Search Results

Search found 27973 results on 1119 pages for 'power point vba'.

Page 24/1119 | < Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >

  • Check for duplicate rows in 2 columns before update

    - by user3891378
    I have a table with 4 columns, and I need to check to see if a Column Pair exists before inserting a row into the database: INSERT INTO dbo.tblCallReport_Detail (fkCallReport, fkProductCategory, Discussion, Action) VALUES (?, ?, ?, ?) The pair in question is fkCallReport and fkProductCategory. For example if the row trying to be inserted has fkCallReport = 3 and fkProductCategory = 5, and the database already has both of those values together, it should display an error and ask if they would like to combine the Disuccsion and Action with the current record. Keep in mind I'm doing this in VBA Access 2010 and am still very new.

    Read the article

  • Create macro to move data in a column UP?

    - by user1786695
    I have an excel sheet of which the data was jumbled: for example, the data that should have been in Columns AB and AC were instead in Columns B and C, but on the row after. I have the following written which moved the data from B and C to AB and AC respectively: Dim rCell As Range Dim rRng As Range Set rRng = Sheet1.Range("A:A") i = 1 lastRow = ActiveSheet.Cells(Rows.Count, "A").End(xlUp).Row For Each rCell In rRng.Cells If rCell.Value = "" Then Range("AB" & i) = rCell.Offset(0, 1).Value rCell.Offset(0, 1).ClearContents End If i = i + 1 If i = lastRow + 1 Then Exit Sub End If Next rCell End Sub However, it doesn't fix the problem of the data being on the row BELOW the appropriate row now that they are in the right columns. I am new to VBA Macros so I would appreciate any help to make the data now align. I tried toggling the Offset parameter (-1,0) but it's not working.

    Read the article

  • Using an old PC case and power supply as a HDD Enclosure?

    - by mexiq
    I have 5 HDD and my computer is not handling the situation very well. hehe There are some towers that I can buy to put 4 of my drives out, but I'm thinking that I could use the power source of a failed computer I have and use it to power the 4 (or at least 3) of the drives. The data cables (SATA) will remain connected to the working computer (so no USB solution). The problem is that the power source will not work unless it is connected to the failing computer motherboard. Is there any way I could use the power source without plunging it to the old motherboard? Any "HOW-TO" links may be useful as well.

    Read the article

  • P4 vs. i3/i5 *T in power consumption and performance [migrated]

    - by Walter Zomb
    I am running an Intel P4 prescott with HT on my home server (linux file server on encrypted disks on software-RAID5 and virtualisation host for three further machines). The performance for this purpose is really okay. When the system is idle it consumes about 140W power. I am considering buying a new mainboard for an e.g. Intel i3-2100T or an Intel i5-2390T. Both are low power CPUs with a TDP about 40W. Has anyone experiences how much power a recent mainboard with one of these CPUs an 3-4 'green-energy' disks (6W each) consumes? Do I get underneath the 100W threshold? What's about the performance of these low power CPUs? Are they comparable to an Intel P4 with HT? regards, walter

    Read the article

  • Why does unpartitioned Hitachi HDS5C3020 drive start consuming 50% more power 15 minutes after boot?

    - by Pro Backup
    In a Debian 6.0.6 system there are 74 pieces of 2TB Toshiba DT01ABA200 drives. These drives are identified as Hitachi HDS5C3020BLE630 drives running firmware revision MZ4OAAB0. 64 Drives attached via HP SAS expander cards to an LSI 2008 SAS controller, another 5 drives are connected directly to the mainboard, 4 drives are connected to a Sil based PCI controller and last 1 drive is only powered and has no data cable connected. The controller LSI and Sil card's their onboard BIOS are both disabled and the mpt2sas and sata_sil modules are removed from the Linux debian 2.6.32-5-amd64 #1 SMP Sun Sep 23 10:07:46 UTC 2012 x86_64 GNU/Linux kernel. The mpt2sas module is loaded after boot using a modprobe command in /etc/rc.local. These 74 drives are not partitioned, neither formatted and also not mounted. The system consumes: with 0 drives: 70.6 - 70.9 Watt (also 15 minutes after boot); with 74 drives: 330 - 360 Watt, just after boot (is equivalent to 3.5 - 3.9W per drive in idle state); with 74 drives: 420 - 466 Watt, each time in the 15th minute of uptime (is equivalent to 4.7 - 5.3W per drive in idle state). The drive specification lists 4.7W as read/write, and 3.3W as idle power consumption. The increased power consumption is most likely on the 5V line, because after roughly 1 minute an "over current protection" (OCP) of the power supply (PSU) shuts down the power. The used PSU is a single rail model with an OCP of 122A on the 12V line and 55A on the 5V line. Regression: It doesn't matter whether the drive its APM value is set to disabled or 1 (maximum power saving). The operating system records no read/write activity in /proc/diskstats. The values there are identical (28 read, 0 write operations) as immediately after the modprobe operation. Can't test what happens when booting into the mainboard it's BIOS - to exclude any OS intervention - because the Super Micro X8SI6-F mainboard running firmware 06/27/12 has a bug that incorrectly reads a +74.0 C CPU sensor temperature as "High" in BIOS mode, and shuts down the power after 1 minute. What might be causing the drive read/write activity on all drives in the 15th minute after boot and how to prevent it from happening?

    Read the article

  • Is the APC BR700G UPS (or similar) compatible with Active PFC power supplies?

    - by David Zaslavsky
    I'm looking at getting a UPS for my home computer. So far the APC BR700G looks very promising, except for one thing: one of the reviews on Newegg says that this UPS does not work with a power supply with Active PFC. Pros: Unit looks great, built well, very heavy, was excited to use it. Cons: Didn't research enough - many newer power supplies like my corsair 750w (and yes dells and other mainstreamers sell them too) that I bought last year have a feature called active pfc (power factor corrected). The signal for this backup battery doesn't fully support that feature and can cause issues. You can find an article on APCs site if you search their user forums for PFC. And the power supply in my computer is, in fact, an Active PFC PSU. I've already found one answer on this site claiming that it's not an issue, that "most quality supplies these days have PFC and work just fine with a UPS." That disagrees with the review on Newegg. Can someone explain this discrepancy? Also, what is it exactly about a UPS that makes it incompatible with an Active PFC PSU? (if anything) Is there some way to tell based on the technical specifications, or do I just have to hunt for reviews online to avoid wasting my money? While any input would be appreciated, I would prefer to get an answer from someone with actual experience with similar UPS's and Active PFC power supplies, who can tell me whether it works or not.

    Read the article

  • Reseting Macbook Pro keyboard and trackpad's power usage on Windows?

    - by Dan the Man
    I recently installed a utitlity for Windows (ASUS Ai Charger) which modifies the USB ports on the computer to output more power (for charging iPads, etc). The problem is, I believe it is also giving more power to my keyboard and trackpad. And now, neither devices are working at all, yet they work on Mac OS X. So does anyone know the amount of power MacBook Pro (2007) keyboards and trackpads use, and how I can set these settings in Windows 7?

    Read the article

  • Suspected power supply issue? PC repeatedly whirs for some seconds and then dies.

    - by benwebdev
    I've come home today and switched on the PC I've built a few months ago only for the machine to whir for a few short seconds and then die. It repeats this until I disconnect the power lead. Nothing is output to the screen and this cut out happens very quickly after switching it on. What could this be and how could it be fixed? Is it the power supply? I'm in despair :-( My spec is below, everything is new and was bought and assembled within the last 6months, system has been fantastic until now. Power Supply: 620W CoolerMaster Real Power M620 Motherboard: Gigabyte GA-X58A-UD3R Intel X58 (Socket 1366) DDR3 Processor: Intel Core i7 930 2.80GHz @ 4.00GHz RAM: 6GB DDR3 OS Windows 7 64bit Sapphire HD 5770 Vapor-X 1GB Graphics card 1TB Hitachi HDD 720GB Seagate Barracuda HDD 350GB Seagate Barracuda HDD EMu 0404 PCI Soundcard D-Link PCI-E wireless card Samsung DVD RW drive

    Read the article

  • Is it safe to use an IDE to SATA power adapter for an extended period of time?

    - by qwertymk
    I just bought a computer from HP and they failed to include SATA power connectors with the power supply other then the one HD and DVD drive. Meanwhile I have two IDE to SATA power adapters that came with my "USB 2.0 to SATA/IDE cable" http://www.amazon.com/USB-2-0-SATA-Cable-Adapter/dp/B001OORN06 3rd pic on the left. I was wondering if I would just open up my computer and use it to plug it my SATA drives to the IDE power sources and mount it to the motherboard, would it damage my drives in the long run or have any other significant effects. A friend told me he knows people who have had their HD burn out because of this

    Read the article

  • What are the essential considerations for setting up systems in a location with unreliable power?

    - by dunxd
    I deal with a lot of remote offices located in parts of the world where the local grid power supply is unreliable. Power can go off anytime with no warning, with outages ranging from minutes to days Power fluctuation is wild, with spikes and brown outs Currently the offices will have some or all of the following: A generator, with an inverter, or some sort of manual switch A big UPS or battery array connecting a number of devices Several smaller APC UPS with computers attached Low cost Voltage Regulators sometimes connected between mains and UPS or device. I know that each of these things needs to be appropriately rated for the equipment to which it is connected (although I am not sure how to calculate the correct rating). The offices will generally have the following equipment (in varying quantities): some sort of internet connection device (VSAT router, ADSL modem, WiMax router) Cisco ASA 5505 firewall a bunch of PCs printers one server I don't seek to replace the advice of an electrician, but in some of these locations they only answer the questions you ask them, so I need to make sure I have enough understanding of the essentials to protect equipment from damage, and possibly get through some power cuts.

    Read the article

  • Will an Australian power adapter with an American plug charge a Laptop safely?

    - by leeand00
    A friend of mine has a laptop that she brought from Egypt to America, and she is afraid to charge it. She told me the laptop was purchased in Australia and it has a plug like this: And the power adapter reads The relevant text on the power brick reads: Wide Range Input 100-240V-1.7A(1.7A) 50-60Hz 18.5(18.5V) = 3.5A(3.5A) 65W The other end of the power adapter looks like this: Laptop make and model: HP Pavilion dv5-1045TX

    Read the article

  • Does anyone have database, programming language/framework suggestions for a GUI point of sale system

    - by Jason Down
    Our company has a point of sale system with many extras, such as ordering and receiving functionality, sales and order history etc. Our main issue is that the system was not designed properly from the ground up, so it takes too long to make fixes and handle requests from our customers. Also, the current technology we are using (Progress database, Progress 4GL for the language) incurs quite a bit of licensing expenses on our customers due to mutli-user license fees for database connections etc. After a lot of discussion it is looking like we will probably start over from scratch (while maintaining the current product at least for the time being). We are looking for a couple of things: Create the system with a nice GUI front end (it is currently CHUI and the application was not built in a way that allows us to redesign the front end... no layering or separation of business logic and gui...shudder). Create the system with the ability to modularize different functionality so the product doesn't have to include all features. This would keep the cost down for our current customers that want basic functionality and a lower price tag. The bells and whistles would be available for those that would want them. Use proper design patterns to make the product easy to add or change any part at any time (i.e. change the database or change the front end without needing to rewrite the application or most of it). This is a problem today because the Progress 4GL code is directly compiled against the database. Small changes in the database requires lots of code recompiling. Our new system will be Linux based, with a possibility of a client application providing functionality from one or more windows boxes. So what I'm looking for is any suggestions on which database and/or framework or programming language(s) someone might recommend for this sort of product. Anyone that has experience in this field might be able to point us in the right direction or even have some ideas of what to avoid. We have considered .NET and SQL Express (we don't need an enterprise level DB), but that would limit us to windows (as far as I know anyway). I have heard of Mono for writing .NET code in a Linux environment, but I don't know much about it yet. We've also considered a Java and MySql based implementation. To summarize we are looking to do the following: Keep licensing costs down on the technology we will use to develop the product (Oracle, yikes! MySQL, nice.) Deliver a solution that is easily maintainable and supportable. A solution that has a component capable of running on "old" hardware through a CHUI front end. (some of our customers have 40+ terminals which would be a ton of cash in order to convert over to a PC). Suggestions would be appreciated. Thanks [UPDATE] I should note that we are currently performing a total cost analysis. This question is intended to give us a couple of "educated" options to look into to include in or analysis. Anyone who could share experiences/suggestions about client/server setups would be appreciated (not just those who have experience with point of sale systems... that would just be a bonus).

    Read the article

  • Open excel 2007 excel files and save as 97-2003 formats in VBA

    - by ABB
    I have a weird situation where I have a set of excel files, all having the extension .xls., in a directory where I can open all of them just fine in Excel 2007. The odd thing is that I cannot open them in Excel 2003, on the same machine, without opening the file first in 2007 and going and saving the file as an "Excel 97-2003 Workbook". Before I save the file as an "Excel 97-2003 Workbook" from Excel 2007, when I open the excel files in 2003 I get the error that the file is not in a recognizable format. So my question is: if I already have the excel file opened in 2007 and I already have the file name of the open file stored in a variable, programatically how can I mimic the action of going up to the "office button" in the upper right and selecting, "save as" and then selecting "Excel 97-2003 Workbook"? I've tried something like the below but it does not save the file at all: ActiveWorkbook.SaveAs TempFilePath & TempFileName & ".xls", FileFormat:=56 Thanks for any help or guidance!

    Read the article

  • VBA ActiveX controls grow in size over Remote Desktop Connection

    - by Alistair Knock
    We have an Excel workbook with a number of ActiveX controls, running in Excel 2003 on Windows XP. When connecting using Remote Desktop, the ActiveX controls change font, sometimes font size, and sometimes orientation (in the case of a spinner control). This happens on first connection and also as the workbook is used - some of the controls then enlarge in size, often overlapping other controls and part of the workbook. I read somewhere this may be caused by improper connection management (not closing them) leading to increasing memory usage; are there other reasons why the display is so different over Remote Desktop and are there workarounds? (the properties of each control usually remain the same, so force-resizing them doesn't always have an effect)

    Read the article

  • Excel VBA - How to copy/transpose multiple columns record into individual single row

    - by larry
    I'm working on data migration, need some help on doing a macro to copy/transpose multiple columns record into individual single row. There are also a "tag" in the first row, which indicates the columns that should not be included in the copy/transpose. From: Tag x Name Jan Feb Mar Apr Larry 2 20 34 56 Harry 3 45 77 88 Marry 5 66 44 33 To: Larry Jan 2 Larry Feb 20 Larry Apr 56 Harry Jan 3 Harry Feb 45 Harry Apr 88 Marry Jan 5 Marry Feb 66 Marry Apr 33 The "Mar" data was omitted due to there's a tag (X) above it. The data might be near hundred columns (few years), and some of the months need to be omitted. Any expert able to help on this? I had been spending whole day cracking my head on this. Worse come to worse I might have to manually copy and paste, that would probably took me a decade.

    Read the article

  • VBA text box input mask

    - by Jaison
    I have two validation for date and time as below in text boxes: 00/00\ 00:00;0;0;_ It will take (dd/mm hh:mm) and works fine But sometimes i put 34/34 56:78 it will take , But it shouldn't Date sholdnot go beyond 31, month 12 time 24 and minute 59 Please help

    Read the article

  • Excel VBA to Update SQL Table

    - by user307655
    Hi All, I have a small excel program that is use to upload data to an SQL server. This has been working well for a while. My problem now is that I would like to offer to users a function to update an existing record in SQL. As each row on this table has a unique id columne. There is a column call UID which is the primary key. This is part of the code currently to upload new data: Set Cn = New ADODB.Connection Cn.Open "Driver={SQL Server};Server=" & ServerName & ";Database=" & DatabaseName & _ ";Uid=" & UserID & ";Pwd=" & Password & ";" rs.Open TableName, Cn, adOpenKeyset, adLockOptimistic For RowCounter = StartRow To EndRow rs.AddNew For ColCounter = 1 To NoOfFields rs(ColCounter - 1) = shtSheetToWork.Cells(RowCounter, ColCounter) Next ColCounter Next RowCounter rs.UpdateBatch ' Tidy up rs.Close Set rs = Nothing Cn.Close Set Cn = Nothing Is there anyway i can modify this code to update a particular UID rather than importing new records? Thanks again for your help

    Read the article

  • VBA-Sorting the data in a listbox, sort works but data in listbox not changed

    - by Mike Clemens
    A listbox is passed, the data placed in an array, the array is sort and then the data is placed back in the listbox. The part that does work is putting the data back in the listbox. Its like the listbox is being passed by value instead of by ref. Here's the sub that does the sort and the line of code that calls the sort sub. Private Sub SortListBox(ByRef LB As MSForms.ListBox) Dim First As Integer Dim Last As Integer Dim NumItems As Integer Dim i As Integer Dim j As Integer Dim Temp As String Dim TempArray() As Variant ReDim TempArray(LB.ListCount) First = LBound(TempArray) ' this works correctly Last = UBound(TempArray) - 1 ' this works correctly For i = First To Last TempArray(i) = LB.List(i) ' this works correctly Next i For i = First To Last For j = i + 1 To Last If TempArray(i) > TempArray(j) Then Temp = TempArray(j) TempArray(j) = TempArray(i) TempArray(i) = Temp End If Next j Next i ! data is now sorted LB.Clear ! this doesn't clear the items in the listbox For i = First To Last LB.AddItem TempArray(i) ! this doesn't work either Next i End Sub Private Sub InitializeForm() ' There's code here to put data in the list box Call SortListBox(FieldSelect.CompleteList) End Sub Thanks for your help.

    Read the article

  • In Excel, VBA - How can we lock resizing of a rectangle

    - by sruthi
    I have an excel sheet that contains two rectangles and text in other cells. I need to allow users to only edit the text in the rectangle. They should not be able to change the size of the object. Applying lock on the rectangle locks the object as well as the text. Does anyone know how I can achieve this?

    Read the article

  • Excel VBA Text To Column

    - by Pat
    This is what I currently have: H101 John Doe Jane Doe Jack Doe H102 John Smith Jane Smith Katie Smith Jack Smith And here is what I want: H101 John Doe H101 Jane Doe H101 Jack Doe H102 John Smith H102 Jane Smith H102 Katie Smith H102 Jack Smith Obviously I want to do this on a bigger scale. The number of columns is between 1 & 6, so I cant limit it that way. I was able to get a script that allows me to put each individual on one row. However, I am having a hard time getting the first column to copy over to each row. Sub ToOneColumn() Dim i As Long, k As Long, j As Integer Application.ScreenUpdating = False Columns(2).Insert i = 0 k = 1 While Not IsEmpty(Cells(k, 3)) j = 3 While Not IsEmpty(Cells(k, j)) i = i + 1 Cells(i, 1) = Cells(k, 1) //CODE IN QUESTION Cells(i, 2) = Cells(k, j) Cells(k, j).Clear j = j + 1 Wend k = k + 1 Wend Application.ScreenUpdating = True End Sub Like I said, it was working fine to get everyone each on their own row, but can't figure out how to get that first column. It seems like it should be so simple, but it's bugging me. Any help is greatly appreciated.

    Read the article

  • Is there a JSON parser for VB6 / VBA?

    - by Ben McCormack
    I'm trying to consume a web service in VB6. The service (which I control) currently can return a SOAP/XML message or JSON. I'm having a really difficult time figuring out if VB6's SOAP type (version 1) can handle a returned object (as opposed to simple types like string, int, etc.). So far I can't figure out what I need to do to get VB6 to play with returned objects. So I thought I might serialize the response in the web service as a JSON string. Does a JSON parser exist for VB6?

    Read the article

  • Access VBA sub with form as parameter doesn't alter the form

    - by Ski
    I have a Microsoft Access 2003 file with various tables of data. Each table also has a duplicate of it, with the name '[original table name]_working'. Depending on the user's choices in the switchboard, the form the user choose to view must switch its recordsource table to the working table. I refactored the relevant code to do such a thing into the following function today: Public Sub SetFormToWorking(ByRef frm As Form) With frm .RecordSource = rst![Argument] & "_working" .Requery Dim itm As Variant For Each itm In .Controls If TypeOf itm Is subForm Then With Item Dim childFields As Variant, masterFields As Variant childFields = .LinkChildFields masterFields = .LinkMasterFields .Form.RecordSource = .Form.RecordSource & "_working" .LinkChildFields = childFields .LinkMasterFields = masterFields .Form.Requery End With End If Next End With End Sub The lines of code that call the function look like this: SetFormToWorking Forms(rst![Argument]) and SetFormToWorking Forms(cmbTblList) For some reason, the above function doesn't change the recordsource for the form. I added the 'ByRef' keyword to the parameter just to be certain that it was passing by reference, but no dice. Hopefully someone here can tell me what I've done wrong?

    Read the article

< Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >