatalog(); } protected override DependencyObject CreateShell() { Framework.FrameworkBootStrapper.Run(Container, Application.Current.Dispatcher);   Shell shell = new Shell(); shell.ResizeMode = ResizeMode.NoResize; shell.Show();   return shell; } } } Lets take a look into  FrameworkBootStrapper to check out how to register with unity container. namespace Framework { public class FrameworkBootStrapper { public static void Run(IUnityContainer container, Dispatcher dispatcher) { UIDispatcher uiDispatcher = new UIDispatcher(dispatcher); container.RegisterInstance<IDispatcherService>(uiDispatcher);   container.RegisterType<IInjectSingleViewService, InjectSingleViewService>( new ContainerControlledLifetimeManager());   . . . } } } In the above code we are registering two components with unity container. You shall observe that we are following two different approaches, RegisterInstance and RegisterType.  With RegisterInstance we are registering an existing instance and the same instance will be returned for every request made for IDispatcherService   and with RegisterType we are requesting unity container to create an instance for us when required, i.e., when I request for an instance for IInjectSingleViewService, unity will create/return an instance of InjectSingleViewService class and with RegisterType we can configure the life time of the instance being created. With ContaienrControllerLifetimeManager, the unity container caches the instance and reuses for any subsequent requests, without recreating a new instance. Lets take a look into FareViewModel.cs and it’s constructor. The constructor takes one parameter IEventAggregator and if you try to find all references in your solution for IEventAggregator, you will not find a single location where an instance of EventAggregator is passed directly to the constructor. The compiler still finds an instance and works fine because Prism is already configured when used with Unity container to return an instance of EventAggregator when requested for IEventAggregator and in this particular case it is called constructor injection. public class FareViewModel:ObservableBase, IDataErrorInfo { ... private IEventAggregator _eventAggregator;   public FareViewModel(IEventAggregator eventAggregator) { _eventAggregator = eventAggregator; InitializePropertyNames(); InitializeModel(); PropertyChanged += OnPropertyChanged; } ... 3. Shell Shells are very similar in operation to Master Pages in asp.net or MDI in Windows Forms. And shells contain regions which display the views, you can have as many regions as you wish in a given view. You can also nest regions. i.e, one region can load a view which in itself may contain other regions. We have to create a shell at the start of the application and are doing it by overriding CreateShell method from BootStrapper From the following Shell.xaml you shall notice that we have two content controls with Region names as ‘MenuRegion’ and ‘MainRegion’.  The idea here is that you can inject any user controls into the regions dynamically, i.e., a Menu User Control for MenuRegion and based on the user action you can load appropriate view into MainRegion.    <Window x:Class="TaxiClient.Shell" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:Regions="clr-namespace:Microsoft.Practices.Prism.Regions;assembly=Microsoft.Practices.Prism" Title="Taxi" Height="370" Width="800"> <Grid Margin="2"> <ContentControl Regions:RegionManager.RegionName="MenuRegion" HorizontalAlignment="Stretch" VerticalAlignment="Stretch" HorizontalContentAlignment="Stretch" VerticalContentAlignment="Stretch" />   <ContentControl Grid.Row="1" Regions:RegionManager.RegionName="MainRegion" HorizontalAlignment="Stretch" VerticalAlignment="Stretch" HorizontalContentAlignment="Stretch" VerticalContentAlignment="Stretch" /> <!--<Border Grid.ColumnSpan="2" BorderThickness="2" CornerRadius="3" BorderBrush="LightBlue" />-->   </Grid> </Window> 4. Modules Prism provides the ability to build composite applications and modules play an important role in it. For example if you are building a Mortgage Loan Processor application with 3 components, i.e. customer’s credit history,  existing mortgages, new home/loan information; and consider that the customer’s credit history component involves gathering data about his/her address, background information, job details etc. The idea here using Prism modules is to separate the implementation of these 3 components into their own visual studio projects allowing to build components with no dependency on each other and independently. If we need to add another component to the application, the component can be developed by in house team or some other team in the organization by starting with a new Visual Studio project and adding to the solution at the run time with very little knowledge about the application. Prism modules are defined by implementing the IModule interface and each visual studio project to be considered as a module should implement the IModule interface.  From the BootStrapper.cs you shall observe that we are overriding the method by returning a ConfiguratingModuleCatalog which returns the modules that are registered for the application using the app.config file  and you can also add module using code. Lets take a look into configuration file.   <?xml version="1.0"?> <configuration> <configSections> <section name="modules" type="Microsoft.Practices.Prism.Modularity.ModulesConfigurationSection, Microsoft.Practices.Prism"/> </configSections> <modules> <module assemblyFile="TaxiModules.dll" moduleType="TaxiModules.ModuleInitializer, TaxiModules" moduleName="TaxiModules"/> </modules> </configuration> Here we are adding TaxiModules project to our solution and TaxiModules.ModuleInitializer implements IModule interface   5. Module Mapper With Prism modules you can dynamically add or remove modules from the regions, apart from that Prism also provides API to control adding/removing the views from a region within the same module. Taxi Information Screen: Engage the Taxi Screen: The sample application has two screens, ‘Taxi Information’ and ‘Engage the Taxi’ and they both reside in same module, TaxiModules. ‘Engage the Taxi’ is again made of two user controls, FareView on the left and TotalView on the right. We have created a Shell with two regions, MenuRegion and MainRegion with menu loaded into MenuRegion. We can create a wrapper user control called EngageTheTaxi made of FareView and TotalView and load either TaxiInfo or EngageTheTaxi into MainRegion based on the user action. Though it will work it tightly binds the user controls and for every combination of user controls, we need to create a dummy wrapper control to contain them. Instead we can apply the principles we learned so far from Shell/regions and introduce another template (LeftAndRightRegionView.xaml) made of two regions Region1 (left) and Region2 (right) and load  FareView and TotalView dynamically.  To help with loading of the views dynamically I have introduce an helper an interface, IInjectSingleViewService,  idea suggested by Mike Taulty, a must read blog for .Net developers. using System; using System.Collections.Generic; using System.ComponentModel;   namespace Framework.PresentationUtility.Navigation {   public interface IInjectSingleViewService : INotifyPropertyChanged { IEnumerable<CommandViewDefinition> Commands { get; } IEnumerable<ModuleViewDefinition> Modules { get; }   void RegisterViewForRegion(string commandName, string viewName, string regionName, Type viewType); void ClearViewFromRegion(string viewName, string regionName); void RegisterModule(string moduleName, IList<ModuleMapper> moduleMappers); } } The Interface declares three methods to work with views: RegisterViewForRegion: Registers a view with a particular region. You can register multiple views and their regions under one command.  When this particular command is invoked all the views registered under it will be loaded into their regions. ClearViewFromRegion: To unload a specific view from a region. RegisterModule: The idea is when a command is invoked you can load the UI with set of controls in their default position and based on the user interaction, you can load different contols in to different regions on the fly.  And it is supported ModuleViewDefinition and ModuleMappers as shown below. namespace Framework.PresentationUtility.Navigation { public class ModuleViewDefinition { public string ModuleName { get; set; } public IList<ModuleMapper> ModuleMappers; public ICommand Command { get; set; } }   public class ModuleMapper { public string ViewName { get; set; } public string RegionName { get; set; } public Type ViewType { get; set; } } } 6. Event Aggregator Prism event aggregator enables messaging between components as in Observable pattern, Notifier notifies the Observer which receives notification it is interested in. When it comes to Observable pattern, Observer has to unsubscribes for notifications when it no longer interested in notifications, which allows the Notifier to remove the Observer’s reference from it’s local cache. Though .Net has managed garbage collection it cannot remove inactive the instances referenced by an active instance resulting in memory leak, keeping the Observers in memory as long as Notifier stays in memory.  Developers have to be very careful to unsubscribe when necessary and it often gets overlooked, to overcome these problems Prism Event Aggregator uses weak references to cache the reference (Observer in this case)  and releases the reference (memory) once the instance goes out of scope. Using event aggregator is very simple, declare a generic type of CompositePresenationEvent by inheriting from it. using Microsoft.Practices.Prism.Events; using TaxiCommon.BAO;   namespace TaxiCommon.CompositeEvents { public class TaxiOnMoveEvent:CompositePresentationEvent<TaxiOnMove> { } }   TaxiOnMove.cs includes the properties which we want to exchange between the parties, FareView and TotalView. using System;   namespace TaxiCommon.BAO { public class TaxiOnMove { public TimeSpan MinutesAtTweleveMPH { get; set; } public double MilesAtSixMPH { get; set; } } }   Lets take a look into FareViewodel (Notifier) and how it raises the event.  Here we are raising the event by getting the event through GetEvent<..>() and publishing it with the payload private void OnAddMinutes(object obj) { TaxiOnMove payload = new TaxiOnMove(); if(MilesAtSixMPH != null) payload.MilesAtSixMPH = MilesAtSixMPH.Value; if(MinutesAtTweleveMPH != null) payload.MinutesAtTweleveMPH = new TimeSpan(0,0,MinutesAtTweleveMPH.Value,0);   _eventAggregator.GetEvent<TaxiOnMoveEvent>().Publish(payload); ResetMinutesAndMiles(); } And TotalViewModel(Observer) subscribes to notifications by getting the event through GetEvent<..>() namespace TaxiModules.ViewModels { public class TotalViewModel:ObservableBase { .... private IEventAggregator _eventAggregator;   public TotalViewModel(IEventAggregator eventAggregator) { _eventAggregator = eventAggregator; ... }   private void SubscribeToEvents() { _eventAggregator.GetEvent<TaxiStartedEvent>() .Subscribe(OnTaxiStarted, ThreadOption.UIThread,false,(filter) => true); _eventAggregator.GetEvent<TaxiOnMoveEvent>() .Subscribe(OnTaxiMove, ThreadOption.UIThread, false, (filter) => true); _eventAggregator.GetEvent<TaxiResetEvent>() .Subscribe(OnTaxiReset, ThreadOption.UIThread, false, (filter) => true); }   ... private void OnTaxiMove(TaxiOnMove taxiOnMove) { OnMoveFare fare = new OnMoveFare(taxiOnMove); Fares.Add(fare); SetTotalFare(new []{fare}); }   .... 7. MVVM through example In this section we are going to look into MVVM implementation through example.  I have all the modules declared in a single project, TaxiModules, again it is not necessary to have them into one project. Once the user logs into the application, will be greeted with the ‘Engage the Taxi’ screen which is made of two user controls, FareView.xaml and TotalView.Xaml. As you can see from the solution explorer, each of them have their own code behind files and  ViewModel classes, FareViewMode.cs, TotalViewModel.cs Lets take a look in to the FareView and how it interacts with FareViewModel using MVVM implementation. FareView.xaml acts as a view and FareViewMode.cs is it’s view model. The FareView code behind class   namespace TaxiModules.Views { /// <summary> /// Interaction logic for FareView.xaml /// </summary> public partial class FareView : UserControl { public FareView(FareViewModel viewModel) { InitializeComponent(); this.Loaded += (s, e) => { this.DataContext = viewModel; }; } } } The FareView is bound to FareViewModel through the data context  and you shall observe that DataContext is of type Object, i.e. the FareView doesn’t really know the type of ViewModel (FareViewModel). This helps separation of View and ViewModel as View and ViewModel are independent of each other, you can bind FareView to FareViewModel2 as well and the application compiles just fine. Lets take a look into FareView xaml file  <UserControl x:Class="TaxiModules.Views.FareView" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:Toolkit="clr-namespace:Microsoft.Windows.Controls;assembly=WPFToolkit" xmlns:Commands="clr-namespace:Microsoft.Practices.Prism.Commands;assembly=Microsoft.Practices.Prism"> <Grid Margin="10" > ....   <Border Style="{DynamicResource innerBorder}" Grid.Row="0" Grid.Column="0" Grid.RowSpan="11" Grid.ColumnSpan="2" Panel.ZIndex="1"/>   <Label Grid.Row="0" Content="Engage the Taxi" Style="{DynamicResource innerHeader}"/> <Label Grid.Row="1" Content="Select the State"/> <ComboBox Grid.Row="1" Grid.Column="1" ItemsSource="{Binding States}" Height="auto"> <ComboBox.ItemTemplate> <DataTemplate> <TextBlock Text="{Binding Name}"/> </DataTemplate> </ComboBox.ItemTemplate> <ComboBox.SelectedItem> <Binding Path="SelectedState" Mode="TwoWay"/> </ComboBox.SelectedItem> </ComboBox> <Label Grid.Row="2" Content="Select the Date of Entry"/> <Toolkit:DatePicker Grid.Row="2" Grid.Column="1" SelectedDate="{Binding DateOfEntry, ValidatesOnDataErrors=true}" /> <Label Grid.Row="3" Content="Enter time 24hr format"/> <TextBox Grid.Row="3" Grid.Column="1" Text="{Binding TimeOfEntry, TargetNullValue=''}"/> <Button Grid.Row="4" Grid.Column="1" Content="Start the Meter" Commands:Click.Command="{Binding StartMeterCommand}" />   <Label Grid.Row="5" Content="Run the Taxi" Style="{DynamicResource innerHeader}"/> <Label Grid.Row="6" Content="Number of Miles &lt;@6mph"/> <TextBox Grid.Row="6" Grid.Column="1" Text="{Binding MilesAtSixMPH, TargetNullValue='', ValidatesOnDataErrors=true}"/> <Label Grid.Row="7" Content="Number of Minutes @12mph"/> <TextBox Grid.Row="7" Grid.Column="1" Text="{Binding MinutesAtTweleveMPH, TargetNullValue=''}"/> <Button Grid.Row="8" Grid.Column="1" Content="Add Minutes and Miles " Commands:Click.Command="{Binding AddMinutesCommand}"/> <Label Grid.Row="9" Content="Other Operations" Style="{DynamicResource innerHeader}"/> <Button Grid.Row="10" Grid.Column="1" Content="Reset the Meter" Commands:Click.Command="{Binding ResetCommand}"/>   </Grid> </UserControl> The highlighted code from the above code shows data binding, for example ComboBox which displays list of states has it’s ItemsSource bound to States property, with DataTemplate bound to Name and SelectedItem  to SelectedState. You might be wondering what are all these properties and how it is able to bind to them.  The answer lies in data context, i.e., when you bound a control, WPF looks for data context on the root object (Grid in this case) and if it can’t find data context it will look into root’s root, i.e. FareView UserControl and it is bound to FareViewModel.  Each of those properties have be declared on the ViewModel for the View to bind correctly. To put simply, View is bound to ViewModel through data context of type object and every control that is bound on the View actually binds to the public property on the ViewModel. Lets look into the ViewModel code (the following code is not an exact copy of FareViewMode.cs, pasted relevant code for this section)   namespace TaxiModules.ViewModels { public class FareViewModel:ObservableBase, IDataErrorInfo { public List<USState> States { get { return USStates.StateList; } }   public USState SelectedState { get { return _selectedState; } set { _selectedState = value; RaisePropertyChanged(_selectedStatePropertyName); } }   public DateTime? DateOfEntry { get { return _dateOfEntry; } set { _dateOfEntry = value; RaisePropertyChanged(_dateOfEntryPropertyName); } }   public TimeSpan? TimeOfEntry { get { return _timeOfEntry; } set { _timeOfEntry = value; RaisePropertyChanged(_timeOfEntryPropertyName); } }   public double? MilesAtSixMPH { get { return _milesAtSixMPH; } set { _milesAtSixMPH = value; RaisePropertyChanged(_distanceAtSixMPHPropertyName); } }   public int? MinutesAtTweleveMPH { get { return _minutesAtTweleveMPH; } set { _minutesAtTweleveMPH = value; RaisePropertyChanged(_minutesAtTweleveMPHPropertyName); } }   public ICommand StartMeterCommand { get { if(_startMeterCommand == null) { _startMeterCommand = new DelegateCommand<object>(OnStartMeter, CanStartMeter); } return _startMeterCommand; } }   public ICommand AddMinutesCommand { get { if(_addMinutesCommand == null) { _addMinutesCommand = new DelegateCommand<object>(OnAddMinutes, CanAddMinutes); } return _addMinutesCommand; } }   public ICommand ResetCommand { get { if(_resetCommand == null) { _resetCommand = new DelegateCommand<object>(OnResetCommand); } return _resetCommand; } }   } private void OnStartMeter(object obj) { _eventAggregator.GetEvent<TaxiStartedEvent>().Publish( new TaxiStarted() { EngagedOn = DateOfEntry.Value.Date + TimeOfEntry.Value, EngagedState = SelectedState.Value });   _isMeterStarted = true; OnPropertyChanged(this,null); } And views communicate user actions like button clicks, tree view item selections, etc using commands. When user clicks on ‘Start the Meter’ button it invokes the method StartMeterCommand, which calls the method OnStartMeter which publishes the event to TotalViewModel using event aggregator  and TaxiStartedEvent. namespace TaxiModules.ViewModels { public class TotalViewModel:ObservableBase { ... private IEventAggregator _eventAggregator;   public TotalViewModel(IEventAggregator eventAggregator) { _eventAggregator = eventAggregator;   InitializePropertyNames(); InitializeModel(); SubscribeToEvents(); }   public decimal? TotalFare { get { return _totalFare; } set { _totalFare = value; RaisePropertyChanged(_totalFarePropertyName); } } .... private void SubscribeToEvents() { _eventAggregator.GetEvent<TaxiStartedEvent>().Subscribe(OnTaxiStarted, ThreadOption.UIThread,false,(filter) => true); _eventAggregator.GetEvent<TaxiOnMoveEvent>().Subscribe(OnTaxiMove, ThreadOption.UIThread, false, (filter) => true); _eventAggregator.GetEvent<TaxiResetEvent>().Subscribe(OnTaxiReset, ThreadOption.UIThread, false, (filter) => true); }   private void OnTaxiStarted(TaxiStarted taxiStarted) { Fares.Add(new EntryFare()); Fares.Add(new StateTaxFare(taxiStarted)); Fares.Add(new NightSurchargeFare(taxiStarted)); Fares.Add(new PeakHourWeekdayFare(taxiStarted));   SetTotalFare(Fares); }   private void SetTotalFare(IEnumerable<IFare> fares) { TotalFare = (_totalFare ?? 0) + TaxiFareHelper.GetTotalFare(fares); } ....   } }   TotalViewModel subscribes to events, TaxiStartedEvent and rest. When TaxiStartedEvent gets invoked it calls the OnTaxiStarted method which sets the total fare which includes entry fee, state tax, nightly surcharge, peak hour weekday fare.   Note that TotalViewModel derives from ObservableBase which implements the method RaisePropertyChanged which we are invoking in Set of TotalFare property, i.e, once we update the TotalFare property it raises an the event that  allows the TotalFare text box to fetch the new value through the data context. ViewModel is communicating with View through data context and it has no knowledge about View, helping in loose coupling of ViewModel and View.   I have attached the source code (.Net 4.0, Prism 4.0, VS 2010) , download and play with it and don’t forget to leave your comments.  

    Read the article

  • Installing UCMA 3.0 and Creating a Communications Server "14"Trusted Application Pool

    A lot of setup and administration tasks have gotten a lot easier in Communications Server 14; one of them is building an application server to develop and run your UCMA 3.0 applications on. In this post, Ill walk you through installing the UCMA 3.0 Core SDK and creating a Trusted Application Pool on the server, thus adding it to the Communications Server 14 topology and allowing you to host and run UCMA 3.0 applications on it. Note: These instructions will change slightly as the bits get updated for the eventual Beta release I will update this post as soon as I get a chance to run this setup on a more recent build. Im doing the install on a simple Communications Server 14 topology consisting of the following Windows Server 2008 R2 Hyper-V images: DC Domain Controller ExchangeUM Exchange Server 2010 CS-SE Microsoft Communications Server 2010 Standard Edition TS Development machine Ill walk through setting up UCMA 3.0 on the TS VM, which is a fully patched Windows Server 2008 R2 machine that is joined to the Fabrikam domain.   Im also running Visual Studio 2010 on this VM because I intend to use it as a development machine.  In a future post, Ill walk through installing just the UCMA 3.0 run time to build a true production UCMA application server. Im making a couple of assumptions here: You have an existing CS 2010 site and cluster configured(well look at this in a future post) Youre starting with a fully patched Windows Server 2008 R2 machine The machine is joined to your domain This walkthrough was done in my Fabrikam VM environment but can easily be modified for your own environment. Installing the UCMA 3.0 SDK Lets start by installing the UCMA 3.0 SDK.  Run UcmaSdkWebDownload.msi to kick off the SDK installer package extract process. The installed package is extracted to C: >> Program Files >> Microsoft UCMA 3.0 >> SDK Installer Package.  Browse there and run setup.exe. Click Install to install the UCMA 3.0 Core SDK and Workflow SDK. Install Communications Server Core Components UCMA 3.0 introduces a new concept called Auto-provisioning, which is most easily explained from the developer point of view.  Remember what your app.config looked it in UCMA 2.0?  You had to store the application GRUU, the trusted contact SIP Uri, the port for your application, and the name of the certificate authority. Thats all gone with auto-provisioning all you need in your app.config is your ApplicationId, e.g.: urn:application:MyApplication. How does CS 2010 do this? All of the applications configuration data is associated with the applications id.  UCMA also queries a replicated copy of the Central Management Database to retrieve the applications configuration data and also the configuration data for any endpoints. In this step, well run Bootstrapper.exe to install the CS Core components, this checked for the following components and installs them if they are not already present: VcRedist Sqlexpress Sqlnativeclient Sqlbackcompat Ucmaredist OcsCore.msi Open a command window at C: >> Program Files >> Microsoft Communications Server 2010 >> Deployment and run the following command: Bootstrapper.exe /BootstrapReplica /MinCache /SourceDirectory:"%ProgramFiles%\Microsoft UCMA 3.0\SDK Installer Package\Prereq\BootstrapperCache" Create a New Trusted Application Pool The next step is to create a new trusted application pool for the new server.  Fire up the Communications Server Management Shell from Start >> Microsoft Communications Server 2010 >> Communications Server Management Shell and enter the following PowerShell command: New-CsTrustedApplicationPool -Identity <FQDN of Server> -Registrar <FQDN of CS Server> -Site <CS Site Name> Verify that the new server was added to the CS topology by running the following PowerShell command: (Get-CsTopology -AsXml).ToString() > Topology.xml This created a file called Topology.xml in the directory that you ran the command from.  Open the file and find the Clusters section and look for a node for the new server. The Cluster Fqdn is the name of your server, and note the name of the Site that this Cluster is a part of. <Cluster Fqdn="appsrv.fabrikam.com" RequiresReplication="true" RequiresSetup="true"> <ClusterId SiteId="UcMarketing2" Number="5" /> <Machine OrdinalInCluster="1" Fqdn="appsrv.fabrikam.com"> <NetInterface InterfaceSide="Primary" InterfaceNumber="1" IPAddress="0.0.0.0" /> </Machine> </Cluster> Configure CS Management Store Replication At this point, we have the CS Core components installed and the server configured as a trusted application pool.  We now need to set up replication so that the Central Management Store replicates down to the new server. From the Communications Server Management Shell, run the following PowerShell command to enable the Replica service on the new server: Enable-CSReplica The Replica service is enabled, but hasn't done anything yet. This can be verified by running the following PowerShell command to check the replication status for the various servers in the topology: Get-CSManagementStoreReplicationStatus You can see in the screenshot below that the UpToDate property of the new server is still False Run the following PowerShell command to force the replication to run: Invoke-CSManagementStoreReplicationStatus Run Get-CSManagementStoreReplicationStatus again to verify that the new service is now up to date Request and Set a New Certificate The last step in the process is to request a new certificate from the certificate authority on the domain and assign it to the new server. From the Communications Server Management Shell, run the following PowerShell command to request a new certificate: Request-CSCertificate -Action new -Type default -CA <Domain Controller FQDN>\<Certificate Authority> Setting the -Verbose switch on the cmdlet creates an Xml file with its output. Open the Xml file and copy the thumbprint of the generated certificate. <?xml version="1.0" encoding="utf-8"?> <Action Name="Request-CsCertificate" Time="20100512T212258"> <Action Name="Request-CsCertificate" Time="20100512T212258"> <Info Title="Connection" Time="20100512T212258">Data Source=(local)\rtclocal;Initial Catalog=xds;Integrated Security=True</Info> <Action Time="20100512T212258"> <Info Title="Certificate use" Time="20100512T212258">urn:certref:default</Info> <Info Title="Subject distinguished name" Time="20100512T212258">CN="appsrv2.fabrikam.com"</Info> <Info Time="20100512T212259">The certificate request is submitted to the Certification Authority dc.fabrikam.com\FabrikamCA.</Info> <Info Time="20100512T212259">The certificate was issued.</Info> <Info Time="20100512T212259">The certificate was imported with thumbprint AFC3C46E459C1A39AD06247676F3555826DBF705.</Info> <Complete Time="20100512T212259" /> </Action> <Info Title="command status" Time="20100512T212259">Command execution processing completed</Info> <Action Name="DeploymentXdsCmdlet.SaveCachedItems" Time="20100512T212259"> <Info Time="20100512T212259">0 updates</Info> <Complete Time="20100512T212259" /> </Action> <Info Title="command status" Time="20100512T212259">Command has completed</Info> </Action> </Action> Run the following PowerShell command to set the certificate: Set-CsCertificate -Type Default -Thumbprint <Thumbprint> Wrapping Up You now have a new UCMA 3.0 application server in your Communications Server 2010 server topology.  You can provision trusted applications and trusted application endpoints on the new server using the Communications Server 2010 Management Shell.  Well take a look at how to do that in another post. Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • How to get MSBuild Exec to run a java program?

    - by Vaccano
    I am trying to run a command line action in my Team Build (MSBuild). When I run it on the command line of the build machine it works fine. But when run in the build script I get a "exited with code 3". This is command that I am running: C:\Program Files\Wavelink\Avalanche\PackageBuilder.\jresdk\bin\java -classpath "WLUtil.jar;WLPackageBuilder.jar" com.wavelink.buildpkg.AvalanchePackageBuilder /build PackageName This command only works when run from the above directory (I have tried running it from c:\ with the full path at it fails). When I try to run it using ms build this is my statement: <PropertyGroup> <!--Working directory of the Package Builder Call--> <PkgBldWorkingDir>&quot;C:\Program Files\Wavelink\Avalanche\PackageBuilder&quot;</PkgBldWorkingDir> <!--Command line to run to make Package builder "go"--> <PkgBldRun>.\jresdk\bin\java&quot; -classpath &quot;WLUtil.jar;WLPackageBuilder.jar&quot; com.wavelink.buildpkg.AvalanchePackageBuilder</PkgBldRun> </PropertyGroup> <!--Run package builder command line to update the Ava File.--> <Exec ContinueOnError="true" WorkingDirectory="$(PackageBuilderWorkingDir)" Command="$(PkgBldRun) /build PackageName"/> As I said above this "exits with code 3". This is the full output: Task "Exec" Command: .\jresdk\bin\java -classpath "WLUtil.jar;WLPackageBuilder.jar" com.wavelink.buildpkg.AvalanchePackageBuilder /build PackageName The system cannot find the path specified. MSBUILD : warning MSB3073: The command ".\jresdk\bin\java -classpath "WLUtil.jar;WLPackageBuilder.jar" com.wavelink.buildpkg.AvalanchePackageBuilder /build PackageName" exited with code 3. The previous error was converted to a warning because the task was called with ContinueOnError=true. Build continuing because "ContinueOnError" on the task "Exec" is set to "true". Done executing task "Exec" -- FAILED. It says it can't find the file (who knows what file). I have tried it with and without the quotes (") in the working directory and with a full path as the command (gives the same error as when run on the command line). Any ideas on how to make this run a command line action in MS Build?

    Read the article

  • Run powershell commands in C#

    - by Ramnik
    RunspaceConfiguration psConfig = RunspaceConfiguration.Create(); Runspace psRunspace = RunspaceFactory.CreateRunspace(psConfig); psRunspace.Open(); using (Pipeline psPipeline = psRunspace.CreatePipeline()) { // Define the command to be executed in this pipeline Command command = new Command("Add-spsolution"); // Add a parameter to this command command.Parameters.Add("literalpath", @"c:\project3.wsp"); // Add this command to the pipeline psPipeline.Commands.Add(command); // Invoke the cmdlet try { Collection<PSObject> results = psPipeline.Invoke(); Label1.Text = "hi"+results.ToString(); // Process the results } catch (Exception exception) { Label1.Text = exception.ToString();// Process the exception here } } It is throwing the exception: System.Management.Automation.CommandNotFoundException: The term 'add-spsolution' is not recognized as the name of a cmdlet, function, script file, or operable program. Any suggestions why?

    Read the article

  • [WPF] How to register to/listen to richtextbox command's?

    - by Liewe
    I'm creating a simple editor within our application using the WPF RichTextBox. Above it I've added the reguslar buttons like Bold, Italic, etc. These buttons use the RichTextBox's commands to set these properties, but next to these buttons, the commands also get send with CTRL+B, CTRL+I, etc. I want these buttons to represent the current state of the RichTextBox at the cursor. I already found out how to get this state and it works when I update this state on the SelectionChanged event. This event ofcourse isn't fired when Bold is toggled so there is no direct feedback. I would like to know if there is a way to listen to the commands being called, without affecting its original behaviour or some other ideas to solve my problems. I tried listening to the command the following way: CommandBinding boldBinding = new CommandBinding(EditingCommands.ToggleBold, CommandExecuted); _richTextBox.CommandBindings.Add(boldBinding); and private void CommandExecuted(object sender, ExecutedRoutedEventArgs e) { UpdateProperties(); e.Handled = false; } This did update the properties, but the RichTextBox didn't seem to receive the command anymore. I also tried to make my own commands on the control containing the RichTextBox, but when CTRL+B is pressed when the RichTextBox has focus, the original RichTextBox commands are called instead of the new one. Many thanks in advance! Liewe

    Read the article

  • grep is inconsistently defaulting to grep -P?

    - by Sammitch
    I have a script that does some housekeeping that works perfectly well when invoked from an interactive shell, but did nothing when invoked by cron. To troubleshoot this I started a shell with a 'blank' environment with the command: env -i /bin/bash --noprofile --norc Using this blank env I've dug into my script and found that the following grep will not match any files: grep -il "^ws_status\s*=\s*[\"']remove[\"']$" However, when run from an interactive shell the command will return the filenames of the matching files. As a note, the expression is matching lines like: WS_STATUS = "remove" Through trial-and-error I discovered that adding -P to the options [Perl regex] the command started working normally in the 'blank' shell. However, I have no idea why my login shell appears to be defaulted to grep -P. There is only one grep binary, /bin/grep There are no aliases defined for grep=pgrep or grep="grep -P" There is no env variable GREP_OPTIONS defined. What's the deal here? Note: OS is RHEL v5.10, Bash is v3.2.25, grep is v2.5.1

    Read the article

  • Error when trying to compile abgx360: C++ compiler cannot create executables

    - by era878
    I am trying to compile the abgx360 GUI. First I run home/eric/Desktop/abgx360-1.0.5/configure but I recieve this error: checking for C++ compiler default output file name... configure: error: C++ compiler cannot create executables See `config.log' for more details. Then i run make but I recieve this error: make: * No rule to make target `/home/eric/Desktop/abgx360-1.0.5/Makefile.am', needed by `/home/eric/Desktop/abgx360-1.0.5/Makefile.in'. Stop. Here is my 'config.log': This file contains any messages produced by compilers while running configure, to aid debugging if configure makes a mistake. It was created by abgx360gui configure 1.0.2, which was generated by GNU Autoconf 2.61. Invocation command line was $ /home/eric/Desktop/abgx360gui-1.0.2/configure ## --------- ## ## Platform. ## ## --------- ## hostname = Eric-Desktop uname -m = x86_64 uname -r = 2.6.35-27-generic uname -s = Linux uname -v = #48-Ubuntu SMP Tue Feb 22 20:25:46 UTC 2011 /usr/bin/uname -p = unknown /bin/uname -X = unknown /bin/arch = unknown /usr/bin/arch -k = unknown /usr/convex/getsysinfo = unknown /usr/bin/hostinfo = unknown /bin/machine = unknown /usr/bin/oslevel = unknown /bin/universe = unknown PATH: /usr/local/sbin PATH: /usr/local/bin PATH: /usr/sbin PATH: /usr/bin PATH: /sbin PATH: /bin PATH: /usr/games ## ----------- ## ## Core tests. ## ## ----------- ## configure:1800: checking for a BSD-compatible install configure:1856: result: /usr/bin/install -c configure:1867: checking whether build environment is sane configure:1910: result: yes configure:1938: checking for a thread-safe mkdir -p configure:1977: result: /bin/mkdir -p configure:1990: checking for gawk configure:2020: result: no configure:1990: checking for mawk configure:2006: found /usr/bin/mawk configure:2017: result: mawk configure:2028: checking whether make sets $(MAKE) configure:2049: result: yes configure:2302: checking for g++ configure:2332: result: no configure:2302: checking for c++ configure:2332: result: no configure:2302: checking for gpp configure:2332: result: no configure:2302: checking for aCC configure:2332: result: no configure:2302: checking for CC configure:2332: result: no configure:2302: checking for cxx configure:2332: result: no configure:2302: checking for cc++ configure:2332: result: no configure:2302: checking for cl.exe configure:2332: result: no configure:2302: checking for FCC configure:2332: result: no configure:2302: checking for KCC configure:2332: result: no configure:2302: checking for RCC configure:2332: result: no configure:2302: checking for xlC_r configure:2332: result: no configure:2302: checking for xlC configure:2332: result: no configure:2360: checking for C++ compiler version configure:2367: g++ --version >&5 /home/eric/Desktop/abgx360gui-1.0.2/configure: line 2368: g++: command not found configure:2370: $? = 127 configure:2377: g++ -v >&5 /home/eric/Desktop/abgx360gui-1.0.2/configure: line 2378: g++: command not found configure:2380: $? = 127 configure:2387: g++ -V >&5 /home/eric/Desktop/abgx360gui-1.0.2/configure: line 2388: g++: command not found configure:2390: $? = 127 configure:2413: checking for C++ compiler default output file name configure:2440: g++ conftest.cpp >&5 /home/eric/Desktop/abgx360gui-1.0.2/configure: line 2441: g++: command not found configure:2443: $? = 127 configure:2481: result: configure: failed program was: | /* confdefs.h. */ | #define PACKAGE_NAME "abgx360gui" | #define PACKAGE_TARNAME "abgx360gui" | #define PACKAGE_VERSION "1.0.2" | #define PACKAGE_STRING "abgx360gui 1.0.2" | #define PACKAGE_BUGREPORT "" | #define PACKAGE "abgx360gui" | #define VERSION "1.0.2" | /* end confdefs.h. */ | | int | main () | { | | ; | return 0; | } configure:2488: error: C++ compiler cannot create executables See `config.log' for more details. ## ---------------- ## ## Cache variables. ## ## ---------------- ## ac_cv_env_CCC_set= ac_cv_env_CCC_value= ac_cv_env_CC_set= ac_cv_env_CC_value= ac_cv_env_CFLAGS_set= ac_cv_env_CFLAGS_value= ac_cv_env_CPPFLAGS_set= ac_cv_env_CPPFLAGS_value= ac_cv_env_CPP_set= ac_cv_env_CPP_value= ac_cv_env_CXXFLAGS_set= ac_cv_env_CXXFLAGS_value= ac_cv_env_CXX_set= ac_cv_env_CXX_value= ac_cv_env_LDFLAGS_set= ac_cv_env_LDFLAGS_value= ac_cv_env_LIBS_set= ac_cv_env_LIBS_value= ac_cv_env_build_alias_set= ac_cv_env_build_alias_value= ac_cv_env_host_alias_set= ac_cv_env_host_alias_value= ac_cv_env_target_alias_set= ac_cv_env_target_alias_value= ac_cv_path_install='/usr/bin/install -c' ac_cv_path_mkdir=/bin/mkdir ac_cv_prog_AWK=mawk ac_cv_prog_make_make_set=yes ## ----------------- ## ## Output variables. ## ## ----------------- ## ACLOCAL='${SHELL} /home/eric/Desktop/abgx360gui-1.0.2/missing --run aclocal-1.10' AMDEPBACKSLASH='' AMDEP_FALSE='' AMDEP_TRUE='' AMTAR='${SHELL} /home/eric/Desktop/abgx360gui-1.0.2/missing --run tar' AUTOCONF='${SHELL} /home/eric/Desktop/abgx360gui-1.0.2/missing --run autoconf' AUTOHEADER='${SHELL} /home/eric/Desktop/abgx360gui-1.0.2/missing --run autoheader' AUTOMAKE='${SHELL} /home/eric/Desktop/abgx360gui-1.0.2/missing --run automake-1.10' AWK='mawk' CC='' CCDEPMODE='' CFLAGS='' CPP='' CPPFLAGS='' CXX='g++' CXXDEPMODE='' CXXFLAGS='' CYGPATH_W='echo' DEFS='' DEPDIR='' ECHO_C='' ECHO_N='-n' ECHO_T='' EGREP='' EXEEXT='' GREP='' INSTALL_DATA='${INSTALL} -m 644' INSTALL_PROGRAM='${INSTALL}' INSTALL_SCRIPT='${INSTALL}' INSTALL_STRIP_PROGRAM='$(install_sh) -c -s' LDFLAGS='' LIBOBJS='' LIBS='' LTLIBOBJS='' MAKEINFO='${SHELL} /home/eric/Desktop/abgx360gui-1.0.2/missing --run makeinfo' OBJEXT='' PACKAGE='abgx360gui' PACKAGE_BUGREPORT='' PACKAGE_NAME='abgx360gui' PACKAGE_STRING='abgx360gui 1.0.2' PACKAGE_TARNAME='abgx360gui' PACKAGE_VERSION='1.0.2' PATH_SEPARATOR=':' SET_MAKE='' SHELL='/bin/bash' STRIP='' VERSION='1.0.2' WX_CFLAGS='' WX_CFLAGS_ONLY='' WX_CONFIG_PATH='' WX_CPPFLAGS='' WX_CXXFLAGS='' WX_CXXFLAGS_ONLY='' WX_LIBS='' WX_LIBS_STATIC='' WX_RESCOMP='' WX_VERSION='' ac_ct_CC='' ac_ct_CXX='' am__fastdepCC_FALSE='' am__fastdepCC_TRUE='' am__fastdepCXX_FALSE='' am__fastdepCXX_TRUE='' am__include='' am__isrc=' -I$(srcdir)' am__leading_dot='.' am__quote='' am__tar='${AMTAR} chof - "$$tardir"' am__untar='${AMTAR} xf -' bindir='${exec_prefix}/bin' build_alias='' datadir='${datarootdir}' datarootdir='${prefix}/share' docdir='${datarootdir}/doc/${PACKAGE_TARNAME}' dvidir='${docdir}' exec_prefix='NONE' host_alias='' htmldir='${docdir}' includedir='${prefix}/include' infodir='${datarootdir}/info' install_sh='$(SHELL) /home/eric/Desktop/abgx360gui-1.0.2/install-sh' libdir='${exec_prefix}/lib' libexecdir='${exec_prefix}/libexec' localedir='${datarootdir}/locale' localstatedir='${prefix}/var' mandir='${datarootdir}/man' mkdir_p='/bin/mkdir -p' oldincludedir='/usr/include' pdfdir='${docdir}' prefix='NONE' program_transform_name='s,x,x,' psdir='${docdir}' sbindir='${exec_prefix}/sbin' sharedstatedir='${prefix}/com' sysconfdir='${prefix}/etc' target_alias='' ## ----------- ## ## confdefs.h. ## ## ----------- ## #define PACKAGE_NAME "abgx360gui" #define PACKAGE_TARNAME "abgx360gui" #define PACKAGE_VERSION "1.0.2" #define PACKAGE_STRING "abgx360gui 1.0.2" #define PACKAGE_BUGREPORT "" #define PACKAGE "abgx360gui" #define VERSION "1.0.2" configure: exit 77

    Read the article

  • Why does a user have to enter "Profile" data to enter data into other tables?

    - by Greg McNulty
    EDIT It appears the user has to enter some data for his profile, otherwise I get this error below. I guess if there is no profile data, the user can not continue to enter data in other tables by default? I do not want to make entering user profile data a requirement to use the rest of the sites functionality, how can I get around this? Currently I have been testing everything with the same user and everything has been working fine. However, when I created a new user for the very first time and tried to enter data into my custom table, I get the following error. The INSERT statement conflicted with the FOREIGN KEY constraint "FK_UserData_aspnet_Profile". The conflict occurred in database "C:\ISTATE\APP_DATA\ASPNETDB.MDF", table "dbo.aspnet_Profile", column 'UserId'. The statement has been terminated. Not sure why I am getting this error. I have the user controls set up in ASP.NET 3.5 however all I am using is my own table or at least that I am aware of. I have a custom UserData table that includes the columns: id, UserProfileID, CL, LL, SL, DateTime (id is the auto incremented int) The intent is that all users will add their data in this table and as I mentioned above it has been working fine for my original first user I created. However, when i created a new user I am getting this problem. Here is the code that updates the database. protected void Button1_Click(object sender, EventArgs e) { //connect to database MySqlConnection database = new MySqlConnection(); database.CreateConn(); //create command object Command = new SqlCommand(queryString, database.Connection); //add parameters. used to prevent sql injection Command.Parameters.Add("@UID", SqlDbType.UniqueIdentifier); Command.Parameters["@UID"].Value = Membership.GetUser().ProviderUserKey; Command.Parameters.Add("@CL", SqlDbType.Int); Command.Parameters["@CL"].Value = InCL.Text; Command.Parameters.Add("@LL", SqlDbType.Int); Command.Parameters["@LL"].Value = InLL.Text; Command.Parameters.Add("@SL", SqlDbType.Int); Command.Parameters["@SL"].Value = InSL.Text; Command.ExecuteNonQuery(); } Source Error: Line 84: Command.ExecuteNonQuery();

    Read the article

  • A Simple Approach For Presenting With Code Samples

    - by Jesse Taber
    Originally posted on: http://geekswithblogs.net/GruffCode/archive/2013/07/31/a-simple-approach-for-presenting-with-code-samples.aspxI’ve been getting ready for a presentation and have been struggling a bit with the best way to show and execute code samples. I don’t present often (hardly ever), but when I do I like the presentation to have a lot of succinct and executable code snippets to help illustrate the points that I’m making. Depending on what the presentation is about, I might just want to build an entire sample application that I would run during the presentation. In other cases, however, building a full-blown application might not really be the best way to present the code. The presentation I’m working on now is for an open source utility library for dealing with dates and times. I could have probably cooked up a sample app for accepting date and time input and then contrived ways in which it could put the library through its paces, but I had trouble coming up with one app that would illustrate all of the various features of the library that I wanted to highlight. I finally decided that what I really needed was an approach that met the following criteria: Simple: I didn’t want the user interface or overall architecture of a sample application to serve as a distraction from the demonstration of the syntax of the library that the presentation is about. I want to be able to present small bits of code that are focused on accomplishing a single task. Several of these examples will look similar, and that’s OK. I want each sample to “stand on its own” and not rely much on external classes or methods (other than the library that is being presented, of course). “Debuggable” (not really a word, I know): I want to be able to easily run the sample with the debugger attached in Visual Studio should I want to step through any bits of code and show what certain values might be at run time. As far as I know this rules out something like LinqPad, though using LinqPad to present code samples like this is actually a very interesting idea that I might explore another time. Flexible and Selectable: I’m going to have lots of code samples to show, and I want to be able to just package them all up into a single project or module and have an easy way to just run the sample that I want on-demand. Since I’m presenting on a .NET framework library, one of the simplest ways in which I could execute some code samples would be to just create a Console application and use Console.WriteLine to output the pertinent info at run time. This gives me a “no frills” harness from which to run my code samples, and I just hit ‘F5’ to run it with the debugger. This satisfies numbers 1 and 2 from my list of criteria above, but item 3 is a little harder. By default, just running a console application is going to execute the ‘main’ method, and then terminate the program after all code is executed. If I want to have several different code samples and run them one at a time, it would be cumbersome to keep swapping the code I want in and out of the ‘main’ method of the console application. What I really want is an easy way to keep the console app running throughout the whole presentation and just have it run the samples I want when I want. I could setup a simple Windows Forms or WPF desktop application with buttons for the different samples, but then I’m getting away from my first criteria of keeping things as simple as possible. Infinite Loops To The Rescue I found a way to have a simple console application satisfy all three of my requirements above, and it involves using an infinite loop and some Console.ReadLine calls that will give the user an opportunity to break out and exit the program. (All programs that need to run until they are closed explicitly (or crash!) likely use similar constructs behind the scenes. Create a new Windows Forms project, look in the ‘Program.cs’ that gets generated, and then check out the docs for the Application.Run method that it calls.). Here’s how the main method might look: 1: static void Main(string[] args) 2: { 3: do 4: { 5: Console.Write("Enter command or 'exit' to quit: > "); 6: var command = Console.ReadLine(); 7: if ((command ?? string.Empty).Equals("exit", StringComparison.OrdinalIgnoreCase)) 8: { 9: Console.WriteLine("Quitting."); 10: break; 11: } 12: 13: } while (true); 14: } The idea here is the app prompts me for the command I want to run, or I can type in ‘exit’ to break out of the loop and let the application close. The only trick now is to create a set of commands that map to each of the code samples that I’m going to want to run. Each sample is already encapsulated in a single public method in a separate class, so I could just write a big switch statement or create a hashtable/dictionary that maps command text to an Action that will invoke the proper method, but why re-invent the wheel? CLAP For Your Own Presentation I’ve blogged about the CLAP library before, and it turns out that it’s a great fit for satisfying criteria #3 from my list above. CLAP lets you decorate methods in a class with an attribute and then easily invoke those methods from within a console application. CLAP was designed to take the arguments passed into the console app from the command line and parse them to determine which method to run and what arguments to pass to that method, but there’s no reason you can’t re-purpose it to accept command input from within the infinite loop defined above and invoke the corresponding method. Here’s how you might define a couple of different methods to contain two different code samples that you want to run during your presentation: 1: public static class CodeSamples 2: { 3: [Verb(Aliases="one")] 4: public static void SampleOne() 5: { 6: Console.WriteLine("This is sample 1"); 7: } 8:   9: [Verb(Aliases="two")] 10: public static void SampleTwo() 11: { 12: Console.WriteLine("This is sample 2"); 13: } 14: } A couple of things to note about the sample above: I’m using static methods. You don’t actually need to use static methods with CLAP, but the syntax ends up being a bit simpler and static methods happen to lend themselves well to the “one self-contained method per code sample” approach that I want to use. The methods are decorated with a ‘Verb’ attribute. This tells CLAP that they are eligible targets for commands. The “Aliases” argument lets me give them short and easy-to-remember aliases that can be used to invoke them. By default, CLAP just uses the full method name as the command name, but with aliases you can simply the usage a bit. I’m not using any parameters. CLAP’s main feature is its ability to parse out arguments from a command line invocation of a console application and automatically pass them in as parameters to the target methods. My code samples don’t need parameters ,and honestly having them would complicate giving the presentation, so this is a good thing. You could use this same approach to invoke methods with parameters, but you’d have a couple of things to figure out. When you invoke a .NET application from the command line, Windows will parse the arguments and pass them in as a string array (called ‘args’ in the boilerplate console project Program.cs). The parsing that gets done here is smart enough to deal with things like treating strings in double quotes as one argument, and you’d have to re-create that within your infinite loop if you wanted to use parameters. I plan on either submitting a pull request to CLAP to add this capability or maybe just making a small utility class/extension method to do it and posting that here in the future. So I now have a simple class with static methods to contain my code samples, and an infinite loop in my ‘main’ method that can accept text commands. Wiring this all up together is pretty easy: 1: static void Main(string[] args) 2: { 3: do 4: { 5: try 6: { 7: Console.Write("Enter command or 'exit' to quit: > "); 8: var command = Console.ReadLine(); 9: if ((command ?? string.Empty).Equals("exit", StringComparison.OrdinalIgnoreCase)) 10: { 11: Console.WriteLine("Quitting."); 12: break; 13: } 14:   15: Parser.Run<CodeSamples>(new[] { command }); 16: Console.WriteLine("---------------------------------------------------------"); 17: } 18: catch (Exception ex) 19: { 20: Console.Error.WriteLine("Error: " + ex.Message); 21: } 22:   23: } while (true); 24: } Note that I’m now passing the ‘CodeSamples’ class into the CLAP ‘Parser.Run’ as a type argument. This tells CLAP to inspect that class for methods that might be able to handle the commands passed in. I’m also throwing in a little “----“ style line separator and some basic error handling (because I happen to know that some of the samples are going to throw exceptions for demonstration purposes) and I’m good to go. Now during my presentation I can just have the console application running the whole time with the debugger attached and just type in the alias of the code sample method that I want to run when I want to run it.

    Read the article

  • 11gr2 DataGuard: Restarting DUPLICATE After a Failure

    - by rene.kundersma
    One of the great new features that comes in very handy when databases get larger and larger these days is RMAN's capability to duplicate from an active database and even restart a duplicate when it fails. Imagine yourself the problem I had lately; I used the duplicate from active database feature and had to wait for an hour or 6 before all datafiles where transferred.At the end of the process some error occurred because of the syntax. While this error was easily to solve I was afraid I had to redo the complete procedure and transfer the 2.5 TB again. Well, 11gr2 RMAN surprised when I re-ran my command with the following output: Using previous duplicated file +DATA/fin2prod/datafile/users.2968.719237649 for datafile 12 with checkpoint SCN of 183289288148 Using previous duplicated file +DATA/fin2prod/datafile/users.2703.719237975 for datafile 13 with checkpoint SCN of 183289295823 Above I only show a small snippet, but what happend is that RMAN smartly skipped all files that where already transferred ! The documentation says this: RMAN automatically optimizes a DUPLICATE command that is a repeat of a previously failed DUPLICATE command. The repeat DUPLICATE command notices which datafiles were successfully copied earlier and does not copy them again. This applies to all forms of duplication, whether they are backup-based (with and without a target connection) or active database duplication. The automatic optimization of the DUPLICATE command can be especially useful when a failure occurs during the duplication of very large databases. If a DUPLICATE operation fails, you need only run the DUPLICATE again, using the same parameters contained in the original DUPLICATE command. Please see chapter 23 of the 11g Release 2 Database Backup and Recovery User's Guide for more details. B.w.t. be very careful with the duplicate command. A small mistake in one of the 'convert' parameters can potentially overwrite your target's controlfile without prompting ! Rene Kundersma Technical Architect Oracle Technology Services

    Read the article

< Previous Page | 219 220 221 222 223 224 225 226 227 228 229 230  | Next Page >