Search Results

Search found 7371 results on 295 pages for 'raid card'.

Page 23/295 | < Previous Page | 19 20 21 22 23 24 25 26 27 28 29 30  | Next Page >

  • Installing Linux from External Card Reader

    - by Subhamoy Sengupta
    I have this problem. I was experimenting if I could use a memory card (SDHC) as an USB drive for all intents and purposes, and when I put the card in an USB card reader, I can use it just like regular USB stick and it also shows up in the BBS popup menu as an USB stick. When I tried to create an installation media out of it like this: sudo dd if=/path/to/image of=/dev/sdb And tried to boot from it, simply nothing happened. Cursor blinked a couple times, and jumped to the GRUB of my pre-existing GNU/Linux installation. What am I missing here? Is this not doable? I tried this with Xubuntu 12.04 and ArchLinux, by the way. I have also tried UNetBootIn instead of dd. Nothing happened differently.

    Read the article

  • MacPro 1,1 video's card

    - by alexus
    I just bought a Mac Pro 1,1 from my coworkers and I'm looking to upgrade video card as the one inside is very noisy. What are my options? Basically I'm not looking to spend a lot of money, in fact i'd rather to spend as little as possible and get low end or mid range card, I'm not really playing games all that much so pretty much anything will do, I'd prefer 2xx series though. Current Mac Pro sells w/ GT120, Apple sells upgrade kit for $149 (which is okay, I just not sure if I'll be able to use this card on such an old Mac Pro)

    Read the article

  • Updating ATI HD 5970 Graphics card - version errors?

    - by user55406
    I'm having an issue...My system specs is: Intel i7 960 6GM Corair XMS RAM ATI HD5970 graphics card Intel dx58so motherboard Cooler Master HAF 922 case 1.5TB Seagate hard drive Windows Vista x86 (32-bit). Here is my issue: when I go to AMD/ATI website to update my graphics card - it doesn't. when I type DxDiag and then click on display it tell me my version is 8.17.0 and its on 10.10.0 for the latest version. How can I get 8.17.0 too 10.10.0? I figure it would have done that after I updated the driver for my graphics card. Thanks.

    Read the article

  • Monitor has yellow tint when used with the graphics card

    - by artknish
    I have an nVIDIA graphics card when used produces an yellow tint on my monitor's display. I tried with another monitor and it had the same issue. I then switched back to my motherboard's inbuilt graphics output (not sure what the technical term is), and the display seems fine, except I can't get the optimal resolution of 1440x900 to work. So is my graphics card's life over? Or can I get it repaired? Any self remedies without calling a hardware guy? Should I try with a DVI cable? I've been using the VGA cable from my graphics card to the monitor so far. Thanks for your suggestions!

    Read the article

  • Asus F5N laptop built-in card reader driver problem

    - by Felix Dombek
    I have an Asus F5N X50N-AP011C. I have manually installed Windows 7 x64 on it, replacing the original Windows Vista. It also automatically installed a card reader driver, but it can no longer read xD cards. The driver shows in the device manager as "Generic- xD/SDMMC/MS/Pro USB device" (under "drives" - and a drive is also shown in Windows Explorer). The same card reader once used to work with xD cards. I also tried to manually install drivers from this website: http://www.station-drivers.com/page/realtek.htm - the RTS 5158 but it didn't work (it shows as USB device in device manager, but not as a drive in Windows Explorer). Does anyone know what card reader my model has built-in? (I think it's the 5158 but I don't know how to verify that - there's also no hint in the System Information tool, only the driver name is listed under "drives") how it is connected internally? if there is a better Windows 7 x64 driver?

    Read the article

  • LSI RAID monitor reports "Consistency Check inconsistency logging disabled"

    - by carlpett
    I have a server with a LSI MegaRAID 9261-8i controller. Recently I started getting alerts like this one: Controller ID: 1 Consistency Check inconsistency logging disabled, too many inconsistencies on VD: 0 Generated on:Sat May 12 04:06:40 2012 SYSTEM DETAILS--- IP Address: 192.168.1.29 OS Name: Windows 7 x64 OS Version: 6.01 Driver Name: megasas.sys Driver Version: 4.5.1.64 IMAGE DETAILS--- BIOS Version: 2.120.33-1197 Firmware Package Version: 12.12.0-0045 Firmware Version: 3.21.00_4.11.05.00_0x05000000 VD 0 is a RAID mirror containing the system disk. I have searched and read, but cannot find any trace of how to actually do anything about this. I tried running a scandisk but that did not find anything (as I expected, since scandisk reads the disks as exposed by the controller, right?). The MegaRAID Storage Manager does not as far as I can see have any options for checking or fixing physical disks. The program claims the VD is "healty", and both disks have Error count 0. Also a bit strange is the System details in the message... The IP address is associated with the RAS (dial in) interface, and the OS should be Windows Server 2011 SBS. Has anyone else experienced this before? What can be done?

    Read the article

  • Problems migrating software RAID 5 to new server (linux)

    - by leleu
    I have a CentOS setup with sw RAID5 that holds my data. Well, the server died, so I bought another box to migrate my drives to. Only thing is, I cannot get the RAID array rebuilt (not even sure it needs rebuilding, might just need the /dev/md0 mapping created... but I don't even know how to determine what I need!) Some details: RAID5 software (used mdadm) 4x 250GB drives (2 are SATA, 2 are EIDE -- would this matter? It worked fine in the other box...) latest CentOS distro built using mdadm I've got a decent amount of experience with standard linux stuff, but the hardware level stuff runs me in circles. I've spent some time googling and elsewhere here on SF, so please be kind for my newbie questions :). My question is this: how can I diagnose the problem? For all I know, I'm using the wrong device blocks when I try to rebuild the array, but I can't find the command to display only the devices that have some physical attachment. Is there some simple way for me to run mdadm, having it scan over all my physical drives, and say "hey, drives 2,5,6,7 are a software array, want me to mount it?" I basically just took the drives from my old box and put it into my new one. They show up in the BIOS. What steps do I need to take in order to get the array up, running, and mounted? Thanks in advance!

    Read the article

  • Resize a RAID 1 volume on OSX Snow Leopard - how? (Note: software raid)

    - by Emmel
    I've scoured the Internet in search of an answer to this question, and as usual with OSX-related topics, I often don't find any deep-dive technical explanations sufficient enough to feel confident doing dangerous things. Here is my question: I have a Mac Pro, running OSX 10.6.2. I have, as my main root/boot disk, a RAID 1 volume called "Mirror1". Mirror1 is comprised of two 1 TB disks. Mirror1, however, is fixed at 640 GB. That's because, I originally took a 640GB disk, bought a terabyte disk, mirrored it (using diskutil appleraid enable...), when it synced I removed the 640GB and replaced it with a second 1 TB disk, and synced again. Voila! A single 640 GB replaced by two 1 TB disks in a mirror.. Actually, no. There's still something missing from the equation: Mirror1 needs to be expanded from 640GB to 1 TB to match the partition sizes on each of those disks. How do I do this? Perhaps the diskutil output will help: -> diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk0 1: EFI 209.7 MB disk0s1 2: Apple_RAID 999.9 GB disk0s2 3: Apple_Boot Boot OSX 134.2 MB disk0s3 /dev/disk1 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk1 1: EFI 209.7 MB disk1s1 2: Apple_RAID 999.9 GB disk1s2 3: Apple_Boot Boot OSX 134.2 MB disk1s3 /dev/disk2 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *640.1 GB disk2 1: EFI 209.7 MB disk2s1 2: Apple_HFS Mac Disk 2 536.7 GB disk2s2 3: Microsoft Basic Data BOOTCAMP 103.1 GB disk2s3 /dev/disk3 #: TYPE NAME SIZE IDENTIFIER 0: Apple_HFS Mirror1 *639.8 GB disk3 -> diskutil appleraid list AppleRAID sets (1 found) =============================================================================== Name: Macintosh HD Unique ID: 1953F864-B474-4EB6-8E69-41834EBD0247 Type: Mirror Status: Online Size: 639.8 GB (639791038464 Bytes) Rebuild: manual Device Node: disk3 ------------------------------------------------------------------------------- # Device Node UUID Status ------------------------------------------------------------------------------- 0 disk1s2 25109BAE-5697-40EA-B612-0217851444F7 Online 1 disk0s2 11B83AB0-8148-4DB6-8761-DEF08C855F8D Online =============================================================================== Thanks in advance.

    Read the article

  • Formula to calculate probability of unrecoverable read error during RAID rebuild

    - by OlafM
    I need to compare the reliability of different RAID systems with either consumer or enterprise drives. The formula to have the probability of success of a rebuild, ignoring mechanical problems, is simple: error_probability = 1 - (1-per_bit_error_rate)^bit_read and with 3 TB drives I get 38% probability to experience an URE (unrecoverable read error) for a 2+1 disks RAID5 (4.7% for enterprise drives) 21% for a RAID1 (2.4% for enterprise drives) 51% probability of error during recovery for the 3+1 RAID5 often used by users of SOHO products like Synologys. Most people don't know about this. Calculating the error for single disk tolerance is easy, my question concerns systems tolerant to multiple disks failures (RAID6/Z2, RAIDZ3 and RAID1 with multiple disks). If only the first disk is used for rebuild and the second one is read again from the beginning in case or an URE, then the error probability is the one calculated above squared (14.5% for consumer RAID5 2+1, 4.5% for consumer RAID1 1+2). However, I suppose (at least in ZFS that has full checksums!) that the second parity/available disk is read only where needed, meaning that only few sectors are needed: how many UREs can possibly happen in the first disk? not many, otherwise the error probability for single-disk tolerance systems would skyrocket even more than I calculated. If I'm correct, a second parity disk would practically lower the risk to extremely low values. Am I correct?

    Read the article

  • How to choose the most optimal RAID settings on PE2950

    - by javano
    I have some Dell PowerEdge 2950's with 4x 15k, 150GB Cheetah SAS drives in them. They are going to be VM hosts, CentOS running ESXi with Windows Server 2k8 guests. Some guests will be hosting IIS servers, and others MSSQL servers. I am trying to set the RAID virtual disks settings and can't decide which is more optimal given this situation; Read Policy: Out of Read-Ahead, No-Read-Ahead and Adaptive Read-Ahead, the default is Read-Ahead. I will be making large sequential writes initially, writing out blank images for virtual machine hard drives (lets say 30GBs from /dev/zero for example) so Read-Ahead seems good at first. But within the virtual machines reads could be random from anywhere within their file systems as they are IIS and MSSQL servers, so perhaps No-Read-Ahead is a better idea? Now I think Adaptive Read-Ahead would be better then as a compromise but I don't know much about this option, how does it compare in performance to the others? Write Policy: write-back caching, write-through caching, the default is write-back caching. The default of write-back caching is safer than write-through caching but at a performance expense. My thinking here is that in the event of power loss for example, it seems more likely in my head (this is why I need some clarification!) that damage will occur to a guest VM with write-back caching enabled, so I should favour write-through? I have searched around and there is obviously no definitive answer, so I would like to find out what is best for my situation.

    Read the article

  • Resize a RAID 1 volume on OS X Snow Leopard - how? (Note: software raid)

    - by Emmel
    I've scoured the Internet in search of an answer to this question, and as usual with OSX-related topics, I often don't find any deep-dive technical explanations sufficient enough to feel confident doing dangerous things. Here is my question: I have a Mac Pro, running OS X 10.6.2. I have, as my main root/boot disk, a RAID 1 volume called "Mirror1". Mirror1 is comprised of two 1 TB disks. Mirror1, however, is fixed at 640 GB. That's because, I originally took a 640GB disk, bought a terabyte disk, mirrored it (using diskutil appleraid enable), when it synced I removed the 640GB and replaced it with a second 1 TB disk, and synced again. Voila! A single 640 GB replaced by two 1 TB disks in a mirror.. Actually, no. There's still something missing from the equation: Mirror1 needs to be expanded from 640GB to 1 TB to match the partition sizes on each of those disks. How do I do this? Perhaps the diskutil output will help: -> diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk0 1: EFI 209.7 MB disk0s1 2: Apple_RAID 999.9 GB disk0s2 3: Apple_Boot Boot OSX 134.2 MB disk0s3 /dev/disk1 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk1 1: EFI 209.7 MB disk1s1 2: Apple_RAID 999.9 GB disk1s2 3: Apple_Boot Boot OSX 134.2 MB disk1s3 /dev/disk2 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *640.1 GB disk2 1: EFI 209.7 MB disk2s1 2: Apple_HFS Mac Disk 2 536.7 GB disk2s2 3: Microsoft Basic Data BOOTCAMP 103.1 GB disk2s3 /dev/disk3 #: TYPE NAME SIZE IDENTIFIER 0: Apple_HFS Mirror1 *639.8 GB disk3 -> diskutil appleraid list AppleRAID sets (1 found) =============================================================================== Name: Macintosh HD Unique ID: 1953F864-B474-4EB6-8E69-41834EBD0247 Type: Mirror Status: Online Size: 639.8 GB (639791038464 Bytes) Rebuild: manual Device Node: disk3 ------------------------------------------------------------------------------- # Device Node UUID Status ------------------------------------------------------------------------------- 0 disk1s2 25109BAE-5697-40EA-B612-0217851444F7 Online 1 disk0s2 11B83AB0-8148-4DB6-8761-DEF08C855F8D Online =============================================================================== Thanks in advance.

    Read the article

  • effective back-up using Raid / Win7 back-up

    - by Job
    I have a stand-alone pc system with two 2 tb harddiscs, one of which configured as Raid1, i.e. mirorring. The operational drive is partitioned. I use an external 1 tb harddisc for back-up using Windows 7 back-up facility which will be swapped weekly and stored on other premises. I back-up all partitions AND allow a system back-up. All application software is on the C: partition. Questions: How can I see whether Raid1 is working; i.e. is doing its job. All I see now is a status message in the start-up procedure that says its status is normal. How can I see used or available space on Raid 1? The Win-7 backup allows for 1 schedule only as far as I can see. I want daily back-ups of data. However due to the single schedule I am forced to do the time-consuming system back-up and c: back-up as well. Is there a way to activate two schedules allowing a frequent (daily) data back-up and a system back-up with c: drive back-up on a say weekly basis? Of course it can be forced by hand but I am likely to forget that. I am not the programming type of person so looking for simple and controllable solutions. Thank you - any help is apreciated.

    Read the article

  • mkfs Operation Takes Very Long on Linux Software Raid 5

    - by Elmar Weber
    I've set-up a Linux software raid level 5 consisting of 4 * 2 TB disks. The disk array was created with a 64k stripe size and no other configuration parameters. After the initial rebuild I tried to create a filesystem and this step takes very long (about half an hour or more). I tried to create an xfs and ext3 filesystem, both took a long time, with mkfs.ext3 I observed the following behaviour, which might be helpful: writing inode tables runs fast until it reaches 1053 (~ 1 second), then it writes about 50, waits for two seconds, then the next 50 are written (according to the console display) when I try to cancel the operation with Control+C it hangs for half a minute before it is really canceled The performance of the disks individually is very good, I've run bonnie++ on each one separately with write / read values of around 95 / 110MB/s. Even when I run bonnie++ on every drive in parallel the values are only reduced by about 10 MB. So I'm excluding hardware / I/O scheduling in general as a problem source. I tried different configuration parameters for stripe_cache_size and readahead size without success, but I don't think they are that relevant for the file system creation operation. The server details: Linux server 2.6.35-27-generic #48-Ubuntu SMP x86_64 GNU/Linux mdadm - v2.6.7.1 Does anyone has a suggestion on how to further debug this?

    Read the article

  • Resize a RAID 1 volume on OSX Snow Leopard - how? (Note: software raid)

    - by Emmel
    I've scoured the Internet in search of an answer to this question, and as usual with OSX-related topics, I often don't find any deep-dive technical explanations sufficient enough to feel confident doing dangerous things. Here is my question: I have a Mac Pro, running OSX 10.6.2. I have, as my main root/boot disk, a RAID 1 volume called "Mirror1". Mirror1 is comprised of two 1 TB disks. Mirror1, however, is fixed at 640 GB. That's because, I originally took a 640GB disk, bought a terabyte disk, mirrored it (using diskutil appleraid enable...), when it synced I removed the 640GB and replaced it with a second 1 TB disk, and synced again. Voila! A single 640 GB replaced by two 1 TB disks in a mirror.. Actually, no. There's still something missing from the equation: Mirror1 needs to be expanded from 640GB to 1 TB to match the partition sizes on each of those disks. How do I do this? Perhaps the diskutil output will help: -> diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk0 1: EFI 209.7 MB disk0s1 2: Apple_RAID 999.9 GB disk0s2 3: Apple_Boot Boot OSX 134.2 MB disk0s3 /dev/disk1 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk1 1: EFI 209.7 MB disk1s1 2: Apple_RAID 999.9 GB disk1s2 3: Apple_Boot Boot OSX 134.2 MB disk1s3 /dev/disk2 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *640.1 GB disk2 1: EFI 209.7 MB disk2s1 2: Apple_HFS Mac Disk 2 536.7 GB disk2s2 3: Microsoft Basic Data BOOTCAMP 103.1 GB disk2s3 /dev/disk3 #: TYPE NAME SIZE IDENTIFIER 0: Apple_HFS Mirror1 *639.8 GB disk3 -> diskutil appleraid list AppleRAID sets (1 found) =============================================================================== Name: Macintosh HD Unique ID: 1953F864-B474-4EB6-8E69-41834EBD0247 Type: Mirror Status: Online Size: 639.8 GB (639791038464 Bytes) Rebuild: manual Device Node: disk3 ------------------------------------------------------------------------------- # Device Node UUID Status ------------------------------------------------------------------------------- 0 disk1s2 25109BAE-5697-40EA-B612-0217851444F7 Online 1 disk0s2 11B83AB0-8148-4DB6-8761-DEF08C855F8D Online =============================================================================== Thanks in advance.

    Read the article

  • How can I make my PCI-E graphics card visible to Ubuntu when the motherboard has integrated graphics

    - by Norman Ramsey
    I have a Gigabyte GA-MA74GM-S2 motherboard with integrated graphics that shows up on lspci as an ATI Radeon 2100. I also bought a PCI-Express Nvidia graphics card so I could use the VDPAU feature on Linux (plays H.264 in hardware). The BIOS has three settings about which display to initialize first: Integrated graphics PCI graphics PCI-Express graphics (PEG) I set the BIOS on PEG, but I cannot get anything, not even a splash screen or POST messages, to emerge from the PCI-Express graphics card. (I'm using a DVI connector; the card also has an HDMI output.) I cannot get the kernel lspci to see the graphics card; the only VGA controller it acknowledges is the integrated one. Running dmidecode acknowledges the existence of an x16 PCI Express slot, and it says Current usage: Unknown There is an additional BIOS setting called "Internal Graphics Mode" which is normally set to "Auto" which means it is supposed to prefer a PCI Express VGA card. I set it to "Disabled" which now means I'm getting no output at all. I will soon be learning how to do a BIOS reset! Other information: The PCI-E card is a MSI N210-MD512H GeForce 210. This is a fanless card. Although there are no fans to see turning, the heat sink on the PCI-E card is definitely getting hot, so the card is getting some sort of power. It gets all its power from the PCI-E slot; there is no external power connector. The BIOS is an AMI Award BIOS. My question: how can I make the PCI Express graphics card visible to Ubuntu?

    Read the article

  • Lag spikes at full CPU usage, lagy mouse, maybe video card

    - by Roberts
    My PC specs: Motherboard Name - Gigabyte GA-945PL-S3 CPU Type - DualCore Intel Core 2 Duo E4300, 1800 MHz (9 x 200) OS - Microsoft Windows 7 Ultimate OS Kernel Type - 32-bit OS Version - 6.1.7601 I bougth a new video card one month ago. GeForce 210. I didn't have any problems. I wanted to overclock it, in other words: "Play with it". So I installed Gigabyte EasyBoost from CD and overclocked the GPU 590 + 110 mhz, memory to max to 960mhz from 800mhz. Benchmarks showed a little bit bigger score. Then I overclocked shader clock from 1405 to [..] (don't remeber really). So I was playing Modern Warfare 2 when off sudden computer froze when I wanted to select team, I was afk before that. I had to reset CMOS. After that I had problems with Skype: unread messages and no sound. Then I figured it out that when ever I open EasyBoost - Skype starts to glitch again. Now I use EVGA Precission X. Now after a month, I cleaned computer and closed the case, it was open all the time. I started to overclock GPU clock only (just a bit) because there was no problems that would stop me. So sometimes on heavy CPU load graphics starts to lag. Dragging a window is painful to watch too. Sometimes the screen freezes for 5 to 10 seconds (I can see that hard disk activity is maximal). You may say that CPU fault it is, isn't it? But sometimes lag spikes starts randomly when CPU load is at maximum. All 3 benchmark softwares (PerformanceTest, NovaBench and MSI Kombustor) shows that performance of my video card has dropped about 25%. BUT! CPU score is lower too. I ignored these problems but when I refreshed Windows Experience Index I was shocked. Month before (in latvian language but not so hard to understand): Now 01.04.2012 (upgraded RAM): This happened when I tried to capture Minecraft with Fraps on underclocked GPU to 580mhz (def: 590mhz): All drivers are up to date. Average CPU temperature from 55°C to 75°C (at 70°C sometimes starts these lag spikes). Video card's tempratures are from 45°C to 60°C (very hard to reach 60°C). So my hope is that the video card is fine, cause this card is very new and I want to upgrade CPU anyways. Aplogies for my mistakes in vocabulary (I am trying to type this as fast I can). Update 02.04.2012 - 7:21 Forgot one thing, my hard disk is extrimly slow and I will upgrade it this week or next week so I will be installing same OS again. I am multi-tasker but I can't do much because of 1.8 GHz CPU and slow hard drive (Model ID - WDC WD800JD-60JRC0). The Windows Experience Index is back to normal. Actually "Spelu grafika" (Gaming graphics) are higher than month ago. During this test mouse was very lagy, but month ago there weren't any problems. WHY!?

    Read the article

  • IBM x260m won't boot from PCI SATA card

    - by syrenity
    Hi. We ghosted our old Windows 2003 drive to a new 1TB one, and connected through new PCI SATA card. The x260m server fails to boot with error 1962: "Boot sector not found." When we connect the drive directly to motherboard, it boots fine, so the problem is probably in getting BIOS to boot from the SATA card. Has anyone encountered and solved such issue? EDIT: We tried disabling the on-board Sata controller (Hostraid/SAS?), but there is no such option - only enable, enhanced and compatible. Tried also to chance boot device priority to all possible choices - no luck. Thanks in advance!

    Read the article

  • Storing credit card details

    - by Andrew
    I have a business requirement that forces me to store a customer's full credit card details (number, name, expiry date, CVV2) for a short period of time. Rationale: If a customer calls to order a product and their credit card is declined on the spot you are likely to lose the sale. If you take their details, thank them for the transaction and then find that the card is declined, you can phone them back and they are more likely to find another way of paying for the product. If the credit card is accepted you clear the details from the order. I cannot change this. The existing system stores the credit card details in clear text, and in the new system I am building to replace this I am clearly not going to replicate this! My question, then, is how I can securely store a credit card for a short period of time. I obviously want some kind of encryption, but what's the best way to do this? Environment: C#, WinForms, SQL-Server.

    Read the article

  • How is 'processing credit card data' defined (PCI)?

    - by Chris
    If i have a web application and i receive credit card data transmitted via a POST request by a web browser over HTTPS and instantly open a socket (SSL) to a remote PCI compilant card processor to forward the data and wait for a response, am i allowed to do that? or is this receiving the data with my application and forwarding it already subject of "processing credit card data"? if i create an iframe that is displayed in a client browser to enter cc data and this iframe posts the data via HTTPS to remote card processor (directly!) is this already a case of processing credit card data? even if my application code 'doesnt touch' the entered data with any event handlers? i'm interested in the definition "credit card data processing". when does it start to be a cc data processing application? can somebody maybe point me to that section in PCI-DSS standard that clearly defines when you start to 'be a processing application'? Thanks,

    Read the article

  • What does "single-bit ECC errors were detected on the RAID controller" mean?

    - by jsp
    I have a Dell T7600 with a Perc H710P RAID controller and 4 attached 3TB drives. Over the past few months the RAID controller has been intermittently reporting errors on boot: "no boot device found", "adapter at baseport is not responding", disks frequently reported as missing or failed. I have since replaced the RAID controller, the 4 hard drives, and finally the system's motherboard. After replacing the motherboard and rebooting a few times, I got the error Single bit ECC errors were detected on the RAID controller. Please contact technical support to resolve this issue. After rebooting about 20 more times, I haven't seen the ECC error. The system seems otherwise OK, except for the fact that the disk fans will sometimes start blowing at full blast when the the system is sitting completely idle and not stop until I reboot. Are the ECC errors in memory on the RAID controller? Or, does the RAID controller map in system memory, and the ECC errors are really in system memory? Or, are the ECC errors in the 1GB cache that resides in the RAID controller?

    Read the article

  • Dell Poweredge 1950 with Perc 5i keeps losing raid config -> "Foreign Configuration Found"

    - by nosage
    The quick and dirty: the machine is a Dell Poweredge 1950, dual xeon quad cores, 8GB of ram, 2 2TB seagate SATAs in (supposed to be raid1) using a Perc 5i raid card. They are hot-swappable with a back-plane. I can build the raid fine and after a little while an install of server 08 r2 will blue screen and restart. When it comes up the raid controller says "Foreign Configuration Found." When I go into the raid configuration panel there is no raid listed but I can import the "foreign config", and the OS will boot up fine, until it blue screens again after a little while. The issue is OS independent. I have tried swapping raid cards, swapping the RAM module on the raid card and swapping the raid battery, all to no avail. Its almost as if there is a loose connection from the raid card to the back plane and both of disks get lost and the raid card drops the config. But it sees the disks fine when it boots back up. The raid card uses a SCSI SAS cable to connect to the back-plane so I guess the next step is to replace that, but... then I might as well replace the back-plane with a SCSI SAS to sata breakout cable, but... then I need a way to power the disks. Sorry for the wall of txt but it would be great to get some thoughts from people who worked with perc raid cards or poweredge servers with this type of issue before. Ironically I want to get this system up and running so I can work on MCITP labs. Thank you for any/all help and feel free to ask questions!

    Read the article

  • CentOS - mdadm raid1 drive won't mount to default location

    - by danny
    I'm running CentOS 5.5, the system, boot, swap, etc. is all on /dev/sda and I have two identical single-partition drives /dev/sdb1 /dev/sdc1 that are configured in RAID1 (using mdadm). It was working fine (configured to mount to /mnt/data in the fstab file) and I recently let yum install a couple of automatic updates without paying attention to what they were, and now it doesn't work. Raid is working fine (dmesg shows it gets loaded correctly). mdstat shows: # cat /proc/mdstat Personalities : [raid1] md0 : active raid1 sdc1[1] sdb1[0] XXXX blocks [2/2] [UU] unused devices: <none> Additionally, I can mount it anywhere other than its default directory (i.e. the following works, and I can read data off the drives). # mount /dev/md0 /mnt/data2 EXT3-fs warning: mounting fs with errors, running e2fsck is recommended But when I run the following I get: # mount -a mount: /dev/sdb1 already mounted or /mnt/data busy It says nothing is mounted when I try to umount /dev/sdb1 or umount /mnt/data, so I assume it's the second of those errors. However, lsof | grep mnt shows nothing. The weird thing is that I can save files in /mnt/data. So something is obviously mounted there, but when I try to umount it I get the error that nothing is mounted. /etc/mtab doesn't mention any of the partitions or files I am trying to work with, and fstab just has that one line I mentioned above that is supposed to mount my raid partition. Again, it was all working fine until I On Google I've found a few things about dmraid interfering with mdadm after an update, but I yum remove'd dmraid and rebooted and it didn't help. I'm really confused and need to get this working to get on with my work!

    Read the article

  • Western Digital My Book not recognized by WD software

    - by Kari
    A few years ago I bought a WD My Book Pro 2. It worked fine for a while, then one of the drives failed and I sent it back to be replaced under warranty. I never got around to setting up the new one when I got it back. I finally ran out of room on my internal drive, so I tried to use the external - no go. Both drives spin up, but aren't recognized by either Disk Utility (Mac) or the WD Drive Manager. I tried on a PC as well with fresh software. Then I pulled the drives out of the enclosure (warranty is already expired) and plugged them straight into the PC. Both recognized and working 100% in RAID0. BIOS recognizes either disk as functional; Windows only sees them when both are connected due to the RAID which I can't change without the WD software. The drives that were returned to me are the "Green" drives which I've read are NOT recommended for RAID. Is it possible that this is interfering with them reading externally? Any other ideas? My main computer is a laptop so using them internally isn't an option :(

    Read the article

  • Western Digital My Book not recognized by WD software

    - by Kari
    A few years ago I bought a WD My Book Pro 2. It worked fine for a while, then one of the drives failed and I sent it back to be replaced under warranty. I never got around to setting up the new one when I got it back. I finally ran out of room on my internal drive, so I tried to use the external - no go. Both drives spin up, but aren't recognized by either Disk Utility (Mac) or the WD Drive Manager. I tried on a PC as well with fresh software. Then I pulled the drives out of the enclosure (warranty is already expired) and plugged them straight into the PC. Both recognized and working 100% in RAID0. BIOS recognizes either disk as functional; Windows only sees them when both are connected due to the RAID which I can't change without the WD software. The drives that were returned to me are the "Green" drives which I've read are NOT recommended for RAID. Is it possible that this is interfering with them reading externally? Any other ideas? My main computer is a laptop so using them internally isn't an option :(

    Read the article

< Previous Page | 19 20 21 22 23 24 25 26 27 28 29 30  | Next Page >