Search Results

Search found 6534 results on 262 pages for 'sgen exe'.

Page 224/262 | < Previous Page | 220 221 222 223 224 225 226 227 228 229 230 231  | Next Page >

  • Not able to use 7-Zip to compress stdin and output with stdout?

    - by acidzombie24
    I get the error "Not implemented". I want to compress a file using 7-Zip via stdin then take the data via stdout and do more conversions with my application. In the man page it shows this example: % echo foo | 7z a dummy -tgzip -si -so /dev/null I am using Windows and C#. Results: 7-Zip 4.65 Copyright (c) 1999-2009 Igor Pavlov 2009-02-03 Creating archive StdOut System error: Not implemented Code: public static byte[] a7zipBuf(byte[] b) { string line; var p = new Process(); line = string.Format("a dummy -t7z -si -so "); p.StartInfo.Arguments = line; p.StartInfo.FileName = @"C:\Program Files\7-Zip\7z.exe"; p.StartInfo.WindowStyle = ProcessWindowStyle.Hidden; p.StartInfo.CreateNoWindow = true; p.StartInfo.UseShellExecute = false; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.RedirectStandardError = true; p.StartInfo.RedirectStandardInput = true; p.Start(); p.StandardInput.BaseStream.Write(b, 0, b.Length); p.StandardInput.Close(); Console.Write(p.StandardError.ReadToEnd()); //Console.Write(p.StandardOutput.ReadToEnd()); return p.StandardOutput.BaseStream.ReadFully(); } Is there another simple way to read the file into memory? Right now I can 1) write to a temporary file and read (easy and can copy/paste some code) 2) use a file pipe (medium? I have never done it) 3) Something else.

    Read the article

  • How do I make C++/wxWidgets code accessible to a wxPython app?

    - by Jon Cage
    I have a code library which is written in C++ and makes extensive use of the wxWidgets library. I'm now trying to wrap my library (currently using SWIG) so that it's callable from wxPython, but I've hit a wall: ------ Build started: Project: MyLibLib, Configuration: Release_SWIG_OutputForBin Win32 ------ Performing Custom Build Step In order to function correctly, please ensure the following environment variables are correctly set: PYTHON_INCLUDE: C:\Python26\include PYTHON_LIB: C:\Python26\libs\python26.lib d:\MyProject\Software\MyLib\trunk\MyLib>C:\swigwin-2.0.0\swig.exe -python d:\MyProject\Software\MyLib\trunk\MyLibLib\MyLib.i d:\MyProject\Software\MyLib\trunk\MyLib>if errorlevel 1 goto VCReportError d:\MyProject\Software\MyLib\trunk\MyLib>goto VCEnd Compiling... MyLib_wrap.c C:\wxWidgets-2.8.10\include\wx/wxchar.h(886) : warning C4273: '_snprintf' : inconsistent dll linkage c:\Program Files\Microsoft Visual Studio 9.0\VC\include\stdio.h(358) : see previous definition of '_snprintf' C:\wxWidgets-2.8.10\include\wx/buffer.h(127) : error C2061: syntax error : identifier 'wxCharBuffer' C:\wxWidgets-2.8.10\include\wx/buffer.h(127) : error C2059: syntax error : ';' C:\wxWidgets-2.8.10\include\wx/buffer.h(127) : error C2449: found '{' at file scope (missing function header?) C:\wxWidgets-2.8.10\include\wx/buffer.h(127) : error C2059: syntax error : '}' C:\wxWidgets-2.8.10\include\wx/buffer.h(127) : error C2059: syntax error : ')' C:\wxWidgets-2.8.10\include\wx/buffer.h(129) : error C2061: syntax error : identifier 'wxWritableCharBuffer' C:\wxWidgets-2.8.10\include\wx/buffer.h(129) : error C2059: syntax error : ';' C:\wxWidgets-2.8.10\include\wx/buffer.h(129) : error C2059: syntax error : ':' C:\wxWidgets-2.8.10\include\wx/buffer.h(134) : error C2061: syntax error : identifier 'wxWCharBuffer' C:\wxWidgets-2.8.10\include\wx/buffer.h(134) : error C2059: syntax error : ';' C:\wxWidgets-2.8.10\include\wx/buffer.h(134) : error C2449: found '{' at file scope (missing function header?) C:\wxWidgets-2.8.10\include\wx/buffer.h(134) : error C2059: syntax error : '}' C:\wxWidgets-2.8.10\include\wx/buffer.h(134) : fatal error C1004: unexpected end-of-file found Build log was saved at "file://d:\MyProject\Software\MyLib\trunk\MyLib\Release_SWIG_OutputForBin\BuildLog.htm" MyLibLib - 13 error(s), 1 warning(s) ========== Build: 0 succeeded, 1 failed, 0 up-to-date, 0 skipped ========== Is there a particular way I should be going about this? I spent some time googling for similar errors, but got none which suggests I'm probably barking up the wrong tree here...? [Edit] Is a dll and ctypes the answer?

    Read the article

  • emacs: Can I set compilation-error-regexp-alist in a mode hook fn?

    - by Cheeso
    I am trying to set the compilation-error-regexp-alist in a function that I add as a mode hook. (defun cheeso-javascript-mode-fn () (turn-on-font-lock) ...bunch of other stuff ;; for JSLINT (make-local-variable 'compilation-error-regexp-alist) (setq compilation-error-regexp-alist '( ("^[ \t]*\\([A-Za-z.0-9_: \\-]+\\)(\\([0-9]+\\)[,]\\( *[0-9]+\\))\\( Microsoft JScript runtime error\\| JSLINT\\): \\(.+\\)$" 1 2 3) )) ;;(make-local-variable 'compile-command) (setq compile-command (let ((file (file-name-nondirectory buffer-file-name))) (concat "%windir%\\system32\\cscript.exe \\cheeso\\bin\\jslint.js " file))) ) (add-hook 'javascript-mode-hook 'cheeso-javascript-mode-fn) The mode hook runs. The various things I Set in the mode hook work. The compile-command gets set. But for some reason, the compilation-error-regexp-alist value doesn't take effect. If I later do a M-x describe-variable on compilation-error-regexp-alist, it shows me the value I think it should have. But .. the errors in the compilation buffer don't get highlighted, and M-x next-error does not work. If I add the error regexp value to the compilation-error-regexp-alist via setq-default, like this: (setq-default compilation-error-regexp-alist '( ... jslint regexp here ... ... many other regexp's here... )) ...then it works. The errors in the compilation buffer get properly highlighted and M-x next-error functions as expected.

    Read the article

  • Easiest way to use speex preprocessor in C#?

    - by eselk
    I need to use the speex preprocessor, and only the preprocessor in my VOIP app (don't need to use the codec). My app is written in C#. I think I know the easiest steps, but not sure where to find these items. Easiest in my opinion, if I can find these: Windows DLL that contains only the preprocessor functions, or if small enough in size I guess the entire speex library would be OK. So far I've only found binarys in EXE format, so if I can't find the binaries I'd have to install the compiler they use to build their source and probably several other libraries (as is my experience with most open source builds). C# versions of the header files, for pinvoking the DLL functions. So my question is, does anyone know where I can find these? I'm sure people have created these before, based on the huge number of speex users, just not able to find any on-line. Hope people don't think I'm lazy, I just hate doing this kind of "busy work" if I know many others have probably already done the exact same thing :) Update: I did find http://www.rarewares.org/files/others/libspeex-dll-1.2rc1.zip which includes libspeex.dll, but the DLL has no exports so not sure how they expect that to work. The other binaries they have are also just EXEs.

    Read the article

  • Statically Compiling QWebKit 4.6.2

    - by geeko
    I tried to compile Qt+Webkit statically with MS VS 2008 and this worked. C:\Qt\4.6.2configure -release -static -opensource -no-fast -no-exceptions -no-accessibility -no-rtti -no-stl -no-opengl -no-openvg -no-incredibuild-xge -no-style-plastique -no-style-cleanlooks -no-style-motif -no-style-cde -no-style-windowsce -no-style-windowsmobile -no-style-s60 -no-gif -no-libpng -no-libtiff -no-libjpeg -no-libmng -no-qt3support -no-mmx -no-3dnow -no-sse -no-sse2 -no-iwmmxt -no-openssl -no-dbus -platform win32-msvc2008 -arch windows -no-phonon -no-phonon-backend -no-multimedia -no-audio-backend -no-script -no-scripttools -webkit -no-declarative However, I get these errors whenever building a project that links statically to QWebKit: 1 Creating library C:\Users\Geeko\Desktop\Qt\TestQ\Release\TestQ.lib and object C:\Users\Geeko\Desktop\Qt\TestQ\Release\TestQ.exp 1QtWebKit.lib(PluginPackageWin.obj) : error LNK2019: unresolved external symbol _VerQueryValueW@16 referenced in function "class WebCore::String __cdecl WebCore::getVersionInfo(void * const,class WebCore::String const &)" (?getVersionInfo@WebCore@@YA?AVString@1@QAXABV21@@Z) 1QtWebKit.lib(PluginPackageWin.obj) : error LNK2019: unresolved external symbol _GetFileVersionInfoW@16 referenced in function "private: bool __thiscall WebCore::PluginPackage::fetchInfo(void)" (?fetchInfo@PluginPackage@WebCore@@AAE_NXZ) 1QtWebKit.lib(PluginPackageWin.obj) : error LNK2019: unresolved external symbol _GetFileVersionInfoSizeW@8 referenced in function "private: bool __thiscall WebCore::PluginPackage::fetchInfo(void)" (?fetchInfo@PluginPackage@WebCore@@AAE_NXZ) 1QtWebKit.lib(PluginDatabaseWin.obj) : error LNK2019: unresolved external symbol _imp_PathRemoveFileSpecW@4 referenced in function "class WebCore::String __cdecl WebCore::safariPluginsDirectory(void)" (?safariPluginsDirectory@WebCore@@YA?AVString@1@XZ) 1QtWebKit.lib(PluginDatabaseWin.obj) : error LNK2019: unresolved external symbol _imp_SHGetValueW@24 referenced in function "void __cdecl WebCore::addWindowsMediaPlayerPluginDirectory(class WTF::Vector &)" (?addWindowsMediaPlayerPluginDirectory@WebCore@@YAXAAV?$Vector@VString@WebCore@@$0A@@WTF@@@Z) 1QtWebKit.lib(PluginDatabaseWin.obj) : error LNK2019: unresolved external symbol _imp_PathCombineW@12 referenced in function "void __cdecl WebCore::addMacromediaPluginDirectories(class WTF::Vector &)" (?addMacromediaPluginDirectories@WebCore@@YAXAAV?$Vector@VString@WebCore@@$0A@@WTF@@@Z) 1C:\Users\Geeko\Desktop\Qt\TestQ\Release\TestQ.exe : fatal error LNK1120: 6 unresolved externals Do I need to check something in the Qt project options ? I have QtCore, QtGui, Network and WebKit checked.

    Read the article

  • Windows 7 64 Bit - ODBC32 - Legacy App Problem

    - by Arturo Caballero
    Good day StackOverFlowlers, I´m a little stuck (really stuck) with an issue with a legacy application on my organization. I have a Windows 7 Enterprise 64 Bit machine, Access 2000 Installed and the Legacy App (Is built with something like VB but older) The App uses System ODBC in order to connect to a SQL 2000 DataBase on a Remote Server. I created the ODCB using C:\Windows\SysWOW64\odbcad32.exe app in order to create a System DSN. I did not use the Windows 7 because it is not visible to the Legacy App. I tested the ODBC connection with Access and worked ok, I can access the remote database. Then I run the legacy App as Administrator and the App can see the ODBC, but I´m getting errors on credential validation and I´m getting this error: DIAG [08001] [Microsoft][ODBC SQL Server Driver][Multi-Protocol]SQL Server does not exist or access denied. (17) DIAG [01000] [Microsoft][ODBC SQL Server Driver][Multi-Protocol]ConnectionOpen (Connect()). (53) DIAG [IM006] [Microsoft][ODBC Driver Manager] Driver's SQLSetConnectAttr failed (0) I use Trusted Connection on the ODBC in order to validate the user by Domain Controller. I think that the credentials are not being sent by the Legacy App to the ODBC, or something like that. I don´t have the source code of the Legacy App in order to debug the connection. Also, I turned off the Firewall. Any ideas?? Thanks in advance!

    Read the article

  • Apache unresponsive on Vista [closed]

    - by William Hudson
    I had been running Apache on Vista for around a year, but recently upgraded my workstation. I did a clean install of Vista Ultimate and installed the latest version of the Apache server for win32 (2.2.11, no SSL). The service runs fine and there were no errors reported during the install, nor are there any errors in the Apache logs. However, any attempt to access the web site on localhost (or 127.0.0.1) just hangs the browser. I have used netstat to check who is listening to port 80 and it shows httpd.exe. I have also tried adjusting the .conf file to use port 8080 but this had no effect either (except to change the netstat output). This is a development system with quite a few other pieces of software installed. However, when I tried installing IIS, it worked fine (I removed it soon after before reattempting the Apache install). Using the older 2.0 version of Apache has no effect. Windows firewall is not running. I have disabled my NOD32 anti-virus. Any ideas what is going on? Regards, William

    Read the article

  • mono --aot with MinGW: unknown pseudo-op: `.local'

    - by Jared Updike
    Can I user mono's AOT feature to natively "pre-compile" .NET DLLs (and or EXEs) to make them harder to reverse engineer? If so, how do I get mono/AOT working in Windows 7? (I'm running x64 but the app is targeting x86 explicitly.) I just installed Mono 2.6.3 and MinGW 5.1.6 and I'm trying to AOT compile an exe (or a dll, it doesn't matter). I get screens and screens of error messages: C:\Users\jupdike\AppData\Local\Temp\mono_aot_XSDEAV:533: Error: junk at end of line, first unrecognized character is `H' C:\Users\jupdike\AppData\Local\Temp\mono_aot_XSDEAV:539: Error: unknown pseudo-op: `.local' C:\Users\jupdike\AppData\Local\Temp\mono_aot_XSDEAV:546: Warning: .size pseudo-op used outside of .def/.endef ignored. C:\Users\jupdike\AppData\Local\Temp\mono_aot_XSDEAV:546: Error: junk at end of line, first unrecognized character is `H' I can open the generated assembly code but I have no idea why the assembler chokes on it: .size HappyForms_TextForm__ctor_string_string_string_bool,.-HappyForms_TextForm__ctor_string_string_string_bool (533) _.Lme_a: .Lme_a: .balign 16 _.Lm_b: .Lm_b: .local HappyForms_TextForm_get_InputValue (539) _HappyForms_TextForm_get_InputValue: HappyForms_TextForm_get_InputValue: .byte 85,139,236,131,236,8,139,69,8,139,128,216,2,0,0,131,236,12,80,139,0,144,144,144,255,144,200,2,0,0,131,196 .byte 16,201,195 .size HappyForms_TextForm_get_InputValue,.-HappyForms_TextForm_get_InputValue (546) (numbers above in parens are line numbers)

    Read the article

  • Help with debugging COM errors? (.mdi to .pdf file conversions using Microsoft Office Document Imagi

    - by RyanW
    I thought I had a working solution for converting .mdi files to PDF using the Microsoft Office Document Imaging object model. The solution is in a Windows Service, but now I'm running into some errors that I'm having trouble tracking down info on. The exception I get is: The server threw an exception. (Exception from HRESULT: 0x80010105 (RPC_E_SERVERFAULT)) System.Runtime.InteropServices.COMException (0x80010105): The server threw an exception. (Exception from HRESULT: 0x80010105 (RPC_E_SERVERFAULT)) at MODI.DocumentClass.Create(String FileOpen) at DocumentStore.Mdi2PDF(String path, String newPath) Then, in the Event Viewer there is the following Application error: Faulting application MyWindowsServiceName.exe, version 1.0.0.0, time stamp 0x4b97f185, faulting module mso.dll, version 12.0.6425.1000, time stamp 0x49d65443, exception code 0xc0000005, fault offset 0x0000bd8e, process id 0xa5c, application start time 0x01cac08cf032914b. Here's the method that is doing the conversion: private int? Mdi2PDF(String path, String newPath) { int? pageCount = null; string tmpTif = Path.GetTempFileName(); MODI.Document mdiDoc = new MODI.Document(); mdiDoc.Create(path); mdiDoc.SaveAs(tmpTif, MODI.MiFILE_FORMAT.miFILE_FORMAT_TIFF_LOSSLESS, MODI.MiCOMP_LEVEL.miCOMP_LEVEL_HIGH); mdiDoc.Close(false); pageCount = Tiff2PDF(tmpTif, newPath); if (File.Exists(tmpTif)) File.Delete(tmpTif); return pageCount; } I removed all threading from the service invoking this, so that only the primary thread was initializing the MODI object, but still got the error, so it doesn't appear to be threading related. I also built a a console apps converting hundreds of documents and DID NOT get the exception. So, it seems to be caused by creating too many instances of the MODI object, but only instantiated within a Service? Doesn't quite make sense. Anybody have any clues about these errors and how to debug them further?

    Read the article

  • Automating ftp command line application redirecting I/O in .Net

    - by SoMoS
    Hello, I'm trying to automate the ftp client that Windows includes redirecting the I/O from the process. What I'm doing is starting the process from my application and trying to read what the client prints on the screen and sending my commands to it. The problem is that I can not read almost any data sent by the ftp client. Some data is present but most data is not read. That's the code I have until now. Public Sub Start() process = New Diagnostics.Process() process.StartInfo.FileName = "ftp.exe" #'' The command is on the path process.StartInfo.CreateNoWindow = True process.StartInfo.RedirectStandardInput = True process.StartInfo.RedirectStandardOutput = True process.StartInfo.UseShellExecute = False process.Start() process.StandardInput.AutoFlush = True process.BeginOutputReadLine() End Sub #'' takes data from the stdout Private Sub process_OutputDataReceived(ByVal sender As Object, ByVal e As System.Diagnostics.DataReceivedEventArgs) Handles process.OutputDataReceived #'' At this moment here there is code to show the stdout at a textbox End Sub #'' sends data to stdin Private Sub Button2_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Button2.Click process.StandardInput.WriteLine(Me.TextEdit1.Text) End Sub Now when I execute this for example and send ? I just get the first line (and I should get a lot more). Or when I send the open command I should receive an A but nothing is received. Any ideas? Another question is ... when a console applications writes on the screen it always does that by writing at the stdout or the stderr isn't it?

    Read the article

  • Com server build using Python on 64-bit Windows 7 machine

    - by Vijayendra Bapte
    Original post is here: http://mail.python.org/pipermail/python-win32/2010-December/011011.html I am using: OS: 64 bit Windows 7 Professional Python: python-2.7.1.amd64 Python win32 extensions: pywin32-214.win-amd64-py2.7 Py2exe: py2exe-0.6.9.win64-py2.7.amd64 I am trying to build icon overlay for Windows. It has worked fine on 32 bit Windows but not working on 64 bit Windows 7. Here are the Python modules I have created for testing: test_icon_overlay.py: ( http://mail.python.org/pipermail/python-win32/attachments/20101229/bb8c78a4/attachment-0002.obj ) com server created in Python for icon overlay which adds check mark overlay icon(C:\icons\test.ico) on "C:\icons" folder setup_VI.py: ( http://mail.python.org/pipermail/python-win32/attachments/20101229/bb8c78a4/attachment-0003.obj ) setup file which creates test_icon_overlay.dll for distribution. icons.zip: ( http://mail.python.org/pipermail/python-win32/attachments/20101229/bb8c78a4/attachment-0001.zip ) for testing you should extract icons.zip inside C:\ Icon overlay appears on C:\icons folder when I execute python test_icon_overlay.py on Windows command prompt and restarts explorer.exe. But its not working with the dll file created using setup_VI.py I have created dll file using python setup_VI.py py2exe and then tried to register it using regsvr32 test_icon_overlay.dll. Registration fails with windows error message Error 0x80040201 while registering shell extension. Then I turned on logger in Python27/Lib/site-packages/py2exe/boot_com_servers.py and here is the traceback which I am getting in comerror.txt on regsvr32 test_icon_overlay.dll PATH is ['C:\\root\\avalon\\module\\sync\\python\\src\\dist\\library.zip'] Traceback (most recent call last): File "boot_com_servers.py", line 37, in <module> pywintypes.error: (126, 'GetModuleFileName', 'The specified module could not be found.') Traceback (most recent call last): File "<string>", line 1, in <module> NameError: name 'DllRegisterServer' is not defined Looks like there might be a problem with win32api.GetModuleFileName(sys.frozendllhandle) or with the dll build on 64-bit Windows 7. Also, I saw that installation of pywin32-214.win-amd64-py2.7 on 64-bit Windows 7 finish with the error message: Snapshot close failed in file object destructor: sys.excepthook is missing lost sys.stderr Is there anything which I am doing wrong? Any help on this is highly appreciated.

    Read the article

  • Remote DLL Registration without access to HKEY_CLASSES_ROOT

    - by mohlsen
    We have a legacy VB6 application that updates itself on startup by pulling down the latest files and registering the COM components. This works for both local (regsvr32) ActiveX COM Components and remote (clireg32) ActiveX COM components registered in COM+ on another machine. New requirements are preventing us from writing to HKEY_LOACL_MACHINE (HKLM) for security reasons, which is what obviously happens by default when calling regsvr32 and clireg32. We have come up with an way to register the local COM componet under HKEY_CURRENT_USER\Software\Classes (HKCU) using the RegOverridePredefKey Windows API method. This works by redirecting the inserts into the registry to the HKCU location. Then when the COM components are instantiated, windows first looks to HKCU before looking for component information in HKLM. This replaces what regsvr32 is doing. The problem we are experiencing at this time is when we attempt to register VBR / TLB using clireg32, this registration process also adds registration keys to HKEY_LOACL_MACHINE. Is there a way to redirect clireg32.exe to register component is HKEY_CURRENT_USER? Are there any other methods that would allow us to register these COM+ components on clients machine with limited security access? Our only solution at this time would be to manually write the registration information to the registry, but that is not ideal and would be a maint issue.

    Read the article

  • VS2010 compiles solution without errors, msbuild fails: "fatal error CS0002: Unable to load message string from resources"

    - by Nathan Ridley
    I'm having a lot of trouble trying to track down the cause of this error message. I have a large Visual Studio 2010 solution which compiles without error on my local machine but on the build server, msbuild fails on one of the projects with the error: fatal error CS0002: Unable to load message string from resources Here's the red error section at the end: Build FAILED. "C:\TeamCity\buildAgent\work\85eff164854b9e67\Libraries\Domainface.Proxy.Common\Domainface.Proxy.Common.csproj" (default target) (9) -> (CoreCompile target) -> CSC : fatal error CS0002: Unable to load message string from resources. [C:\TeamCity\buildAgent\work\85eff164854b9e67\Libraries\Domainface.Proxy.Common\Domainface.Proxy.Common.csproj] 0 Warning(s) 1 Error(s) The entire msbuild output from the build server is here: http://pastie.org/3660842 What does the error generally refer to, that would cause it to build locally but not on the build server? UPDATE I have just run msbuild /version on both machines and it turns out the .net framework versions are very slightly different. Local machine is 4.0.30319.488 and build server is 4.0.30319.1. I'm about to run windows update on the server to allow it to install some updates, as several seem to be .net framework-related, so I'll see if that makes a difference. UPDATE Installing the updates didn't help. Just remembered I copied up csc.exe from the async preview a little while ago in order to facilitate async compilation (the actual async preview had failed to install on the server due to visual studio not being there, but installing visual studio team viewer seems to have fixed that, so i've just run the proper async ctp3 installer to see if that makes a difference.

    Read the article

  • How to eliminate Unhandled Exception dialog produced by 3rd party application

    - by Tappen
    I'm working with a 3rd party executable that I can't recompile (vendor is no longer available). It was originally written under .Net 1.1 but seems to work fine under later versions as well. I launch it using Process.Start from my own application (I've tried p/invoke CreateProcess as well with the same results so that's not relevant) Unfortunately this 3rd party app now throws an unhandled exception as it exits. The Microsoft dialog box has a title like "Exception thrown from v2.0 ... Broadcast Window" with the version number relating to the version of .Net it's running under (I can use a .exe.config file to target different .Net versions, doesn't help). The unhandled exception dialog box on exit doesn't cause any real problems, but is troubling to my users who have to click OK to dismiss it every time. Is there any way (a config file option perhaps) to disable this dialog from showing for an app I don't have the source code to? I've considered loading it in a new AppDomain which would give me access to the UnhandledException event but there's no indication I could change the appearence of the dialog. Maybe someone knows what causes the exception and I can fix this some other way?

    Read the article

  • ASP.NET Chart Control errors in Event Viewer

    - by Richard Reddy
    Hi, I have been using the ASP.NET chart controls for a while on win2k3 (32bit) setups without any issue but have noticed that on our new win2k8 (64bit) box I am getting a warning message showing up in the event viewer from the chart control. In my web.config file I have the following tag telling the Chart Control where I can store the Temp Files: <add key="ChartImageHandler" value="storage=file;timeout=20;dir=c:\TempImageFiles\;" /> Below is the warning message produced by the control: Event code: 3005 Event message: An unhandled exception has occurred. Event time: 10/7/2009 2:40:03 PM Event time (UTC): 10/7/2009 2:40:03 PM Event ID: 237c3b208962429e8bbc5a48ffd177f0 Event sequence: 2860 Event occurrence: 26 Event detail code: 0 Application information: Application domain: /LM/W3SVC/2/ROOT-1-128993655360497729 Trust level: Full Application Virtual Path: / Application Path: C:\data\sites\mydomain.com\ Machine name: 231692-WEB Process information: Process ID: 4068 Process name: w3wp.exe Account name: NT AUTHORITY\NETWORK SERVICE Exception information: Exception type: ArgumentException Exception message: The image is not found. Request information: Request URL: http://www.mydomain.com/ChartImg.axd?i=chart%5F0%5F3.png&g=bccc8aa11abb470980c60e8cf1e71e15 Request path: /ChartImg.axd User host address: my domain ip User: Is authenticated: False Authentication Type: Thread account name: NT AUTHORITY\NETWORK SERVICE Thread information: Thread ID: 7 Thread account name: NT AUTHORITY\NETWORK SERVICE Is impersonating: False Stack trace: at System.Web.UI.DataVisualization.Charting.ChartHttpHandler.ProcessSavedChartImage(HttpContext context) at System.Web.UI.DataVisualization.Charting.ChartHttpHandler.System.Web.IHttpHandler.ProcessRequest(HttpContext context) at System.Web.HttpApplication.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() at System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) It's worth pointing out that ALL of the chart images are displayed correctly on the screen so I'm not sure when/where the image not found error is being caused. Is this a 64bit issue? Thanks, Rich

    Read the article

  • Linq Query to Update Nested Array Items?

    - by Brett
    I have an object structure generated from xsd.exe. Roughly, it consists of 3 nested arrays: protocols, sources and reports. The xml looks like this: <protocols> <protocol> <source> <report /> <report /> </source> <source> <report /> <report /> </source> </protocol> <!-- more protocols --> </protocols> I need to update a single "Report" within the data structure. A brute force algorithm is shown below. I know that this could be done using XDocument and Linq, but I'd prefer to update the data structure and then serialize the structure back to disk. Thoughts? Brett bool updated = false; foreach (ProtocolsProtocol protocol in protocols.Protocol) { if (updated) break; foreach (ProtocolsProtocolSource source in protocol.Source) { if (updated) break; for (int i = 0; i < source.Report.Length; i++) { ProtocolsProtocolSourceReport currentReport = source.Report[i]; if (currentReport.Id == report.Id) { currentReport.Attribute1 = report.Attribute1; currentReport.Attribute2 = report.Attribute2; updated = true; break; } } } }

    Read the article

  • Precompiled headers question

    - by Kotti
    Hello! I am right now reorganizing my project and what recently was a simple application now became a pair of C++ projects - static library and real application. I would like to share one precompiled header between two projects, but face some troubles with setting up the .pdb file paths. Assume my first project is called Library and builds it's .lib file with a corresponding Library.pdb file. Now, the second project is called Application and builds everything into the same folder (.exe and another Application.pdb file). Right now my both projects create their own precompiled headers file (Library.pch and Application.pch) based on one actual header file. It works, but I think it's a waste of time and I also think there should be a way to share one precompiled header between two projects. If in my Application project I try to set the Use Precompiled Header (/Yu) option and set it to Library.pch, it wouldn't work, because of the following error: error C2858: command-line option 'program database name "Application.pdb" inconsistent with precompiled header, which used "Library.pdb". So, does anyone know some trick or way to share one precompiled header between two projects preserving proper debug information?

    Read the article

  • Can't write the SysWow64 value to registry with vbscript for Screensaver

    - by Valentein
    Scripts, registries, screen-savers, oh my! I'm trying to use a screen-saver on a Windows XP 64 bit machine which uses a .NET app which makes an interop call which relies on some x86 Shockwave Dlls (some Shockwave animation). Everything should be in the %systemroot%\WINNT\SysWOW64 directory. When the timeout for the screensaver occurs, the process should looks like this: Screensaver.scr - .NET app - shockwave animation. During installation I want a vbscript to my screen-saver file to copy the Screensaver.scr to the SysWow64 directory and then set the proper registry key to this file for Windows to launch the screen-saver. The code is something like this: Dim sScreenSaver, tScreenSaver sScreenSaver = "C:\SourceFiles\bin\ScreenSaver.scr" 'screensaver tScreenSaver = "C:\winnt\SysWOW64\" Set WshShell = WScript.CreateObject("WScript.Shell") 'script shell to run objects Set FSO = createobject("scripting.filesystemobject") 'file system object 'copy screensaver FSO.CopyFile sScreenSaver, tScreenSaver, True 'set screen saver Dim p1 p1 = "HKEY_CURRENT_USER\Control Panel\Desktop\" WshShell.RegWrite p1 & "SCRNSAVE.EXE", (tScreenSaver & "ScreenSaver.scr") After installation, I can verify the the Screensaver exists in the correct directory. (It actually seems to be in both the system32 and the sysWOW64 directories---whether that's the install script or something I did post-install I'm in the process of verifying.) However, the registry entry is not correct. In both the 32 and 64 bit regedit I see the HKCU\ControlPanel\Desktop\SCRNSAVE.EX is set to: C:\WINNT\system32\Screensaver.scr This isn't right. The screen-saver won't run from this directory. It only runs from SysWOW64. If I manually edit the registry with regedit to the correct SysWOW64 path everything works fine. Is this a problem with using the script or is this a Windows registry redirection, or filesystem redirection problem? You'd think this would be simple...

    Read the article

  • Can't debug Java Windows Services with jhat, jps, jstack

    - by Matthew McCullough
    I frequently showcase the jhat, jps, and jstack tool set to developers on Linux and Mac. However, a developer recently indicated that these are unusable in Windows if the Java app in question is running as a Windows Service. A Sun-filed bug says something very similar, but was closed due to inactivity. I have tested this out for myself, and indeed it appears true, though I can hardly believe it. Here is the setup: Tomcat or similar running as a Windows service with the "Log On As" == "Local System" A user with Admin privileges logged in to the same Windows machine. Admin opens Windows Task Manager, can see java.exe running Admin opens console, types "jps", gets back a list of processes that does not include Tomcat's java service process. As a brute force attempt, get the PID of tomcat as a service from Windows Task Manager. Type jstack < pid . Get a reply: < pid no such process This appears reproducible under Windows XP, Windows 2003 Server, and Windows 7. Java versions 1.5 and 1.6 yield the same outcome. Is there a way from the terminal, even though logged in as Admin, to "sudo up" to get JPS and the other tools to see the java service?

    Read the article

  • H.264 / FLV best practices for HTML

    - by Steve Murch
    I run a website with about 700 videos (And no, it's not porn -- get your mind out of the gutter :-) ). The videos are currently in FLV format. We use the JWPlayer to render those videos. IIS6 hosted. Everything works just fine. As I understand it, H.264 (not FLV and likely not OGG) is the emerging preferred HTML5 video standard. Today, the iPad really only respects H.264 or YouTube. Presumably, soon many more important browsers will follow Apple's lead and respect only the HTML5 tag. OK, so I think I can figure out how to convert my existing videos into the proper H.264 format. There are various tools available, including ffmpeg.exe. I haven't tried it yet, but I don't think that's going to be a problem after fiddling with the codec settings. My question is more about the container itself -- that is, planning graceful transition for all users. What's the best-practice recommendation for rendering these videos? If I just use the HTML5 tag, then presumably any browser that doesn't yet support HTML5 won't see the videos. And if I render them in Flash format via the JWPlayer or some other player, then they won't be playable on the iPad. Do I have to do ugly UserAgent detection here to figure out what to render? I know the JWPlayer supports H.264 media, but isn't the player itself a Flash component and therefore not playable on the iPad? Sorry if I'm not being clear, but I'm scratching my head on a graceful transition plan that will work for current browsers, the iPad and the upcoming HTML5 wave. I'm not a video expert, so any advice would be most welcome, thanks.

    Read the article

  • How to display NotifyIcon and SSDP Service running during AutoLogon

    - by Paul Farry
    I've got an application (that is targetting .Net Framework 2.0) that is running on startup of the System, and I'm trying to get a NotifyIcon to display. When my program starts up when a user either Runs it normally or is started as a child process after the system has already logged on everything is fine. If my application starts up as the system is performing an AutoLogon using POSReady2009 (basically XP with Single User set). Then the NotifyIcon never becomes active. If you subsequently check (in a timer) the .Visible of the Icon at any point later it always reports that it is visible = true. If you disable the SSDPSrv and restart the Computer, the Icon displays correctly. I have a sneaking suspicion this is related to .Net 3.5sp1 installed over the top of a .Net 2 system. Is there some process that I should be following to ensure that my NotifyIcon is always available to the user. I have setup RegisterWindowMessage("TaskbarCreated") but I don't get this message called, except when you forcilbly Kill Explorer.exe and restart it. Even so, a NotifyIcon interally registers for these notifications anyway, so it shouldn't be required. I'm happy to stall the startup of my program, but once the program starts up, I expect that the icon shows correctly. If there is a KB article that I cannot find detailing this I'd be happy with that too.

    Read the article

  • Create win task to run once and delete immediately using C#

    - by pencilslate
    Here is the use case: - Create a new win task, run immediately and once complete, delete the task. Here is basic code to create a task using C#. using (TaskService ts = new TaskService(null)) { string projectName = "runnowtest" + Guid.NewGuid().ToString(); //create new task TaskDefinition td = ts.NewTask(); Trigger mt = null; //setup task as Registration trigger mt = td.Triggers.AddNew(TaskTriggerType.Registration); mt.StartBoundary = DateTime.Now; //delete the task 1 minute after the program ends td.Settings.DeleteExpiredTaskAfter = new TimeSpan(0, 1, 0); //run the notepad++ in the task td.Actions.Add(new ExecAction("notepad.exe")); //register task Task output = ts.RootFolder.RegisterTaskDefinition(projectName, td); //check output Console.WriteLine(output != null ? "Task created" : "Task not created"); } The API doesn't seem to have a property/flag to mark task as run once. I am trying to ensure the above task runs only once and deletes immediately after that. Any thoughts are much appreciated!

    Read the article

  • Creating customized .dmg files upon download

    - by Marten
    I want to distribute a cross-platform application for which the executable file is slightly different, depending on the user who downloaded it. This is done by having a placeholder string somewhere in the executable that is replaced with something user-specific upon download. The webserver that has to do these string replacements is a Linux machine. For Windows, the executable is not compressed in the installer .exe, so the string replacement is easy. For uncompressed Mac OS X .dmg files, this is also easy. However, .dmg files that are compressed with either gzip or bzip2 are not so easy. For example, in the latter case, the compressed .dmg is not one big bzip2-compressed disk image, but instead consists of a few different bzip2-compressed parts (with different block sizes) and a plist suffix. Also, decompressing and recompressing the different parts with bzip2 does not result in the original data, so I'm guessing Apple uses some different parameters to bzip2 than the command-line tool. Is there a way to generate a compressed .dmg from an uncompressed one on Linux (which does not have hdiutil)? Or maybe another suggestion for creating customized applications without pregenerating them? It should work without any input by the user.

    Read the article

  • Build System with Recursive Dependency Aggregation

    - by radman
    Hi, I recently began setting up my own library and projects using a cross platform build system (generates make files, visual studio solutions/projects etc on demand) and I have run into a problem that has likely been solved already. The issue that I have run into is this: When an application has a dependency that also has dependencies then the application being linked must link the dependency and also all of its sub-dependencies. This proceeds in a recursive fashion e.g. (For arguments sake lets assume that we are dealing exclusively with static libraries.) TopLevelApp.exe dependency_A dependency_A-1 dependency_A-2 dependency_B dependency_B-1 dependency_B-2 So in this example TopLevelApp will need to link dependency_A, dependency_A-1, dependency_A-2 etc and the same for B. I think the responsibility of remembering all of these manually in the target application is pretty sub optimal. There is also the issue of ensuring the same version of the dependency is used across all targets (assuming that some targets depend on the same things, e.g. boost). Now linking all of the libraries is required and there is no way of getting around it. What I am looking for is a build system that manages this for you. So all you have to do is specify that you depend on something and the appropriate dependencies of that library will be pulled in automatically. The build system I have been looking at is premake premake4 which doesn't handle this (as far as I can determine). Does anyone know of a build system that does handle this? and if there isn't then why not?

    Read the article

  • SQL Compact allow only one WCF Client

    - by Andreas Hoffmann
    Hi, I write a little Chat Application. To save some infos like Username and Password I store the Data in an SQL-Compact 3.5 SP1 Database. Everything working fine, but If another (the same .exe on the same machine) Client want to access the Service. It came an EndpointNotFound exception, from the ServiceReference.Class.Open() at the Second Client. So i remove the CE Data Access Code and I get no Error (with an if (false)) Where is the Problem? I googled for this, but no one seems the same error I get :( SOLUTION I used the wrapper in http://csharponphone.blogspot.com/2007/01/keeping-sqlceconnection-open-and-thread.html for threat safty, and now it works :) Client Code: public test() { var newCompositeType = new Client.ServiceReference1.CompositeType(); newCompositeType.StringValue = "Hallo" + DateTime.Now.ToLongTimeString(); newCompositeType.Save = (Console.ReadKey().Key == ConsoleKey.J); ServiceReference1.Service1Client sc = new Client.ServiceReference1.Service1Client(); sc.Open(); Console.WriteLine("Save " + newCompositeType.StringValue); sc.GetDataUsingDataContract(newCompositeType); sc.Close(); } Server Code public CompositeType GetDataUsingDataContract(CompositeType composite) { if (composite.Save) { SqlCeConnection con = new SqlCeConnection(Properties.Settings.Default.Con); con.Open(); var com = con.CreateCommand(); com.CommandText = "SELECT * FROM TEST"; SqlCeResultSet result = com.ExecuteResultSet(ResultSetOptions.Scrollable | ResultSetOptions.Updatable); var rec = result.CreateRecord(); rec["TextField"] = composite.StringValue; result.Insert(rec); result.Close(); result.Dispose(); com.Dispose(); con.Close(); con.Dispose(); } return composite; }

    Read the article

< Previous Page | 220 221 222 223 224 225 226 227 228 229 230 231  | Next Page >