Search Results

Search found 23614 results on 945 pages for 'update'.

Page 24/945 | < Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >

  • why does InnoDB keep on growing without for every update?

    - by Akash Kava
    I have a table which consists of heavy blobs, and I wanted to conduct some tests on it. I know deleted space is not reclaimed by innodb, so I decided to reuse existing records by updating its own values instead of createing new records. But I noticed, whether I delete and insert a new entry, or I do UPDATE on existing ROW, InnoDB keeps on growing. Assuming I have 100 Rows, each Storing 500KB of information, My InnoDB size is 10MB, now when I call UPDATE on all rows (no insert/ no delete), the innodb grows by ~8MB for every run I do. All I am doing is I am storing exactly 500KB of data in each row, with little modification, and size of blob is fixed. What can I do to prevent this? I know about optimize table, but I cant do it because on regular usage, the table is going to be 60-100GB big, and running optimize will just stall entire server.

    Read the article

  • MYSQL to UPDATE table if row with 2 specific columns exist or INSERT new row if it does not exist

    - by user2509541
    I have a MYSQL table that looks as follows: id id_jugador id_partido team1 team2 1 2 1 5 2 2 2 2 1 1 3 1 2 0 0 I need to create a query to either INSERT new rows in the table or UPDATE the table. The condition is based on id_jugador and id_partido, meaning that if I wanted to insert id_jugador = 2 and id_partido = 1, then it should just UPDATE the existing row with the new team1 and team2 values I am sending. And dont duplicate the row. However, if I have an entry id_jugador=2 and id_partido=3, since this combination does not exist yet, it should add the new row. I read about the REPLACE INTO but it seems to be unable to check combination of UNIQUE KEYS.

    Read the article

  • Would it be possible for web browsers to automatically update rendering engines?

    - by unknowing
    As a way to prevent the major annoyances of browser segmentation and older versions. This way the code would only need to be done for the latest version of the browser, but users could still have the functionality of the older version and not be forced to do major updates? I am sure there will be some major flaws in this, and I would like you to tell me what they are! -Obviously, people may not want this as often auto-updating is frowned upon, however Chrome does it (or at least, they used to); Without a manual check, Chrome will update itself automatically, Google said. "Google Chrome will automatically checks for updates approximately every five hours. If an update is available, it will be downloaded and applied at the next browser restart," Google said. -there is still the problem of getting users from the really old ones onto the any new browsers that have this functionality -To prevent exploits in terms of updates, maybe they could have a 7 day opt-in period before being pushed out to everyone?

    Read the article

  • Correcting an UPDATE statement (and making it more secure!)

    - by Jess
    I'm trying to a single value in my DB...When I run it through the console, it works correctly (as I'm replacing the variables with numbers and text).. However, My query is not running correctly. It's just prompting a syntax error Here is what I have: "UPDATE books SET readstatus='".$readstatus."' WHERE book_id=".$book_id; This won't work, I also tried doing something like this as I'm told this makes it a bit more secure? : "UPDATE books SET readstatus='{$readstatus}', WHERE read_id='{read_id}'"; This does not prompt any errors, but no change is happeneing to the value in the DB, I'm guessing the syntax is incorrect.

    Read the article

  • Problems with updates

    - by legospace9876
    I can not update Weather Indicator with Update Manager. This is the terminal log: installArchives() failed: perl: warning: Setting locale failed. perl: warning: Please check that your locale settings: LANGUAGE = (unset), LC_ALL = (unset), LANG = "sr_RS.utf_8_latin" are supported and installed on your system. perl: warning: Falling back to the standard locale ("C"). locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory perl: warning: Setting locale failed. perl: warning: Please check that your locale settings: LANGUAGE = (unset), LC_ALL = (unset), LANG = "sr_RS.utf_8_latin" are supported and installed on your system. perl: warning: Falling back to the standard locale ("C"). locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory perl: warning: Setting locale failed. perl: warning: Please check that your locale settings: LANGUAGE = (unset), LC_ALL = (unset), LANG = "sr_RS.utf_8_latin" are supported and installed on your system. perl: warning: Falling back to the standard locale ("C"). locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory perl: warning: Setting locale failed. perl: warning: Please check that your locale settings: LANGUAGE = (unset), LC_ALL = (unset), LANG = "sr_RS.utf_8_latin" are supported and installed on your system. perl: warning: Falling back to the andard locale ("C"). locale: Cannot set LC_CTYPE to default locale: No such file or directory locale: Cannot set LC_MESSAGES to default locale: No such file or directory locale: Cannot set LC_ALL to default locale: No such file or directory Setting up indicator-weather (11.11.28-0ubuntu1.1) ... Installing indicator-specific icons... Installing indicator dconf schema... cp: cannot stat `/usr/share/indicator-weather/indicator-weather.gschema.xml': No such file or directory dpkg: error processing indicator-weather (--configure): subprocess installed post-installation script returned error exit status 1 Errors were encountered while processing: indicator-weather Error in function: SystemError: E:Sub-process /usr/bin/dpkg returned an error code (1) Setting up indicator-weather (11.11.28-0ubuntu1.1) ... Installing indicator-specific icons... Installing indicator dconf schema... cp: cannot stat `**/usr/share/indicator-weather/indicator-weather.gschema.xml**': No such file or directory dpkg: error processing indicator-weather (--configure): subprocess installed post-installation script returned error exit status 1 The file that I bold really does not exist. How can I solve this problem?

    Read the article

  • How to resolve the "Failed to download repository" error?

    - by jojo
    I've tried to update but then I got this error Here's the error information in that box: W:GPG error: http://extras.ubuntu.com precise Release: The following signatures were invalid: BADSIG 16126D3A3E5C1192 Ubuntu Extras Archive Automatic Signing Key <[email protected]>, W:Failed to fetch http://ppa.launchpad.net/unity-team/hud/ubuntu/dists/precise/main/source/Sources 404 Not Found, W:Failed to fetch http://ppa.launchpad.net/unity-team/hud/ubuntu/dists/precise/main/binary-i386/Packages 404 Not Found, E:Some index files failed to download. They have been ignored, or old ones used instead. And my Internet connection is working fine. After trying $ sudo apt-get install ppa-purge Reading package lists... Done Building dependency tree Reading state information... Done ppa-purge is already the newest version. The following packages were automatically installed and are no longer required: language-pack-zh-hans language-pack-kde-en language-pack-kde-zh-hans language-pack-kde-en-base kde-l10n-engb kde-l10n-zhcn language-pack-zh-hans-base firefox-locale-zh-hans language-pack-kde-zh-hans-base Use 'apt-get autoremove' to remove them. 0 upgraded, 0 newly installed, 0 to remove and 0 not upgraded. $ sudo ppa-purge ppa:unity-team/hud Updating packages lists W: GPG error: http://extras.ubuntu.com precise Release: The following signatures were invalid: BADSIG 16126D3A3E5C1192 Ubuntu Extras Archive Automatic Signing Key <[email protected]> W: Failed to fetch http://ppa.launchpad.net/unity-team/hud/ubuntu/dists/precise/main/source/Sources 404 Not Found W: Failed to fetch http://ppa.launchpad.net/unity-team/hud/ubuntu/dists/precise/main/binary-i386/Packages 404 Not Found E: Some index files failed to download. They have been ignored, or old ones used instead. Warning: apt-get update failed for some reason PPA to be removed: unity-team hud Warning: Could not find package list for PPA: unity-team hud I've tried $ sudo apt-key adv --recv-keys --keyserver keyserver.ubuntu.com 16126D3A3E5C1192 Executing: gpg --ignore-time-conflict --no-options --no-default-keyring --secret-keyring /tmp/tmp.v6Ucus0B10 --trustdb-name /etc/apt/trustdb.gpg --keyring /etc/apt/trusted.gpg --primary-keyring /etc/apt/trusted.gpg --recv-keys --keyserver keyserver.ubuntu.com 16126D3A3E5C1192 gpg: requesting key 3E5C1192 from hkp server keyserver.ubuntu.com gpg: key 3E5C1192: "Ubuntu Extras Archive Automatic Signing Key <[email protected]>" not changed gpg: Total number processed: 1 gpg: unchanged: 1 And then started the same procedure but of no use.

    Read the article

  • 10.10 irritating updater message

    - by Ashu
    As you all know 10.10 support has ended. thus whenever i start the update manager i get a dialog box saying Your Ubuntu release is not supported anymore You will not get any further security fixes or critical updates. Please upgrade to a later version of Ubuntu Linux. any way to remove this? that is really bugging me. ps. updating to a newer version is not an option now the screenshot

    Read the article

  • Install build-essentials in ubuntu 12.04

    - by Mukul Shukla
    After I install a fresh copy of ubuntu and I need to install build-essentials, I have to type: sudo apt-get update and sudo apt-get upgrade before installing build-essentials These two commands take a LOOTTT of time and install many things. Is there a way to install build-essentials without running these two commands, or a way that these two commands don't install all the updates and hence will take less time.

    Read the article

  • how to update child records when updating the Master table using Linq [closed]

    - by user20358
    I currently use a general repositry class that can update only a single table like so public abstract class MyRepository<T> : IRepository<T> where T : class { protected IObjectSet<T> _objectSet; protected ObjectContext _context; public MyRepository(ObjectContext Context) { _objectSet = Context.CreateObjectSet<T>(); _context = Context; } public IQueryable<T> GetAll() { return _objectSet.AsQueryable(); } public IQueryable<T> Find(Expression<Func<T, bool>> filter) { return _objectSet.Where(filter); } public void Add(T entity) { _objectSet.AddObject(entity); _context.ObjectStateManager.ChangeObjectState(entity, System.Data.EntityState.Added); _context.SaveChanges(); } public void Update(T entity) { _context.ObjectStateManager.ChangeObjectState(entity, System.Data.EntityState.Modified); _context.SaveChanges(); } public void Delete(T entity) { _objectSet.Attach(entity); _context.ObjectStateManager.ChangeObjectState(entity, System.Data.EntityState.Deleted); _objectSet.DeleteObject(entity); _context.SaveChanges(); } } For every table class generated by my EDMX designer I create another class like this public class CustomerRepo : MyRepository<Customer> { public CustomerRepo (ObjectContext context) : base(context) { } } for any updates that I need to make to a particular table I do this: Customer CustomerObj = new Customer(); CustomerObj.Prop1 = ... CustomerObj.Prop2 = ... CustomerObj.Prop3 = ... CustomerRepo.Update(CustomerObj); This works perfectly well when I am updating just to the specific table called Customer. Now if I need to also update each row of another table which is a child of Customer called Orders what changes do I need to make to the class MyRepository. Orders table will have multiple records for a Customer record and multiple fields too, say for example Field1, Field2, Field3. So my questions are: 1.) If I only need to update Field1 of the Orders table for some rows based on a condition and Field2 for some other rows based on a different condition then what changes I need to do? 2.) If there is no such condition and all child rows need to be updated with the same value for all rows then what changes do I need to do? Thanks for taking the time. Look forward to your inputs...

    Read the article

  • Insert Or update (aka Replace or Upsert)

    - by Davide Mauri
    The topic is really not new but since it’s the second time in few days that I had to explain it different customers, I think it’s worth to make a post out of it. Many times developers would like to insert a new row in a table or, if the row already exists, update it with new data. MySQL has a specific statement for this action, called REPLACE: http://dev.mysql.com/doc/refman/5.0/en/replace.html or the INSERT …. ON DUPLICATE KEY UPDATE option: http://dev.mysql.com/doc/refman/5.0/en/insert-on-duplicate.html With SQL Server you can do the very same using a more standard way, using the MERGE statement, with the support of Row Constructors. Let’s say that you have this table: CREATE TABLE dbo.MyTargetTable (     id INT NOT NULL PRIMARY KEY IDENTITY,     alternate_key VARCHAR(50) UNIQUE,     col_1 INT,     col_2 INT,     col_3 INT,     col_4 INT,     col_5 INT ) GO INSERT [dbo].[MyTargetTable] VALUES ('GUQNH', 10, 100, 1000, 10000, 100000), ('UJAHL', 20, 200, 2000, 20000, 200000), ('YKXVW', 30, 300, 3000, 30000, 300000), ('SXMOJ', 40, 400, 4000, 40000, 400000), ('JTPGM', 50, 500, 5000, 50000, 500000), ('ZITKS', 60, 600, 6000, 60000, 600000), ('GGEYD', 70, 700, 7000, 70000, 700000), ('UFXMS', 80, 800, 8000, 80000, 800000), ('BNGGP', 90, 900, 9000, 90000, 900000), ('AMUKO', 100, 1000, 10000, 100000, 1000000) GO If you want to insert or update a row, you can just do that: MERGE INTO     dbo.MyTargetTable T USING     (SELECT * FROM (VALUES ('ZITKS', 61, 601, 6001, 60001, 600001)) Dummy(alternate_key, col_1, col_2, col_3, col_4, col_5)) S ON     T.alternate_key = S.alternate_key WHEN     NOT MATCHED THEN     INSERT VALUES (alternate_key, col_1, col_2, col_3, col_4, col_5) WHEN     MATCHED AND T.col_1 != S.col_1 THEN     UPDATE SET         T.col_1 = S.col_1,         T.col_2 = S.col_2,         T.col_3 = S.col_3,         T.col_4 = S.col_4,         T.col_5 = S.col_5 ; If you want to insert/update more than one row at once, you can super-charge the idea using Table-Value Parameters, that you can just send from your .NET application. Easy, powerful and effective

    Read the article

  • ||| New to Ubuntu + Need Help | Quantal . Dualboot . built in linux . toolbar ....

    - by nuevo Ubuntu
    i have installed Ubuntu quantal 12 along with Windows it worked fine at start and now the toolbar and most features in Ubuntu (including updates) are not working and i am only able to use a different linux interface... fire wall application is not present and i can't add any new software Upgrading option is only present at start and mostly freezes after short while of use! What can i do to restore the (normal Ubuntu) along with toolbar and to update or upgrade?

    Read the article

  • Fail to download repository information

    - by BRvitorio
    Why lately I've been getting this error when I try to update my computer? Ubuntu 12.04 Kernel 3.5.2 Processor i386 W:Failed to fetch http://ppa.launchpad.net/kernel-ppa/ppa/ubuntu/dists/precise/main/source/Sources 404 Not Found, W:Failed to fetch http://ppa.launchpad.net/kernel-ppa/ppa/ubuntu/dists/precise/main/binary-i386/Packages 404 Not Found, E:Some index files failed to download. They have been ignored, or old ones used instead.

    Read the article

  • Passing elapsed time to the update function from the game loop

    - by Sri Harsha Chilakapati
    I want to pass the time elapsed to the update() method as this would make easy to implement the animations and time related concepts. Here's my game-loop. public void gameLoop(){ boolean running = true; long gameTime = getCurrentTime(); long elapsedTime = 0; long lastUpdateTime = 0; int loops; while (running){ loops = 0; while(getCurrentTime()>gameTime && loops<Global.MAX_FRAMESKIP){ elapsedTime = getCurrentTime() - lastUpdateTime; lastUpdateTime = getCurrentTime(); update(elapsedTime); gameTime += SKIP_STEPS; loops++; } displayGame(); } } getCurrentTime() method public long getCurrentTime(){ return (System.nanoTime()/1000000); } update() method long time = 0; public void update(long elapsedTime){ time += elapsedTime; if (time>=1000){ System.out.println("A second elapsed"); time -= 1000; } } But this is printing the message for 3 seconds. Thanks.

    Read the article

  • Announcement: Oracle Database Appliance 2.4 patch update now available

    - by uwes
    The Oracle Database Appliance 2.4 patch is now available from My Oracle Support (MOS).  If you search for the Oracle Database Appliance 2.4.0.0.0 Kit under Patches it will display the newly uploaded bundles. The patch highlights include: Normal redundancy (double-mirroring) option providing 6TB of usable storage Enhanced Diagnostics - Trace File Analyzer and ODACHK Also, if you review the README, you may see content that says:        "The grid infrastructure and database patching, both are rolling upgradable. During our patching, we patch the node 1 first and when completed, we patch the node 2." I would like to clarify that the 'infrastructure' updates (OS, Firmware, ILOM, etc) will require a  short downtime of the ODA while it is applied.  When you update the grid infrastructure (--gi), the appliance manager verifies that the infrastructure was updated so you cannot just patch the GI without first updating the infrastructure. The high level update patch steps include (but not limited to): Download patch update to your ODA The --infra (infrastructure) is updated and ODA Databases are down and the ODA is/may be rebooted ODA and GI/Databases are restarted Issue the command to update the Grid Infrastructure/databases (The order of the steps are completed automatically and you cannot control when the nodes are brought up and down during the patching) Node 1 -- shutdown databases and GI Node 1 -- patch GI/database Node 1 -- bring up databases and GI Node 2 -- shutdown databases and GI Node 2 -- patch GI/database Node 2 -- bring up databases and GI A replay from Friday's with Sohan on the 2.4 release can be found here.  The PDF of the presentation is here. The Data Sheet, WP, and 2.4 Configurator are available on the ODA OTN site.

    Read the article

  • Eris Update to 2.1 &ndash; No Problems

    - by Bunch
    I updated my Eris to Android’s 2.1 OS last night and everything went pretty well. I had wanted to update the phone mainly for two reasons. The first was to have the Navigation feature of the Google Maps application and to make YouTube work again. YouTube used to work on the phone and then stopped a few weeks ago. But before I started I looked around various forums and blogs to see what doom and gloom folks were talking about the update. Based on what I read and some common sense I used the following steps: Made sure there was a good charge on the phone. Connected to our WiFi (the download is about 77 megs, not very 3G friendly). Checked that the contacts were synced with the GMail account. As a precaution I copied off any music and pictures from the SD card to my laptop. Started the update process and waited for the download and installation to complete. It took maybe 30 minutes to do everything. After the update I re-synced the contacts and tested out the phone (it does make calls after all). I did need to download the text to speech application to get the Maps Navigation to work but that was easy enough since the application prompted me to download it. And now the YouTube application works again. Technorati Tags: Android

    Read the article

  • how to get the update manager window visible?

    - by Max Waterman
    I can see from the launcher that the Update Manager is running - it has the little triangle by it. However, I am having trouble seeing the window. If I click on it from one desktop, it switches to another, so I assume that the Update Manager has its window on that other desktop, but it still doesn't show anything. If I click alt-tab to switch between apps, I can see that the Update Manager is there, but selecting it just shows me a blank screen. Also, when I select it, while still holding the alt-key, I see the top menu bar switch to 'Update Manager', but when I release alt, it changes back to Ubuntu Desktop. It's almost like the app is off the screen somewhere, perhaps with just a single pixel showing or something like that. disclaimer: One thing that might be affecting things is that I have 'focus follows mouse' configured, which makes things a bit funky with the menu not being on the window, where it should be (perhaps there's a way to put it back with the window?) - I like to be able to type into background windows, and manually control which window is in the foreground.

    Read the article

  • Optimal communication pattern to update subscribers

    - by hpc
    What is the optimal way to update the subscriber's local model on changes C on a central model M? ( M + C - M_c) The update can be done by the following methods: Publish the updated model M_c to all subscribers. Drawback: if the model is big in contrast to the change it results in much more data to be communicated. Publish change C to all subscribes. The subscribers will then update their local model in the same way as the server does. Drawback: The client needs to know the business logic to update the model in the same way as the server. It must be assured that the subscribed model stays equal to the central model. Calculate the delta (or patch) of the change (M_c - M = D_c) and transfer the delta. Drawback: This requires that calculating and applying the delta (M + D_c = M_c) is an cheap/easy operation. If a client newly subscribes it must be initialized. This involves sending the current model M. So method 1 is always required. Think of playing chess as a concrete example: Subscribers send moves and want to see the latest chess board state. The server checks validity of the move and applies it to the chess board. The server can then send the updated chessboard (method 1) or just send the move (method 2) or send the delta (method 3): remove piece on field D4, put tower on field D8.

    Read the article

  • Creating an update method in a different class

    - by Sweta Dwivedi
    I have created a class called 3D model which will animate my 3D model by changing the model position according to the values based in a .txt file through a list... Since i'm using a foreach loop to read the point values when it reaches the end of the file.. XNA throws an out of bounds exception .. (which is obvious) but if i add the same code in my Game.cs update(gameTime) method.. then i dont have this problem..Any idea how to make my 3D model update work same as the update in game.cs .. Here is the code for some idea: public void patterns(GameTime gameTime) { motion_z = new List<Point3D>(); if (pattern == 1) { f = "E:/Motion_Track-output/Output1.txt"; } if (pattern == 2) { f = "E:/Motion_Track-output/cruse.txt"; } // TODO: Add your update logic here using (StreamReader r = new StreamReader(f)) { string line; //Viewport view = graphics.GraphicsDevice.Viewport; int maxWidth = view.Width; int maxHeight = view.Height; while ((line = r.ReadLine()) != null) { string[] temp = line.Split(','); int x = (int)Math.Floor(((float.Parse(temp[0]) * 0.5f) + 0.5f) * maxWidth); int y = (int)Math.Floor(((float.Parse(temp[1]) * -0.5f) + 0.5f) * maxHeight); int z = (int)Math.Floor(((float.Parse(temp[2]) / 4 * 20000))); motion_z.Add(new Point3D(x, y, z)); } modelPosition.X = (float)(motion_z[i].X); modelPosition.Y = (float)(motion_z[i].Y); modelPosition.Z = (float)(motion_z[i].Z); i++; } //Console.WriteLine("modelposX:" + modelPosition.X + "," + "motionzX:" + motion_z[i].X); }

    Read the article

  • Input of mouseclick not always registered in XNA Update method

    - by LordrAider
    I have a problem that not all inputs of my mouse events seem to be registered. The update logic is checking a 2 dimensional array of 10x10 . It's logic for a jewel matching game. So when i switch my jewel I can't click on another jewel for like half a second. I tested it with a click counter variable and it doesn't hit the debugger when i click the second time after the jewel switch. Only if I do the second click after waiting half a second longer. Could it be that the update logic is too heavy that while he is executing update logic my click is happening and he doesn't register it? What am I not seeing here :)? Or doing wrong. It is my first game. My function of the update methode looks like this. public void UpdateBoard() { MouseState currentMouseState; currentMouseState = Mouse.GetState(); if (currentMouseState.LeftButton == ButtonState.Pressed && prevMouseState.LeftButton != ButtonState.Pressed) { UpdatingLogic = true; // this.CheckDropJewels(currentMouseState); //this.CheckMatches(3); //this.RemoveMatches(); this.CheckForSwitch(currentMouseState); this.MarkJewel(currentMouseState); UpdatingLogic = false; //reIndexMissingJewels = true; reIndexSwitchedJewels = true; } prevMouseState = currentMouseState; this.ReIndex(); this.UpdateJewels(); }

    Read the article

  • freebsd-update reports an upgraded jail as not upgraded

    - by Martin Torhage
    I've set up a "Service Jail" in FreeBSD 8.0 according to the FreeBSD Handbook (http://www.freebsd.org/doc/en_US.ISO8859-1/books/handbook/jails-application.html). After upgrading the host to the latest patch level and then performed a jail-upgrade, freebsd-fetch still reports that there are files in need of an update in the jail. Is this expected? Then how do I know if a jail is up to date? This is what I've done in more detail: After the initial setup of the jail freebsd-update fetch reported that there were no updates available neither in the host system nor in the jail. This was expected. A while later freebsd-update fetch reported that the following files where in need of an update both in the host and in the jail. /usr/lib/libssl.a /usr/lib/libssl_p.a /usr/lib/libzpool.a /usr/lib32/libssl.a /usr/lib32/libssl_p.a /usr/lib32/libzpool.a I updated the host and followed the upgrade guide for the jail (http://www.freebsd.org/doc/en_US.ISO8859-1/books/handbook/jails-application.html#JAILS-SERVICE-JAILS-UPGRADING). freebsd-update fetch now reports that there are no updates available in the host but the following is the output from freebsd-update fetch in the jail: [root@bb /]# freebsd-update fetch Looking up update.FreeBSD.org mirrors... 3 mirrors found. Fetching metadata signature for 8.0-RELEASE from update5.FreeBSD.org... done. Fetching metadata index... done. Inspecting system... done. Preparing to download files... done. The following files are affected by updates, but no changes have been downloaded because the files have been modified locally: /var/db/mergemaster.mtree The following files will be updated as part of updating to 8.0-RELEASE-p2: /usr/lib/libssl.a /usr/lib/libssl_p.a /usr/lib/libzpool.a /usr/lib32/libssl.a /usr/lib32/libssl_p.a /usr/lib32/libzpool.a Shouldn't freebsd-update know that the jail is up to date or have I failed upgrading it? How am I supposed to know if a jail is up to date if freebsd-update can't tell? I'm sure I ran make cleandir twice before make buildworld. TIA

    Read the article

  • Windows 7 + Deep Freeze - I'm stuck in an endless reboot loop

    - by myermian
    I have the following setup: Windows 7 Ultimate Deep Freeze I "thawed" my machine last night and performed a Windows Update. The update is having issues (it gets stuck at 32%, fails, and restarts my machine). When it reboots it attempts it again, and again, and again, etc. (Endless loop). I looked online and found some solutions, but none of them seem to be working: When I run Safe Mode, Safe Mode w/ Network, or Safe Mode w/ Command Prompt it attempts to revert the Windows Update changes. However, the problem is with Deep Freeze on (and now in "Frozen" mode) the reverted changes don't stay, and I'm back into the loop of death. Oh, and side note: "Safe Mode w/ Command Prompt" does not actually take me to a command prompt window? Perhaps because it is attempting to complete the Windows Update changes first? I have tried to select the option to NOT restart when an windows error occurs, but it still does. I tried the remainder of all the other options in the F8 screen. The only other option left is to find my Windows 7 Media Disc (I can't find it right now) and use it to repair windows (because for some reason the repair option does not show up in the F8 screen). Is there a way to disable Deep Freeze from loading? When I selected "Safe Mode w/ Command Prompt" I noticed that it loads the DpFrz.sys file. I know that when I'm in the Windows Boot Manager if I press F10 instead of F8 (while highlighting Windows 7) it takes me to an "Edit Boot Options" screen: Edit Windows boot options for: Windows 7 Path: \Windows\system32\winload.exe Partition: 2 Hard Disk: 8e90e329 [ /NOEXECUTE=OPTIN (I CAN EDIT THIS LINE) ] Update: I found my Windows 7 Media Disk and it did not help out. The laptop had the "System Restore" as a partition on the HDD. I later received (in the mail) a Windows 7 Upgrade Disc from Sony to upgrade my system from Windows Vista to Windows 7 Ultimate. I placed the disc into the DVD drive and it does not come up as a "bootable" disc. I'm going to try to find an alternative disc to see if I can get into Command Prompt. Update 2: I got a Windows Repair disc and got into a command prompt window. I got into the registry and disabled Deep Freeze. Also: I renamed the Pending.xml file to Pending.old I cleared out the Windows Temp directory I still am stuck in the loop (though, it isn't an issue with DeepFreeze anymore because I can make changes to the hard drive and they persist). Not sure what to do at this point? Update 3: I ran the repair option and it couldn't repair, but it did point me to something. It says the error was due to a driver that was failing. I have a feeling it is my UPEK Fingerprint scanner.

    Read the article

  • Error 80073701 when installing Windows 7 Service Pack 1

    - by Wagner Maestrelli
    I tried to install the Windows 7 Service Pack 1 using Windows Update and I got an error (code 80073701 - unknown error). I tried it again, same thing. Rebooted and tried again, same error. Before I tried to install the SP1 I had installed all the previous updates. I have Windows 7 Ultimate 32-bits. Has anyone gone through the same problem? Any ideas of what might be happening? Thanks! UPDATE: I installed the System Update Readiness Tool. Then, I tried to install the SP1 again, but the installation failed again with the same error. As I thought I was running out of options, I downloaded the SP1 package (500+ MB) and tried to install manually. Before that, I reinstalled the SUR Update. Well, the manual installation of the SP1 failed again. Then I learned about the c:\Windows\Logs\CBS\CheckSUR.log file (thanks Patches!). I checked it out. As I installed the SUR Update multiple times, the older logs are kept in the c:\Windows\Logs\CBS\CheckSUR.persist.log file. In the first time the SUR update was installed there was an error, which is said to have been fixed. In the subsequent logs, no errors were detected. The log with the error: ================================= Checking System Update Readiness. Binary Version 6.1.7600.20593 Package Version 7.0 2010-03-19 09:57 Checking Windows Servicing Packages Checking Package Manifests and Catalogs (f) CBS MUM Corrupt 0x800B0100 servicing\Packages\Microsoft-Windows-Client-LanguagePack-Package~31bf3856ad364e35~x86~pt-BR~6.1.7600.16385.mum servicing\Packages\Microsoft-Windows-Client-LanguagePack-Package~31bf3856ad364e35~x86~pt-BR~6.1.7600.16385.cat Package manifest cannot be validated by the corresponding catalog (fix) CBS MUM Corrupt CBS File Replaced Microsoft-Windows-Client-LanguagePack-Package~31bf3856ad364e35~x86~pt-BR~6.1.7600.16385.mum from Cabinet: C:\Windows\CheckSur\v1.0\windows6.1-rtm-client-cab3-x86.cab. (fix) CBS Paired File CBS File also Replaced Microsoft-Windows-Client-LanguagePack-Package~31bf3856ad364e35~x86~pt-BR~6.1.7600.16385.cat from Cabinet: C:\Windows\CheckSur\v1.0\windows6.1-rtm-client-cab3-x86.cab. Checking Package Watchlist Checking Component Watchlist Checking Packages Checking Component Store Summary: Seconds executed: 224 Found 1 errors Fixed 1 errors CBS MUM Corrupt Total count: 1 Fixed: CBS MUM Corrupt. Total count: 1 Fixed: CBS Paired File. Total count: 1 It seems it has something to do with the Brazilian Portuguese Language Pack, which happens to be my native language. Problem is I can't uninstall the language pack since it is my system default language. And I haven't found any place to download it so I could reinstall it manually. Well, any ideas? Thanks!

    Read the article

  • What is the best way to update an unattached entity on Entity Framework?

    - by Carlos Loth
    Hi, In my project I have some data classes to retrieve data from the database using the Entity Framework. We called these classes *EntityName*Manager. All of them have a method to retrieve entities from database and they behave most like this: static public EntityA SelectByName(String name) { using (var context = new ApplicationContext()) { var query = from a in context.EntityASet where a.Name == name select a; try { var entityA = query.First(); context.Detach(entityA); return entityA; } catch (InvalidOperationException ex) { throw new DataLayerException( String.Format("The entityA whose name is '{0}' was not found.", name), ex); } } } You can see that I detach the entity before return it to the method caller. So, my question is "what is the best way to create an update method on my *EntityA*Manager class?" I'd like to pass the modified entity as a parameter of the method. But I haven't figured out a way of doing it without going to the database and reload the entity and update its values inside a new context. Any ideas? Thanks in advance, Carlos Loth.

    Read the article

  • Are there solutions for streamlining the update of legacy code in multiple places?

    - by ccomet
    I'm working in some old code which was originally designed for handling two different kinds of files. I was recently tasked with adding a new kind of file to this code. Most of my problems were solved by filling out an extensive XML file with a new entry that handled everything from what lists were named to how the file is written in plural lower case. But this ended up being insufficient, as there were maybe 50 different places in 24 different code files where I had to update hardcoded switch-statements that only branched for the original two file types. Unfortunately there is no consistency in this; there are methods which operate half from the XML file, and half off of hardcode. Some of the files which look like they would operate off of the XML file don't, and some that I would expect that I'd need to update the hardcode don't need it. So the only way to find the majority of these is to run through testing the whole system when only part of it is operational, finding that one step to fix (when I'm lucky that error logging actually tells me what is going on), and then running the whole thing again. This wastes time testing the parts of the code which are already confirmed to work, time better spent testing the new parts I have to add on top of it all. It's a hassle and a half, and to my luck I can expect that I will have to add yet another new kind of file in the near future. Are there any solutions out there which can aid in this kind of endeavour? Something which I can input some parameters of current features, document what points in a whole code project actually need to be updated, and run something nice the next time I need to add a new feature to the code. It needn't even be fully automated, something that'll help me navigate straight to the specific points in everything and maybe even record what kind of parameters need to be loaded. Doubt it matters specifically, but the code is comprised of ASP.NET pages, some ASP.NET controls, hundreds of C# code files, and a handful of additional XML files. It's all currently in a couple big Visual Studio 2008 projects.

    Read the article

  • How to update GUI thread/class from worker thread/class?

    - by user315182
    First question here so hello everyone. The requirement I'm working on is a small test application that communicates with an external device over a serial port. The communication can take a long time, and the device can return all sorts of errors. The device is nicely abstracted in its own class that the GUI thread starts to run in its own thread and has the usual open/close/read data/write data basic functions. The GUI is also pretty simple - choose COM port, open, close, show data read or errors from device, allow modification and write back etc. The question is simply how to update the GUI from the device class? There are several distinct types of data the device deals with so I need a relatively generic bridge between the GUI form/thread class and the working device class/thread. In the GUI to device direction everything works fine with [Begin]Invoke calls for open/close/read/write etc. on various GUI generated events. I've read the thread here (How to update GUI from another thread in C#?) where the assumption is made that the GUI and worker thread are in the same class. Google searches throw up how to create a delegate or how to create the classic background worker but that's not at all what I need, although they may be part of the solution. So, is there a simple but generic structure that can be used? My level of C# is moderate and I've been programming all my working life, given a clue I'll figure it out (and post back)... Thanks in advance for any help.

    Read the article

< Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >