Search Results

Search found 947 results on 38 pages for 'nic'.

Page 24/38 | < Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >

  • Multihomed Windows server and DNS resolution

    - by Mike K.
    I have a Windows 2008 server with two IP addresses assigned to a single NIC. The DNS settings are setup to register the connections's addresses on the DNS server. nslookup shows both IP addresses for the server name. How is name resolution done in this case, i.e. which IP address does the DNS server return for a host lookup? Or does it return both, and the client selects one of the addresses?

    Read the article

  • Find out the Mac address!!

    - by pirates-iiita
    hello everyone, Can anyone please tell the way to find out the mac address of a system which is: 1. Shutdown 2. Power plugged in 3. Connected to Lan 4. Nic card ON. Kindly post the solution as i urgently need it in my project... thank you

    Read the article

  • windows 2003 server : can't join domain

    - by phill
    I originally tried to rejoin a computer to a network which led to a "cannot find domain" error. The username/password box don't even come up. some tests i ran: I can ping the server, however I can't ping the domain name domain1.local. nslookup can't find the domain either. It looks to the isp's dns instead of my own to resolve the local machines. So i go to the dns and run netdiag.exe and gives me this error. DNS test . . . . . . . . . . . . . : Failed [WARNING] Cannot find a primary authoritative DNS server for the name 'stmartinsrv.stmartin.local.'. [RCODE_SERVER_FAILURE] The name 'srv.domain1.local.' may not be registered in DNS. [WARNING] The DNS entries for this DC are not registered correctly on DNS se rver '68.94.156.1'. Please wait for 30 minutes for DNS server replication. [WARNING] The DNS entries for this DC are not registered correctly on DNS se rver '68.94.157.1'. Please wait for 30 minutes for DNS server replication. [FATAL] No DNS servers have the DNS records for this DC registered. Redir and Browser test . . . . . . : Passed List of NetBt transports currently bound to the Redir NetBT_Tcpip_{04BB0F6B-06AE-4D60-80C8-2A7A24C1D87B} The redir is bound to 1 NetBt transport. List of NetBt transports currently bound to the browser NetBT_Tcpip_{04BB0F6B-06AE-4D60-80C8-2A7A24C1D87B} The browser is bound to 1 NetBt transport. then running dcdiag C:\Program Files\Support Toolsdcdiag Domain Controller Diagnosis Performing initial setup: Done gathering initial info. Doing initial required tests Testing server: Default-First-Site-Name\SRV Starting test: Connectivity The host 1c99f63c-49ec-40db-b3d3-6265c00fbd3e._msdcs.domain1.local cou ld not be resolved to an IP address. Check the DNS server, DHCP, server name, etc Although the Guid DNS name (1c99f63c-49ec-40db-b3d3-6265c00fbd3e._msdcs.domain1.local) couldn't be resolved, the server name (srv.domain1.local) resolved to the IP address (192.168.1.21) and was pingable. Check that the IP address is registered correctly with the DNS server. ......................... SRV failed test Connectivity Doing primary tests Testing server: Default-First-Site-Name\SRV Skipping all tests, because server SRV is not responding to directory service requests Running partition tests on : ForestDnsZones Starting test: CrossRefValidation ......................... ForestDnsZones passed test CrossRefValidation Starting test: CheckSDRefDom ......................... ForestDnsZones passed test CheckSDRefDom Running partition tests on : DomainDnsZones Starting test: CrossRefValidation ......................... DomainDnsZones passed test CrossRefValidation Starting test: CheckSDRefDom ......................... DomainDnsZones passed test CheckSDRefDom Running partition tests on : Schema Starting test: CrossRefValidation ......................... Schema passed test CrossRefValidation Starting test: CheckSDRefDom ......................... Schema passed test CheckSDRefDom Running partition tests on : Configuration Starting test: CrossRefValidation ......................... Configuration passed test CrossRefValidation Starting test: CheckSDRefDom ......................... Configuration passed test CheckSDRefDom Running partition tests on : domain1 Starting test: CrossRefValidation ......................... domain1 passed test CrossRefValidation Starting test: CheckSDRefDom ......................... domain1 passed test CheckSDRefDom Running enterprise tests on : domain1.local Starting test: Intersite ......................... domain1.local passed test Intersite Starting test: FsmoCheck ......................... domain1.local passed test FsmoCheck from previous postings, I've tried adding the domain suffix to the nic ip properties to both the client machine and the dc server which didn't help. note: there is only one nic on the server any ideas? thanks in advance

    Read the article

  • Supermicro IPMI on MBD-X8DAH+-F-O motherboard. Keyboard and mouse do not work after booting Windows Server 2008 R2

    - by LDelgado
    Hell Everyone, I built a server with the mentioned motherboard. I installed Windows Server 2008 R2 Enterprise on this server. IPMI is integrated on the motherboard with its own dedicated NIC. I've got that NIC configured with its own IP address. I can remote into it using IPMI, and I can remotely control the server settings before booting the OS ( BIOS, RAID configuration, etc). When the OS boots, I lose the mouse and keyboard. I cannot use the keyboard or mouse when installing the OS either. So the Keyboard and Mouse only work when no OS is loaded. Once the OS loads I lose it - that is my problem. I've been doing some research and trying a few things, but I have not been successful in fixing this issue. I may be wrong, but based on the things I've found online, it seems that the problem could be caused by the way the OS handles USB. The server is headless. There is no keyboard, mouse, or monitor plugged into it. When I boot up the OS and remote into it, I cannot see a mouse or keyboard listed in the Device Manager. Based on what I've read, it seems that the OS should detect a mouse and a keyboard when connecting remotely via IPMI. The following are the solutions I've tried. Nothing has worked so far: I've updated the firmware of the IPMI component to the latest firmware - 1.33. I made sure that the mouse mode was set to Absolute (Windows OS). I've loaded the factory defaults several times. I've enabled Port64h/60h Emulation under the USB settings in the BIOS. I've disabled USB legacy support in the BIOS. I made sure the firewall wasn't blocking IPMI (disabled the firewall). And that's about it. I've found threads in some forums from people having the same issue as me, but they were not running the same OS. They were either running Linux or FreeBSD. Most of them fixed their problem by selecting the right mouse mode (Linux in their case). There was one other that solved the problem by disabling USB Mass Storage mode. He stated "When I set it to disable USB Mass Storage when no image is loaded, the ukbd came alive, and I'm typing this on the IPMI Console. " source: http://freebsd.1045724.n5.nabble.com/IPMI-Console-No-luck-once-OS-is-booted-td3967868.html I suspect the solution described in the previous paragraph is somehow related to my problem. I've found several threads on the internet with issues describing the same problem, but none of them were with Windows Server 2008 R2. Again, I may be wrong, but it seems like that could be the issue. I just don't know how I go about applying a solution in Windows Server 2008 R2. In any case, I could use your expertise. Maybe I am missing something, or maybe I'm on the right track. Your help is much appreciated. Thank you in advance,

    Read the article

  • WNDR3700 Router + Cisco SG200-08 + LACP + Dual Uplink

    - by kobaltz
    Background I have a storage server that has several virtual machine images stored on them. I would store them locally, but I have limited space on my desktop (using SSD storage). I would like to increase the bandwidth between the desktop and the storage server by using two NICs on each computer. My original configuration allowed about 55MBps between the desktop and storage server. This storage server also has several TBs of documents, pictures, movies, vms, and ISO/programs. The storage server has 8 1.5TB hard drives in a RAID 10 configuration with a hardware RAID controller. The benchmarks on the RAID 10 are about 300MBps. Configuration In short, I am trying to bridge my switch and router. The switch is a small 8 port Cisco smart switch that supports 802.3ad LACP. I have two computers plugged into the switch, each with 2 Intel Gigabit NICs. The first computer is a Windows 7 machine that has the Intel ANS software installed. I have LACP configured with the computer and now show 3 NICs (2 Physical + 1 TEAM Virtual @ 2Gbps). It looks like this computer is configured correctly. I trunked the two ports that this computer is plugged into with the switch's web interface. The second computer is a homebrew storage box running debian. I also have the bonding enabled on this machine and the switch configured with LACP. Without having the WNDR3700 router in the picture yet, I am able to communicate between the Windows 7 machine and the debian box since they both have static IP addresses. With LACP enabled on both machines I am getting about 106-108MBps speeds. Issue I plug in a network cable from the switch into the router and enable DHCP on the desktop. I saw no need to have a static address on the desktop. My transfer rates are still from 106MBps-108MBps. While this is still a boost, I am trying to figure out how to get about 140-180MBps. I am thinking that I need to increase the bandwidth from the router to the switch. My switch allows 4 groups for port trunking. I plugged in a second network cable from the router to the switch. My question is, what is the proper way to fix this issue. Should I port trunk the two ports that are going from the switch to the router? Keep in mind that the router is a WNDR3700 and is unsure whether or not it supports LACP. I do have OpenWRT installed on the router, but it still wasn't clear in any documentation that I found if it supported 802.3ad LACP standards. I am also wondering if there needs to be anything changed within the Cisco settings. [Edit] - Corrected some numbers, wasn't really paying attention. It looks like the speeds though at least two NICs are bonded with LACP is still reaching the max bandwidth of one port. Is there a way to configure the switch so that I can increase this bandwidth? Also, on the storage server, I had a couple of extra NICs laying around and threw them on there as well. Another EDIT and More Findings I happened to look at the traffic of each individual NIC and think that I see the problem. I tested with a simple transfer for a 4GB file. I noticed that only one of the NICs was taking the load of the traffic. I then copied the file back to the Storage Server and noticed that the other NIC was sending out the traffic. I have 802.3ad LACP enabled on the two NICs and I see that it gets enabled dynamically on the switch's interface. Should I be using Static Link Aggregation?

    Read the article

  • General monitoring for SQL Server Analysis Services using Performance Monitor

    - by Testas
    A recent customer engagement required a setup of a monitoring solution for SSAS, due to the time restrictions placed upon this, native Windows Performance Monitor (Perfmon) and SQL Server Profiler Monitoring Tools was used as using a third party tool would have meant the customer providing an additional monitoring server that was not available.I wanted to outline the performance monitoring counters that was used to monitor the system on which SSAS was running. Due to the slow query performance that was occurring during certain scenarios, perfmon was used to establish if any pressure was being placed on the Disk, CPU or Memory subsystem when concurrent connections access the same query, and Profiler to pinpoint how the query was being managed within SSAS, profiler I will leave for another blogThis guide is not designed to provide a definitive list of what should be used when monitoring SSAS, different situations may require the addition or removal of counters as presented by the situation. However I hope that it serves as a good basis for starting your monitoring of SSAS. I would also like to acknowledge Chris Webb’s awesome chapters from “Expert Cube Development” that also helped shape my monitoring strategy:http://cwebbbi.spaces.live.com/blog/cns!7B84B0F2C239489A!6657.entrySimulating ConnectionsTo simulate the additional connections to the SSAS server whilst monitoring, I used ascmd to simulate multiple connections to the typical and worse performing queries that were identified by the customer. A similar sript can be downloaded from codeplex at http://www.codeplex.com/SQLSrvAnalysisSrvcs.     File name: ASCMD_StressTestingScripts.zip. Performance MonitorWithin performance monitor,  a counter log was created that contained the list of counters below. The important point to note when running the counter log is that the RUN AS property within the counter log properties should be changed to an account that has rights to the SSAS instance when monitoring MSAS counters. Failure to do so means that the counter log runs under the system account, no errors or warning are given while running the counter log, and it is not until you need to view the MSAS counters that they will not be displayed if run under the default account that has no right to SSAS. If your connection simulation takes hours, this could prove quite frustrating if not done beforehand JThe counters used……  Object Counter Instance Justification System Processor Queue legnth N/A Indicates how many threads are waiting for execution against the processor. If this counter is consistently higher than around 5 when processor utilization approaches 100%, then this is a good indication that there is more work (active threads) available (ready for execution) than the machine's processors are able to handle. System Context Switches/sec N/A Measures how frequently the processor has to switch from user- to kernel-mode to handle a request from a thread running in user mode. The heavier the workload running on your machine, the higher this counter will generally be, but over long term the value of this counter should remain fairly constant. If this counter suddenly starts increasing however, it may be an indicating of a malfunctioning device, especially if the Processor\Interrupts/sec\(_Total) counter on your machine shows a similar unexplained increase Process % Processor Time sqlservr Definately should be used if Processor\% Processor Time\(_Total) is maxing at 100% to assess the effect of the SQL Server process on the processor Process % Processor Time msmdsrv Definately should be used if Processor\% Processor Time\(_Total) is maxing at 100% to assess the effect of the SQL Server process on the processor Process Working Set sqlservr If the Memory\Available bytes counter is decreaing this counter can be run to indicate if the process is consuming larger and larger amounts of RAM. Process(instance)\Working Set measures the size of the working set for each process, which indicates the number of allocated pages the process can address without generating a page fault. Process Working Set msmdsrv If the Memory\Available bytes counter is decreaing this counter can be run to indicate if the process is consuming larger and larger amounts of RAM. Process(instance)\Working Set measures the size of the working set for each process, which indicates the number of allocated pages the process can address without generating a page fault. Processor % Processor Time _Total and individual cores measures the total utilization of your processor by all running processes. If multi-proc then be mindful only an average is provided Processor % Privileged Time _Total To see how the OS is handling basic IO requests. If kernel mode utilization is high, your machine is likely underpowered as it's too busy handling basic OS housekeeping functions to be able to effectively run other applications. Processor % User Time _Total To see how the applications is interacting from a processor perspective, a high percentage utilisation determine that the server is dealing with too many apps and may require increasing thje hardware or scaling out Processor Interrupts/sec _Total  The average rate, in incidents per second, at which the processor received and serviced hardware interrupts. Shoulr be consistant over time but a sudden unexplained increase could indicate a device malfunction which can be confirmed using the System\Context Switches/sec counter Memory Pages/sec N/A Indicates the rate at which pages are read from or written to disk to resolve hard page faults. This counter is a primary indicator of the kinds of faults that cause system-wide delays, this is the primary counter to watch for indication of possible insufficient RAM to meet your server's needs. A good idea here is to configure a perfmon alert that triggers when the number of pages per second exceeds 50 per paging disk on your system. May also want to see the configuration of the page file on the Server Memory Available Mbytes N/A is the amount of physical memory, in bytes, available to processes running on the computer. if this counter is greater than 10% of the actual RAM in your machine then you probably have more than enough RAM. monitor it regularly to see if any downward trend develops, and set an alert to trigger if it drops below 2% of the installed RAM. Physical Disk Disk Transfers/sec for each physical disk If it goes above 10 disk I/Os per second then you've got poor response time for your disk. Physical Disk Idle Time _total If Disk Transfers/sec is above  25 disk I/Os per second use this counter. which measures the percent time that your hard disk is idle during the measurement interval, and if you see this counter fall below 20% then you've likely got read/write requests queuing up for your disk which is unable to service these requests in a timely fashion. Physical Disk Disk queue legnth For the OLAP and SQL physical disk A value that is consistently less than 2 means that the disk system is handling the IO requests against the physical disk Network Interface Bytes Total/sec For the NIC Should be monitored over a period of time to see if there is anb increase/decrease in network utilisation Network Interface Current Bandwidth For the NIC is an estimate of the current bandwidth of the network interface in bits per second (BPS). MSAS 2005: Memory Memory Limit High KB N/A Shows (as a percentage) the high memory limit configured for SSAS in C:\Program Files\Microsoft SQL Server\MSAS10.MSSQLSERVER\OLAP\Config\msmdsrv.ini MSAS 2005: Memory Memory Limit Low KB N/A Shows (as a percentage) the low memory limit configured for SSAS in C:\Program Files\Microsoft SQL Server\MSAS10.MSSQLSERVER\OLAP\Config\msmdsrv.ini MSAS 2005: Memory Memory Usage KB N/A Displays the memory usage of the server process. MSAS 2005: Memory File Store KB N/A Displays the amount of memory that is reserved for the Cache. Note if total memory limit in the msmdsrv.ini is set to 0, no memory is reserved for the cache MSAS 2005: Storage Engine Query Queries from Cache Direct / sec N/A Displays the rate of queries answered from the cache directly MSAS 2005: Storage Engine Query Queries from Cache Filtered / Sec N/A Displays the Rate of queries answered by filtering existing cache entry. MSAS 2005: Storage Engine Query Queries from File / Sec N/A Displays the Rate of queries answered from files. MSAS 2005: Storage Engine Query Average time /query N/A Displays the average time of a query MSAS 2005: Connection Current connections N/A Displays the number of connections against the SSAS instance MSAS 2005: Connection Requests / sec N/A Displays the rate of query requests per second MSAS 2005: Locks Current Lock Waits N/A Displays thhe number of connections waiting on a lock MSAS 2005: Threads Query Pool job queue Length N/A The number of queries in the job queue MSAS 2005:Proc Aggregations Temp file bytes written/sec N/A Shows the number of bytes of data processed in a temporary file MSAS 2005:Proc Aggregations Temp file rows written/sec N/A Shows the number of bytes of data processed in a temporary file 

    Read the article

  • SPARC T3-1 Record Results Running JD Edwards EnterpriseOne Day in the Life Benchmark with Added Batch Component

    - by Brian
    Using Oracle's SPARC T3-1 server for the application tier and Oracle's SPARC Enterprise M3000 server for the database tier, a world record result was produced running the Oracle's JD Edwards EnterpriseOne applications Day in the Life benchmark run concurrently with a batch workload. The SPARC T3-1 server based result has 25% better performance than the IBM Power 750 POWER7 server even though the IBM result did not include running a batch component. The SPARC T3-1 server based result has 25% better space/performance than the IBM Power 750 POWER7 server as measured by the online component. The SPARC T3-1 server based result is 5x faster than the x86-based IBM x3650 M2 server system when executing the online component of the JD Edwards EnterpriseOne 9.0.1 Day in the Life benchmark. The IBM result did not include a batch component. The SPARC T3-1 server based result has 2.5x better space/performance than the x86-based IBM x3650 M2 server as measured by the online component. The combination of SPARC T3-1 and SPARC Enterprise M3000 servers delivered a Day in the Life benchmark result of 5000 online users with 0.875 seconds of average transaction response time running concurrently with 19 Universal Batch Engine (UBE) processes at 10 UBEs/minute. The solution exercises various JD Edwards EnterpriseOne applications while running Oracle WebLogic Server 11g Release 1 and Oracle Web Tier Utilities 11g HTTP server in Oracle Solaris Containers, together with the Oracle Database 11g Release 2. The SPARC T3-1 server showed that it could handle the additional workload of batch processing while maintaining the same number of online users for the JD Edwards EnterpriseOne Day in the Life benchmark. This was accomplished with minimal loss in response time. JD Edwards EnterpriseOne 9.0.1 takes advantage of the large number of compute threads available in the SPARC T3-1 server at the application tier and achieves excellent response times. The SPARC T3-1 server consolidates the application/web tier of the JD Edwards EnterpriseOne 9.0.1 application using Oracle Solaris Containers. Containers provide flexibility, easier maintenance and better CPU utilization of the server leaving processing capacity for additional growth. A number of Oracle advanced technology and features were used to obtain this result: Oracle Solaris 10, Oracle Solaris Containers, Oracle Java Hotspot Server VM, Oracle WebLogic Server 11g Release 1, Oracle Web Tier Utilities 11g, Oracle Database 11g Release 2, the SPARC T3 and SPARC64 VII+ based servers. This is the first published result running both online and batch workload concurrently on the JD Enterprise Application server. No published results are available from IBM running the online component together with a batch workload. The 9.0.1 version of the benchmark saw some minor performance improvements relative to 9.0. When comparing between 9.0.1 and 9.0 results, the reader should take this into account when the difference between results is small. Performance Landscape JD Edwards EnterpriseOne Day in the Life Benchmark Online with Batch Workload This is the first publication on the Day in the Life benchmark run concurrently with batch jobs. The batch workload was provided by Oracle's Universal Batch Engine. System RackUnits Online Users Resp Time (sec) BatchConcur(# of UBEs) BatchRate(UBEs/m) Version SPARC T3-1, 1xSPARC T3 (1.65 GHz), Solaris 10 M3000, 1xSPARC64 VII+ (2.86 GHz), Solaris 10 4 5000 0.88 19 10 9.0.1 Resp Time (sec) — Response time of online jobs reported in seconds Batch Concur (# of UBEs) — Batch concurrency presented in the number of UBEs Batch Rate (UBEs/m) — Batch transaction rate in UBEs/minute. JD Edwards EnterpriseOne Day in the Life Benchmark Online Workload Only These results are for the Day in the Life benchmark. They are run without any batch workload. System RackUnits Online Users ResponseTime (sec) Version SPARC T3-1, 1xSPARC T3 (1.65 GHz), Solaris 10 M3000, 1xSPARC64 VII (2.75 GHz), Solaris 10 4 5000 0.52 9.0.1 IBM Power 750, 1xPOWER7 (3.55 GHz), IBM i7.1 4 4000 0.61 9.0 IBM x3650M2, 2xIntel X5570 (2.93 GHz), OVM 2 1000 0.29 9.0 IBM result from http://www-03.ibm.com/systems/i/advantages/oracle/, IBM used WebSphere Configuration Summary Hardware Configuration: 1 x SPARC T3-1 server 1 x 1.65 GHz SPARC T3 128 GB memory 16 x 300 GB 10000 RPM SAS 1 x Sun Flash Accelerator F20 PCIe Card, 92 GB 1 x 10 GbE NIC 1 x SPARC Enterprise M3000 server 1 x 2.86 SPARC64 VII+ 64 GB memory 1 x 10 GbE NIC 2 x StorageTek 2540 + 2501 Software Configuration: JD Edwards EnterpriseOne 9.0.1 with Tools 8.98.3.3 Oracle Database 11g Release 2 Oracle 11g WebLogic server 11g Release 1 version 10.3.2 Oracle Web Tier Utilities 11g Oracle Solaris 10 9/10 Mercury LoadRunner 9.10 with Oracle Day in the Life kit for JD Edwards EnterpriseOne 9.0.1 Oracle’s Universal Batch Engine - Short UBEs and Long UBEs Benchmark Description JD Edwards EnterpriseOne is an integrated applications suite of Enterprise Resource Planning (ERP) software. Oracle offers 70 JD Edwards EnterpriseOne application modules to support a diverse set of business operations. Oracle's Day in the Life (DIL) kit is a suite of scripts that exercises most common transactions of JD Edwards EnterpriseOne applications, including business processes such as payroll, sales order, purchase order, work order, and other manufacturing processes, such as ship confirmation. These are labeled by industry acronyms such as SCM, CRM, HCM, SRM and FMS. The kit's scripts execute transactions typical of a mid-sized manufacturing company. The workload consists of online transactions and the UBE workload of 15 short and 4 long UBEs. LoadRunner runs the DIL workload, collects the user’s transactions response times and reports the key metric of Combined Weighted Average Transaction Response time. The UBE processes workload runs from the JD Enterprise Application server. Oracle's UBE processes come as three flavors: Short UBEs < 1 minute engage in Business Report and Summary Analysis, Mid UBEs > 1 minute create a large report of Account, Balance, and Full Address, Long UBEs > 2 minutes simulate Payroll, Sales Order, night only jobs. The UBE workload generates large numbers of PDF files reports and log files. The UBE Queues are categorized as the QBATCHD, a single threaded queue for large UBEs, and the QPROCESS queue for short UBEs run concurrently. One of the Oracle Solaris Containers ran 4 Long UBEs, while another Container ran 15 short UBEs concurrently. The mixed size UBEs ran concurrently from the SPARC T3-1 server with the 5000 online users driven by the LoadRunner. Oracle’s UBE process performance metric is Number of Maximum Concurrent UBE processes at transaction rate, UBEs/minute. Key Points and Best Practices Two JD Edwards EnterpriseOne Application Servers and two Oracle Fusion Middleware WebLogic Servers 11g R1 coupled with two Oracle Fusion Middleware 11g Web Tier HTTP Server instances on the SPARC T3-1 server were hosted in four separate Oracle Solaris Containers to demonstrate consolidation of multiple application and web servers. See Also SPARC T3-1 oracle.com SPARC Enterprise M3000 oracle.com Oracle Solaris oracle.com JD Edwards EnterpriseOne oracle.com Oracle Database 11g Release 2 Enterprise Edition oracle.com Disclosure Statement Copyright 2011, Oracle and/or its affiliates. All rights reserved. Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners. Results as of 6/27/2011.

    Read the article

  • Intel Corporation Ethernet Connection does not start properly

    - by Oscar Alejos
    I'm experiencing some problems when trying to connect my PC to the router through a switch. When the PC is directly connected to the router, everything works fine, Ubuntu (14.04) starts normally, and the Internet connection runs inmediately. The Ethernet controller is the Intel Corporation Ethernet Connection, as lspci returns: $ lspci | grep Eth 00:19.0 Ethernet controller: Intel Corporation Ethernet Connection I217-V (rev 04) However, when I try to connect through the switch what I get is the following. dmesg returns: $ dmesg | grep eth [ 1.035585] e1000e 0000:00:19.0 eth0: registered PHC clock [ 1.035587] e1000e 0000:00:19.0 eth0: (PCI Express:2.5GT/s:Width x1) 00:22:4d:a7:be:5d [ 1.035589] e1000e 0000:00:19.0 eth0: Intel(R) PRO/1000 Network Connection [ 1.035625] e1000e 0000:00:19.0 eth0: MAC: 11, PHY: 12, PBA No: FFFFFF-0FF [ 1.357838] IPv6: ADDRCONF(NETDEV_UP): eth0: link is not ready [ 2.165413] IPv6: ADDRCONF(NETDEV_UP): eth0: link is not ready [ 2.165574] IPv6: ADDRCONF(NETDEV_UP): eth0: link is not ready [ 2.641287] IPv6: ADDRCONF(NETDEV_UP): eth0: link is not ready [ 16.715086] e1000e: eth0 NIC Link is Up 100 Mbps Full Duplex, Flow Control: Rx/Tx [ 16.715090] e1000e 0000:00:19.0 eth0: 10/100 speed: disabling TSO [ 16.715117] IPv6: ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready It looks like eth0 is properly working. Actually, nm-tool returns: $ nm-tool - Device: eth0 [Conexión cableada] ------------------------------------------- Type: Wired Driver: e1000e State: connected Default: yes HW Address: 00:22:4D:A7:BE:5D Capabilities: Carrier Detect: yes Speed: 100 Mb/s Wired Properties Carrier: on IPv4 Settings: Address: 192.168.1.30 Prefix: 24 (255.255.255.0) Gateway: 192.168.1.1 DNS: 80.58.61.250 DNS: 80.58.61.254 DNS: 192.168.1.1 However, ping returns: $ ping 192.168.1.1 PING 192.168.1.1 (192.168.1.1) 56(84) bytes of data. From 192.168.1.30 icmp_seq=1 Destination Host Unreachable From 192.168.1.30 icmp_seq=2 Destination Host Unreachable From 192.168.1.30 icmp_seq=3 Destination Host Unreachable The connection is restored by restarting it: # ifconfig eth0 down # ifconfig eth0 up From this point on, everything runs smoothly, as if the PC were directly connected to the router. It seems to be an issue related to the integrated LAN adaptor and the Ethernet controller, since my laptop connects without any problem. My desktop board is an Intel DB85FL. I'd be grateful if anyone could give some ideas on how to solve this issue. Thank you in advance.

    Read the article

  • Installing Win7 over PXE through Serva fails on Loading Network Resources

    - by Armand
    Trying to install Win7 OS to a Lenovo E335 with no DVD/CD. I have to do it either over PXE/Network or USB. Although I am able to get passt the installation menu of Serva, it fails on Loading Network Resources ... FAILED No NIC/Driver, ABORTING! This is the only log on the Serva Client PC and nothing on the Serva-server. Would appreciate if someone can tell me how to go pass this error. THe network card works fine, it has already loaded the Windows installation structure on a X: drive on the new laptop. Another detail: I am using a normal Ethernet Cable to connect the PCs. Should this be enough or a crossover cable is a must in this case?

    Read the article

  • OpenIndiana installation hangs at 2% - Preparing disk for OpenIndiana installation

    - by Chris S
    I've been trying to install OpenIndiana on an HP DL320 G6 for a while now. I've got a 16GB HP SDHC card in the onboard slot and a SATA CD-Rom with oi-dev-151a-text-x86.iso burnt to a disc. Installation seems to progress fine until I get to the actual installation portion. The SD card is picked up as a USB Disk. All the other configuration options are very 'normal' (there really aren't many options to begin with). Automatic NIC configuration. The installer starts "Installing OpenIndiana", does a few steps, then gets to "Preparing disk for OpenIndiana installation" at 2%; and just sits there. I've let it sit for half an hour now ans still no progress. How can I get past this issue? PS I'm not terribly familiar with OpenSolaris, but am with FreeBSD and *nix CLIs in general.

    Read the article

  • "No active network adapters found" Hyper-V 2008 R2

    - by mnemosyn
    I fiddled around with the virtual network settings of my Hyper-V server, because Windows Update failed to run in the VMs. I set the flag that makes the NIC exclusively usable by the VM. Now, the host system tells me it has no active network adapters. What does that even mean? According to netsh, there are three enabled network connections. I tried to restart the NICs using devcon.exe (the correct x64 version), but that doesn't make any difference - still, devcon reports the NICs are there and they are activated?! Is there any way I can force the host to re-enable the NICs?

    Read the article

  • Cisco VPN Client connects but unable to ping or RDP

    - by bryanroth
    I'm a developer and don't have much networking expertise, so bare with me. I'm using the Cisco VPN Client 5.0.02.0090 to connect to my work's VPN that way I can RDP into my work computer. Once connected, I can't ping anything on the local network once connected to the VPN thus I am unable to access my work's network. This used to work about two weeks ago but abruptly stopped working today. However, I have the Cisco VPN Client installed on my laptop and I am able to ping and RDP into my work computer from there. Both my desktop and laptop computers are connected to the same router at home. I have tried the following so far: Rebooted my computer Reinstalled VPN client Updated NIC drivers Disabled firewall Opened up ports 500, 4500, and 10000 Any help would be much appreciated. Thanks!

    Read the article

  • HP Network Utility Error

    - by William Ricci
    Using the HP Network Utility to team 2 ports on Windows 2008 R2 Standard results in this error:----- An error occurred when making a call into the operating system. Happens on either of two cards that are installed. This happened before and after upgrading to PSP 9.10. Uninstalled the HP Network Configuration Utility and re-installed version 10.65.0.6. Updated NIC drivers. NC382i DP - HP Broadcom 1Gb Multifunction Driver 7.4.23.0 (from 6.2.9.0) NC365T - Intel E1R 11.14.80.0 (from 11.14.49.0)

    Read the article

  • tcptrack shows SYN_SENT connections, does that mean the SYN package reached the server?

    - by xpu
    our server suffered a serious connection timeout problem, so we track tcp connection with tcptrack we found out that, if the client started to connect to the server, tcptrack shows the connection, but in SYN_SENT status, and netstat -nat shows nothing. (tcptrack & netstat all runs on the server) does this mean the syn request reached the server? and no syn/ack was sent back? why the tcptrack could report this connection but netstat could not? what could be the problem that a general apache could not establish a connection with the client? i did a bench test using ab in the same intranet, to the specified NIC, it handled 10000 concurrent connection and 400000 requests ok ps: this doesn't happen every time, but did happened a lot pps: is there any good tools to trace where the tcp connection was lost?

    Read the article

  • Troubleshooting PXE-E11: ARP Timeout error under VMware ESXi 4 and HPSA 7.8

    - by warren
    I am running HP Server Automation v7.8 in a lab environment on VMware ESXi, managed via vSphere 4. On the same host I have several small VMs for OS provisioning testing (512MB RAM, 10GB hdd, one NIC on the same vSwitch that HPSA is running on). DHCP is configured to hand-out addresses in the 192.168.10.151-200 range. On boot of the VM, it receives an IP (eg 192.168.10.198) within seconds. However, after it receives its IP, a PXE-E11: ARP Timeout error occurs in trying to boot from the DHCP server. I do not know if this is a HPSA-specific error, as I have seen reports of the PXE-E11 error on various forums. Proposed solutions I have seen so far (changing VLAN settings, for example) have not been applicable to my environment. Are there any pointers/troubleshooting steps that can be taken to resolve this?

    Read the article

  • ESXI 4 IPMI 2.0 - Cannot connect to IPMI after boot past bios

    - by adamflavell
    Dear All, I would appreciate any help here. I have a Supermicro 6016T-NTRF running ESXI 4 fine. The health monitors are showing up so ESXI is picking up the IPMI status. But I cannot connect to the host remotely via the dedicated IPMI nic. When the machine is in bios section I CAN connect but as soon as ESXI starts to boot I get blocked. Supermicro say the issue must be that ESXI is blocking the IPMI ports. How can this be corrected? I have read that there is no firewall on ESXI 4. Thanks, Adam

    Read the article

  • Installing esx 3.5 on hpblade 460c G7

    - by stillStudent
    I was trying to install ESX 3.5 on hp blade 460c but it fails with error no 'network adapter is detected'. Anybody has work around for this. I also tried to install ESX 4.1, it also had the same problem but in case of 4.1 there is support to add your custom driver while installing. So I added NIC drivers and installation completed successfully. ESX 3.5 installtion does not support adding custom drivers while installing. I can't use ESX 4.1 because it does not support 'license server' configuration and only asks for license file(key). I do not have license keys, I only have vmware license server. That is the reason I have to be with ESX 3.5.

    Read the article

  • SOLVED: network issue ubuntu 8.04 in vmware esx

    - by hoberion
    ok, this is really pissing me off I have one ubuntu 8.04 instance running on vmware (esx) which decided after a reboot to stop resolving dns requests, I also cant connect to it using ssh although I can ping the server and its really that server (when I shutdown the server the ping also stops) stuff I tried: - reboot again :) - nslookup - serverip - setting networking to dhcp - offering some cute kittens to lucifer - removing the virtual nic and adding another (to get a different mac) - migrating the instance to another esx host - drinking 20 cups of espresso - stopped all services - running dnsmasq on another server and connecting to that dns - tcpdumping - disabling ip6 symptoms: cant resolve anything nslookup just says "no servers found..." although I can ping the servers traceroute to gateway doesnt work (even with traceroute -4 -n gatewayip) collegues laughing at me any thoughts solved it: a collegue told me to upgrade/reinstall the vmware tools, I did and it solved my issue after rebooting

    Read the article

  • Determine nginx reverse-proxy load limits

    - by Aaron
    Hi all: I have an nginx server (CentOS 5.3, linux) that I'm using as a reverse-proxy load-balancer in front of 8 ruby on rails application servers. As our load on these servers increases, I'm beginning to wonder at what point will the nginx server become a bottleneck? The CPUs are hardly used, but that's to be expected. The memory seems to be fine. No IO to speak of. So is my only limitation bandwidth on the NICs? Currently, according to some cacti graphs, the server is hitting around 700Kbps ( 5 min average ) on each NIC during high load. I would think this is still pretty low. Or, will the limit be in sockets or some other resource in the operating system? Thanks for any thoughts and insights. Aaron

    Read the article

  • Unable to resolve FQDN, hostname works

    - by HannesFostie
    We are having an issue where computers who are not part of the domain cannot resolve the FQDN of a server (but regular hostname and ip do resolve). The strange thing is that this does work when the computer is added to the network. Our domain name is rather long, its something along the lines of "team.dept.company.com", could that be it? DHCP server passes along the proper DNS, Name and WINS servers, as well as the domain name. I thought that should've solved the problem, but apparently not really. Our domain is still windows2003 EDIT: I am starting to believe I can narrow this down to a problem either with the vmware tools NIC drivers that are embedded in my winPE boot image, or to the fact that I'm trying to do this from inside a VM. Pinging a FQDN at the same time when using a different task sequence on a physical machine works.

    Read the article

  • Poor home office network performance and cannot figure out where the issue is

    - by Jeff Willener
    This is the most bizarre issue. I have worked with small to mid size networks for quite a long time and can say I'm comfortable connecting hardware. Where you will start to lose me is with managed switches and firewalls. To start, let me describe my network (sigh, shouldn't but I MUST solve this). 1) Comcast Cable Internet 2) Motorola SURFboard eXtreme Cable Modem. a) Model: SB6120 b) DOCSIS 3.0 and 2.0 support c) IPv4 and IPv6 support 3-A) Cisco Small Business RV220W Wireless N Firewall a) Latest firmware b) Model: RV220W-A-K9-NA c) WAN Port to Modem (2) d) vlan 1: work e) vlan 2: everything else. 3-B) D-Link DIR-615 Draft 802.11 N Wireless Router a) Latest firmware b) WAN Port to Modem (2) 4) Servers connected directly to firewall a) If firewall 3-A, then vlan 1 b) CAT5e patch cables c) Dell PowerEdge 1400SC w/ 10/100 integrated NIC (Domain Controller, DNS, former DHCP) d) Dell PowerEdge 400SC w/ 10/100/1000 integrated NIC (VMWare Server) 4) Linksys EZXS88W unmanaged Workgroup 10/100 Switch a) If firewall 3-A, then vlan 2 b) 25' CAT5e patch cable to firewall (3-A or 3-B) c) Connects xBox 360, Blu-Ray player, PC at TV 5) Office equipment connected directly to firewall a) If firewall 3-A, then vlan 1 b) ~80' CAT6 or CAT5e patch cable to firewall (3-A or 3-B) c) Connects 1) Dell Latitude laptop 10/100/1000 2) Dell Inspiron laptop 10/100 3) Dell Workstation 10/100/1000 (Pristine host, VMWare Workstation 7.x with many bridged VM's) 4) Brother Laser Printer 10/100 5) Epson All-In-One Workforce 310 10/100 5-A) NetGear FS116 unmanaged 10/100 switch a) I've had this switch for a long time and never had issues. 5-B) NetGear GS108 unmanaged 10/100/1000 switch a) Bought new for this issue and returned. 5-C) Linksys SE2500 unmanaged 10/100/1000 switch a) Bought new for this issue and returned. 5-D) TP-Link TL-SG10008D unmanaged 10/100/1000 a) Bought new for this issue and still have. 6) VLan 1 Wireless Connections (on same subnet if 3-B) a) Any of those at 5c b) HP Laptop 7) VLan 2 Wireless Connection (on same subnet if 3-B) a) IPad, IPod b) Compaq Laptop c) Epson Wireless Printer Shew, without hosting a diagram I hope that paints a good picture. The Issue The breakdown here is at item 5. No matter what I do I cannot have a switch at 5 and have to run everything wireless regardless of router. Issues related to using a switch (point 5 above) SpeedTest is good. Poor throughput to other devices if can communicate at all. Usually cannot ping other devices even on the same switch although, when able, ping times are good. Eventual lose of connectivity and can "sometimes" be restored by unplugging everything for several days, not minutes or hours but we're talking a week if at all. Directly connect to computer gives good internet connection however throughput to other devices connected to firewall is at best horrible. Yet printing doesn't seem to be an issue as long as they are connected via wireless. I have to force the RV220W to 1000Mb on the respective port if using a Gig Switch Issues related to using wireless in place of a switch (point 5 above) Poor throughput to other devices if can communicate. SpeedTest is good. Bottom line Internet speeds are awesome. By the way, Comcast went WAY above and beyond to make sure it was not them. They rewired EVERYTHING which did solve internet drops. Computer to computer connections are garbage Cannot get switch at 5 to work, yet other at 4 has never had an issue. Direct connection, bypass switch, is good for DHCP and internet. DNS must be on server, not firewall. Cisco insists its my switches but as you can see I have used four and two different cables with the same result. My gut feeling is something is happening with routing. But I'm not smart enough to know that answer. I run a lot of VM's at 5-c-3, could that cause it? What's different compared to my previous house is I have introduced Gigabit hardware (firewall/switches/computers). Some of my computers might have IPv6 turned on if I haven't turned it off already. I'm truly at a loss and hope anyone has some crazy idea how to solve this. Bottom line, I need a switch in my office behind the firewall. I've changed everything. The real crux is I will find a working solution and, again, after days it will stop working. So this means I cannot isolate if its a computer since I have to use them. Oh and a solution is not throwing more money at this. I'm well into $1k already. Yah, lame.

    Read the article

  • windows 7 no internet access

    - by Kyle
    Just did a fresh install of Windows 7, and the network and sharing center says no internet access. Disabling and enabling the adapter seems to fix the issue temporarily, but the internet stops working shortly after. I have installed the latest NIC drivers and have installed all Windows updates. I have also tried manually setting the ip/gateway/dns and running netsh int ip reset in an elevated command prompt. I am running Windows 7 Home Premium 64bit with a wired connection. I have searched for hours, but have found no working solutions. Does anyone have any ideas?

    Read the article

< Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >