Search Results

Search found 11246 results on 450 pages for 'power supply unit'.

Page 24/450 | < Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >

  • Unit Testing the Use of TransactionScope

    - by Randolpho
    The preamble: I have designed a strongly interfaced and fully mockable data layer class that expects the business layer to create a TransactionScope when multiple calls should be included in a single transaction. The problem: I would like to unit test that my business layer makes use of a TransactionScope object when I expect it to. Unfortunately, the standard pattern for using TransactionScope is a follows: using(var scope = new TransactionScope()) { // transactional methods datalayer.InsertFoo(); datalayer.InsertBar(); scope.Complete(); } While this is a really great pattern in terms of usability for the programmer, testing that it's done seems... unpossible to me. I cannot detect that a transient object has been instantiated, let alone mock it to determine that a method was called on it. Yet my goal for coverage implies that I must. The Question: How can I go about building unit tests that ensure TransactionScope is used appropriately according to the standard pattern? Final Thoughts: I've considered a solution that would certainly provide the coverage I need, but have rejected it as overly complex and not conforming to the standard TransactionScope pattern. It involves adding a CreateTransactionScope method on my data layer object that returns an instance of TransactionScope. But because TransactionScope contains constructor logic and non-virtual methods and is therefore difficult if not impossible to mock, CreateTransactionScope would return an instance of DataLayerTransactionScope which would be a mockable facade into TransactionScope. While this might do the job it's complex and I would prefer to use the standard pattern. Is there a better way?

    Read the article

  • How to unit test generic classes

    - by Rowland Shaw
    I'm trying to set up some unit tests for an existing compact framework class library. However, I've fallen at the first hurdle, where it appears that the test framework is unable to load the types involved (even though they're both in the class library being tested) Test method MyLibrary.Tests.MyGenericClassTest.MyMethodTest threw exception: System.MissingMethodException: Could not load type 'MyLibrary.MyType' from assembly 'MyLibrary, Version=1.0.3778.36113, Culture=neutral, PublicKeyToken=null'.. My code is loosely: public class MyGenericClass<T> : List<T> where T : MyType, new() { public bool MyMethod(T foo) { throw new NotImplementedException(); } } With test methods: public void MyMethodTestHelper<T>() where T : MyType, new() { MyGenericClass<T> target = new MyGenericClass<T>(); foo = new T(); expected = true; actual = target.MyMethod(foo); Assert.AreEqual(expected, actual); } [TestMethod()] public void MyMethodTest() { MyMethodTestHelper<MyType>(); } I'm a bit stumped though, as I can't even get it to break in the debugger to get to the inner exception, so what else do I check? EDIT this does seem to be something specific to the Compact Framework - recompiling the class libraries and the unit tests for the full framework, gives the expected output (i.e. the debugger stops when I'm going to throw a NotImplementedException).

    Read the article

  • C++ and Dependency Injection in unit testing

    - by lhumongous
    Suppose I have a C++ class like so: class A { public: A() { } void SetNewB( const B& _b ) { m_B = _b; } private: B m_B; } In order to unit test something like this, I would have to break A's dependency on B. Since class A holds onto an actual object and not a pointer, I would have to refactor this code to take a pointer. Additionally, I would need to create a parent interface class for B so I can pass in my own fake of B when I test SetNewB. In this case, doesn't unit testing with dependency injection further complicate the existing code? If I make B a pointer, I'm now introducing heap allocation, and some piece of code is now responsible for cleaning it up (unless I use ref counted pointers). Additionally, if B is a rather trivial class with only a couple of member variables and functions, why introduce a whole new interface for it instead of just testing with an instance of B? I suppose you could make the argument that it would be easier to refactor A by using an interface. But are there some cases where two classes might need to be tightly coupled?

    Read the article

  • Unit Testing Interfaces in Python

    - by Nicholas Mancuso
    I am currently learning python in preperation for a class over the summer and have gotten started by implementing different types of heaps and priority based data structures. I began to write a unit test suite for the project but ran into difficulties into creating a generic unit test that only tests the interface and is oblivious of the actual implementation. I am wondering if it is possible to do something like this.. suite = HeapTestSuite(BinaryHeap()) suite.run() suite = HeapTestSuite(BinomialHeap()) suite.run() What I am currently doing just feels... wrong (multiple inheritance? ACK!).. class TestHeap: def reset_heap(self): self.heap = None def test_insert(self): self.reset_heap() #test that insert doesnt throw an exception... for x in self.inseq: self.heap.insert(x) def test_delete(self): #assert we get the first value we put in self.reset_heap() self.heap.insert(5) self.assertEquals(5, self.heap.delete_min()) #harder test. put in sequence in and check that it comes out right self.reset_heap() for x in self.inseq: self.heap.insert(x) for x in xrange(len(self.inseq)): val = self.heap.delete_min() self.assertEquals(val, x) class BinaryHeapTest(TestHeap, unittest.TestCase): def setUp(self): self.inseq = range(99, -1, -1) self.heap = BinaryHeap() def reset_heap(self): self.heap = BinaryHeap() class BinomialHeapTest(TestHeap, unittest.TestCase): def setUp(self): self.inseq = range(99, -1, -1) self.heap = BinomialHeap() def reset_heap(self): self.heap = BinomialHeap() if __name__ == '__main__': unittest.main()

    Read the article

  • Migrating from IBM AIX/DB2 Power systems to Oracle Technologies

    - by zeynep.koch(at)oracle.com
    If you are planning to migrate from  IBM DB2 on AIX Power Systems to more open and better-performing computing environment--one that offers enhanced flexibility, clustering, availability, and security, as well as lower maintenance than download this guide that outlines migrating to Oracle Database 11g and Oracle Linux running on Oracle's Sun Fire X4800 server.This guide shows you how to:Move sample applications with an IBM DB2 on an IBM Power System to Oracle Database 11g Release 2Install Oracle Linux and Oracle Database Release 2 on the Oracle's Sun Fire X4800 serverMigrate user databases from the IBM Power System to Oracle's Sun Fire X4800 serverDownload

    Read the article

  • SPARC Power Management Article at OTN

    - by nospam(at)example.com (Joerg Moellenkamp)
    My colleague Karoly Vegh pointed in a tweet to a really interesting article about the usage of Power Management of SPARC T-series systems. The article explains how to use the power management, how it works, what it's able to do and how to use it in a dynamic fashion according to anticipated load patterns. You find the article "How to Use the Power Management Controls on SPARC Servers" written by by Bruce Evans, Julia Harper, and Terry Whatley on OTN.

    Read the article

  • What type of code is suitable for unit testing?

    - by RPK
    In Test Driven Development, what type of code is testable? I am using a Micro-ORM (PetaPoco) and I have several methods that interact with the database like: AddCustomer UpdateRecord etc. I want to know how to write a test for these methods. I searched YouTube for videos on writing a test for DAL, but I didn't find any. I want to know which method or class is testable and how to write a test before writing the code itself.

    Read the article

  • Why Ultra-Low Power Computing Will Change Everything

    - by Tori Wieldt
    The ARM TechCon keynote "Why Ultra-Low Power Computing Will Change Everything" was anything but low-powered. The speaker, Dr. Johnathan Koomey, knows his subject: he is a Consulting Professor at Stanford University, worked for more than two decades at Lawrence Berkeley National Laboratory, and has been a visiting professor at Stanford University, Yale University, and UC Berkeley's Energy and Resources Group. His current focus is creating a standard (computations per kilowatt hour) and measuring computer energy consumption over time. The trends are impressive: energy consumption has halved every 1.5 years for the last 60 years. Battery life has made roughly a 10x improvement each decade since 1960. It's these improvements that have made laptops and cell phones possible. What does the future hold? Dr. Koomey said that in the past, the race by chip manufacturers was to create the fastest computer, but the priorities have now changed. New computers are tiny, smart, connected and cheap. "You can't underestimate the importance of a shift in industry focus from raw performance to power efficiency for mobile devices," he said. There is also a confluence of trends in computing, communications, sensors, and controls. The challenge is how to reduce the power requirements for these tiny devices. Alternate sources of power that are being explored are light, heat, motion, and even blood sugar. The University of Michigan has produced a miniature sensor that harnesses solar energy and could last for years without needing to be replaced. Also, the University of Washington has created a sensor that scavenges power from existing radio and TV signals.Specific devices designed for a purpose are much more efficient than general purpose computers. With all these sensors, instead of big data, developers should focus on nano-data, personalized information that will adjust the lights in a room, a machine, a variable sign, etc.Dr. Koomey showed some examples:The Proteus Digital Health Feedback System, an ingestible sensor that transmits when a patient has taken their medicine and is powered by their stomach juices. (Gives "powered by you" a whole new meaning!) Streetline Parking Systems, that provide real-time data about available parking spaces. The information can be sent to your phone or update parking signs around the city to point to areas with available spaces. Less driving around looking for parking spaces!The BigBelly trash system that uses solar power, compacts trash, and sends a text message when it is full. This dramatically reduces the number of times a truck has to come to pick up trash, freeing up resources and slashing fuel costs. This is a classic example of the efficiency of moving "bits not atoms." But researchers are approaching the physical limits of sensors, Dr. Kommey explained. With the current rate of technology improvement, they'll reach the three-atom transistor by 2041. Once they hit that wall, it will force a revolution they way we do computing. But wait, researchers at Purdue University and the University of New South Wales are both working on a reliable one-atom transistors! Other researchers are working on "approximate computing" that will reduce computing requirements drastically. So it's unclear where the wall actually is. In the meantime, as Dr. Koomey promised, ultra-low power computing will change everything.

    Read the article

  • Problem with Graphics Card, Power Supply or Mother Board?

    - by Rick Siegert
    I have a problem that is driving me to the edge. My graphics card periodically looses power for a moment, then comes back. Once in a while it takes much longer, like 5 minutes. I have always tried rebooting during that period, since I don't know then. Black screen, with a no power message across my monitor. All equipment is only a few months old. The Motherboard is a few months old, MSI N9A2 Platinum Revision 1 (AMD). The Video Card is a Gigabyte Radeon HD 4850 1GB. The power supply is an Ultra 700w My OS is Xp Pro, sp3 Any ideas or suggestions how to solve this

    Read the article

  • Do you write common pre-conditions for a large number of unit test cases ?

    - by Vinoth Kumar
    I have heard/read writing common pre-conditions for a large number of test cases is a bad thing, since this dependency may cause large number of test cases to fail if something changes . What are your thoughts on it ? If this is so , then what exactly is the purpose of setUp() method in Junit that runs before each test case ? If the same code inside setUp() runs before each test case , why cant it run only once before running all the test cases together ?

    Read the article

  • Calculating the "power" of a player in a "Defend Your Castle" type game

    - by Jesse Emond
    I'm a making a "Defend Your Castle" type game, where each player has a castle and must send units to destroy the opponent's castle. It looks like this (and yeah, this is the actual game, not a quick paint drawing..): Now, I'm trying to implement the AI of the opponent, and I'd like to create 4 different AI levels: Easy, Normal, Hard and Hardcore. I've never made any "serious" AI before and I'd like to create a quite complete one this time. My idea is to calculate a player's "power" score, based on the current health of its castle and the individual "power" score of its units. Then, the AI would just try to keep a score close to the player's one(Easy would stay below it, Normal would stay near it and Hard would try to get above it). But I just don't know how to calculate a player's power score. There are just too many variables to take into account and I don't know how to properly use them to create one significant number(the power level). Could anyone help me out on this one? Here are the variables that should influence a player's power score: Current castle health, the unit's total health, damage, speed and attack range. Also, the player can have increased Income(the money bag), damage(the + Damage) and speed(the + speed)... How could I include them in the score? I'm really stuck here... Or is there an other way that I could implement AI for this type of game? Thanks for your precious time.

    Read the article

  • Linux kernel regression on power usage

    - by dago
    Webupd8 reported this power management fix for the 2.6.38 Linux kernel regression: Add the following to the boot grub line "pcie_aspm=force" My question - how does this suggested fix differ from this hint from powertop: Suggestion: Enable Device Power Management by pressing the P key, which execute the following action: find /sys/devices/pci* -path "*power/control" -exec bash -c "echo auto > '{}'" \;

    Read the article

  • New Best-in-Class Solutions in Supply Chain Planning - Part 2

    Hear Nadeem Syed, Oracle Group Vice President, Advanced Planning Products discusst Oracle's recently announced best-in-class Supply Chain Planning solutions: Advanced Planning Command Center, Demand Signal Repository, Spare Parts Planning and Manufacturing Operations Center. Gain an understanding of the capabilities of these ground-breaking planning solutions and what types of enterprises can benefit from them.

    Read the article

  • Tool to convert Textures to power of two?

    - by 3nixios
    I'm currently porting a game to a new platform, the problem being that the old platform accepted non power of two textures and this new platform doesn't. To add to the headache, the new platform has much less memory so we want to use the tools provided by the vendor to compress them; which of course only takes power of two textures. The current workflow is to convert the non power of tho textures to dds with 'texconv', then use the vendors compression tools in a batch. So, does anyone know of a tool to convert textures to their nearest 'power of two' counterparts? Thanks

    Read the article

  • Does a Samsung G3 Station external hard drive stop working when power supply is too high?

    - by Cacovsky
    I have a Samsung G3 Station 2TB external hard drive (link to PDF specs here). It was working perfectly when I accidentally plugged it in my notebook's power source. The notebook's power source is 19V/3.42A. The hard drive's is 12V/2A and I know that, inside its case, there is regular 2TB SATA drive, along with some sort of adapter. Does this adapter has some kind of power protection? I opened the case and the hard drive board smells bad. Does my data is forever lost or can I replace its board?

    Read the article

  • What if I can't make my unit test fail in "Red, Green, Refactor" of TDD?

    - by Joshua Harris
    So let's say that I have a test: @Test public void MoveY_MoveZero_DoesNotMove() { Point p = new Point(50.0, 50.0); p.MoveY(0.0); Assert.assertAreEqual(50.0, p.Y); } This test then causes me to create the class Point: public class Point { double X; double Y; public void MoveY(double yDisplace) { throw new NotYetImplementedException(); } } Ok. It fails. Good. Then I remove the exception and I get green. Great, but of course I need to test if it changes value. So I write a test that calls p.MoveY(10.0) and checks if p.Y is equal to 60.0. It fails, so then I change the function to look like so: public void MoveY(double yDisplace) { Y += yDisplace; } Great, now I have green again and I can move on. I've tested not moving and moving in the positive direction, so naturally I should test a negative value. The only problem with this test is that if I wrote the test correctly, then it doesn't fail at first. That means that I didn't fit the principle of "Red, Green, Refactor." Of course, This is a first-world problem of TDD, but getting a fail at first is helpful in that it shows that your test can fail. Otherwise this seemingly innocent test that is just passing for incorrect reasons could fail later because it was written wrong. That might not be a problem if it happened 5 minutes later, but what if it happens to the poor-sap that inheirited your code two years later. What he knows is that MoveY does not work with negative values because that is what the test is telling him. But, it really could work and just be a bug in the test. I don't think that would happen in this particular case because the code sample is so simple, but if it were a large complicated system that might not be the case. It seems crazy to say that I want to fail my tests, but that is an important step in TDD, for good reasons.

    Read the article

  • Function Folding in #PowerQuery

    - by Darren Gosbell
    Originally posted on: http://geekswithblogs.net/darrengosbell/archive/2014/05/16/function-folding-in-powerquery.aspxLooking at a typical Power Query query you will noticed that it's made up of a number of small steps. As an example take a look at the query I did in my previous post about joining a fact table to a slowly changing dimension. It was roughly built up of the following steps: Get all records from the fact table Get all records from the dimension table do an outer join between these two tables on the business key (resulting in an increase in the row count as there are multiple records in the dimension table for each business key) Filter out the excess rows introduced in step 3 remove extra columns that are not required in the final result set. If Power Query was to execute a query like this literally, following the same steps in the same order it would not be overly efficient. Particularly if your two source tables were quite large. However Power Query has a feature called function folding where it can take a number of these small steps and push them down to the data source. The degree of function folding that can be performed depends on the data source, As you might expect, relational data sources like SQL Server, Oracle and Teradata support folding, but so do some of the other sources like OData, Exchange and Active Directory. To explore how this works I took the data from my previous post and loaded it into a SQL database. Then I converted my Power Query expression to source it's data from that database. Below is the resulting Power Query which I edited by hand so that the whole thing can be shown in a single expression: let     SqlSource = Sql.Database("localhost", "PowerQueryTest"),     BU = SqlSource{[Schema="dbo",Item="BU"]}[Data],     Fact = SqlSource{[Schema="dbo",Item="fact"]}[Data],     Source = Table.NestedJoin(Fact,{"BU_Code"},BU,{"BU_Code"},"NewColumn"),     LeftJoin = Table.ExpandTableColumn(Source, "NewColumn"                                   , {"BU_Key", "StartDate", "EndDate"}                                   , {"BU_Key", "StartDate", "EndDate"}),     BetweenFilter = Table.SelectRows(LeftJoin, each (([Date] >= [StartDate]) and ([Date] <= [EndDate])) ),     RemovedColumns = Table.RemoveColumns(BetweenFilter,{"StartDate", "EndDate"}) in     RemovedColumns If the above query was run step by step in a literal fashion you would expect it to run two queries against the SQL database doing "SELECT * …" from both tables. However a profiler trace shows just the following single SQL query: select [_].[BU_Code],     [_].[Date],     [_].[Amount],     [_].[BU_Key] from (     select [$Outer].[BU_Code],         [$Outer].[Date],         [$Outer].[Amount],         [$Inner].[BU_Key],         [$Inner].[StartDate],         [$Inner].[EndDate]     from [dbo].[fact] as [$Outer]     left outer join     (         select [_].[BU_Key] as [BU_Key],             [_].[BU_Code] as [BU_Code2],             [_].[BU_Name] as [BU_Name],             [_].[StartDate] as [StartDate],             [_].[EndDate] as [EndDate]         from [dbo].[BU] as [_]     ) as [$Inner] on ([$Outer].[BU_Code] = [$Inner].[BU_Code2] or [$Outer].[BU_Code] is null and [$Inner].[BU_Code2] is null) ) as [_] where [_].[Date] >= [_].[StartDate] and [_].[Date] <= [_].[EndDate] The resulting query is a little strange, you can probably tell that it was generated programmatically. But if you look closely you'll notice that every single part of the Power Query formula has been pushed down to SQL Server. Power Query itself ends up just constructing the query and passing the results back to Excel, it does not do any of the data transformation steps itself. So now you can feel a bit more comfortable showing Power Query to your less technical Colleagues knowing that the tool will do it's best fold all the  small steps in Power Query down the most efficient query that it can against the source systems.

    Read the article

  • Power supply issue? New Radeon5850's fan runs at full speed and PC doesn't boot.

    - by Kris
    I recently bought a new ASUS EAH5850 graphics board. I installed it a custom PC which had an ASUS p5n-e SLI mobo along with a 500w Thermaltake W0093RU power supply. Sometimes when doing a cold boot the 5850's fan will run at full speed and the PC will not boot. Powering off by holding down the power button and powering back on sometimes remedies the situation and everything boots normally. Warm reboots also never seem to have problems. For some reason though cold boots almost always do. Another issue I notice is that when the PC does boot normally it takes longer (+30 secs) to POST than with my last video card. I flashed the mobo with the latest available BIOS but it had no effect. Is my problem a power issue or incompatible motherboard or something else I'm missing?

    Read the article

  • New Best-in-Class Solutions in Supply Chain Planning - Part 1

    Hear Nadeem Syed, Oracle Group Vice President, Advanced Planning Products discusst Oracle's recently announced best-in-class Supply Chain Planning solutions: Advanced Planning Command Center, Demand Signal Repository, Spare Parts Planning and Manufacturing Operations Center. Gain an understanding of the capabilities of these ground-breaking planning solutions and what types of enterprises can benefit from them.

    Read the article

  • CTP for Power View and SSAS Multidimensional Cubes

    - by Greg Low
    When Power View appeared, one of the big outcries was "but what about connecting to existing cubes!".Great to see that the SQL Server team have addressed that. A CTP that allows connecting Power View to SSAS Multidimensional cubes is now available:http://blogs.msdn.com/b/analysisservices/archive/2012/11/29/power-view-for-multidimensional-models-preview.aspxHelp the team get this out the door by trying it and providing feedback.

    Read the article

  • Ubuntu 12.04 does not power off

    - by G K
    I'm not able to power off Ubuntu, which was working fine a couple of days ago. When I click shut down, a blank screen appears and stays like that forever. It does not power off by itself and I'm forced to physically power off using the power button. I've even tried 'sudo shutdown now' and 'sudo shutdown -h now' and both don't seem to work! Please suggest some fix for this problem. Thanx in advance. Edit: Restart works fine. Also 'sudo poweroff' doesn't work!

    Read the article

  • Power View Infrastructure Configuration and Installation: Step-by-Step and Scripts

    This document contains step-by-step instructions for installing and testing the Microsoft Business Intelligence infrastructure based on SQL Server 2012 and SharePoint 2010, focused on SQL Server 2012 Reporting Services with Power View. This document describes how to completely install the following scenarios: a standalone instance of SharePoint and Power View with all required components; a new SharePoint farm with the Power View infrastructure; a server with the Power View infrastructure joined to an existing SharePoint farm; installation on a separate computer of client tools; installation of a tabular instance of Analysis Services on a separate instance; and configuration of single sign-on access for double-hop scenarios with and without Kerberos. Scripts are provided for all/most scenarios.

    Read the article

  • What actions does Ubuntu trigger when battery is low?

    - by blueyed
    When the battery is low, the screen gets dimmed after a few seconds already. This appears to be some special power-saving mode, and might be related to the time in org.gnome.settings-daemon.plugins.power.time-low (1200 seconds (20 minutes) the default). While this seems to get triggered by gnome-settings-daemon, I wonder what else Ubuntu does when this happens (e.g. via DBus listeners), or other event listeners that look for a "low battery" state. It seems like something in this regard causes Ubuntu / X / the system to behave more sluggish afterwards (when the laptop is on AC again), and I would like to look into what might be causing this. I could not find anything related via dconf-editor, e.g. in org.gnome.settings-daemon.plugins.power. It appears to get setup via idle_configure in plugins/power/gsd-power-manager.c, but it's probably something more related to something that listens on the DBus interface, which gets notified via e.g.: if (!g_dbus_connection_emit_signal (manager->priv->connection, NULL, GSD_POWER_DBUS_PATH, "org.freedesktop.DBus.Properties", "PropertiesChanged", props_changed, &error)) I could imagine that some "power saving" property gets set, but not unset when AC is available anymore and/or the battery is not low anymore. I have looked at the CPU governor setting (/sys/devices/system/cpu/cpu*/cpufreq/scaling_governor), but it was ondemand. I am using gnome-settings-daemon with awesomeWM on Ubuntu 14.04. gnome-settings-daemon=3.8.6.1-0ubuntu11.1 I've also compared gsd's plugins/power/gsd-power-manager.c with the one from Debian's gnome-settings-daemon-3.12.1, but could not find anything obvious that might have been fixed/changed in this regard. I have managed to trigger the gnome-power-manager's gnome-settings plugin (which dims the screen etc), by patching upower and use it after killing the system's upower daemon. (note that it's probably only energy that is being used by gpm to calculate it by itself). It does not make the system become sluggish.. OTOH I have not heard the speaker's beeping, which might come from the BIOS, which might be involved here, too - or other programs using the kernel's interface on /sys/class/power_supply/BAT0/. --- src/linux/up-device-supply.c.orig 2014-06-07 16:48:32.735920661 +0200 +++ src/linux/up-device-supply.c 2014-06-07 16:48:39.391920525 +0200 @@ -821,6 +821,9 @@ supply->priv->energy_old_first = 0; } + percentage = 3.1f; + time_to_empty = 3*60; + energy = 5; g_object_set (device, "energy", energy, "energy-full", energy_full,

    Read the article

  • What is the best unit test framework for .NET and why?

    - by rmx
    It seems to me that everyone uses NUnit without even considering the other options. I think this is because: Everyone is familiar with it already so they won't have to learn a new API. It is already set up with their continuous integration server to work with NUnit. Am I wrong about this? I decided to use xUnit on one of my own projects recently and I love it! It makes so much more sense to me and conceptually it seems like a definite step forward from NUnit. I'd like to hear opinions on which framework is actually the best - not taking into consideration having to learn it or reconfigure your automated testing.

    Read the article

< Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >