Search Results

Search found 7065 results on 283 pages for 'cpu sockets'.

Page 270/283 | < Previous Page | 266 267 268 269 270 271 272 273 274 275 276 277  | Next Page >

  • Detecting HTML5/CSS3 Features using Modernizr

    - by dwahlin
    HTML5, CSS3, and related technologies such as canvas and web sockets bring a lot of useful new features to the table that can take Web applications to the next level. These new technologies allow applications to be built using only HTML, CSS, and JavaScript allowing them to be viewed on a variety of form factors including tablets and phones. Although HTML5 features offer a lot of promise, it’s not realistic to develop applications using the latest technologies without worrying about supporting older browsers in the process. If history has taught us anything it’s that old browsers stick around for years and years which means developers have to deal with backward compatibility issues. This is especially true when deploying applications to the Internet that target the general public. This begs the question, “How do you move forward with HTML5 and CSS3 technologies while gracefully handling unsupported features in older browsers?” Although you can write code by hand to detect different HTML5 and CSS3 features, it’s not always straightforward. For example, to check for canvas support you need to write code similar to the following:   <script> window.onload = function () { if (canvasSupported()) { alert('canvas supported'); } }; function canvasSupported() { var canvas = document.createElement('canvas'); return (canvas.getContext && canvas.getContext('2d')); } </script> If you want to check for local storage support the following check can be made. It’s more involved than it should be due to a bug in older versions of Firefox. <script> window.onload = function () { if (localStorageSupported()) { alert('local storage supported'); } }; function localStorageSupported() { try { return ('localStorage' in window && window['localStorage'] != null); } catch(e) {} return false; } </script> Looking through the previous examples you can see that there’s more than meets the eye when it comes to checking browsers for HTML5 and CSS3 features. It takes a lot of work to test every possible scenario and every version of a given browser. Fortunately, you don’t have to resort to writing custom code to test what HTML5/CSS3 features a given browser supports. By using a script library called Modernizr you can add checks for different HTML5/CSS3 features into your pages with a minimal amount of code on your part. Let’s take a look at some of the key features Modernizr offers.   Getting Started with Modernizr The first time I heard the name “Modernizr” I thought it “modernized” older browsers by added missing functionality. In reality, Modernizr doesn’t actually handle adding missing features or “modernizing” older browsers. The Modernizr website states, “The name Modernizr actually stems from the goal of modernizing our development practices (and ourselves)”. Because it relies on feature detection rather than browser sniffing (a common technique used in the past – that never worked that great), Modernizr definitely provides a more modern way to test features that a browser supports and can even handle loading additional scripts called shims or polyfills that fill in holes that older browsers may have. It’s a great tool to have in your arsenal if you’re a web developer. Modernizr is available at http://modernizr.com. Two different types of scripts are available including a development script and custom production script. To generate a production script, the site provides a custom script generation tool rather than providing a single script that has everything under the sun for HTML5/CSS3 feature detection. Using the script generation tool you can pick the specific test functionality that you need and ignore everything that you don’t need. That way the script is kept as small as possible. An example of the custom script download screen is shown next. Notice that specific CSS3, HTML5, and related feature tests can be selected. Once you’ve downloaded your custom script you can add it into your web page using the standard <script> element and you’re ready to start using Modernizr. <script src="Scripts/Modernizr.js" type="text/javascript"></script>   Modernizr and the HTML Element Once you’ve add a script reference to Modernizr in a page it’ll go to work for you immediately. In fact, by adding the script several different CSS classes will be added to the page’s <html> element at runtime. These classes define what features the browser supports and what features it doesn’t support. Features that aren’t supported get a class name of “no-FeatureName”, for example “no-flexbox”. Features that are supported get a CSS class name based on the feature such as “canvas” or “websockets”. An example of classes added when running a page in Chrome is shown next:   <html class=" js flexbox canvas canvastext webgl no-touch geolocation postmessage websqldatabase indexeddb hashchange history draganddrop websockets rgba hsla multiplebgs backgroundsize borderimage borderradius boxshadow textshadow opacity cssanimations csscolumns cssgradients cssreflections csstransforms csstransforms3d csstransitions fontface generatedcontent video audio localstorage sessionstorage webworkers applicationcache svg inlinesvg smil svgclippaths"> Here’s an example of what the <html> element looks like at runtime with Internet Explorer 9:   <html class=" js no-flexbox canvas canvastext no-webgl no-touch geolocation postmessage no-websqldatabase no-indexeddb hashchange no-history draganddrop no-websockets rgba hsla multiplebgs backgroundsize no-borderimage borderradius boxshadow no-textshadow opacity no-cssanimations no-csscolumns no-cssgradients no-cssreflections csstransforms no-csstransforms3d no-csstransitions fontface generatedcontent video audio localstorage sessionstorage no-webworkers no-applicationcache svg inlinesvg smil svgclippaths">   When using Modernizr it’s a common practice to define an <html> element in your page with a no-js class added as shown next:   <html class="no-js">   You’ll see starter projects such as HTML5 Boilerplate (http://html5boilerplate.com) or Initializr (http://initializr.com) follow this approach (see my previous post for more information on HTML5 Boilerplate). By adding the no-js class it’s easy to tell if a browser has JavaScript enabled or not. If JavaScript is disabled then no-js will stay on the <html> element. If JavaScript is enabled, no-js will be removed by Modernizr and a js class will be added along with other classes that define supported/unsupported features. Working with HTML5 and CSS3 Features You can use the CSS classes added to the <html> element directly in your CSS files to determine what style properties to use based upon the features supported by a given browser. For example, the following CSS can be used to render a box shadow for browsers that support that feature and a simple border for browsers that don’t support the feature: .boxshadow #MyContainer { border: none; -webkit-box-shadow: #666 1px 1px 1px; -moz-box-shadow: #666 1px 1px 1px; } .no-boxshadow #MyContainer { border: 2px solid black; }   If a browser supports box-shadows the boxshadow CSS class will be added to the <html> element by Modernizr. It can then be associated with a given element. This example associates the boxshadow class with a div with an id of MyContainer. If the browser doesn’t support box shadows then the no-boxshadow class will be added to the <html> element and it can be used to render a standard border around the div. This provides a great way to leverage new CSS3 features in supported browsers while providing a graceful fallback for older browsers. In addition to using the CSS classes that Modernizr provides on the <html> element, you also use a global Modernizr object that’s created. This object exposes different properties that can be used to detect the availability of specific HTML5 or CSS3 features. For example, the following code can be used to detect canvas and local storage support. You can see that the code is much simpler than the code shown at the beginning of this post. It also has the added benefit of being tested by a large community of web developers around the world running a variety of browsers.   $(document).ready(function () { if (Modernizr.canvas) { //Add canvas code } if (Modernizr.localstorage) { //Add local storage code } }); The global Modernizr object can also be used to test for the presence of CSS3 features. The following code shows how to test support for border-radius and CSS transforms:   $(document).ready(function () { if (Modernizr.borderradius) { $('#MyDiv').addClass('borderRadiusStyle'); } if (Modernizr.csstransforms) { $('#MyDiv').addClass('transformsStyle'); } });   Several other CSS3 feature tests can be performed such as support for opacity, rgba, text-shadow, CSS animations, CSS transitions, multiple backgrounds, and more. A complete list of supported HTML5 and CSS3 tests that Modernizr supports can be found at http://www.modernizr.com/docs.   Loading Scripts using Modernizr In cases where a browser doesn’t support a specific feature you can either provide a graceful fallback or load a shim/polyfill script to fill in missing functionality where appropriate (more information about shims/polyfills can be found at https://github.com/Modernizr/Modernizr/wiki/HTML5-Cross-Browser-Polyfills). Modernizr has a built-in script loader that can be used to test for a feature and then load a script if the feature isn’t available. The script loader is built-into Modernizr and is also available as a standalone yepnope script (http://yepnopejs.com). It’s extremely easy to get started using the script loader and it can really simplify the process of loading scripts based on the availability of a particular browser feature. To load scripts dynamically you can use Modernizr’s load() function which accepts properties defining the feature to test (test property), the script to load if the test succeeds (yep property), the script to load if the test fails (nope property), and a script to load regardless of if the test succeeds or fails (both property). An example of using load() with these properties is show next: Modernizr.load({ test: Modernizr.canvas, yep: 'html5CanvasAvailable.js’, nope: 'excanvas.js’, both: 'myCustomScript.js' }); In this example Modernizr is used to not only load scripts but also to test for the presence of the canvas feature. If the target browser supports the HTML5 canvas then the html5CanvasAvailable.js script will be loaded along with the myCustomScript.js script (use of the yep property in this example is a bit contrived – it was added simply to demonstrate how the property can be used in the load() function). Otherwise, a polyfill script named excanvas.js will be loaded to add missing canvas functionality for Internet Explorer versions prior to 9. Once excanvas.js is loaded the myCustomScript.js script will be loaded. Because Modernizr handles loading scripts, you can also use it in creative ways. For example, you can use it to load local scripts when a 3rd party Content Delivery Network (CDN) such as one provided by Google or Microsoft is unavailable for whatever reason. The Modernizr documentation provides the following example that demonstrates the process for providing a local fallback for jQuery when a CDN is down:   Modernizr.load([ { load: '//ajax.googleapis.com/ajax/libs/jquery/1.6.4/jquery.js', complete: function () { if (!window.jQuery) { Modernizr.load('js/libs/jquery-1.6.4.min.js'); } } }, { // This will wait for the fallback to load and // execute if it needs to. load: 'needs-jQuery.js' } ]); This code attempts to load jQuery from the Google CDN first. Once the script is downloaded (or if it fails) the function associated with complete will be called. The function checks to make sure that the jQuery object is available and if it’s not Modernizr is used to load a local jQuery script. After all of that occurs a script named needs-jQuery.js will be loaded. Conclusion If you’re building applications that use some of the latest and greatest features available in HTML5 and CSS3 then Modernizr is an essential tool. By using it you can reduce the amount of custom code required to test for browser features and provide graceful fallbacks or even load shim/polyfill scripts for older browsers to help fill in missing functionality. 

    Read the article

  • CodePlex Daily Summary for Thursday, March 10, 2011

    CodePlex Daily Summary for Thursday, March 10, 2011Popular ReleasesTweetSharp: TweetSharp v2.0.0: Documentation for this release may be found at http://tweetsharp.codeplex.com/wikipage?title=UserGuide&referringTitle=Documentation. Beta ChangesAdded user streams support Serialization is not attempted for Twitter 5xx errors Fixes based on feedback Third Party Library VersionsHammock v1.2.0: http://hammock.codeplex.com Json.NET 4.0 Release 1: http://json.codeplex.comSharePoint Field Groups To Users: GroupsToUsers Release 1.0: SharePoint "Groups to Users" is a custom field that displays two separate drop-down lists. The first drop-down populates with all SharePoint Groups from the current web. By selecting a particular group the second drop-down list gets populated with all Users within the selected SharePoint group.DirectQ: Release 1.8.7 (RC2): More fixes and improvements. Note for multiplayer - you may need to set r_waterwarp to 0 or 2 before connecting to a server, otherwise you will get a "Mod_PointInLeaf: bad model" error and not be able to connect. You can set it back to 1 after you connect, of course. This only came to light after releasing, and will be fixed in the next one.Microsoft All-In-One Code Framework: Visual Studio 2008 Code Samples 2011-03-09: Code samples for Visual Studio 2008Office Web.UI: Version 2.4: After having lost all modifications done for 2.3. I finally did it again... Have a look at http://www.officewebui.com/change-log Also, the documentation continues to grow... http://www.officewebui.com/category/kb ThanksmyCollections: Version 1.3: New in version 1.3 : Added Editor management for Books Added Amazon API for Books Us, Fr, De Added Amazon Us, Fr, De for Movies Added The MovieDB for Fr and De Added Author for Books Added Editor and Platform for Games Added Amazon Us, De for Games Added Studio for XXX Added Background for XXX Bug fixing with Softonic API Bug fixing with IMDB UI improvement Removed GraceNote Added Amazon Us,Fr, De for Series Added TVDB Fr and De for Series Added Tracks for Musi...Facebook Graph Toolkit: Facebook Graph Toolkit 1.1: Version 1.1 (8 Mar 2011)new Dialog class for redirecting users to Facebook dialogs new Async publishing methods new Check for Extended Permissions option fixed bug: inappropiate condition of redirecting to login in Api class fixed bug: IframeRedirect method not workingpatterns & practices : Composite Services: Composite Services Guidance - CTP2: This is the second CTP of the p&p Composite Service Guidance.Python Tools for Visual Studio: 1.0 Beta 1: Beta 1You can't install IronPython Tools for Visual Studio side-by-side with Python Tools for Visual Studio. A race condition sometimes causes local MPI debugging to miss breakpoints. When MPI jobs on a cluster fail they don’t get cleaned up correctly, which can cause debugging to stall because the associated MPI job is stuck in the queue. The "Threads" view has a race condition which can cause it not to display properly at times. VS2010 shortcuts that are pinned to the taskbar are so...DotNetAge -a lightweight Mvc jQuery CMS: DotNetAge 2: What is new in DotNetAge 2.0 ? Completely update DJME to DJME2, enhance user experience ,more beautiful and more interactively visit DJME project home to lean more about DJME http://www.dotnetage.com/sites/home/djme.html A new widget engine has came! Faster and easiler. Runtime performance enhanced. SEO enhanced. UI Designer enhanced. A new web resources explorer. Page manager enhanced. BlogML supports added that allows you import/export your blog data to/from dotnetage publishi...Kooboo CMS: Kooboo CMS 3.0 Beta: Files in this downloadkooboo_CMS.zip: The kooboo application files Content_DBProvider.zip: Additional content database implementation of MSSQL,SQLCE, RavenDB and MongoDB. Default is XML based database. To use them, copy the related dlls into web root bin folder and remove old content provider dlls. Content provider has the name like "Kooboo.CMS.Content.Persistence.SQLServer.dll" View_Engines.zip: Supports of Razor, webform and NVelocity view engine. Copy the dlls into web root bin folder t...ASP.NET MVC Project Awesome, jQuery Ajax helpers (controls): 1.7.2: A rich set of helpers (controls) that you can use to build highly responsive and interactive Ajax-enabled Web applications. These helpers include Autocomplete, AjaxDropdown, Lookup, Confirm Dialog, Popup Form, Popup and Pager added fullscreen for the popup and popupformIronPython: 2.7 Release Candidate 2: On behalf of the IronPython team, I am pleased to announce IronPython 2.7 Release Candidate 2. The releases contains a few minor bug fixes, including a working webbrowser module. Please see the release notes for 61395 for what was fixed in previous releases.LINQ to Twitter: LINQ to Twitter Beta v2.0.20: Mono 2.8, Silverlight, OAuth, 100% Twitter API coverage, streaming, extensibility via Raw Queries, and added documentation.Minemapper: Minemapper v0.1.6: Once again supports biomes, thanks to an updated Minecraft Biome Extractor, which added support for the new Minecraft beta v1.3 map format. Updated mcmap to support new biome format.Sandcastle Help File Builder: SHFB v1.9.3.0 Release: This release supports the Sandcastle June 2010 Release (v2.6.10621.1). It includes full support for generating, installing, and removing MS Help Viewer files. This new release is compiled under .NET 4.0, supports Visual Studio 2010 solutions and projects as documentation sources, and adds support for projects targeting the Silverlight Framework. This release uses the Sandcastle Guided Installation package used by Sandcastle Styles. Download and extract to a folder and then run SandcastleI...AutoLoL: AutoLoL v1.6.4: It is now possible to run the clicker anyway when it can't detect the Masteries Window Fixed a critical bug in the open file dialog Removed the resize button Some UI changes 3D camera movement is now more intuitive (Trackball rotation) When an error occurs on the clicker it will attempt to focus AutoLoLYAF.NET (aka Yet Another Forum.NET): v1.9.5.5 RTW: YAF v1.9.5.5 RTM (Date: 3/4/2011 Rev: 4742) Official Discussion Thread here: http://forum.yetanotherforum.net/yaf_postsm47149_v1-9-5-5-RTW--Date-3-4-2011-Rev-4742.aspx Changes in v1.9.5.5 Rev. #4661 - Added "Copy" function to forum administration -- Now instead of having to manually re-enter all the access masks, etc, you can just duplicate an existing forum and modify after the fact. Rev. #4642 - New Setting to Enable/Disable Last Unread posts links Rev. #4641 - Added Arabic Language t...Snippet Designer: Snippet Designer 1.3.1: Snippet Designer 1.3.1 for Visual Studio 2010This is a bug fix release. Change logFixed bug where Snippet Designer would fail if you had the most recent Productivity Power Tools installed Fixed bug where "Export as Snippet" was failing in non-english locales Fixed bug where opening a new .snippet file would fail in non-english localesChiave File Encryption: Chiave 1.0: Final Relase for Chave 1.0 Stable: Application for file encryption and decryption using 512 Bit rijndael encyrption algorithm with simple to use UI. Its written in C# and compiled in .Net version 3.5. It incorporates features of Windows 7 like Jumplists, Taskbar progress and Aero Glass. Now with added support to Windows XP! Change Log from 0.9.2 to 1.0: ==================== Added: > Added Icon Overlay for Windows 7 Taskbar Icon. >Added Thumbnail Toolbar buttons to make the navigation easier...New ProjectsAll2Iso: Convert any disk image format to ISO. Actually it can only convert from BIN. Any help is appreciated.Asset Management by Joko for GENCPROS: This is my initial test project using codeplex storageAxvius: Axvius' core C# API library. Includes, Now, a class for overriding the system clock; especially useful for unit tests.Collision Avoidance Simulator: The vertex buff er, in conjunction with the spatial con guration of human models, a particle system and a reduced set of rules are processed in order to obtain a dynamic knowledge base for collision avoidance calculations. Developed in C++.Configuring role link in Biztalk 2009: Configuring role link in Biztalk 2009CrazySnake: Crazy Snake é o famoso jogo da cobra, esse em sua versão tanto para windows, quanto para windows phone 7dIRca WP7 IRC Client: IRC client with possible SL/WPF ports. Utilizes native tcp sockets until the communication layer from MS solidifies. Basically put, this project would not exist without the work of some wp7 hackers. Pip pip old boys.DoanVienProject: Ðây là porject qu?n lý doàn viênDynamics AX Build Scripts: Sharing build scripts for Dynamics AX integration with source control, focused on Team Foundation Server (TFS)EPiServer CMS ElencySolutions.MultipleProperty: The MultipleProperty classes are for use in EPiServer CMS 6 and provide an easy way for developers to build complex custom properties that comprise of other EPiServer custom properties. Feriados Móveis Brasil: This project aim to calculate the holidays in Brazil who is based on catholic dates. The main holiday is the Easter Sunday and the other holidays are calculated based on that date. Cálculo de feriados móveis para o Brasil baseados nas datas festivas católicas.flyskynet: myselft projectGriffTom: GriffTomImage Resizer (????????): ??????????????????,????????????????。?????jpg??。 ??????,????????????。iPray: Islamic Prayer Software.Japanese Learners & Enthusiasts Kanji Project: Help create games, puzzles, and exercises to assist learners of Japanese to master Kanji comprehension. Games/etc. will be written in C#, jQuery and/or Silverlight for ASP.NET MVC 3 Razor. Initial goal is for a user of the site to master grade level 1 Kanji (first 80 Kanji).MailChimp Amazon Simple Email Service .NET Wrapper: A .NET 4 wrapper for MailChimp's Amazon Simple Email Service. It's developed in C# using Hammock.NGuice: .NET????Guice???????????。???.NET?????????,?Guice?.NET??????????。???????:http://code.google.com/p/google-guice/Rubrica Persone: Libreria che contiene gli oggetti e le form per la gestione di una rubrica di persone, facilmente integrabile in altre applicazioni.SCCM Client Center Integration Pack for Opalis: "SCCM Client Center Integration Pack for Opalis" is an System Center Opalis Integration Pack to manage and orchestrate System Center Configuration Manager (SCCM) 2007 Agents from Opalis workflows.Sugar-free programming: I like to think about breadth or depth developer, or Mort, Elvis, or Einstein developer stereotypes, as roles we could play accordingly to the task at hand…see more: http://blogs.msdn.com/b/marcod/archive/2011/03/01/sugarfreecs1.aspxTest Project 1: This is test project siteTestZoner: TestZoneTextBookReader: ???????????????????????,??????????,??????! ??.net 2.0uSiteBuilder: uSiteBuilder is a framework made for .NET developers to simplify, speedup and take Umbraco development to next level. Aim of this framework is to reduce developer interaction with Umbraco back-end (browser based development), to create Umbraco websites in a more .NET way...VinculacionMicrosoft: Vinculacion Microsoft is a project for distributing Dreamsparks and Faculty Connection codes to students and professors. It is developed in ASP .Net and designed for Universities in Mexico interested in the different benefits that Microsoft has for them. Vio: Vio is an application for Sharetronix Based websites. Allowing users to connect to their community via their Windows Desktop.whatsnew.exe a command line utility to find new files: whatsnew.exe is a command line utility that lists the files created (new files) in a given number of days. whatsnew.exe 's syntax is very simple: whatsnew path numberofdays Also whatsnew supports other options like HTML or XML output, hyperlinked outputs and more.

    Read the article

  • High apache load but little traffic logged

    - by nrambeck
    I recently installed Varnish to sit in front of Apache on a dedicated server running a single site. It appears to be working well, but the load on Apache is still very high. What doesn't make sense is that the Apache access log shows almost no traffic getting past Varnish. When I tail the apache log I see about 1-3 hits per second come through. Here is what the load on Apache looks like : USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND apache 13834 8.1 1.0 107716 34164 ? S 08:24 0:02 /usr/sbin/httpd apache 13835 8.1 1.0 107716 33856 ? S 08:24 0:02 /usr/sbin/httpd apache 11483 7.9 0.9 105916 30788 ? S 08:23 0:06 /usr/sbin/httpd apache 12255 7.5 1.0 107476 33312 ? S 08:24 0:04 /usr/sbin/httpd apache 9340 7.2 1.1 107732 34916 ? R 08:23 0:09 /usr/sbin/httpd apache 12029 6.8 0.9 106908 30416 ? S 08:24 0:04 /usr/sbin/httpd apache 11577 6.7 1.0 107192 34180 ? S 08:24 0:05 /usr/sbin/httpd apache 11486 6.6 1.0 106176 33112 ? S 08:23 0:05 /usr/sbin/httpd apache 11796 6.4 1.0 106936 31916 ? S 08:24 0:04 /usr/sbin/httpd apache 13815 6.3 1.0 107988 34464 ? S 08:24 0:02 /usr/sbin/httpd apache 18089 6.3 1.3 107444 43212 ? S 08:11 0:52 /usr/sbin/httpd apache 11797 5.9 1.0 107716 34580 ? S 08:24 0:04 /usr/sbin/httpd apache 7655 5.9 0.0 0 0 ? Z 08:22 0:09 [httpd] <defunct> mysql 8033 5.9 6.2 318240 199512 ? Sl May14 352:34 /usr/libexec/mysqld --basedir=/usr --datadir=/var/lib/mysql --user=mysql --pid-file=/va apache 11488 5.8 0.9 106924 31632 ? S 08:23 0:04 /usr/sbin/httpd apache 9375 5.7 1.1 106956 35552 ? S 08:23 0:07 /usr/sbin/httpd apache 3551 5.6 1.1 106956 36140 ? S 08:20 0:14 /usr/sbin/httpd apache 7657 5.6 1.0 106968 32472 ? S 08:22 0:09 /usr/sbin/httpd apache 11433 5.6 1.0 107716 34396 ? S 08:23 0:04 /usr/sbin/httpd apache 5505 5.5 1.1 106944 34924 ? S 08:21 0:12 /usr/sbin/httpd apache 7172 5.3 1.1 106972 35368 ? S 08:22 0:09 /usr/sbin/httpd apache 10088 5.2 0.9 106160 31240 ? S 08:23 0:04 /usr/sbin/httpd apache 7656 5.1 1.0 106436 34388 ? S 08:22 0:08 /usr/sbin/httpd apache 3468 5.0 1.1 107716 35968 ? S 08:20 0:13 /usr/sbin/httpd apache 14242 4.8 1.0 107728 33032 ? S 08:25 0:00 /usr/sbin/httpd apache 3578 4.8 1.1 107988 35964 ? S 08:20 0:12 /usr/sbin/httpd apache 28192 4.8 1.2 106944 38060 ? S 08:17 0:23 /usr/sbin/httpd apache 3277 4.6 1.1 106956 35688 ? S 08:20 0:13 /usr/sbin/httpd apache 15434 3.7 0.7 106908 24684 ? S 08:25 0:00 /usr/sbin/httpd There is a default apache log and then one other VirtualHost log setup. I'm concerned that Apache is handling some kind of traffic that is not being logged. Is that possible? And is there anything I can do to capture that traffic?

    Read the article

  • FFSERVER - streaming an ASF video as Webm output

    - by Emmanuel Brunet
    I'm trying to stream an IP webcam ASF live stream to a ffserver to output a webm video format. The server starts successfully but the ffserver commands used to feed the ffserver fails and generates a core dump. Environment Debian 7.5 ffmpeg 2.2 Input stream $ ffprobe http://account:password@webcam/videostream.asf Input #0, asf, from 'http://admin:alpha1237@webcam/videostream.asf': Duration: N/A, start: 0.000000, bitrate: 32 kb/s Stream #0:0: Video: mjpeg (MJPG / 0x47504A4D), yuvj422p(pc), 640x480, 25 tbr, 1k tbn, 1k tbc Stream #0:1: Audio: adpcm_ima_wav ([17][0][0][0] / 0x0011), 8000 Hz, 1 channels, s16p, 32 kb/s ffserver configuration my ffserver configuration is : Port 8091 RTSPPort 554 BindAddress 192.168.1.62 MaxHTTPConnections 1000 MaxClients 100 MaxBandwidth 1000 CustomLog - <Feed webcam.ffm> File /tmp/webcam.ffm FileMaxSize 500M ACL allow localhost ACL allow 192.168.0.0 192.168.255.255 </Feed> <Stream webcam.webm> # Output stream URL definition Feed webcam.ffm # Feed from which to receive video Format webm # Audio settings AudioCodec vorbis AudioBitRate 64 # Audio bitrate # Video settings VideoCodec libvpx VideoSize 640x480 # Video resolution VideoFrameRate 25 # Video FPS AVOptionVideo flags +global_header # Parameters passed to encoder # (same as ffmpeg command-line parameters) AVOptionVideo cpu-used 0 AVOptionVideo qmin 10 AVOptionVideo qmax 42 AVOptionVideo quality good AVOptionAudio flags +global_header PreRoll 15 StartSendOnKey # VideoBitRate 32 # Video bitrate </Stream> <Stream status.html> Format status # Only allow local people to get the status ACL allow localhost ACL allow 192.168.0.0 192.168.255.255 </Stream> ffmpeg feed I run the following command that fails $ ffmpeg -i http://account:password@webcam/videostream.asf http://192.168.1.62:8091/webcam.ffm http://192.168.1.62:8091/webcam.ffm Input #0, asf, from 'http://account:password@webcam/videostream.asf': Duration: N/A, start: 0.000000, bitrate: 32 kb/s Stream #0:0: Video: mjpeg (MJPG / 0x47504A4D), yuvj422p(pc), 640x480, 25 tbr, 1k tbn, 1k tbc Stream #0:1: Audio: adpcm_ima_wav ([17][0][0][0] / 0x0011), 8000 Hz, mono, s16p, 32 kb/s [swscaler @ 0x36a80c0] deprecated pixel format used, make sure you did set range correctly Segmentation fault I tryed $ ffmpeg -i http://account:password@webcam/videostream.asf -pix_fmt yuv420p http://192.168.1.62:8091/webcam.ffm But it raises the same error. Thanks for your help Edit For an easy testing (I thought), I tried to publish the whole ASF stream as is, meaning connecting the ASF webcam output stream to the ffserver that outputs ASF format too. And thus with mirrored encoding so I changed the ffserver configuration to ... <Stream webcam.asf> Feed webcam.ffm Format asf VideoFrameRate 25 VideoSize 640X480 VideoBitRate 256 VideoBufferSize 1000 VideoGopSize 30 AudioBitRate 32 StartSendOnKey </Stream> ... And the output is now : Input #0, asf, from 'http://admin:alpha1237@webcam/videostream.asf': Duration: N/A, start: 0.000000, bitrate: 32 kb/s Stream #0:0: Video: mjpeg (MJPG / 0x47504A4D), yuvj422p(pc), 640x480, 1k tbr, 1k tbn, 1k tbc Stream #0:1: Audio: adpcm_ima_wav ([17][0][0][0] / 0x0011), 8000 Hz, mono, s16p, 32 kb/s [swscaler @ 0x3d620c0] deprecated pixel format used, make sure you did set range correctly Output #0, ffm, to 'http://192.168.1.62:8091/webcam.ffm': Metadata: creation_time : now encoder : Lavf55.40.100 Stream #0:0: Audio: wmav2, 22050 Hz, mono, fltp, 32 kb/s Metadata: encoder : Lavc55.64.100 wmav2 Stream #0:1: Video: msmpeg4v3 (msmpeg4), yuv420p, 640x480, q=2-31, 256 kb/s, 1k fps, 1000k tbn, 1k tbc Metadata: Stream mapping: Stream #0:1 -> #0:0 (adpcm_ima_wav -> wmav2) Stream #0:0 -> #0:1 (mjpeg -> msmpeg4) Press [q] to stop, [?] for help Segmentation fault I can't even forward the stream.

    Read the article

  • Locating Rogue Perl Script

    - by Gary Garside
    I've been trying to source the location of a perl script which is causing havoc on a server which i control. I'm also trying to find out exactly how this script was installed on the server - my best guess is through a wordpress exploit. The server is a basic web setup running Ubuntu 9.04, Apache and MySQL. I use IPTables for firewall, the site runs around 20 sites and the load never really creeps above 0.7. From what i can see the script is making outbound connection to other servers (most likely trying to brute force entry). Here is a top dump of one of the processes: PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 22569 www-data 20 0 22784 3216 780 R 100 0.2 47:00.60 perl The command the process is running is /usr/sbin/sshd . I've tried to find an exact file name but im having no luck... i've ran a lsof -p PID and here is the output: COMMAND PID USER FD TYPE DEVICE SIZE NODE NAME perl 22569 www-data cwd DIR 8,6 4096 2 / perl 22569 www-data rtd DIR 8,6 4096 2 / perl 22569 www-data txt REG 8,6 10336 162220 /usr/bin/perl perl 22569 www-data mem REG 8,6 26936 170219 /usr/lib/perl/5.10.0/auto/Socket/Socket.so perl 22569 www-data mem REG 8,6 22808 170214 /usr/lib/perl/5.10.0/auto/IO/IO.so perl 22569 www-data mem REG 8,6 39112 145112 /lib/libcrypt-2.9.so perl 22569 www-data mem REG 8,6 1502512 145124 /lib/libc-2.9.so perl 22569 www-data mem REG 8,6 130151 145113 /lib/libpthread-2.9.so perl 22569 www-data mem REG 8,6 542928 145122 /lib/libm-2.9.so perl 22569 www-data mem REG 8,6 14608 145125 /lib/libdl-2.9.so perl 22569 www-data mem REG 8,6 1503704 162222 /usr/lib/libperl.so.5.10.0 perl 22569 www-data mem REG 8,6 135680 145116 /lib/ld-2.9.so perl 22569 www-data 0r FIFO 0,6 157216 pipe perl 22569 www-data 1w FIFO 0,6 197642 pipe perl 22569 www-data 2w FIFO 0,6 197642 pipe perl 22569 www-data 3w FIFO 0,6 197642 pipe perl 22569 www-data 4u IPv4 383991 TCP outsidesoftware.com:56869->server12.34.56.78.live-servers.net:www (ESTABLISHED) My gut feeling is outsidesoftware.com is also under attacK? Or possibly being used as a tunnel. I've managed to find a number of rouge files in /tmp and /var/tmp, here is a brief output of one of these files: #!/usr/bin/perl # this spreader is coded by xdh # xdh@xxxxxxxxxxx # only for testing... my @nickname = ("vn"); my $nick = $nickname[rand scalar @nickname]; my $ircname = $nickname[rand scalar @nickname]; #system("kill -9 `ps ax |grep httpdse |grep -v grep|awk '{print $1;}'`"); my $processo = '/usr/sbin/sshd'; The full file contents can be viewed here: http://pastebin.com/yenFRrGP Im trying to achieve a couple of things here... Firstly i need to stop these processes from running. Either by disabling outbound SSH or any IP Tables rules etc... these scripts have been running for around 36 hours now and my main concern is to stop these things running and respawning by themselves. Secondly i need to try and source where and how these scripts have been installed. If anybody has any advise on what to look for in access logs or anything else i would be really grateful. Thanks in advance

    Read the article

  • Useful software for netbook?

    - by Moayad Mardini
    I'm looking for recommendations of good software that are particularly useful for netbooks. Software that run great on small screens and low CPU/RAM requirments. I'll start off with the following : Operating Systems: Ubuntu Netbook Remix. Easy Peasy: A fork of Ubuntu Netbook Remix that was once called UBuntu EEE. It isn't just for eeePCs though. Definitely worth a look if vanilla Netbook Remix isn't cutting it. (MarkM) Damn Small Linux (Source) Windows 7: With trimming the installation or compressing the Windows directory to fit on an 8GB SSD. (Will Eddins) nLite: A utility to install a lightweight version of Windows XP without the unnecessary components (like Media Player, Internet Explorer, Outlook Express, MSN Explorer, Messenger...). Utilites: TouchFreeze: To disable the touch pad while typing (Source) InSSIDer: Not only does it make it easier to find and keep a wireless connection, but it turns a netbook into the perfect mobile tool for troubleshooting wireless networks. (phenry) AltMove: Adds more functionality to your mouse for interacting with windows. (Rob) ASUS Font Resizer Utility and other tools by ASUS, specific to ASUS Eee PC series. Internet: Run FileZilla FTP client for a small screen : You can hide a lot of FileZilla's interface parts in the View menu, even the directory trees. Go into Settings = Interface and move the message log next to the transfer queue, if you haven't hidden them both or you want to see them. Select a theme with 16x16 icons. (Source) IDEs and Text Editors: Best lightweight IDE/Text Editor: A question on Stack Overflow that has many good suggestions of IDEs and general text editors for programmers. What’s a good linux C/C++ IDE for a low-res screen?: IDEs for Linux-powered netbooks. Online tools: Dropbox: Since the Netbook has limited disk space, you would like to use Cloud Apps like Dropbox and Ubuntu One so that you don't run out of space especially if you are on a holiday. Later when you go back to your desktop with big hard disk,you can take out the files from your dropbox repo. (Manish Sinha) Google products: like Docs, Calendar and Reader (aviraldg) Web sites and software lists: Netbookfiles.com: Netbook specific software downloads. Software Apps to Maximise your Netbook Battery Power: Netbooks are known for their portability. Not only are they small and lightweight but with their increased power efficiency, batteries can last much longer than conventional laptops. This also means you no longer have to carry a power adapter with you! Several brands emphasis the longevity of the battery as a strong selling point, and for those people who travel a lot, it sure is. Free Must-Have Netbook Apps: Finding software for netbooks can present challenges due to limited hard drive space, processor power, RAM, and screen real-estate. That doesn't mean you have to do without essential programs. The apps below cover all the bases -- entertainment, productivity, security, and communication -- without compromising on performance or usability. Best of all, they're free! Useful Netbook Software: With short battery lives and small resolution screens Netbooks, unlike many other computers on the market, could so with some specific software for their use. Now, not all of those I’ve found are specifically designed for Netbooks, but all are relevant. And they’re designed for Windows XP. The question is community wiki, so feel free to edit it. Updated, thank you all for suggestions.

    Read the article

  • Squid w/ SquidGuard fails w/ "Too few redirector processes are running"

    - by DKNUCKLES
    I'm trying to implement a Squid proxy in a quick and easy fashion and I'm receiving some errors I have been unable to resolve. The box is a pre-made appliance, however it seems to fail on launch.The following is the cache.log file when I attempt to launch the squid service. 2012/11/18 22:14:29| Starting Squid Cache version 3.0.STABLE20-20091201 for i686 -pc-linux-gnu... 2012/11/18 22:14:29| Process ID 12647 2012/11/18 22:14:29| With 1024 file descriptors available 2012/11/18 22:14:29| Performing DNS Tests... 2012/11/18 22:14:29| Successful DNS name lookup tests... 2012/11/18 22:14:29| DNS Socket created at 0.0.0.0, port 40513, FD 8 2012/11/18 22:14:29| Adding nameserver 192.168.0.78 from /etc/resolv.conf 2012/11/18 22:14:29| Adding nameserver 8.8.8.8 from /etc/resolv.conf 2012/11/18 22:14:29| helperOpenServers: Starting 5/5 'bin' processes 2012/11/18 22:14:29| ipcCreate: /opt/squidguard/bin: (13) Permission denied 2012/11/18 22:14:29| ipcCreate: /opt/squidguard/bin: (13) Permission denied 2012/11/18 22:14:29| ipcCreate: /opt/squidguard/bin: (13) Permission denied 2012/11/18 22:14:29| ipcCreate: /opt/squidguard/bin: (13) Permission denied 2012/11/18 22:14:29| ipcCreate: /opt/squidguard/bin: (13) Permission denied 2012/11/18 22:14:29| helperOpenServers: Starting 5/5 'squid-auth.pl' processes 2012/11/18 22:14:29| User-Agent logging is disabled. 2012/11/18 22:14:29| Referer logging is disabled. 2012/11/18 22:14:29| Unlinkd pipe opened on FD 23 2012/11/18 22:14:29| Swap maxSize 10240000 + 8192 KB, estimated 788322 objects 2012/11/18 22:14:29| Target number of buckets: 39416 2012/11/18 22:14:29| Using 65536 Store buckets 2012/11/18 22:14:29| Max Mem size: 8192 KB 2012/11/18 22:14:29| Max Swap size: 10240000 KB 2012/11/18 22:14:29| Version 1 of swap file with LFS support detected... 2012/11/18 22:14:29| Rebuilding storage in /opt/squid3/var/cache (DIRTY) 2012/11/18 22:14:29| Using Least Load store dir selection 2012/11/18 22:14:29| Set Current Directory to /opt/squid3/var/cache 2012/11/18 22:14:29| Loaded Icons. 2012/11/18 22:14:29| Accepting HTTP connections at 10.0.0.6, port 3128, FD 25. 2012/11/18 22:14:29| Accepting ICP messages at 0.0.0.0, port 3130, FD 26. 2012/11/18 22:14:29| HTCP Disabled. 2012/11/18 22:14:29| Ready to serve requests. 2012/11/18 22:14:29| Done reading /opt/squid3/var/cache swaplog (0 entries) 2012/11/18 22:14:29| Finished rebuilding storage from disk. 2012/11/18 22:14:29| 0 Entries scanned 2012/11/18 22:14:29| 0 Invalid entries. 2012/11/18 22:14:29| 0 With invalid flags. 2012/11/18 22:14:29| 0 Objects loaded. 2012/11/18 22:14:29| 0 Objects expired. 2012/11/18 22:14:29| 0 Objects cancelled. 2012/11/18 22:14:29| 0 Duplicate URLs purged. 2012/11/18 22:14:29| 0 Swapfile clashes avoided. 2012/11/18 22:14:29| Took 0.02 seconds ( 0.00 objects/sec). 2012/11/18 22:14:29| Beginning Validation Procedure 2012/11/18 22:14:29| WARNING: redirector #1 (FD 9) exited 2012/11/18 22:14:29| WARNING: redirector #2 (FD 10) exited 2012/11/18 22:14:29| WARNING: redirector #3 (FD 11) exited 2012/11/18 22:14:29| WARNING: redirector #4 (FD 12) exited 2012/11/18 22:14:29| Too few redirector processes are running FATAL: The redirector helpers are crashing too rapidly, need help! Squid Cache (Version 3.0.STABLE20-20091201): Terminated abnormally. CPU Usage: 0.112 seconds = 0.032 user + 0.080 sys Maximum Resident Size: 0 KB Page faults with physical i/o: 0 Memory usage for squid via mallinfo(): total space in arena: 2944 KB Ordinary blocks: 2857 KB 6 blks Small blocks: 0 KB 0 blks Holding blocks: 1772 KB 8 blks Free Small blocks: 0 KB Free Ordinary blocks: 86 KB Total in use: 4629 KB 157% Total free: 86 KB 3% The "permission denied" area is where I have been focusing my attention with no luck. The following is what I've tried. Chmod'ing the /opt/squidguard/bin folder to 777 Changing the user that squidguard runs under to root / nobody / www-data / squid3 Tried changing ownership of the /opt/squidguard/bin folder to all names listed above after assigning that user to run with squid. Any help with this would be greatly appreciated.

    Read the article

  • Ubuntu server random hangups.

    - by Ebbe
    Hello all. this is my first post to this forum which I found through the superb podcast "It Conversations" from StackOverFlow. I am quite in my role as server administrator for an exhibition center in London. Basically we have a central file and sql server to which roughly 40 stations connects to to upload/download data used/captured by a set of applications. Over the last weeks we have experienced a few random hangups to our applications, and as it always happen to multiple applications simultaneously I do not believe that the applications are the source of the problem. We also monitor the network using Dartware Intermapper which indicates that all switches and stations on the network has been reachable during the downtime. Thus, its all pointing to the server. I have been looking through all log files I can think of and the only thing so far that I have found suspicious is the following lines in the syslog which are from the time of one of the hangups: Feb 6 17:14:27 es named[5582]: client 127.0.0.1#33721: RFC 1918 response from Internet for 150.0.168.192.in-addr.arpa Feb 6 17:14:40 es named[5582]: client 127.0.0.1#32899: RFC 1918 response from Internet for 152.0.168.192.in-addr.arpa Feb 6 17:15:01 es /USR/SBIN/CRON[1956]: (es) CMD (/home/es/apps/es/bin/es_checksum.sh) Feb 6 17:16:06 es /USR/SBIN/CRON[2031]: (es) CMD (/home/es/apps/es/bin/es_checksum.sh) Feb 6 17:21:00 es named[5582]: *** POKED TIMER *** Feb 6 17:21:00 es last message repeated 2 times Feb 6 17:21:07 es named[5582]: client 127.0.0.1#44194: RFC 1918 response from Internet for 143.0.168.192.in-addr.arpa Feb 6 17:21:12 es named[5582]: client 127.0.0.1#59004: RFC 1918 response from Internet for 164.0.168.192.in-addr.arpa I find a few lines of interesting lines here: 1) "RFC 1918 response from Internet for 150.1.168.192.in-addr.arpa". I see this a lot in the syslog. And basically everytime I do a nslookup for any of the computers in the cluster I get a new similar line in the syslog. I understand from google that this has to do with reverse lookup problems. But I do not know how that could effect the systems. Lets say that one of these lines appear every time one of the userstations connects to the server, which may happen several times a second. Could this possible cause a hangup of the entire server? 2) POKED TIMER, I have googled this quite a lot, but not found an explaination that I can relate to. What does this mean? 3) The timestamps, it seems like the entire server has stopped responding for several minutes. Normally there are many printouts to the syslog per minute on this server. Furthermore the CRON job is set to run once every minute. Which according to the log, hasent happened here. OS: Ubuntu 8.04 Kernel: Linux 2.6.24-24-server x86_64 GNU/Linux. Hardware: Dell R710, RAID1, CPU: 2x XEON E5530. 16GB Memory. Average load is very low, and memory should not be a problem. Please let me know if you need any additional information. Best wishes, Ebbe

    Read the article

  • apache+mod_wsgi configuration for django project(s) on a quad core

    - by Stefano
    I've been experiment quite some time with a "typical" django setting upon nginx+apache2+mod_wsgi+memcached(+postgresql) (reading the doc and some questions on SO and SF, see comments) Since I'm still unsatisfied with the behavior (definitely because of some bad misconfiguration on my part) I would like to know what a good configuration would look like with these hypotesis: Quad-Core Xeon 2.8GHz 8 gigs memory several django projects (anything special related to this?) These are excerpts form my current confs: apache2 SetEnv VHOST null #WSGIPythonOptimize 2 <VirtualHost *:8082> ServerName subdomain.domain.com ServerAlias www.domain.com SetEnv VHOST subdomain.domain AddDefaultCharset UTF-8 ServerSignature Off LogFormat "%{X-Real-IP}i %u %t \"%r\" %>s %b \"%{Referer}i\" \"%{User-agent}i\"" custom ErrorLog /home/project1/var/logs/apache_error.log CustomLog /home/project1/var/logs/apache_access.log custom AllowEncodedSlashes On WSGIDaemonProcess subdomain.domain user=www-data group=www-data threads=25 WSGIScriptAlias / /home/project1/project/wsgi.py WSGIProcessGroup %{ENV:VHOST} </VirtualHost> wsgi.py import os import sys # setting all the right paths.... _realpath = os.path.realpath(os.path.dirname(__file__)) _public_html = os.path.normpath(os.path.join(_realpath, '../')) sys.path.append(_realpath) sys.path.append(os.path.normpath(os.path.join(_realpath, 'apps'))) sys.path.append(os.path.normpath(_public_html)) sys.path.append(os.path.normpath(os.path.join(_public_html, 'libs'))) sys.path.append(os.path.normpath(os.path.join(_public_html, 'django'))) os.environ['DJANGO_SETTINGS_MODULE'] = 'settings' import django.core.handlers.wsgi _application = django.core.handlers.wsgi.WSGIHandler() def application(environ, start_response): """ Launches django passing over some environment (domain name) settings """ application_group = environ['mod_wsgi.application_group'] """ wsgi application group is required. It's also used to generate the HOST.DOMAIN.TLD:PORT parameters to pass over """ assert application_group fields = application_group.replace('|', '').split(':') server_name = fields[0] os.environ['WSGI_APPLICATION_GROUP'] = application_group os.environ['WSGI_SERVER_NAME'] = server_name if len(fields) > 1 : os.environ['WSGI_PORT'] = fields[1] splitted = server_name.rsplit('.', 2) assert splitted >= 2 splited.reverse() if len(splitted) > 0 : os.environ['WSGI_TLD'] = splitted[0] if len(splitted) > 1 : os.environ['WSGI_DOMAIN'] = splitted[1] if len(splitted) > 2 : os.environ['WSGI_HOST'] = splitted[2] return _application(environ, start_response)` folder structure in case it matters (slightly shortened actually) /home/www-data/projectN/var/logs /project (contains manage.py, wsgi.py, settings.py) /project/apps (all the project ups are here) /django /libs Please forgive me in advance if I overlooked something obvious. My main question is about the apache2 wsgi settings. Are those fine? Is 25 threads an /ok/ number with a quad core for one only django project? Is it still ok with several django projects on different virtual hosts? Should I specify 'process'? Any other directive which I should add? Is there anything really bad in the wsgi.py file? I've been reading about potential issues with the standard wsgi.py file, should I switch to that? Or.. should this conf just be running fine, and I should look for issues somewhere else? So, what do I mean by "unsatisfied": well, I often get quite high CPU WAIT; but what is worse, is that relatively often apache2 gets stuck. It just does not answer anymore, and has to be restarted. I have setup a monit to take care of that, but it ain't a real solution. I have been wondering if it's an issue with the database access (postgresql) under heavy load, but even if it was, why would the apache2 processes get stuck? Beside these two issues, performance is overall great. I even tried New Relic and got very good average results.

    Read the article

  • Detecting source of memory usage on a Linux box

    - by apeace
    I have a toy Linux box with 256mb RAM running Ubuntu 10.04.1 LTS. Here is the output of free -m: total used free shared buffers cached Mem: 245 122 122 0 19 64 -/+ buffers/cache: 38 206 Swap: 511 0 511 Unless I'm reading this wrong, 122mb is being used and only 84mb of that is disk cache. Here are all processes I'm running sorted by memory usage (ps -eo pmem,pcpu,rss,vsize,args | sort -k 1 -r): %MEM %CPU RSS VSZ COMMAND 5.0 0.0 12648 633140 node /home/node/main/sites.js 1.5 0.0 3884 251736 /usr/sbin/console-kit-daemon --no-daemon 1.3 0.0 3328 77108 sshd: apeace [priv] 0.9 0.0 2344 19624 -bash 0.7 0.0 1776 23620 /sbin/init 0.6 0.0 1624 77108 sshd: apeace@pts/0 0.6 0.0 1544 9940 redis-server /etc/redis/redis.conf 0.6 0.0 1524 25848 /usr/sbin/ntpd -p /var/run/ntpd.pid -g -u 103:105 0.5 0.0 1324 119880 rsyslogd -c4 0.4 0.0 1084 49308 /usr/sbin/sshd 0.4 0.0 1028 44376 /usr/sbin/exim4 -bd -q30m 0.3 0.0 904 6876 ps -eo pmem,pcpu,rss,vsize,args 0.3 0.0 888 21124 cron 0.3 0.0 868 23472 dbus-daemon --system --fork 0.2 0.0 732 19624 -bash 0.2 0.0 628 6128 /sbin/getty -8 38400 tty1 0.2 0.0 628 16952 upstart-udev-bridge --daemon 0.2 0.0 564 16800 udevd --daemon 0.2 0.0 552 16796 udevd --daemon 0.2 0.0 548 16796 udevd --daemon 0.0 0.0 0 0 [xenwatch] 0.0 0.0 0 0 [xenbus] 0.0 0.0 0 0 [sync_supers] 0.0 0.0 0 0 [netns] 0.0 0.0 0 0 [migration/3] 0.0 0.0 0 0 [migration/2] 0.0 0.0 0 0 [migration/1] 0.0 0.0 0 0 [migration/0] 0.0 0.0 0 0 [kthreadd] 0.0 0.0 0 0 [kswapd0] 0.0 0.0 0 0 [kstriped] 0.0 0.0 0 0 [ksoftirqd/3] 0.0 0.0 0 0 [ksoftirqd/2] 0.0 0.0 0 0 [ksoftirqd/1] 0.0 0.0 0 0 [ksoftirqd/0] 0.0 0.0 0 0 [ksnapd] 0.0 0.0 0 0 [kseriod] 0.0 0.0 0 0 [kjournald] 0.0 0.0 0 0 [khvcd] 0.0 0.0 0 0 [khelper] 0.0 0.0 0 0 [kblockd/3] 0.0 0.0 0 0 [kblockd/2] 0.0 0.0 0 0 [kblockd/1] 0.0 0.0 0 0 [kblockd/0] 0.0 0.0 0 0 [flush-202:1] 0.0 0.0 0 0 [events/3] 0.0 0.0 0 0 [events/2] 0.0 0.0 0 0 [events/1] 0.0 0.0 0 0 [events/0] 0.0 0.0 0 0 [crypto/3] 0.0 0.0 0 0 [crypto/2] 0.0 0.0 0 0 [crypto/1] 0.0 0.0 0 0 [crypto/0] 0.0 0.0 0 0 [cpuset] 0.0 0.0 0 0 [bdi-default] 0.0 0.0 0 0 [async/mgr] 0.0 0.0 0 0 [aio/3] 0.0 0.0 0 0 [aio/2] 0.0 0.0 0 0 [aio/1] 0.0 0.0 0 0 [aio/0] Now, I know that ps is not the best for viewing process memory usage, but that's because it tends to report more memory than is actually being used...meaning no matter how you look at it all my processes combined shouldn't be using near 122mb, even if you account for the disk cache. What's more, memory usage is growing all the time. I've had to restart my server once a week, because once my 256mb fills up it starts swapping, which it wouldn't do just for disk cache. Shouldn't there be some way for me to see the culprit?! I'm new to server admin, so please if there's something obvious I'm overlooking point it out to me. Just for good measure, the output of cat /proc/meminfo: MemTotal: 251140 kB MemFree: 124604 kB Buffers: 20536 kB Cached: 66136 kB SwapCached: 0 kB Active: 65004 kB Inactive: 37576 kB Active(anon): 15932 kB Inactive(anon): 164 kB Active(file): 49072 kB Inactive(file): 37412 kB Unevictable: 0 kB Mlocked: 0 kB SwapTotal: 524284 kB SwapFree: 524284 kB Dirty: 8 kB Writeback: 0 kB AnonPages: 15916 kB Mapped: 10668 kB Shmem: 188 kB Slab: 18604 kB SReclaimable: 10088 kB SUnreclaim: 8516 kB KernelStack: 536 kB PageTables: 1444 kB NFS_Unstable: 0 kB Bounce: 0 kB WritebackTmp: 0 kB CommitLimit: 649852 kB Committed_AS: 64224 kB VmallocTotal: 34359738367 kB VmallocUsed: 752 kB VmallocChunk: 34359737600 kB DirectMap4k: 262144 kB DirectMap2M: 0 kB EDIT: I had misinterpreted the meaning of free -m at first. But even so: the important thing is that my OS eventually begins to use swap memory if I don't restart my server, which disk caching wouldn't do. So where do I look to see what is using all this memory?

    Read the article

  • Why do GPUs overheat?

    - by JAD
    About a year ago, I added a 9800GT (1 GB version) and a Corsair CX500 PSU to an HP M8000N computer. A few weeks ago, the HDD overheated and I decided to transfer the GPU & PSU to a new build, which consists of: i3 @ 3.3Ghz Gigabyte H61 Micro ATX Mobo 4GB RAM 500GB WD HDD DVD RW Drive Cooler Master Elite 430 Tower Once I had Win7 up and running, I installed all the essential drivers that came with the Gigabyte Mobo CD. However, whenever I tried installing the Graphics Media Accelerator driver, the computer would crash and enter an endless boot sequence on the next startup. I skipped installing this driver and installed the CD driver for the 9800GT, which by now is a year old. Everything was working fine, WEI rated my GPU at 6.6 graphics & aero performance. However, after updating my Nvidia drivers to the latest, the WEI dropped my rating to 3.3 for Aero, and 4.7 for graphics performance. Just to make sure that everything was ok, I ran Bad Company 2 on medium settings. The first few minutes ran just fine at a smooth framerate, so I dismissed this as Windows being Windows. About 6 hours later, I ran BC2 again. This time I averaged anywhere from 2-5 FPS. I checked the GPU temperature through GPU-Z, and it came back as 120C. The problem with this, is that the computer was on for six hours up to that point. Wouldn't the card have experienced a reactor core meltdown a lot sooner than that? Granted, the computer was "sleeping" some of the time, but still... The next day I took out a temperature gun and ran some tests. I would point the laser at a very specific area on the reverse side of the card (not the fan or "front"), and compare the temp reading with GPU-Z. After leaving the system on idle on idle for a few minutes, I ran BC2 twice. Here are the results: GPU-Z Reading / Temp Gun Reading / Time Null / 22.3°C / Comp is Off 53°C / 33.5°C / 1:49 78°C / 46°C / 1:53 - (First BC2 run; good framerate) 102°C / 64.6°C / 2:01 - (System is again on idle) 113°C / 64.8°C / 2:10 119°C / 71.8°C / 2:17 - (Second BC2 run; poor framerate) I should also mention that I also took a temp recording of another part of the GPU from 2:01-2:17. The temp in this area jumped from 75°C to 82.9°C in that time frame. This pretty much confirms that GPU-Z is reporting the temperature accurately, and the card is overheating. But I'd like to know why; the cars is doing nothing and still the temperature climbs at a steady rate. I thoroughly cleaned the GPU and PSU when I salvaged them from the old HP M8000N computer with a can of compressed air, dust cant be the issue. Similarly, the rest of the computer is brand new. I installed various Nvidia drivers, but no luck. It seems strange to me that a year-old card is suddenly failing on me; aren't they supposed to last at least two years? Could this be a driver issue? Is the motherboard faulty? Could the PSU be overfeeding the card on voltage? Neither case seems likely, as the CPU, RAM and otherwise the rest of the comp has worked flawlessly and has stayed well within respectable temp ranges (the i3 lingers around 50C, the HDD stays at 30C, so does the PSU). How can I pinpoint the issue?

    Read the article

  • Have I pushed the limits of my current VPS or is there room for optimization?

    - by JRameau
    I am currently on a mediatemple DV server (basic) 512mb dedicated ram, this is a CentOS based VPS with Plesk and Virtuozzo. My experience with it from day 1 has been bad and I only could sooth my server issues with several caching "Band-aids," but my sites are not as small as they were a year ago either so the issues have worsen. I have 3 Drupal installs running on separate (plesk) domains, 1 of those drupal installs is a multisite, that consists of 5-6 sites 2 of those sites are bringing in actual traffic. Those caching "Band-aids" I mentioned are APC, which seemed to help alot initially, and Drupal's Boost, which is considered a poorman's Varnish, it makes all my pages static for anonymous users. Last 30day combined estimate on Google Ananlytics: 90k visitors 260k pageviews. Issue: alot of downtime, I am continually checking if my sites are up, and lately I have been finding it down more than 3 times daily. Restarting Apache will bring it back up, for some time. I have google search every error message and looked up ways to optimize my DV server, and I am beyond stump what is my next move. Is this server bad, have I hit a impossibly low restriction such as the 12mb kernel memory barrier (kmemsize), is it on my end, do I need to optimize some more? *I have provided as much information as I can below, any help or suggestions given will be appreciated Common Error messages I see in the log: [error] (12)Cannot allocate memory: fork: Unable to fork new process [error] make_obcallback: could not import mod_python.apache.\n Traceback (most recent call last): File "/usr/lib/python2.4/site-packages/mod_python/apache.py", line 21, in ? import traceback File "/usr/lib/python2.4/traceback.py", line 3, in ? import linecache ImportError: No module named linecache [error] python_handler: no interpreter callback found. [warn-phpd] mmap cache can't open /var/www/vhosts/***/httpdocs/*** - Too many open files in system (pid ***) [alert] Child 8125 returned a Fatal error... Apache is exiting! [emerg] (43)Identifier removed: couldn't grab the accept mutex [emerg] (22)Invalid argument: couldn't release the accept mutex cat /proc/user_beancounters: Version: 2.5 uid resource held maxheld barrier limit failcnt 41548: kmemsize 4582652 5306699 12288832 13517715 21105036 lockedpages 0 0 600 600 0 privvmpages 38151 42676 229036 249036 0 shmpages 16274 16274 17237 17237 2 dummy 0 0 0 0 0 numproc 43 46 300 300 0 physpages 27260 29528 0 2147483647 0 vmguarpages 0 0 131072 2147483647 0 oomguarpages 27270 29538 131072 2147483647 0 numtcpsock 21 29 300 300 0 numflock 8 8 480 528 0 numpty 1 1 30 30 0 numsiginfo 0 1 1024 1024 0 tcpsndbuf 648440 675272 2867477 4096277 1711499 tcprcvbuf 301620 359716 2867477 4096277 0 othersockbuf 4472 4472 1433738 2662538 0 dgramrcvbuf 0 0 1433738 1433738 0 numothersock 12 12 300 300 0 dcachesize 0 0 2684271 2764800 0 numfile 3447 3496 6300 6300 3872 dummy 0 0 0 0 0 dummy 0 0 0 0 0 dummy 0 0 0 0 0 numiptent 14 14 200 200 0 TOP: (In January the load avg was really high 3-10, I was able to bring it down where it is currently is by giving APC more memory play around with) top - 16:46:07 up 2:13, 1 user, load average: 0.34, 0.20, 0.20 Tasks: 40 total, 2 running, 37 sleeping, 0 stopped, 1 zombie Cpu(s): 0.3% us, 0.1% sy, 0.0% ni, 99.7% id, 0.0% wa, 0.0% hi, 0.0% si Mem: 916144k total, 156668k used, 759476k free, 0k buffers Swap: 0k total, 0k used, 0k free, 0k cached MySQLTuner: (after optimizing every table and repairing any table with overage I got the fragmented count down to 86) [--] Data in MyISAM tables: 285M (Tables: 1105) [!!] Total fragmented tables: 86 [--] Up for: 2h 44m 38s (409K q [41.421 qps], 6K conn, TX: 1B, RX: 174M) [--] Reads / Writes: 79% / 21% [--] Total buffers: 58.0M global + 2.7M per thread (100 max threads) [!!] Query cache prunes per day: 675307 [!!] Temporary tables created on disk: 35% (7K on disk / 20K total)

    Read the article

  • Munin not creating HTML files in Ubuntu Server 14.04

    - by lepe
    I have used munin in several servers and this is the first time is taking me so much time to set it up. When I telnet munin directly, I can list the services, there is no error at the logs and munin its being updated every 5 minutes. However no html files are created. I'm using the default location (/var/cache/munin/www) and I can confirm the permissions of that directory are set to munin.munin (IP and domain has been changed) munin.conf: dbdir /var/lib/munin htmldir /var/cache/munin/www logdir /var/log/munin rundir /var/run/munin [example.com;] address 100.100.50.200 munin-node.conf: log_level 4 log_file /var/log/munin/munin-node.log pid_file /var/run/munin/munin-node.pid background 1 setsid 1 user root group root host_name example.com allow ^127\.0\.0\.1$ allow ^100\.100\.50\.200$ allow ^::1$ /etc/hosts : 100.100.50.200 example.com 127.0.0.1 localhost $ telnet example.com 4949 Trying 100.100.50.200... Connected to example.com. Escape character is '^]'. # munin node at example.com list apache_accesses apache_processes apache_volume cpu cpuspeed df df_inode entropy fail2ban forks fw_packets if_err_eth0 if_err_eth1 if_eth0 if_eth1 interrupts ipmi_fans ipmi_power ipmi_temp irqstats load memory munin_stats mysql_bin_relay_log mysql_commands mysql_connections mysql_files_tables mysql_innodb_bpool mysql_innodb_bpool_act mysql_innodb_insert_buf mysql_innodb_io mysql_innodb_io_pend mysql_innodb_log mysql_innodb_rows mysql_innodb_semaphores mysql_innodb_tnx mysql_myisam_indexes mysql_network_traffic mysql_qcache mysql_qcache_mem mysql_replication mysql_select_types mysql_slow mysql_sorts mysql_table_locks mysql_tmp_tables ntp_2001:e40:100:208::123 ntp_91.189.94.4 ntp_kernel_err ntp_kernel_pll_freq ntp_kernel_pll_off ntp_offset ntp_states open_files open_inodes postfix_mailqueue postfix_mailvolume proc_pri processes swap threads uptime users vmstat fetch df _dev_sda3.value 2.1762874086869 _sys_fs_cgroup.value 0 _run.value 0.0503536980635825 _run_lock.value 0 _run_shm.value 0 _run_user.value 0 _dev_sda5.value 0.0176986285727571 _dev_sda8.value 1.08464646179852 _dev_sda7.value 0.0346633563514803 _dev_sda9.value 6.81031810822797 _dev_sda6.value 9.0932802215469 . /var/log/munin/munin-node.log Process Backgrounded 2014/08/16-14:13:36 Munin::Node::Server (type Net::Server::Fork) starting! pid(19610) Binding to TCP port 4949 on host 100.100.50.200 with IPv4 2014/08/16-14:23:11 CONNECT TCP Peer: "[100.100.50.200]:55949" Local: "[100.100.50.200]:4949" 2014/08/16-14:36:16 CONNECT TCP Peer: "[100.100.50.200]:56209" Local: "[100.100.50.200]:4949" /var/log/munin/munin-update.log ... 2014/08/16 14:30:01 [INFO]: Starting munin-update 2014/08/16 14:30:01 [INFO]: Munin-update finished (0.00 sec) 2014/08/16 14:35:02 [INFO]: Starting munin-update 2014/08/16 14:35:02 [INFO]: Munin-update finished (0.00 sec) 2014/08/16 14:40:01 [INFO]: Starting munin-update 2014/08/16 14:40:01 [INFO]: Munin-update finished (0.00 sec) $ ls -la /var/cache/munin/www/ drwxr-xr-x 3 munin munin 19 Aug 16 13:55 . drwxr-xr-x 3 root root 16 Aug 16 13:54 .. drwxr-xr-x 2 munin munin 4096 Aug 16 13:55 static Any ideas on why it is not working? EDIT This is how /var/log/munin/ log looks like after some days: -rw-r----- 1 www-data 0 Aug 16 13:54 munin-cgi-graph.log -rw-r----- 1 www-data 0 Aug 16 13:54 munin-cgi-html.log -rw-rw-r-- 1 munin 0 Aug 16 13:55 munin-html.log -rw-r----- 1 munin 0 Aug 19 06:18 munin-limits.log -rw-r----- 1 munin 15K Aug 18 14:10 munin-limits.log.1 -rw-r----- 1 munin 1.8K Aug 18 06:15 munin-limits.log.2.gz -rw-rw-r-- 1 munin 1.3K Aug 17 06:15 munin-limits.log.3.gz -rw-r--r-- 1 root 6.5K Aug 16 13:55 munin-node-configure.log -rw-r--r-- 1 root 0 Aug 17 06:18 munin-node.log -rw-r--r-- 1 root 420 Aug 16 14:52 munin-node.log.1.gz -rw-r----- 1 munin 0 Aug 19 06:18 munin-update.log -rw-r----- 1 munin 11K Aug 18 14:10 munin-update.log.1 -rw-r----- 1 munin 1.6K Aug 18 06:15 munin-update.log.2.gz -rw-rw-r-- 1 munin 1.5K Aug 17 06:15 munin-update.log.3.gz

    Read the article

  • Xen kernel can't see 2 disks of 6 of 1TB, does it have a limitation?

    - by PartySoft
    Linux gentoo-xen 2.6.18-xen-r12 #3 SMP Tue Oct 5 09:28:53 PDT 2010 x86_64 Intel(R) Xeon(R) CPU E5506 @ 2.13GHz GenuineIntel GNU/Linux I have 6 disks of 1 TB and i can't see all of them only 4, can anyone give me an ideea what can i do ? Filesystem Size Used Avail Use% Mounted on rootfs 886G 4.4G 836G 1% / /dev/sda3 886G 4.4G 836G 1% / rc-svcdir 1.0M 44K 980K 5% /lib64/rc/init.d shm 7.9G 0 7.9G 0% /dev/shm /dev/sdb1 917G 200M 871G 1% /home2 /dev/sdc1 917G 200M 871G 1% /home3 /dev/sdd1 917G 200M 871G 1% /home4 The hardware is Dual xeon E5506 processors on a supermicro X8DTL mobo 4.346585] ata3.00: ATA-8, max UDMA/133, 1953525168 sectors: LBA48 NCQ (depth 0/32) [ 4.346588] ata3.00: ata3: dev 0 multi count 16 [ 4.352861] ata3.00: configured for UDMA/133 [ 4.352867] scsi3 : ata_piix [ 4.352875] PM: Adding info for No Bus:host3 [ 4.510584] ata4.00: ATA-8, max UDMA/133, 1953525168 sectors: LBA48 NCQ (depth 0/32) [ 4.510587] ata4.00: ata4: dev 0 multi count 16 [ 4.516848] ata4.00: configured for UDMA/133 [ 4.516861] PM: Adding info for No Bus:target2:0:0 [ 4.516905] Vendor: ATA Model: SAMSUNG HD103SJ Rev: 1AJ1 [ 4.516910] Type: Direct-Access ANSI SCSI revision: 05 [ 4.516920] PM: Adding info for scsi:2:0:0:0 [ 4.517452] SCSI device sde: 1953525168 512-byte hdwr sectors (1000205 MB) [ 4.517460] sde: Write Protect is off [ 4.517461] sde: Mode Sense: 00 3a 00 00 [ 4.517478] SCSI device sde: drive cache: write back [ 4.517514] SCSI device sde: 1953525168 512-byte hdwr sectors (1000205 MB) [ 4.517521] sde: Write Protect is off [ 4.517522] sde: Mode Sense: 00 3a 00 00 [ 4.517532] SCSI device sde: drive cache: write back [ 4.517534] sde: sde1 [ 4.524551] sd 2:0:0:0: Attached scsi disk sde [ 4.524855] sd 2:0:0:0: Attached scsi generic sg4 type 0 [ 4.524874] PM: Adding info for No Bus:target3:0:0 [ 4.524928] Vendor: ATA Model: SAMSUNG HD103SJ Rev: 1AJ1 [ 4.524933] Type: Direct-Access ANSI SCSI revision: 05 [ 4.524946] PM: Adding info for scsi:3:0:0:0 [ 4.525216] SCSI device sdf: 1953525168 512-byte hdwr sectors (1000205 MB) [ 4.525227] sdf: Write Protect is off [ 4.525228] sdf: Mode Sense: 00 3a 00 00 [ 4.525242] SCSI device sdf: drive cache: write back [ 4.525280] SCSI device sdf: 1953525168 512-byte hdwr sectors (1000205 MB) [ 4.525286] sdf: Write Protect is off [ 4.525289] sdf: Mode Sense: 00 3a 00 00 [ 4.525301] SCSI device sdf: drive cache: write back [ 4.525302] sdf: sdf1 [ 4.532691] sd 3:0:0:0: Attached scsi disk sdf [ 4.533010] sd 3:0:0:0: Attached scsi generic sg5 type 0 [ 4.977669] scsi: <fdomain> Detection failed (no card) [ 5.030479] GDT-HA: Storage RAID Controller Driver. Version: 3.05 [ 5.030635] GDT-HA: Found 0 PCI Storage RAID Controllers [ 5.372350] Fusion MPT base driver 3.04.01 [ 5.372358] Copyright (c) 1999-2005 LSI Logic Corporation [ 5.579176] Fusion MPT SPI Host driver 3.04.01 [ 5.881777] ieee1394: Initialized config rom entry `ip1394' [ 6.166745] ieee1394: sbp2: Driver forced to serialize I/O (serialize_io=1) [ 6.166748] ieee1394: sbp2: Try serialize_io=0 for better performance [ 6.428866] md: md driver 0.90.3 MAX_MD_DEVS=256, MD_SB_DISKS=27 [ 6.428872] md: bitmap version 4.39 [ 6.431518] md: raid0 personality registered for level 0 [ 6.495979] md: raid1 personality registered for level 1 [ 6.570270] raid5: automatically using best checksumming function: generic_sse [ 6.575523] generic_sse: 6608.000 MB/sec [ 6.575526] raid5: using function: generic_sse (6608.000 MB/sec) [ 6.596226] raid6: int64x1 1835 MB/s [ 6.613231] raid6: int64x2 1773 MB/s [ 6.630256] raid6: int64x4 1675 MB/s [ 6.647296] raid6: int64x8 1027 MB/s [ 6.664267] raid6: sse2x1 3578 MB/s [ 6.681268] raid6: sse2x2 4207 MB/s [ 6.698280] raid6: sse2x4 4625 MB/s [ 6.698281] raid6: using algorithm sse2x4 (4625 MB/s) [ 6.698285] md: raid6 personality registered for level 6 [ 6.698286] md: raid5 personality registered for level 5 [ 6.698288] md: raid4 personality registered for level 4 [ 6.781090] md: raid10 personality registered for level 10 [ 7.007043] Intel(R) PRO/1000 Network Driver - version 7.1.9-k4 [ 7.007046] Copyright (c) 1999-2006 Intel Corporation. [ 9.229465] kjournald starting. Commit interval 5 seconds [ 9.229476] EXT3-fs: mounted filesystem with ordered data mode.

    Read the article

  • A faulty Caviar Blue hard drive?

    - by Glister
    We have a small "homemade" server running fully updated Debian Wheezy (amd64). One hard drive installed: WDC WD6400AAKS. The motherboard is ASUS M4N68T V2. The usual load: CPU: an average of 20% Each week about 50GB of additional space is occupied. About 47GB of uploaded files and 3GB of MySQL data. I'm afraid that the hard drive may be about to fail. I saw Pre-fail on few places when I ran: root@SERVER:/tmp# smartctl -a /dev/sda smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-4-amd64] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Blue Serial ATA Device Model: WDC WD6400AAKS-XXXXXXX Serial Number: WD-XXXXXXXXXXXXXXXXXXX LU WWN Device Id: 5 0014ee XXXXXXXXXXXXX Firmware Version: 01.03B01 User Capacity: 640,135,028,736 bytes [640 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Oct 28 18:55:27 2013 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x85) Offline data collection activity was aborted by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 247) Self-test routine in progress... 70% of test remaining. Total time to complete Offline data collection: (11580) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 136) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 157 146 021 Pre-fail Always - 5108 4 Start_Stop_Count 0x0032 098 098 000 Old_age Always - 2968 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 051 Old_age Always - 0 9 Power_On_Hours 0x0032 079 079 000 Old_age Always - 15445 10 Spin_Retry_Count 0x0032 100 100 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 051 Old_age Always - 0 12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 2950 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 426 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 2968 194 Temperature_Celsius 0x0022 111 095 000 Old_age Always - 36 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 160 000 Old_age Always - 21716 200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15444 - Error SMART Read Selective Self-Test Log failed: scsi error aborted command Smartctl: SMART Selective Self Test Log Read Failed root@SERVER:/tmp# In one tutorial I read that the pre-fail is a an indication of coming failure, in another tutorial I read that it is not true. Can you guys help me decode the output of smartctl? It would be also nice to share suggestions what should I do if I want to ensure data integrity (about 50GB of new data each week, up to 2TB for the whole period I'm interested in). Maybe I will go with 2x2TB Caviar Black in RAID4?

    Read the article

  • Kernel panic when bringing up DRBD resource

    - by sc.
    I'm trying to set up two machines synchonizing with DRBD. The storage is setup as follows: PV - LVM - DRBD - CLVM - GFS2. DRBD is set up in dual primary mode. The first server is set up and running fine in primary mode. The drives on the first server have data on them. I've set up the second server and I'm trying to bring up the DRBD resources. I created all the base LVM's to match the first server. After initializing the resources with `` drbdadm create-md storage I'm bringing up the resources by issuing drbdadm up storage After issuing that command, I get a kernel panic and the server reboots in 30 seconds. Here's a screen capture. My configuration is as follows: OS: CentOS 6 uname -a Linux host.structuralcomponents.net 2.6.32-279.5.2.el6.x86_64 #1 SMP Fri Aug 24 01:07:11 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux rpm -qa | grep drbd kmod-drbd84-8.4.1-2.el6.elrepo.x86_64 drbd84-utils-8.4.1-2.el6.elrepo.x86_64 cat /etc/drbd.d/global_common.conf global { usage-count yes; # minor-count dialog-refresh disable-ip-verification } common { handlers { pri-on-incon-degr "/usr/lib/drbd/notify-pri-on-incon-degr.sh; /usr/lib/drbd/notify-emergency-reboot.sh; echo b /proc/sysrq-trigger ; reboot -f"; pri-lost-after-sb "/usr/lib/drbd/notify-pri-lost-after-sb.sh; /usr/lib/drbd/notify-emergency-reboot.sh; echo b /proc/sysrq-trigger ; reboot -f"; local-io-error "/usr/lib/drbd/notify-io-error.sh; /usr/lib/drbd/notify-emergency-shutdown.sh; echo o /proc/sysrq-trigger ; halt -f"; # fence-peer "/usr/lib/drbd/crm-fence-peer.sh"; # split-brain "/usr/lib/drbd/notify-split-brain.sh root"; # out-of-sync "/usr/lib/drbd/notify-out-of-sync.sh root"; # before-resync-target "/usr/lib/drbd/snapshot-resync-target-lvm.sh -p 15 -- -c 16k"; # after-resync-target /usr/lib/drbd/unsnapshot-resync-target-lvm.sh; } startup { # wfc-timeout degr-wfc-timeout outdated-wfc-timeout wait-after-sb become-primary-on both; wfc-timeout 30; degr-wfc-timeout 10; outdated-wfc-timeout 10; } options { # cpu-mask on-no-data-accessible } disk { # size max-bio-bvecs on-io-error fencing disk-barrier disk-flushes # disk-drain md-flushes resync-rate resync-after al-extents # c-plan-ahead c-delay-target c-fill-target c-max-rate # c-min-rate disk-timeout } net { # protocol timeout max-epoch-size max-buffers unplug-watermark # connect-int ping-int sndbuf-size rcvbuf-size ko-count # allow-two-primaries cram-hmac-alg shared-secret after-sb-0pri # after-sb-1pri after-sb-2pri always-asbp rr-conflict # ping-timeout data-integrity-alg tcp-cork on-congestion # congestion-fill congestion-extents csums-alg verify-alg # use-rle protocol C; allow-two-primaries yes; after-sb-0pri discard-zero-changes; after-sb-1pri discard-secondary; after-sb-2pri disconnect; } } cat /etc/drbd.d/storage.res resource storage { device /dev/drbd0; meta-disk internal; on host.structuralcomponents.net { address 10.10.1.120:7788; disk /dev/vg_storage/lv_storage; } on host2.structuralcomponents.net { address 10.10.1.121:7788; disk /dev/vg_storage/lv_storage; } /var/log/messages is not logging anything about the crash. I've been trying to find a cause of this but I've come up with nothing. Can anyone help me out? Thanks.

    Read the article

  • mod_mono 'Service Temporarily Unavailable' issue

    - by Charlie Somerville
    I've deployed an ASP.NET web application on a Linux (Debian) server running Apache 2.2 and mod_mono 1.9 It's working well, however Mono occasionally segfaults and uses the entire CPU which causes the website to stop working and display 'Service Temporarily Unavailable' Killing mono fixes it, but obviously this isn't a good solution. I tailed the system log after this happened and I saw the following error messages from the kernel: Apr 20 01:49:37 charliesomerville kernel: [1596436.204158] mono[17909]: segfault at b645f671 ip b645f671 sp b4ffb604 error 4<6>mono[19047]: segfault at b645f66e ip b645f66e sp b4bf7604 error 4<6>mono[18017]: segfault at b645f66e ip b645f66e sp b52fe604 error 4<6>mono[19668]: segfault at b645f5e6 ip b645f5e6 sp b48f4604 error 4<6>mono[22565]: segfault at b645f674 ip b645f674 sp b45f1604 error 4<6>mono[17700]: segfault at b645f661 ip b645f661 sp b51fd604 error 4<6>mono[19596]: segfault at b645f5e6 ip b645f5e6 sp b49f5604 error 4 Apr 20 01:49:37 charliesomerville kernel: [1596436.208172] mono[23219]: segfault at b645f66e ip b645f66e sp b44f0604 error 4 At the end of Apache's error.log are the following errors: [Tue Apr 20 03:10:23 2010] [error] (70014)End of file found: read_data failed [Tue Apr 20 03:10:23 2010] [error] Command stream corrupted, last command was 1 [Tue Apr 20 03:10:23 2010] [error] Command stream corrupted, last command was 1 [Tue Apr 20 03:10:23 2010] [error] Command stream corrupted, last command was 1 System.ArgumentNullException: null key Parameter name: key at System.Collections.Hashtable.get_Item (System.Object key) [0x00000] at System.Runtime.Serialization.SerializationCallbacks.GetSerializationCallbacks (System.Type t) [0x00000] at System.Runtime.Serialization.ObjectManager.RaiseOnDeserializingEvent (System.Object obj) [0x00000] at System.Runtime.Serialization.Formatters.Binary.ObjectReader.ReadObjectContent (System.IO.BinaryReader reader, System.Runtime.Serialization.Formatters.Binary.TypeMetadata metadata, Int64 objectId, System.Object& objectInstance, System.Runtime.Serialization.SerializationInfo& info) [0x00000] at System.Runtime.Serialization.Formatters.Binary.ObjectReader.ReadObjectInstance (System.IO.BinaryReader reader, Boolean isRuntimeObject, Boolean hasTypeInfo, System.Int64& objectId, System.Object& value, System.Runtime.Serialization.SerializationInfo& info) [0x00000] at System.Runtime.Serialization.Formatters.Binary.ObjectReader.ReadObject (BinaryElement element, System.IO.BinaryReader reader, System.Int64& objectId, System.Object& value, System.Runtime.Serialization.SerializationInfo& info) [0x00000] at System.Runtime.Serialization.Formatters.Binary.ObjectReader.ReadNextObject (System.IO.BinaryReader reader) [0x00000] at System.Runtime.Serialization.Formatters.Binary.ObjectReader.ReadObjectGraph (System.IO.BinaryReader reader, Boolean readHeaders, System.Object& result, System.Runtime.Remoting.Messaging.Header[]& headers) [0x00000] at System.Runtime.Serialization.Formatters.Binary.BinaryFormatter.NoCheckDeserialize (System.IO.Stream serializationStream, System.Runtime.Remoting.Messaging.HeaderHandler handler) [0x00000] at System.Runtime.Serialization.Formatters.Binary.BinaryFormatter.Deserialize (System.IO.Stream serializationStream) [0x00000] at System.Runtime.Remoting.Channels.CADSerializer.DeserializeObject (System.IO.MemoryStream mem) [0x00000] at System.Runtime.Remoting.RemotingServices.GetDomainProxy (System.AppDomain domain) [0x00000] at System.AppDomain.CreateDomain (System.String friendlyName, System.Security.Policy.Evidence securityInfo, System.AppDomainSetup info) [0x00000] at System.Web.Hosting.ApplicationHost.CreateApplicationHost (System.Type hostType, System.String virtualDir, System.String physicalDir) [0x00000] at Mono.WebServer.VPathToHost.CreateHost (Mono.WebServer.ApplicationServer server, Mono.WebServer.WebSource webSource) [0x00000] at Mono.WebServer.ApplicationServer.GetApplicationForPath (System.String vhost, Int32 port, System.String path, Boolean defaultToRoot) [0x00000] at (wrapper remoting-invoke-with-check) Mono.WebServer.ApplicationServer:GetApplicationForPath (string,int,string,bool) at Mono.WebServer.ModMonoWorker.GetOrCreateApplication (System.String vhost, Int32 port, System.String filepath, System.String virt) [0x00000] at Mono.WebServer.ModMonoWorker.InnerRun (System.Object state) [0x00000] at Mono.WebServer.ModMonoWorker.Run (System.Object state) [0x00000] [Tue Apr 20 03:10:26 2010] [error] (70014)End of file found: read_data failed [Tue Apr 20 03:10:26 2010] [error] Command stream corrupted, last command was -1 Along with the above errors, Apache's error.log is packed with hundreds (if not thousands) of the following error: Maximum number (20) of concurrent mod_mono requests to /tmp/mod_mono_dashboard_default_2.lock reached. Droping request. At the moment, I'm thinking there might be something wrong with configuration here (it's basically running on out-of-the-box config)

    Read the article

  • Why the server is not responding?

    - by par
    Hello! Our server occasionally refuses to serve a simple HTML page. This is happening during a relatively high number of requests. However, the processor is not heavy loaded and there are a lot of free memory. The error seems to occure 1 out of 50 requests in average, depending on the server load. I need to find the source of the problem and take the appropriate actions to eliminate it. I have a suspicion that the problem source is a huge number of incoming network packets. There are 5000 packets per second on average. Traffic - 2 MBits/sec Can this be the cause of the error? There is an interesting thing, in case the server fails to respond, the request string is not logged to access.log by Apache. The error is repeatable from several client computers. DNS is not involved, since I have accessed the server by the IP. I have profiled the problem case with tcpdump utility. These are the good and bad sessions traced by tcpdump. The request is the same in both experiments. Good - server returns response. Bad - no response, time-out error. ---- Bad ---- 12:23:36.366292 IP 123.45.67.890.61749 > myserver.superbservers.com.www: S 2125316338:2125316338(0) win 8192 <mss 1460,nop,wscale 2,nop,nop,sackOK> 12:23:39.362394 IP 123.45.67.890.61749 > myserver.superbservers.com.www: S 2125316338:2125316338(0) win 8192 <mss 1460,nop,wscale 2,nop,nop,sackOK> 12:23:45.365567 IP 123.45.67.890.61749 > myserver.superbservers.com.www: S 2125316338:2125316338(0) win 8192 <mss 1460,nop,nop,sackOK> -------- ---- Good ---- 12:27:07.632229 IP 123.45.67.890.63914 > myserver.superbservers.com.www: S 3581365570:3581365570(0) win 8192 <mss 1460,nop,wscale 2,nop,nop,sackOK> 12:27:10.620946 IP 123.45.67.890.63914 > myserver.superbservers.com.www: S 3581365570:3581365570(0) win 8192 <mss 1460,nop,wscale 2,nop,nop,sackOK> 12:27:10.620969 IP myserver.superbservers.com.www > 123.45.67.890.63914: S 2654770980:2654770980(0) ack 3581365571 win 5840 <mss 1460,nop,nop,sackOK,nop,wscale 6> 12:27:10.838747 IP 123.45.67.890.63914 > myserver.superbservers.com.www: . ack 1 win 4380 12:27:10.957143 IP 123.45.67.890.63914 > myserver.superbservers.com.www: P 1:213(212) ack 1 win 4380 12:27:10.957152 IP myserver.superbservers.com.www > 123.45.67.890.63914: . ack 213 win 108 12:27:10.965543 IP myserver.superbservers.com.www > 123.45.67.890.63914: P 1:630(629) ack 213 win 108 12:27:10.965621 IP myserver.superbservers.com.www > 123.45.67.890.63914: F 630:630(0) ack 213 win 108 12:27:11.183540 IP 123.45.67.890.63914 > myserver.superbservers.com.www: . ack 631 win 4222 12:27:11.185657 IP 123.45.67.890.63914 > myserver.superbservers.com.www: F 213:213(0) ack 631 win 4222 12:27:11.185663 IP myserver.superbservers.com.www > 123.45.67.890.63914: . ack 214 win 108 -------- Hoster: SuperbHosting OS: Ubuntu Server parameters: E6300 CONROE 1.86GHZ 2 X 1MB CACHE 1066 1GB DDR2 667MHZ This is a link to apache configuration file we use http://repkin5.snow.prohosting.com/apache.txt This is server-status report taken right after time-out error. http://repkin5.snow.prohosting.com/server-status.htm There are only 10 Child Servers running out of 120, so enough space for new requests. VMSTAT procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 0 0 8900 725900 8468 65684 0 0 5 18 11 33 4 3 92 1

    Read the article

  • MS Securily Essentials efficiency / usage, suspicious processes

    - by biggvsdiccvs
    I recently noticed that my (originally pretty fast) Windows 7 Pro laptop started getting slow and using a lot of CPU power for no apparent reason. A full scan by Microsoft Security Essentials revealed nothing. After some investigation, I found multiple instances of a strange process called urpev.exe and a couple of similar exe files sitting in subdirectories of Users//AppData/Roaming (this particular one was in a folder called Xyceowme). Description: "Mescrosift Visaal Studie 2010". Company name: "Mesrosift Corporatien". Is it a virus or something? :) Now, all of these exe files were scheduled to be started from the Task Scheduler by tasks with names like "Security Center Update - 1291373911" and similar. My user name was listed as the author of the tasks. I disabled the tasks, restarted the computer in safe mode and moved all of the exe files to quarantine for further investigation. All of this was done last night. I just scanned the files with Security Essentials again (not updated since yesterday) in the quarantine location and this time it found PWS:Win32/Zbot.gen!plock in urpev.exe (but not in the other exe files, which are most likely viruses, too). Category: Password Stealer Description: This program is dangerous and captures user passwords. Another strange process is browser.exe (not chrome.exe) by Google Inc., described as Google Chrome. I uninstalled Chrome but it's still there. It runs out of Users\\AppData\LocalLow\UIVoice\ToolMedium\browser.exe and if I move it in safe mode, it just reappears there, and multiple instances run. Needless to say, it I kill it, it just runs again. Couldn't see anything in Task Scheduler, but found a couple of references to it in the Registry Editor: HKEY_CURRENT_USER/Software/Microsoft/Internet Explorer/LowRegistry/Audio/PolicyConfig/PropertyStore/ HKEY_USERS/S-1-5-21-1685709306-872053864-2599010960-1002/Software/Microsoft/Internet Explorer/LowRegistry/Audio/PolicyConfig/PropertyStore/ Maybe it's a legit process, but seems kind of strange. For the time being, I suspended the process and killed all of the child processes when I booted up the laptop. I used Security Essentials to scan the system periodically, but obviously it's not effective at least against one virus. I had the "real-time protection" turned off. Would it help if it were turned on and how much of a nuisance would it be? I wonder if there is a better alternative to Security Essentials. Over the years I've used multiple antivirus products at home and especially at work and was not very happy with any of them. Apparently, asking for software recommendations or comparisons is taboo here, but I will mention that I installed Malware Bytes and it was able to find an quarantine a bunch of suspicious files, and at least some of which were truly infected, but when it scans the bogus security center update executables from Mesrosift Corporatien, it finds nothing wrong. Also, any thoughts on the browser.exe mystery? Neither MS Security Essentials nor Malware Bytes found anything wrong with that file. However, after I ran a Malware Bytes scan and quarantined everything it found suspicious and rebooted the laptop, the process did not run.

    Read the article

  • register_globals error in php

    - by user145862
    I was stuck up with the error directive 'register_globals' is no longer available in PHP in unknown on line 0 when tried to check the php version using "php -v" after enabling register_globals in php.ini file. I am not getting any php version info by doing so. Instead it throws the above mentioned error.After turning off this option, php info works quite well. It is very essential for me to have register_globals to be turned on.How can I have this corrected. my php.ini is as follows: ; Default Value: None ; Development Value: "GP" ; Production Value: "GP" ; http://php.net/request-order request_order = "GP" ; Whether or not to register the EGPCS variables as global variables. You may ; want to turn this off if you don't want to clutter your scripts' global scope ; with user data. ; You should do your best to write your scripts so that they do not require ; register_globals to be on; Using form variables as globals can easily lead ; to possible security problems, if the code is not very well thought of. ; register_globals = On ; Determines whether the deprecated long $HTTP_*_VARS type predefined variables ; are registered by PHP or not. As they are deprecated, we obviously don't ; recommend you use them. They are on by default for compatibility reasons but ; they are not recommended on production servers. ; Default Value: On ; Development Value: Off ; Production Value: Off ; register_long_arrays = Off ; This directive determines whether PHP registers $argv & $argc each time it ; runs. $argv contains an array of all the arguments passed to PHP when a script ; is invoked. $argc contains an integer representing the number of arguments ; that were passed when the script was invoked. These arrays are extremely ; useful when running scripts from the command line. When this directive is ; enabled, registering these variables consumes CPU cycles and memory each time ; a script is executed. For performance reasons, this feature should be disabled ; on production servers. ; Note: This directive is hardcoded to On for the CLI SAPI ; Default Value: On ; Development Value: Off ; Production Value: Off ; register_argc_argv = Off ; When enabled, the SERVER and ENV variables are created when they're first ; used (Just In Time) instead of when the script starts. If these variables ; are not used within a script, having this directive on will result in a ; performance gain. The PHP directives register_globals, register_long_arrays, ; and register_argc_argv must be disabled for this directive to have any affect. ; auto_globals_jit = On

    Read the article

  • Linux not buffering block I/O when the device is not "in use" (i.e. mounted)

    - by Radek Hladík
    I am installing new server and I've found an interesting issue. The server is running Fedora 19 (3.11.7-200.fc19.x86_64 kernel) and is supposed to host a few KVM/Qemu virtual servers (mail server, file server, etc..). The HW is Intel(R) Xeon(R) CPU 5160 @ 3.00GHz with 16GB RAM. One of the most important features will be Samba server and we have decided to make it as virtual machine with almost direct access to the disks. So the real HDD is cached on SSD (via bcache) then raided with md and the final device is exported into the virtual machine via virtio. The virtual machine is again Fedora 19 with the same kernel. One important topic to find out is whether the virtualization layer will not introduce high overload into disk I/Os. So far I've been able to get up to 180MB/s in VM and up to 220MB/s on real HW (on the SSD disk). I am still not sure why the overhead is so big but it is more than the network can handle so I do not care so much. The interesting thing is that I've found that the disk reads are not buffered in the VM unless I create and mount FS on the disk or I use the disks somehow. Simply put: Lets do dd to read disk for the first time (the /dev/vdd is an old Raptor disk 70MB/s is its real speed): [root@localhost ~]# dd if=/dev/vdd of=/dev/null bs=256k count=10000 ; cat /proc/meminfo | grep Buffers 2621440000 bytes (2.6 GB) copied, 36.8038 s, 71.2 MB/s Buffers: 14444 kB Rereading the data shows that they are cached somewhere but not in buffers of the VM. Also the speed increased to "only" 500MB/s. The VM has 4GB of RAM (more that the test file) [root@localhost ~]# dd if=/dev/vdd of=/dev/null bs=256k count=10000 ; cat /proc/meminfo | grep Buffers 2621440000 bytes (2.6 GB) copied, 5.16016 s, 508 MB/s Buffers: 14444 kB [root@localhost ~]# dd if=/dev/vdd of=/dev/null bs=256k count=10000 ; cat /proc/meminfo | grep Buffers 2621440000 bytes (2.6 GB) copied, 5.05727 s, 518 MB/s Buffers: 14444 kB Now lets mount the FS on /dev/vdd and try the dd again: [root@localhost ~]# mount /dev/vdd /mnt/tmp [root@localhost ~]# dd if=/dev/vdd of=/dev/null bs=256k count=10000 ; cat /proc/meminfo | grep Buffers 2621440000 bytes (2.6 GB) copied, 4.68578 s, 559 MB/s Buffers: 2574592 kB [root@localhost ~]# dd if=/dev/vdd of=/dev/null bs=256k count=10000 ; cat /proc/meminfo | grep Buffers 2621440000 bytes (2.6 GB) copied, 1.50504 s, 1.7 GB/s Buffers: 2574592 kB While the first read was the same, all 2.6GB got buffered and the next read was at 1.7GB/s. And when I unmount the device: [root@localhost ~]# umount /mnt/tmp [root@localhost ~]# cat /proc/meminfo | grep Buffers Buffers: 14452 kB [root@localhost ~]# dd if=/dev/vdd of=/dev/null bs=256k count=10000 ; cat /proc/meminfo | grep Buffers 2621440000 bytes (2.6 GB) copied, 5.10499 s, 514 MB/s Buffers: 14468 kB The bcache was disabled while testing and the results are same on faster (newer) HDDs and on SSD (except for the initial read speed of course). To sum it up. When I read from the device via dd first time, it gets read from the disk. Next time I reread it gets cached in the host but not in the guest (thats actually the same issue, more on that later). When I mount the filesystem but try to read the device directly it gets cached in VM (via buffers). As soon as I stop "using" it, buffers are discarded and the device is not cached anymore in the VM. When I looked into buffers value on the host I realized that the situation is the same. The block I/O gets buffered only when the disk is in use, in this case it means "exported to a VM". On host, after all the measurement done: 3165552 buffers On the host, after the VM shutdown: 119176 buffers I know it is not important as the disks will be mounted all the time but I am curious and I would like to know why it is working like this.

    Read the article

  • Tuning performance of Ubuntu 10.04 on Compaq Evo W4000.

    - by Fantomas
    Hi, I got this computer free and installed Ubuntu 10.04 on it + updates, plus followed the following tutorial all the way: http://www.unixmen.com/linux-tutorials/937-things-to-do-after-installing-ubuntu-1004-lts-lucid-lynx I love the Docky which comes with it, but the computer has been running rather slowly. The System: kernel 2.6.32-22-generic Gnome 2.30.0 (I like Gnome!) Memory: 1GB Processor: Intel (R) Pentium (R) 4 CPU 1700 MHz (needless to say, it is 32 bit). I think I dedicated 128 Mb to video memory while installing, but cannot find this setting now. I did also install an NVidia driver for the 3D card, so I probably want to reclaim that memory back. I want to trim the fat but I also want to keep some of the sex appeal of Ubuntu 10.04. I will gift this computer to a friend, who will use it for Internet, music, videos, word processing, Skype and instant messaging - he is non-technical, so this hardware and Linux should work for him; I just need to speed it up while keeping the good software and having a nice UI. I sort of know my way around Linux, but not that well. Feel free to ask me to run particular commands if you want more info. For starters, here are the services below. Which ones can I kill and how? What else can go? There is no need to run ssh or ftp or http or ntp servers. As I said before, this computer is for non-technical person. There is also absolutely no bluetooth or wireless networking needed - it will feed off a regular ethernet cable. What I do not want to do is reinstall some other distro or recompile a kernel. I want to make it 80% perfect spending 20% of the energy :) Thanks! $ service --status-all [ ? ] acpi-support [ ? ] acpid [ ? ] alsa-mixer-save [ ? ] anacron [ - ] apparmor [ ? ] apport [ ? ] atd [ ? ] avahi-daemon [ ? ] binfmt-support [ - ] bluetooth [ - ] bootlogd [ - ] brltty [ ? ] console-setup [ ? ] cron [ + ] cups [ ? ] dbus [ ? ] dmesg [ ? ] dns-clean [ ? ] failsafe-x [ - ] fancontrol [ ? ] gdm [ - ] grub-common [ ? ] hostname [ ? ] hwclock [ ? ] hwclock-save [ ? ] irqbalance [ - ] kerneloops [ ? ] killprocs [ - ] lm-sensors [ ? ] module-init-tools [ ? ] network-interface [ ? ] network-interface-security [ ? ] network-manager [ ? ] networking [ ? ] ondemand [ ? ] pcmciautils [ ? ] plymouth [ ? ] plymouth-log [ ? ] plymouth-splash [ ? ] plymouth-stop [ ? ] pppd-dns [ ? ] procps [ + ] pulseaudio [ ? ] rc.local [ - ] rsync [ ? ] rsyslog [ - ] saned [ ? ] screen-cleanup [ ? ] sendsigs [ ? ] speech-dispatcher [ ? ] stop-bootlogd [ ? ] stop-bootlogd-single [ ? ] udev [ ? ] udev-finish [ ? ] udevmonitor [ ? ] udevtrigger [ ? ] ufw [ ? ] umountfs [ ? ] umountnfs.sh [ ? ] umountroot [ ? ] unattended-upgrades [ - ] urandom [ + ] winbind [ ? ] wpa-ifupdown [ - ] x11-common

    Read the article

  • Random Slow Response

    - by ARehman
    We have an ASP.NET MVC 1.0 application running on Windows Server 2008 – Standard (32 –bit), Dual Core Xeon (3.0 GHz), 2 G.B R.A.M. Most of the times application renders response in 3-4 seconds, but sometimes users get very late response and delay is up to 40 seconds or more than a minute. It happens in following way: User browsed a page, idle for 5, 10 or 15 minutes, tried to browse same page or some other. Now, there is a chance that he will see late response whereas the app pool is still up and running. This can happen with any arbitrary page. We have tried followings/observations. Moved the application to stand alone web server App Pool idle shutdown time is 60 minutes. There are no abrupt shut downs/restarts. CPU or memory doesn’t spike. No delays in SQL queries. Modified App Pool setting to run in classic-mode. It didn’t help. Plugged-in custom module to log all those requests which took more than 5 seconds to complete. It didn’t pick any request of interest. Enabled ‘Failed Request Tracing’ to log all those requests which take 20 or more seconds to complete. It didn’t log anything. Event Viewer, HTTPER log, W3SVC logs or WAS logs don’t indicate anything. HTTPERR only has ‘_ _ Timer_ConnectionIdle _ _’ entries. There is not much traffic to server. This can happen also if only two users are active. Next we captured TCP/IP terrific on both a user and server end with Wireshark and below are details in brief of this slowness: Browser sends a request for ~/User/Home/ (GET Request) by setting up a receiving end point using port 'wlbs(port-2504)'. I'm not sure if this could be a problem in some way that browser didn't hand-shake with the server first and assumed that last connection is still open, whereas, I browsed the same page 4 minutes ago and didn't perform any activity with site after that. If I see the HTTPERR log, it indicates that it has ‘_ _ Timer_ConnectionIdle _ _ _’ entry for my last activity with server. Browser (I was using Chrome) waits for any response from the server, doesn’t find any then starts retransmitting the same request using same end point after incrementing wait intervals, e.g. after 8, 18, 29, 40, 62, and 92 seconds. All these GET requests were received by server as well. But, server didn’t send any packet to client. Browser didn't see any response on the end point it set up in point 1, it opened a new end point 'optiwave-lm (port-2524)', did a hand shake with the server and transmitted the same request again. Server received, processed it, and returned successful response. What happened to earlier 6-7 requests? Whether they were passed on to HTTP.SYS or not? Why Failed Request Tracing not logged anything, we didn't find any clue yet. Server served the same page successfully just 4 minutes ago. Looking forward for more suggestions/solutions. -- Thanks

    Read the article

  • Yet again: "This device can perform faster" (Samsung Galaxy Tab 2)

    - by Mike C
    I've been doing a lot of research with no reasonable solution. Please excuse the length of my post. When I plug my Galaxy Tab 2 (7" / Wi-Fi only / Android ICS) into my Windows 7 64-bit machine, I (almost always) get this warning popup that "This device can perform faster." And in fact, transfers onto the Tab in this mode are slow. The two times I've been able to get a high-speed connection, the transfer has occurred at the expected speed. I just don't know what to do to get that high-speed transfer. (The first time I did, it was the first time I connected the Tab; the second time I did, I was fiddling around and unplugging/plugging in again.) That popup is telling me that the device is USB2, but that it thinks I've connected to a USB1 port. In fact, every USB port (there are ten) on this system is USB2. It's an ASUS M3A78-EMH mobo from late 2008. I'm not sure what the chipset is; the CPU is an AMD Athlon 4850e, but I've seen this message reported for non-AMD systems. (Every mobo reference I've seen in reports on this has been for Asus, but of course most reporters aren't reporting that info at all.) The Windows 7 installation is just a couple weeks old (I had a disk crash) but I saw the same warning on the WinXP/64 that was installed previously. In Device Manager, there are two "Standard Enhanced PCI to USB Host Controller" nodes which are the actual high-speed controllers. There are also five "Standard OpenHCD USB Host Controller" nodes, which I have determined are virtual USB1 controllers embedded in the "Enhanced" controllers. (In Device Manager, I'm using View|Devices by Connection.) My high-speed thumb drives, external disks, and iPod all show up as subnodes of the "Enhanced" controllers; the keyboard, mouse, and USB speakers under the "OpenHCD" ones -- and this is true no matter which ports these devices are plugged into. The Tab shows up under an OpenHCD node, unsurprisingly. It appears as a threesome: a top-level "Mobile USB Composite device" with two subs: "Galaxy Tab 2" and "Mobile USB Modem." (I have no idea what the modem device implies or how I might use it, but I don't care about it either: I just want the Tab to reliably connect at high speed.) On the Tab, the USB support has a switch between PTP and MTP, the latter being the default, and the preferred mode for me (as I'm usually hooking it up for music synch). I have tried, however, connecting it as PTP, and it still connects as USB 1. (As PTP, only the "Galaxy Tab 2" device appears -- no Composite, no Modem.) If it's plugged in as MTP and I change the setting to PTP, Windows unloads and reloads the device, and voila: The Tab appears under an "Enhanced" node, but eventually re-loads again to show a exclamation icon on the device; Properties then shows "This device cannot start." Same response if I plug it in as PTP and then change to MTP; in this case, only the Tab itself shows the exclamation, not the other two devices. One thing I have not tried, and really would prefer to avoid, is installing the "beta" chipset driver available on the Asus website, which is dated 2009. Windows tells me it has the most up-to-date drivers for the Tab, and for the chipset, and I'm inclined to believe that. I suspect the problem is with the Samsung drivers, or possibly the hardware. One suggestion I saw elsewhere which might, possibly, pertain is to ensure the USB cable is properly shielded; however, the Tab has one of those misbegotten 30-pin, not-quite-an-iPod connectors; I don't know if I could find a 3rd party one. It seems unlikely that this cable is improperly shielded, tho. (Is there a way to test that?) So, my question is: does anyone know how to get this working as one might reasonably expect it to?

    Read the article

  • Fix overscan in Linux with Intel graphics Vizio HDTV

    - by Padenton
    I am connecting my server to my HDTV so that I can conveniently display it there. My VIZIO HDTV cuts off all 4 edges. I already realize it is not optimal to be running a GUI on a server; this server will not have much external traffic so I prefer it for convenience. I have already spent countless hours searching for a fix, but all I could find required an ATI or NVIDIA graphics card, or didn’t work. In Windows, the Intel driver has a setting for underscan, though it seems only to be available by a glitch. Here’s my specs: Ubuntu Linux (Quantal 12.10) (Likely to switch to Arch) This is a home server computer, with KDE for managing(for now, at least) Graphics: Intel HD Graphics 4000 from Ivy Bridge Motherboard: ASRock Z77 Extreme4 CPU: Intel Core i5-3450 My monitors: Dell LCD monitor Vizio VX37L_HDTV10A 37" on HDMI input I have tried all of the following from both HDMI?HDMI and DVI?HDMI cables connected to the ports on my motherboard: Setting properties in xrandr Making sure drivers are all up to date Trying several different modes The TV was “cheap”; max resolution 1080i. I am able to get a 1920x1080 modeline, in both GNU/Linux and Windows, without difficulty. There is no setting in the menu to fix the overscan (I have tried all of them, I realize it’s not always called overscan). I have been in the service menu for the TV, which still does not contain an option to fix it. No aspect ratio settings, etc. The TV has a VGA connector but I am unsure if it would fix it, as I don’t have a VGA cable long enough, and am not sure it would get me the 1920x1080 resolution which I want. Using another resolution does not fix the problem. I tried custom modelines with the dimensions of my screen’s viewable area, but it wouldn’t let me use them. Ubuntu apparently doesn’t automatically generate an xorg.conf file for use. I read somewhere that modifying it may help solve it. I tried X -configure several times(with reboots, etc.) but it consistently gave the following error messages: In log file: … (WW) Falling back to old probe method for vesa Number of created screens does not match number of detected devices. Configuration failed. In output: … (++) Using config file: "/root/xorg.conf.new" (==) Using system config directory "/usr/share/X11/xorg.conf.d" Number of created screens does not match number of detected devices. Configuration failed. Server terminated with error (2). Closing log file. Tried using 'overscan' prop in xrandr: root@xxx:/home/xxx# xrandr --output HDMI1 --set overscan off X Error of failed request: BadName (named color or font does not exist) Major opcode of failed request: 140 (RANDR) Minor opcode of failed request: 11 (RRQueryOutputProperty) Serial number of failed request: 42 Current serial number in output stream: 42 'overscan on', 'underscan off', 'underscan on' were all also tried. Originally tried with Ubuntu 12.04, but failed and so updated to 12.10 when it was released. All software is up to date. I am not opposed to reinstalling my OS, likely will anyways (my preference being Arch).

    Read the article

< Previous Page | 266 267 268 269 270 271 272 273 274 275 276 277  | Next Page >