Search Results

Search found 25718 results on 1029 pages for 'external hard drive'.

Page 239/1029 | < Previous Page | 235 236 237 238 239 240 241 242 243 244 245 246  | Next Page >

  • Partial Evaluation of ConstantExpression in ExpressionTreeVisitor

    - by Andrew Theken
    Hi all, I am not an Expression Tree master by any stretch of the imagination, what I have is code that looks like this: int external = 10; using(var session = new Session()) { session.Add(new Product { Name = "test1", Price = 20 }); session.Add(new Product {Name = "test", Price = 10}); var product = session.Products.Where(p => p.Price == external).FirstOrDefault(); Assert.Equal(10, product.Price); } Session implements all the IQueryProvider, IQueryable interfaces you'd come to expect from a LINQ Provider. When I execute the query, everything goes to plan until I read the ConstantExpression for "external", at which point, I am at a loss as to how to move forward because: //constant is ConstantExpression for "external" on the right side of the "p.Price == external" expression above. var t = constant.GetType(); //evaluates to class called "<>c__DisplayClass2" - with a member named "external" that has the value 10. The question is basically.. How can I just access the value of the member "external" - is there a way to accomplish this without using reflection? or am I cooked? What am I missing?

    Read the article

  • Very weird C file-handling anomaly

    - by KáGé
    Hello, I got a very weird issue that I cant figure out in my school project, which is the simulation of a simple filesystem in a human-readable textfile. Unfortunately I don't yet have enough time to translate the comments in my code or make it less gibberish, so if you are bothered by that, you don't have to help, I understand. See the code HERE. Now in drive.h, at line 574 is this part: i = getline(); #ifdef DEBUG printf("Free space in all found at %d.\n\n", i); if(drive.disk != NULL){ printf("Disk OK\n\n"); } #endif //write in data state = seekline(i); Before this it finds place for the allocation database entry in the ALL sector (see the "image files" in the mounts folder, this issue was tested on mount_30.efs-dbf), then gets the line with i = getline() fine (getline is in lglobal.h, line 39), but after that any file manipulation (in this case seekline's fseek, but if I comment that out, then the first fprintf after that) crashes the program straight away. I think the file gets somehow corrupted (though the Disk OK message appears) but can't figure out how. I've tried putting i = getline(); into comment, but it didn't make any difference. I've also tried asking at local programming forums but they didn't really help either. The last few lines of the output before it crashes: Dir written. (drive.h line 562) Seekline entered: 268 (called at drive.h line 564) Getline entered. (called at drive.h line 574) Line got: 268. Free space in all found at 268. (drive.h line 576) Seekline entered: 268 (called at drive.h line 582, note that this exact call was run successfully less than 20 lines back. This one should set the pointer to the beginning of the line it is currently in) After this it crashes. Does anyone has any idea of what causes this and how could I fix it? Thank you.

    Read the article

  • How can I specify dependencies in the manifest file and then to include it into my .jar file?

    - by Roman
    I generated .class files by the following command: javac -cp \directoryName\external.jar myPackageDirectory\First.java myPackageDirectory\Second.java I needed to use -cp during compilation and name of .jar file of an "external" library (external.jar) to be able to use this library from my code. Using my .class files I have generated my .jar file in the following way: jar cfm app.jar manifest.txt myPackageDirectory\*.class manifest.txt contains just one line: Main-Class: myPackageName.First My problem is that I am not sure that I will be able to run my .jar file on other computers. I think so because during the compilation I specified the location of the .jar file of the external library. So, my .class files (included into the .jar file will try to find the .jar file of the external library in a specific directory and there is no guaranty that that the .jar file of the external library will be in the same directory as on the my computer. I heard that the above problem can be solved by a usage of a MANIFEST file that I include in my own jar, and which will list dependency locations but I do not understand how it works. I do need to specify location of the "external.jar" at the compilation stage (otherwise the compiler complains).

    Read the article

  • Rebuilding array on 3ware 9690SA-8I

    - by Tim Jones
    I have a RAID10 (8x1TB) array on a 3ware 9690 card running on an Ubuntu 1110 server. There was a kernel update so I scheduled a reboot after which the array was inaccessible. I checked the status a drive has died in the array, but the controller has thrown the entire array into an 'inoperable' state instead of simply degraded (what's the point of the RAID now ;-). After taking out the 'dead' drive I run a quick test to find it completely functional without a bad sector to be found. I try to put the drive back in but the array still marks the disk as degraded (remembering serial number or something??) and the entire array as inoperable... So I swap it out for a known working drive (not the same capacity but higher - should still work) and initiate a rebuild with the the new drive as a replacement. This fails instantly with the error "(0x0B:0x0033): Unit busy : Failed to start Rebuild on Unit 0". The unit shouldn't be busy as it is not mounted (the card itself is listed with lshw but the array it provides is not). I'm pretty much at an impasse now, I don't understand how I can have a single drive failure on a RAID10 that makes the entire array inaccessible, degraded I could understand but inaccessible?? I don't think the controller as prior to the reboot it was completely functional.

    Read the article

  • Problem booting virtual machine after converting VMDK to VHD

    - by vg1890
    I used the VMWare VCenter Converter Standalone Client to convert a physical drive on my old PC to a virtual drive. The conversion worked fine and I ended up with a valid VMDK file. Next, I wanted to convert the VMDK to a VHD for use with Microsoft Virtual PC, since that's what I use on my new box. I used WinImage for the conversion and that worked fine, too. I can access the files from the virtual drive through WinImage. However, when I create a new virtual machine using Virtual PC and add the existing VHD file, the machine doesn't boot. The initial boot screen flashes with the amount of RAM and then the screen goes black. If I turn off the VM and reboot in safe mode I can see the drivers being loaded until eventually it gets to crcdisk.sys and hangs indefinitely. Any ideas how to fix this? I'm not opposed to starting over from scratch if there's another method to turn my physical machine into a Virtual PC VM. Thanks! EDIT - I should add that the virtual drive is a system boot drive and not a secondary drive. EDIT - I tried booting from the install CD and doing a repair. The result was that the system could not be repaired due to a "driver error."

    Read the article

  • Solaris: detect hotswap SATA disk insert

    - by growse
    What's the method used on Solaris to get the system to rescan for new disks that have been hot-plugged on a SATA controller? I've got an HP X1600 NAS which had 9 drives configred in a ZFS pool. I've added 3 disks, but the format command still only shows the original 9. When I plugged them in, I saw this: cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=12 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=11 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=10 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO But can't figure out how to get the format command to see them so I know they've been detected by the system.

    Read the article

  • restoring a failed SBS 2000 box...

    - by Brad Pears
    Hi there, I read a post where you had mentioned you have had a PERC card blow up on you in an SBS box... I've got a similar situation where one of my RAID drives failed and then the power supply failed before I could replace the drive... I then replaced the power supply and the failed drive and reconfigured the RAID array. I had a recent full backup of the my Win2k SBS's C: drive stored on my SYmantec backup exec server so I installed win2K server on the c: partition and then once I had that up and running, installed the backup exec agent so as to do a restore of the entire c drive including system state. THis all worked just fine, until I had to reboot. I received an "incorrect drive configuration" error and then it hangs. I figure that likely makes sense becasue I think my RAID array is configured slightly different now in that the partitions may be sizeded ever so slightly differently now than they were before I think... Is there a way I can just restore from my backup BUT maybe exclude some of the registry and hidden boot files it wants to restore so that it is booting with the current configuration now active on that machine - not the pre blow up configuration files? I also read a post that indicated you might have to install the exact same service pack etc... etc.. before attemting a restore but that does not make sense to me being as the entire c drive contents are going to be overwritten by the restore anyway? THe basic OS install is just to be able to get the backup exec agent installed . I can;t understand why one would need to install the exact same SP level. CAn you shed some light on what I might be able to do to get this thing up and running? Thanks,Brad

    Read the article

  • How can I get my SATA DVDs working again?

    - by user269051
    My hard drive crashed (WinXPpro), so I took a C drive from a broken PC. The new C drive is Win7pro. Motherboard is MSI K8N Neo4 Platinum, with 4 hard drives installed on SATA 1-4 (nForce4 Ultra); the two DVD drives are loaded on SATA 7-8 (Silicon Image SATARAID5). I've tweaked BIOS settings every which way. The closest thing to success was when each DVD had both a CD and a DVD icon, and blinked green. No CD or DVD could be read in either drive. I assume that the problem resulted from the fact that my new C drive does not have the RAID drivers? I've tried loading from the floppy (doesn't work). I can't boot off the DVD/CD, and switching the DVD's SATA cable to the SATA 3 slot (and pulling one of the hard discs) didn't work. I'd like to be able to use the other two available SATA slots for a mirrored RAID drive, and get my DVDs working again. Any suggestions?

    Read the article

  • Why are SMART error rates going down?

    - by Jeff Shattock
    I have a hard drive that's part of a Linux software raid5 array. SMART has reported that its multi_zone_error_rate was 0, then 1, then 3. So I figured I better start backing up more frequently and prepare to replace the drive. Now, today, the multi_zone_error_rate of that very same drive is back down to 1. It seems that 2 errors unhappened while I wasn't looking. I've also seen simliar behaviour by inspecting the syslog on the server. Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 8 02:31:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 These are raw values, not the human-useful values that smartctl -a produces, but the behaviour is similar: error rates changing, then undoing the change. None of these are the drive that had the multi_zone weirdness. I haven't seen any problems from the RAID; its most recent scrub ( < 24 hours ago) came back totally clean. The only thing I can think of is that the SMART reporting circuitry on the drive isn't working properly all the time. The cables are in tight on the drive and board. What's going on here?

    Read the article

  • Best way to attach 96 tb to workstation

    - by user994179
    I'm running a workstation with dual xeon 5690's (12 physical/24 logical cores), 192 gb of ram (ie, maxed-out), Windows 7 64bit, 5 slots for adapter cards, and 1 tb of internal storage, with 5 more internal bays available. I have an app that creates data files totaling about 88 tbs. These are written once every 14 months, and the rest of the time the app only needs to read them; and 95% of the reads are sequential reads of huge chunks of data. I have some control over how big the individual files are, but ideally they would be between 5 and 8 tbs. The app will be reading from only one drive at a time, and the nature of the data is such that if (when) a drive dies I can restore the data to a new disk from tape. While it would be nice to be able to use the fastest drive/controllers available, at this point size matters more than speed. After doing lots of reading, I am leaning toward buying a bunch of cheap 2tb drives and putting them into a bunch of cheap enclosures. All this stuff is going into my home office, so I need to avoid the raised floor/refrigerated approach. My questions: Is the cheap drive/enclosure solution the best one for this situation? Given the nature of the app and the way the data is used, does RAID make sense? If so, which one? For huge sequential reads, would Usb 3.0 and eSata be a wash performance-wise? For each slot available on the workstation, can I hook up an enclosure that can hold multiple drives? Or is it one controller per drive? If I can have multiple drives on one controller, am I essentially splitting the bandwidth (throughput)? For example, if I have a 12 bay enclosure, is the throughput of the controller reduced by a factor of 12? Are there any Windows 7 volume/drive/capacity limits I should be aware of? Thanks

    Read the article

  • Dell R320 RAID 10 with CacheCade

    - by Geekman
    I'm looking for a higher-performance build for our 1RU Dell R320 servers, in terms of IOPS. Right now I'm fairly settled on: 4 x 600 GB 3.5" 15K RPM SAS RAID 1+0 array This should give good performance, but if possible, I want to also add an SSD Cache into the mix, but I'm not sure if there's enough room? According to the tech-specs, there's only up to 4 total 3.5" drive bays available. Is there any way to fit at least a single SSD drive along-side the 4x3.5" drives? I was hoping there's a special spot to put the cache SSD drive (though from memory, I doubt there'd be room). Or am I right in thinking that the cache drives are simply drives plugged in "normally" just as any other drive, but are nominated as CacheCade drives in the PERC controller? Are there any options for having the 4x600GB RAID 10 array, and the SSD cache drive, too? Based on the tech-specs (with up to 8x2.5" drives), maybe I need to use 2.5" SAS drives, leaving another 4 bays spare, plenty of room for the SSD cache drive. Has anyone achieved this using 3.5" drives, somehow?

    Read the article

  • How do I fix a super slow MacBook?

    - by MakingScienceFictionFact
    I'm running a black MacBook 4.1. Intel Core 2 Duo @ 2.4 GHz, 2 GB RAM, 250 GB hard disk drive, bus speed is 800 MHz. It's about three years old in excellent shape externally. I treat this thing like a baby. It used to run awesome, but now it's super slow at everything. I get the spinning pizza of death constantly. It takes a long time to boot up or load any program, even Safari and iTunes. iPhoto is terribly slow. The Internet doesn't work properly and it reminds me of a buggy PC. I've formatted it and re-installed Mac OS X 10.6 (with all updates), and I've done the disk repairs process. As an iOS developer this is driving me crazy, but luckily I have an iMac to work on in the day which is fast. I'm ready to format it again, but that didn't work last time. After the last format, I copied back files from an external drive so maybe the offending files were hidden in there somewhere. Here are the hard disk drive and RAM specifications. It is upgrade-able to 4 GB of RAM. Hard disk drive: The Fujitsu Mobile MHY2250BH is a 250 GB, standard hard disk drive. Its burst transfer rate is 150 Mbyte/s. This is a 5400 RPM drive and comes with an 8 MB buffer. RAM: two sticks of 1 GB DDR2 SDRAM, speed: 667 MHz.

    Read the article

  • Destination NAT Onto the Same Network from internal clients

    - by mivi
    I have a DSL router which acts as NAT (SNAT & DNAT). I have setup a server on internal network (10.0.0.2 at port 43201). DSL router was configured to "port forward" (or DNAT) all incoming connections to 10.0.0.2:43201. I created a virtual server for port forwarding on DSL router. I also added following iptables rules for port forwarding. iptables -t nat -A PREROUTING -p tcp -i ppp_0_1_32_1 --dport 43201 -j DNAT --to-destination 10.0.0.2:43201 iptables -I FORWARD 1 -p tcp -m state --state NEW,ESTABLISHED,RELATED -d 10.0.0.2 --dport 43201 -j ACCEPT # ppp_0_1_32_1 is routers external interface. # routers internal IP address is 10.0.0.1 and server is setup at 10.0.0.2:43201 Problem is that connections coming from external IP addresses are able to access internal server using External IP address, but internal clients (under NAT) are not able to access server using external IP address. Example: http://<external_address>:43201 is working from external clients But, internal clients are not able to access using http://<external_address>:43201 This seems to be similar to the problem described in http://www.netfilter.org/documentation/HOWTO/NAT-HOWTO-10.html (NAT HOW-TO Destination NAT Onto the Same Network). Firstly, I am not able to understand why is this a problem for internal clients? Secondly, what iptables rule will enable internal clients to access server using external IP address? Please suggest.

    Read the article

  • Cannot delete flash9.ocx

    - by Kara Marfia
    Some kinda voodoo, indeed. Bought a new boot drive, and it's time to use the old drive for data. I thought I'd save some time by just wiping the unneeded system folders, instead of backing up, formatting, and restoring. Wups! I have a single Adobe file that absolutely will not be deleted. G:\Windows\SysWOW64\Macromed\Flash\flash9.ocx - though it may have started with a different file name. I'm able to rename it, oddly enough. To be clear, the drive is currently plugged in externally. So I can boot the computer, plug this drive in afterward, and immediately attempt to delete. "File in use" box reads "the action can't be completed because the file is open in another program". I'd format at this point, but it's my white whale, and I have to know if Adobe has inserted some nasty little registry hack - or whatever it is - making this impossible. Since I'm sure it'll come up, I've taken ownership of the file - and this was the trick preventing me from deleting anything else on the drive - full rights on the file permissions, you name it, I've fiddled with the file itself. I'm about to try uninstalling flash from the system drive, in case that aligns the planets properly. Sometimes I wish I were less stubborn, and could just format already.

    Read the article

  • S.M.A.R.T. broken sectors

    - by Jeffrey Vandenborne
    Recently I received my hard drive (LaCie) that I've sent away for warranty, my disk failed, and I used Palimpsest Disk utility to check if anything was wrong in the S.M.A.R.T Status. And it said that there were a few broken sectors. So the next day, I went to the store and told the story. 4 weeks later I actually got my drive back. The first thing I did was plugging it in and starting the disk utility, and weirdly it showed me pretty much the exact same things, even the values of most tests were the same as they were before when my drive broke. The serial number is different though, but it does show a very peculiar value. Now I'm wondering, I'm almost sure it's the exact same drive and it still says I've got broken sectors, does it just say that because it has been cached in the drive somewhere while LaCie DID actually fix it? Or should I run the extended self test (which seems to take hours) first? Also I've tried the smartctl command tool, it says the drive has smart support, but it doesn't show anything, it says that it's enabled, but then it says that it's disabled, picture below The picture of the Disk utility: Thanks in advance

    Read the article

  • Doing port forwarding and then using it from within the internal network

    - by Ram Rachum
    We all know that by doing port forwarding on the router, computers from outside the network are able, on the specified ports, to access internal computers by targeting the external IP. I'm now replacing a TP-Link router with a D-link VDSL N 6740U router, (and copied over all the settings,) and I've noticed that one thing stopped working: With the TP-link router, you could access those port-forwarded computers from within the network, using the external IP, and they would be forwarded to the relevant computers. With the new D-Link router, it doesn't work. You might be wondering, why would you want to use the external IP and port forwarding when you're inside the internal network anyway and can just access the internal IP? One example for why this is useful: You have an iPhone app that connects to a service on an internal computer. The iPhone app knows to connect to the external IP. When we put that iPhone inside the internal network (via WiFi), it suddenly stops working, because it can't access the service from the external IP anymore. Is it an inherent property of D-Link routers that they do not allow accessing internal servers from inside the network by targeting the external IP? Or is there a way to make it work?

    Read the article

  • Could hybrid SSD + HDD be made with fixed internal partitions?

    - by Aaron
    I was pretty close to getting Seagate's Momentus XT but have been scared off by the many problems reported on forums and feedback sites, especially in Mac Book Pros. So I'm waiting for mk 2 with some extra flash and better reliablilty I'm assuming will come out this year. What would suit me better though is a 32+500 hybrid drive where I have more control over what is on the flash drive and what is on the disk drive. So there are 2 physical partitions within the one 2.5" hard drive enclosure which use different media internally (32GB for core files and 500GB for data and multimedia). The partitions would be locked so they can't be changed. - Or even better, the disk driver just makes them appear as two disks to the OS that share the same bus... Perhaps it's ok if the bios just sees the first drive until the OS is loaded. Is either of it technically possible? Obviously difficult to market outside of the enthusiast market. The SSD memory modules can be pretty small right, so they could even make them a card that plugs into a secondary connection on the enclosure. That would be good for computer builders as well as for upgrading and recoverability. Then future operating systems could recognise these system SSD drives and automatically install the OS + swap files on it. While placing document libraries on the larger data drive. While in the longer term HDD will probably disapear there will always be a trade off between speed, storage size and expense.

    Read the article

  • VMWare ESXi 5 - Expanded RAID 5 array - cannot access datastore

    - by Dayton Brown
    I'm using VMWare ESXi 5 and had a 2 TB RAID 5 setup on an HP DL360 with a P400i RAID card. I added two more 1 TB drives and using the SmartStart ACU, added the drives and expanded the logical disk. Now after booting back to ESXi, the server boots, but lists no available persistent storage. I've rescanned multiple times to no avail: the Datastore doesn't show up. I booted to GParted and the 1.8TB partition shows up, but it shows as unknown. Anyone have any good ideas? EDIT: Final Solution So after much gnashing of teeth, it was fairly simple to solve. I purchased an eSata 2 TB external drive and a PCI eSata card for my server. I then used Clonezilla to image the current partitions to my new external drive. You have to check "don't check drive sizes" in advanced mode, otherwise it will yell at you for have a smaller drive. For some reason my PCI card wouldn't boot on my HP server, so I hooked the drive up to another desktop I had, booted to VMWare, and copied the vmdk's to another drive. I'm going to blow out the RAID config and then create 1.5TB logical drives.

    Read the article

  • Power supply switch like stays off motherboard light turns on

    - by Sion
    I bought a computer at the thrift store yesterday. The computer powered on without any error beeps. Getting it back to the house determined that the CD and hard drive needed to be changed. Put in a populated hard drive to check, the computer turned on and seemed to function. Put in a new CD drive, and just put in a new Hard drive. I plugged it in to check and I noticed that the light for the power supply switch did not come on. But I did notice that the light on the motherboard is lit. and I could not turn the computer on. To help troubleshoot it I unplugged the CD and Hard drive. then re-plugged the power supply and switched it on and off. Nothing changed. Parts: Motherboard: Digital Home PSW DH deluxe Power Supply: FSP-Group FX700-GLN Did I accidentally unplug something while installing the hard drive? Is the Power supply fried somehow?

    Read the article

  • How to migrate WinXP from failing old HD to new one

    - by Péter Török
    Following this issue, we have all our important data backed up now. I also bought and installed a new replacement hard disk (WD 160GB PATA) as secondary (slave) drive. I created two primary NTFS partitions on it: a 40 GB system partition, and a 110GB data partition. In theory I could start reinstalling WinXP from scratch on the new system partition, then copying over all user data from the old drive to the new data partition. Once this is done, I could even throw away the old drive, or keep it just to see what happens. (Note: I don't want to clone the whole drive as it contains a dual boot setup with an old Linux installation which I don't need anymore, and anyway, a fresh reinstall would do WinXP good to get rid of many years' clutter.) However, I am lazy :-) The old HD is still functioning, the problem has not manifested again since. So I feel there is no need to hurry with a complete OS reinstall. What I don't know though is whether I will be able to install WinXP on the new system partition at a later stage without affecting the contents of the data partition on the same drive. If this is possible, I can just move over all our data to the new data partition to have it safe, then continue running WinXP from the old drive as long as it works. Does anyone see any problems/risks with this plan?

    Read the article

  • Hyper-V with multiple physical networks

    - by Yaman
    I have Hyper-V on my laptop with a wireless and Ethernet card, sometimes I connect using wireless card, and sometimes using the Ethernet cable. I am trying to configure Hyper-v to work always with internet provided to virtual machine. I have tried to create 2 virtual switches, one external to the Wireless network card, and the other one external to the Ethernet card. What happens is that the wireless network creates a bridge object in the network and sharing center\Network connections of windows 8, while the Ethernet does not. Unfortunately, they do not work together as external, i have to set the connected one to external and the other one as external, I also have to go to the properties of the bridge and virtual Ethernet properties to uncheck and check some components like: Client for Microsoft Networks Deterministic Network Enhancer VMWare Bridge Protocol QoS Packet Scheduler File and Printer Sharing for Microsoft Networks In order to make things work. Sometimes I keep the wireless network switch external, and go to another location (another wireless network), and it disconnects, i have to reconfigure the switches. Is there a way to do the configuration once and remain working wherever I connect, whether its Wireless or Ethernet and on any network with DHCP?

    Read the article

  • System randomly freezes yet mouse still moves, SSD out of reallocatable sectors, should I replace it?

    - by user784446
    This problem has lasted for the past 48 hours. The first time it happened, a program I was running stopped responding, so I tried to end it from task manager. The processes at first were listed fine until hovered upon. Eventually, despite the mouse still being able to move, after a few persisting clicks the mouse finally stopped moving. The screen went blank shortly thereafter. The second time it occurred, items on the screen stopped responding - hovering over the taskbar or such wouldn't elicit a response. Sound would still play however. Eventually, the mouse became unresponsive and the system restarted itself. I suspect that it may be a problem of my SSD drive. After looking through some Google search results, I downloaded HDTunePro to determine if there's a problem with the drive. Results returned a problem of reallocated sector count. An error scan also revealed 48 bad sectors. Also, an attempt to backup the contents of the most important areas of the drive returned a few explorer "Error: cannot read source from disk" errors. Should I ditch the drive and use another drive or is there anything that can be done to repair the drive? SSD: OCZ Petrol 64gb CPU: AMD Athlon II X4 640 RAM: Generic 3GB DDR2 Motherboard: Gigabyte MA74GM-S2H OS: Windows 7 Ultimate x64 Thanks!

    Read the article

  • System randomly freezes yet mouse still moves

    - by user784446
    This problem has lasted for the past 48 hours. The first time it happened, a program I was running stopped responding, so I tried to end it from task manager. The processes at first were listed fine until hovered upon. Eventually, despite the mouse still being able to move, after a few persisting clicks the mouse finally stopped moving. The screen went blank shortly thereafter. The second time it occurred, items on the screen stopped responding - hovering over the taskbar or such wouldn't elicit a response. Sound would still play however. Eventually, the mouse became unresponsive and the system restarted itself. I suspect that it may be a problem of my SSD drive. After looking through some Google search results, I downloaded HDTunePro to determine if there's a problem with the drive. Results returned a problem of reallocated sector count. An error scan also revealed 48 bad sectors. Also, an attempt to backup the contents of the most important areas of the drive returned a few explorer "Error: cannot read source from disk" errors. Should I ditch the drive and use another drive or is there anything that can be done to repair the drive? SSD: OCZ Petrol 64gb CPU: AMD Athlon II X4 640 RAM: Generic 3GB DDR2 Motherboard: Gigabyte MA74GM-S2H OS: Windows 7 Ultimate x64 Thanks!

    Read the article

  • How to prevent an SSD from disappearing from BIOS

    - by Midimatt
    I've only recently upgraded my old machine to a new one with a brand new 60gb SSD as my boot drive and a 1TB main drive. Paranoid about completely breaking my SSD, I read up on a lot of issues that I needed to watch out for, including making sure AHCI was turned on and trim enabled. PC has been working fine for a few weeks now, until today. My wife was watching some TV on the machine when it started to act strange and eventually blue screened. She rebooted and the boot mgr was missing. When I got home from work I checked the BIOS and the drive had disappeared. I panicked and looked up some possible fixes, and I discovered a large amount of people having problems with the drive firmware, especially on OCZ Vertex and Agility drives, and my drive is an Agility 3 drive. The problems included blue screens followed by missing drives, and a solution was to reset the CMOS and try again. This worked, and now everything seems to be working fine. My question is, is there any way to prevent this from happening? Am I missing a setting for my SSD? All of the posts I found were from early to mid-2011 nothing for the end of 2011 to 2012. So I am wondering if I've missed anything. EDIT: Checked my drives firmware and it is 2.15, which has had issues reported by users.

    Read the article

< Previous Page | 235 236 237 238 239 240 241 242 243 244 245 246  | Next Page >