Search Results

Search found 1380 results on 56 pages for 'nic young'.

Page 26/56 | < Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >

  • Virtual machines interconnection inside Proxmox 2.1 Cluster

    - by Anton
    We have 3 physical servers (each with 1 NIC) in different datacentres, all of them are interconnected by openvpn bridged private network (10.x.x.x). Inside this network we have fully functional 3 nodes Proxmox 2.1 cluster. So, actually question is: Is there any "proper" way to make "global" local network (172.16.x.x) for all VMs inside cluster, so even if we move VM from one node to other we could reach it by static IP regardless of it's physical location? BTW, we can't add dedicated NIC to each server. Thanks in advance. EDIT: I have tried to make a separate openvpn bridge for 172.16.x.x, now I have at each server two interfaces: SRV1: openvpnbr1 - 172.16.13.1 vmbr0 - 172.16.1.1 SRV2: openvpnbr1 - 172.16.13.2 vmbr0 - 172.16.2.1 But now there is no connection between those ifaces: SRV1: ping 172.16.13.2 From 172.16.1.1 icmp_seq=2 Destination Host Unreachable SRV2: ping 172.16.13.1 From 172.16.2.1 icmp_seq=2 Destination Host Unreachable If I shut down vmbr0 interfaces, so there is connection between servers over openvpn, but vmbr0 is used by Proxmox... Where I am wrong?

    Read the article

  • Network Misconfiguration when adding first host to new vSphere cluster

    - by dunxd
    I am building a new vSphere cluster from scratch. I have installed ESXi on the first host, and built a vCenter server on a VM residing on that host (storage is on the local hard drive, although we have iSCSI targets which I can reach from the host). The cluster is configured for HA. When I try and add the host to the cluster, I get an error at the point where HA is configured - Cannot complete the . I have stripped the network configuration of the host down to the most basic - a single NIC attached to a single vSwitch - this is running the VMKernel Port on VLAN 8 - that is our Management VLAN. The vCenter server will have a network address on this VLAN, so I also set the initial Virtual Machine Port Group to this VLAN, and connected the vCenter server NIC to this port group. I understand I can't connect the vCenter server to the VMkernel port group, but shouldn't I be able to connect the vCenter server to a Port Group in the same VLAN? If not, do I need to create a VLAN specifically for VMKernel Port Group? I plan to set up another port group for vMotion with a dedicated and isolated VLAN (i.e. VLAN isn't routed) so this wouldn't allow vCenter to communicate. Does anyone have any suggestions, or other ideas for what might be causing the problem. I've read through the documentation, but it isn't giving me any pointers, and the error message isn't helping me beyond telling me something is wrong with my network config.

    Read the article

  • Debian: Should I add vlan interface into bridge for KVM?

    - by javano
    I am setting up a Debian Squeeze box as a KVM host. I want to add multiple interfaces to each KVM guest so I want them to be on different VLANs. After reading about this, I believe the best method is to add multiple logical VLAN (sub)-interfaces to the physical NICs and then create a bridge adapter for each VLAN interace, and assign each bridge as a NIC for KVM guests. Does this make good sense, or madness? Do I have to use bridged interfaces with KVM like this? Can't I just add eth1.xx and eth1.yy to my interfaces config below and then configure those directly as bridged KVM guest NICs? If so, how should this look in the interfaces config file below? user@host:~$ cat /etc/network/interfaces # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # Management Interface auto eth0 iface eth0 inet static address 172.22.0.31 netmask 255.255.255.0 gateway 172.22.0.1 # Interface for guest VMs auto eth1 # Guest1 : Use VLAN 117 auto eth1.117 iface eth1.117 inet manual # Set up br1 for guest 1, bridging with vlan 117 auto br1.117 iface br1.117 inet manual bridge_ports eth1.117 bridge_stp off user@host:~$ uname -a Linux hostname 3.4.9 #1 SMP Wed Aug 22 19:08:46 BST 2012 x86_64 GNU/Linux UPDATE I would really like it if someone could clarify the config for me, as I have also seen the above configured with this syntax, so I don't see why one would be preferred over the other; # Interface for guest VMs auto eth1 allow-hotplug eth1 iface eth1 inet static # Vlan 117 for guest 1 auto vlan 117 iface vlan111 inet static vlan_raw_device eth1 # Guest 1 : NIC 1 auto br1.117 iface br1.117 inet manual bridge_ports vlan117 bridge_stp off

    Read the article

  • How to choose which network connection provides the default gateway in Windows XP

    - by Cathy
    I have a laptop with an integrated NIC and a WiFi connection. Both the wired and wireless networks I am using can access the Internet. Win XP is routing all traffic through the wireless network. I want to force it to route everything through the wired network when it is available (i.e. when I am sitting at my desk with the laptop docked) and through the wireless when that is the only option (i.e. when I have undocked my laptop and carried it to a conference room, or if I am out of the office working on a different WiFi network). The wireless connection cannot be established until after I am logged into Windows, so it's always the second network to become available to the OS. I have manually overridden the metric values in the TCP/IP configurations so that the NIC has metric 10 and the WiFi has metric 20. However, Windows is still picking the WiFi adapter's address as the Default Gateway, so this isn't helping. If I manually disable and re-enable the WiFi adapter, then it will switch the default gateway to the wired network and stay that way until I shutdown Windows. How can I tell Windows XP not to replace the default gateway when the WiFi connection is first enabled?

    Read the article

  • Performance monitoring on Linux/Unix

    - by ervingsb
    I run a few Windows servers and (Debian and Ubuntu) Linux and AIX servers. I would like to continously monitor performance on these systems in order to easily identify bottlenecks as well as to have an overview of the general activity on the servers. On Windows, I use Windows Performance Monitor (perfmon) for this. I set up these counters: For bottlenecks: Processor utilization : System\Processor Queue Length Memory utilization : Memory\Pages Input/Sec Disk Utilization : PhysicalDisk\Current Disk Queue Length\driveletter Network problems: Network Interface\Output Queue Length\nic name For general activity: Processor utilization : Processor\% Processor Time_Total Memory utilization : Process\Working Set_Total (or per specific process) Memory utilization : Memory\Available MBytes Disk Utilization : PhysicalDisk\Bytes/sec_Total (or per process) Network Utilization : Network Interface\Bytes Total/Sec\nic name (More information on the choice of these counters on: http://itcookbook.net/blog/windows-perfmon-top-ten-counters ) This works really well. It allows me to look in one place and identify most common bottlenecks. So my question is, how can I do something equivalent (or just very similar) on Linux servers? I have looked a bit on nmon (http://www.ibm.com/developerworks/aix/library/au-analyze_aix/) which is a free performance monitoring tool developed for AIX but also availble for Linux. However, I am not sure if nmon allows me to set up the above counters. Maybe it is because Linux and AIX does not allow monitoring these exact same measures. Is so, which ones should I choose and why? If nmon is not the tool to use for this, then what do you recommend?

    Read the article

  • How to fake ip at localhost without LoopBack.

    - by sexer
    How can i fake an ip on my own PC? for example if there were an ip address lets say 201.91.81.71, that Host is somewhere outside of my red and is hosting a webserver. How can set a website on my own PC, and when i go to browser and try to explore 201.91.81.71 it actually explore the website at my own PC? pd: I need it with IP addresses not domain names, since I need to implement it on a non-web service. First guess was installing a LoopBack with 201.191.81.71 as ip, but since some times the subnet works and some other it doesn't isn't a stable solution. Second guess was adding a route to route table : route add 201.91.81.71 mask 255.255.255.255 192.168.1.2 192.168.1.2 is the ip address of my NIC. If i could add this route it would work but windows doesn't let me do so. route add 201.91.81.71 mask 255.255.255.255 127.0.0.1 it doesn't let me set as gateway 127.0.0.1 if 201.91.81.71 isn't set in a NIC, so thats why i set sometimes loopback and this route add is auto, but it needs a subnet mask which doesn't match the ip and cannot set 255.255.255.255, im in real throubles here. can i get some help? thx.

    Read the article

  • Why is my connection slow?

    - by Jay R.
    I have a Dell Precision T5400 with a Broadcom 1Gb onboard NIC. For some strange reason, when I access machines on our local network, the best I can get is around 125KB/s download speed. My laptop that has a 10/100Mb NIC onboard usually gets around 300KB/s or better from the same network resource. Both machines are plugged into the same 1Gb switch which connects to our local network wall jack at 100Mb half duplex. There is also a printer plugged into the same switch at 100Mb full. The resource I'm using for the test is a 30MB zip file copied from a jetty webserver that is running as part of a cruisecontrol installation. The cruisecontrol installation is running WindowsXP with full real-time antivirus and Altiris patch management and inventory running. That stuff on its own is eating some of the download speed. I've seen the laptop reach into the multiple MB/s download speed before, but the desktop never seems to get past 125KB/s to 130KB/s. In WindowsXP, before I upgraded the driver in the desktop, it was that slow. In Fedora, it is still slow even though it appears to be using the same driver version as the upgraded Windows driver. The upgraded Windows driver is faster, but still not nearly as fast as the laptop. What gives? Any insight to improve the situation would be appreciated. Could it be that the BroadCom board just isn't that good, or the driver in linux is just not as good as the Windows one?

    Read the article

  • Is this a solution for having multiple SSL certificates on the same IP

    - by Saif Bechan
    I am running CentOS running on a VPS. I read some guides on having multiple SSL certificates on the same system, but I can not get the basics to work. The guide I got that makes the most sense to me is the doing the following. In CentOS I can make virtual NIC's. So I made 2 virtual NIC's to start with. 192.168.10.1, 192.168.10.2. Now I work in ISP manager Pro, so this is listening on my primary ip 1.1.1.1 For each website I have them listening on 192.168.10.1:80, 192.168.10.1:443 In the hosts file I made the following 2 entries 192.168.10.1 1st.com 192.168.10.2 2nd.com Now the strange thing is that when I browser to 1st.com I do not get the website located at 192.168.10.1, I get the website located at my prim IP 1.1.1.1 Should I do something like forwarding or routing for this setup to work? And the basic question: Will this setup even work? Are the SSL certificates based on the IP adress, or are the based on the host name, 1st.com and 2nd.com.

    Read the article

  • Network access lags for Win7 when server network utilization is high

    - by Jeff Miles
    We have a Dell PE2950 file server running Windows 2008, hosting a DFS namespace of ~1.2 TB. This server has two Broadcom 1Gbps NICs teamed together. When there is high traffic going to the server across the network (greater than 200 Mbps), any Windows 7 client accessing a DFS share at the time experiences severe performance problems. For example: Computer A has an AutoCAD drawing opened directly from the DFS share. Performance is normal, not causing any issues. Computer B begins a file transfer, putting a 11GB file onto a different DFS namespace, on the same server Computer A immediately notices lag while using AutoCAD. The cursor momentarily freezes within AutoCAD every 10 seconds or so, and any browsing of the DFS share is extremely slow. Computer B completes file transfer, and performance resumes to normal for Computer A. This is only affecting Windows 7 clients, using a variety of hardware (desktop + laptop). All of our Windows XP clients see no performance impact during the file transfer. Things I have tried with no change: Had Computer A work from an entirely different RAID array from the file transfer destination Updated NIC drivers on clients and server Enabled TCP offload and receive side scaling on the server NIC (previously disabled when the issue began) Antivirus disabled during file transfer I am currently having a user test applications other than AutoCAD when the file transfer occurs, and will update the question with that result. Does anyone have any recommendations for resolution or additional troubleshooting steps?

    Read the article

  • How important is dual-gigabit lan for a super user's home NAS?

    - by Andrew
    Long story short: I'm building my own home server based on Ubuntu with 4 drives in RAID 10. Its primary purpose will be NAS and backup. Would I be making a terrible mistake by building a NAS Server with a single Gigabit NIC? Long story long: I know the absolute max I can get out of a single Gigabit port is 125MB/s, and I want this NAS to be able to handle up to 6 computers accessing files simultaneously, with up to two of them streaming video. With Ubuntu NIC-bonding and the performance of RAID 10, I can theoretically double my throughput and achieve 250MB/s (ok, not really, but it would be faster). The drives have an average read throughput of 83.87MB/s according to Tom's Hardware. The unit itself will be based on the Chenbro ES34069-BK-180 case. With my current hardware choices, it'll have this motherboard with a Core i3 CPU and 8GB of RAM. Overkill, I know, but this server will be doing other things as well (like transcoding video). Unfortunately, the only Mini-ITX boards I can find with dual-gigabit and 6 SATA ports are Intel Atom-based, and I need more processing power than an Atom has to offer. I would love to find a board with 6 SATA ports and two Gigabit LAN ports that supports a Core i3 CPU. So far, my search has come up empty. Thus, my dilemma. Should I hold out for such a board, go with an Atom-based solution, or stick with my current single-gigabit configuration? I know there are consumer NAS units with just one gigabit interface (probably most of them), but I think I will demand a lot more from my server than the average home user. Any advice is appreciated. Thanks.

    Read the article

  • Monitor mode 802.11 captures on OSX

    - by Mike A
    I'm trying to determine the difference between capturing 802.11 frames in the following ways on OSX (10.8.5). It's a bit esoteric, but I use "Option 2" to capture frames for later analysis, and am wondering if I'm missing something. Option 1: use "airportd": $sudo /usr/libexec/airportd en0 sniff Option 2: use "airport" followed by tcpdump: sudo /System/Library/PrivateFrameworks/Apple80211.framework/Versions/Current/Resources/airport --channel= sudo tcpdump -I -P -i en0 -w /tmp/capture.pcap (or alternatvely eliminate the -w and watch packets real-time). From what I can tell: Both commands, according to the wifi icon on OSX, put the interface into 'monitor' mode. Both commands output a pcap file that is readable in both wireshark/tcpdump & Eye PA. Both commands appear to capture management, control and data frames. The rub: Option 1 disconnects you from the network. This is expected, when putting an interface into 'monitor' mode. Option 2 does NOT disconnect you, provided you've set the channel to the same channel your currently connected to. This has a distinct advantage of keeping your connection up while capturing in monitor mode. My question: Option 2 does not seem like it should work, or more specifically, it does not seem like I should be able to remain connected while also capturing frames in monitor mode. On a wired NIC, you can be 'promiscuous' and still send frames, though I didn't think the same was true for wireless NIC. I'm questioning the validity of capturing frames w/ Option 2?

    Read the article

  • Weirdly high ping on direct ethernet connection?

    - by Antriel
    I bought new Lenovo IdeaCentre H430 pc and I'm having problem with high pings. Windows 7 with on-board realtek NIC. Fresh install, fully updated, drivers installed from included CD. When I start pinging router (direct 1Gb ethernet connection, 1 hop), pings start at <1ms (which is fine) and after a while they jump to 300-1000ms. I loaded up live ubuntu to test if the problem might be in HW. It's not, in ubuntu pings were always <1ms. I also noticed that when I start using connection somehow, pings go down to 1ms, but go back up when I stop using it (tested by accessing live camera feed on LAN). Power Options set to max performance. I disabled Interrupt Moderation on the NIC, didn't help. I tested it in the safe mode with networking, same problem there. It slows down our client-server based programs and I have no idea what's causing it. All I could google up was that disabling Interrupt Moderation would help, it didn't though. Anyone had similar problems? tl;nr: Computer is giving high pings to router when idle and normal pings when network is under load, it slows down our software significantly.

    Read the article

  • VLAN for WiFi traffic separation (new to VLANing)

    - by Philip
    I run a school network with switches in different departments. All is routed through to a central switch to access the servers. I would like to install WiFi access points in the different departments and have this routed through the firewall (an Untangle box that can captive-portal the traffic, to provide authentication) before it gets onto the LAN or to the Internet. I know that the ports that the APs connect to on the relevant switches need to be set to a different VLAN. My question is how do I configure these ports. Which are tagged? Which are untagged? I obviously don't want to interrupt normal network traffic. Am I correct in saying: The majority of the ports should be UNTAGGED VLAN 1? Those that have WiFi APs attached should be UNTAGGED VLAN 2 (only) The uplinks to the central switch should be TAGGED VLAN 1 and TAGGED VLAN 2 The central switch's incoming ports from the outlying switches should also be TAGGED VLAN 1 and TAGGED VLAN 2 There will be two links to the firewall (each on its own NIC), one UNTAGGED VLAN 1 (for normal internet access traffic) and one UNTAGGED VLAN 2 (for captive portal authentication). This does mean that all wireless traffic will be routed over a single NIC which will also up the workload for the firewall. At this stage, I'm not concerned about that load.

    Read the article

  • esx5 debian VM vlan setup

    - by Kstro21
    i have a server with ESX5, have a switch with about 20 vlans, this is how setup the trunk port interface GigabitEthernet0/1/1 description ToOper port link-type trunk undo port trunk allow-pass vlan 1 port trunk allow-pass vlan 2 to 14 stp disable ntdp enable ndp enable bpdu enable then, i created a standar switch(sw1) using the vSphere Client, the VLAN ID is set to All (4095), i also created a VM with Debian 6, with a NIC connected to sw1, now, i want to configure this NIC for a selected group of vlans auto vlan10 iface vlan10 inet static address 11.10.1.0 netmask 255.255.255.224 mtu 1500 vlan_raw_device eth0 auto vlan14 iface vlan14 inet static address 11.10.1.65 netmask 255.255.255.248 mtu 1500 vlan_raw_device eth0 so, when i restart the network using /etc/init.d/networking restart, i got this error Reconfiguring network interfaces...SIOCSIFADDR: No such device vlan14: ERROR while getting interface flags: No such device SIOCSIFNETMASK: No such device SIOCSIFBRDADDR: No such device vlan14: ERROR while getting interface flags: No such device SIOCSIFMTU: No such device vlan14: ERROR while getting interface flags: No such device Failed to bring up vlan14. done. this is just part of the error, so, my questions is: is this possible?, i mean, what i'm trying to achieve using ESX Virtual Machines, VLANS, etc is this a Debian problem? can be solved? i've read about a file named z25_persistent-net.rules in Debian but it doesn't exist in my installation. in the In the vSphere Networking for ESX5 guide, you can read: If you enter 0 or leave the option blank, the port group can see only untagged (non-VLAN) traffic. If you enter 4095, the port group can see traffic on any VLAN while leaving the VLAN tags intact. So, in theory, it should work, right? Hope you can help me up with this one Thanks

    Read the article

  • Gigabit LAN not working on ASUS M2N-MX

    - by chmod
    Today I replace my FastEthernet switch with a newly bought gigabit switch (DGS-1008A). All computers in my house are displaying that the connection speed is 1 Gbps except for one. The computer that is not working is an ASUS M2N-MX which contain an onboard gigabit NIC. See ASUS link for confirmation http://www.asus.com/Motherboards/AMD_AM2/M2NMX/ Here are some info of the machine OS: Windows 7 Ultimate SP1 64bit BIOS version: 1004 (latest) Driver: installed via Windows update (latest from Windows update) Windows Update: fully updated The machine is reformatted 3 days ago, so it's pretty clean, no junk, no virus, etc Cable: Amp CAT5E 5 meters In device manager, the name of the NIC is "NVIDIA nForce 10/100/1000 Mbps Ethernet" What I have try: I did try to install the driver provided in ASUS website, but there isn't any for Windows 7 64 or Vista 64. I did try to install the latest nForce340/6100, downloaded from Nvidia website. However, the LAN driver refuse to install, it complain that I already have the best driver installed. I looking in the property -- advance tab -- Speed/duplex settings, in an attempt to force it to run at 1000Mbps, but there is no 1000Mbps choice, only 10 and 100Mpbs. I change the CAT5E cable (use one from another computer that is running gigabit without problem) Anyone have this issue or know how to solve it? Thanks

    Read the article

  • Remote Desktop fails after VPN connection

    - by Samet Sorgut
    The local computer (comp 1) is connected to a remote computer (comp 2) with Remote Desktop. On the remote computer (comp 2), I try to establish an VPN connection to a different remote computer (comp 3). Once I try to establish the VPN connection from the remote computer (comp 2) to the second remote computer (comp 3), Remote Desktop freezes on comp 1. It is not possible to connect to comp 2 again via Remote Desktop. What can be done to connect to this remote computer (comp 2) after it establishes a VPN connection? The only thing that comes to my mind is to install a second NIC and configure Remote Desktop to accept connection from this NIC while VPN is working from the other... What do you suggest? EDIT: I want to use the internet connection of the VPN, so all traffic should go over the VPN but still RDP working. My IP: 100.0.0.1 The IP where I'm connecting via RDP: 200.0.0.20 (Mask: 255.255.255.192, Gateway: 200.0.0.193) Where the 200.0.0.1 connects to VPN the IP of the VPN is: 65.254.61.250 Will routing like this help (Command is issued in 200.0.0.20, the RDP location): route ADD 65.254.61.250 MASK 255.255.255.192 200.0.0.193 Couldn't add gives the error: The route addition failed: The parameter is incorrect. I tried before connecting to VPN.

    Read the article

  • sbs-server with 2 nics and 2 connections to the internet with different providers not working as it

    - by erik-van-gorp
    We have the following configuration : A sbs-2003 server in a domain (mydomain.com) with 2 network cards, each connected to a different network (provider), with different gateways, one for web and one for mail and clients. (we do this because the bandwitdh we get from our providers is too small to handle all the mail(+spam) traffic and webservices, so we took 2 providers) DNS is as follows : www.mydomain.com 1.2.3.4 mail.mydomain.com 5.6.7.8 NIC 1(192.168.1.3) is connected to to the internet through a firewall at 192.168.1.1, having wan address 1.2.3.4 NIC 2(10.0.0.3) is connected to to the internet through a firewall at 10.0.0.1, having wan address 5.6.7.8 Both nics have their default gateway installed at their corresponding routers. Also the metrics are set equal. (i know this isn't a supported config, but it works more or less). In this configuration i can use RDP on both wan adresses, and telnet to port 25 works as well on both. The issue now is that since a few weeks , we get regular disconnections, and website hickups(timeouts), several per hour. If we set one router to a higher metric, that route no longer works. In short, I want the mails to route through NIC2 and the web through NIC1. Any better configuration (without installing a second mail server) ?

    Read the article

  • Unable to set initcwnd on a Hetzner server

    - by Sergi
    We just ordered a bunch of Hetzner EX40SSD servers with the minimal Debian install image that they provide and everything is just fine except that looking at tcpdumps for fine tuning the network from various locations the initcwnd param seems to be stuck at 6 no matter how we change it. By default Debian 3.2 kernels should have that setting to 10 so it's pretty strange. Is it possible that the NIC driver or a custom setting in the Hetzner Debian image is limiting this param? Even if we set it to 4, like the old kernel default, it doesn't work. Any ideas would be much appreciated! Does anyone know if the NIC drivers provided by default by Debian have some kind on limitation. In a long thread in http://www.webhostingtalk.com/showthread.php?t=1200617&highlight=hetzner they talk about a page http://wiki.hetzner.de/index.php/Installation_des_r8168-Treibers/en where Hetzner states that the included Realtek r8168 driver is not working properly, but nowhere do they say that the initcwnd could be affected. Tomorrow i will try to install a CentOs image and see if Debian is the problem...Last resort would be to install a custom debian image, but that is a pain in the ass! Thanks!

    Read the article

  • xen + debian network after upgrade squeeze to wheeze

    - by rush
    I've got a Debian + Xen server. After a system upgrade to the stable version the network doesn't come up after boot. Every time after reboot I need to bring it up manually. The network configuration was not changed during upgrade. Here is /etc/network/interfaces: auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 11.22.33.44 netmask 255.255.255.0 gateway 11.22.33.1 nameserver 8.8.8.8 After boot ip r shows no route and eth0 has no ip address. Manually ip and route setup goes fine and network starts working. Messages from dmesg about network I've found (looks like nothing interesting) [ 3.894401] ACPI: Fan [FAN3] (off) [ 3.894444] ACPI: Fan [FAN4] (off) [ 4.178348] e1000e 0000:00:19.0: eth0: (PCI Express:2.5GT/s:Width x1) 00:1e:67:14:66:c9 [ 4.178351] e1000e 0000:00:19.0: eth0: Intel(R) PRO/1000 Network Connection [ 4.178392] e1000e 0000:00:19.0: eth0: MAC: 10, PHY: 11, PBA No: 0100FF-0FF [ 4.178413] e1000e 0000:02:00.0: Disabling ASPM L0s L1 [ 4.178432] xen: registering gsi 16 triggering 0 polarity 1 -- [ 4.223667] ata5: DUMMY [ 4.223668] ata6: DUMMY [ 4.289153] e1000e 0000:02:00.0: eth1: (PCI Express:2.5GT/s:Width x1) 00:1e:67:14:66:c8 [ 4.289155] e1000e 0000:02:00.0: eth1: Intel(R) PRO/1000 Network Connection [ 4.289245] e1000e 0000:02:00.0: eth1: MAC: 3, PHY: 8, PBA No: 1000FF-0FF [ 4.506908] usb 1-1: new high-speed USB device number 2 using ehci_hcd [ 4.542920] ata2: SATA link up 3.0 Gbps (SStatus 123 SControl 300) -- [ 10.362999] EXT4-fs (dm-23): mounted filesystem with ordered data mode. Opts: (null) [ 10.419103] EXT4-fs (dm-3): mounted filesystem with ordered data mode. Opts: (null) [ 10.988255] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 13.175533] Event-channel device installed. [ 13.287555] XENBUS: Unable to read cpu state -- [ 13.288670] XENBUS: Unable to read cpu state [ 13.965939] Bridge firewalling registered [ 14.134048] e1000e: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 14.283862] ADDRCONF(NETDEV_UP): peth0: link is not ready [ 14.284543] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 17.800627] e1000e: peth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 17.801377] ADDRCONF(NETDEV_CHANGE): peth0: link becomes ready [ 18.307278] device peth0 entered promiscuous mode [ 24.538899] eth1: no IPv6 routers present [ 28.570902] peth0: no IPv6 routers present I've upgraded two servers and I've such behaviour on two of them. How to fix this and get network starts automatically on boot?

    Read the article

  • SSH agent forwarding on debian squeeze

    - by nfvindaloo
    Im trying to set up SSH forwarding like this osx debianA debianB I can connect to debianA fine, using ssh -A and it has the following env vars when i do: SSH_AGENT_PID=1543 SSH_AUTH_SOCK=/tmp/ssh-giwdYY1542/agent.1542 SSH_CLIENT='92.233.199.x 38954 22' SSH_CONNECTION='92.233.199.x 38954 108.171.179.x 22' SSH_TTY=/dev/pts/0 When i try to connect to debianB, the agent is not used! ssh -v output ends with: debug1: SSH2_MSG_SERVICE_REQUEST sent debug1: SSH2_MSG_SERVICE_ACCEPT received debug1: Authentications that can continue: publickey,password debug1: Next authentication method: publickey debug1: Trying private key: /home/nic/.ssh/id_rsa debug1: Trying private key: /home/nic/.ssh/id_dsa debug1: Next authentication method: password Then im asked for a password. I have not set any ForwardAgent no directives in ssh_config and dont have a .ssh/config at all. sshd_config has not got AllowAgentForwarding in it. I have tried all of these directives as yes also. debianA and debianB both have identical ssh_config and sshd_config (verified with diff) so the really weird thing is connecting OSX debianB debianA works fine!! Im totally out of ideas! Has anyone come across this before? Cheers! NFV

    Read the article

  • Windows-7 Ultimate 64 bit wont connect to my wired/wireless networks.

    - by A302
    Windows 7 Ultimate 64 bit. Everything was working fine & then just stopped working. The nic card Realtek PCIe GBE Family Controller is enabled but does not connect to my router (cables & router ports are good). Wireless Atheros AR5007EG is enabled but the connection is limited (encryption type / key have been verified). A laptop running XP can connect both wired / wireless. SSID is not being broadcast, connect to network if it is not broadcasting is checked. Have checked services.msc for Bonjour & did not see it listed. Network & sharing center does not list any active networks. Device manager lists both devices as functioning properly. Router configuration has not been changed. Virus scan has not found anything. I would like to fix this rather than using Acronis to do a system restore. Thanks in advance for any advice offered in solving this. 26 Jan, the nic card & wireless are working using PCLinux OS Live CD. It appears that the problem is Windows 7 related.

    Read the article

  • How to automatically start VM created by virt-manager?

    - by Jeff Shattock
    I have created a virtual machine with virt-manager that runs on kvm/qemu. The machine works well when started through virt-manager. However, I would like to be able to start and stop the VM through a script in init.d, so that it comes up and down along with the host. I need to have virt-manager show that the machine is running, and to be able to connect to its console through there. When I use the command line that is produced by running ps -eaf | grep kvm after starting the vm through virt-manager, I get some console messages about redirected character devices, but the machine does start and runs properly. However, I do not get any indication from virt-manager that it has started. How can I modify the command line to get virt-manager to pick up the running VM? Is there anything else about the command line that should change when starting outside of virt-manager? Command line is (slightly reformatted for readability): /usr/bin/kvm -S -M pc-0.12 -enable-kvm -m 512 -smp 1 -name BORON \ -uuid fa7e5fbd-7d8e-43c4-ebd9-1504a4383eb1 \ -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/BORON.monitor,server,nowait \ -monitor chardev:monitor -localtime -boot c \ -drive file=/dev/FS1/BORON,if=ide,index=0,boot=on,format=raw \ -net nic,macaddr=52:54:00:20:0b:fd,vlan=0,name=nic.0 \ -net tap,fd=41,vlan=0,name=tap.0 -chardev pty,id=serial0 -serial chardev:serial0 \ -parallel none -usb -usbdevice tablet -vnc 127.0.0.1:1 -k en-us -vga cirrus

    Read the article

  • securing communication between 2 Linux servers on local network for ports only they need access to

    - by gkdsp
    I have two Linux servers connected to each other via a cross-connect cable, forming a local network. One of the servers presents a DMZ for the other server (e.g. database server) that must be very secure. I'm restricting this question to communication between the two servers for ports that only need to be available to these servers (and no one else). Thus, communication between the two servers can be established by: (1) opening the required port(s) on both servers, and authenticating according to the applications' rules. (2) disabling IP Tables associated with the NIC cards the cross-connect cable is attached to (on both servers). Which method is more secure? In the first case, the needed ports are open to the external world, but protected by user name and password. In the second case, none of the needed ports are open to the outside world, but since the IP Tables are disabled for the NIC cards associated with the cross-connect cables, essentially all of the ports may be considered to be "open" between the two servers (and so if the server creating the DMZ is compromized, the hacker on the DMZ server could view all ports open using the cross-connect cable). Any conventional wisdom how to make the communication secure between two servers for ports only these servers need access to?

    Read the article

  • Windows-7 Ultimate 64 bit wont connect to my wired/wireless networks

    - by A302
    Windows 7 Ultimate 64 bit. Everything was working fine & then just stopped working. The nic card Realtek PCIe GBE Family Controller is enabled but does not connect to my router (cables & router ports are good). Wireless Atheros AR5007EG is enabled but the connection is limited (encryption type / key have been verified). A laptop running XP can connect both wired / wireless. SSID is not being broadcast, connect to network if it is not broadcasting is checked. Have checked services.msc for Bonjour & did not see it listed. Network & sharing center does not list any active networks. Device manager lists both devices as functioning properly. Router configuration has not been changed. Virus scan has not found anything. I would like to fix this rather than using Acronis to do a system restore. Thanks in advance for any advice offered in solving this. 26 Jan, the nic card & wireless are working using PCLinux OS Live CD. It appears that the problem is Windows 7 related.

    Read the article

  • vmware server 64 bit on ubuntu 9.10 64 bit with P2V windows 2003 SBS poor network speed

    - by RobertHC
    configuration is ubuntu 2.6.31-21 64 bit vmware 2.0.2 64 bit last release hardware is core 2 quad with 8GB ram guest is win 2003 server SBS 32 bit Dear friends, we have a converted physical to virtual windows sbs 2003, converted with last converter available nowadays http://www.vmware.com/products/converter/ vCenter converter. Running the P2V 2K3 SBS on vmware server, it does boot fine, but we do note an abnormal CPU activity and a poor lan speed. As attempts we did what follow. We removed all unneeded peripherals, we removed one NIC (phisycal server was 2 nics), we changed the vmx to ged the nic recognized as intel instead than amd, we removed 1 cpu (physical was 2 cpu), we removed anything was reported as failed driver from system events monitor. Nothing to do, no way and funny results. Let's read some tests results. All are made with the same file copied in different source folders. Copying from client side (both directions copy, to/from server) results are i.e. 10 seconds, copying the same files from server side (again from and to server) results are different... from client to server, speed is round about (bit more) 10 seconds, but from server to client direction is slower: double the time. Beeing very fast and launching a simultaneous copy "from server to client"+"from client to server", this made from the server side, results in a stuck traffic... 45 seconds to do the copy. vmware tools are installed and e1000 driver has been updated. With one processor CPU activity is still going up and down but much less than with two. Because of test, we installed win 2k8 STD 64 bit. We repeated all the above tests with exactly the same file result is just one: always 5 seconds (this matches the lan speed) Any idea about this issue is welcome and thank you if any. Kind regards R.

    Read the article

< Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >