Search Results

Search found 6392 results on 256 pages for 'reduce duplicate'.

Page 26/256 | < Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Need help figuring out scala compiler errors.

    - by klactose
    Hello all, I have been working on a project in scala, but I am getting some error messages that I don't quite understand. The classes that I am working with are relatively simple. For example: abstract class Shape case class Point(x: Int, y: Int) extends Shape case class Polygon(points: Point*) extends Shape Now suppose that I create a Polygon: val poly = new Polygon(new Point(2,5), new Point(7,0), new Point(3,1)) Then if I attempt to determine the location and size of the smallest possible rectangle that could contain the polygon, I get various errors that I don't quite understand. Below are snippets of different attempts and the corresponding error messages that they produce. val upperLeftX = poly.points.reduceLeft(Math.min(_.x, _.x)) Gives the error: "missing parameter type for expanded function ((x$1) = x$1.x)" val upperLeftX = poly.points.reduceLeft((a: Point, b: Point) => (Math.min(a.x, b.x))) Gives this error: "type mismatch; found : (Point, Point) = Int required: (Any, Point) = Any" I am very confused about both of these error messages. If anyone could explain more clearly what I am doing incorrectly, I would really appreciate it. Yes, I see that the second error says that I need type "Any" but I don't understand exactly how to implement a change that would work as I need it. Obviously simply changing "a: Point" to "a: Any" is not a viable solution, so what am I missing?

    Read the article

  • Delete duplicate records from a SQL table without a primary key

    - by Shyju
    I have the below table with the below records in it create table employee ( EmpId number, EmpName varchar2(10), EmpSSN varchar2(11) ); insert into employee values(1, 'Jack', '555-55-5555'); insert into employee values (2, 'Joe', '555-56-5555'); insert into employee values (3, 'Fred', '555-57-5555'); insert into employee values (4, 'Mike', '555-58-5555'); insert into employee values (5, 'Cathy', '555-59-5555'); insert into employee values (6, 'Lisa', '555-70-5555'); insert into employee values (1, 'Jack', '555-55-5555'); insert into employee values (4, 'Mike', '555-58-5555'); insert into employee values (5, 'Cathy', '555-59-5555'); insert into employee values (6 ,'Lisa', '555-70-5555'); insert into employee values (5, 'Cathy', '555-59-5555'); insert into employee values (6, 'Lisa', '555-70-5555'); I dont have any primary key in this table .But i have the above records in my table already. I want to remove the duplicate records which has the same value in EmpId and EmpSSN fields. Ex : Emp id 5 Can any one help me to frame a query to delete those duplicate records Thanks in advance

    Read the article

  • Duplicate a collection of entities and persist in Hibernate/JPA

    - by Michael Bavin
    Hi, I want to duplicate a collection of entities in my database. I retreive the collection with: CategoryHistory chNew = new CategoryHistory(); CategoryHistory chLast = (CategoryHistory)em.createQuery("SELECT ch from CategoryHistory ch WHERE ch.date = MAX(date)").getSingleResult; List<Category> categories = chLast.getCategories(); chNew.addCategories(categories)// Should be a copy of the categories: OneToMany Now i want to duplicate a list of 'categories' and persist it with EntityManager. I'm using JPA/Hibernate. UPDATE After knowing how to detach my entities, i need to know what to detach: current code: CategoryHistory chLast = (CategoryHistory)em.createQuery("SELECT ch from CategoryHistory ch WHERE ch.date=(SELECT MAX(date) from CategoryHistory)").getSingleResult(); Set<Category> categories =chLast.getCategories(); //detach org.hibernate.Session session = ((org.hibernate.ejb.EntityManagerImpl) em.getDelegate()).getSession(); session.evict(chLast);//detaches also its child-entities? //set the realations chNew.setCategories(categories); for (Category category : categories) { category.setCategoryHistory(chNew); } //set now create date chNew.setDate(Calendar.getInstance().getTime()); //persist em.persist(chNew); This throws a failed to lazily initialize a collection of role: entities.CategoryHistory.categories, no session or session was closed exception. I think he wants to lazy load the categories again, as i have them detached. What should i do now?

    Read the article

  • Exporting from SSRS 2008 ReportViewer to Excel Causes Duplicate Columns

    - by Daniel Coffman
    I have a report that groups months by quarters, so each quarter has three months and the display of the months under the quarter is toggled by the quarter header. It looks just fine in the ReportViewer, but when exporting to Excel the first month in the quarter with data is duplicated and appended to the end of the quarter group. Here is what it looks like in the ReportViewer (with Quarters 2 and 4 expanded, note May and June do not have any data and show blank columns by design): http://i.imgur.com/MykZE.png This is how it looks when exported to Excel: http://i.imgur.com/zfLuk.png The collapsed Quarter should only show the LAST month in the quarter. You can see that in the Excel export July is inserted in Q1 even though it should be hidden entirely since that quarter is collapsed, December is appended to Q2, January is inserted into Q3, and April is duplicated and appended to Q4. Exporting the any format OTHER than Excel works correctly and does not insert these columns. A similar bug for rows was filed and marked as "by design": http://connect.microsoft.com/SQLServer/feedback/details/508823/reporting-services-2008-group-by-export-to-excel-duplicate-rows-csv-ok-pdf-ok How do I stop the export to Excel feature from inserting these duplicate columns?

    Read the article

  • Xcode - duplicate Target - new Target fails to build

    - by SirRatty
    Hi all, using Xcode 3.2.5 on 10.6.6 (10J521) I have an Xcode project containing 1 Target: "MyApp". It builds and runs successfully. As well as source and resource files, the Target contains a "Copy Files" build phase which copies "Sparkle.framework" in. The framework is in the same directory as the project. I want to duplicate this Target. Steps taken: Did "Clean all Targets". Right-clicked on the "MyApp" Target within Xcode, and then chose "Duplicate". Renamed the duplicated target to "MyAppTarget2". Selected "MyAppTarget2" as the Active Target from the popup menu in the top-left. Did "Build". The problem: error: Sparkle/Sparkle.h: No such file or directory This is puzzling! Each Build step appears to have been replicated in the duplicated Target, including the "Copy Files" phase. The Sparkle.framework exists at the path indicated by [Get Info on the Copy Phase item]. If I right-click on the Sparkle.framework file within the "Copy Files" build phase of the duplicated Target, and select "Reveal in Finder", then the correct Sparkle.framework file is shown. The required file exists at Sparkle.framework/Headers/Sparkle.h If I switch back to the original "MyApp" target, it builds and runs successfully. Am I doing something obviously wrong here? Thanks.

    Read the article

  • Upgraded to Xcode 4 -- Endless stream of duplicate symbol errors causing build errors

    - by D-Nice
    Everything was working perfectly fine in Xcode 3 yesterday before I upgraded. So I completed the upgrade, restarted my computer, and opened my old project. I had to reconfigure a few settings like the header paths so that I could begin to compile. I'm using AdWhirl for ad mediation, and at this point my errors begin to read something like duplicate symbol _OBJC_METACLASS_$_SBJSON in /Users/Admin/Desktop/TMapLiteAdwhirl/AdWhirl/MMSDK/libMMSDK.a(SBJSON.o) and /Users/Admin/Library/Developer/Xcode/DerivedData/TruxMapLite-bgpylibztethnlhkfkdumpvrjvgy/Build/Intermediates/TruxMapLite.build/Debug-iphoneos/TruxMapLite.build/Objects-normal/armv6/SBJSON.o for architecture armv6 The library it's referring to is the SDK for one of the ad networks I'm including in AdWhirl. Both of the 'duplicate symbols' refer to the SAME FILE, but they use different paths. If I had still had XCode 3, I would simply try excluding these libraries from the build path, but I have no idea how that can be done in Xcode 4. I've tried everything all the way down to deleting the library and all associated files from my project, but when I do this, i will simply get the same type of error for a different library in the AdWhirl directory. This is incredibly frustrating because before my upgrade everything was working smoothly and I was prepared to submit my binary. If anyone has any advice, id be more than happy to give it a try. Thanks!

    Read the article

  • Use MySQL trigger to update another table when duplicate key found

    - by Jason
    Been scratching my head on this one, hoping one of you kind people and direct me towards solving this problem. I have a mysql table of customers, it contains a lot of data, but for the purpose of this question, we only need to worry about 4 columns 'ID', 'Firstname', 'Lastname', 'Postcode' Problem is, the table contains a lot of duplicated customers. A new table is being created where each customer is unique and for us, we decide a unique customer is based on 'Firstname', 'Lastname' and 'Postcode' However, (this is the important bit) we need to ensure each new "unique" customer record also can be matched to the original multiple entries of that customer in the original table. I believe the best way to do this is to have a third table, that has 'NewUniqueID', 'OldCustomerID'. So we can search this table for 'NewUniqueID' = '123' and it would return multiple 'OldCustomerID' values where appropriate. I am hoping to make this work using a trigger and the on duplicate key syntax. So what would happen is as follows: An query is run taking the old customer table and inserting it in to the new unique table. (A standard Insert Select query) On duplicate key continue adding records, but add one entry in to the third table noting the 'NewUniqueID' that duped along with the 'OldCustomerID' of the record we were trying to insert. Hope this makes sense, my apologies if it isn't clear. I welcome and appreciate any thoughts on this one! Many thanks Jason

    Read the article

  • Removing duplicate images (deduplication) - calculating "overlap" of images

    - by jotango
    Hello, I have a ton of product images on our file system. Our code removes 100% identical images (or does not allow them to be uploaded). However our sellers often upload items pictures which are very similar, but not exactly. They could have more whitespace, a worse quality (compression), a different size etc. Is there any way I can calculate the degree of overlap between two images, to flag ones for deletion? Kind of like a Levenshtein distance between two images... Any pointers would be very cool. Thanks!

    Read the article

  • Configuring RAID1 on HP Proliant Microserver N54L / Ubuntu 14.04.1 LTS [duplicate]

    - by Chris Beach
    This question already has an answer here: Cant find my harddrives in ubuntu installation? 2 answers I've bought a N54L and fitted two 3GB drives. Keen to get set up with RAID1. BIOS: SATA controller mode set to "RAID" RAID Option ROM utility: both physical drives set up as one logical drive When I came to install Ubuntu (14.04.1), both drives appeared during the setup process. I was only expecting to see the logical drive, although I'm a complete novice with RAID. I've read that the HP Proliant Microservers don't have "proper" RAID support, and require some kind of driver to be installed. I've tried a few HP utilities from the following apt repo: deb http://downloads.linux.hp.com/SDR/repo/mcp wheezy/current non-free On installation, most say "server not supported" Would appreciate your advice.

    Read the article

  • Linux accessibility: Slow Keys causing duplicate key strokes

    - by skypanther
    I'm exploring the accessibility features within Gnome and having trouble with Slow Keys. My input is always doubled. Press a key briefly and I get nothing as you'd expect. Press just a bit longer and which ever key I'm pressing is input twice. Hello becomes HHeelllloo. I'm running Debian Lenny 5.0.6, kernel 2.6.26-2-686, GNOME Desktop 2.22.3 running within a VirtualBox session. I did some googling and didn't find others having similar troubles. Maybe it's a vbox thing? Any ideas how to fix this so I don't get the duplicates? It makes it impossible to log back in when the screen lock kicks on!

    Read the article

  • Duplicate of Certificate Templates does not appear in Certificate Template to Issue

    - by Sean
    I'm following what should be simple instructions to enable LDAP SSL on our domain controller (instructions here). Duplicating the Kerberos certificate is successful however, when attempting to select "Certificate Template to Issue", the created certificate does not appear. What gives? A long time ago, I actually completed this step on a now decommissioned DC with no problem. Our environment is Windows Server 2008 Standard, and we have two domain controllers. Only one has the role of certificate authority. I look forward to any help here, thank you ahead of time.

    Read the article

  • Is there a diff utility that allows you to exclude columns?

    - by user39160
    For example, I have a text file, each line is a long string. I want to exclude 2 "segments" of this string, say columns 1-7 and 20-22. So the bottom 2 lines below would be a match: 123456789012345678901234567890 ------------------------------ xxxxxxxAAAAAAAAAAAAxxxBBBBBBBB yyyyyyyAAAAAAAAAAAAyyyBBBBBBBB I know WinMerge has a "IgnoreColumns" plugin but I have never go this working. In this example I would rename it IgnoreColumns_1-7, 20-22.dll, select it in the plugins menu, and choose "Pre-Differ." but it has never worked. I am going to be comparing huge files that I don't want to modify. I'm not opposed to stream editing them in the comparison with sed or something like that, but I would prefer not to modify the actual files. I have not chose to feed sed to diff yet just because I was hoping for for a more visual view of the data.

    Read the article

  • How to prevent Outlook from receiving multiple copies of the same email

    - by martani_net
    This question might be asked already, but it's different from this one. My boss has Outlook 2003, when he synchronize his emails while connecting through the local server (using Exchange I guess) he gets his emails normally. Once he is outside (not connection to our LAN) he gets each email duplicated 3 or 4 times. Does anyone experienced this before? and how can we fix this? Please no links to FAQ pages. For info, we are using Kaspersky anti virus and Windows 2003 server, with windows XP clients. [Update] Actually we have a bunch of 5 or 6 email accounts on Outlook, and only one of them recieve duplicated copies of the same email, all the others are cool. Further more all these email are using the sae service, Gmail for example. [Update 2] I just found out that Outlook is configured to remove emails from the server already, also, some emails exceeds 5 copies! Thank you

    Read the article

  • Removing Duplicate entries in grub2 Ubuntu 9.10

    - by Anders
    I have made a custom grub2 menu however, both the default and the custom show together. So my grub looks like the list below, the bolded entries are my custom ones. How do I get rid of the duplicates? I have tried apt-get remove and deleting old kernels. I am a bit lost. Thanks! in Advance. ubuntu,linux ... ubuntu,linux recovery memtest memtest windows7 windows7 ubuntu linux ubuntu linux recover I have tried apt-get remove I have tried marking and removing older kernels. This is how I made my custom grub by the way. I copied and pasted the grub.cfg menuentry code into the custom one and just renamed the titles so it would be perfectly clear for the user who doesn't want to know what version # it is.

    Read the article

  • Point dns server to root dns servers [duplicate]

    - by Dhaksh
    This question already has an answer here: What is a glue record? 3 answers Why does DNS work the way it does? 4 answers I have setup a custom authoritative only DNS server using bind9. Its a Master ans Slave method. Assume DNS Servers are: ns1.customdnsserver.com [192.168.91.129] ==> Master ns2.customdnsserver.com [192.168.91.130] ==> Slave Now i will host few shared hosting websites in my own web server. Where i will link above Nameservers to my domains in shared hosting. My Question is: How do i tell root DNS servers about my own authoritative only DNS server? So that when someone queries for domain www.example.com and if the domain's website is hosted in my shared hosting i want root servers to point the query to my own DNS Server so that the www.example.com get resolved for IP address.

    Read the article

  • Subnet mask and how to resolve IP range [duplicate]

    - by user2789433
    This question already has an answer here: How does IPv4 Subnetting Work? 5 answers If you click on this link WHO IS query You will see the results from a who is query for a random IP address. On the line "inetnum": "122.4.0.0/14", What does it mean for the prefix to be 14? I am using this as a reference Subnet Mask Cheatsheet While resolving it, I get a very wide range which is something like 122.7.0.0-122.4.0.0 I am not able to understand how the IP range is calculate from the subnet mask and I am only able to find calculators online and not a method to solve it.

    Read the article

  • Squirrelmail receiving duplicate emails

    - by Austin
    A client of mine is experiencing issues with his email, it appears that whenever he receives email from a certain domain it comes as duplicates. Not only are they duplicates but the duplicated items have a (+) sign next to them which usually indicates an attachment. Could this be because of a forwarding issue? Here are the headers: Return-Path: <[email protected]> Received: from bigcat.centralmasswebdesign.com (root@localhost) by tarbellconstruction.com (8.13.1/8.13.1) with ESMTP id o4OFnO23003379 for <[email protected]>; Mon, 24 May 2010 11:49:24 -0400 X-ClientAddr: 72.249.26.200 Received: from mf3.spamfiltering.com (mf3.spamfiltering.com [72.249.26.200]) by bigcat.centralmasswebdesign.com (8.13.1/8.13.1) with ESMTP id o4OFnOjF005520 for <[email protected]>; Mon, 24 May 2010 11:49:24 -0400 X-Envelope-From: [email protected] X-Envelope-To: [email protected] Received: From 67-132-16-226.dia.static.qwest.net (67.132.16.226) by mf3.spamfiltering.com (MAILFOUNDRY) id 6lzIAmdLEd+oFQAw for [email protected]; Mon, 24 May 2010 15:49:23 -0000 (GMT) Received: from mail pickup service by WMA2-EXCH1.NELCO-USA.net with Microsoft SMTPSVC; Mon, 24 May 2010 11:49:18 -0400 Content-Transfer-Encoding: 7bit Importance: normal Priority: normal X-MimeOLE: Produced By Microsoft MimeOLE V6.00.3790.4325 Content-Class: urn:content-classes:message MIME-Version: 1.0 Content-Type: multipart/mixed; boundary="----_=_NextPart_001_01CAFB58.AAB268D0" Subject: weekly activity report for week ending May 22, 2010 Date: Mon, 24 May 2010 11:49:16 -0400 Message-ID: <15BCC4D99E8CBF48A2FA37A318CFF5C801209CCC@wma2-exch1.NELCO-USA.net> X-MS-Has-Attach: yes X-MS-TNEF-Correlator: Thread-Topic: weekly activity report for week ending May 22, 2010 thread-index: Acr7WKpdCelRCiocT1eBY2YN5Ma8DA== From: "Mike LeBlanc" <[email protected]> To: "Keith Berube" <[email protected]>, "Ken Tarbell" <[email protected]> X-OriginalArrivalTime: 24 May 2010 15:49:18.0361 (UTC) FILETIME=[AB546890:01CAFB58]

    Read the article

  • Eliminating Duplicate Printers on Print Server 2008 R2

    - by user123247
    I added a print server role to our new 2008 R2 server and started adding printers to it that will be available to Remote Desktop sessions. When I added the Remote Desktop services role, I specified printer redirection, thinking that would be a good thing. On the PCs where I am testing all this, I added the network printers locally so that they would have the printer available for local use. When I logon to the 2008 R2 server, I notice that the printers I added are out there twice... once on the 2008 R2 server and an additional time redirected from my PC. Is there some way to eliminate this duplication w/o eliminating redirection?

    Read the article

  • Duplicate incoming TCP traffic on Debian Squeeze

    - by Erwan Queffélec
    I have to test a homebrew server that accepts a lot of incoming TCP traffic on a single port. The protocol is homebrew as well. For testing purposes, I'd like to send this traffic both : - to the production server (say, listening on port 12345) - to the test server (say, listening on port 23456) My clients apps are "dumb" : they never read data back, and the server never replies anyway, my server only accepts connections, and do statistical computations and store/forward/service both raw and computed data. Actually, client apps and hardware are so simple there is no way I can tell clients to send their stream on both servers... And using "fake" clients is not good enough. What could be the simplest solution ? I can of course write an intermediary app that just copy incoming data and send it back to the testing server, pretending to be the client. I have a single server running Squeeze and have total control over it. Thanks in advance for your replies.

    Read the article

  • Linux (DUP!) ping packages

    - by Darkmage
    i cant seem t figure out what is going on here. The Linux machine I am using is running as a VM on a Win7 machine using Virtual Box running as a service. If i ping the win7 Host i get ok result. root@Virtual-Box:/home/glennwiz# ping -c 100000 -s 10 -i 0.02 192.168.1.100 PING 192.168.1.100 (192.168.1.100) 10(38) bytes of data. 18 bytes from 192.168.1.100: icmp_seq=1 ttl=128 time=1.78 ms 18 bytes from 192.168.1.100: icmp_seq=2 ttl=128 time=1.68 ms if i ping localhost im ok root@Virtual-Box:/home/glennwiz# ping -c 100000 -s 10 -i 0.02 localhost PING localhost (127.0.0.1) 10(38) bytes of data. 18 bytes from localhost (127.0.0.1): icmp_seq=1 ttl=64 time=0.255 ms 18 bytes from localhost (127.0.0.1): icmp_seq=2 ttl=64 time=0.221 ms but if i ping gateway i get DUP packets root@Virtual-Box:/home/glennwiz# ping -c 100000 -s 10 -i 0.02 192.168.1.1 PING 192.168.1.1 (192.168.1.1) 10(38) bytes of data. 18 bytes from 192.168.1.1: icmp_seq=1 ttl=64 time=1.27 ms 18 bytes from 192.168.1.1: icmp_seq=1 ttl=64 time=1.46 ms (DUP!) 18 bytes from 192.168.1.1: icmp_seq=2 ttl=64 time=22.1 ms 18 bytes from 192.168.1.1: icmp_seq=2 ttl=64 time=22.4 ms (DUP!) if i ping other machine on same LAN i stil get dups. pinging remote hosts also gives (DUP!) result root@Virtual-Box:/home/glennwiz# ping -c 100000 -s 10 -i 0.02 www.vg.no PING www.vg.no (195.88.55.16) 10(38) bytes of data. 18 bytes from www.vg.no (195.88.55.16): icmp_seq=1 ttl=245 time=10.0 ms 18 bytes from www.vg.no (195.88.55.16): icmp_seq=1 ttl=245 time=10.3 ms (DUP!) 18 bytes from www.vg.no (195.88.55.16): icmp_seq=2 ttl=245 time=10.3 ms 18 bytes from www.vg.no (195.88.55.16): icmp_seq=2 ttl=245 time=10.6 ms (DUP!)

    Read the article

  • Best way to Duplicate a Laptop's Hard Drive One-to-One

    - by Urda
    I have a Lenovo X61 Tablet computer, with a plain SATA drive inside. I have windows 7 and Ubuntu 9.10 dual booting on the computer. I want to back up both of these OS's, and their special partitions (Windows 7 has one, and of course the Linux Swap). I want a one-to-one backup, all of my mission critical data is already backed up, but I would like to get a snapshot, and store it on a larger file server at home for quick recovery. What is the best approach to do this?

    Read the article

  • How to Track Duplicate Downloads

    - by user1089173
    I have a product and we are running a campaign for it to allow users to download a trial version. My questions is there any way to detect multiple downloads from the same computer but behind a proxy. For example if a person uses a proxy server, changes his/her ip and downloads our trial version multiple times from different Ip's, is there a way to detect that it is the same person who's downloading the s/w. We use only Name and Email addresses to be entered before downloading our s/w and that can easily be created. We cannot add any other fields to the form (like phoneno.)

    Read the article

  • Rewrite rule Mod_Proxy truncate file name [duplicate]

    - by Valerio Cicero
    This question already has an answer here: Redirect, Change URLs or Redirect HTTP to HTTPS in Apache - Everything You Ever Wanted How to Know about Mod_Rewrite Rules but Were Afraid to Ask 5 answers I search online for the solution, but nothing :(. I write this simple rule RewriteRule ^(.*)$ http://www.mysite.com/$1 [P,NE,QSA,L] In mysite.it i have an .htaccess with this rule and it's ok, but if i have a link "http://www.mysite.it/public/file name.html" the server point to "http://www.mysite.it/public/file" I try many solution but i can't solve. I try this and many shades of... RewriteRule ^(.*)(%20)(.*)$ "http://www.mysite.com/$1$3" [P,NE,QSA,L] Thanks!

    Read the article

< Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >