Search Results

Search found 9845 results on 394 pages for 'xbox controller'.

Page 251/394 | < Previous Page | 247 248 249 250 251 252 253 254 255 256 257 258  | Next Page >

  • Windows 7 Laptops "unable to find logon server"

    - by tombull89
    In the school I work in we have a large number (500+) of Windows 7 laptops on a Meru Wireless system and Server 2008 R2 Servers. We have an appalingly large failure rate where a student or staff member tries to logon (to the laptop joined to the domain) and is met by "There are currently no logon servers available to service the logon request". I've seen this question and this one and while removing and re-joining to the domain works, it's highly time consuming, irritating, and we (I) have more important things to concentrate on. The only MS KB article I can find is regarding a read-only domain controller (which ours isn't) and I'm at my wits end. Ultimately, is there a definitve cause and answer to this or am I stuck removing and re-joining the laptops?

    Read the article

  • Dell poweredge 1850's - wont install os

    - by user1326789
    I have 3 of these dell 1850 rack servers. 1 has 3GB RAM and 2 73GB HDD's. 2 have 6GB RAM and each of them has 2 73GB HDD's. I am currently trying to install an os on them but when i boot with windows xp setup, it gives me an error saying no partition found. Now i have set these drives up in RAID on the server and i put them "online" so it should be working fine but they're not. Please assist me in installing an operating system on these, i have no clue as to if it's the BIOS or the RAID controller within it. Thanks in advance, -Matt.

    Read the article

  • Hypertransport sync flood error

    - by Carl B
    What is it? And what causes it? Is it only for uncorrectable DIMM Errors(Troubleshooting DIMM errors)? When an UCE occurs, the memory controller causes an immediate reboot of the system. During reboot, the BIOS checks the Machine Check registers and determines that the previous reboot was due to an UCE, then reports this in POST after the memtest stage: A Hypertransport Sync Flood occurred on last boot 3 BIOS reports this event in the service processor’s system event log (SEL) as shown in the sample IPMItool output There are what seems to be some suggested answers to include Bad Caps Bios verisons (happens in one version not the other) Graphics card issues Lack of power to the CPU The list of possible generators seems to target everything but the computer case. System Specs: Windows Home Premium 64 Motherboard - MSI790FX-GD70 (MS7577) / Bios v 1.9 (American Megatrensa Inc) Ram - Patriot G Series ‘Sector 5’ Edition 4GB DDR3 1600 CPU - AMD Phenom II X2 555 Black Edition Callisto 3.2GHz Socket AM3 80W (Note: unlocked 2 cores CPU Z ids it as phenom II x4 B55) Graphics - 2 x Radeon 5750 in crossfire PSU - ABS 900w HDDs - 2 Seagate 1.5 TB Sata SSD - 1 OCZ 120 GB Vertex Plus R2

    Read the article

  • Rename Exchange Server 2003 Domain

    - by Debasish Pramanik
    Hi All: We have the following exchange server deployment Windows 2003 Server + Domain Controller + Exchange Server 2003 The domain name was X.COM. everything was working fine but due to some reason we need to rename the domain name to Y.COM. The rename of Domain went well but the rename of Exchange Server 2003 is having issues. When we run the XDR-Fixup we get the following error Operation failed: Could not get 'configurationNamingContext' on RootDSE of this server. Let me know if you have any idea on this.

    Read the article

  • AD, Windows-NT Authentication queries

    - by rockbala
    Need Help on the following questions. When a users login (on a computer in the network) is validated against AD what is/are the authentication method used? When a users login is validated in Windows NT environment (not AD) what is/are the authentication method used? If all user's account is on AD, is it possible to change the authentication mechanism only (or protocols) from AD to NT and vice versa (if possible)? If part/whole of question 3 is valid, where should one look to change these authentication methods ? What is the difference between AD and Windows-NT authentication ? Windows server 2008 Domain controller used. Regards, Balaji

    Read the article

  • IE does not send NTLM domain

    - by Buddy Casino
    I have a problem with NTLM single-sign-on with IE8. We've got multiple domain controllers and users from multiple domains that we try to authenticate to a web application via NTLMv1 passthru. Somehow IE fails to send the user's domain in the NTLM Type 1 message. This has the effect that the webapp can not match users properly to their domain controllers, resulting in failed logon attempts, because a user from domain X tries to authenticate to domain controller Y. This problem does not occur with Firefox, as it always sends the correct domain header. So: how do I get IE to send the domain in the NTLM header?

    Read the article

  • Laptop stopped recognizing USB hard drive

    - by vahokif
    Hi, My Packard Bell EasyNote TX86 laptop stopped recognizing my 1 TB Toshiba Store Art hard drive. It worked fine until now, and it still works on other computers. Other USB devices (including storage) work, and I've tried plugging it in every port, to no avail. When I plug it in it spins up, but Windows doesn't react at all (it's not in disk management), Linux doesn't write anything in dmesg and I can't see it in BIOS setup. I didn't use it at all today, apart from plugging it into a freshly-installed Windows 7 machine once (where it worked). What can I do? Which device is to blame here? EDIT: One more thing. I unplugged the drive while the laptop was hibernated. Google says this might be the problem and it might have something to do with resetting the USB Host Controller.

    Read the article

  • 64 Bit Windows drivers for Inspiron 1720

    - by Rob Allen
    Dell doesn't seem to offer 64 bit drivers specifically for the Inspiron 1720 (laptop). I'm going to be upgrading from Vista 32-bit to Windows 7 64bit and I want to pull down the necessary stuff before hand. Are there any Dell systems that are similar enough to the Inspiron 1720 that I can use for a baseline to make sure I still have Ethernet and WiFi after the reinstall? It doesn't matter if they are for Vista 64 or Windows 7. Identified hardware: Processor: Intel mobile Core 2 Duo T7500 Chipset: Intel Mobile 965 Express Wifi: Intel Pro Wireless Drive Controller: Intel Matrix Graphics: nVidia GeForce 8600M GT Bluetooth: Dell TrueMobile 355 + EDR Ricoh card reader I think anything else, the default Windows drivers will be sufficient. Let me know if you think I missed something thing please.

    Read the article

  • IBM x260m won't boot from PCI SATA card

    - by syrenity
    Hi. We ghosted our old Windows 2003 drive to a new 1TB one, and connected through new PCI SATA card. The x260m server fails to boot with error 1962: "Boot sector not found." When we connect the drive directly to motherboard, it boots fine, so the problem is probably in getting BIOS to boot from the SATA card. Has anyone encountered and solved such issue? EDIT: We tried disabling the on-board Sata controller (Hostraid/SAS?), but there is no such option - only enable, enhanced and compatible. Tried also to chance boot device priority to all possible choices - no luck. Thanks in advance!

    Read the article

  • iSCSI RAID1 on two servers, fail scenario

    - by Franz Kafka
    Hallo, a simple question: Image I have two servers, each server has two disks in RAID1. Now I merge the two arrays with iSCSI to one RAID1 disk. Two questions: Can I do the merging of the 4 disks in one go? I can't image how. First I will have to install the os, and then the raid controller is already set up to RAID1. If a whole server fails the other server would continue working without any problems? Does iSCSI notice that the other server is missing and treet this as if the two disks were broken? When the server comes back online the data is resynced, as if I installed new disks into a array? Can I image that this way? Thanks alot.

    Read the article

  • FreeNas running on ESXi - sometimes gets very slugish.

    - by Luma
    Hello everyone, I have a ESXi server (dual quad core, 8GB of DDR3 ram, 6x 1TB WD Blacks running in RAid 5 on the PErc 6/i controller. I have a 64bit freenas VM running, on this VM I keep about 200Gigs of stuff that my windows machines access. every now and then the throughput of this VM just dies, for example right now it can't even handle streaming a song and when I tried to transfer a folder the speed goes from 10-400KB/s. Might I add at this point that the ESXi box has dual gigabit network cards plugged into a good solid gigabit switch and other linux and windows VM's are just fine I have seen speeds over 90MB/s (frequently) The server still has ram left over (plenty actually) and cpu is very low (500-1000mhz) any ideas what could cause this? thanks. Luc

    Read the article

  • Wireless card not found on Ubuntu

    - by idealflip
    Hello all, I'm trying to setup Ubuntu on an old PC. I ran the following command, lspci, in order to get info on the wireless card installed. 00:0a.0 Ethernet controller: Marvell Technology Group Ltd. 88w8335 [Libertas] 802.11b/g Wireless (rev 03) Does anyone know where I can get drivers for this card/chip? And also, how to install (I'm rather new to linux). Also, I'm sure the card is working because I just formatted over xp, and everything was working well. Thanks in advanced!

    Read the article

  • Software RAID to hardware RAID, can it be done?

    - by gtaylor85
    Can it be done ... well. (For the record, I did not set this server up.) In my server there are 4 disks. 3 of them are in a software RAID5, and 1 has the OS installed. I want to buy a RAID controller, 4 new HDs and set up a hardware RAID5. If possible, I'd like to just image the current setup, and use it to build my new one. My questions are: Can I image a 3 disk RAID5 to 4 disk RAID5? Are there problems with this? What is considered best practice for your OS. To have it on a separate disk like it currently is, or to install it on the RAID5? Thank you. I can clarify anything. I'm not sure what other info might be pertinent.

    Read the article

  • How to make AD highly available for applications that use it as an LDAP service

    - by Beaming Mel-Bin
    Our situation We currently have many web applications that use LDAP for authentication. For this, we point the web application to one of our AD domain controllers using the LDAPS port (636). When we have to update the Domain Controller, this has caused us issues because one more web application could depend on any DC. What we want We would like to point our web applications to a cluster "virtual" IP. This cluster will consist of at least two servers (so that each cluster server could be rotated out and updated). The cluster servers would then proxy LDAPS connections to the DCs and be able to figure out which one is available. Questions For anyone that has had experience with this: What software did you use for the cluster? Any caveats? Or perhaps a completely different architecture to accomplish something similar?

    Read the article

  • b43 module loaded, but no interface showed up

    - by Eduardo Bezerra
    I'm using CentOS 6.3 x86_64 on a hardware with a BCM43224 chip for wi-fi. I installed the b43-fwcutter module and then run modprobe b43, with no error messages. However, no new network interface showed up, and the return of iwconfig is: lo no wireless extensions. eth0 no wireless extensions. lspci -nn | grep 43224 returns: 03:00.0 Network controller [0280]: Broadcom Corporation BCM43224 802.11a/b/g/n [14e4:4353] (rev 01) and uname -a: Linux localhost.localdomain 2.6.32-279.14.1.el6.x86_64 #1 SMP Tue Nov 6 23:43:09 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux Any ideas of how to make the wireless device work?

    Read the article

  • Multiple test Active Directory envirovments hand in hand with production domain controllers

    - by MadBoy
    What's the best approach of having multiple test environments next to production one? We have multiple programming teams that build solutions that use Active Directory very often. We have tried different approaches, starting with their own domain controllers (in same subnet), or additional OU's in our production AD that the team gets control over and can create/delete accounts within that one OU. We thought of possible 4 solutions: Setting up separate OU's in ou production env. Creating subdomains for our contoso.com domain like test.contoso.com, something.contoso.com and delegating control to the teams (would we need additional DC's or the two that we have already would be enough to hold this? Setting up additional test domain controler that has a trust to our main domain and all teams can use the test domain controler as they please. Setting up single domain controller for every team/project. We're taking in consideration amount of resources needed, security (for example having multiple domain controlers with multiple passwords may lead users to use simpler passwords) and overall best practices for this scenario.

    Read the article

  • Create and use intermediate certificate authority on Windows Server 2012?

    - by Sid
    Background: Server OS is Windows Server 2012. GUI is installed as we come upto speed with powershell. Setup is staging, not production (yet). We have our (internal, domain limited) Root CA installed. I would like to take the Root CA offline to secure storage but before that I'd like to setup an intermediate CA which can take over actual live, online (int-RA-net) functionality Can someone guide me covering: creating the intermediate CA certificate request installing the intermediate CA certificate on domain controller (certification authority role already installed with Root CA online right now) use the intermediate CA to generate a certificate (any use certificate, just for demonstration purposes) Obviously this certification chain would be invalid on computers outside our domain (self trusted root - our root certificate is NOT from common 3rd parties). This last point is NOT a problem.

    Read the article

  • SQL 2008 network logon

    - by gledhilla
    Hi I have a domain controller that I have installed active directory onto and have set up an account that I want to use for my SQL server installation on another computer that is linked onto the domain. I can search for the account in active directory and I am able to select it into the add new user section in MSSMS, however, when I click add I get 'Windows NT user or group 'DOMAIN\user' not found. Check the name again. (Microsoft SQL Server, Error: 15401) I have googled the Error code and I havent found a solution that has fixed the error. If you have any help I would be greatful Thanks :)

    Read the article

  • CentOS - Add additional hard drive raid arrays on Dell Perc 5/i card

    - by Quanano
    We have a Dell Poweredge 2900 system with Dell Perc 5/i card and 4 SAS hard drives attached, with NTFS partitions on them. We installed CentOS on one raid array on this controller with a different controller and it is working fine. We are now trying to access the drives shown above and they are not being shown in /dev as sdb, etc. sda is the drive that we installed centos on and it has sda1, sda2, sda3, etc. The CDROM has been picked up as well. If I scan for scsi devices then the perc and adaptec controllers are both found. sg0 is the CDROM and sg2 is the centos installed, however I think sg1 is the other drive but I cannot see anyway to mount the partitions, as only the drive is listed in /dev. Thanks. EXTRA INFO fdisk -l: Disk /dev/sda: 72.7 GB, 72746008576 bytes 255 heads, 63 sectors/track, 8844 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x11e3119f Device Boot Start End Blocks Id System /dev/sda1 * 1 64 512000 83 Linux Partition 1 does not end on cylinder boundary. /dev/sda2 64 8845 70528000 8e Linux LVM Disk /dev/mapper/vg_lal2server-lv_root: 34.4 GB, 34431041536 bytes 255 heads, 63 sectors/track, 4186 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_root doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_swap: 21.1 GB, 21139292160 bytes 255 heads, 63 sectors/track, 2570 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_swap doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_home: 16.6 GB, 16647192576 bytes 255 heads, 63 sectors/track, 2023 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_home doesn't contain a valid partition table These are all from the install hdd not the additional hard drives modprobe a320raid FATAL: Module a320raid not found. lsscsi -v: [0:0:0:0] cd/dvd TSSTcorp CDRWDVD TS-H492C DE02 /dev/sr0 dir: /sys/bus/scsi/devices/0:0:0:0 [/sys/devices/pci0000:00/0000:00:1f.1/host0/target0:0:0/0:0:0:0] [4:0:10:0] enclosu DP BACKPLANE 1.05 - dir: /sys/bus/scsi/devices/4:0:10:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:0:10/4:0:10:0] [4:2:0:0] disk DELL PERC 5/i 1.03 /dev/sda dir: /sys/bus/scsi/devices/4:2:0:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:2:0/4:2:0:0] . lsmod: Module Size Used by fuse 66285 0 des_generic 16604 0 ecb 2209 0 md4 3461 0 nls_utf8 1455 0 cifs 278370 0 autofs4 26888 4 ipt_REJECT 2383 0 ip6t_REJECT 4628 2 nf_conntrack_ipv6 8748 2 nf_defrag_ipv6 12182 1 nf_conntrack_ipv6 xt_state 1492 2 nf_conntrack 79453 2 nf_conntrack_ipv6,xt_state ip6table_filter 2889 1 ip6_tables 19458 1 ip6table_filter ipv6 322029 31 ip6t_REJECT,nf_conntrack_ipv6,nf_defrag_ipv6 bnx2 79618 0 ses 6859 0 enclosure 8395 1 ses dcdbas 9219 0 serio_raw 4818 0 sg 30124 0 iTCO_wdt 13662 0 iTCO_vendor_support 3088 1 iTCO_wdt i5000_edac 8867 0 edac_core 46773 3 i5000_edac i5k_amb 5105 0 shpchp 33482 0 ext4 364410 3 mbcache 8144 1 ext4 jbd2 88738 1 ext4 sd_mod 39488 3 crc_t10dif 1541 1 sd_mod sr_mod 16228 0 cdrom 39771 1 sr_mod megaraid_sas 77090 2 aic79xx 129492 0 scsi_transport_spi 26151 1 aic79xx pata_acpi 3701 0 ata_generic 3837 0 ata_piix 22846 0 radeon 1023359 1 ttm 70328 1 radeon drm_kms_helper 33236 1 radeon drm 230675 3 radeon,ttm,drm_kms_helper i2c_algo_bit 5762 1 radeon i2c_core 31276 4 radeon,drm_kms_helper,drm,i2c_algo_bit dm_mirror 14101 0 dm_region_hash 12170 1 dm_mirror dm_log 10122 2 dm_mirror,dm_region_hash dm_mod 81500 11 dm_mirror,dm_log blkid: /dev/sda1: UUID="bc4777d9-ae2c-4c58-96ea-cedb342b8338" TYPE="ext4" /dev/sda2: UUID="j2wRZr-Mlko-QWBR-BndC-V2uN-vdhO-iKCuYu" TYPE="LVM2_member" /dev/mapper/vg_lal2server-lv_root: UUID="9238208a-1daf-4c3c-aa9b-469f0387ebee" TYPE="ext4" /dev/mapper/vg_lal2server-lv_swap: UUID="dbefb39c-5871-4bc9-b767-1ef18f12bd3d" TYPE="swap" /dev/mapper/vg_lal2server-lv_home: UUID="ec698993-08b7-443e-84f0-9f9cb31c5da8" TYPE="ext4" dmesg shows: megaraid_sas: fw state:c0000000 megasas: fwstate:c0000000, dis_OCR=0 scsi2 : LSI SAS based MegaRAID driver scsi 2:0:0:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:1:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:2:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:3:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:4:0: Direct-Access HITACHI HUS154545VLS300 D590 PQ: 0 ANSI: 5 scsi 2:0:5:0: Direct-Access HITACHI HUS154545VLS300 D590 PQ: 0 ANSI: 5 scsi 2:0:8:0: Direct-Access FUJITSU MBA3073RC D305 PQ: 0 ANSI: 5 scsi 2:0:9:0: Direct-Access FUJITSU MBA3073RC D305 PQ: 0 ANSI: 5 i.e. the 3 RAID Arrays Seagate Hitatchi and Fujitsu hard drives respectively. FURTHER UPDATE I have installed the megaraid storage manager console and connected to the server. It appears that the two CentOS installation hard drives are OK. The other 6 drives, one raid array of 4 and one raid array of 2 disks. The other drives are listed as (Foreign) Unconfigured Good.

    Read the article

  • Battery backed write cache behavior upon disk change

    - by Halfgaar
    We use 3ware Inc 9650SE SATA-II RAID PCIe RAID controllers with battery backed write cache. Our spare hardware has the same controller. I was wondering; are these controllers smart enough not to sync the cache when the disks have been changed? For example, if I deploy one of those spare machines by putting in the disks of another machine and that spare machine still has pending writes, will it be smart enough not to perform those writes on the replaced array? Edit: my scenario is not really made clear, so let me give an example: server1 goes down because of power supply failure. I put the disks in server2 and start. I repair server1 I put the disks back from server2 in server1 (it's not relevant right now that in reality I would probably keep server2 running). If server1 doesn't have safeguards, it will write to the array, thinking it's simply powering up again, corrupting it.

    Read the article

  • Authorization error when testing FTP to UNC

    - by user64204
    We have a Windows Server 2008 R2 with Active Directory (hereafter called DC) running as a domain controller on which we have IIS and an FTP site installed. We have a second Server 2008 (hereafter called SHARE) which is joined to that domain and has a disk shared as a network share (\\share\Office). That network share is used as the ftp's physical path on DC. We've tested the FTP from the IIS FTP configuration panel, by clicking on Basic Settings... then Test Settings.... When setting Administrator as a username with the Connect as... option, everything is fine: When no user is provided we can the below error: Q1: Could someone explain in more understandable terms what is written in the Details text area?

    Read the article

  • HP Proliant DL360 G5 + MSA50 RAID Setup recommendations

    - by JohnRB
    I am running a HP Proliant DL360 2 x 3GHz Xeon 16GB Ram P400 integrated RAID card with 6 x 73GB SAS HDDs running Ubuntu Server 14.04 CLI only. I recently got my hands on a MSA50 SAS Enclosure (10 x SAS HDD bays w/ SAS in/out interface) and wondering what you guys recommended as far as an addon raid controller for one of the pciex slots. I have both slots free Full and Half sizes. Any suggestions are greatly appreciated, I am an I.T. Consultant but have not used these particular units before so I was hoping to hear from someone who has. Thanks!

    Read the article

  • Server 2003 RAS Server Utilising High WAN Traffic

    - by Joe Sergeant
    We have Routing and Remote Access configured on Server 2003 (also our primary domain controller), allowing users to connect in remotely to access files, email, etc. With one user, the RAS Server is constantly sending data to that user's remote computer. From 9am this morning it has transferred almost 800MB. The user isn't transferring any files remotely, certainly not enough to total 800MB anyway. None of the other remote users have had this issue. We have ensured that the user in question has "Use default gateway on remote network" disabled for both IPv4 and IPv6 and we are fairly confident that Offline Files isn't trying to synchronise with the server remotely, too. My question is two-fold. Firstly, has anyone had a similar experience? Secondly, what would be the best software to discover exactly what data is being sent to the remote user?

    Read the article

  • stdout and key press

    - by Jack
    Hi, when in console, if I press a key, some interrupt controller sends code of that key to CPU, which looks into some table and than represent that keypress by printing some charracter to stdout. But, is keyboard sending an ASCII code of that key, or just some standardised code? Since there is so many languages and extra characters, OS must further translate its code into some character according to user selected scheme, I guess. I ask, becouse I am from Czech Republic, and we use some characters that do not exists in standart ASCII code. So I was thinking, if I enter this character into a console, and then print it, lets say in C++ using cin and cout, and I have set locale to Czech, stdin must actually send some non-ASCII code of the character I pressed to input stream. Am I right?

    Read the article

  • Ubuntu 10.04 recognizing USB 2.0 external HD as USB 1.1

    - by btucker
    When I connect the USB 2.0 drive I see this: usb 1-4.3: new full speed USB device using ohci_hcd and address 5 so I know it's getting seen as USB 1.1. usb-devices shows that it really is USB 2.0 and connected to a USB 2.0 hub: T: Bus=01 Lev=01 Prnt=01 Port=03 Cnt=01 Dev#= 2 Spd=12 MxCh= 4 D: Ver= 2.00 Cls=09(hub ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=05e3 ProdID=0608 Rev=77.61 S: Product=USB2.0 Hub C: #Ifs= 1 Cfg#= 1 Atr=e0 MxPwr=100mA I: If#= 0 Alt= 0 #EPs= 1 Cls=09(hub ) Sub=00 Prot=00 Driver=hub T: Bus=01 Lev=02 Prnt=02 Port=01 Cnt=01 Dev#= 4 Spd=12 MxCh= 0 D: Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=13fd ProdID=1340 Rev=02.10 S: Manufacturer=Generic S: Product=External C: #Ifs= 1 Cfg#= 1 Atr=c0 MxPwr=2mA I: If#= 0 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage It seems the problem is that root hub is: T: Bus=01 Lev=00 Prnt=00 Port=00 Cnt=00 Dev#= 1 Spd=12 MxCh=10 D: Ver= 1.10 Cls=09(hub ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=1d6b ProdID=0001 Rev=02.06 S: Manufacturer=Linux 2.6.32-25-server ohci_hcd S: Product=OHCI Host Controller S: SerialNumber=0000:00:02.0 C: #Ifs= 1 Cfg#= 1 Atr=e0 MxPwr=0mA I: If#= 0 Alt= 0 #EPs= 1 Cls=09(hub ) Sub=00 Prot=00 Driver=hub And there's no mention of ehci_hcd. lsusb -t gives me: /: Bus 01.Port 1: Dev 1, Class=root_hub, Driver=ohci_hcd/10p, 12M |__ Port 4: Dev 2, If 0, Class=hub, Driver=hub/4p, 12M |__ Port 2: Dev 4, If 0, Class=stor., Driver=usb-storage, 12M |__ Port 3: Dev 5, If 0, Class=stor., Driver=usb-storage, 12M |__ Port 6: Dev 3, If 0, Class=stor., Driver=usb-storage, 12M It seems like I'm missing something which would allow the OS to see USB 2.0 devices. Can anyone point me in the right direction? EDIT Full lsusb -v output: Bus 001 Device 005: ID 13fd:1340 Initio Corporation Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x13fd Initio Corporation idProduct 0x1340 bcdDevice 2.10 iManufacturer 1 Generic iProduct 2 External iSerial 3 57442D574341595930323337 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 2mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc. USB-2.0 4-Port HUB Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x05e3 Genesys Logic, Inc. idProduct 0x0608 USB-2.0 4-Port HUB bcdDevice 77.61 iManufacturer 0 iProduct 1 USB2.0 Hub iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 100mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0001 1x 1 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x00e0 Ganged power switching Ganged overcurrent protection Port indicators bPwrOn2PwrGood 50 * 2 milli seconds bHubContrCurrent 100 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0103 power enable connect Port 3: 0000.0103 power enable connect Port 4: 0000.0100 power Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 1 Single TT bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 001 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0001 1.1 root hub bcdDevice 2.06 iManufacturer 3 Linux 2.6.32-25-server ohci_hcd iProduct 2 OHCI Host Controller iSerial 1 0000:00:02.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 11 bDescriptorType 41 nNbrPorts 10 wHubCharacteristic 0x0002 No power switching (usb 1.0) Ganged overcurrent protection bPwrOn2PwrGood 1 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 0x00 PortPwrCtrlMask 0xff 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0103 power enable connect Port 5: 0000.0100 power Port 6: 0000.0103 power enable connect Port 7: 0000.0100 power Port 8: 0000.0100 power Port 9: 0000.0100 power Port 10: 0000.0100 power Device Status: 0x0003 Self Powered Remote Wakeup Enabled

    Read the article

< Previous Page | 247 248 249 250 251 252 253 254 255 256 257 258  | Next Page >