Search Results

Search found 3006 results on 121 pages for 'shutdown hook'.

Page 24/121 | < Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >

  • Anything wrong with spamming GC.KeepAlive(KeyboardHookPointer)?

    - by Alex
    GC.KeepAlive() References the specified object, which makes it ineligible for garbage collection from the start of the current routine to the point where this method is called. Not really sure about what GC.KeepAlive does other than simply store a reference so the Garbage Collector doesn't collect the object. But does calling GC.KeepAlive() on an object permanently keep an object from being collected? Or do you have to re-call GC.KeepAlive() every so often (and if so, how often)? I want to keep my keyboard hook alive.

    Read the article

  • How to capture any key in X?

    - by cz-david
    Hi, I am building an application for which I need to periodically get information about users keyboard. It is going to be user idle detection application. I have a fairly simple solution to periodically check if the mouse has been moved. But I can't figure any reasonable non root way to detect if the keyboard has been pressed. I was thinking about registering a hook every timer timeout and on any key press to unregister it. So if there is no key press for a long time then my program will know if the user is idle. Anyway, I couldn't find any global hooks for any key, including modifiers. Is there an easy way to do this? Or would someone have a better way to detect keyboard idleness? Thanks, David Polák

    Read the article

  • How to exit a WPF app programmatically?

    - by j-t-s
    Hi All In the few years I've been using C# (WINFORMS), I've never used WPF. But now I love WPF, but I don't know how the hell I am supposed to exit my application when the user clicks on the Exit menu item from the File menu. Can somone please help me out!? I DID google this, and guess what? For such a Simple? thing... Nothing related came up. Thanks P.S. I have tried: this.Dispose(); this.Exit(); Application.ShutDown(); Application.Exit(); Application.Dispose(); ... Among many others. Nothing works.

    Read the article

  • How to monitor screen updates?

    - by user299600
    I am trying to write a program that monitors when the screen has been redrawn. Meaning if any part of any window is redrawn, then the program is notified. As far as I understand I should use a journal record hook like at http://www.vbaccelerator.com/home/vb/code/libraries/Hooks/Journal_Record_Hooks/article.asp However, I do not understand which MSG type would get me the WM_PAINT events (WH_CALLWNDPROC and WH_CALLWNDPROCRET do not seem to do the job). I'm not even sure that WM_PAINT is what I'm looking for... Basically, if I knew when the DC associated with GetDesktopWindow() has changed then my problem would be solved. Question is: How do you monitor screen updates?

    Read the article

  • A hooked DirectX 9 program crashes on window resize, texture related.

    - by Ben
    I'm using EasyHook and SlimDX to overlay some graphics using SlimDX's Sprite and Texture classes. When I resize windows some programs fine, but others will crash - Winamp's MilkDrop 2 gives me an ambiguous memory error for example. I expect this is due to the after market Texture I created. The question is what VTable function should I hook and/or how/when do I dispose and recreate the Texture? Reset perhaps? If it isn't obvious I don't know much about DirectX.

    Read the article

  • How to return the handle of a window when we click on it, without any DLL injection?

    - by Doo Dee
    Hello! For one of my projects, I need to create a function that will return a handle to a window when the user click on it (any window displayed on screen, and anywhere inside that window). I know it is possible to use a global hook, but I think there must be a more simple way of doing that, without using any DLL injection. In fact, I could intercept the left mouse click or intercept when a window is activated. Can I use one of those 2 solutions without any DLL injection?

    Read the article

  • Is it ok to Swallow SocketExceptions in some situations? (C#)

    - by NoPyGod
    Let's say I've programmed an application which connects to a server using the Socket Class (TCP). If I encounter a SocketException while reading or writing, then obviously I have to do go ahead and run a disconnection routine to change the application's state to Disconnected. But what if I've started to Disconnect, and while I'm cleaning up, a SocketException occurs? The SocketException doesn't really mean anything to me, as I was going to shutdown the socket myself anyway.. so is it ok to swallow it? I really want to know what the best practice for this situation is.

    Read the article

  • How to "unbind" a socket programmatically?

    - by ryan1894
    1) The socket doesn't seem to unbind from the LocalEndPoint until the process ends. 2) I have tried the solutions from the other question, and also tried waiting a minute - to no avail. 3) At the moment I have tried the below to get rid of the socket and its connections: public static void killUser(User victim) { LingerOption lo = new LingerOption(false, 0); victim.connectedSocket.SetSocketOption(SocketOptionLevel.Socket,SocketOptionName.Linger, lo); victim.connectedSocket.Shutdown(SocketShutdown.Both); victim.connectedSocket.Disconnect(true); victim.connectedSocket.Close(); clients.RemoveAt(victim.ID); } 4) After a bit of googling, I can't seem to be able to unbind a port, thus if I have a sufficient amount of connecting clients, I will eventually run out of ports to listen on.

    Read the article

  • OnShutdown() not working on XP

    - by Daro
    I have a service registered for shutdown events (.Net 3.5): public ServiceName() { InitializeComponent(); base.CanHandleSessionChangeEvent = true; base.CanHandlePowerEvent = true; base.CanShutdown = true; } protected override void OnShutdown() { try { if (Program.Debug2Eventlog == true) { WriteEventEntry( "Computer is shutting down.", EventLogEntryType.Information, 0, 3); } } catch {} base.OnShutdown(); } Windows 7 logs the event just fine, but XP doesn't. Am I missing something?

    Read the article

  • Add a Sleep Timer to Windows 7 Media Center

    - by DigitalGeekery
    Do you make it a habit of falling asleep at night while watching Windows Media Center? Today we are going to take a look at the MC7 Sleep Timer for Windows 7 Media Center. This simple little plugin allows you to schedule an automatic shutdown time in Media Center. Note: At this point MC7 Sleep Timer doesn’t work with extenders. If you’re using ClamAV or Panda it may detect this plugin as a virus, we’ve tested it and this is a false positive for these two antivirus apps. Installation and Usage Download and install MC7 Sleep Timer. (See download below) After the installation is finished, you will find MC7 Sleep Timer located in the Media Center Extras Library. Click on the tile to open the timer and configure your settings. The MC7 Sleep Timer will open in full screen mode. You can choose to shutdown the PC after 30 or 60 minutes, create a custom length shutdown timer at any 5 minute interval, or select the exact time you want the PC to shutdown.  After setting your PC to shutdown, you’ll get an audio confirmation. To set a custom timer length, scroll to the “Custom timer” option and click right or left on your Media Center remote or, the right or left arrow keys, to choose how many minutes before shutdown. To schedule a shutdown for a certain time, browse to the “Shutdown at time” button, and scroll right or left with the arrow keys on the keyboard or remote. When you’ve chosen your time, hit “Enter” on the keyboard or “OK” on the remote.   Clicking the “Monitor Off” button will turn off only the monitor and “Cancel Timer” will cancel your shutdown request. Conclusion If you often find yourself falling asleep every night watching Media Center and then fumbling and stumbling in the middle of the night to shutdown your computer, MC7 Sleep timer might just be a perfect addition to your Media Center setup. Download MC7 Sleep Timer Similar Articles Productive Geek Tips Using Netflix Watchnow in Windows Vista Media Center (Gmedia)Re-Enable Sleep Mode in Windows VistaSchedule Updates for Windows Media CenterIntegrate Hulu Desktop and Windows Media Center in Windows 7Add Color Coding to Windows 7 Media Center Program Guide TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional Use My TextTools to Edit and Organize Text Discovery Channel LIFE Theme (Win7) Increase the size of Taskbar Previews (Win 7) Scan your PC for nasties with Panda ActiveScan CleanMem – Memory Cleaner AceStock – The Personal Stock Monitor

    Read the article

  • Hooking into comment_text() to add surrounding tag

    - by Stefan Glase
    Trying to hook into the function comment_text() supplied by Wordpress API to wrap the output of every comment into a <div>...</div> container I am running into the following problem: Without my added filter the output of comment_text() looks like this: <p>Hello User!</p> <p>Thank you for your comment.</p> <p>Stefan</p> Thats fine but as I said I would like to have it wrapped into a <div class="comment-text">...</div>. As far as I know the correct way doing this would be in adding a filter to functions.php of my theme and so I did: function stefan_wrap_comment_text($content) { return "<div class=\"comment-text\">". $content ."</div>"; } add_filter('comment_text', 'stefan_wrap_comment_text'); As I can see from the output the given filter works but it has a negative sideeffect to the first paragraph of the content as you can see in the following example. The first paragraph should be <p>Hello User!</p> but looks like this: Hello User!. <div class="comment-text"> Hello User! <p>Thank you for your comment.</p> <p>Stefan</p> </div> Any ideas or hints what I am doing wrong?

    Read the article

  • C# How to find if an event is hooked up

    - by Nick
    I want to be able to find out if an event is hooked up or not. I've looked around, but I've only found solutions that involved modifying the internals of the object that contains the event. I don't want to do this. Here is some test code that I thought would work: // Create a new event handler that takes in the function I want to execute when the event fires EventHandler myEventHandler = new EventHandler(myObject_SomeEvent); // Get "p1" number events that got hooked up to myEventHandler int p1 = myEventHandler.GetInvocationList().Length; // Now actually hook an event up myObject.SomeEvent += m_myEventHandler; // Re check "p2" number of events hooked up to myEventHandler int p2 = myEventHandler.GetInvocationList().Length; Unfort the above is dead wrong. I thought that somehow the "invocationList" in myEventHandler would automatically get updated when I hooked an event to it. But no, this is not the case. The length of this always comes back as one. Is there anyway to determine this from outside the object that contains the event?

    Read the article

  • Finding a 3rd party QWidget with injected code & QWidget::find(hwnd)

    - by David Menard
    Hey, I have a Qt Dll wich I inject into a third-party Application using windows detours library: if(!DetourCreateProcessWithDll( Path, NULL, NULL, NULL, TRUE, CREATE_DEFAULT_ERROR_MODE | CREATE_SUSPENDED, NULL, NULL, &si, &pi, "C:\\Program Files\\Microsoft Research\\Detours Express 2.1\\bin\\detoured.dll", "C:\\Users\\Dave\\Documents\\Visual Studio 2008\\Projects\\XOR\\Debug\\XOR.dll", NULL)) and then I set a system-wide hook to intercept window creation: HHOOK h_hook = ::SetWindowsHookEx(WH_CBT, (HOOKPROC)CBTProc, Status::getInstance()->getXORInstance(), 0); Where XOR is my programs name, and Status::getInstance() is a Singleton where I keep globals. In my CBTProc callback, I want to intercept all windows that are QWidgets: HWND hwnd= FindWindow(L"QWidget", NULL); which works well, since I get a corresponding HWND (I checked with Spy++) Then, I want to get a pointer to the QWidget, so I can use its functions: QWidget* q = QWidget::find(hwnd); but here's the problem, the returned pointer is always 0. Am I not injecting my code into the process properly? Or am I not using QWidget::find() as I should? Thanks, Dave EDIT:If i change the QWidget::find() function to an exported function of my DLL, after setting the hooks (so I can set and catch a breakpoint), QWidgetPrivate::mapper is NULL.

    Read the article

  • How to redirect registry access of a dll loaded by my program

    - by dummzeuch
    I have got a dll that I load in my program which reads and writes its settings to the registry (hkcu). My program changes these settings prior to loading the dll so it uses the settings my program wants it to use which works fine. Unfortunately I need to run several instances of my program with different settings for the dll. Now the approach I have used so far no longer works reliably because it is possible for one instance of the program to overwrite the settings that another instance just wrote before the dll has a chance to read them. I haven't got the source of the dll in question and I cannot ask the programmer who wrote it to change it. One idea I had, was to hook registry access functions and redirect them to a different branch of the registry which is specific to the instance of my program (e.g. use the process id as part of the path). I think this should work but maybe you have got a different / more elegant. In case it matters: I am using Delphi 2007 for my program, the dll is probably written in C or C++.

    Read the article

  • Low-level Keyboard Hooks/SendInput with Winkey+L possible? (workstation lockout is intercepted in Vi

    - by Brian Jorgensen
    I work on a project called UAWKS (Unofficial Apple Wireless Keyboard Support) that helps Windows users use Apple's bluetooth keyboard. One of the main goals of UAWKS is to swap the Cmd key (which behaves as Winkey in Windows) with Ctrl, allowing users to do Cmd+C for copy, Cmd+T for new tab, etc. It is currently developed using AutoHotkey, which worked pretty well under Windows XP. However, on Vista and Windows 7, Cmd+L causes problems: Regardless of low-level keyboard hooks, Winkey+L is always intercepted by Windows and normally locks the workstation... You can disable workstation locking with this registry hack, but pressing Winkey+L still can't be rebound in AHK Pressing Winkey+L leaves Winkey in the Keydown state until the next (additional) Winkey Up. Simulating a Keyup event doesn't seem to work either! It seems that Winkey+L is a special chord that messes everything else up. I've looked through the AHK source code, and they try to address this problem in SendKey() in keyboard_mouse.cpp (near line 883 in v1.0.48.05), but it doesn't work. I wrote up my own low-level keyboard hook application in C#, and I see the same problem. Has anyone else run into this? Is there a workaround?

    Read the article

  • emacs: Can I set compilation-error-regexp-alist in a mode hook fn?

    - by Cheeso
    I am trying to set the compilation-error-regexp-alist in a function that I add as a mode hook. (defun cheeso-javascript-mode-fn () (turn-on-font-lock) ...bunch of other stuff ;; for JSLINT (make-local-variable 'compilation-error-regexp-alist) (setq compilation-error-regexp-alist '( ("^[ \t]*\\([A-Za-z.0-9_: \\-]+\\)(\\([0-9]+\\)[,]\\( *[0-9]+\\))\\( Microsoft JScript runtime error\\| JSLINT\\): \\(.+\\)$" 1 2 3) )) ;;(make-local-variable 'compile-command) (setq compile-command (let ((file (file-name-nondirectory buffer-file-name))) (concat "%windir%\\system32\\cscript.exe \\cheeso\\bin\\jslint.js " file))) ) (add-hook 'javascript-mode-hook 'cheeso-javascript-mode-fn) The mode hook runs. The various things I Set in the mode hook work. The compile-command gets set. But for some reason, the compilation-error-regexp-alist value doesn't take effect. If I later do a M-x describe-variable on compilation-error-regexp-alist, it shows me the value I think it should have. But .. the errors in the compilation buffer don't get highlighted, and M-x next-error does not work. If I add the error regexp value to the compilation-error-regexp-alist via setq-default, like this: (setq-default compilation-error-regexp-alist '( ... jslint regexp here ... ... many other regexp's here... )) ...then it works. The errors in the compilation buffer get properly highlighted and M-x next-error functions as expected.

    Read the article

  • Grub menu will not show the first time I try to boot my ubuntu server 12.04 after it is shutdown for a long time

    - by user211477
    I am running into a booting issue after installing Ubuntu Server 12.04 LTS. Following is the symptom of the problem. SYSTEM DESCRIPTION: Dual core AMD Athlon 64 3 Disks: two SATA (out of which one is SSD) and one PATA. Using LVM for disk partition management. /boot is not under LVM rest of the partitions are. / is on the SSD BIOS boot sequence is correct and points to the disk with /boot and boot loader is installed on this disk. SYMPTOMS: POST messages Blinking cursor on first line then moves to second line Screen flickers then becomes black Everything is unresponsive, hard reboot POST messages will not show up on screen. Monitor displays powersave message Force shutdown machine again. Shutoff power to machine for a few minutes. Restart machine. POST message show up. Grub menu shows up Ubuntu server 12.04 boots normally. From now on Ubuntu server boots normally until machine is shutdown for a long time (for example, 30 mins) Repeat steps 1 through 13 once the machine is started after a long time. WHAT DID I TRY? I read several posts and have tried: radeon.modeset=0 setting the gfxmode edd=0 nolacpi boot-repair Nothing seems to work. In my search I did see only one post with this same symptom. Unfortunately, I am not being able to locate that post anymore. The interesting fact is that with this same machine configuration, if I install Ubuntu Desktop 12.04 then everything works fine. Any help will be appreciated.

    Read the article

  • Is there any way to detect when nginx has completed a graceful shutdown?

    - by Daniel Vandersluis
    I have a ruby on rails application which is running on passenger and nginx, with one main webserver and multiple application servers. I am trying to update my deployment process in order to minimize (or ideally, remove) any downtime caused by the deployment. The main roadblock right now is that passenger takes some time to restart (ie. reload the application), so in order to get around this, I want to stagger my restarts so that only one app server gets restart at a time. In order to do this without losing any long running passenger processes, I am thinking I need to gracefully shutdown the app server's nginx instance, which will cause it to no longer accept new connections but continue to process the existing ones; as well, HAProxy will detect that the app server is down and route new requests to the other server. However, assuming that there is a long-running process, I am not sure how to detect when the graceful shutdown has completed so that I can start it back up. Since the shutdown is caused by sending a signal (ie. kill -QUIT $( cat /var/run/nginx.pid )), and the kill command will return immediately, I cannot combine commands (ie. kill ... && touch restarted), as the touch command will execute immediately, even if nginx hasn't completed its shutdown. Is there any good way to do this?

    Read the article

  • Windows7: Howto force a "do you really want to shutdown?" dialog

    - by Vokuhila-Oliba
    Sometimes I wanted to choose "logout current user", but then I hit "Shutdown" by accident. Nearly everywhere else Windows7 is asking "do you really want to do this Yes/No". But that's not the case when I hit the "Shutdown" button. Windows7 shuts down immediately without giving me the chance to correct my mistake. Q1: So I am wondering why Windows7 shuts down immediately without asking "really do that?" in this case. Q2: Is there a way to change this behavior? E.g. Could I force Windows7 to display a dialog asking "Do you really want to shutdown ?". ADDED: I am running Windows7 Professional 64bit. ADDED: I tried to change this behavior with the policy editor. It seems to be very easy to completely remove the Shutdown button from the start menu. But I couldn't find an entry to turn on such a Yes/No dialog.

    Read the article

  • C#/.NET Little Wonders: The Timeout static class

    - by James Michael Hare
    Once again, in this series of posts I look at the parts of the .NET Framework that may seem trivial, but can help improve your code by making it easier to write and maintain. The index of all my past little wonders posts can be found here. When I started the “Little Wonders” series, I really wanted to pay homage to parts of the .NET Framework that are often small but can help in big ways.  The item I have to discuss today really is a very small item in the .NET BCL, but once again I feel it can help make the intention of code much clearer and thus is worthy of note. The Problem - Magic numbers aren’t very readable or maintainable In my first Little Wonders Post (Five Little Wonders That Make Code Better) I mention the TimeSpan factory methods which, I feel, really help the readability of constructed TimeSpan instances. Just to quickly recap that discussion, ask yourself what the TimeSpan specified in each case below is 1: // Five minutes? Five Seconds? 2: var fiveWhat1 = new TimeSpan(0, 0, 5); 3: var fiveWhat2 = new TimeSpan(0, 0, 5, 0); 4: var fiveWhat3 = new TimeSpan(0, 0, 5, 0, 0); You’d think they’d all be the same unit of time, right?  After all, most overloads tend to tack additional arguments on the end.  But this is not the case with TimeSpan, where the constructor forms are:     TimeSpan(int hours, int minutes, int seconds);     TimeSpan(int days, int hours, int minutes, int seconds);     TimeSpan(int days, int hours, int minutes, int seconds, int milliseconds); Notice how in the 4 and 5 parameter version we suddenly have the parameter days slipping in front of hours?  This can make reading constructors like those above much harder.  Fortunately, there are TimeSpan factory methods to help make your intention crystal clear: 1: // Ah! Much clearer! 2: var fiveSeconds = TimeSpan.FromSeconds(5); These are great because they remove all ambiguity from the reader!  So in short, magic numbers in constructors and methods can be ambiguous, and anything we can do to clean up the intention of the developer will make the code much easier to read and maintain. Timeout – Readable identifiers for infinite timeout values In a similar way to TimeSpan, let’s consider specifying timeouts for some of .NET’s (or our own) many methods that allow you to specify timeout periods. For example, in the TPL Task class, there is a family of Wait() methods that can take TimeSpan or int for timeouts.  Typically, if you want to specify an infinite timeout, you’d just call the version that doesn’t take a timeout parameter at all: 1: myTask.Wait(); // infinite wait But there are versions that take the int or TimeSpan for timeout as well: 1: // Wait for 100 ms 2: myTask.Wait(100); 3:  4: // Wait for 5 seconds 5: myTask.Wait(TimeSpan.FromSeconds(5); Now, if we want to specify an infinite timeout to wait on the Task, we could pass –1 (or a TimeSpan set to –1 ms), which what the .NET BCL methods with timeouts use to represent an infinite timeout: 1: // Also infinite timeouts, but harder to read/maintain 2: myTask.Wait(-1); 3: myTask.Wait(TimeSpan.FromMilliseconds(-1)); However, these are not as readable or maintainable.  If you were writing this code, you might make the mistake of thinking 0 or int.MaxValue was an infinite timeout, and you’d be incorrect.  Also, reading the code above it isn’t as clear that –1 is infinite unless you happen to know that is the specified behavior. To make the code like this easier to read and maintain, there is a static class called Timeout in the System.Threading namespace which contains definition for infinite timeouts specified as both int and TimeSpan forms: Timeout.Infinite An integer constant with a value of –1 Timeout.InfiniteTimeSpan A static readonly TimeSpan which represents –1 ms (only available in .NET 4.5+) This makes our calls to Task.Wait() (or any other calls with timeouts) much more clear: 1: // intention to wait indefinitely is quite clear now 2: myTask.Wait(Timeout.Infinite); 3: myTask.Wait(Timeout.InfiniteTimeSpan); But wait, you may say, why would we care at all?  Why not use the version of Wait() that takes no arguments?  Good question!  When you’re directly calling the method with an infinite timeout that’s what you’d most likely do, but what if you are just passing along a timeout specified by a caller from higher up?  Or perhaps storing a timeout value from a configuration file, and want to default it to infinite? For example, perhaps you are designing a communications module and want to be able to shutdown gracefully, but if you can’t gracefully finish in a specified amount of time you want to force the connection closed.  You could create a Shutdown() method in your class, and take a TimeSpan or an int for the amount of time to wait for a clean shutdown – perhaps waiting for client to acknowledge – before terminating the connection.  So, assume we had a pub/sub system with a class to broadcast messages: 1: // Some class to broadcast messages to connected clients 2: public class Broadcaster 3: { 4: // ... 5:  6: // Shutdown connection to clients, wait for ack back from clients 7: // until all acks received or timeout, whichever happens first 8: public void Shutdown(int timeout) 9: { 10: // Kick off a task here to send shutdown request to clients and wait 11: // for the task to finish below for the specified time... 12:  13: if (!shutdownTask.Wait(timeout)) 14: { 15: // If Wait() returns false, we timed out and task 16: // did not join in time. 17: } 18: } 19: } We could even add an overload to allow us to use TimeSpan instead of int, to give our callers the flexibility to specify timeouts either way: 1: // overload to allow them to specify Timeout in TimeSpan, would 2: // just call the int version passing in the TotalMilliseconds... 3: public void Shutdown(TimeSpan timeout) 4: { 5: Shutdown(timeout.TotalMilliseconds); 6: } Notice in case of this class, we don’t assume the caller wants infinite timeouts, we choose to rely on them to tell us how long to wait.  So now, if they choose an infinite timeout, they could use the –1, which is more cryptic, or use Timeout class to make the intention clear: 1: // shutdown the broadcaster, waiting until all clients ack back 2: // without timing out. 3: myBroadcaster.Shutdown(Timeout.Infinite); We could even add a default argument using the int parameter version so that specifying no arguments to Shutdown() assumes an infinite timeout: 1: // Modified original Shutdown() method to add a default of 2: // Timeout.Infinite, works because Timeout.Infinite is a compile 3: // time constant. 4: public void Shutdown(int timeout = Timeout.Infinite) 5: { 6: // same code as before 7: } Note that you can’t default the ShutDown(TimeSpan) overload with Timeout.InfiniteTimeSpan since it is not a compile-time constant.  The only acceptable default for a TimeSpan parameter would be default(TimeSpan) which is zero milliseconds, which specified no wait, not infinite wait. Summary While Timeout.Infinite and Timeout.InfiniteTimeSpan are not earth-shattering classes in terms of functionality, they do give you very handy and readable constant values that you can use in your programs to help increase readability and maintainability when specifying infinite timeouts for various timeouts in the BCL and your own applications. Technorati Tags: C#,CSharp,.NET,Little Wonders,Timeout,Task

    Read the article

  • How to wipe RAM on shutdown (prevent Cold Boot Attacks)?

    - by proper
    My system is encrypted using Full Disk Encryption, i.e. everything except /boot is encrypted using dmcrypt/luks. I am concerned about Cold Boot Attacks. Prior work: https://tails.boum.org/contribute/design/memory_erasure/ http://tails.boum.org/forum/Ram_Wipe_Script/ http://dee.su/liberte-security http://forum.dee.su/topic/stand-alone-implementation-of-your-ram-wipe-scripts Can you please provide instructions on how to wipe the RAM once Ubuntu is shutdown/restarted? Thanks for your efforts!

    Read the article

  • Add comment to subversion commit automatically

    - by Paul Alexander
    I've already got my subversion repository set up to require comments of a minimum length to accept a commit. However, I'd like to start tagging those comments with information from our bug tracking system when committed. I've already got the scripts set up to pull data from the bug tracker and just need a way to get that info into the subversion commit comments. How can append to the existing comment in subversion automatically? For reference, the subversion repository is hosted on a linux server with Ubuntu 9 something installed and I have complete root access to the machine.

    Read the article

  • What does WIX's CloseApplication functionality do and how would can the application respond to such

    - by tronda
    In the WIX setup I've got, when upgrading the application I have set a requirement to close down applications which might hold on to files which needs to be updated: <util:CloseApplication Id="CloseMyApp" Target="[MyAppExe]" CloseMessage="no" Description="!(loc.MyAppStillRunning)" RebootPrompt="no" ElevatedCloseMessage="no" /> The application on the other hand will capture closing down the window with a "user friendly" dialog box where the user can confirm that he or she wants to close down the application. I've experienced problems with the CloseApplication, and one theory is that the dialog box stops the application from closing. So the question is: Could this be a possible problem? If so - how can I have this confirmation dialog box and still behave properly when the installer asks the application to close down? Must I listen to Win32 messages (such as WM_QUIT/WM_CLOSE) or is there a .NET API which I can use to respond properly to these events?

    Read the article

  • How can I do something ~after~ an event has fired in C#?

    - by Siracuse
    I'm using the following project to handle global keyboard and mouse hooking in my C# application. This project is basically a wrapper around the Win API call SetWindowsHookEx using either the WH_MOUSE_LL or WH_KEYBOARD_LL constants. It also manages certain state and generally makes this kind of hooking pretty pain free. I'm using this for a mouse gesture recognition software I'm working on. Basically, I have it setup so it detects when a global hotkey is pressed down (say CTRL), then the user moves the mouse in the shape of a pre-defined gesture and then releases global hotkey. The event for the KeyDown is processed and tells my program to start recording the mouse locations until it receives the KeyUp event. This is working fine and it allows an easy way for users to enter a mouse-gesture mode. Once the KeyUp event fires and it detects the appropriate gesture, it is suppose to send certain keystrokes to the active window that the user has defined for that particular gesture they just drew. I'm using the SendKeys.Send/SendWait methods to send output to the current window. My problem is this: When the user releases their global hotkey (say CTRL), it fires the KeyUp event. My program takes its recorded mouse points and detects the relevant gesture and attempts to send the correct input via SendKeys. However, because all of this is in the KeyUp event, that global hotkey hasn't finished being processed. So, for example if I defined a gesture to send the key "A" when it is detected, and my global hotkey is CTRL, when it is detected SendKeys will send "A" but while CTRL is still "down". So, instead of just sending A, I'm getting CTRL-A. So, in this example, instead of physically sending the single character "A" it is selecting-all via the CTRL-A shortcut. Even though the user has released the CTRL (global hotkey), it is still being considered down by the system. Once my KeyUp event fires, how can I have my program wait some period of time or for some event so I can be sure that the global hotkey is truly no longer being registered by the system, and only then sending the correct input via SendKeys?

    Read the article

< Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >