Search Results

Search found 30701 results on 1229 pages for 'visual studio setup proje'.

Page 233/1229 | < Previous Page | 229 230 231 232 233 234 235 236 237 238 239 240  | Next Page >

  • Windows 7 access denied to executables.. by what?

    - by stijn
    Ever since I started using Windows 7 this problem has been bothering me. From time to time I see similar questions popping up on misc forums, but never did I see an answer. Here are two scenarios that nearly always reproduce it: the explorer way with explorer, navigate to a directory containing at least one exe file go one directory up immediately delete the directory just navigated to yields Folder Acces Denied dialog stating You need permission to perform this action You require permission from Administrators to make changes to this folder, with the buttons try Again and Cancel hitting Try Again never works immediately. Waiting a minute or so and then clickig it again does work note: if in step 2 and waiting a minute or more before going up one directory, the problem does not occur and the folder can be deleted the visual studio way build a project producing an exe file run the executable then close it immediately build the project again (by changing a single character in a source file for example) yields fatal error LNK1168: cannot open /path/to/the.exe for writing note: if in step 2 and waiting a minute or more before building again, the problem does not occur some specs happens both on Windows 7 32 and 64 bit, with VS2008/2010/2011 happens on 3 different machines I do not have a virusscanner of any kind I do have a bunch of services disabled, but nothing that prevents Windows from running normally, UAC is disabled as well happens on any type of disc I always use a user account that is in the Administrators group Obviously both scenarios are very similar and extremely reproducable. So I figured some process must have the file open for some reason, and release it again later. However, using systinternal's handle -a the exe file in question never shows up. (that is the correct way to use handle, right?) So while explorer/VS are reporting they cannot access the file, handle.exe says it's not in use anywhere. This leaves me rather clueless, so I'm wondering if someone can come up with a solution: why does this happen, and how to solve it?

    Read the article

  • MySQL ADO.NET Connector & MSSQL Integration Services

    - by user1114330
    Here I am, day three... attempting to sync a data view on a Windows Vista box (64 bit) running MSSQL 2012 and Visual Studio 2010. Sanity is slipping and hunger for progress fills my attention. I went through hell trying to get the MySQL ODBC drivers to get the job but to no avail...everyone seems to be lost and all the threads I can find are solutions that do not work for me. The problem: System DSN's not being seen by SSIS. SSIS DSN Not Showing as ODBC Data Source I make the decision to try out the ADO.NET connector...and to my surprise it is actually in the selection list in data sources in SSIS. So I take off running to create a Data Flow Task, create an ADO.NET Source (a local MSSQL DB)...all is good as usual. Then I move swiftly to creating a ADO.NET Destination, enter my credentials...wow, I am selecting a database finally on my linux server! Happy thinking that I finally have figured a way to get the job done. Then I move to mappings...nope, something is wrong...I am getting an error that hurts my eyes: Pipeline component has returned HRESULT error code 0xC0208457 from a a method call. Error at Data Flow Task [ADO NET Destination [81]]: Failed to get properties of external columns. The table name you entered may not exist or you do not have SELECT permission on the table object and an alternative attempt to get column properties through connection has failed. Detailed error messages are" You have an error in your SQL syntax check the manual that corresponds to your MySQL server version for the right syntax to use near "database".tablename" at line 1. The descriptor files on path C:\Program Files (x86)\Microsoft SQL Server\110\DTS\ProviderDescriptors\ does not contain schema information for connection of type MySQL.Data.MySqlClient.MySqlConnection. So it looks like it can't the information and therefore I cannot map the tables properly. Any ideas on this would be ultra helpful...thanks in advance to All!

    Read the article

  • Working with an external button box

    - by Scott
    I tried this question on Stack Overflow, but I was pointed here, so here goes: For a new project for myself, I am looking for a way to be able to (for example) open a pop-up window on my laptop, by pressing a button on an external device (to be build by myself, or at least bought) connected with USB. Basically I would be looking at something like a Arduino or Raspberry (IF I am looking in the right direction) with buttons on it, and as soon as I hit a button on the external box with physical buttons, a command activates on my laptop and for example opens a popup window in which I can input tekst. Does anyone know: 1) if it is possible to do this at all. 2) What equipment is needed for the external box, what programming is needed. I preffer .net (dot net) but maybe it can only be done with software from the external box. If anyone can point me in the right direction, like make/model of the external box or websites I would be very happy. I have knowledge of Visual Studio/.net but I am willing to learn other languages if .net is not an option for this project. Thanks in advance Scott PS: If anyone knows of some better tags, or at least knows what I mean and needs me to edit the question, please do tell me... I am new on Stack Overflow/Superuser.

    Read the article

  • How to deploy a visual studio custom tool?

    - by Aen Sidhe
    Hello. I have a my own custom tool for Visual Studio 2008 SP1. It consists of 5 assemblies: 3 assemblies with code that used heavily in my other projects, 1 assembly-wrapper above VS2008 SDK and assembly with the tool. If I'd debug my tool from visual studio, using "Run external program" option with command line "C:\Program Files (x86)\Microsoft Visual Studio 9.0\Common7\IDE\devenv.exe" and arguments "/ranu /rootsuffix Exp" all work perfectly. After that I trying to deploy it to my working VS copy, not to experimental hive doing: gacutil /i Asm1.dll for all my assemblies and doing RegAsm Asm1.dll only for assembly with custom tool. Neither of utils prints any error, all work as planned, even registry keys appeared. But my tool don't work even after PC restart. What did I do wrong? Wrapper looks like that: [ComVisible(true)] public abstract class CustomToolBase : IVsSingleFileGenerator, IObjectWithSite { #region IVsSingleFileGenerator Members int IVsSingleFileGenerator.DefaultExtension(out string pbstrDefaultExtension) { pbstrDefaultExtension = ".cs"; return 0; } int IVsSingleFileGenerator.Generate(string wszInputFilePath, string bstrInputFileContents, string wszDefaultNamespace, IntPtr[] rgbOutputFileContents, out uint pcbOutput, IVsGeneratorProgress pGenerateProgress) { GenerationEventArgs gea = new GenerationEventArgs( bstrInputFileContents, wszInputFilePath, wszDefaultNamespace, new ServiceProvider(Site as Microsoft.VisualStudio.OLE.Interop.IServiceProvider) .GetService(typeof(ProjectItem)) as ProjectItem, new GenerationProgressFacade(pGenerateProgress) ); if (OnGenerateCode != null) { OnGenerateCode(this, gea); } byte[] bytes = gea.GetOutputCodeBytes(); int outputLength = bytes.Length; rgbOutputFileContents[0] = Marshal.AllocCoTaskMem(outputLength); Marshal.Copy(bytes, 0, rgbOutputFileContents[0], outputLength); pcbOutput = (uint)outputLength; return VSConstants.S_OK; } #endregion #region IObjectWithSite Members void IObjectWithSite.GetSite(ref Guid riid, out IntPtr ppvSite) { IntPtr pUnk = Marshal.GetIUnknownForObject(Site); IntPtr intPointer = IntPtr.Zero; Marshal.QueryInterface(pUnk, ref riid, out intPointer); ppvSite = intPointer; } void IObjectWithSite.SetSite(object pUnkSite) { Site = pUnkSite; } #endregion #region Public Members public object Site { get; private set; } public event EventHandler<GenerationEventArgs> OnGenerateCode; [ComRegisterFunction] public static void Register(Type type) { using (var parent = Registry.LocalMachine.OpenSubKey(@"Software\Microsoft\VisualStudio\9.0", true)) foreach (CustomToolRegistrationAttribute ourData in type.GetCustomAttributes(typeof(CustomToolRegistrationAttribute), false)) ourData.Register(x => parent.CreateSubKey(x), (x, name, value) => x.SetValue(name, value)); } [ComUnregisterFunction] public static void Unregister(Type type) { using (var parent = Registry.LocalMachine.OpenSubKey(@"Software\Microsoft\VisualStudio\9.0", true)) foreach (CustomToolRegistrationAttribute ourData in type.GetCustomAttributes(typeof(CustomToolRegistrationAttribute), false)) ourData.Unregister(x => parent.DeleteSubKey(x, false)); } #endregion } My tool code: [ComVisible(true)] [Guid("55A6C192-D29F-4e22-84DA-DBAF314ED5C3")] [CustomToolRegistration(ToolName, typeof(TransportGeneratorTool))] [ProvideObject(typeof(TransportGeneratorTool))] public class TransportGeneratorTool : CustomToolBase { private const string ToolName = "TransportGeneratorTool"; public TransportGeneratorTool() { OnGenerateCode += GenerateCode; } private static void GenerateCode(object s, GenerationEventArgs e) { try { var serializer = new XmlSerializer(typeof (Parser.System)); using (var reader = new StringReader(e.InputText)) using (var writer = new StringWriter(e.OutputCode)) { Generator.System = (Parser.System) serializer.Deserialize(reader); Generator.System.Namespace = e.Namespace; Generator.GenerateSource(writer); } } catch (Exception ex) { e.Progress.GenerateError(ex.ToString()); } } } Resulting registry keys: Windows Registry Editor Version 5.00 [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\VisualStudio\9.0\Generators] [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\VisualStudio\9.0\Generators\{FAE04EC1-301F-11D3-BF4B-00C04F79EFBC}] [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\VisualStudio\9.0\Generators\{FAE04EC1-301F-11D3-BF4B-00C04F79EFBC}\TransportGeneratorTool] @="TransportGeneratorTool" "CLSID"="{55a6c192-d29f-4e22-84da-dbaf314ed5c3}" "GeneratesDesignTimeSource"=dword:00000001 "GeneratesSharedDesignTimeSource"=dword:00000001

    Read the article

  • How can i add a checkbox for optional files during install? (innosetup)

    - by Globulorozzo
    i'm trying to make a custom checkbox in my custom page (because is a one page installer), is needed only a checkbox without dialogs or anything, the installer that i'm trying to compile is very linear and simple. i want to bind "FILE3.EXE" on a checkbox in this way: if checkbox is checked copy the file (FILE3.EXE) in DestDir, otherwise if checkbox is unchecked skip the file (FILE3.EXE) during installation. This is the code that i use, obviously the checkbox code is missing because i'm not able to do that [Files] Source: FILE1.EXE; DestDir: {app}; Source: FILE2.EXE; DestDir: {app}; Source: FILE3.EXE; DestDir: {app}; //OPTIONAL [Code] procedure ExitProcess(uExitCode: UINT); external '[email protected] stdcall'; var MainPage : TWizardPage; FolderToInstall : TEdit; InstallLocation : String; procedure CancelClick(Sender: TObject); begin if ExitSetupMsgBox then begin ExitProcess(0); end; end; procedure BrowseClick(Sender : TObject); var Dir : String; begin Dir := FolderToInstall.Text; if BrowseForFolder('Browse',Dir,false) then FolderToInstall.Text := Dir; WizardForm.DirEdit.Text := Dir; end; procedure InitializeWizard(); var LabelFolder : TLabel; begin WizardForm.ClientWidth:=ScaleX(550); WizardForm.ClientHeight:=ScaleY(250); WizardForm.Center; WizardForm.OuterNotebook.Hide; WizardForm.InnerNotebook.Hide; WizardForm.Bevel.hide; Wizardform.NextButton.top := 180; Wizardform.NextButton.Left := 470; WizardForm.NextButton.Height := 25; WizardForm.StatusLabel.Parent := WizardForm; WizardForm.StatusLabel.Left := 6; WizardForm.StatusLabel.Top := 206; WizardForm.FilenameLabel.Parent := WizardForm; WizardForm.FilenameLabel.Left := 87; WizardForm.FilenameLabel.Top := 206; WizardForm.FilenameLabel.Width := ScaleX(383); WizardForm.ProgressGauge.Parent := WizardForm; WizardForm.ProgressGauge.Left :=5; WizardForm.ProgressGauge.Top := 222; WizardForm.ProgressGauge.Width := ScaleX(460); MainPage := CreateCustomPage(wpWelcome,'',''); LabelFolder := TLabel.Create(MainPage); LabelFolder.Parent := WizardForm; LabelFolder.Top := 164; LabelFolder.Left := 6; LabelFolder.Caption := 'Directory:' FolderToInstall := TEdit.Create(MainPage); FolderToInstall.Parent := WizardForm; FolderToInstall.Top := 182; FolderToInstall.Left := 85; FolderToInstall.Width := 380; FolderToInstall.Text := WizardDirValue; FolderToInstall.ReadOnly := True; end;

    Read the article

  • warning BC40056: Namespace or type specified in the Imports 'MS.Internal.Xaml.Builtins' doesn't cont

    - by Heinzi
    I have a WPF VB.NET project in Visual Studio 2008. For some reason, Visual Studio thinks that it needs to add an Imports MS.Internal.Xaml.Builtins to every auto-generated XAML partial class (= the nameOfXamlFile.g.vb files), resulting in the following warning: warning BC40056: Namespace or type specified in the Imports 'MS.Internal.Xaml.Builtins' doesn't contain any public member or cannot be found. Make sure the namespace or the type is defined and contains at least one public member. Make sure the imported element name doesn't use any aliases. I can remove the Imports line, but, since this is an auto-generated file, it reappears every time that the project is rebuilt. This warning message is annoying and clutters my error list. Is ther something that can be done about it? Or is it a known bug?

    Read the article

  • Plastic SCM vs. SVN

    - by jon37
    I'm currently researching new source control options for a team of 10 developers. We do .net development in Visual Studio 2008. We currently use VSS for source control. We are looking for a centralized source control solution(non-distributed), with a nice Visual Studio plugin. My manager has recommended Plastic SCM and I've always heard good things about Subversion. I'm trying to decide if we should adopt Subversion or Plastic SCM. There isn't much information out there about Plastic SCM (except what they've written) and I was wondering if it would be a good solution. They make it sound as if branching is much simpler. Subversion on the other hand has a robust, mature community, and it has been thoroughly field tested. What are the pros and cons to these tools? Also are there any other tools that you could suggest? Thanks

    Read the article

  • TFS and shared projects in multiple solutions

    - by David Stratton
    Our .NET team works on projects for our company that fall into distinct categories. Some are internal web apps, some are external (publicly facing) web apps, we also have internal Windows applications for our corporate office users, and Windows Forms apps for our retail locations (stores). Of course, because we hate code reuse, we have a ton of code that is shared among the different applications. Currently we're using SVN as our source control, and we've got our repository laid out like this: - = folder, | = Visual Studio Solution -SVN - Internet | Ourcompany.com | Oursecondcompany.com - Intranet | UniformOrdering website | MessageCenter website - Shared | ErrorLoggingModule | RegularExpressionGenerator | Anti-Xss | OrgChartModule etc... So.. The OurCompany.com solution in the Internet folder would have a website project, and it would also include the ErrorLoggingModule, RegularExpressionGenerator, and Anti-Xss projects from the shared directory. Similarly, our UniformOrdering website solution would have each of these projects included in the solution as well. We prefer to have a project reference to a .dll reference because, first of all, if we need to add or fix a function in the ErrorLoggingModule while working on the OurCompany.com website, it's right there. Also, this allows us to build each solution and see if changes to shared code break any other applications. This should work well on a build server as well if I'm correct. In SVN, there is no problem with this. SVN and Visual Studio aren't tied together in the way TFS's source control is. We never figured out how to work this type of structure in TFS when we were using it, because in TFS, the TFS project was always tied to a Visual Studio Solution. The Source Code repository was a child of the TFS Project, so if we wanted to do this, we had to duplicate the Shared code in each TFS project's source code repository. As my co-worker put it, this "breaks every known best practice about code reuse and simplicity". It was enough of a deal breaker for us that we switched to SVN. Now, however, we're faced with truly fixing our development processes, and the Application Lifecycle Management of TFS is pretty close to exactly what we want, and how we want to work. Our one sticking point is the shared code issue. We're evaluating other commercial and open source solutions, but since we're already paying for TFS with our MSDN Subscriptions, and TFS is pretty much exactly what we want, we'd REALLY like to find a way around this issue. Has anybody else faced this and come up with a solution? If you've seen an article or posting on this that you can share with me, that would help as well. As always, I'm open to answers like "You're looking at it all wrong, bonehead, HERE'S the way it SHOULD be done.

    Read the article

  • WiX: Prevent 32-bit installer from running on 64-bit Windows

    - by Tom the Junglist
    Hi everyone, Due to user confusion, our app requires separate installers for 32-bit and 64-bit versions of Windows. While the 32-bit installer runs fine on win64, it has the potential to create support headaches and we would like to prevent this from happening. I want to prevent the 32-bit MSI installer from running on 64-bit Windows machines. To that end I have the following condition: <Condition Message="You are attempting to run the 32-bit installer on a 64-bit version of Windows."> <![CDATA[Msix64 AND (NOT Win64)]]> </Condition> With the Win64 defined like this: <?if $(var.Platform) = "x64"?> <?define PlatformString = "64-bit"?> <?define Win64 ?> <?else?> <?define PlatformString = "32-bit"?> <?endif?> Thing is, I can't get this check to work right. Either it fires all the time, or none of the time. The goal is to check presence of the run-time msix64 variable against the compile-time Win64 variable and throw an error if these don't line up, but the logic is not working how I intend it to. Has anyone come up with a better solution? Thanks! Tom

    Read the article

  • VS 2010 and Entity Framework: accessing SQL Server 2000 databases

    - by pcampbell
    Consider a Visual Studio 2010 project whose requirement is to model the data using Entity Framework. The datasource is a SQL Server 2000 database. The first step is creating a new ADO.NET Entity Data Model item. The Entity Data Model Wizard prompts for a Data Connection. When creating a new Connection, you will need to use a provider other than SqlClient. Usually it's SQLOLEDB. The list of data providers only has SqlClient or ".NET Framework Data Provider for SQL Server". Is there a work-around for Visual Studio 2010 to create or use data connections to SQL Server 2000 using the Entity Framework?

    Read the article

  • VisualStudio2010 Debugging - The process cannot access the file ... because it is being used by anot

    - by Richard Forss
    I'm unable to debug a WinForms C# application using the released version of Visual Studio 2010 Prof. I get the following error message after the second debugging run. Error 9 Unable to copy file "obj\x86\Debug\Arrowgrass Reports.exe" to "bin\Debug\Arrowgrass Reports.exe". The process cannot access the file 'bin\Debug\Arrowgrass Reports.exe' because it is being used by another process. I've tried a pre-build script to attempt to delete this file, but it's locked by Visual Studio. There are a few references to this on the net so it is a know problem. Does anyone have a hotfix or effective work-around?

    Read the article

  • Will you use Delphi Prism

    - by Mohammed Nasman
    CodeGear announces that their Next .Net product which is known as Delphi Prism Will be RemObjects's Oxygene. Oxygene has many nice features that not found in Delphi or C#, and I think it will be a more effective solution for .Net than Delphi .Net previous releases, but it's uses Visual Studio IDE instead of Delphi IDE. which has some cons and pros. As Delphi Developer or .Net Developer, do you consider to use Delphi Prism for .Net developmenet? Look at these Links for more info. Delphi Prism vs. CSharp Delphi Prism - Visual Studio Pascal For .NET Delphi Prims home page

    Read the article

  • I have made an installer for MyProgram but the uninstall shortcut that it creates leaves behind empt

    - by Coder7862396
    I have created an installer for MyProgram using the Visual Studio Installer (Visual Studio Setup Project). It is called "MyProgram Setup.msi". It installs the program fine and if it is uninstalled using the Add/Remove Programs control panel then everything gets removed as it should. The problem is that I want to add a shortcut to the "User's Programs Menu" under the program shortcut called "Uninstall MyProgram". I have tried doing this in 3 different ways and in all 3 ways if MyProgram is uninstalled using that shortcut, the uninstall will leave behind 2 empty folders ("...Program Files\MyCompany\" and "...Program Files\MyCompany\MyProgram\"). Here are the 3 ways that I have tried to make an uninstaller shortcut: 1) A shortcut to a batch or script file Uninstall MyProgram.bat: @ECHO OFF msiexec /uninstall {MyGUID} Uninstall MyProgram.vbs: Dim objShell Set objShell = WScript.CreateObject("WScript.Shell") objShell.Run("START /B msiexec /uninstall {MyGUID}") Set objShell = Nothing 2) Editing the MSI file using Orca.exe I found out how to do this using this guide: http://www.codeproject.com/KB/install/MSIShortcuts.aspx I added the Shortcut Entry to the Shortcut table. Uninstalling worked but it still left behind the 2 empty folders when using this shortcut. 3) From code within MyProgram.exe I modified MyProgram.exe to take a "/uninstall" command line parameter to run "msiexec.exe /uninstall {MyGUID}" and exit itself. Similar to this solution: http://www.codeproject.com/KB/install/DeployUninstall.aspx None of these attempts created a shortcut which can uninstall the program as well as the program's base folders. I don't want to switch to some other installer product such as Inno Setup, NSIS, or WiX.

    Read the article

  • Outlook 2003 View Control with C#

    - by Eleasar
    I want to embed a custom c# windows form (or WPF) user control into an outlook view. I am using Outlook 2003 and Visual Studio 2008. I did download an example for Outlook 2007 here: http://blogs.msdn.com/e2eblog/archive/2008/01/09/outlook-folder-homepage-hosting-wpf-activex-and-windows-forms-controls.aspx and also here: http://msdn.microsoft.com/en-us/library/aa479345.aspx I tested it and under 2007 it is working, but for 2003 i am getting the following error when i want to open the view: Could not complete the operation due to error 80131509 I can start it from Visual Studio, it is registering the folder just fine, debugging works and all that. It creates an HTML page that contains my type as an object parameter - but the Initialize method that should be called is either not present (not shown via JS) or it has some errors. The breakpoints for RegisterSafeForScripting are also never hit - maybe related to that. Thx in advance!

    Read the article

  • ssh tunneling with visualsvn

    - by DeveloperChris
    I have been asked to setup visualsvn for visual studio 2008 Due to firewall restrictions and server configuration. I need to use ssh tunneling. My problem is this. The local machine needs to connect to a gateway machine via ssh then connect to the subversion server so Local machine ---{ssh}--- gateway ---{ssh}-- subversion server I am not exactly sure of the correct process to do this. It appears that I must start a ssh process using plink to open a local port and forward that to the remote subversion server. eg: plink user@gateway -L 22:192.168.1.1:22 Then when visualsvn starts it uses tortoiseplink to make the actual connection through to the subversion server using svn+ssh://username@localhost:22/myrepo This seems very very clunky. firstly it needs several steps to setup the connection secondly I need plink running which leaves a command prompt on the desktop (clutter = yuck) lastly I need to use two different programs that do the same thing. (plink + tortoiseplink) The problem is that tortoiseplink doesn't run in the background. As soon as I connect to the ssh gateway and enter the password it closes again. So I can't use it to create the initial connection. If I use plink instead of tortoiseplink in visualsvn then I never get prompted for the password. so it just hangs with an open command prompt and no password request. Is there a way to setup visualsvn so that everything happens in one command line? I have searched high and low for a suitable and clean method to tunnel from visualsvn to the remote server and have found very little. it all either assumes one hop (not two like mine) or it glosses over all the hard bits. DC

    Read the article

  • Grails beginner problem "Failed to invoke Servlet 2.5"

    - by A Lion
    I'm trying to get Groovy on Grails set up on a Snow Leopard machine. I followed all the grails.com install directions and am trying to start the application from Grails: A Quick-Start Guide by Dave Klein. I ran grails create-app TekDays with no apparent problems and was able to cd to the TekDays folder, but when I try to run grails run-app I get the following: Welcome to Grails 1.3.1 - http://grails.org/ Licensed under Apache Standard License 2.0 Grails home is set to: /grails Base Directory: /apps/TekDays Resolving dependencies... Dependencies resolved in 4469ms. Running script /grails/scripts/RunApp.groovy Environment set to development [delete] Deleting directory /Users/name/.grails/1.3.1/projects/TekDays/tomcat Running Grails application.. 2010-05-24 21:42:39,559 [main] ERROR context.GrailsContextLoader - Error executing bootstraps: Failed to invoke Servlet 2.5 getContextPath method java.lang.IllegalStateException: Failed to invoke Servlet 2.5 getContextPath method at org.grails.tomcat.TomcatServer.start(TomcatServer.groovy:164) at grails.web.container.EmbeddableServer$start.call(Unknown Source) at _GrailsRun_groovy$_run_closure5_closure12.doCall(_GrailsRun_groovy:159) at _GrailsRun_groovy$_run_closure5_closure12.doCall(_GrailsRun_groovy) at _GrailsSettings_groovy$_run_closure10.doCall(_GrailsSettings_groovy:282) at _GrailsSettings_groovy$_run_closure10.call(_GrailsSettings_groovy) at _GrailsRun_groovy$_run_closure5.doCall(_GrailsRun_groovy:150) at _GrailsRun_groovy$_run_closure5.call(_GrailsRun_groovy) at _GrailsRun_groovy.runInline(_GrailsRun_groovy:116) at _GrailsRun_groovy.this$4$runInline(_GrailsRun_groovy) at _GrailsRun_groovy$_run_closure1.doCall(_GrailsRun_groovy:59) at RunApp$_run_closure1.doCall(RunApp.groovy:33) at gant.Gant$_dispatch_closure5.doCall(Gant.groovy:381) at gant.Gant$_dispatch_closure7.doCall(Gant.groovy:415) at gant.Gant$_dispatch_closure7.doCall(Gant.groovy) at gant.Gant.withBuildListeners(Gant.groovy:427) at gant.Gant.this$2$withBuildListeners(Gant.groovy) at gant.Gant$this$2$withBuildListeners.callCurrent(Unknown Source) at gant.Gant.dispatch(Gant.groovy:415) at gant.Gant.this$2$dispatch(Gant.groovy) at gant.Gant.invokeMethod(Gant.groovy) at gant.Gant.executeTargets(Gant.groovy:590) at gant.Gant.executeTargets(Gant.groovy:589) Caused by: java.lang.NoSuchMethodException: javax.servlet.ServletContext.getContextPath() at java.lang.Class.getMethod(Class.java:1605) ... 23 more I've googled every derivative of "Failed to invoke Servlet 2.5" that I can think of, but have thus far been unable to find anything that helps me understand, yet alone resolve, the error. Any advice to help me resolve this would be very much appreciated!

    Read the article

  • Install .NET 4.0 dll to the GAC

    - by Lucas
    I have a visual C# 2010 express install. Built a .NET 4.0 dll that is signed. Now I need to get it into the GAC. Im on 64bit vista. Anyone know if there is a gacutil supporting the 4.0 framework yet? Any other suggestions on getting it into the GAC? I have tried drag and drop into C:\Windows\assembly, whenever I do, it appears to copy; however, it is not copied and does not produce any error message. I cannot create a setup/deployment project as it appears the express editions of visual studios do not have the ability.

    Read the article

  • Clean conflicting class files from Temporary ASP.NET Files

    - by Deepfreezed
    Class file Conflicts in C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\ is preventing me from building the solution. Even though I try emptying out the folder, each time Visual Studio starts the build process, it brings in the class file in to the temp folder with the same folder name. If I restart the machine or leave it overnight, project build without error. Is there anyway to tell Visual studio to delete/ignore/clean any lingering class files that could be in the temp folder? Clean solution option in VS doesn't work either. Class file in conflict are from the App_Code folder.

    Read the article

  • WCF RIA Services build error

    - by soren.enemaerke
    Hi I'm getting a strange error when building my WCF RIA Services Silverlight project in VS2008. In the output I have this message: C:\Program Files\MSBuild\Microsoft\Silverlight\v3.0\Microsoft.Ria.Client.targets(261,5): error : Failed to write the generated contents of 'C:\projects\[Path_To_Silverlight_Project]\Generated_Code\Analytics.Web.g.cs' to Visual Studio. ...and Visual Studio opens a dialog while building with the following: An editor or project is attempting to save a file that is modified in memory. Saving files during a build is dangerous and may result in incorrect build outputs in the future. Continue with save? The other members on my team seems to be doing just fine, but I can't get past this point (I can if I click 'Continue' which then generate the file just fine but I'm reluclant to do so). There must be some setup or similar that I'm missing here... PS: I'm currently on WinXP and WCF RIA Service beta

    Read the article

  • cannot find vcvarsall.bat when runnning a pyhton script

    - by Ariel
    hello all, i am working on vista, and using python 2.6.4. i am using a software which uses a python script. but then i bumped into the message "cannot find vcvarsall.bat". so i installed visual c++ 2010. still the file is not found though it is there. my guess (a very uneducated one...) is that somewhere the path is wrong, because i also have an old visual 2008 (pretty empty) folder. since i have little idea in programming i have no idea where to make the changes for the new path. do i change something in the registery or in the script. i would be happy if somebody could help (preferably in lamen terms). thanx. Ariel

    Read the article

  • How to set up a Hudson server to run cppunit tests

    - by kyue
    Hello, I'm having problems setting up my Hudson server to run cpp unit tests so I can output an .xml file. I tried searching the web for some more straight forward instructions on how to set this up but still don't understand how to. It sounds like I need to set up ant to run...but how?? I'm currently running Hudson ver 1.352. Any suggestions will be greatly appreciated. Kat

    Read the article

  • Designing a data model in VS2010 and generating ORM code, application

    - by Kay Zed
    Simply put: I have a database design in my head and I now want to use Visual Studio 2010 to create a WPF application. Key is to use the VS2010 tools to take much as possible manual work out of my hands. -The database engine is SQLite -ORM probably through DBLINQ -Use of LINQ -The application can create new, empty database instances -Easily maintainable (changes in data model possible) Q- How do I start designing the database model (visually) in Visual Studio 2010? Should this be an xsd? Do I do this in a separate project? Q- Next, how can I make the most use of VS2010 code generation tools to generate a business layer? Q- I suppose the business layer will be added as a Data Source (in another project?) and from there it's a rather generic data binding solution? I tried finding clear examples of this but it's a jungle out there, the hunt for a solution is NOT converging to one clear method.... :_(

    Read the article

  • VisualStudio 2010 Settings Page - Collection Settings

    - by Ed Eichman
    I have a list of Filemaker database names Each DB name has a list of field/attribute pairs associated with it I have a windows form application in C# 4.0 (vs2010) that wants to use the above data I would like to maintain the list either in the Visual Studio settings page, or in one of the standard visual studio settings files using the standard .NET settings calls I would like to avoid writing my own custom settings, xml, xds (to avoid the "Could not find schema information for the element/attribute " errors) I just have a slightly complicated INI file! I don't want to complicate my life! Do any easy solutions exist? Unless someone has a brighter idea, I am simply going to write string settings with names that indicate it's a FM DB (e.g. "fmdbAddresses"), and values that concat my field/attribute pairs (e.g. "gUserResult=skipField|gAddressID=convertToInt|gAddressID=uniqueIx")

    Read the article

< Previous Page | 229 230 231 232 233 234 235 236 237 238 239 240  | Next Page >