  • ext4 filesystem corruption -- maybe hardware error?

    - by pts
    I'm getting these errors in dmesg after about half an hour after I turn on the computer: [ 1355.677957] EXT4-fs error (device sda2): htree_dirblock_to_tree: inode #1318420: (comm updatedb.mlocat) bad entry in directory: directory entry across blocks - block=5251700offset=0(0), inode=1802725748, rec_len=179136, name_len=32 [ 1355.677973] Aborting journal on device sda2-8. [ 1355.678101] EXT4-fs (sda2): Remounting filesystem read-only [ 1355.690144] EXT4-fs error (device sda2): htree_dirblock_to_tree: inode #1318416: (comm updatedb.mlocat) bad entry in directory: directory entry across blocks - block=5251699offset=0(0), inode=2194783952, rec_len=53280, name_len=152 [ 1356.864720] EXT4-fs error (device sda2): htree_dirblock_to_tree: inode #1312795: (comm updatedb.mlocat) bad entry in directory: directory entry across blocks - block=5251176offset=1460(13748), inode=1432317541, rec_len=208208, name_len=119 /dev/sda is an SSD, and it's using the noop scheduler. /etc/fstab entry: UUID=acb4eefa-48ff-4ee1-bb5f-2dccce7d011f / ext4 errors=remount-ro,noatime,discard,user_xattr 0 1 System information: $ cat /proc/mounts | grep /dev/sd /dev/sda1 /boot ext2 rw,noatime,errors=continue 0 0 $ cat /etc/lsb-release DISTRIB_ID=Ubuntu DISTRIB_RELEASE=10.04 DISTRIB_CODENAME=lucid DISTRIB_DESCRIPTION="Ubuntu 10.04.3 LTS" $ uname -a Linux leetpad 2.6.35-30-generic-pae #61~lucid1-Ubuntu SMP Thu Oct 13 21:14:29 UTC 2011 i686 GNU/Linux I've run memtest for 7 hours, it didn't found any memory errors. Any obvious ideas what can go wrong in this case? The most reasonable thing I can imagine is that the SSD is silently dropping some write requests, which eventually leads to an EXT4 filesystem inconsistency (but no disk I/O errors). How can this happen? Is there a relevant configuration option I should ensure to be set correctly? What tools should I use to diagnose the hardware failures? Would it be possible to diagnose the SSD failure without overwriting data?

    Read the article

  • Screen Flickering: Hardware or Software?

    - by Wesley
    I have a Samsung N120 netbook (upgraded to 2GB DDR2 RAM) and there has been a screen flickering issue for some time now. However, I have not been able to accurately determine whether it is a software or hardware issue. Here are some of the symptoms: The flicker is white-colored and shows up as vertical lines. Flickering or not, there may be occasionally some random blue patterns (no image distortion) The screen tends to flicker more when the screen is not tilted back all the way. When tilting the screen back and forth, the screen will usually flicker. Some images on the screen may randomly distort without full-on flickering. The screen will flicker only on certain websites, but not on others. A certain part of a webpage may constantly be distorted randomly, even when scrolling. While flickering, the mouse will not move though I'm moving my finger along the touchpad. A connected external monitor does not have any problems. The flickering is completely random and does not seem to follow any CPU/GPU usage trends. Flickering usually gets worse when the screen brightness is turned higher. There will be flickering on battery and while plugged in. Search up "Samsung N120 - Screen Flickering" on YouTube for an idea of what the flickering looks like. However, there is no visible distortions and the flickering seems to stop when the screen has dimmed. Since the problems started, I tried formatting and using Windows 7, then formatted again and went back to Windows XP. The screen was also replaced sometime during this past summer. The uninstallation of the Samsung Battery Manager (on the original install of XP) seemed to reduce the flicker partially, but eventually got worse. So, what could possibly be the problem?

    Read the article

  • Piecing together low-powered hardware for an RS-232 terminal server

    - by Fred
    I'm working on reconstructing my Cisco lab for training/educational purposes and I found that the actual terminal server I have is dead. I have a couple of 8-port PCI serial cards which would be more than ample for my lab, but I don't want to leave my personal computer running to be able to access the console ports. Ideally I would access the terminal server remotely, either by SSH/RDP to the box (depending on what OS I go with) or by installing a software package that allows me to telnet directly to a serial port. I know I've found a program that does this under Linux in the past but its name escapes me at the moment. I'm thinking about scavenging for some old hardware, on eBay or something, to put together a low-powered PC. Needs to be something that: Has Low-power consumption Has at least 2 PCI slots (though I certainly wouldn't complain about having more) Has onboard Ethernet (or, if not, another PCI or ISA slot (not shared)) Can be headless once an OS installed (probably Linux) I'm currently leaning towards an old fashioned Pentium (sub-133MHz era) but I am wondering if anybody else knows of another platform/mobo that would suit these needs. Alternatively, I've been considering buying a Raspberry Pi and a big USB hub along with a bunch of USB-Serial adapters but this sounds like it'd get messy quick with cables and adapters all over the place, and I may not even have the same ttyS#'s between boots.

    Read the article

  • Inexpensive (used) hardware for Xen virtualization test?

    - by Jason Antman
    Virtualization is one of the areas where I could really use some experience. I also run quite a few services (web, mail, dns, etc.) out of my home. Since most of my hardware is getting a bit old (I'm running on stuff that was surplused years ago...) I decided that it's about time I start renewing some things, and also play around with virtualization a bit more. My plan is to setup a SAN box (simple iSCSI target, relatively inexpensive gigE switch), get a pair (for starters) of new servers, and start building some new stuff with Xen, specifically planning on playing with live migration and full virtualization. Does anyone have recommendations for used, older "servers" (really anything in a rack-mount form factor, I'm not too worried about things like iLO/iLOM for the test nodes) that support VT-x/AMD-V? I'm biased to HP, but it looks like they didn't make Proliants with VT-x/Vanderpool processors until G6 (for the DL360) or so, which is way out of my price range. I'm looking in the sub-$300 range (or less, if possible), used, probably Ebay. Any recommendations are greatly appreciated. Edit:And, to catch this before the comments start coming - these are personal systems. I have first-generation Proliants still in use (I got them as corporate surplus in 05, they've been running since then, and probably were running since 01 or 02 prior to being sold). I don't need anything shiny and new - I've got a bunch of old boxes, at least one complete replacement for every model in use, and that's fine for me (and easy on the wallet).

    Read the article

  • mdadm: Replacing array with entirely new drives

    - by hellfur
    I have a server with three 500GB drives, with most of my data in a RAID5 configuration spanning the three of them. I just purchased and installed four 1TB drives, and the intention is to move off of the old drives and onto the new ones. I have enough SATA ports and power connectors to power all seven of my drives at once, so I've kept the old RAID running while I figure out what to do with the new drives. My question is: Should I create a whole new array on the 1TB drives, then move everything over and reconfigure linux to boot from the new md arrays? Or should I just expand the array, swapping out each of the three 500GBs with the 1TB, then adding the final drive? I've read up on the mdadm extending drive setup, and it makes sense, but I imagine I would use one of the drives as a full backup while I move things over, then add that drive back into the array once things are up and running on three of the 1TB drives, so there's some complication in going that route as well... I'm just not sure which is safer/recommended.

    Read the article

  • How to remove RAID flag on unstriped drive without losing data?

    - by Alex Folland
    I have a Gigabyte Z68X-UD4-B3 motherboard. It advertises this new thing called "XHD", which is like RAID but makes a SSD and traditional-style drive work together to enable high speed with high capacity. I don't want to use this feature, and I already have Windows 7 64 installed without using this feature. When I first installed my 2 hard drives (1 SSD and 1 traditional-style drive) in my machine and booted it up for the first time, it ran a program from the mobo that asked me if I wanted to set up XHD. Thinking it would go to some config screen, I said yes. It immediately started doing something with my drives and finished. I considered that strange, but figured it wouldn't matter when I simply install Windows onto my SSD only. I now have my BIOS and Windows running in AHCI mode with no RAID arrays and separate drives. My SSD is one of those new Corsair Force GT drives which loses power every so often, causing Windows to BSOD. I've figured everything out about this problem, including installing the latest firmware from Corsair, and the only way to fix it at this point is by installing Intel Rapid Storage Technology to control AHCI instead of Windows, since the Windows AHCI driver disables the drive's power every once in a while and can't be configured not to do so. I've tried installing Intel Rapid Storage Technology. When I reboot my machine after doing so, it BSODs just after the Windows logo. I've figured out this is because my SSD and my traditional drive are flagged as RAID, as seen in the "Intel Matrix Storage Manager" program found by switching the BIOS hard drive handling to "RAID" mode. This is due to the XHD auto-config program I mentioned earlier. Normally, the BIOS is set to AHCI, and when the drives boot in AHCI mode, they work perfectly. So, I've concluded the data is stored in AHCI mode but the drives' flags are set to RAID. I've figured out that I can accomplish my objective by using the "Intel Matrix Storage Manager" program on the mobo (with "Reset disks to non-RAID"), but doing so would cause it to completely wipe the drives I select. I want to simply toggle these flags from RAID to AHCI so Intel Rapid Storage Technology doesn't fail and cause a BSOD upon booting, but without wiping the drives.

    Read the article

  • IBM Keynote: (hardware,software)–>{IBM.java.patterns}

    - by Janice J. Heiss
    On Sunday evening, September 30, 2012, Jason McGee, IBM Distinguished Engineer and Chief Architect Cloud Computing, along with John Duimovich IBM Distinguished Engineer and Java CTO, gave an information- and idea-rich keynote that left Java developers with much to ponder.Their focus was on the challenges to make Java more efficient and productive given the hardware and software environments of 2012. “One idea that is very interesting is the idea of multi-tenancy,” said McGee, “and how we can move up the spectrum. In traditional systems, we ran applications on dedicated middleware, operating systems and hardware. A lot of customers still run that way. Now people introduce hardware virtualization and share the hardware. That is good but there is a lot more we can do. We can share middleware and the application itself.” McGee challenged developers to better enable the Java language to function in these higher density models. He spoke about the need to describe patterns that help us grasp the full environment that an application needs, whether it’s a web or full enterprise application. Developers need to understand the resources that an application interacts with in a way that is simple and straightforward. The task is to then automate that deployment so that the complexity of infrastructure can be by-passed and developers can live in a simpler world where the cloud can automatically configure the needed environment. McGee argued that the key, something IBM has been working on, is to use a simpler pattern that allows a cloud-based architecture to embrace the entire infrastructure required for an application and make it highly available, scalable and able to recover from failure. The cloud-based architecture would automate the complexity of setting up and managing the infrastructure. IBM has been trying to realize this vision for customers so they can describe their Java application environment simply and allow the cloud to automate the deployment and management of applications. “The point,” explained McGee, “is to package the executable used to describe applications, to drop it into a shared system and let that system provide some intelligence about how to deploy and manage those applications.”John Duimovich on Improvements in JavaMcGee then brought onstage IBM’s Distinguished Engineer and CTO for Java, John Duimovich, who showed the audience ways to deploy Java applications more efficiently.Duimovich explained that, “When you run lots of copies of Java in the cloud or any hypervisor virtualized system, there are a lot of duplications of code and jar files. IBM has a facility called ‘shared classes’ where we put shared code, read only artefacts in a cache that is sharable across hypervisors.” By putting JIT code in ahead of time, he explained that the application server will use 20% less memory and operate 30% faster.  He described another example of how the JVM allows for the maximum amount of sharing that manages the tenants and file sockets and memory use through throttling and control. Duimovich touched on the “thin is in” model and IBM’s Liberty Profile and lightweight runtime for the cloud, which allows for greater efficiency in interacting with the cloud.Duimovich discussed the confusion Java developers experience when, for example, the hypervisor tells them that that they have 8 and then 4 and then 16 cores. “Because hypervisors are virtualized, they can change based on resource needs across the hypervisor layer. You may have 10 instances of an operation system and you may need to reallocate memory, " explained Duimovich.  He showed how to resize LPARs, reallocate CPUs and migrate applications as needed. He explained how application servers can resize thread pools and better use resources based on information from the hypervisors.Java Challenges in Hardware and SoftwareMcGee ended the keynote with a summary of upcoming hardware and software challenges for the Java platform. He noted that one reason developers love Java is it allows them to ignore differences in hardware. He stated that the most important things happening in hardware were in network and storage – in developments such as the speed of SSD, the exploitation of high-speed, low-latency networking, and recent developments such as storage-class memory, and non-volatile main memory. “So we are challenged to maintain the benefits of Java and the abstraction it provides from hardware while still exploiting the new innovations in hardware,” said McGee.McGee discussed transactional messaging applications where developers send messages transactionally persist a message to storage, something traditionally done by backing messages on spinning disks, something mostly outdated. “Now,” he pointed out, “we would use SSD and store it in Flash and get 70,000 messages a second. If we stored it using a PCI express-based flash memory device, it is still Flash but put on a PCI express bus on a card closer to the CPU. This way I get 300,000 messages a second and 25% improvement in latency.” McGee’s central point was that hardware has a huge impact on the performance and scalability of applications. New technologies are enabling developers to build classes of Java applications previously unheard of. “We need to be able to balance these things in Java – we need to maintain the abstraction but also be able to exploit the evolution of hardware technology,” said McGee. According to McGee, IBM's current focus is on systems wherein hardware and software are shipped together in what are called Expert Integrated Systems – systems that are pre-optimized, and pre-integrated together. McGee closed IBM’s engaging and thought-provoking keynote by pointing out that the use of Java in complex applications is increasingly being augmented by a host of other languages with strong communities around them – JavaScript, JRuby, Scala, Python and so forth. Java developers now must understand the strengths and weaknesses of such newcomers as applications increasingly involve a complex interconnection of languages.

    Read the article

  • Raid0 setup - What should 'my computer' say?

    - by superexsl
    Hey, I'm not a hardware person, so maybe someone here could help me. I ordered a PC from Dell that has "Serial ATA Raid 0 "Stripe"(7200RPM)Dual HDD" (2x500gb). However, I've just noticed that there's only one HD of 1TB (which is the default option when ordering). Should I be seeing two HDDs in "My Computer" or does the Raid0 setup simply improve performance rather than have (and display) two individual HDDs? How can I check if my computer does have a 'raid0' setup? Thanks

    Read the article

  • DIR $file "File Not Found" vs DIR $filedir shows it....not permissions, not USB

    - by Kev
    I was having this problem before on a USB drive, but now it's happening on my main RAID5-backed hard disk: 2013-10-17 9:37 C:\>dir "C:\Shares\Shared\Reference\Safety Management System\Vid eo CD\AutoPlay\Docs\Manuel*" Volume in drive C has no label. Volume Serial Number is 3C18-E114 Directory of C:\Shares\Shared\Reference\Safety Management System\Video CD\AutoP lay\Docs 2003-09-09 11:29 PM 1,056,768 Manuel d'intervention d'urgence MFC.doc 2004-06-20 10:36 PM 139,849 Manuel d'intervention d'urgence MFC.pdf 2 File(s) 1,196,617 bytes 0 Dir(s) 196,068,691,968 bytes free 2013-10-17 9:38 C:\>dir "C:\Shares\Shared\Reference\Safety Management System\Vid eo CD\AutoPlay\Docs\Manuel d'intervention d'urgence MFC.doc" Volume in drive C has no label. Volume Serial Number is 3C18-E114 Directory of C:\Shares\Shared\Reference\Safety Management System\Video CD\AutoP lay\Docs File Not Found 2013-10-17 9:38 C:\> This is from a Command Prompt window where I went to Properties and told it I wanted to modify who it ran as. I opened it, had it run as me with the "restricted access" unchecked, then ran the above. The file in question has the following ACLs: Administrators, SYSTEM, and OurCompanyUsers. All three have full control of everything. Nobody has any Deny bits set. I am a member of Administrators. So I don't believe it's a permissions issue. It's not a USB drive, so this time there is no question of USB hardware. Windows Server 2003 Standard Edition SP2. What does this mean? Is this more likely a hardware or software problem?

    Read the article

  • 2 drives, slow software RAID1 (md)

    - by bart613
    Hello, I've got a server from hetzner.de (EQ4) with 2* SAMSUNG HD753LJ drives (750G 32MB cache). OS is CentOS 5 (x86_64). Drives are combined together into two RAID1 partitions: /dev/md0 which is 512MB big and has only /boot partitions /dev/md1 which is over 700GB big and is one big LVM which hosts other partitions Now, I've been running some benchmarks and it seems like even though exactly the same drives, speed differs a bit on each of them. # hdparm -tT /dev/sda /dev/sda: Timing cached reads: 25612 MB in 1.99 seconds = 12860.70 MB/sec Timing buffered disk reads: 352 MB in 3.01 seconds = 116.80 MB/sec # hdparm -tT /dev/sdb /dev/sdb: Timing cached reads: 25524 MB in 1.99 seconds = 12815.99 MB/sec Timing buffered disk reads: 342 MB in 3.01 seconds = 113.64 MB/sec Also, when I run eg. pgbench which is stressing IO quite heavily, I can see following from iostat output: Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 231.40 0.00 298.00 0.00 9683.20 32.49 0.17 0.58 0.34 10.24 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 231.40 0.00 298.00 0.00 9683.20 32.49 0.17 0.58 0.34 10.24 sdb 0.00 231.40 0.00 301.80 0.00 9740.80 32.28 14.19 51.17 3.10 93.68 sdb1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sdb2 0.00 231.40 0.00 301.80 0.00 9740.80 32.28 14.19 51.17 3.10 93.68 md1 0.00 0.00 0.00 529.60 0.00 9692.80 18.30 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-0 0.00 0.00 0.00 0.60 0.00 4.80 8.00 0.00 0.00 0.00 0.00 dm-1 0.00 0.00 0.00 529.00 0.00 9688.00 18.31 24.51 49.91 1.81 95.92 Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 152.40 0.00 330.60 0.00 5176.00 15.66 0.19 0.57 0.19 6.24 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 152.40 0.00 330.60 0.00 5176.00 15.66 0.19 0.57 0.19 6.24 sdb 0.00 152.40 0.00 326.20 0.00 5118.40 15.69 19.96 55.36 3.01 98.16 sdb1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sdb2 0.00 152.40 0.00 326.20 0.00 5118.40 15.69 19.96 55.36 3.01 98.16 md1 0.00 0.00 0.00 482.80 0.00 5166.40 10.70 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-1 0.00 0.00 0.00 482.80 0.00 5166.40 10.70 30.19 56.92 2.05 99.04 Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 181.64 0.00 324.55 0.00 5445.11 16.78 0.15 0.45 0.21 6.87 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 181.64 0.00 324.55 0.00 5445.11 16.78 0.15 0.45 0.21 6.87 sdb 0.00 181.84 0.00 328.54 0.00 5493.01 16.72 18.34 61.57 3.01 99.00 sdb1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sdb2 0.00 181.84 0.00 328.54 0.00 5493.01 16.72 18.34 61.57 3.01 99.00 md1 0.00 0.00 0.00 506.39 0.00 5477.05 10.82 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-1 0.00 0.00 0.00 506.39 0.00 5477.05 10.82 28.77 62.15 1.96 99.00 And this is completely getting me confused. How come two exactly the same specced drives have such a difference in write speed (see util%)? I haven't really paid attention to those speeds before, so perhaps that something normal -- if someone could confirm I would be really grateful. Otherwise, if someone have seen such behavior again or knows what is causing such behavior I would really appreciate answer. I'll also add that both "smartctl -a" and "hdparm -I" output are exactly the same and are not indicating any hardware problems. The slower drive was changed already two times (to new ones). Also I asked to change the drives with places, and then sda were slower and sdb quicker (so the slow one was the same drive). SATA cables were changed two times already.

    Read the article

  • Is my hard drive about to die?

    - by Hristo Deshev
    I have two hard drives set up as a RAID 1 array on my server (Linux, software RAID using mdadm) and one of them just got me this "present" in syslog: Nov 23 02:05:29 h2 kernel: [7305215.338153] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:29 h2 kernel: [7305215.338178] ata1.00: irq_stat 0x40000008 Nov 23 02:05:29 h2 kernel: [7305215.338197] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:29 h2 kernel: [7305215.338220] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:29 h2 kernel: [7305215.338221] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:29 h2 kernel: [7305215.338287] ata1.00: status: { DRDY ERR } Nov 23 02:05:29 h2 kernel: [7305215.338305] ata1.00: error: { UNC } Nov 23 02:05:29 h2 kernel: [7305215.358901] ata1.00: configured for UDMA/133 Nov 23 02:05:32 h2 kernel: [7305218.269054] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:32 h2 kernel: [7305218.269081] ata1.00: irq_stat 0x40000008 Nov 23 02:05:32 h2 kernel: [7305218.269101] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:32 h2 kernel: [7305218.269125] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:32 h2 kernel: [7305218.269126] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:32 h2 kernel: [7305218.269196] ata1.00: status: { DRDY ERR } Nov 23 02:05:32 h2 kernel: [7305218.269215] ata1.00: error: { UNC } Nov 23 02:05:32 h2 kernel: [7305218.341565] ata1.00: configured for UDMA/133 Nov 23 02:05:35 h2 kernel: [7305221.193342] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:35 h2 kernel: [7305221.193368] ata1.00: irq_stat 0x40000008 Nov 23 02:05:35 h2 kernel: [7305221.193386] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:35 h2 kernel: [7305221.193408] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:35 h2 kernel: [7305221.193409] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:35 h2 kernel: [7305221.193474] ata1.00: status: { DRDY ERR } Nov 23 02:05:35 h2 kernel: [7305221.193491] ata1.00: error: { UNC } Nov 23 02:05:35 h2 kernel: [7305221.388404] ata1.00: configured for UDMA/133 Nov 23 02:05:38 h2 kernel: [7305224.426316] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:38 h2 kernel: [7305224.426343] ata1.00: irq_stat 0x40000008 Nov 23 02:05:38 h2 kernel: [7305224.426363] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:38 h2 kernel: [7305224.426387] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:38 h2 kernel: [7305224.426388] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:38 h2 kernel: [7305224.426459] ata1.00: status: { DRDY ERR } Nov 23 02:05:38 h2 kernel: [7305224.426478] ata1.00: error: { UNC } Nov 23 02:05:38 h2 kernel: [7305224.498133] ata1.00: configured for UDMA/133 Nov 23 02:05:41 h2 kernel: [7305227.400583] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:41 h2 kernel: [7305227.400608] ata1.00: irq_stat 0x40000008 Nov 23 02:05:41 h2 kernel: [7305227.400627] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:41 h2 kernel: [7305227.400649] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:41 h2 kernel: [7305227.400650] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:41 h2 kernel: [7305227.400716] ata1.00: status: { DRDY ERR } Nov 23 02:05:41 h2 kernel: [7305227.400734] ata1.00: error: { UNC } Nov 23 02:05:41 h2 kernel: [7305227.472432] ata1.00: configured for UDMA/133 From what I read so far, I am not sure if read errors mean that a hard drive is dying on me (no write errors so far). I've had hard drive errors in the past and those always had errors about failing to write to specific sectors in the logs. Not this time. Should I be replacing the drive? Could something else be causing the problem? I've scheduled a smartctl -t long test that will finish in a couple of hours. I hope this will give me some more info.

    Read the article

  • Raid superblock missing on single parition. Recovery needed!

    - by user171639
    Ok so I have a 2 TB raid 1 setup that has three partitions: sdc1: linux sdc2: swap sdc3: LVM for data However the LVM will no longer mount. So I thought that I would take the first drive, mount it in linux (ive done this b4), and reset the spare drive to copy the data. Normally I can mount a single drive for data recovery using: sudo su apt-get install mdadm lvm2 mdadm --assemble --scan modprobe dm-mod vgscan vgchange -ay c mount -o ro /dev/c/c /mnt Unfortunately, vgscan doesnot recognize the data partition. It appears as though the superblock on the first drive's data partition was erased while syncing with the second. So now I cannot mount that partition and the second drive is stuck in spare mode. Any ideas? Or a way to force mount the data partition just to copy the data? knoppix@Microknoppix:~$ sudo su root@Microknoppix:/home/knoppix# apt-get install mdadm lvm2 Reading package lists... Done Building dependency tree Reading state information... Done lvm2 is already the newest version. mdadm is already the newest version. 0 upgraded, 0 newly installed, 0 to remove and 551 not upgraded. root@Microknoppix:/home/knoppix# mdadm --assemble --scan mdadm: /dev/md/1 has been started with 1 drive (out of 2). mdadm: /dev/md/0 has been started with 1 drive (out of 2). root@Microknoppix:/home/knoppix# modprobe dm-mod root@Microknoppix:/home/knoppix# vgscan Reading all physical volumes. This may take a while... No volume groups found root@Microknoppix:/home/knoppix# cat /proc/mdstat Personalities : [raid1] md0 : active raid1 sdc1[2] 4193268 blocks super 1.2 [2/1] [U_] md1 : active raid1 sdc2[2] 524276 blocks super 1.2 [2/1] [U_] unused devices: <none> root@Microknoppix:/home/knoppix# mdadm -v --assemble --auto=yes /dev/md2 /dev/sdc3 mdadm: looking for devices for /dev/md2 mdadm: no recogniseable superblock on /dev/sdc3 mdadm: /dev/sdc3 has no superblock - assembly aborted root@Microknoppix:/home/knoppix# dumpe2fs /dev/md0 | grep -i superblock dumpe2fs 1.42.4 (12-Jun-2012) Primary superblock at 0, Group descriptors at 1-1 Backup superblock at 32768, Group descriptors at 32769-32769 Backup superblock at 98304, Group descriptors at 98305-98305 Backup superblock at 163840, Group descriptors at 163841-163841 Backup superblock at 229376, Group descriptors at 229377-229377 Backup superblock at 294912, Group descriptors at 294913-294913 Backup superblock at 819200, Group descriptors at 819201-819201 Backup superblock at 884736, Group descriptors at 884737-884737 root@Microknoppix:/home/knoppix# Notes: I can read the super block from the spare drive. I was gonna try and restore the superblock from one of the backups, but i dont know how or if this would work. I also heard creating a new array (mdadm --create) using the same parameters will not delete the data on the drive but i didnt want to risk it. Recommendations?

    Read the article

  • SAS Expanders vs Direct Attached (SAS)?

    - by jemmille
    I have a storage unit with 2 backplanes. One backplane holds 24 disks, one backplane holds 12 disks. Each backplane is independently connected to a SFF-8087 port (4 channel/12Gbit) to the raid card. Here is where my question really comes in. Can or how easily can a backplane be overloaded? All the disks in the machine are WD RE4 WD1003FBYX (black) drives that have average writes at 115MB/sec and average read of 125 MB/sec I know things would vary based on the raid or filesystem we put on top of that but it seems to be that a 24 disk backplane with only one SFF-8087 connector should be able to overload the bus to a point that might actually slow it down? Based on my math, if I had a RAID0 across all 24 disks and asked for a large file, I should, in theory should get 24*115 MB/sec wich translates to 22.08 GBit/sec of total throughput. Either I'm confused or this backplane is horribly designed, at least in a perfomance environment. I'm looking at switching to a model where each drive has it's own channel from the backplane (and new HBA's or raid card). EDIT: more details We have used both pure linux (centos), open solaris, software raid, hardware raid, EXT3/4, ZFS. Here are some examples using bonnie++ 4 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 194MB/s 19% 92MB/s 11% 200MB/s 8% 310/sec 194MB/s 19% 93MB/s 11% 201MB/s 8% 312/sec --------- ---- --------- ---- --------- ---- --------- 389MB/s 19% 186MB/s 11% 402MB/s 8% 311/sec 8 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 324MB/s 32% 164MB/s 19% 346MB/s 13% 466/sec 324MB/s 32% 164MB/s 19% 348MB/s 14% 465/sec --------- ---- --------- ---- --------- ---- --------- 648MB/s 32% 328MB/s 19% 694MB/s 13% 465/sec 12 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 377MB/s 38% 191MB/s 22% 429MB/s 17% 537/sec 376MB/s 38% 191MB/s 22% 427MB/s 17% 546/sec --------- ---- --------- ---- --------- ---- --------- 753MB/s 38% 382MB/s 22% 857MB/s 17% 541/sec Now 16 Disk RAID-0, it's gets interesting WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 359MB/s 34% 186MB/s 22% 407MB/s 18% 1397/sec 358MB/s 33% 186MB/s 22% 407MB/s 18% 1340/sec --------- ---- --------- ---- --------- ---- --------- 717MB/s 33% 373MB/s 22% 814MB/s 18% 1368/sec 20 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 371MB/s 37% 188MB/s 22% 450MB/s 19% 775/sec 370MB/s 37% 188MB/s 22% 447MB/s 19% 797/sec --------- ---- --------- ---- --------- ---- --------- 741MB/s 37% 376MB/s 22% 898MB/s 19% 786/sec 24 Disk RAID-1, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 347MB/s 34% 193MB/s 22% 447MB/s 19% 907/sec 347MB/s 34% 192MB/s 23% 446MB/s 19% 933/sec --------- ---- --------- ---- --------- ---- --------- 694MB/s 34% 386MB/s 22% 894MB/s 19% 920/sec 28 Disk RAID-0, ZFS 32 Disk RAID-0, ZFS 36 Disk RAID-0, ZFS More details: Here is the exact unit: http://www.supermicro.com/products/chassis/4U/847/SC847E1-R1400U.cfm

    Read the article

  • Old Hardware Specifications

    - by billswift
    Anyone know where I can get specs for old monitors and soho computers? I'm setting up some old computers as linux boxes and especially need monitor specs for setting X Window System parameters. Right now I need specs for a Packard Bell 1024S monitor.

    Read the article

  • Hardware issue: UI freezes and hard drive light goes solid several times per hour

    - by alchemical
    I have a workstation that has been acting up for the last few weeks. It currently has Windows Server 2008 R2 installed on it, and 2 HDD mirrored. A few times per hour the screen will freeze up, applications will say "not responding", sometimes the screen will turn a lighter shaded color--at the same time the HDD light is on solid. This lasts anywhere from 10 to about 50 seconds. Could this be something with one of the drives or the mechanism keeping the mirror in place? Any other ideas?

    Read the article

  • Looking for a software solution which acts like a hardware KVM

    - by Daisetsu
    I've seen programs like Synergy before which allow a keyboard and mouse to be used across multiple systems. Unfortunately Synergy treats both systems like they are the same thing (when you move the mouse too far to the right it jumps to the other computer, along with keyboard input). I only have 1 monitor so what I need to do here is have a quick way to view my other desktop that is easy to manage. Remote desktop is difficult because you have to take it out of fullscreen, then minimize it and then re-maximize it when you want to use it again. If there were a single button I could hit to switch to the other computer that would be optimal. Both computers are on the same lan.

    Read the article

  • Has the hardware in my modem gone bad?

    - by Tyler Scott
    I contacted CenturyLink about my modem recently and received useless and unrelated information. The problem seems to be that the modem will no longer save settings, the web interface is unusable except in internet explorer for some reason, and the modem keeps resetting. CenturyLink claimed it had to do with signal strength but I checked and it is currently between good and outstanding according to this. All of the lights remain green even when it starts acting up and I lose internet and shortly before it crashes and reboots. Does anyone have any idea what is going on or what I can do to fix it? (Asking CenturyLink again is obviously not going to help.) Update 1: Accessing the syslog from the web interface causes a crash. After it reboots, the log looks like as follows: 01/01/1970 12:01:29 AM Ethernet Ethernet client connected ,ip(192.168.0.2), mac(1c:6f:65:4c:6d:3b) 01/01/1970 12:01:38 AM Wireless 802.11 client connected ,ip(192.168.0.18), mac(d0:df:c7:c2:73:ca) 01/01/1970 12:01:41 AM System Event Line 0: VDSL2 link up, Bearer 0, us=20128, ds=40127 01/01/1970 12:01:43 AM dhcp6s[2028] dhcp6_ctl_authinit: failed to open /etc/dhcp6sctlkey: No such file or directory 01/01/1970 12:01:50 AM dhcp6s[2469] dhcp6_ctl_authinit: failed to open /etc/dhcp6sctlkey: No such file or directory 01/01/1970 12:01:52 AM radvd[2306] poll error: Interrupted system call 01/01/1970 12:01:56 AM PPP Link PPP server detected. 01/01/1970 12:01:56 AM PPP Link PPP session established. 01/01/1970 12:01:56 AM PPP Link PPP LCP UP. 01/01/1970 12:01:56 AM System Event Received valid IP address from server. Connection UP. 06/05/2014 08:16:01 AM radvd[2511] poll error: Interrupted system call 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:03 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:04 AM System Event Dead loop on virtual device tun6rd, fix it urgently! 06/05/2014 08:16:04 AM dhcp6s[3236] dhcp6_ctl_authinit: failed to open /etc/dhcp6sctlkey: No such file or directory 06/05/2014 08:16:08 AM Wireless 802.11 client connected ,ip(192.168.0.7), mac(44:6d:57:c4:d7:08) I also get it to crash on various other pages. I am guessing the web server is unstable.

    Read the article

  • Laptop hardware recommendations for multi-platform development

    - by iama
    I am thinking of buying a laptop with the following configuration - Intel core 2 duo(or I3-330M)/ 4GB RAM/300+ GB 7200 RPM. I would like to be able to run two server VMs on this laptop with Win2K8 and Ubuntu (preferably 64 bit editions). Windows 7 will be the Host OS since that is the one that ships with the laptop. I am thinking of using VMWare player to run the two server OSs. Is this laptop good enough to run the two VMs side by side or do I need to go for a better configuration? Any suggestions? Thanks.

    Read the article

  • Laptop hardware recommendations for multi-platform development

    - by iama
    I am thinking of buying a laptop with the following configuration - Intel core 2 duo(or I3-330M)/ 4GB RAM/300+ GB 7200 RPM. I would like to be able to run two server VMs on this laptop with Win2K8 and Ubuntu (preferably 64 bit editions). Windows 7 will be the Host OS since that is the one that ships with the laptop. I am thinking of using VMWare player to run the two server OSs. Is this laptop good enough to run the two VMs side by side or do I need to go for a better configuration? Any suggestions? Thanks.

    Read the article

  • hardware leasing vs purchase

    - by musoNic80
    I'm wanting to get a new laptop and desktop. I'm self-employed and so both bits of kit are primarily for business use. I've been looking into leasing both computers as an alternative to purchasing outright. Does anyone have any experience of this? I'm UK based and have found a company called hardsoft which seem to offer a good service. I'm particularly attracted by the upgrade after 18 months option and the fact that the machines are under warranty for the lift of the lease. I'd be really grateful for general thoughts, especially if there are any UK users or hardsoft clients.

    Read the article

  • Hardware profiling [closed]

    - by mgroves
    I'd like to upgrade my computer so that it's faster when editing/rendering video. I'm thinking of first getting a faster hard drive, but I'd like to be able to run some sort of profiling software to tell me what the bottleneck is when rendering video. Any suggestions about software that can do this for preferably Windows XP and preferably for free?

    Read the article

< Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >