  • How can a wix custom action dll call be made to use the debug runtime via a merge module?

    - by Benj
    I'm trying to create a debug build with a corresponding debug installer for our product. I'm new to Wix so please forgive any naivety contained herein. The debug Dlls in my project are dependent on both the VS2008 and the VS2008SP1 debug runtimes. I've created a merge module feature in wix to bundle those runtimes with my installer. <Include xmlns="http://schemas.microsoft.com/wix/2006/wi"> <!-- Include our 'variables' file --> <!--<?include variables.wxi ?>--> <!--<Fragment>--> <DirectoryRef Id="TARGETDIR"> <!-- Always install the 32 bit ATL/CRT libraries, but only install the 64 bit ones on a 64 bit build --> <Merge Id="AtlFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_ATL_x86.msm" DiskId="1" Language="1033"/> <Merge Id="AtlPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_ATL_x86.msm" DiskId="1" Language="1033"/> <Merge Id="CrtFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugCRT_x86.msm" DiskId="1" Language="1033"/> <Merge Id="CrtPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugCRT_x86.msm" DiskId="1" Language="1033"/> <Merge Id="MfcFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugMFC_x86.msm" DiskId="1" Language="1033"/> <Merge Id="MfcPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugMFC_x86.msm" DiskId="1" Language="1033"/> <!-- If this is a 64 bit build, install the relevant modules --> <?if $(env.Platform) = "x64" ?> <Merge Id="AtlFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_ATL_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="AtlPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_ATL_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="CrtFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugCRT_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="CrtPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugCRT_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="MfcFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugMFC_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="MfcPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugMFC_x86_x64.msm" DiskId="1" Language="1033"/> <?endif?> </DirectoryRef> <Feature Id="MS2008_SP1_DbgRuntime" Title="VC2008 Debug Runtimes" AllowAdvertise="no" Display="hidden" Level="1"> <!-- 32 bit libraries --> <MergeRef Id="AtlFiles_x86"/> <MergeRef Id="AtlPolicy_x86"/> <MergeRef Id="CrtFiles_x86"/> <MergeRef Id="CrtPolicy_x86"/> <MergeRef Id="MfcFiles_x86"/> <MergeRef Id="MfcPolicy_x86"/> <!-- 64 bit libraries --> <?if $(env.Platform) = "x64" ?> <MergeRef Id="AtlFiles_x64"/> <MergeRef Id="AtlPolicy_x64"/> <MergeRef Id="CrtFiles_x64"/> <MergeRef Id="CrtPolicy_x64"/> <MergeRef Id="MfcFiles_x64"/> <MergeRef Id="MfcPolicy_x64"/> <?endif?> </Feature> <!--</Fragment>--> </Include> If I'm doing a debug build of the installer, I include that feature like so: <!-- The 'Feature' that contains the debug CRT/ATL libraries --> <?if $(var.Configuration) = "Debug"?> <?include ..\includes\MS2008_SP1_DbgRuntime.wxi?> <?endif?> The only problem is that my installer also includes a custom action which is also dependent on the debug runtime: <!-- Private key installer --> <Binary Id="InstallPrivateKey" SourceFile="..\InstallPrivateKey\win32\$(var.Configuration)\InstallPrivateKey.dll"></Binary> <CustomAction Id='InstallKey' BinaryKey='InstallPrivateKey' DllEntry='InstallPrivateKey'/> So how can I package the debug run time in such a way that the custom action also has access to it?

    Read the article

  • Sending email to gmail account using c++ on windows error check

    - by LCD Fire
    I know this has been disscused a lot, but I I'm not asking how to do it, I'm just asking why it doesn't work. What I am doing wrong. It says that the email was sent succesfully but I don't see it in my inbox. I want to send an email to a gmail account, not through it. #include <iostream> #include <windows.h> #include <fstream> #include <conio.h> #pragma comment(lib, "ws2_32.lib") // Insist on at least Winsock v1.1 const int VERSION_MAJOR = 1; const int VERSION_MINOR = 1; #define CRLF "\r\n" // carriage-return/line feed pair using namespace std; // Basic error checking for send() and recv() functions void Check(int iStatus, char *szFunction) { if((iStatus != SOCKET_ERROR) && (iStatus)) return; cerr<< "Error during call to " << szFunction << ": " << iStatus << " - " << GetLastError() << endl; } int main(int argc, char *argv[]) { int iProtocolPort = 25; char szSmtpServerName[64] = ""; char szToAddr[64] = ""; char szFromAddr[64] = ""; char szBuffer[4096] = ""; char szLine[255] = ""; char szMsgLine[255] = ""; SOCKET hServer; WSADATA WSData; LPHOSTENT lpHostEntry; LPSERVENT lpServEntry; SOCKADDR_IN SockAddr; // Check for four command-line args //if(argc != 5) // ShowUsage(); // Load command-line args lstrcpy(szSmtpServerName, "smtp.gmail.com"); lstrcpy(szToAddr, "[email protected]"); lstrcpy(szFromAddr, "[email protected]"); // Create input stream for reading email message file ifstream MsgFile("D:\\d.txt"); // Attempt to intialize WinSock (1.1 or later) if(WSAStartup(MAKEWORD(VERSION_MAJOR, VERSION_MINOR), &WSData)) { cout << "Cannot find Winsock v" << VERSION_MAJOR << "." << VERSION_MINOR << " or later!" << endl; return 1; } // Lookup email server's IP address. lpHostEntry = gethostbyname(szSmtpServerName); if(!lpHostEntry) { cout << "Cannot find SMTP mail server " << szSmtpServerName << endl; return 1; } // Create a TCP/IP socket, no specific protocol hServer = socket(PF_INET, SOCK_STREAM, 0); if(hServer == INVALID_SOCKET) { cout << "Cannot open mail server socket" << endl; return 1; } // Get the mail service port lpServEntry = getservbyname("mail", 0); // Use the SMTP default port if no other port is specified if(!lpServEntry) iProtocolPort = htons(IPPORT_SMTP); else iProtocolPort = lpServEntry->s_port; // Setup a Socket Address structure SockAddr.sin_family = AF_INET; SockAddr.sin_port = iProtocolPort; SockAddr.sin_addr = *((LPIN_ADDR)*lpHostEntry->h_addr_list); // Connect the Socket if(connect(hServer, (PSOCKADDR) &SockAddr, sizeof(SockAddr))) { cout << "Error connecting to Server socket" << endl; return 1; } // Receive initial response from SMTP server Check(recv(hServer, szBuffer, sizeof(szBuffer), 0), "recv() Reply"); // Send HELO server.com sprintf(szMsgLine, "HELO %s%s", szSmtpServerName, CRLF); Check(send(hServer, szMsgLine, strlen(szMsgLine), 0), "send() HELO"); Check(recv(hServer, szBuffer, sizeof(szBuffer), 0), "recv() HELO"); // Send MAIL FROM: <[email protected]> sprintf(szMsgLine, "MAIL FROM:<%s>%s", szFromAddr, CRLF); Check(send(hServer, szMsgLine, strlen(szMsgLine), 0), "send() MAIL FROM"); Check(recv(hServer, szBuffer, sizeof(szBuffer), 0), "recv() MAIL FROM"); // Send RCPT TO: <[email protected]> sprintf(szMsgLine, "RCPT TO:<%s>%s", szToAddr, CRLF); Check(send(hServer, szMsgLine, strlen(szMsgLine), 0), "send() RCPT TO"); Check(recv(hServer, szBuffer, sizeof(szBuffer), 0), "recv() RCPT TO"); // Send DATA sprintf(szMsgLine, "DATA%s", CRLF); Check(send(hServer, szMsgLine, strlen(szMsgLine), 0), "send() DATA"); Check(recv(hServer, szBuffer, sizeof(szBuffer), 0), "recv() DATA"); //strat writing about the subject, end it with two CRLF chars and after that you can //write data to the body oif the message sprintf(szMsgLine, "Subject: My own subject %s%s", CRLF, CRLF); Check(send(hServer, szMsgLine, strlen(szMsgLine), 0), "send() DATA"); // Send all lines of message body (using supplied text file) MsgFile.getline(szLine, sizeof(szLine)); // Get first line do // for each line of message text... { sprintf(szMsgLine, "%s%s", szLine, CRLF); Check(send(hServer, szMsgLine, strlen(szMsgLine), 0), "send() message-line"); MsgFile.getline(szLine, sizeof(szLine)); // get next line. } while(!MsgFile.eof()); // Send blank line and a period sprintf(szMsgLine, "%s.%s", CRLF, CRLF); Check(send(hServer, szMsgLine, strlen(szMsgLine), 0), "send() end-message"); Check(recv(hServer, szBuffer, sizeof(szBuffer), 0), "recv() end-message"); // Send QUIT sprintf(szMsgLine, "QUIT%s", CRLF); Check(send(hServer, szMsgLine, strlen(szMsgLine), 0), "send() QUIT"); Check(recv(hServer, szBuffer, sizeof(szBuffer), 0), "recv() QUIT"); // Report message has been sent cout<< "Sent " << argv[4] << " as email message to " << szToAddr << endl; // Close server socket and prepare to exit. closesocket(hServer); WSACleanup(); _getch(); return 0; }

    Read the article

  • how to use a class method as a WIN32 application callback method (WINPROC)... Error static struct HI

    - by numerical25
    I am receiving errors and at the same time trying to make this work so please read what I got to say. Thanks.... I am creating a c++ application and majority of the application is encapsulated into a class. That means that my WinProc function is a static class method that I use as my call back method for my win32 application. The problem is that since I created that as a win32 application, every class member I use inside that method has to be static as well. Including my HINSTANCE class which I use inside of it. Now I receive this error error LNK2001: unresolved external symbol "public: static struct HINSTANCE__ I need to figure out how to make this all work and below is my class declaration. My static member static HINSTANCE m_hInst is causing the error I believe. #pragma once #include "stdafx.h" #include "resource.h" #define MAX_LOADSTRING 100 class RenderEngine { protected: int m_width; int m_height; ATOM RegisterEngineClass(); public: static HINSTANCE m_hInst; //<------ This is causing the error HWND m_hWnd; int m_nCmdShow; TCHAR m_szTitle[MAX_LOADSTRING]; // The title bar text TCHAR m_szWindowClass[MAX_LOADSTRING]; // the main window class name bool InitWindow(); bool InitDirectX(); bool InitInstance(); //static functions static LRESULT CALLBACK WndProc(HWND hWnd, UINT message, WPARAM wParam, LPARAM lParam); static INT_PTR CALLBACK About(HWND hDlg, UINT message, WPARAM wParam, LPARAM lParam); int Run(); }; Below is the implementation #include "stdafx.h" #include "RenderEngine.h" bool RenderEngine::InitWindow() { RenderEngine::m_hInst = NULL; // Initialize global strings LoadString(m_hInst, IDS_APP_TITLE, m_szTitle, MAX_LOADSTRING); LoadString(m_hInst, IDC_RENDERENGINE, m_szWindowClass, MAX_LOADSTRING); if(!RegisterEngineClass()) { return false; } if(!InitInstance()) { return false; } return true; } ATOM RenderEngine::RegisterEngineClass() { WNDCLASSEX wcex; wcex.cbSize = sizeof(WNDCLASSEX); wcex.style = CS_HREDRAW | CS_VREDRAW; wcex.lpfnWndProc = RenderEngine::WndProc; wcex.cbClsExtra = 0; wcex.cbWndExtra = 0; wcex.hInstance = m_hInst; wcex.hIcon = LoadIcon(m_hInst, MAKEINTRESOURCE(IDI_RENDERENGINE)); wcex.hCursor = LoadCursor(NULL, IDC_ARROW); wcex.hbrBackground = (HBRUSH)(COLOR_WINDOW+1); wcex.lpszMenuName = MAKEINTRESOURCE(IDC_RENDERENGINE); wcex.lpszClassName = m_szWindowClass; wcex.hIconSm = LoadIcon(wcex.hInstance, MAKEINTRESOURCE(IDI_SMALL)); return RegisterClassEx(&wcex); } LRESULT CALLBACK RenderEngine::WndProc(HWND hWnd, UINT message, WPARAM wParam, LPARAM lParam) { int wmId, wmEvent; PAINTSTRUCT ps; HDC hdc; switch (message) { case WM_COMMAND: wmId = LOWORD(wParam); wmEvent = HIWORD(wParam); // Parse the menu selections: switch (wmId) { case IDM_ABOUT: DialogBox(m_hInst, MAKEINTRESOURCE(IDD_ABOUTBOX), hWnd, About); break; case IDM_EXIT: DestroyWindow(hWnd); break; default: return DefWindowProc(hWnd, message, wParam, lParam); } break; case WM_PAINT: hdc = BeginPaint(hWnd, &ps); // TODO: Add any drawing code here... EndPaint(hWnd, &ps); break; case WM_DESTROY: PostQuitMessage(0); break; default: return DefWindowProc(hWnd, message, wParam, lParam); } return 0; } bool RenderEngine::InitInstance() { m_hWnd = NULL; m_hWnd = CreateWindow(m_szWindowClass, m_szTitle, WS_OVERLAPPEDWINDOW, CW_USEDEFAULT, 0, CW_USEDEFAULT, 0, NULL, NULL, m_hInst, NULL); if (!m_hWnd) { return FALSE; } if(!ShowWindow(m_hWnd, m_nCmdShow)) { return false; } UpdateWindow(m_hWnd); return true; } // Message handler for about box. INT_PTR CALLBACK RenderEngine::About(HWND hDlg, UINT message, WPARAM wParam, LPARAM lParam) { UNREFERENCED_PARAMETER(lParam); switch (message) { case WM_INITDIALOG: return (INT_PTR)TRUE; case WM_COMMAND: if (LOWORD(wParam) == IDOK || LOWORD(wParam) == IDCANCEL) { EndDialog(hDlg, LOWORD(wParam)); return (INT_PTR)TRUE; } break; } return (INT_PTR)FALSE; } int RenderEngine::Run() { MSG msg; HACCEL hAccelTable; hAccelTable = LoadAccelerators(m_hInst, MAKEINTRESOURCE(IDC_RENDERENGINE)); // Main message loop: while (GetMessage(&msg, NULL, 0, 0)) { if (!TranslateAccelerator(msg.hwnd, hAccelTable, &msg)) { TranslateMessage(&msg); DispatchMessage(&msg); } } return (int) msg.wParam; } and below is the code being used within the WinMain RenderEngine go; int APIENTRY _tWinMain(HINSTANCE hInstance, HINSTANCE hPrevInstance, LPTSTR lpCmdLine, int nCmdShow) { UNREFERENCED_PARAMETER(hPrevInstance); UNREFERENCED_PARAMETER(lpCmdLine); // TODO: Place code here. RenderEngine::m_hInst = hInstance; go.m_nCmdShow = nCmdShow; if(!go.InitWindow()) { return 0; } go.Run(); return 0; } If anything does not make any sense, then I apologize, I am a newb. Thanks for the help!!

    Read the article

  • How is "Make Object ID" implemented in the .NET debugger?

    - by Omer Raviv
    Hi, I would like know how this feature is implemented in VS - I understand it holds some sort of weak-reference to the object in the debugged-application's memory, but how exactly is it accomplished? I know simply tracking the address (as in native code) wouldn't work, because the GC might move the object about, invalidating the address. Thanks.

    Read the article

  • VS 2010 Doesn't recognize Middleware DLLs

    - by Amit
    Hi I have VS 2010 Ultimate installed on Win 7 Enterprise (32 bit). In my middleware I have some DLLS referred. If i try to build the solution, some of the DLLs are not getting recogninized and the solution will not build. The same solution builds fine on VS 2008. Any Idea why this happens?

    Read the article

  • How to Compute a Database Column in .NET

    - by Michael
    I have a Database named CarsType.accdb there are four fields in the data base Item_Name, Item_Num, Item_Qty, Item_Cost. I am able to get the database to display my data in VisualBasic but I am not sure how to get the total cost to appear in my label (lblTotalCost). I prefer doing it in VB versus writing in my access program. All I am wanting to do it multiply item_qty * Item_Cost How would I go about doing that?

    Read the article

  • WCF Service error received when using TCP: "The message could not be dispatched..."

    - by StM
    I am new to creating WCF services. I have created a WCF web service in VS2008 that is running on IIS 7. When I use http the service works perfectly. When I configure the service for TCP and run I get the following error message. There was a communication problem. The message could not be dispatched because the service at the endpoint address 'net:tcp://elec:9090/CoordinateIdTool_Tcp/IdToolService.svc is unavailable for the protocol of the address. I have searched a lot of forums, including this one, for a resolution but nothing has worked. Everything appears to be set up correctly on IIS 7. WAS has been set up to run. The default web site has a net.tcp binding and the application has net.tcp under the enabled protocols. I am including what I think is the important part of the web.config from the host project and also the app.config from the client project I am using to test the service. Hopefully someone can spot my error. Thanks in advance for any help or recommendations that anyone can provide. Web.Config <bindings> <wsHttpBinding> <binding name="wsHttpBindingNoMsgs"> <security mode="None" /> </binding> </wsHttpBinding> </bindings> <services> <service behaviorConfiguration="CogIDServiceHost.ServiceBehavior" name="CogIDServiceLibrary.CogIdService"> <endpoint address="" binding="wsHttpBinding" bindingConfiguration="wsHttpBindingNoMsgs" contract="CogIDServiceLibrary.CogIdTool"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="mex" binding="mexHttpBinding" bindingConfiguration="" contract="IMetadataExchange" /> <endpoint name="CoordinateIdService_TCP" address="net.tcp://elec:9090/CoordinateIdTool_Tcp/IdToolService.svc" binding="netTcpBinding" bindingConfiguration="" contract="CogIDServiceLibrary.CogIdTool"> <identity> <dns value="localhost" /> </identity> </endpoint> </service> </services> <behaviors> <serviceBehaviors> <behavior name="CogIDServiceHost.ServiceBehavior"> <serviceMetadata httpGetEnabled="true" /> <serviceDebug includeExceptionDetailInFaults="false" /> </behavior> </serviceBehaviors> </behaviors> App.Config <system.serviceModel> <diagnostics performanceCounters="Off"> <messageLogging logEntireMessage="true" logMalformedMessages="false" logMessagesAtServiceLevel="false" logMessagesAtTransportLevel="false" /> </diagnostics> <behaviors /> <bindings> <wsHttpBinding> <binding name="WSHttpBinding_CogIdTool" closeTimeout="00:01:00" openTimeout="00:01:00" receiveTimeout="00:10:00" sendTimeout="00:01:00" bypassProxyOnLocal="false" transactionFlow="false" hostNameComparisonMode="StrongWildcard" maxBufferPoolSize="524288" maxReceivedMessageSize="65536" messageEncoding="Text" textEncoding="utf-8" useDefaultWebProxy="true" allowCookies="false"> <readerQuotas maxDepth="32" maxStringContentLength="8192" maxArrayLength="16384" maxBytesPerRead="4096" maxNameTableCharCount="16384" /> <reliableSession ordered="true" inactivityTimeout="00:10:00" enabled="false" /> <security mode="None"> <transport clientCredentialType="Windows" proxyCredentialType="None" realm="" /> <message clientCredentialType="Windows" negotiateServiceCredential="true" establishSecurityContext="true" /> </security> </binding> <binding name="wsHttpBindingNoMsg"> <security mode="None"> <transport clientCredentialType="Windows" /> <message clientCredentialType="Windows" /> </security> </binding> </wsHttpBinding> </bindings> <client> <endpoint address="http://sdet/CogId_WCF/IdToolService.svc" binding="wsHttpBinding" bindingConfiguration="wsHttpBindingNoMsg" contract="CogIdServiceReference.CogIdTool" name="IISHostWsHttpBinding"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="http://localhost:1890/IdToolService.svc" binding="wsHttpBinding" bindingConfiguration="WSHttpBinding_CogIdTool" contract="CogIdServiceReference.CogIdTool" name="WSHttpBinding_CogIdTool"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="http://elec/CoordinateIdTool/IdToolService.svc" binding="wsHttpBinding" bindingConfiguration="wsHttpBindingNoMsg" contract="CogIdServiceReference.CogIdTool" name="IIS7HostWsHttpBinding_Elec"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="net.tcp://elec:9090/CoordinateIdTool_Tcp/IdToolService.svc" binding="netTcpBinding" bindingConfiguration="" contract="CogIdServiceReference.CogIdTool" name="IIS7HostTcpBinding_Elec" > <identity> <dns value="localhost"/> </identity> </endpoint> </client> </system.serviceModel>

    Read the article

  • clicking browser back button is opening a link in the previous page.

    - by Jebli
    I am using the below code protected void lnk_Click(object sender, EventArgs e) { try { string strlink = ConfigurationManager.AppSettings["link"].ToString().Trim(); StringBuilder sb = new StringBuilder(); sb.Append("<script type = 'text/javascript'>"); sb.Append("window.open('"); sb.Append(strlink); sb.Append("');"); sb.Append("</script>"); ClientScript.RegisterStartupScript(this.GetType(), "script", sb.ToString()); } } In the page there are two links. When i click the first link it opens a window in a new page. I do this by using the above code. I am clicking the second link in the page and navigating to another page. Now i am clicking the browser back button. Supprisingly its opening the first link. How clicking back button is opening the link in the page. I am using c# .net 2005. Please help. Thanks. Regards,enter code here Radha A

    Read the article

  • Getting a Specified Cast is not valid while importing data from Excel using Linq to SQL

    - by niceoneishere
    This is my second post. After learning from my first post how fantastic is to use Linq to SQL, I wanted to try to import data from a Excel sheet into my SQL database. First My Excel Sheet: it contains 4 columns namely ItemNo ItemSize ItemPrice UnitsSold I have a created a database table with the following fields table name ProductsSold Id int not null identity --with auto increment set to true ItemNo VarChar(10) not null ItemSize VarChar(4) not null ItemPrice Decimal(18,2) not null UnitsSold int not null Now I created a dal.dbml file based on my database and I am trying to import the data from excel sheet to db table using the code below. Everything is happening on click of a button. private const string forecast_query = "SELECT ItemNo, ItemSize, ItemPrice, UnitsSold FROM [Sheet1$]"; protected void btnUpload_Click(object sender, EventArgs e) { var importer = new LinqSqlModelImporter(); if (fileUpload.HasFile) { var uploadFile = new UploadFile(fileUpload.FileName); try { fileUpload.SaveAs(uploadFile.SavePath); if(File.Exists(uploadFile.SavePath)) { importer.SourceConnectionString = uploadFile.GetOleDbConnectionString(); importer.Import(forecast_query); gvDisplay.DataBind(); pnDisplay.Visible = true; } } catch (Exception ex) { Response.Write(ex.Source.ToString()); lblInfo.Text = ex.Message; } finally { uploadFile.DeleteFileNoException(); } } } // Now here is the code for LinqSqlModelImporter public class LinqSqlModelImporter : SqlImporter { public override void Import(string query) { // importing data using oledb command and inserting into db using LINQ to SQL using (var context = new WSDALDataContext()) { using (var myConnection = new OleDbConnection(base.SourceConnectionString)) using (var myCommand = new OleDbCommand(query, myConnection)) { myConnection.Open(); var myReader = myCommand.ExecuteReader(); while (myReader.Read()) { context.ProductsSolds.InsertOnSubmit(new ProductsSold() { ItemNo = myReader.GetString(0), ItemSize = myReader.GetString(1), ItemPrice = myReader.GetDecimal(2), UnitsSold = myReader.GetInt32(3) }); } } context.SubmitChanges(); } } } can someone please tell me where am I making the error or if I am missing something, but this is driving me nuts. When I debugged I am getting this error when casting from a number the value must be a number less than infinity I really appreciate it

    Read the article

  • prolog to solve grammar involving braces

    - by Abhilash Muthuraj
    I'm trying to solve DCG grammar in prolog and succeeded upto a point, i'm stuck in evaluating the expressions involving braces like these. expr( T, [’(’, 5, +, 4, ’)’, *, 7], []), expr(Z) --> num(Z). expr(Z) --> num(X), [+], expr(Y), {Z is X+Y}. expr(Z) --> num(X), [-], expr(Y), {Z is X-Y}. expr(Z) --> num(X), [*], expr(Y), {Z is X*Y}. num(D) --> [D], {number(D)}. eval(L, V, []) :- expr(V, L, []).

    Read the article

  • C# menustrip designer

    - by Iceyoshi
    Hi, I'm not sure when this happened but when I was trying to edit a menustrip in my program (in the VS designer), I noticed that the menu items had be grouped or merged. Like: File Edit Format Insert ... Instead of being able to click each menu item and add sub-items to them in the designer, they all were grouped together so I couldn't edit the menu items separately, it's quite painful. I couldn't find any properties related to this, so how could I ungroup the menu items in the designer?

    Read the article

  • Not able add .mdf file in App_data

    - by vinod R
    HI I am not able to add .mdf file in App_data(vs 2008 web developer). If i right click on App_data and try to add new item and select sql server file and click OK. I am getting error as "Connections to Sql Server files(*.mdf) require SQL Server Express 2005 to function properly.Please verify the installation of the component or download from the url:http://www.microsoft.com/Sqlserver/2005/" But i have installed SQL Server Express 2005 still it is giving the same error(i have installed sql server after installing vs 2008) Please help me

    Read the article

  • problem in working with thread

    - by Xaver
    Ihave the tree view in which i have file system of logical disk. When user select some files and folders and press button programm evaluate the size of selected files and folders. this function may takes a long time. i decide do thread which will run this function. This function works with array of TreeNode. but then i want to now was it node expaned or not compiler say: "attempt to access control "treeview1" not from the thread, in which it was created." Why it appeared? Next code is show how i create array of Nodes which i send to new thread: void frmMain::FillSelected(TreeNode^ a, array<TreeNode^>^ *Paths) { if (a->Parent == nullptr) { for(int j = 0;j < a->Nodes->Count;j++) { if ((a->Nodes[j]->ImageIndex == 1)&&(a->Nodes[j]->Checked==true)) { (*Paths)->Resize((*Paths), (*Paths)->Length + 1); (*Paths)[(*Paths)->Length-1] = a->Nodes[j]; } } } for(int i = 0;i < a->Nodes->Count;i++) { if (a->Parent == nullptr) { FillSelected(a->Nodes[i], Paths); } else { if(a->Nodes[i]->Checked == true) { (*Paths)->Resize((*Paths), (*Paths)->Length + 1); (*Paths)[(*Paths)->Length-1] = a->Nodes[i]; } if ((a->Nodes[i]->Nodes->Count > 0)&&(a->Nodes[i]->Nodes[0]->FullPath != (a->Nodes[i]->FullPath + "\\"))) { FillSelected(a->Nodes[i], Paths); } } } return; }

    Read the article

  • Convert char array to UNICODE in MFC C++

    - by chathuradd
    I'm using the folowing code to read files from a folder in windows. However since this a MFC application I have to convert the char array to UNICODE. For example if I hard code the path as "C:\images3\test\" as shown below the code works. WIN32_FIND_DATA FindFileData; HANDLE hFind = INVALID_HANDLE_VALUE; hFind = FindFirstFile(_T("C:\images3\test\"), &FindFileData); What I want is to get this working as follows: char* pathOfFileType; hFind = FindFirstFile(_T(pathOfFileType), &FindFileData); Can anyone tell me how to fix this problem ? Thanks

    Read the article

  • Including javascript files from other projects inside the same solution

    - by gnomixa
    I have a project called WebResources where I have all the JS files that I intend to use in 2 other projects (all three projects sit in the same solution). I just spent 2 hours playing around with the file paths and VS just doesn't see the JS file (unless I specify the full path with the drive letter). Is there a trick to including javascript files relatively from other projects? My file structure is something like: Project1 Default.aspx Project2 WebResourcesProject /js testToInclude.js No matter how I try to include testToInclude.js inside Default.aspx, VS doesn't see it. Any ideas?

    Read the article

  • .config file not loaded from working directory

    - by Phil Coveney
    I am new to using .config files, having worked on apps that use .INI files and the registry until very recently. I am seeing a behavior in VS2008 that I would not anticipate, and wonder if it is the expected one. When I configure the Working Directory setting in the VS2008 IDE for my Foo.exe application, I would have guessed that Foo.exe.config would get loaded from that Working Directory. It does not; it gets loaded from the ..\bin\Debug directory, even if I have a Foo.exe.config file in that Working Directory. If I examine the Environment.CurrentDirectory while the configuration is being applied by setting a breakpoint, I see that it is ..\bin\Debug. When I examine the Environment.CurrentDirectory after my main UI's Loaded event, it is set to the Working Directory I applied in the IDE. Is this correct? (Why?)

    Read the article

  • Can we Move the vsmdi file

    - by Raghuram Raichooti
    When a test project is craeted two other files are also created. Suppose My Project Name is TestProject1: Folder: TestProject1, LocalTestRun.testrunconfig, TestProject1.sln, TestProject1.suo, TestProject1.vsmdi And one more folder named: TestResults My requirement is i have many project and folders in solution and wanted to move the .vsmdi file and .tesrunconfig file and testrun folder to my specified location. Can i do this, if yes how can i do it.

    Read the article

  • Implementing sub fields in a PropertyGrid

    - by evolve
    Alright so my terminology when it comes to C# isn't great, so I'll attempt to explain this with a small example. If you create a class which you are using within a PropertyGrid and you have the following values: class Test { public Point example { get; set; } } This will produce a PropertyGrid which has an expandable object "example" which has fields X and Y in order to create a "Point". I'm attempting to create an object "name" which has fields "firstname" and "lastname", so I have: class Test { public Name example { get; set; } } public struct Name { public string firstname { get; set; } public string lastname { get; set; } } This however isn't working as intended. I think I need to override some method(s) in order to get this working, however since I don't really have the terminology down for PropertyGrids it is difficult for me to find a solution. Any help would be great.

    Read the article

  • Do I have to remove VS 2010 beta1 in order to get a web app to work on asp.net 2.0?

    - by Galilyou
    I think the title is enough :). I have VS 2010 beta1 installed, and I wish to run an asp.net mvc application on my local IIS. The problem is, the asp.net 4.0 runtime is selected by default for all the web sites, when I try to change it to asp.net 2.0, I get the following error message: I click yes, then ok, and when I get back to the ASP.NET tab of my site's properties, I see the 4.0 version is selected back again! Do I have to remove VS 2010 in order to get this to work? (hopefully not) Ps: I'm using windows XP and IIS 5.1

    Read the article

  • Outlook Folder Browse Dialog???

    - by Ike
    Hello there, I'm hoping someone could help me with a quick point in the right direction. ALL I NEED is the Outlook folder browser dialog call. I am developing some plugins for Outlook using C# and this is a crucial part for both plugins. Hopefully, it is like a standard DialogResult that passes back folder information (selected folder) so that I can use this info for further processing. Can anyone help me? Thanks in advance.