  • wifi hardware switch doesn't work on a Dell 1018

    - by user42566
    I have a problem with my Dell 1018 Inspiron. I can't switch the wifi on, through the key on the keyboard. I think it's a driver problem since Ubuntu 11.10. This are the versions i tried: Ubuntu 10.04 / 10.10 It's possible to install the driver by hand: sudo add-apt-repository ppa:lexical/hwe-wireless sudo apt-get update sudo apt-get install rtl8192ce-dkms Ubuntu 11.04 It works out of the box Ubuntu 11.10 / 12.04 I haven’t found any solution for these versions. The "ppa:lexical/hwe-wireless" doesn't work for these versions. It says Can not find package rtl8192ce-dkms. The window of additional drivers is empty. So I can't install the driver. The wired network works good. Here is some information: 0: dell-wifi: Wireless LAN Soft blocked: no Hard blocked: no 1: phy0: Wireless LAN Soft blocked: no Hard blocked: yes sudo lshw -class network *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:05:00.0 logical name: eth0 version: 05 serial: 5c:26:0a:0d:20:10 size: 10Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half firmware=rtl_nic/rtl8105e-1.fw latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:43 ioport:2000(size=256) memory:f0f2c000-f0f2cfff memory:f0f18000-f0f1bfff *-network description: Wireless interface product: RTL8188CE 802.11b/g/n WiFi Adapter vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:07:00.0 logical name: wlan0 version: 01 serial: 70:f1:a1:fe:15:bd width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=rtl8192ce driverversion=3.2.0-22-generic-pae firmware=N/A ip=192.168.1.76 latency=0 link=yes multicast=yes wireless=IEEE 802.11bgn resources: irq:17 ioport:3000(size=256) memory:f0100000-f0103fff mark@mark-Inspiron-1018:~$ mark@mark-Inspiron-1018:~$ sudo lspci -nn 00:00.0 Host bridge [0600]: Intel Corporation N10 Family DMI Bridge [8086:a010] 00:02.0 VGA compatible controller [0300]: Intel Corporation N10 Family Integrated Graphics Controller [8086:a011] 00:02.1 Display controller [0380]: Intel Corporation N10 Family Integrated Graphics Controller [8086:a012] 00:1b.0 Audio device [0403]: Intel Corporation N10/ICH 7 Family High Definition Audio Controller [8086:27d8] (rev 02) 00:1c.0 PCI bridge [0604]: Intel Corporation N10/ICH 7 Family PCI Express Port 1 [8086:27d0] (rev 02) 00:1c.1 PCI bridge [0604]: Intel Corporation N10/ICH 7 Family PCI Express Port 2 [8086:27d2] (rev 02) 00:1d.0 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB UHCI Controller #1 [8086:27c8] (rev 02) 00:1d.1 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB UHCI Controller #2 [8086:27c9] (rev 02) 00:1d.2 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB UHCI Controller #3 [8086:27ca] (rev 02) 00:1d.3 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB UHCI Controller #4 [8086:27cb] (rev 02) 00:1d.7 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB2 EHCI Controller [8086:27cc] (rev 02) 00:1e.0 PCI bridge [0604]: Intel Corporation 82801 Mobile PCI Bridge [8086:2448] (rev e2) 00:1f.0 ISA bridge [0601]: Intel Corporation NM10 Family LPC Controller [8086:27bc] (rev 02) 00:1f.2 SATA controller [0106]: Intel Corporation N10/ICH7 Family SATA Controller [AHCI mode] [8086:27c1] (rev 02) 00:1f.3 SMBus [0c05]: Intel Corporation N10/ICH 7 Family SMBus Controller [8086:27da] (rev 02) 05:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8101E/RTL8102E PCI Express Fast Ethernet controller [10ec:8136] (rev 05) 07:00.0 Network controller [0280]: Realtek Semiconductor Co., Ltd. RTL8188CE 802.11b/g/n WiFi Adapter [10ec:8176] (rev 01) mark@mark-Inspiron-1018:~$ mark@mark-Inspiron-1018:~$ lsusb Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 002: ID 174f:1127 Syntek mark@mark-Inspiron-1018:~$

    Read the article

  • Abstraction, Politics, and Software Architecture

    Abstraction can be defined as a general concept and/or idea that lack any concrete details. Throughout history this type of thinking has led to an array of new ideas and innovations as well as increased confusion and conspiracy. If one was to look back at our history they will see that abstraction has been used in various forms throughout our past. When I was growing up I do not know how many times I heard politicians say “Leave no child left behind” or “No child left behind” as a major part of their campaign rhetoric in regards to a stance on education. As you can see their slogan is a perfect example of abstraction because it only offers a very general concept about improving our education system but they do not mention how they would like to do it. If they did then they would be adding concrete details to their abstraction thus turning it in to an actual working plan as to how we as a society can help children succeed in school and in life, but then they would not be using abstraction. By now I sure you are thinking what does abstraction have to do with software architecture. You are valid in thinking this way, but abstraction is a wonderful tool used in information technology especially in the world of software architecture. Abstraction is one method of extracting the concepts of an idea so that it can be understood and discussed by others of varying technical abilities and backgrounds. One ways in which I tend to extract my architectural design thoughts is through the use of basic diagrams to convey an idea for a system or a new feature for an existing application. This allows me to generically model an architectural design through the use of views and Unified Markup Language (UML). UML is a standard method for creating a 4+1 Architectural View Models. The 4+1 Architectural View Model consists of 4 views typically created with UML as well as a general description of the concept that is being expressed by a model. The 4+1 Architectural View Model: Logical View: Models a system’s end-user functionality. Development View: Models a system as a collection of components and connectors to illustrate how it is intended to be developed.  Process View: Models the interaction between system components and connectors as to indicate the activities of a system. Physical View: Models the placement of the collection of components and connectors of a system within a physical environment. Recently I had to use the concept of abstraction to express an idea for implementing a new security framework on an existing website. My concept would add session based management in order to properly secure and allow page access based on valid user credentials and last user activity.  I created a basic Process View by using UML diagrams to communicate the basic process flow of my changes in the application so that all of the projects stakeholders would be able to understand my idea. Additionally I created a Logical View on a whiteboard while conveying the process workflow with a few stakeholders to show how end-user will be affected by the new framework and gaining additional input about the design. After my Logical and Process Views were accepted I then started on creating a more detailed Development View in order to map how the system will be built based on the concept of components and connections based on the previously defined interactions. I really did not need to create a Physical view for this idea because we were updating an existing system that was already deployed based on an existing Physical View. What do you think about the use of abstraction in the development of software architecture? Please let me know.

    Read the article

  • H1 Visa interview tips–What you must know before attending the interview?

    - by Gopinath
    USA’s H1 visa allows highly qualified professionals from other countries to work in America. Many IT professionals in India aspire to go to USA on H1 and work for their clients. Recently I had a chance to study H1 visa process to help one of my friends and I would like to share what I learned. With the assumption that your H1 petition is approved and you got an interview scheduled at US Embassy for your visa stamping, here are tips you must know before attending the interview Dress Code – Formals Say no to casuals or any fancy dress when you attend the interview. It’s not a party or friends home you are visiting. Consider H1 Visa interview as your job interview and dress up in formals. There is no option B for your, you must be in formals. A plain formal shirt with a matching pant is suggested for men. Tie and Suit would not be required, but if you are a professional at management level you can consider wearing suit. Women can wear either formal Salwar or formal pant-shirt. Avoid heavy jewellery, wear what is must as per your tradition or culture. Body Language -  Smile on your face Your body language reflects what you are and what’s going on in your mind. Don’t be nervous or restless, be relaxed and wear a beautiful smile on your face. A smile is a curve that sets everything straight. When you are called for the interview, greet the interviewer with a beautiful smile. Say Good Morning/Afternoon/Evening depending on time you are visiting them. Whenever appropriate say Thank You. Generally American professionals are very friendly people and they reciprocate for your greetings. Make sure that you make them comfortable to start the interview. Carry original documents in a separate folder I don’t want to talk much about the documents that are required for your H1B interview as it’s big subject on it’s own and it requires a separate post. I assume that your consultant or employer helped you in gathering all the required documents like – petition, DS 160 forms, education & job related documents, resume, interview call letters, client letters, etc. For all the documents you are going to submit at the interview make sure that you have originals in a separate folder.  If required interviewer may ask you show the originals of any of the document you submitted for visa processing. Don’t mix the original documents with the documents you need to submit for interview. Have a separate folder for them. For those who are going to stamping along with their spouse and children, they need to carry few extra original documents like – marriage certificate, marriage photos(30 numbers)/album, birth certificates, passports, education and profession related certificates of the spouse and children. Know your role & responsibilities The interviewer will ask you questions on your roles and responsibilities at client location. Be clear what is your day to day tasks at client place and prepared to face detailed questions on the same. When asked explain clearly and also make sure what you say is inline with what is mentioned in your petition and client invitation letter. At times they may ask you questions specific to the project/technology you are going to work. So doing some homework in this area will help you easily answer the questions. Failing to answer basic questions on your role & responsibilities may result in rejection. You work for your Employer at Client location but NOT FOR CLIENT One of the important things to keep in mind that you work for your employer and you are being deputed to client location on a work visa.  Your employer is going to be solely responsible for your salary, work, promotion, pay hikes or what so ever during your stay at USA. Your client will not be responsible for anything. Lets say you are employed with Company X in India and they are applying for H1B to work at your client(ex: Microsoft) in USA, you must keep in my mind that Microsoft is not your employer. Microsoft will not pay your salaries or responsible for any employment related activities. Company X will be solely responsible for all your employer related activities. If you don’t get this correctly and say to Visa interviewer that your client is responsible, then you may get into troubles. Know your client It’s always good to know the clients with whom you are going to work in USA and their business. If your client is a well know organisation then you may not get many questions from interviewer else you need to be well prepared to provide details like – nature of business, location, size of the organisation, etc.  Get to know the basic details about your client and be confident while providing those details to the interviewer. Also make sure that you never talk about any confidential details of your client projects and business. Revealing confidential details of your client may land your job itself in soup. Make sure that your spouse is also in sync with you If you’ve applied a H4 visa for your spouse along with your H1, make sure that spouse is in sync with you. Your spouse also should know the basic details of your job, your employer, client and location where you will be travelling. Your spouse should also be prepared to answers questions related to marriage, their profession(if working), kids, education, etc. Interviewers will try to asses your spouse communication skills, whereabouts while staying in USA and would they prefer to work USA or not. On H4, which is a dependent visa, your spouse is not allowed to work in USA and at any point your spouse should not show the intentions to search for work in USA. Less luggage more comfort You would have definitely heard that there are lot of restrictions on what you can carry along with you to an US Embassy while attending the interview. To be frank it’s not good to say there are many restrictions, but there are a hell a lot of restrictions. There are unbelievable restrictions and it’s for the safety of everyone. You are not allowed to carry mobile phones, CD/DVDs, USBs, bank cards, cameras, cosmetics, food(except baby food), water, wallets, backpacks, sealed covers, etc. Trust me most of the things we carry with us regularly every day are not allowed inside. As there are 100s of restrictions, it would be easier if you understand what you can carry along with you and just carry them alone. Ask your employer/consultant to provide you a checklist of items that you can carry. Most what you would require are H1B related documents provided by the employer/consultant Photographs All original documents supporting your H1B Passports Some cash for your travel expenses (avoid coins) Any important phone number / details written in a paper(like your cab driver number, etc.) If you carry restricted stuff then you will be stopped at security checks, you have to find people who can safely keep all the restricted items. Due to heavy restrictions in and around the US Embassy you will not find any  place to keep your luggage. So just carry the bare minimum things required so that you feel more comfortable. Useful Links THE U.S. NON IMMIGRANT VISA APPLICATION PROCESS U.S VISA SECURITY REGULATIONS GENERAL FAQS Hope this information is helpful to you and best of luck for your interview. Creative commons Image credit: Flickr/ alexfrance, vinothchandar. hughelectronic, architratan, striatic

    Read the article

  • Errors when trying to compile the driver for the rtl8192su wireless adapter

    - by Tom Brito
    I have a wireless to usb adapter, and I'm having some trouble to install the drivers on Ubuntu. First of all, the readme says to use the make command, and I already got errors: $ make make[1]: Entering directory `/usr/src/linux-headers-2.6.35-22-generic' CC [M] /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.o /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c: In function ‘rtl8192_usb_probe’: /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c:12325: error: ‘struct net_device’ has no member named ‘open’ /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c:12326: error: ‘struct net_device’ has no member named ‘stop’ /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c:12327: error: ‘struct net_device’ has no member named ‘tx_timeout’ /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c:12328: error: ‘struct net_device’ has no member named ‘do_ioctl’ /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c:12329: error: ‘struct net_device’ has no member named ‘set_multicast_list’ /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c:12330: error: ‘struct net_device’ has no member named ‘set_mac_address’ /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c:12331: error: ‘struct net_device’ has no member named ‘get_stats’ /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.c:12332: error: ‘struct net_device’ has no member named ‘hard_start_xmit’ make[2]: *** [/home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u/r8192U_core.o] Error 1 make[1]: *** [_module_/home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/HAL/rtl8192u] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-2.6.35-22-generic' make: *** [all] Error 2 /home/wellington/Desktop/rtl8192su_linux_2.4_2.6.0003.0301.2010/ is the path where I copied the drivers on my computer. Any idea how to solve this? (I don't even know what the error is...) update: sudo lshw -class network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:01:00.0 logical name: eth0 version: 03 serial: 78:e3:b5:e7:5f:6e size: 10MB/s capacity: 1GB/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10MB/s resources: irq:42 ioport:d800(size=256) memory:fbeff000-fbefffff memory:faffc000-faffffff memory:fbec0000-fbedffff *-network DISABLED description: Wireless interface physical id: 2 logical name: wlan0 serial: 00:26:18:a1:ae:64 capabilities: ethernet physical wireless configuration: broadcast=yes multicast=yes wireless=802.11b/g sudo lspci 00:00.0 Host bridge: Intel Corporation Core Processor DRAM Controller (rev 18) 00:02.0 VGA compatible controller: Intel Corporation Core Processor Integrated Graphics Controller (rev 18) 00:16.0 Communication controller: Intel Corporation 5 Series/3400 Series Chipset HECI Controller (rev 06) 00:1a.0 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1b.0 Audio device: Intel Corporation 5 Series/3400 Series Chipset High Definition Audio (rev 06) 00:1c.0 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 1 (rev 06) 00:1c.2 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 3 (rev 06) 00:1d.0 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev a6) 00:1f.0 ISA bridge: Intel Corporation 5 Series Chipset LPC Interface Controller (rev 06) 00:1f.2 SATA controller: Intel Corporation 5 Series/3400 Series Chipset 6 port SATA AHCI Controller (rev 06) 00:1f.3 SMBus: Intel Corporation 5 Series/3400 Series Chipset SMBus Controller (rev 06) 01:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 02:00.0 FireWire (IEEE 1394): VIA Technologies, Inc. VT6315 Series Firewire Controller (rev 01) sudo lsusb Bus 002 Device 003: ID 0bda:0158 Realtek Semiconductor Corp. USB 2.0 multicard reader Bus 002 Device 002: ID 8087:0020 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 001 Device 004: ID 045e:00f9 Microsoft Corp. Wireless Desktop Receiver 3.1 Bus 001 Device 003: ID 0b05:1786 ASUSTek Computer, Inc. Bus 001 Device 002: ID 8087:0020 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub

    Read the article

  • Hardware wireless switch has no effect after suspend and 13.10 upgrade

    - by blaineh
    This seems to be a fairly chronic problem, as shown by the following questions: How do I fix a "Wireless is disabled by hardware switch" error? Wireless disabled by hardware switch "Wireless disabled by hardware switch" after suspend and other hardware buttons ineffective - how can I solve this? but no good solutions have been found! Wireless works fine after a reboot, but after a suspend the hardware switch (for my laptop this is f12) has no effect on the wireless, it is just permanently off, and shows that it is with a red LED. All My rfkill list all reads: 0: phy0: Wireless LAN Soft blocked: no Hard blocked: yes 1: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: yes Any combination with rfkill <un>block wifi doesn't work, although one time first blocking then unblocking actually turned it on again. sudo lshw -C network reads: *-network DISABLED description: Wireless interface product: AR9285 Wireless Network Adapter (PCI-Express) vendor: Qualcomm Atheros physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 01 serial: 78:e4:00:65:2e:3f width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.11.0-12-generic firmware=N/A ip=155.99.215.79 latency=0 link=yes multicast=yes wireless=IEEE 802.11bgn resources: irq:17 memory:90100000-9010ffff *-network DISABLED description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 02 serial: c8:0a:a9:89:b4:30 size: 10Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:42 ioport:2000(size=256) memory:90010000-90010fff memory:90000000-9000ffff memory:90020000-9002ffff Also, adding a /etc/pm/sleep.d/brcm.sh file as recommended here simply prevents the laptop from suspending at all, which of course is no good. This question has an answer urging to install the original driver, but it wasn't an "accepted answer" so I'd rather not take a chance on it. Also I'll admit I'm a bit lost on that and would like help doing so with the specific information I've given. xev shows that no internal event is triggered for my wireless switch (f12), but other function keys also acting as hardware switches work fine. I would be happy to provide more information, so long as you're willing to help me find it for you! This is a very annoying bug. I have a Compaq Presario CQ62. Edit. I just tried to reload bios defaults (or something) as shown by this video. Didn't work. Edit. I tried the contents of this answer, and it didn't work. Edit. I made a pastebin of dmesg. I couldn't even begin to understand the contents. Edit. Output of lspci | grep Network: 02:00.0 Network controller: Qualcomm Atheros AR9285 Wireless Network Adapter (PCI-Express) (rev 01)

    Read the article

  • Organization &amp; Architecture UNISA Studies &ndash; Chap 6

    - by MarkPearl
    Learning Outcomes Discuss the physical characteristics of magnetic disks Describe how data is organized and accessed on a magnetic disk Discuss the parameters that play a role in the performance of magnetic disks Describe different optical memory devices Magnetic Disk The way data is stored on and retried from magnetic disks Data is recorded on and later retrieved form the disk via a conducting coil named the head (in many systems there are two heads) The writ mechanism exploits the fact that electricity flowing through a coil produces a magnetic field. Electric pulses are sent to the write head, and the resulting magnetic patterns are recorded on the surface below with different patterns for positive and negative currents The physical characteristics of a magnetic disk   Summarize from book   The factors that play a role in the performance of a disk Seek time – the time it takes to position the head at the track Rotational delay / latency – the time it takes for the beginning of the sector to reach the head Access time – the sum of the seek time and rotational delay Transfer time – the time it takes to transfer data RAID The rate of improvement in secondary storage performance has been considerably less than the rate for processors and main memory. Thus secondary storage has become a bit of a bottleneck. RAID works on the concept that if one disk can be pushed so far, additional gains in performance are to be had by using multiple parallel components. Points to note about RAID… RAID is a set of physical disk drives viewed by the operating system as a single logical drive Data is distributed across the physical drives of an array in a scheme known as striping Redundant disk capacity is used to store parity information, which guarantees data recoverability in case of a disk failure (not supported by RAID 0 or RAID 1) Interesting to note that the increase in the number of drives, increases the probability of failure. To compensate for this decreased reliability RAID makes use of stored parity information that enables the recovery of data lost due to a disk failure.   The RAID scheme consists of 7 levels…   Category Level Description Disks Required Data Availability Large I/O Data Transfer Capacity Small I/O Request Rate Striping 0 Non Redundant N Lower than single disk Very high Very high for both read and write Mirroring 1 Mirrored 2N Higher than RAID 2 – 5 but lower than RAID 6 Higher than single disk Up to twice that of a signle disk for read Parallel Access 2 Redundant via Hamming Code N + m Much higher than single disk Highest of all listed alternatives Approximately twice that of a single disk Parallel Access 3 Bit interleaved parity N + 1 Much higher than single disk Highest of all listed alternatives Approximately twice that of a single disk Independent Access 4 Block interleaved parity N + 1 Much higher than single disk Similar to RAID 0 for read, significantly lower than single disk for write Similar to RAID 0 for read, significantly lower than single disk for write Independent Access 5 Block interleaved parity N + 1 Much higher than single disk Similar to RAID 0 for read, lower than single disk for write Similar to RAID 0 for read, generally  lower than single disk for write Independent Access 6 Block interleaved parity N + 2 Highest of all listed alternatives Similar to RAID 0 for read; lower than RAID 5 for write Similar to RAID 0 for read, significantly lower than RAID 5  for write   Read page 215 – 221 for detailed explanation on RAID levels Optical Memory There are a variety of optical-disk systems available. Read through the table on page 222 – 223 Some of the devices include… CD CD-ROM CD-R CD-RW DVD DVD-R DVD-RW Blue-Ray DVD Magnetic Tape Most modern systems use serial recording – data is lade out as a sequence of bits along each track. The typical recording used in serial is referred to as serpentine recording. In this technique when data is being recorded, the first set of bits is recorded along the whole length of the tape. When the end of the tape is reached the heads are repostioned to record a new track, and the tape is again recorded on its whole length, this time in the opposite direction. That process continued back and forth until the tape is full. To increase speed, the read-write head is capable of reading and writing a number of adjacent tracks simultaneously. Data is still recorded serially along individual tracks, but blocks in sequence are stored on adjacent tracks as suggested. A tape drive is a sequential access device. Magnetic tape was the first kind of secondary memory. It is still widely used as the lowest-cost, slowest speed member of the memory hierarchy.

    Read the article

  • How to use more than 3 virtual disks in Linux using CentOS and XenServer

    - by 010110110101
    I've attached 5 virtual disks to a Virtual Machine in Citrix XenServer. The VM has the xs-tools installed. Initially it said that it couldn't add so many disks. After I installed the xs-tools, it let me add all the disks. But /dev doesn't show all the disks. It shows these: /dev/xvda /dev/xvdb /dev/xvdc /dev/cdrom Perhaps it is bound by the limits of an IDE bus? (3 disks + CD-ROM) If so, how does one change the VM to use SCSI? Edit: According to the documentation: 2.6.3. VM Block Devices In the PV Linux case, block devices are passed through as PV devices. XenServer does not attempt to emulate SCSI or IDE, but instead provides a more suitable interface in the virtual environment in the form of xvd* devices. It is also possible to get an sd* device using the same mechanism, where the PV driver inside the VM takes over the SCSI device namespace. This is not desirable so it is best to use xvd* where possible for PV guests (this is the default for Debian and RHEL). For Windows or other fully virtualized guests, XenServer emulates an IDE bus in the form of an hd* device. When using Windows, installing the Citrix Tools for Virtual Machines installs a special PV driver that works in a similar way to Linux, except in the fully virtualized environment. Still, with 5 virtual disks attached, I don't see the other xvd devices. Edit #2: (attached requested info) Host Machine: XenServer 6.1 Linux version 2.6.32.43-0.4.1.xs1.6.10.777.170770xen (geeko@buildhost) (gcc version 4.1.2 20080704 (Red Hat 4.1.2-51)) #1 SMP Wed Apr 17 05:52:03 EDT 2013 Guest Machine: CentOS release 6.4 (Final) Linux version 2.6.32-358.6.2.el6.x86_64 ([email protected]) (gcc version 4.4.7 20120313 (Red Hat 4.4.7-3) (GCC) ) #1 SMP Thu May 16 20:59:36 UTC 2013 Output of 'fdisk -l' on Guest Machine: Note, the disk beyond the first 3 attached are not displaying -- there should be 4 100GB disks. (There are a total of 5 disks displayed in XenCenter -- 16GB, 100GB, 100GB, 100GB, 100GB) Disk /dev/xvdb: 107.4 GB, 107374182400 bytes 255 heads, 63 sectors/track, 13054 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xfb6c95b9 Device Boot Start End Blocks Id System /dev/xvdb1 1 13054 104856223+ 83 Linux Disk /dev/xvda: 17.2 GB, 17179869184 bytes 255 heads, 63 sectors/track, 2088 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000e5f41 Device Boot Start End Blocks Id System /dev/xvda1 * 1 64 512000 83 Linux Partition 1 does not end on cylinder boundary. /dev/xvda2 64 2089 16264192 8e Linux LVM Disk /dev/xvdc: 107.4 GB, 107374182400 bytes 255 heads, 63 sectors/track, 13054 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xed249ced Device Boot Start End Blocks Id System /dev/xvdc1 1 13054 104856223+ 83 Linux Disk /dev/mapper/vg_blue-lv_root: 14.6 GB, 14571012096 bytes 255 heads, 63 sectors/track, 1771 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_blue-lv_swap: 2080 MB, 2080374784 bytes 255 heads, 63 sectors/track, 252 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 I see that the Linux versions say SMP. The Guest VM doesn't say "xen" in the name. However, I have already run yum install kernel-xen. Could be a clue?

    Read the article

  • lvm disappeared after disc replacement on raid10

    - by user142295
    here my problem: I am running ubuntu 12.04 on a raid10 (4 disks), on top of which I installed an lvm with two volume groups (one for /, one for /home). The layout of the disks are as follows: Disk /dev/sda: 1500.3 GB, 1500301910016 bytes 255 heads, 63 sectors/track, 182401 cylinders, total 2930277168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0003f3b6 Device Boot Start End Blocks Id System /dev/sda1 * 63 481949 240943+ 83 Linux /dev/sda2 481950 2910640634 1455079342+ fd Linux raid autodetect /dev/sda3 2910640635 2930272064 9815715 82 Linux swap / Solaris Disk /dev/sdb: 1500.3 GB, 1500301910016 bytes 255 heads, 63 sectors/track, 182401 cylinders, total 2930277168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00069785 Device Boot Start End Blocks Id System /dev/sdb1 63 2910158684 1455079311 fd Linux raid autodetect /dev/sdb2 2910158685 2930272064 10056690 82 Linux swap / Solaris Disk /dev/sdc: 1500.3 GB, 1500301910016 bytes 255 heads, 63 sectors/track, 182401 cylinders, total 2930277168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sdc1 63 2910158684 1455079311 fd Linux raid autodetect /dev/sdc2 2910158685 2930272064 10056690 82 Linux swap / Solaris Disk /dev/sdd: 1500.3 GB, 1500301910016 bytes 255 heads, 63 sectors/track, 182401 cylinders, total 2930277168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000f14de Device Boot Start End Blocks Id System /dev/sdd1 63 2910158684 1455079311 fd Linux raid autodetect /dev/sdd2 2910158685 2930272064 10056690 82 Linux swap / Solaris The first disk (/dev/sda) contains the /boot partition on /dev/sda1. I use grub2 to boot the system off this partition. On top of this raid10 I installed two volume groups, one for /, one for /home. This system worked well, I even exchanged two disks during the last two years. It always worked. But not this time. For the first time, /dev/sda broke. I do not know if this is an issue – I know I would have struggled anyways to overcome the problem with /boot installed on that disk and grub2 installed on the mbr of /dev/sda. Anyways, I did what I always did: start knoppix fire up the raid sudo mdadm --examine -scan which returns ARRAY /dev/md127 UUID=0dbf4558:1a943464:132783e8:19cdff95 start it up sudo mdadm --assemble /dev/md127 fail the failing disk (smart event) sudo mdadm /dev/md127 --fail /dev/sda2 remove the failing disk sudo mdadm /dev/md127 --remove /dev/sda2 stop the raid sudo mdadm -S /dev/md127 take out the disk replace it with a new one create the same partitions as on the failling one add it to the raid sudo mdadm --assemble /dev/md127 sudo mdadm /dev/md127 --add /dev/sda2 wait 4 hours All looks fine: cat /proc/mdstat returns: Personalities : [raid10] md127 : active raid10 sda2[0] sdd1[3] sdc1[2] sdb1[1] 2910158464 blocks 64K chunks 2 near-copies [4/4] [UUUU] unused devices: <none> and sudo mdadm --detail /dev/md127 returns /dev/md127: Version : 0.90 Creation Time : Wed Jun 10 13:08:46 2009 Raid Level : raid10 Array Size : 2910158464 (2775.34 GiB 2980.00 GB) Used Dev Size : 1455079232 (1387.67 GiB 1490.00 GB) Raid Devices : 4 Total Devices : 4 Preferred Minor : 127 Persistence : Superblock is persistent Update Time : Thu Mar 21 16:27:40 2013 State : clean Active Devices : 4 Working Devices : 4 Failed Devices : 0 Spare Devices : 0 Layout : near=2 Chunk Size : 64K UUID : 0dbf4558:1a943464:132783e8:19cdff95 (local to host Microknoppix) Events : 0.4824680 Number Major Minor RaidDevice State 0 8 2 0 active sync /dev/sda2 1 8 17 1 active sync /dev/sdb1 2 8 33 2 active sync /dev/sdc1 3 8 49 3 active sync /dev/sdd1 However, there is no trace of the volume groups. Rebooting into knoppix does not help Restarting the old system (I actually replugged and re-added the failing disk for that – the system begins to start, but then fails to see the / partition – no wonder if the volume group is gone) does not help. sudo vgscan, sudo vgdisplay, sudo lvs, sudo lvdisplay, sudo vgscan –mknodes all returned No volume groups found. I am completely at a loss. Can anyone tell me if and how I can recover my data? Thanks in advance!

    Read the article

  • Upgraded to 12.04 now wifi doesn't work

    - by Benito Kestelman
    My laptop's wifi stopped working when I upgraded to Ubuntu 12.04 (wired works). I just reinstalled 12.04 over my old 12.04 on which wifi didn't work either in an attempt to restore any settings I may have accidentally changed, but it still doesn't work. I also used a wired connection to install updates in case this bug has been fixed, but it has not. Here is the result of sudo lshw -class network: *-network description: Wireless interface product: Centrino Wireless-N + WiMAX 6150 vendor: Intel Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 67 serial: 40:25:c2:5f:5b:f4 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwlwifi driverversion=3.2.0-29-generic-pae firmware=41.28.5.1 build 33926 latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:51 memory:de800000-de801fff *-network description: Ethernet interface product: AR8151 v2.0 Gigabit Ethernet vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 logical name: eth0 version: c0 serial: 14:da:e9:c0:da:78 capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vpd bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=atl1c driverversion=1.0.1.0-NAPI firmware=N/A latency=0 link=no multicast=yes port=twisted pair resources: irq:54 memory:dd400000-dd43ffff ioport:a000(size=128) Here is rfkill list all: 0: phy0: Wireless LAN Soft blocked: no Hard blocked: no 1: asus-wlan: Wireless LAN Soft blocked: no Hard blocked: no 2: asus-wimax: WiMAX Soft blocked: no Hard blocked: no lsusb: Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 003: ID 8087:07d6 Intel Corp. Bus 001 Device 004: ID 13d3:5710 IMC Networks Bus 002 Device 003: ID 045e:0745 Microsoft Corp. Nano Transceiver v1.0 for Bluetooth Bus 003 Device 003: ID 0781:5530 SanDisk Corp. Cruzer lspci: 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 00:16.0 Communication controller: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 (rev 04) 00:1a.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 (rev 05) 00:1b.0 Audio device: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller (rev 05) 00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) 00:1c.1 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 2 (rev b5) 00:1c.3 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 4 (rev b5) 00:1c.5 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 6 (rev b5) 00:1d.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 (rev 05) 00:1f.0 ISA bridge: Intel Corporation HM65 Express Chipset Family LPC Controller (rev 05) 00:1f.2 SATA controller: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller (rev 05) 02:00.0 Network controller: Intel Corporation Centrino Wireless-N + WiMAX 6150 (rev 67) 03:00.0 USB controller: ASMedia Technology Inc. ASM1042 SuperSpeed USB Host Controller 04:00.0 Ethernet controller: Atheros Communications Inc. AR8151 v2.0 Gigabit Ethernet (rev c0)

    Read the article

  • MOSSLover Lives On&hellip;

    - by MOSSLover
    A while back, maybe 6 months, I got some bad news about 2010.  Microsoft was removing Office from the MOSS equivalent of 2010, so basically my alias would be obsolete the second 2010 caught on in the community.  I thought about it for some time.  I had some discussions with friends in the community.  I even noticed that the MOSSMan changed his twitter id.  I started my blog around a WSS 3.0 project when I worked for LRS in there St. Louis Office in February/March 2007.  So I think it’s fitting to keep the name, because my community involvement centers around 2007.  My first ever speaking ordeal was at the Kansas City Office Geeks meeting in November of 2007 on Disaster Recovery where about three people attended.  The first user group meeting I ever attended was around the month of June 2007 at the KC .Net User Group about two weeks after my braces were installed.  It’s definitely fitting to say that 2007 paved the way for everything that happened in the past 2/2 1/2 years.  If anyone asks what MOSSLover means I added a description on twitter and I also added my name.  I added my name for other reasons, because I’m sick of people thinking I am the guy in the photo.  Also, I’d like people to recognize me for who I am.  Everyone should expect less of the hat in the upcoming year and more of my hair.  I’ve taken a vow to wear the hat less and less this year.  I am sick of buying hats, plus I want to move forward to gain more self confidence.  The hat does not really help.  I will still wear a t-shirt and jeans in most of my presentations.  That is who I am and it will not change any time soon.  If you expect to see me in a skirt good luck with that as it won’t be happening unless I am forced at gun point.  I hope you guys have a good weekend.  Later all… Technorati Tags: MOSSLover,Cardinal's Hat,Becky Isserman

    Read the article

  • "The connection has timed out" - Please help!

    - by gon
    I recently installed a fresh Ubuntu 12.04 LTS on a desktop, and the installation itself was successful (other than 'grub rescue' issue that I encountered but fixed) but this connection problem is really giving me a headache. Symptoms: 1. When I open the FireFox browser and try to connect to a website, it just hangs for a while saying "Connecting..." but eventually loads an error page "The connection has timed out". 2. It's not a browser problem (and I tried setting ipv6 thing to "true" at about:config) because running "sudo apt-get install [some-random-package]" at terminal fails ("E: Unable to locate package [package]") too. All other operations that need internet access are not working. 3. I certainly see a wired network (called "eth1") at the Network Manager, and it says "Connection Established" after disconnecting and then connecting again. I have tried almost everything that could be found from google search results still no luck. Their problems slightly differ from mine or the solutions just don't work. By the way it didn't have internet access when installing Ubuntu 12.04. (I ignored the message that I need internet to install Ubuntu) Could this be a problem? I'm sorry I don't remember if internet worked or not on the previous version of Ubuntu. :( I would really appreciate your help... I don't even know what more to do if this fails too.. Thanks!! Thanks for your comment. Here is the result of ifconfig: eth0 Link encap:Ethernet HWaddr 78:ac:c0:3d:b2:b9 inet addr:10.10.65.185 Bcast:10.10.65.255 Mask:255.255.255.0 inet6 addr: fe80::7aac:c0ff:fe3d:b2b9/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:3907 errors:0 dropped:0 overruns:0 frame:0 TX packets:771 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:393118 (393.1 KB) TX bytes:73472 (73.4 KB) Interrupt:16 eth1 Link encap:Ethernet HWaddr 78:ac:c0:3d:b2:b8 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:17 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:4 errors:0 dropped:0 overruns:0 frame:0 TX packets:4 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:204 (204.0 B) TX bytes:204 (204.0 B) route -n: Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 0.0.0.0 10.10.65.1 0.0.0.0 UG 0 0 0 eth0 10.10.65.0 0.0.0.0 255.255.255.0 U 1 0 0 eth0 169.254.0.0 0.0.0.0 255.255.0.0 U 1000 0 0 eth0 /etc/resolv.conf: # Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8) # DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN nameserver 8.8.8.8 nameserver 8.8.4.4 nameserver 10.81.1.8 nameserver 10.1.2.10 nameserver 127.0.0.1 search yamatake.local /etc/network/interfaces: auto lo iface lo inet loopback #auto eth0 #iface eth0 inet dhcp #auto eth1 #iface eth1 inet dhcp And I'll also include the result of 'sudo lshw -C network' in case it might help: *-network description: Ethernet interface product: NetXtreme BCM5764M Gigabit Ethernet PCIe vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: eth0 version: 10 serial: 78:ac:c0:3d:b2:b9 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.121 duplex=full firmware=5764m-v3.35 ip=10.10.65.185 latency=0 link=yes multicast=yes port=twisted pair speed=100Mbit/s resources: irq:93 memory:fc000000-fc00ffff *-network description: Ethernet interface product: NetXtreme BCM5764M Gigabit Ethernet PCIe vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:01:00.0 logical name: eth1 version: 10 serial: 78:ac:c0:3d:b2:b8 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.121 duplex=full firmware=5764m-v3.35 latency=0 link=no multicast=yes port=twisted pair speed=100Mbit/s resources: irq:94 memory:fb000000-fb00ffff

    Read the article

  • In a pinch, is it worthwhile to run a bootable USB drive for my primary PC for an extended period?

    - by jason
    My hard drive has crashed, and I won't be able to buy a new one for a month or two. I've got a 16GB USB 3.0 flash drive that I'd like to have running a persistent ubuntu or ubuntu gnome distro. While it's not the best solution, is it a solution, or is it just a good way to wear out a flash drive? I plan on mostly storing things in Google Drive, so other than wearing out the flash drive, are there any risks involved?

    Read the article

  • How to run a bootable USB drive as my primary PC for an extended period?

    - by jason
    My hard drive has crashed, and I won't be able to buy a new one for a month or two. I've got a 16GB USB 3.0 flash drive that I'd like to have running a persistent ubuntu or ubuntu gnome distro. While it's not the best solution, is it a solution, or is it just a good way to wear out a flash drive? I plan on mostly storing things in Google Drive, so other than wearing out the flash drive, are there any risks involved?

    Read the article

  • Something very strange with network

    - by Rodnower
    Hello, I have Windows 7 and I have very strange thing with my network. Some time I was connected through wireless router and my IP was 192.168.2.103, router's IP was 192.168.2.1 and some other IP was 192.168.2.100. The last I get from page "active DHCP clients" of web interface of the router and from "wireless clients" I may to see that 192.168.2.100 not (!) belong to my MAC address. Router build by EDimax. So after that I disabled wireless function of the router and restarted it. In this time I had not ping to 192.168.2.1. Also I had not any other connection, not wireless nor cable, but (!) I still had ping to 192.168.2.100 and I not understand what this voodoo is... C:\Users\Andrey>ping 192.168.2.100 Pinging 192.168.2.100 with 32 bytes of data: Reply from 192.168.2.100: bytes=32 time<1ms TTL=128 Reply from 192.168.2.100: bytes=32 time<1ms TTL=128 Reply from 192.168.2.100: bytes=32 time<1ms TTL=128 Reply from 192.168.2.100: bytes=32 time<1ms TTL=128 Ping statistics for 192.168.2.100: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms This is what I had: C:\Users\Andrey>ipconfig /all Windows IP Configuration Host Name . . . . . . . . . . . . : Andrey-PC Primary Dns Suffix . . . . . . . : Node Type . . . . . . . . . . . . : Hybrid IP Routing Enabled. . . . . . . . : No WINS Proxy Enabled. . . . . . . . : No Wireless LAN adapter Wireless Network Connection 3: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Microsoft Virtual WiFi Miniport Adapter #2 Physical Address. . . . . . . . . : 06-1D-7D-40-61-EB DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes Wireless LAN adapter Wireless Network Connection: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Gigabyte GN-WS50G (mini) PCI-E WLAN Card Physical Address. . . . . . . . . : 00-1D-7D-40-61-EB DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes Ethernet adapter Local Area Connection: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Marvell Yukon 88E8055 PCI-E Gigabit Ethernet Controller Physical Address. . . . . . . . . : 00-1B-24-B6-09-91 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes C:\Users\Andrey>arp -a -v Interface: 127.0.0.1 --- 0x1 Internet Address Physical Address Type 224.0.0.22 static 239.255.255.250 static Interface: 0.0.0.0 --- 0xffffffff Internet Address Physical Address Type 192.168.2.1 00-0e-2e-d2-8c-af invalid 192.168.2.255 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.252 01-00-5e-00-00-fc static 239.255.255.250 01-00-5e-7f-ff-fa static 255.255.255.255 ff-ff-ff-ff-ff-ff static Interface: 0.0.0.0 --- 0xffffffff Internet Address Physical Address Type 192.168.2.1 00-0e-2e-ff-f1-f6 dynamic 192.168.2.101 00-27-19-bc-8b-9c dynamic 192.168.2.102 00-16-e6-6c-ae-d4 dynamic 192.168.2.255 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.252 01-00-5e-00-00-fc static 239.255.255.250 01-00-5e-7f-ff-fa static 255.255.255.255 ff-ff-ff-ff-ff-ff static Interface: 0.0.0.0 --- 0xffffffff Internet Address Physical Address Type 224.0.0.22 01-00-5e-00-00-16 static 255.255.255.255 ff-ff-ff-ff-ff-ff static C:\Users\Andrey>route print =========================================================================== Interface List 14...06 1d 7d 40 61 eb ......Microsoft Virtual WiFi Miniport Adapter #2 13...00 1d 7d 40 61 eb ......Gigabyte GN-WS50G (mini) PCI-E WLAN Card 11...00 1b 24 b6 09 91 ......Marvell Yukon 88E8055 PCI-E Gigabit Ethernet Controller 1...........................Software Loopback Interface 1 =========================================================================== IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 =========================================================================== Persistent Routes: None IPv6 Route Table =========================================================================== Active Routes: If Metric Network Destination Gateway 1 306 ::1/128 On-link 1 306 ff00::/8 On-link =========================================================================== Persistent Routes: None Only after reboot I lost ping to there: C:\Users\Andrey>ping 192.168.2.100 Pinging 192.168.2.100 with 32 bytes of data: PING: transmit failed. General failure. PING: transmit failed. General failure. PING: transmit failed. General failure. PING: transmit failed. General failure. Ping statistics for 192.168.2.100: Packets: Sent = 4, Received = 0, Lost = 4 (100% loss), So what this mysterious cache is? Thank you for ahead.

    Read the article

  • How to analyze 'dbcc memorystatus' result in SQL Server 2008

    - by envykok
    Currently i am facing a sql memory pressure issue. i have run 'dbcc memorystatus', here is part of my result: Memory Manager KB VM Reserved 23617160 VM Committed 14818444 Locked Pages Allocated 0 Reserved Memory 1024 Reserved Memory In Use 0 Memory node Id = 0 KB VM Reserved 23613512 VM Committed 14814908 Locked Pages Allocated 0 MultiPage Allocator 387400 SinglePage Allocator 3265000 MEMORYCLERK_SQLBUFFERPOOL (node 0) KB VM Reserved 16809984 VM Committed 14184208 Locked Pages Allocated 0 SM Reserved 0 SM Committed 0 SinglePage Allocator 0 MultiPage Allocator 408 MEMORYCLERK_SQLCLR (node 0) KB VM Reserved 6311612 VM Committed 141616 Locked Pages Allocated 0 SM Reserved 0 SM Committed 0 SinglePage Allocator 1456 MultiPage Allocator 20144 CACHESTORE_SQLCP (node 0) KB VM Reserved 0 VM Committed 0 Locked Pages Allocated 0 SM Reserved 0 SM Committed 0 SinglePage Allocator 3101784 MultiPage Allocator 300328 Buffer Pool Value Committed 1742946 Target 1742946 Database 1333883 Dirty 940 In IO 1 Latched 18 Free 89 Stolen 408974 Reserved 2080 Visible 1742946 Stolen Potential 1579938 Limiting Factor 13 Last OOM Factor 0 Page Life Expectancy 5463 Process/System Counts Value Available Physical Memory 258572288 Available Virtual Memory 8771398631424 Available Paging File 16030617600 Working Set 15225597952 Percent of Committed Memory in WS 100 Page Faults 305556823 System physical memory high 1 System physical memory low 0 Process physical memory low 0 Process virtual memory low 0 Procedure Cache Value TotalProcs 11382 TotalPages 430160 InUsePages 28 Can you lead me to analyze this result ? Is it a lot execute plan have been cached causing the memory issue or other reasons?

    Read the article

  • jQuery "Autcomplete" plugin is messing up the order of my data

    - by Max Williams
    I'm using Jorn Zaefferer's Autocomplete plugin on a couple of different pages. In both instances, the order of displayed strings is a little bit messed up. Example 1: array of strings: basically they are in alphabetical order except for General Knowledge which has been pushed to the top: General Knowledge,Art and Design,Business Studies,Citizenship,Design and Technology,English,Geography,History,ICT,Mathematics,MFL French,MFL German,MFL Spanish,Music,Physical Education,PSHE,Religious Education,Science,Something Else Displayed strings: General Knowledge,Geography,Art and Design,Business Studies,Citizenship,Design and Technology,English,History,ICT,Mathematics,MFL French,MFL German,MFL Spanish,Music,Physical Education,PSHE,Religious Education,Science,Something Else Note that Geography has been pushed to be the second item, after General Knowledge. The rest are all fine. Example 2: array of strings: as above but with Cross-curricular instead of General Knowledge. Cross-curricular,Art and Design,Business Studies,Citizenship,Design and Technology,English,Geography,History,ICT,Mathematics,MFL French,MFL German,MFL Spanish,Music,Physical Education,PSHE,Religious Education,Science,Something Else Displayed strings: Cross-curricular,Citizenship,Art and Design,Business Studies,Design and Technology,English,Geography,History,ICT,Mathematics,MFL French,MFL German,MFL Spanish,Music,Physical Education,PSHE,Religious Education,Science,Something Else Here, Citizenship has been pushed to the number 2 position. I've experimented a little, and it seems like there's a bug saying "put things that start with the same letter as the first item after the first item and leave the rest alone". Kind of mystifying. I've tried a bit of debugging by triggering alerts inside the autocomplete plugin code but everywhere i can see, it's using the correct order. it seems to be just when its rendered out that it goes wrong. Any ideas anyone? max

    Read the article

  • What does "cpuid level" means ? Asking just for curiosity

    - by ogzylz
    For example, I put just 2 core info of a 16 core machine. What does "cpuid level : 6" line means? If u can provide info about lines "bogomips : 5992.10" and "clflush size : 64" I will be appreciated processor : 0 vendor_id : GenuineIntel cpu family : 15 model : 6 model name : Intel(R) Xeon(TM) CPU 3.00GHz stepping : 8 cpu MHz : 2992.689 cache size : 4096 KB physical id : 0 siblings : 4 core id : 0 cpu cores : 2 fpu : yes fpu_exception : yes cpuid level : 6 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm syscall nx lm constant_tsc pni monitor ds_cpl vmx cid cx16 xtpr lahf_lm bogomips : 5992.10 clflush size : 64 cache_alignment : 128 address sizes : 40 bits physical, 48 bits virtual power management: processor : 1 vendor_id : GenuineIntel cpu family : 15 model : 6 model name : Intel(R) Xeon(TM) CPU 3.00GHz stepping : 8 cpu MHz : 2992.689 cache size : 4096 KB physical id : 1 siblings : 4 core id : 0 cpu cores : 2 fpu : yes fpu_exception : yes cpuid level : 6 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm syscall nx lm constant_tsc pni monitor ds_cpl vmx cid cx16 xtpr lahf_lm bogomips : 5985.23 clflush size : 64 cache_alignment : 128 address sizes : 40 bits physical, 48 bits virtual power management:

    Read the article

  • Installing Lubuntu 14.04.1 forcepae fails

    - by Rantanplan
    I tried to install Lubuntu 14.04.1 from a CD. First, I chose Try Lubuntu without installing which gave: ERROR: PAE is disabled on this Pentium M (PAE can potentially be enabled with kernel parameter "forcepae" ... Following the description on https://help.ubuntu.com/community/PAE, I used forcepae and tried Try Lubuntu without installing again. That worked fine. dmesg | grep -i pae showed: [ 0.000000] Kernel command line: file=/cdrom/preseed/lubuntu.seed boot=casper initrd=/casper/initrd.lz quiet splash -- forcepae [ 0.008118] PAE forced! On the live-CD session, I tried installing Lubuntu double clicking on the install button on the desktop. Here, the CD starts running but then stops running and nothing happens. Next, I rebooted and tried installing Lubuntu directly from the boot menu screen using forcepae again. After a while, I receive the following error message: The installer encountered an unrecoverable error. A desktop session will now be run so that you may investigate the problem or try installing again. Hitting Enter brings me to the desktop. For what errors should I search? And how? Finally, I rebooted once more and tried Check disc for defects with forcepae option; no errors have been found. Now, I am wondering how to find the error or whether it would be better to follow advice c in https://help.ubuntu.com/community/PAE: "Move the hard disk to a computer on which the processor has PAE capability and PAE flag (that is, almost everything else than a Banias). Install the system as usual but don't add restricted drivers. After the install move the disk back." Thanks for some hints! Perhaps some of the following can help: On Lubuntu 12.04: cat /proc/cpuinfo processor : 0 vendor_id : GenuineIntel cpu family : 6 model : 13 model name : Intel(R) Pentium(R) M processor 1.50GHz stepping : 6 microcode : 0x17 cpu MHz : 600.000 cache size : 2048 KB fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 2 wp : yes flags : fpu vme de pse tsc msr mce cx8 mtrr pge mca cmov clflush dts acpi mmx fxsr sse sse2 ss tm pbe up bts est tm2 bogomips : 1284.76 clflush size : 64 cache_alignment : 64 address sizes : 32 bits physical, 32 bits virtual power management: uname -a Linux humboldt 3.2.0-67-generic #101-Ubuntu SMP Tue Jul 15 17:45:51 UTC 2014 i686 i686 i386 GNU/Linux lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 12.04.5 LTS Release: 12.04 Codename: precise cpuid eax in eax ebx ecx edx 00000000 00000002 756e6547 6c65746e 49656e69 00000001 000006d6 00000816 00000180 afe9f9bf 00000002 02b3b001 000000f0 00000000 2c04307d 80000000 80000004 00000000 00000000 00000000 80000001 00000000 00000000 00000000 00000000 80000002 20202020 20202020 65746e49 2952286c 80000003 6e655020 6d756974 20295228 7270204d 80000004 7365636f 20726f73 30352e31 007a4847 Vendor ID: "GenuineIntel"; CPUID level 2 Intel-specific functions: Version 000006d6: Type 0 - Original OEM Family 6 - Pentium Pro Model 13 - Stepping 6 Reserved 0 Brand index: 22 [not in table] Extended brand string: " Intel(R) Pentium(R) M processor 1.50GHz" CLFLUSH instruction cache line size: 8 Feature flags afe9f9bf: FPU Floating Point Unit VME Virtual 8086 Mode Enhancements DE Debugging Extensions PSE Page Size Extensions TSC Time Stamp Counter MSR Model Specific Registers MCE Machine Check Exception CX8 COMPXCHG8B Instruction SEP Fast System Call MTRR Memory Type Range Registers PGE PTE Global Flag MCA Machine Check Architecture CMOV Conditional Move and Compare Instructions FGPAT Page Attribute Table CLFSH CFLUSH instruction DS Debug store ACPI Thermal Monitor and Clock Ctrl MMX MMX instruction set FXSR Fast FP/MMX Streaming SIMD Extensions save/restore SSE Streaming SIMD Extensions instruction set SSE2 SSE2 extensions SS Self Snoop TM Thermal monitor 31 reserved TLB and cache info: b0: unknown TLB/cache descriptor b3: unknown TLB/cache descriptor 02: Instruction TLB: 4MB pages, 4-way set assoc, 2 entries f0: unknown TLB/cache descriptor 7d: unknown TLB/cache descriptor 30: unknown TLB/cache descriptor 04: Data TLB: 4MB pages, 4-way set assoc, 8 entries 2c: unknown TLB/cache descriptor On Lubuntu 14.04.1 live-CD with forcepae: cat /proc/cpuinfo processor : 0 vendor_id : GenuineIntel cpu family : 6 model : 13 model name : Intel(R) Pentium(R) M processor 1.50GHz stepping : 6 microcode : 0x17 cpu MHz : 600.000 cache size : 2048 KB physical id : 0 siblings : 1 core id : 0 cpu cores : 1 apicid : 0 initial apicid : 0 fdiv_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 2 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 sep mtrr pge mca cmov clflush dts acpi mmx fxsr sse sse2 ss tm pbe bts est tm2 bogomips : 1284.68 clflush size : 64 cache_alignment : 64 address sizes : 36 bits physical, 32 bits virtual power management: uname -a Linux lubuntu 3.13.0-32-generic #57-Ubuntu SMP Tue Jul 15 03:51:12 UTC 2014 i686 i686 i686 GNU/Linux lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 14.04.1 LTS Release: 14.04 Codename: trusty cpuid CPU 0: vendor_id = "GenuineIntel" version information (1/eax): processor type = primary processor (0) family = Intel Pentium Pro/II/III/Celeron/Core/Core 2/Atom, AMD Athlon/Duron, Cyrix M2, VIA C3 (6) model = 0xd (13) stepping id = 0x6 (6) extended family = 0x0 (0) extended model = 0x0 (0) (simple synth) = Intel Pentium M (Dothan B1) / Celeron M (Dothan B1), 90nm miscellaneous (1/ebx): process local APIC physical ID = 0x0 (0) cpu count = 0x0 (0) CLFLUSH line size = 0x8 (8) brand index = 0x16 (22) brand id = 0x16 (22): Intel Pentium M, .13um feature information (1/edx): x87 FPU on chip = true virtual-8086 mode enhancement = true debugging extensions = true page size extensions = true time stamp counter = true RDMSR and WRMSR support = true physical address extensions = false machine check exception = true CMPXCHG8B inst. = true APIC on chip = false SYSENTER and SYSEXIT = true memory type range registers = true PTE global bit = true machine check architecture = true conditional move/compare instruction = true page attribute table = true page size extension = false processor serial number = false CLFLUSH instruction = true debug store = true thermal monitor and clock ctrl = true MMX Technology = true FXSAVE/FXRSTOR = true SSE extensions = true SSE2 extensions = true self snoop = true hyper-threading / multi-core supported = false therm. monitor = true IA64 = false pending break event = true feature information (1/ecx): PNI/SSE3: Prescott New Instructions = false PCLMULDQ instruction = false 64-bit debug store = false MONITOR/MWAIT = false CPL-qualified debug store = false VMX: virtual machine extensions = false SMX: safer mode extensions = false Enhanced Intel SpeedStep Technology = true thermal monitor 2 = true SSSE3 extensions = false context ID: adaptive or shared L1 data = false FMA instruction = false CMPXCHG16B instruction = false xTPR disable = false perfmon and debug = false process context identifiers = false direct cache access = false SSE4.1 extensions = false SSE4.2 extensions = false extended xAPIC support = false MOVBE instruction = false POPCNT instruction = false time stamp counter deadline = false AES instruction = false XSAVE/XSTOR states = false OS-enabled XSAVE/XSTOR = false AVX: advanced vector extensions = false F16C half-precision convert instruction = false RDRAND instruction = false hypervisor guest status = false cache and TLB information (2): 0xb0: instruction TLB: 4K, 4-way, 128 entries 0xb3: data TLB: 4K, 4-way, 128 entries 0x02: instruction TLB: 4M pages, 4-way, 2 entries 0xf0: 64 byte prefetching 0x7d: L2 cache: 2M, 8-way, sectored, 64 byte lines 0x30: L1 cache: 32K, 8-way, 64 byte lines 0x04: data TLB: 4M pages, 4-way, 8 entries 0x2c: L1 data cache: 32K, 8-way, 64 byte lines extended feature flags (0x80000001/edx): SYSCALL and SYSRET instructions = false execution disable = false 1-GB large page support = false RDTSCP = false 64-bit extensions technology available = false Intel feature flags (0x80000001/ecx): LAHF/SAHF supported in 64-bit mode = false LZCNT advanced bit manipulation = false 3DNow! PREFETCH/PREFETCHW instructions = false brand = " Intel(R) Pentium(R) M processor 1.50GHz" (multi-processing synth): none (multi-processing method): Intel leaf 1 (synth) = Intel Pentium M (Dothan B1), 90nm

    Read the article

  • Azure, don't give me multiple VMs, give me one elastic VM

    - by FransBouma
    Yesterday, Microsoft revealed new major features for Windows Azure (see ScottGu's post). It all looks shiny and great, but after reading most of the material describing the new features, I still find the overall idea behind all of it flawed: why should I care on how much VMs my web app runs? Isn't that a problem to solve for the Windows Azure engineers / software? And what if I need the file system, why can't I simply get a virtual filesystem ? To illustrate my point, let's use a real example: a product website with a customer system/database and next to it a support site with accompanying database. Both are written in .NET, using ASP.NET and use a SQL Server database each. The product website offers files to download by customers, very simple. You have a couple of options to host these websites: Buy a server, place it in a rack at an ISP and run the sites on that server Use 'shared hosting' with an ISP, which means your sites' appdomains are running on the same machine, as well as the files stored, and the databases are hosted in the same server as the other shared databases. Hire a VM, install your OS of choice at an ISP, and host the sites on that VM, basically the same as the first option, except you don't have a physical server At some cloud-vendor, either host the sites 'shared' or in a VM. See above. With all of those options, scalability is a problem, even the cloud-based ones, though not due to the same reasons: The physical server solution has the obvious problem that if you need more power, you need to buy a bigger server or more servers which requires you to add replication and other overhead Shared hosting solutions are almost always capped on memory usage / traffic and database size: if your sites get too big, you have to move out of the shared hosting environment and start over with one of the other solutions The VM solution, be it a VM at an ISP or 'in the cloud' at e.g. Windows Azure or Amazon, in theory allows scaling out by simply instantiating more VMs, however that too introduces the same overhead problems as with the physical servers: suddenly more than 1 instance runs your sites. If a cloud vendor offers its services in the form of VMs, you won't gain much over having a VM at some ISP: the main problems you have to work around are still there: when you spin up more than one VM, your application must be completely stateless at any moment, including the DB sub system, because what's in memory in instance 1 might not be in memory in instance 2. This might sounds trivial but it's not. A lot of the websites out there started rather small: they were perfectly runnable on a single machine with normal memory and CPU power. After all, you don't need a big machine to run a website with even thousands of users a day. Moving these sites to a multi-VM environment will cause a problem: all the in-memory state they use, all the multi-page transitions they use while keeping state across the transition, they can't do that anymore like they did that on a single machine: state is something of the past, you have to store every byte of state in either a DB or in a viewstate or in a cookie somewhere so with the next request, all state information is available through the request, as nothing is kept in-memory. Our example uses a bunch of files in a file system. Using multiple VMs will require that these files move to a cloud storage system which is mounted in each VM so we don't have to store the files on each VM. This might require different file paths, but this change should be minor. What's perhaps less minor is the maintenance procedure in place on the new type of cloud storage used: instead of ftp-ing into a VM, you might have to update the files using different ways / tools. All in all this makes moving an existing website which was written for an environment that's based around a VM (namely .NET with its CLR) overly cumbersome and problematic: it forces you to refactor your website system to be able to be used 'in the cloud', which is caused by the limited way how e.g. Windows Azure offers its cloud services: in blocks of VMs. Offer a scalable, flexible VM which extends with my needs Instead, cloud vendors should offer simply one VM to me. On that VM I run the websites, store my DB and my files. As it's a virtual machine, how this machine is actually ran on physical hardware (e.g. partitioned), I don't care, as that's the problem for the cloud vendor to solve. If I need more resources, e.g. I have more traffic to my server, way more visitors per day, the VM stretches, like I bought a bigger box. This frees me from the problem which comes with multiple VMs: I don't have any refactoring to do at all: I can simply build my website as if it runs on my local hardware server, upload it to the VM offered by the cloud vendor, install it on the VM and I'm done. "But that might require changes to windows!" Yes, but Microsoft is Windows. Windows Azure is their service, they can make whatever change to what they offer to make it look like it's windows. Yet, they're stuck, like Amazon, in thinking in VMs, which forces developers to 'think ahead' and gamble whether they would need to migrate to a cloud with multiple VMs in the future or not. Which comes down to: gamble whether they should invest time in code / architecture which they might never need. (YAGNI anyone?) So the VM we're talking about, is that a low-level VM which runs a guest OS, or is that VM a different kind of VM? The flexible VM: .NET's CLR ? My example websites are ASP.NET based, which means they run inside a .NET appdomain, on the .NET CLR, which is a VM. The only physical OS resource the sites need is the file system, however this too is accessed through .NET. In short: all the websites see is what .NET allows the websites to see, the world as the websites know it is what .NET shows them and lets them access. How the .NET appdomain is run physically, that's the concern of .NET, not mine. This begs the question why Windows Azure doesn't offer virtual appdomains? Or better: .NET environments which look like one machine but could be physically multiple machines. In such an environment, no change has to be made to the websites to migrate them from a local machine or own server to the cloud to get proper scaling: the .NET VM will simply scale with the need: more memory needed, more CPU power needed, it stretches. What it offers to the application running inside the appdomain is simply increasing, but not fragmented: all resources are available to the application: this means that the problem of how to scale is back to where it should be: with the cloud vendor. "Yeah, great, but what about the databases?" The .NET application communicates with the database server through a .NET ADO.NET provider. Where the database is located is not a problem of the appdomain: the ADO.NET provider has to solve that. I.o.w.: we can host the databases in an environment which offers itself as a single resource and is accessible through one connection string without replication overhead on the outside, and use that environment inside the .NET VM as if it was a single DB. But what about memory replication and other problems? This environment isn't simple, at least not for the cloud vendor. But it is simple for the customer who wants to run his sites in that cloud: no work needed. No refactoring needed of existing code. Upload it, run it. Perhaps I'm dreaming and what I described above isn't possible. Yet, I think if cloud vendors don't move into that direction, what they're offering isn't interesting: it doesn't solve a problem at all, it simply offers a way to instantiate more VMs with the guest OS of choice at the cost of me needing to refactor my website code so it can run in the straight jacket form factor dictated by the cloud vendor. Let's not kid ourselves here: most of us developers will never build a website which needs a truck load of VMs to run it: almost all websites created by developers can run on just a few VMs at most. Yet, the most expensive change is right at the start: moving from one to two VMs. As soon as you have refactored your website code to run across multiple VMs, adding another one is just as easy as clicking a mouse button. But that first step, that's the problem here and as it's right there at the beginning of scaling the website, it's particularly strange that cloud vendors refuse to solve that problem and leave it to the developers to solve that. Which makes migrating 'to the cloud' particularly expensive.

    Read the article

  • Best Practices - which domain types should be used to run applications

    - by jsavit
    This post is one of a series of "best practices" notes for Oracle VM Server for SPARC (formerly named Logical Domains) One question that frequently comes up is "which types of domain should I use to run applications?" There used to be a simple answer in most cases: "only run applications in guest domains", but enhancements to T-series servers, Oracle VM Server for SPARC and the advent of SPARC SuperCluster have made this question more interesting and worth qualifying differently. This article reviews the relevant concepts and provides suggestions on where to deploy applications in a logical domains environment. Review: division of labor and types of domain Oracle VM Server for SPARC offloads many functions from the hypervisor to domains (also called virtual machines). This is a modern alternative to using a "thick" hypervisor that provides all virtualization functions, as in traditional VM designs, This permits a simpler hypervisor design, which enhances reliability, and security. It also reduces single points of failure by assigning responsibilities to multiple system components, which further improves reliability and security. In this architecture, management and I/O functionality are provided within domains. Oracle VM Server for SPARC does this by defining the following types of domain, each with their own roles: Control domain - management control point for the server, used to configure domains and manage resources. It is the first domain to boot on a power-up, is an I/O domain, and is usually a service domain as well. I/O domain - has been assigned physical I/O devices: a PCIe root complex, a PCI device, or a SR-IOV (single-root I/O Virtualization) function. It has native performance and functionality for the devices it owns, unmediated by any virtualization layer. Service domain - provides virtual network and disk devices to guest domains. Guest domain - a domain whose devices are all virtual rather than physical: virtual network and disk devices provided by one or more service domains. In common practice, this is where applications are run. Typical deployment A service domain is generally also an I/O domain: otherwise it wouldn't have access to physical device "backends" to offer to its clients. Similarly, an I/O domain is also typically a service domain in order to leverage the available PCI busses. Control domains must be I/O domains, because they boot up first on the server and require physical I/O. It's typical for the control domain to also be a service domain too so it doesn't "waste" the I/O resources it uses. A simple configuration consists of a control domain, which is also the one I/O and service domain, and some number of guest domains using virtual I/O. In production, customers typically use multiple domains with I/O and service roles to eliminate single points of failure: guest domains have virtual disk and virtual devices provisioned from more than one service domain, so failure of a service domain or I/O path or device doesn't result in an application outage. This is also used for "rolling upgrades" in which service domains are upgraded one at a time while their guests continue to operate without disruption. (It should be noted that resiliency to I/O device failures can also be provided by the single control domain, using multi-path I/O) In this type of deployment, control, I/O, and service domains are used for virtualization infrastructure, while applications run in guest domains. Changing application deployment patterns The above model has been widely and successfully used, but more configuration options are available now. Servers got bigger than the original T2000 class machines with 2 I/O busses, so there is more I/O capacity that can be used for applications. Increased T-series server capacity made it attractive to run more vertical applications, such as databases, with higher resource requirements than the "light" applications originally seen. This made it attractive to run applications in I/O domains so they could get bare-metal native I/O performance. This is leveraged by the SPARC SuperCluster engineered system, announced a year ago at Oracle OpenWorld. In SPARC SuperCluster, I/O domains are used for high performance applications, with native I/O performance for disk and network and optimized access to the Infiniband fabric. Another technical enhancement is the introduction of Direct I/O (DIO) and Single Root I/O Virtualization (SR-IOV), which make it possible to give domains direct connections and native I/O performance for selected I/O devices. A domain with either a DIO or SR-IOV device is an I/O domain. In summary: not all I/O domains own PCI complexes, and there are increasingly more I/O domains that are not service domains. They use their I/O connectivity for performance for their own applications. However, there are some limitations and considerations: at this time, a domain using physical I/O cannot be live-migrated to another server. There is also a need to plan for security and introducing unneeded dependencies: if an I/O domain is also a service domain providing virtual I/O go guests, it has the ability to affect the correct operation of its client guest domains. This is even more relevant for the control domain. where the ldm has to be protected from unauthorized (or even mistaken) use that would affect other domains. As a general rule, running applications in the service domain or the control domain should be avoided. To recap: Guest domains with virtual I/O still provide the greatest operational flexibility, including features like live migration. I/O domains can be used for applications with high performance requirements. This is used to great effect in SPARC SuperCluster and in general T4 deployments. Direct I/O (DIO) and Single Root I/O Virtualization (SR-IOV) make this more attractive by giving direct I/O access to more domains. Service domains should in general not be used for applications, because compromised security in the domain, or an outage, can affect other domains that depend on it. This concern can be mitigated by providing guests' their virtual I/O from more than one service domain, so an interruption of service in the service domain does not cause an application outage. The control domain should in general not be used to run applications, for the same reason. SPARC SuperCluster use the control domain for applications, but it is an exception: it's not a general purpose environment; it's an engineered system with specifically configured applications and optimization for optimal performance. These are recommended "best practices" based on conversations with a number of Oracle architects. Keep in mind that "one size does not fit all", so you should evaluate these practices in the context of your own requirements. Summary Higher capacity T-series servers have made it more attractive to use them for applications with high resource requirements. New deployment models permit native I/O performance for demanding applications by running them in I/O domains with direct access to their devices. This is leveraged in SPARC SuperCluster, and can be leveraged in T-series servers to provision high-performance applications running in domains. Carefully planned, this can be used to provide higher performance for critical applications.

    Read the article

  • Wireless networks are not detected at start up in Ubuntu 12.04

    - by Kanhaiya Mishra
    I have recently (three four days ago) installed Ubuntu 12.04 via windows installer i.e. wubi.exe. After the installation completed wireless and Ethernet were both working well. But after restart wireless networks didn't show up while in the network manager both networking and wireless were enabled. Though sometimes after boot it did show the networks available but very rarely. So I went through various posts regarding wireless issues in Ubuntu 12.04 and tried so many things but ended up in nothing satisfactory. I have Broadcom 4313 LAN network controller and brcmsmac driver. Then relying on some suggestions I tried to install bcm-wl driver but couldn't install due to some error in jockeyl.log file. Then i tried fresh installation of the same driver but still could resolve the startup issues with wireless. Then again I reinstalled Ubuntu inside windows using wubi installer. This time again same problem occurred after boot. But this time I successfully installed wl driver before disturbing file-system files of Ubuntu. But again the same issue. This time I noticed some new things: If I inserted Ethernet/LAN cable before startup then wireless networks are available and of course LAN(wired) networks also work. but if i don't plug in cable before startup and then plug it after startup then it didn't detect Ethernet network neither wireless. So I haven't noticed it before that LAN along with wifi also doesn't work after startup. But if i suspend the session and make it sleep and again login then it worked. I tried it every time that WLAN worked perfectly. But still i m unable to resolve that startup problem. Each time i boot first I have to suspend it once then only networks are available. It irritates me each time i reboot/boot my lappy. So please help out of this problem. Any ideas/help regarding this issue would be highly appreciated. Some of the commands that i run gave following results: # lspci 00:00.0 Host bridge: Intel Corporation Core Processor DRAM Controller (rev 12) 00:02.0 VGA compatible controller: Intel Corporation Core Processor Integrated Graphics Controller (rev 12) 00:16.0 Communication controller: Intel Corporation 5 Series/3400 Series Chipset HECI Controller (rev 06) 00:1a.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1b.0 Audio device: Intel Corporation 5 Series/3400 Series Chipset High Definition Audio (rev 06) 00:1c.0 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 1 (rev 06) 00:1c.1 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 2 (rev 06) 00:1c.5 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 6 (rev 06) 00:1d.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev a6) 00:1f.0 ISA bridge: Intel Corporation Mobile 5 Series Chipset LPC Interface Controller (rev 06) 00:1f.2 SATA controller: Intel Corporation 5 Series/3400 Series Chipset 6 port SATA AHCI Controller (rev 06) 00:1f.3 SMBus: Intel Corporation 5 Series/3400 Series Chipset SMBus Controller (rev 06) 00:1f.6 Signal processing controller: Intel Corporation 5 Series/3400 Series Chipset Thermal Subsystem (rev 06) 03:00.0 Network controller: Broadcom Corporation BCM4313 802.11b/g/n Wireless LAN Controller (rev 01) 04:00.0 Ethernet controller: Atheros Communications Inc. AR8152 v1.1 Fast Ethernet (rev c1) ff:00.0 Host bridge: Intel Corporation Core Processor QuickPath Architecture Generic Non-core Registers (rev 02) ff:00.1 Host bridge: Intel Corporation Core Processor QuickPath Architecture System Address Decoder (rev 02) ff:02.0 Host bridge: Intel Corporation Core Processor QPI Link 0 (rev 02) ff:02.1 Host bridge: Intel Corporation Core Processor QPI Physical 0 (rev 02) ff:02.2 Host bridge: Intel Corporation Core Processor Reserved (rev 02) ff:02.3 Host bridge: Intel Corporation Core Processor Reserved (rev 02) # sudo lshw -C network *-network description: Wireless interface product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:03:00.0 logical name: eth1 version: 01 serial: 70:f1:a1:49:b6:ab width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=5.100.82.38 ip=192.168.1.7 latency=0 multicast=yes wireless=IEEE 802.11 resources: irq:17 memory:f0500000-f0503fff *-network description: Ethernet interface product: AR8152 v1.1 Fast Ethernet vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 logical name: eth0 version: c1 serial: b8:ac:6f:6b:f7:4a capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vpd bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=atl1c driverversion=1.0.1.0-NAPI firmware=N/A latency=0 link=no multicast=yes port=twisted pair resources: irq:44 memory:f0400000-f043ffff ioport:2000(size=128) # lsmod | grep wl wl 2568210 0 lib80211 14381 2 lib80211_crypt_tkip,wl # sudo iwlist eth1 scanning eth1 Scan completed : Cell 01 - Address: 30:46:9A:85:DA:9A ESSID:"BH DASHIR 2" Mode:Managed Frequency:2.462 GHz (Channel 11) Quality:4/5 Signal level:-60 dBm Noise level:-98 dBm IE: IEEE 802.11i/WPA2 Version 1 Group Cipher : CCMP Pairwise Ciphers (1) : CCMP Authentication Suites (1) : PSK IE: Unknown: DD7F0050F204104A00011010440001021041000100103B000103104700109AFE7D908F8E2D381860668BA2E8D8771021000D4E4554474541522C20496E632E10230009574752363134763130102400095747523631347631301042000538333235381054000800060050F204000110110009574752363134763130100800020084 Encryption key:on Bit Rates:1 Mb/s; 2 Mb/s; 5.5 Mb/s; 11 Mb/s; 18 Mb/s 24 Mb/s; 36 Mb/s; 54 Mb/s; 6 Mb/s; 9 Mb/s 12 Mb/s; 48 Mb/s Cell 02 - Address: C0:3F:0E:EB:45:14 ESSID:"BH DASHIR 3" Mode:Managed Frequency:2.462 GHz (Channel 11) Quality:2/5 Signal level:-71 dBm Noise level:-98 dBm IE: IEEE 802.11i/WPA2 Version 1 Group Cipher : CCMP Pairwise Ciphers (1) : CCMP Authentication Suites (1) : PSK IE: Unknown: DD7F0050F204104A00011010440001021041000100103B00010310470010F3C9BBE499D140540F530E7EBEDE2F671021000D4E4554474541522C20496E632E10230009574752363134763130102400095747523631347631301042000538333235381054000800060050F204000110110009574752363134763130100800020084 Encryption key:on Bit Rates:1 Mb/s; 2 Mb/s; 5.5 Mb/s; 11 Mb/s; 18 Mb/s 24 Mb/s; 36 Mb/s; 54 Mb/s; 6 Mb/s; 9 Mb/s 12 Mb/s; 48 Mb/s Cell 03 - Address: A0:21:B7:A8:2F:C0 ESSID:"BH DASHIR 4" Mode:Managed Frequency:2.422 GHz (Channel 3) Quality:1/5 Signal level:-86 dBm Noise level:-98 dBm IE: IEEE 802.11i/WPA2 Version 1 Group Cipher : CCMP Pairwise Ciphers (1) : CCMP Authentication Suites (1) : PSK IE: Unknown: DD8B0050F204104A0001101044000102103B0001031047001000000000000010000000A021B7A82FC01021000D4E6574676561722C20496E632E10230009574E523130303076321024000456324831104200046E6F6E651054000800060050F20400011011001B574E5231303030763228576972656C6573732041502D322E344729100800020086103C000103 Encryption key:on Bit Rates:1 Mb/s; 2 Mb/s; 5.5 Mb/s; 11 Mb/s; 6 Mb/s 9 Mb/s; 12 Mb/s; 18 Mb/s; 24 Mb/s; 36 Mb/s 48 Mb/s; 54 Mb/s

    Read the article

  • ?Oracle????SELECT????UNDO

    - by Liu Maclean(???)
    ????????Oracle?????(dirty read),?Oracle??????Asktom????????Oracle???????, ???undo??????????(before image)??????Consistent, ???????????????Oracle????????????? ????????? ??,??,Oracle?????????????RDBMS,???????????? ?????????2?????: _offline_rollback_segments or _corrupted_rollback_segments ?2?????????Oracle???????????ORA-600[4XXX]???????????????,???2??????Undo??Corruption????????????,?????2????????????????? ??????????????_offline_rollback_segments ? _corrupted_rollback_segments ?2?????: ???????(FORCE OPEN DATABASE) ????????????(consistent read & delayed block cleanout) ??????rollback segment??? ?????:???????Oracle????????,??????????2?????,?????????????!! _offline_rollback_segments ? _corrupted_rollback_segments ???????????: ??2???????Undo Segments(???/???)????????online ?UNDO$???????????OFFLINE??? ???instance??????????????????? ??????Undo Segments????????active transaction????????????dead??SMON???(????????SMON??(?):Recover Dead transaction) _OFFLINE_ROLLBACK_SEGMENTS(offline undo segment list)????(hidden parameter)?????: ???startup???open database???????_OFFLINE_ROLLBACK_SEGMENTS????Undo segments(???/???),?????undo segments????????alert.log???TRACE?????,???????startup?? ?????????????,?ITL?????undo segments?: ???undo segments?transaction table?????????????????? ???????????commit,?????CR??? ????undo segments????(???corrupted??,???missed??)???????????alert.log,??????? ?DML?????????????????????????????????CPU,????????????????????? _CORRUPTED_ROLLBACK_SEGMENTS(corrupted undo segment list)??????????: ?????startup?open database???_CORRUPTED_ROLLBACK_SEGMENTS????undo segments(???/???)???????? ???????_CORRUPTED_ROLLBACK_SEGMENTS???undo segments????????????commit,???undo segments???drop??? ??????????? ??????????????????,?????????????????? ??bootstrap???????????,?????????ORA-00704: bootstrap process failure??,???????????(???Oracle????:??ORA-00600:[4000] ORA-00704: bootstrap process failure????) ??????_CORRUPTED_ROLLBACK_SEGMENTS????????????????????,??????????????? Oracle???????TXChecker??????????? ???????2?????,??????????????_CORRUPTED_ROLLBACK_SEGMENTS?????SELECT????UNDO???????: SQL> alter system set event= '10513 trace name context forever, level 2' scope=spfile; System altered. SQL> alter system set "_in_memory_undo"=false scope=spfile; System altered. 10513 level 2 event????SMON ??rollback ??? dead transaction _in_memory_undo ?? in memory undo ?? SQL> startup force; ORACLE instance started. Total System Global Area 3140026368 bytes Fixed Size 2232472 bytes Variable Size 1795166056 bytes Database Buffers 1325400064 bytes Redo Buffers 17227776 bytes Database mounted. Database opened. session A: SQL> conn maclean/maclean Connected. SQL> create table maclean tablespace users as select 1 t1 from dual connect by level exec dbms_stats.gather_table_stats('','MACLEAN'); PL/SQL procedure successfully completed. SQL> set autotrace on; SQL> select sum(t1) from maclean; SUM(T1) ---------- 501 Execution Plan ---------------------------------------------------------- Plan hash value: 1679547536 ------------------------------------------------------------------------------ | Id | Operation | Name | Rows | Bytes | Cost (%CPU)| Time | ------------------------------------------------------------------------------ | 0 | SELECT STATEMENT | | 1 | 3 | 3 (0)| 00:00:01 | | 1 | SORT AGGREGATE | | 1 | 3 | | | | 2 | TABLE ACCESS FULL| MACLEAN | 501 | 1503 | 3 (0)| 00:00:01 | ------------------------------------------------------------------------------ Statistics ---------------------------------------------------------- 1 recursive calls 0 db block gets 3 consistent gets 0 physical reads 0 redo size 515 bytes sent via SQL*Net to client 492 bytes received via SQL*Net from client 2 SQL*Net roundtrips to/from client 0 sorts (memory) 0 sorts (disk) 1 rows processe ???????????,????current block, ????????,consistent gets??3? SQL> update maclean set t1=0; 501 rows updated. SQL> alter system checkpoint; System altered. ??session A?commit; ???? session: SQL> conn maclean/maclean Connected. SQL> SQL> set autotrace on; SQL> select sum(t1) from maclean; SUM(T1) ---------- 501 Execution Plan ---------------------------------------------------------- Plan hash value: 1679547536 ------------------------------------------------------------------------------ | Id | Operation | Name | Rows | Bytes | Cost (%CPU)| Time | ------------------------------------------------------------------------------ | 0 | SELECT STATEMENT | | 1 | 3 | 3 (0)| 00:00:01 | | 1 | SORT AGGREGATE | | 1 | 3 | | | | 2 | TABLE ACCESS FULL| MACLEAN | 501 | 1503 | 3 (0)| 00:00:01 | ------------------------------------------------------------------------------ Statistics ---------------------------------------------------------- 0 recursive calls 0 db block gets 505 consistent gets 0 physical reads 108 redo size 515 bytes sent via SQL*Net to client 492 bytes received via SQL*Net from client 2 SQL*Net roundtrips to/from client 0 sorts (memory) 0 sorts (disk) 1 rows processed ?????? ?????????undo??CR?,???consistent gets??? 505 [oracle@vrh8 ~]$ ps -ef|grep LOCAL=YES |grep -v grep oracle 5841 5839 0 09:17 ? 00:00:00 oracleG10R25 (DESCRIPTION=(LOCAL=YES)(ADDRESS=(PROTOCOL=beq))) [oracle@vrh8 ~]$ kill -9 5841 ??session A???Server Process????,???dead transaction ????smon?? select ktuxeusn, to_char(sysdate, 'DD-MON-YYYY HH24:MI:SS') "Time", ktuxesiz, ktuxesta from x$ktuxe where ktuxecfl = 'DEAD'; KTUXEUSN Time KTUXESIZ KTUXESTA ---------- -------------------- ---------- ---------------- 2 06-AUG-2012 09:20:45 7 ACTIVE ???1?active rollback segment SQL> conn maclean/maclean Connected. SQL> set autotrace on; SQL> select sum(t1) from maclean; SUM(T1) ---------- 501 Execution Plan ---------------------------------------------------------- Plan hash value: 1679547536 ------------------------------------------------------------------------------ | Id | Operation | Name | Rows | Bytes | Cost (%CPU)| Time | ------------------------------------------------------------------------------ | 0 | SELECT STATEMENT | | 1 | 3 | 3 (0)| 00:00:01 | | 1 | SORT AGGREGATE | | 1 | 3 | | | | 2 | TABLE ACCESS FULL| MACLEAN | 501 | 1503 | 3 (0)| 00:00:01 | ------------------------------------------------------------------------------ Statistics ---------------------------------------------------------- 0 recursive calls 0 db block gets 411 consistent gets 0 physical reads 108 redo size 515 bytes sent via SQL*Net to client 492 bytes received via SQL*Net from client 2 SQL*Net roundtrips to/from client 0 sorts (memory) 0 sorts (disk) 1 rows processed ????? ????kill?? ???smon ??dead transaction , ???????????? ?????undo??????? ????active?rollback segment??? SQL> select segment_name from dba_rollback_segs where segment_id=2; SEGMENT_NAME ------------------------------ _SYSSMU2$ SQL> alter system set "_corrupted_rollback_segments"='_SYSSMU2$' scope=spfile; System altered. ? _corrupted_rollback_segments ?? ???2?rollback segment, ????????undo SQL> startup force; ORACLE instance started. Total System Global Area 3140026368 bytes Fixed Size 2232472 bytes Variable Size 1795166056 bytes Database Buffers 1325400064 bytes Redo Buffers 17227776 bytes Database mounted. Database opened. SQL> conn maclean/maclean Connected. SQL> set autotrace on; SQL> select sum(t1) from maclean; SUM(T1) ---------- 94 Execution Plan ---------------------------------------------------------- Plan hash value: 1679547536 ------------------------------------------------------------------------------ | Id | Operation | Name | Rows | Bytes | Cost (%CPU)| Time | ------------------------------------------------------------------------------ | 0 | SELECT STATEMENT | | 1 | 3 | 3 (0)| 00:00:01 | | 1 | SORT AGGREGATE | | 1 | 3 | | | | 2 | TABLE ACCESS FULL| MACLEAN | 501 | 1503 | 3 (0)| 00:00:01 | ------------------------------------------------------------------------------ Statistics ---------------------------------------------------------- 228 recursive calls 0 db block gets 29 consistent gets 5 physical reads 116 redo size 514 bytes sent via SQL*Net to client 492 bytes received via SQL*Net from client 2 SQL*Net roundtrips to/from client 4 sorts (memory) 0 sorts (disk) 1 rows processed SQL> / SUM(T1) ---------- 94 Execution Plan ---------------------------------------------------------- Plan hash value: 1679547536 ------------------------------------------------------------------------------ | Id | Operation | Name | Rows | Bytes | Cost (%CPU)| Time | ------------------------------------------------------------------------------ | 0 | SELECT STATEMENT | | 1 | 3 | 3 (0)| 00:00:01 | | 1 | SORT AGGREGATE | | 1 | 3 | | | | 2 | TABLE ACCESS FULL| MACLEAN | 501 | 1503 | 3 (0)| 00:00:01 | ------------------------------------------------------------------------------ Statistics ---------------------------------------------------------- 0 recursive calls 0 db block gets 3 consistent gets 0 physical reads 0 redo size 514 bytes sent via SQL*Net to client 492 bytes received via SQL*Net from client 2 SQL*Net roundtrips to/from client 0 sorts (memory) 0 sorts (disk) 1 rows processed ?????? consistent gets???3,?????????????????,??ITL???UNDO SEGMENTS?_corrupted_rollback_segments????,???????????COMMIT??,????UNDO? ???????,?????????????????????????(????????????????????),????????????????? ???? , ?????

    Read the article

  • Beware Sneaky Reads with Unique Indexes

    - by Paul White NZ
    A few days ago, Sandra Mueller (twitter | blog) asked a question using twitter’s #sqlhelp hash tag: “Might SQL Server retrieve (out-of-row) LOB data from a table, even if the column isn’t referenced in the query?” Leaving aside trivial cases (like selecting a computed column that does reference the LOB data), one might be tempted to say that no, SQL Server does not read data you haven’t asked for.  In general, that’s quite correct; however there are cases where SQL Server might sneakily retrieve a LOB column… Example Table Here’s a T-SQL script to create that table and populate it with 1,000 rows: CREATE TABLE dbo.LOBtest ( pk INTEGER IDENTITY NOT NULL, some_value INTEGER NULL, lob_data VARCHAR(MAX) NULL, another_column CHAR(5) NULL, CONSTRAINT [PK dbo.LOBtest pk] PRIMARY KEY CLUSTERED (pk ASC) ); GO DECLARE @Data VARCHAR(MAX); SET @Data = REPLICATE(CONVERT(VARCHAR(MAX), 'x'), 65540);   WITH Numbers (n) AS ( SELECT ROW_NUMBER() OVER (ORDER BY (SELECT 0)) FROM master.sys.columns C1, master.sys.columns C2 ) INSERT LOBtest WITH (TABLOCKX) ( some_value, lob_data ) SELECT TOP (1000) N.n, @Data FROM Numbers N WHERE N.n <= 1000; Test 1: A Simple Update Let’s run a query to subtract one from every value in the some_value column: UPDATE dbo.LOBtest WITH (TABLOCKX) SET some_value = some_value - 1; As you might expect, modifying this integer column in 1,000 rows doesn’t take very long, or use many resources.  The STATITICS IO and TIME output shows a total of 9 logical reads, and 25ms elapsed time.  The query plan is also very simple: Looking at the Clustered Index Scan, we can see that SQL Server only retrieves the pk and some_value columns during the scan: The pk column is needed by the Clustered Index Update operator to uniquely identify the row that is being changed.  The some_value column is used by the Compute Scalar to calculate the new value.  (In case you are wondering what the Top operator is for, it is used to enforce SET ROWCOUNT). Test 2: Simple Update with an Index Now let’s create a nonclustered index keyed on the some_value column, with lob_data as an included column: CREATE NONCLUSTERED INDEX [IX dbo.LOBtest some_value (lob_data)] ON dbo.LOBtest (some_value) INCLUDE ( lob_data ) WITH ( FILLFACTOR = 100, MAXDOP = 1, SORT_IN_TEMPDB = ON ); This is not a useful index for our simple update query; imagine that someone else created it for a different purpose.  Let’s run our update query again: UPDATE dbo.LOBtest WITH (TABLOCKX) SET some_value = some_value - 1; We find that it now requires 4,014 logical reads and the elapsed query time has increased to around 100ms.  The extra logical reads (4 per row) are an expected consequence of maintaining the nonclustered index. The query plan is very similar to before (click to enlarge): The Clustered Index Update operator picks up the extra work of maintaining the nonclustered index. The new Compute Scalar operators detect whether the value in the some_value column has actually been changed by the update.  SQL Server may be able to skip maintaining the nonclustered index if the value hasn’t changed (see my previous post on non-updating updates for details).  Our simple query does change the value of some_data in every row, so this optimization doesn’t add any value in this specific case. The output list of columns from the Clustered Index Scan hasn’t changed from the one shown previously: SQL Server still just reads the pk and some_data columns.  Cool. Overall then, adding the nonclustered index hasn’t had any startling effects, and the LOB column data still isn’t being read from the table.  Let’s see what happens if we make the nonclustered index unique. Test 3: Simple Update with a Unique Index Here’s the script to create a new unique index, and drop the old one: CREATE UNIQUE NONCLUSTERED INDEX [UQ dbo.LOBtest some_value (lob_data)] ON dbo.LOBtest (some_value) INCLUDE ( lob_data ) WITH ( FILLFACTOR = 100, MAXDOP = 1, SORT_IN_TEMPDB = ON ); GO DROP INDEX [IX dbo.LOBtest some_value (lob_data)] ON dbo.LOBtest; Remember that SQL Server only enforces uniqueness on index keys (the some_data column).  The lob_data column is simply stored at the leaf-level of the non-clustered index.  With that in mind, we might expect this change to make very little difference.  Let’s see: UPDATE dbo.LOBtest WITH (TABLOCKX) SET some_value = some_value - 1; Whoa!  Now look at the elapsed time and logical reads: Scan count 1, logical reads 2016, physical reads 0, read-ahead reads 0, lob logical reads 36015, lob physical reads 0, lob read-ahead reads 15992.   CPU time = 172 ms, elapsed time = 16172 ms. Even with all the data and index pages in memory, the query took over 16 seconds to update just 1,000 rows, performing over 52,000 LOB logical reads (nearly 16,000 of those using read-ahead). Why on earth is SQL Server reading LOB data in a query that only updates a single integer column? The Query Plan The query plan for test 3 looks a bit more complex than before: In fact, the bottom level is exactly the same as we saw with the non-unique index.  The top level has heaps of new stuff though, which I’ll come to in a moment. You might be expecting to find that the Clustered Index Scan is now reading the lob_data column (for some reason).  After all, we need to explain where all the LOB logical reads are coming from.  Sadly, when we look at the properties of the Clustered Index Scan, we see exactly the same as before: SQL Server is still only reading the pk and some_value columns – so what’s doing the LOB reads? Updates that Sneakily Read Data We have to go as far as the Clustered Index Update operator before we see LOB data in the output list: [Expr1020] is a bit flag added by an earlier Compute Scalar.  It is set true if the some_value column has not been changed (part of the non-updating updates optimization I mentioned earlier). The Clustered Index Update operator adds two new columns: the lob_data column, and some_value_OLD.  The some_value_OLD column, as the name suggests, is the pre-update value of the some_value column.  At this point, the clustered index has already been updated with the new value, but we haven’t touched the nonclustered index yet. An interesting observation here is that the Clustered Index Update operator can read a column into the data flow as part of its update operation.  SQL Server could have read the LOB data as part of the initial Clustered Index Scan, but that would mean carrying the data through all the operations that occur prior to the Clustered Index Update.  The server knows it will have to go back to the clustered index row to update it, so it delays reading the LOB data until then.  Sneaky! Why the LOB Data Is Needed This is all very interesting (I hope), but why is SQL Server reading the LOB data?  For that matter, why does it need to pass the pre-update value of the some_value column out of the Clustered Index Update? The answer relates to the top row of the query plan for test 3.  I’ll reproduce it here for convenience: Notice that this is a wide (per-index) update plan.  SQL Server used a narrow (per-row) update plan in test 2, where the Clustered Index Update took care of maintaining the nonclustered index too.  I’ll talk more about this difference shortly. The Split/Sort/Collapse combination is an optimization, which aims to make per-index update plans more efficient.  It does this by breaking each update into a delete/insert pair, reordering the operations, removing any redundant operations, and finally applying the net effect of all the changes to the nonclustered index. Imagine we had a unique index which currently holds three rows with the values 1, 2, and 3.  If we run a query that adds 1 to each row value, we would end up with values 2, 3, and 4.  The net effect of all the changes is the same as if we simply deleted the value 1, and added a new value 4. By applying net changes, SQL Server can also avoid false unique-key violations.  If we tried to immediately update the value 1 to a 2, it would conflict with the existing value 2 (which would soon be updated to 3 of course) and the query would fail.  You might argue that SQL Server could avoid the uniqueness violation by starting with the highest value (3) and working down.  That’s fine, but it’s not possible to generalize this logic to work with every possible update query. SQL Server has to use a wide update plan if it sees any risk of false uniqueness violations.  It’s worth noting that the logic SQL Server uses to detect whether these violations are possible has definite limits.  As a result, you will often receive a wide update plan, even when you can see that no violations are possible. Another benefit of this optimization is that it includes a sort on the index key as part of its work.  Processing the index changes in index key order promotes sequential I/O against the nonclustered index. A side-effect of all this is that the net changes might include one or more inserts.  In order to insert a new row in the index, SQL Server obviously needs all the columns – the key column and the included LOB column.  This is the reason SQL Server reads the LOB data as part of the Clustered Index Update. In addition, the some_value_OLD column is required by the Split operator (it turns updates into delete/insert pairs).  In order to generate the correct index key delete operation, it needs the old key value. The irony is that in this case the Split/Sort/Collapse optimization is anything but.  Reading all that LOB data is extremely expensive, so it is sad that the current version of SQL Server has no way to avoid it. Finally, for completeness, I should mention that the Filter operator is there to filter out the non-updating updates. Beating the Set-Based Update with a Cursor One situation where SQL Server can see that false unique-key violations aren’t possible is where it can guarantee that only one row is being updated.  Armed with this knowledge, we can write a cursor (or the WHILE-loop equivalent) that updates one row at a time, and so avoids reading the LOB data: SET NOCOUNT ON; SET STATISTICS XML, IO, TIME OFF;   DECLARE @PK INTEGER, @StartTime DATETIME; SET @StartTime = GETUTCDATE();   DECLARE curUpdate CURSOR LOCAL FORWARD_ONLY KEYSET SCROLL_LOCKS FOR SELECT L.pk FROM LOBtest L ORDER BY L.pk ASC;   OPEN curUpdate;   WHILE (1 = 1) BEGIN FETCH NEXT FROM curUpdate INTO @PK;   IF @@FETCH_STATUS = -1 BREAK; IF @@FETCH_STATUS = -2 CONTINUE;   UPDATE dbo.LOBtest SET some_value = some_value - 1 WHERE CURRENT OF curUpdate; END;   CLOSE curUpdate; DEALLOCATE curUpdate;   SELECT DATEDIFF(MILLISECOND, @StartTime, GETUTCDATE()); That completes the update in 1280 milliseconds (remember test 3 took over 16 seconds!) I used the WHERE CURRENT OF syntax there and a KEYSET cursor, just for the fun of it.  One could just as well use a WHERE clause that specified the primary key value instead. Clustered Indexes A clustered index is the ultimate index with included columns: all non-key columns are included columns in a clustered index.  Let’s re-create the test table and data with an updatable primary key, and without any non-clustered indexes: IF OBJECT_ID(N'dbo.LOBtest', N'U') IS NOT NULL DROP TABLE dbo.LOBtest; GO CREATE TABLE dbo.LOBtest ( pk INTEGER NOT NULL, some_value INTEGER NULL, lob_data VARCHAR(MAX) NULL, another_column CHAR(5) NULL, CONSTRAINT [PK dbo.LOBtest pk] PRIMARY KEY CLUSTERED (pk ASC) ); GO DECLARE @Data VARCHAR(MAX); SET @Data = REPLICATE(CONVERT(VARCHAR(MAX), 'x'), 65540);   WITH Numbers (n) AS ( SELECT ROW_NUMBER() OVER (ORDER BY (SELECT 0)) FROM master.sys.columns C1, master.sys.columns C2 ) INSERT LOBtest WITH (TABLOCKX) ( pk, some_value, lob_data ) SELECT TOP (1000) N.n, N.n, @Data FROM Numbers N WHERE N.n <= 1000; Now here’s a query to modify the cluster keys: UPDATE dbo.LOBtest SET pk = pk + 1; The query plan is: As you can see, the Split/Sort/Collapse optimization is present, and we also gain an Eager Table Spool, for Halloween protection.  In addition, SQL Server now has no choice but to read the LOB data in the Clustered Index Scan: The performance is not great, as you might expect (even though there is no non-clustered index to maintain): Table 'LOBtest'. Scan count 1, logical reads 2011, physical reads 0, read-ahead reads 0, lob logical reads 36015, lob physical reads 0, lob read-ahead reads 15992.   Table 'Worktable'. Scan count 1, logical reads 2040, physical reads 0, read-ahead reads 0, lob logical reads 34000, lob physical reads 0, lob read-ahead reads 8000.   SQL Server Execution Times: CPU time = 483 ms, elapsed time = 17884 ms. Notice how the LOB data is read twice: once from the Clustered Index Scan, and again from the work table in tempdb used by the Eager Spool. If you try the same test with a non-unique clustered index (rather than a primary key), you’ll get a much more efficient plan that just passes the cluster key (including uniqueifier) around (no LOB data or other non-key columns): A unique non-clustered index (on a heap) works well too: Both those queries complete in a few tens of milliseconds, with no LOB reads, and just a few thousand logical reads.  (In fact the heap is rather more efficient). There are lots more fun combinations to try that I don’t have space for here. Final Thoughts The behaviour shown in this post is not limited to LOB data by any means.  If the conditions are met, any unique index that has included columns can produce similar behaviour – something to bear in mind when adding large INCLUDE columns to achieve covering queries, perhaps. Paul White Email: [email protected] Twitter: @PaulWhiteNZ

    Read the article

  • Grub 'Read Error' - Only Loads with LiveCD

    - by Ryan Sharp
    Problem After installing Ubuntu to complete my Windows 7/Ubuntu 12.04 dual-boot setup, Grub just wouldn't load at all unless I boot from the LiveCD. Afterwards, everything works completely normal. However, this workaround isn't a solution and I'd like to be able to boot without the aid of a disc. Fdisk -l Using the fdisk -l command, I am given the following: Disk /dev/sda: 64.0 GB, 64023257088 bytes 255 heads, 63 sectors/track, 7783 cylinders, total 125045424 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x324971d1 Device Boot Start End Blocks Id System /dev/sda1 2048 206847 102400 7 HPFS/NTFS/exFAT /dev/sda2 208896 48957439 24374272 7 HPFS/NTFS/exFAT /dev/sda3 * 48959486 124067839 37554177 5 Extended /dev/sda5 48959488 124067839 37554176 83 Linux Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xc0ee6a69 Device Boot Start End Blocks Id System /dev/sdb1 1024208894 1953523711 464657409 5 Extended /dev/sdb3 * 2048 1024206847 512102400 7 HPFS/NTFS/exFAT /dev/sdb5 1024208896 1937897471 456844288 83 Linux /dev/sdb6 1937899520 1953523711 7812096 82 Linux swap / Solaris Partition table entries are not in disk order Disk /dev/sdc: 320.1 GB, 320072933376 bytes 255 heads, 63 sectors/track, 38913 cylinders, total 625142448 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x292eee23 Device Boot Start End Blocks Id System /dev/sdc1 2048 625141759 312569856 7 HPFS/NTFS/exFAT Bootinfoscript I've used the BootInfoScript, and received the following output: Boot Info Script 0.61 [1 April 2012] ============================= Boot Info Summary: =============================== => Grub2 (v1.99) is installed in the MBR of /dev/sda and looks at sector 1 of the same hard drive for core.img. core.img is at this location and looks for (,msdos5)/boot/grub on this drive. => Grub2 (v1.99) is installed in the MBR of /dev/sdb and looks at sector 1 of the same hard drive for core.img. core.img is at this location and looks for (,msdos5)/boot/grub on this drive. => Windows is installed in the MBR of /dev/sdc. sda1: __________________________________________________________________________ File system: ntfs Boot sector type: Windows Vista/7: NTFS Boot sector info: No errors found in the Boot Parameter Block. Operating System: Boot files: /bootmgr /Boot/BCD sda2: __________________________________________________________________________ File system: ntfs Boot sector type: Windows Vista/7: NTFS Boot sector info: No errors found in the Boot Parameter Block. Operating System: Windows 7 Boot files: /bootmgr /Boot/BCD /Windows/System32/winload.exe sda3: __________________________________________________________________________ File system: Extended Partition Boot sector type: Unknown Boot sector info: sda5: __________________________________________________________________________ File system: ext4 Boot sector type: - Boot sector info: Operating System: Ubuntu 12.04.1 LTS Boot files: /boot/grub/grub.cfg /etc/fstab /boot/grub/core.img sdb1: __________________________________________________________________________ File system: Extended Partition Boot sector type: - Boot sector info: sdb5: __________________________________________________________________________ File system: ext4 Boot sector type: - Boot sector info: Operating System: Boot files: sdb6: __________________________________________________________________________ File system: swap Boot sector type: - Boot sector info: sdb3: __________________________________________________________________________ File system: ntfs Boot sector type: Windows Vista/7: NTFS Boot sector info: According to the info in the boot sector, sdb3 starts at sector 200744960. But according to the info from fdisk, sdb3 starts at sector 2048. According to the info in the boot sector, sdb3 has 823461887 sectors, but according to the info from fdisk, it has 1024204799 sectors. Operating System: Boot files: sdc1: __________________________________________________________________________ File system: ntfs Boot sector type: Windows Vista/7: NTFS Boot sector info: No errors found in the Boot Parameter Block. Operating System: Boot files: ============================ Drive/Partition Info: ============================= Drive: sda _____________________________________________________________________ Disk /dev/sda: 64.0 GB, 64023257088 bytes 255 heads, 63 sectors/track, 7783 cylinders, total 125045424 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes Partition Boot Start Sector End Sector # of Sectors Id System /dev/sda1 2,048 206,847 204,800 7 NTFS / exFAT / HPFS /dev/sda2 208,896 48,957,439 48,748,544 7 NTFS / exFAT / HPFS /dev/sda3 * 48,959,486 124,067,839 75,108,354 5 Extended /dev/sda5 48,959,488 124,067,839 75,108,352 83 Linux Drive: sdb _____________________________________________________________________ Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes Partition Boot Start Sector End Sector # of Sectors Id System /dev/sdb1 1,024,208,894 1,953,523,711 929,314,818 5 Extended /dev/sdb5 1,024,208,896 1,937,897,471 913,688,576 83 Linux /dev/sdb6 1,937,899,520 1,953,523,711 15,624,192 82 Linux swap / Solaris /dev/sdb3 * 2,048 1,024,206,847 1,024,204,800 7 NTFS / exFAT / HPFS Drive: sdc _____________________________________________________________________ Disk /dev/sdc: 320.1 GB, 320072933376 bytes 255 heads, 63 sectors/track, 38913 cylinders, total 625142448 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes Partition Boot Start Sector End Sector # of Sectors Id System /dev/sdc1 2,048 625,141,759 625,139,712 7 NTFS / exFAT / HPFS "blkid" output: ________________________________________________________________ Device UUID TYPE LABEL /dev/sda1 A48056DF8056B80E ntfs System Reserved /dev/sda2 A8C6D6A4C6D671D4 ntfs Windows /dev/sda5 fd71c537-3715-44e1-b1fe-07537e22b3dd ext4 /dev/sdb3 6373D03D0A3747A8 ntfs Steam /dev/sdb5 6f5a6eb3-a932-45aa-893e-045b57708270 ext4 /dev/sdb6 469848c8-867a-41b7-b0e1-b813a43c64af swap /dev/sdc1 725D7B961CF34B1B ntfs backup ================================ Mount points: ================================= Device Mount_Point Type Options /dev/sda5 / ext4 (rw,noatime,nodiratime,discard,errors=remount-ro) /dev/sdb5 /home ext4 (rw) =========================== sda5/boot/grub/grub.cfg: =========================== -------------------------------------------------------------------------------- # # DO NOT EDIT THIS FILE # # It is automatically generated by grub-mkconfig using templates # from /etc/grub.d and settings from /etc/default/grub # ### BEGIN /etc/grub.d/00_header ### if [ -s $prefix/grubenv ]; then set have_grubenv=true load_env fi set default="0" if [ "${prev_saved_entry}" ]; then set saved_entry="${prev_saved_entry}" save_env saved_entry set prev_saved_entry= save_env prev_saved_entry set boot_once=true fi function savedefault { if [ -z "${boot_once}" ]; then saved_entry="${chosen}" save_env saved_entry fi } function recordfail { set recordfail=1 if [ -n "${have_grubenv}" ]; then if [ -z "${boot_once}" ]; then save_env recordfail; fi; fi } function load_video { insmod vbe insmod vga insmod video_bochs insmod video_cirrus } insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set=root fd71c537-3715-44e1-b1fe-07537e22b3dd if loadfont /usr/share/grub/unicode.pf2 ; then set gfxmode=auto load_video insmod gfxterm insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set=root fd71c537-3715-44e1-b1fe-07537e22b3dd set locale_dir=($root)/boot/grub/locale set lang=en_GB insmod gettext fi terminal_output gfxterm if [ "${recordfail}" = 1 ]; then set timeout=-1 else set timeout=10 fi ### END /etc/grub.d/00_header ### ### BEGIN /etc/grub.d/05_debian_theme ### set menu_color_normal=white/black set menu_color_highlight=black/light-gray if background_color 44,0,30; then clear fi ### END /etc/grub.d/05_debian_theme ### ### BEGIN /etc/grub.d/10_linux ### function gfxmode { set gfxpayload="${1}" if [ "${1}" = "keep" ]; then set vt_handoff=vt.handoff=7 else set vt_handoff= fi } if [ "${recordfail}" != 1 ]; then if [ -e ${prefix}/gfxblacklist.txt ]; then if hwmatch ${prefix}/gfxblacklist.txt 3; then if [ ${match} = 0 ]; then set linux_gfx_mode=keep else set linux_gfx_mode=text fi else set linux_gfx_mode=text fi else set linux_gfx_mode=keep fi else set linux_gfx_mode=text fi export linux_gfx_mode if [ "${linux_gfx_mode}" != "text" ]; then load_video; fi menuentry 'Ubuntu, with Linux 3.2.0-29-generic' --class ubuntu --class gnu-linux --class gnu --class os { recordfail gfxmode $linux_gfx_mode insmod gzio insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set=root fd71c537-3715-44e1-b1fe-07537e22b3dd linux /boot/vmlinuz-3.2.0-29-generic root=UUID=fd71c537-3715-44e1-b1fe-07537e22b3dd ro quiet splash $vt_handoff initrd /boot/initrd.img-3.2.0-29-generic } menuentry 'Ubuntu, with Linux 3.2.0-29-generic (recovery mode)' --class ubuntu --class gnu-linux --class gnu --class os { recordfail insmod gzio insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set=root fd71c537-3715-44e1-b1fe-07537e22b3dd echo 'Loading Linux 3.2.0-29-generic ...' linux /boot/vmlinuz-3.2.0-29-generic root=UUID=fd71c537-3715-44e1-b1fe-07537e22b3dd ro recovery nomodeset echo 'Loading initial ramdisk ...' initrd /boot/initrd.img-3.2.0-29-generic } ### END /etc/grub.d/10_linux ### ### BEGIN /etc/grub.d/20_linux_xen ### ### END /etc/grub.d/20_linux_xen ### ### BEGIN /etc/grub.d/20_memtest86+ ### menuentry "Memory test (memtest86+)" { insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set=root fd71c537-3715-44e1-b1fe-07537e22b3dd linux16 /boot/memtest86+.bin } menuentry "Memory test (memtest86+, serial console 115200)" { insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set=root fd71c537-3715-44e1-b1fe-07537e22b3dd linux16 /boot/memtest86+.bin console=ttyS0,115200n8 } ### END /etc/grub.d/20_memtest86+ ### ### BEGIN /etc/grub.d/30_os-prober ### menuentry "Windows 7 (loader) (on /dev/sda1)" --class windows --class os { insmod part_msdos insmod ntfs set root='(hd0,msdos1)' search --no-floppy --fs-uuid --set=root A48056DF8056B80E chainloader +1 } menuentry "Windows 7 (loader) (on /dev/sda2)" --class windows --class os { insmod part_msdos insmod ntfs set root='(hd0,msdos2)' search --no-floppy --fs-uuid --set=root A8C6D6A4C6D671D4 chainloader +1 } ### END /etc/grub.d/30_os-prober ### ### BEGIN /etc/grub.d/40_custom ### # This file provides an easy way to add custom menu entries. Simply type the # menu entries you want to add after this comment. Be careful not to change # the 'exec tail' line above. ### END /etc/grub.d/40_custom ### ### BEGIN /etc/grub.d/41_custom ### if [ -f $prefix/custom.cfg ]; then source $prefix/custom.cfg; fi ### END /etc/grub.d/41_custom ### -------------------------------------------------------------------------------- =============================== sda5/etc/fstab: ================================ -------------------------------------------------------------------------------- # /etc/fstab: static file system information. # # Use 'blkid' to print the universally unique identifier for a # device; this may be used with UUID= as a more robust way to name devices # that works even if disks are added and removed. See fstab(5). # # <file system> <mount point> <type> <options> <dump> <pass> proc /proc proc nodev,noexec,nosuid 0 0 # / was on /dev/sda5 during installation UUID=fd71c537-3715-44e1-b1fe-07537e22b3dd / ext4 noatime,nodiratime,discard,errors=remount-ro 0 1 # /home was on /dev/sdb5 during installation UUID=6f5a6eb3-a932-45aa-893e-045b57708270 /home ext4 defaults 0 2 # swap was on /dev/sdb6 during installation UUID=469848c8-867a-41b7-b0e1-b813a43c64af none swap sw 0 0 tmpfs /tmp tmpfs defaults,noatime,mode=1777 0 0 -------------------------------------------------------------------------------- =================== sda5: Location of files loaded by Grub: ==================== GiB - GB File Fragment(s) = boot/grub/core.img 1 = boot/grub/grub.cfg 1 = boot/initrd.img-3.2.0-29-generic 2 = boot/vmlinuz-3.2.0-29-generic 1 = initrd.img 2 = vmlinuz 1 ======================== Unknown MBRs/Boot Sectors/etc: ======================== Unknown BootLoader on sda3 00000000 63 6f 70 69 61 20 65 20 63 6f 6c 61 41 63 65 64 |copia e colaAced| 00000010 65 72 20 61 20 74 6f 64 6f 20 6f 20 74 65 78 74 |er a todo o text| 00000020 6f 20 66 61 6c 61 64 6f 20 75 74 69 6c 69 7a 61 |o falado utiliza| 00000030 6e 64 6f 20 61 20 63 6f 6e 76 65 72 73 c3 a3 6f |ndo a convers..o| 00000040 20 64 65 20 74 65 78 74 6f 20 70 61 72 61 20 76 | de texto para v| 00000050 6f 7a 4d 61 6e 69 70 75 6c 61 72 20 61 73 20 64 |ozManipular as d| 00000060 65 66 69 6e 69 c3 a7 c3 b5 65 73 20 71 75 65 20 |efini....es que | 00000070 63 6f 6e 74 72 6f 6c 61 6d 20 6f 20 61 63 65 73 |controlam o aces| 00000080 73 6f 20 64 65 20 57 65 62 73 69 74 65 73 20 61 |so de Websites a| 00000090 20 63 6f 6f 6b 69 65 73 2c 20 4a 61 76 61 53 63 | cookies, JavaSc| 000000a0 72 69 70 74 20 65 20 70 6c 75 67 2d 69 6e 73 4d |ript e plug-insM| 000000b0 61 6e 69 70 75 6c 61 72 20 61 73 20 64 65 66 69 |anipular as defi| 000000c0 6e 69 c3 a7 c3 b5 65 73 20 72 65 6c 61 63 69 6f |ni....es relacio| 000000d0 6e 61 64 61 73 20 63 6f 6d 20 70 72 69 76 61 63 |nadas com privac| 000000e0 69 64 61 64 65 41 63 65 64 65 72 20 61 6f 73 20 |idadeAceder aos | 000000f0 73 65 75 73 20 70 65 72 69 66 c3 a9 72 69 63 6f |seus perif..rico| 00000100 73 20 55 53 42 55 74 69 6c 69 7a 61 72 20 6f 20 |s USBUtilizar o | 00000110 73 65 75 20 6d 69 63 72 6f 66 6f 6e 65 55 74 69 |seu microfoneUti| 00000120 6c 69 7a 61 72 20 61 20 73 75 61 20 63 c3 a2 6d |lizar a sua c..m| 00000130 61 72 61 55 74 69 6c 69 7a 61 72 20 6f 20 73 65 |araUtilizar o se| 00000140 75 20 6d 69 63 72 6f 66 6f 6e 65 20 65 20 61 20 |u microfone e a | 00000150 63 c3 a2 6d 61 72 61 4e c3 a3 6f 20 66 6f 69 20 |c..maraN..o foi | 00000160 70 6f 73 73 c3 ad 76 65 6c 20 65 6e 63 6f 6e 74 |poss..vel encont| 00000170 72 61 72 20 6f 20 63 61 6d 69 6e 68 6f 20 61 62 |rar o caminho ab| 00000180 73 6f 6c 75 74 6f 20 70 61 72 61 20 6f 20 64 69 |soluto para o di| 00000190 72 65 63 74 c3 b3 72 69 6f 20 61 20 65 6d 70 61 |rect..rio a empa| 000001a0 63 6f 74 61 72 2e 4f 20 64 69 72 65 63 74 c3 b3 |cotar.O direct..| 000001b0 72 69 6f 20 64 65 20 65 6e 74 72 61 64 61 00 fe |rio de entrada..| 000001c0 ff ff 83 fe ff ff 02 00 00 00 00 10 7a 04 00 00 |............z...| 000001d0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| * 000001f0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 55 aa |..............U.| 00000200 =============================== StdErr Messages: =============================== xz: (stdin): Compressed data is corrupt xz: (stdin): Compressed data is corrupt awk: cmd. line:36: Math support is not compiled in awk: cmd. line:36: Math support is not compiled in awk: cmd. line:36: Math support is not compiled in awk: cmd. line:36: Math support is not compiled in awk: cmd. line:36: Math support is not compiled in awk: cmd. line:36: Math support is not compiled in Begging / Appreciation ;) If anything else is required to solve my problem, please ask. My only hopes are that I can solve this, and that doing so won't require re-installation of Grub due to how complicated the procedures are, or that I would be needed to reinstall the OS', as I have done so about six times already since friday due to several other issues I've encountered. Thank you, and good day. System Ubuntu 12.04 64-bit / Windows 7 SP1 64-bit 64GB SSD as boot/OS drive, 1TB HDD as /Home Swap and Steam drive.

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?