Search Results

Search found 9235 results on 370 pages for 'ipad apple review'.

Page 287/370 | < Previous Page | 283 284 285 286 287 288 289 290 291 292 293 294  | Next Page >

  • Gerrit ssh key setup on windows server

    - by hotpotato
    I am attempting to configure google's 'Gerrit' code review web app on a Windows server 2008 virtual machine on our internal network. We are using Apache Tomcat (6.0.36) to host the web app and have deployed the gerrit.war to tomcats webapp folder, setup the context.xml, web.xml etc for the web app correctly i believe. However when i startup Tomcat using the $CATALINA_HOME/bin/startup.bat i get the following message in the tomcat logs: *Dec 07, 2012 1:03:54 PM org.apache.catalina.core.StandardContext listenerStart SEVERE: Exception sending context initialized event to listener instance of class com.google.gerrit.httpd.WebAppInitializer com.google.inject.CreationException: Guice creation errors:* 1) No SSH keys under C:\Gerrit\config\etc while locating com.google.gerrit.sshd.HostKeyProvider at com.google.gerrit.sshd.SshModule.configure(SshModule.java:90) I have created a is_rsa.pub SSH key and placed it in the specified directory to no avail. I have been googling this for about a week now and can't seem to find any information about the file or format it is expecting... documentation on setting gerrit up on windows seems hard to come by! Can anyone provide useful information about how to correctly configure a host SSH key in this context?

    Read the article

  • How to fix massive lag on ZyXEL HomePlug AV powerline adapters?

    - by Tim Abell
    I have 3 ZyXEL Homeplug AV powerline adapters as per the one in the review below. I have two plugged in currently, one into my Be / Thompson wireless router, and one into my desktop pc (box1). every now and then the link indicator on the adapters (the mains link, not the ethernet link) goes nutty, and performance falls off a cliff (see below). http://www.gadgetspeak.com/gadget/article.rhtm/753/479266/ZyXEL_PowerLine_HomePlug_AV_PLA401.html 64 bytes from box1 (192.168.1.101): icmp_seq=1064 ttl=64 time=996 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1065 ttl=64 time=549 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1066 ttl=64 time=6.15 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1067 ttl=64 time=1400 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1068 ttl=64 time=812 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1069 ttl=64 time=11.1 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1070 ttl=64 time=1185 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1071 ttl=64 time=501 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1072 ttl=64 time=1975 ms 64 bytes from box1 (192.168.1.101): icmp_seq=1073 ttl=64 time=970 ms ^C --- box1 ping statistics --- 1074 packets transmitted, 394 received, +487 errors, 63% packet loss, time 1082497ms rtt min/avg/max/mdev = 5.945/598.452/3526.454/639.768 ms, pipe 4 Any idea how to diagnose/fix? I'm on linux so installing the windoze software that came with them is not something I'm terribly keen to do.

    Read the article

  • Monitoring outgoing messages using EXIM

    - by dashmug
    I work as an IT guy in a law firm. I am recently asked to make a system wherein all the outgoing emails coming from our server to our clients will be put on hold first and wait for approval before it gets sent to the client. Our mail server uses Exim (that's what it says in cPanel). I am planning to create filters where the outgoing emails will be forwarded to an editor account. Then, the editor will review and edit the contents of the email. When the editor already approves the email, it will then get sent to the client by the editor but still using the original sender in the "From:" and "Reply-To:" field. I found some pointers from this site = http://www.devco.net/archives/2006/03/24/saving_copies_of_all_email_using_exim.php. Once the filters are in place, I want to make a simple PHP interface for the editor to check the forwarded emails and edit them if necessary. The editor can then click on an "Approve" button that will finally deliver the message using the original sender. I'm also thinking that maybe a PHP-less system will be enough. The editor can receive the emails from his own email client edit them and simply send the email as if he is the original sender. Is my plan feasible? Will there be issues that I have overlooked? Does it have the danger of being treated as spam by the other mailservers since I'll be messing up the headers?

    Read the article

  • Macbook Pro - 15" with i7 processor - Any problems with heat?

    - by webworm
    You may have already heard about the review done by the folks at PC Authority in Australia, where they had an i7 MacBook Pro that got up to 100 degrees Celsius during benchmarking. Here is the URL in case you have not read it. http://www.pcauthority.com.au/News/172791,macbook-pro-helps-core-i7-hit-100-degrees.aspx In any case, I was considering purchasing a 15" Macbook Pro with the i7 processor and the NVIDIA GeForce GT330M with 512 video memory. Having read how hot the computer got I started to become hesitant about purchasing. My main concern is long term damage to the computer due to excessive heat. I plan to use the MacBook Pro as a development machine where I will be running Windows 7 within VMWare Fusion or Virtual Box. Within the VM I will be running IIS, SQL Server, Visual Studio and SharePoint Server. Hence why I would like to have the power of the i7 processor. That is why I wanted to check with actually owners of the MacBooks with the i7 processor and see what their experiences have been. Have you noticed excessive heat? How does your Macbook handle process intensive apps over long periods of time? Thank you!

    Read the article

  • All websites migrated from server running IIS6 to IIS7

    - by Leah
    Hi, I hope someone will be able to help me with this. We have recently migrated all of our clients' sites to a new server running IIS7 - all the sites were originally running on a server running IIS6. Ever since the migration, lots of our clients are reporting error messages. There seems to be quite a number of issues related to sending emails and also, we have had the following error message reported by several different clients: Server Error in '/' Application. -------------------------------------------------------------------------------- Validation of viewstate MAC failed. If this application is hosted by a Web Farm or cluster, ensure that <machineKey> configuration specifies the same validationKey and validation algorithm. AutoGenerate cannot be used in a cluster. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Web.HttpException: Validation of viewstate MAC failed. If this application is hosted by a Web Farm or cluster, ensure that <machineKey> configuration specifies the same validationKey and validation algorithm. AutoGenerate cannot be used in a cluster. I have read elsewhere that this error can appear if a button is clicked before the whole page has finished loading. But as this error has now appeared on multiple sites and only since the server migration, it seems to me that it must be something else. I was wondering if someone could tell me if there is something specific which needs to be changed for .NET sites when sites are moved from a server running IIS6 to a server running IIS7? I don't deal with the actual servers very much so I'm afraid this is very much a grey area for me. Any help would be very much appreciated.

    Read the article

  • Help me please with this error

    - by Brandon
    I setup IIS. I moved my folder with all the files to the IIS directory. Now when I go to http://localhost/thefolder I get: An attempt was made to load a program with an incorrect format. (Exception from HRESULT: 0x8007000B) Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.BadImageFormatException: An attempt was made to load a program with an incorrect format. (Exception from HRESULT: 0x8007000B) Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [BadImageFormatException: An attempt was made to load a program with an incorrect format. (Exception from HRESULT: 0x8007000B)] Luxand.FSDK.ActivateLibrary(String LicenseKey) +0 FaceRecognition._Default.Page_Load(Object sender, EventArgs e) in D:\Project Details\Layne Projects\DotNet Project\FaceRecognition\FaceRecognition\Default.aspx.cs:60 System.Web.Util.CalliHelper.EventArgFunctionCaller(IntPtr fp, Object o, Object t, EventArgs e) +25 System.Web.Util.CalliEventHandlerDelegateProxy.Callback(Object sender, EventArgs e) +42 System.Web.UI.Control.OnLoad(EventArgs e) +132 System.Web.UI.Control.LoadRecursive() +66 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +2428

    Read the article

  • The Server Fault Wiki of recommended practices [migrated]

    - by Avery Payne
    So I've noticed that there are several recommendations on basic practices on Server Fault, but there doesn't seem to be a cohesive view as to how those recommendations would all fit together. So I thought I would lump these together as a kind of mental exercise to see what the "ServerFault Community IT Department" would look like if it were implemented. This would give a few things: it would make a reasonable wiki (in the true wiki spirit of many contributions), it would provide several links to well-vetted practices, and it would be kind of fun to see what the amalgamation would look like. And who knows, it may even point out some interesting issues between different forms of "best practices", although I would be stunned if there was a conflict hidden in there someplace... Add your favorites from Server Fault as answers, and I'll re-edit this section with the results. Here's a few catagories to collect different ideas together. Hardware Configuration(s) Server room configuration. Server room temperature Firmware Updates and Scheduling Storage Configuration(s) Selecting a NAS box Linux: Dealing with /tmp Linux: Install apps in /var or /opt? Network Configuration(s) checking DNS health and compliance Security Practice(s) Password (General) Best Practices Password sharing methods Windows Update Updating Windows Servers that are hosts for VMs Network Service(s) User Service(s) User Naming & Deletion Upgrade Process(es) Disaster Recovery Checking Backups Documenting an outage for a post-mortem review Last Edit: 2010-02-17

    Read the article

  • Why does notepad crash on desktop files in the save-as dialog?

    - by deepc
    Here's a puzzling problem - maybe somebody has an idea. Right now I am out of ideas. On Win7 64bit, the following crashes Notepad: On Desktop, right click, select "New | Text Document". This creates "New Text Document.txt". Right click on that file, select "Edit". This opens notepad with the empty file. Select "File | Save as": Notepad crashes and Win7 reports that "Notepad has stopped working". Now, move the file to c:\temp and repeat steps 2 and 3: no crash this time and the save-as dialog appears normally. I can create similar steps for the "open" dialog. Things I have tried: Safe mode - does not work, same problem Create a new user and try again logged in as that user - no crash Name file differently, or create elsewhere and then move to desktop - same problem Use Wordpad instead - same problem Review shell extensions with ShellExView - nothing extraordinary here Stare at the event log entries for each of the crashes. Does not enlighten me. At time of crash look at the process explorer stack view. Hangs at a function "TaskDialog". sfc.exe /scannow repaired some files but the problem persists. This is how the event log entries look like: Log Name: Application Source: Application Error Date: 14.12.2010 00:33:48 Event ID: 1000 Task Category: (100) Level: Error Keywords: Classic User: N/A Description: Faulting application name: NOTEPAD.EXE, version: 6.1.7600.16385, time stamp: 0x4a5bc9b3 Faulting module name: COMCTL32.dll, version: 6.10.7600.16661, time stamp: 0x4c6f6e4b Exception code: 0xc000041d Fault offset: 0x00000000000db770 Faulting process id: 0x198 Faulting application start time: 0x01cb9b1e140ab92a Faulting application path: C:\Windows\system32\NOTEPAD.EXE Faulting module path: C:\Windows\WinSxS\amd64_microsoft.windows.common-controls_6595b64144ccf1df_6.0.7600.16661_none_fa62ad231704eab7\COMCTL32.dll What else should I try, short of dumping my user and starting over with a new profile? Thanks...

    Read the article

  • certificate working on IP but not on URL

    - by Stephan
    I asked this question on stackoverflow, and I've been suggested to repost it here. I have a problem accessing my site (on https) with IEMobile 9 (WP 7.5). It says it's got problem with the certificate, as if it wasn't valid. Everything works on any other browser or platform I tested (android (several phones and a galaxy tab with stock browser, firefox, opera, dolphin), iOS (iphone and ipad with safari and chrome), an old nokia with symbian, windows 7, linux and mac). To try to solve this I saved the certificate (.cer) on the server and accessed it from the phone browser. It always complained except when I accessed it through the server IP (192.168.xx.xx). At that point it (said it) installed correctly the certificate. If then I try to access the index.html still using the IP all works fine and it doesn't complain about the certificate. If, though, I try to access the index using the actual URL (blah.myblah.com), it complains again about the certificate, as if it wasn't installed! It isn't a problem of DNS, cause that's up and serving the right ip, and the phone is correctly setup to use it. The certificate is signed by geotrust/rapidssl for *.myblah.com.

    Read the article

  • router only assigns small number of IPs

    - by Liam Coates
    Been having a problem with my router for a while now, might just be because it is really old but here's the problem: If a lot of computers are connected to my home network someone will get disconnected. They are assigned IPs and it seems like at a certain point (and I don't know how many) you either get assigned the same IP as someone else or something else is happening and you get disconnected - until i soft reset it and it works again which takes 30 secs. I'd say my tablet, my PC, my sisters iPad, 2 laptops and a netbook is the most that can be connected at one time so that is 6 but that should be fine. The only way I know this is the problem is because I turned on my tablet and I was online on my PC, got disconnected but my tablet was still connected, this is just after i turned the tablet on so I know my router is having difficulty with IPs, it is like it assigned the same IP to the tablet which then clashed with my desktop and knocked me off. I see that sometimes the following solves it as well so I wrote a batch file with a menu to execute these commands as I have to do it so often. ipconfig /release ipconfig /flushdns ipconfig /renew Any ideas? Or shall I just get a new router as this one is old and maybe can't handle giving out that many IPs? Cheers!

    Read the article

  • Why should main() be short?

    - by Stargazer712
    I've been programming for over 9 years, and according to the advice of my first programming teacher, I always keep my main() function extremely short. At first I had no idea why. I just obeyed without understanding, much to the delight of my professors. After gaining experience, I realized that if I designed my code correctly, having a short main() function just sortof happened. Writing modularized code and following the single responsibility principle allowed my code to be designed in "bunches", and main() served as nothing more than a catalyst to get the program running. Fast forward to a few weeks ago, I was looking at Python's souce code, and I found the main() function: /* Minimal main program -- everything is loaded from the library */ ... int main(int argc, char **argv) { ... return Py_Main(argc, argv); } Yay python. Short main() function == Good code. Programming teachers were right. Wanting to look deeper, I took a look at Py_Main. In its entirety, it is defined as follows: /* Main program */ int Py_Main(int argc, char **argv) { int c; int sts; char *command = NULL; char *filename = NULL; char *module = NULL; FILE *fp = stdin; char *p; int unbuffered = 0; int skipfirstline = 0; int stdin_is_interactive = 0; int help = 0; int version = 0; int saw_unbuffered_flag = 0; PyCompilerFlags cf; cf.cf_flags = 0; orig_argc = argc; /* For Py_GetArgcArgv() */ orig_argv = argv; #ifdef RISCOS Py_RISCOSWimpFlag = 0; #endif PySys_ResetWarnOptions(); while ((c = _PyOS_GetOpt(argc, argv, PROGRAM_OPTS)) != EOF) { if (c == 'c') { /* -c is the last option; following arguments that look like options are left for the command to interpret. */ command = (char *)malloc(strlen(_PyOS_optarg) + 2); if (command == NULL) Py_FatalError( "not enough memory to copy -c argument"); strcpy(command, _PyOS_optarg); strcat(command, "\n"); break; } if (c == 'm') { /* -m is the last option; following arguments that look like options are left for the module to interpret. */ module = (char *)malloc(strlen(_PyOS_optarg) + 2); if (module == NULL) Py_FatalError( "not enough memory to copy -m argument"); strcpy(module, _PyOS_optarg); break; } switch (c) { case 'b': Py_BytesWarningFlag++; break; case 'd': Py_DebugFlag++; break; case '3': Py_Py3kWarningFlag++; if (!Py_DivisionWarningFlag) Py_DivisionWarningFlag = 1; break; case 'Q': if (strcmp(_PyOS_optarg, "old") == 0) { Py_DivisionWarningFlag = 0; break; } if (strcmp(_PyOS_optarg, "warn") == 0) { Py_DivisionWarningFlag = 1; break; } if (strcmp(_PyOS_optarg, "warnall") == 0) { Py_DivisionWarningFlag = 2; break; } if (strcmp(_PyOS_optarg, "new") == 0) { /* This only affects __main__ */ cf.cf_flags |= CO_FUTURE_DIVISION; /* And this tells the eval loop to treat BINARY_DIVIDE as BINARY_TRUE_DIVIDE */ _Py_QnewFlag = 1; break; } fprintf(stderr, "-Q option should be `-Qold', " "`-Qwarn', `-Qwarnall', or `-Qnew' only\n"); return usage(2, argv[0]); /* NOTREACHED */ case 'i': Py_InspectFlag++; Py_InteractiveFlag++; break; /* case 'J': reserved for Jython */ case 'O': Py_OptimizeFlag++; break; case 'B': Py_DontWriteBytecodeFlag++; break; case 's': Py_NoUserSiteDirectory++; break; case 'S': Py_NoSiteFlag++; break; case 'E': Py_IgnoreEnvironmentFlag++; break; case 't': Py_TabcheckFlag++; break; case 'u': unbuffered++; saw_unbuffered_flag = 1; break; case 'v': Py_VerboseFlag++; break; #ifdef RISCOS case 'w': Py_RISCOSWimpFlag = 1; break; #endif case 'x': skipfirstline = 1; break; /* case 'X': reserved for implementation-specific arguments */ case 'U': Py_UnicodeFlag++; break; case 'h': case '?': help++; break; case 'V': version++; break; case 'W': PySys_AddWarnOption(_PyOS_optarg); break; /* This space reserved for other options */ default: return usage(2, argv[0]); /*NOTREACHED*/ } } if (help) return usage(0, argv[0]); if (version) { fprintf(stderr, "Python %s\n", PY_VERSION); return 0; } if (Py_Py3kWarningFlag && !Py_TabcheckFlag) /* -3 implies -t (but not -tt) */ Py_TabcheckFlag = 1; if (!Py_InspectFlag && (p = Py_GETENV("PYTHONINSPECT")) && *p != '\0') Py_InspectFlag = 1; if (!saw_unbuffered_flag && (p = Py_GETENV("PYTHONUNBUFFERED")) && *p != '\0') unbuffered = 1; if (!Py_NoUserSiteDirectory && (p = Py_GETENV("PYTHONNOUSERSITE")) && *p != '\0') Py_NoUserSiteDirectory = 1; if ((p = Py_GETENV("PYTHONWARNINGS")) && *p != '\0') { char *buf, *warning; buf = (char *)malloc(strlen(p) + 1); if (buf == NULL) Py_FatalError( "not enough memory to copy PYTHONWARNINGS"); strcpy(buf, p); for (warning = strtok(buf, ","); warning != NULL; warning = strtok(NULL, ",")) PySys_AddWarnOption(warning); free(buf); } if (command == NULL && module == NULL && _PyOS_optind < argc && strcmp(argv[_PyOS_optind], "-") != 0) { #ifdef __VMS filename = decc$translate_vms(argv[_PyOS_optind]); if (filename == (char *)0 || filename == (char *)-1) filename = argv[_PyOS_optind]; #else filename = argv[_PyOS_optind]; #endif } stdin_is_interactive = Py_FdIsInteractive(stdin, (char *)0); if (unbuffered) { #if defined(MS_WINDOWS) || defined(__CYGWIN__) _setmode(fileno(stdin), O_BINARY); _setmode(fileno(stdout), O_BINARY); #endif #ifdef HAVE_SETVBUF setvbuf(stdin, (char *)NULL, _IONBF, BUFSIZ); setvbuf(stdout, (char *)NULL, _IONBF, BUFSIZ); setvbuf(stderr, (char *)NULL, _IONBF, BUFSIZ); #else /* !HAVE_SETVBUF */ setbuf(stdin, (char *)NULL); setbuf(stdout, (char *)NULL); setbuf(stderr, (char *)NULL); #endif /* !HAVE_SETVBUF */ } else if (Py_InteractiveFlag) { #ifdef MS_WINDOWS /* Doesn't have to have line-buffered -- use unbuffered */ /* Any set[v]buf(stdin, ...) screws up Tkinter :-( */ setvbuf(stdout, (char *)NULL, _IONBF, BUFSIZ); #else /* !MS_WINDOWS */ #ifdef HAVE_SETVBUF setvbuf(stdin, (char *)NULL, _IOLBF, BUFSIZ); setvbuf(stdout, (char *)NULL, _IOLBF, BUFSIZ); #endif /* HAVE_SETVBUF */ #endif /* !MS_WINDOWS */ /* Leave stderr alone - it should be unbuffered anyway. */ } #ifdef __VMS else { setvbuf (stdout, (char *)NULL, _IOLBF, BUFSIZ); } #endif /* __VMS */ #ifdef __APPLE__ /* On MacOS X, when the Python interpreter is embedded in an application bundle, it gets executed by a bootstrapping script that does os.execve() with an argv[0] that's different from the actual Python executable. This is needed to keep the Finder happy, or rather, to work around Apple's overly strict requirements of the process name. However, we still need a usable sys.executable, so the actual executable path is passed in an environment variable. See Lib/plat-mac/bundlebuiler.py for details about the bootstrap script. */ if ((p = Py_GETENV("PYTHONEXECUTABLE")) && *p != '\0') Py_SetProgramName(p); else Py_SetProgramName(argv[0]); #else Py_SetProgramName(argv[0]); #endif Py_Initialize(); if (Py_VerboseFlag || (command == NULL && filename == NULL && module == NULL && stdin_is_interactive)) { fprintf(stderr, "Python %s on %s\n", Py_GetVersion(), Py_GetPlatform()); if (!Py_NoSiteFlag) fprintf(stderr, "%s\n", COPYRIGHT); } if (command != NULL) { /* Backup _PyOS_optind and force sys.argv[0] = '-c' */ _PyOS_optind--; argv[_PyOS_optind] = "-c"; } if (module != NULL) { /* Backup _PyOS_optind and force sys.argv[0] = '-c' so that PySys_SetArgv correctly sets sys.path[0] to '' rather than looking for a file called "-m". See tracker issue #8202 for details. */ _PyOS_optind--; argv[_PyOS_optind] = "-c"; } PySys_SetArgv(argc-_PyOS_optind, argv+_PyOS_optind); if ((Py_InspectFlag || (command == NULL && filename == NULL && module == NULL)) && isatty(fileno(stdin))) { PyObject *v; v = PyImport_ImportModule("readline"); if (v == NULL) PyErr_Clear(); else Py_DECREF(v); } if (command) { sts = PyRun_SimpleStringFlags(command, &cf) != 0; free(command); } else if (module) { sts = RunModule(module, 1); free(module); } else { if (filename == NULL && stdin_is_interactive) { Py_InspectFlag = 0; /* do exit on SystemExit */ RunStartupFile(&cf); } /* XXX */ sts = -1; /* keep track of whether we've already run __main__ */ if (filename != NULL) { sts = RunMainFromImporter(filename); } if (sts==-1 && filename!=NULL) { if ((fp = fopen(filename, "r")) == NULL) { fprintf(stderr, "%s: can't open file '%s': [Errno %d] %s\n", argv[0], filename, errno, strerror(errno)); return 2; } else if (skipfirstline) { int ch; /* Push back first newline so line numbers remain the same */ while ((ch = getc(fp)) != EOF) { if (ch == '\n') { (void)ungetc(ch, fp); break; } } } { /* XXX: does this work on Win/Win64? (see posix_fstat) */ struct stat sb; if (fstat(fileno(fp), &sb) == 0 && S_ISDIR(sb.st_mode)) { fprintf(stderr, "%s: '%s' is a directory, cannot continue\n", argv[0], filename); fclose(fp); return 1; } } } if (sts==-1) { /* call pending calls like signal handlers (SIGINT) */ if (Py_MakePendingCalls() == -1) { PyErr_Print(); sts = 1; } else { sts = PyRun_AnyFileExFlags( fp, filename == NULL ? "<stdin>" : filename, filename != NULL, &cf) != 0; } } } /* Check this environment variable at the end, to give programs the * opportunity to set it from Python. */ if (!Py_InspectFlag && (p = Py_GETENV("PYTHONINSPECT")) && *p != '\0') { Py_InspectFlag = 1; } if (Py_InspectFlag && stdin_is_interactive && (filename != NULL || command != NULL || module != NULL)) { Py_InspectFlag = 0; /* XXX */ sts = PyRun_AnyFileFlags(stdin, "<stdin>", &cf) != 0; } Py_Finalize(); #ifdef RISCOS if (Py_RISCOSWimpFlag) fprintf(stderr, "\x0cq\x0c"); /* make frontend quit */ #endif #ifdef __INSURE__ /* Insure++ is a memory analysis tool that aids in discovering * memory leaks and other memory problems. On Python exit, the * interned string dictionary is flagged as being in use at exit * (which it is). Under normal circumstances, this is fine because * the memory will be automatically reclaimed by the system. Under * memory debugging, it's a huge source of useless noise, so we * trade off slower shutdown for less distraction in the memory * reports. -baw */ _Py_ReleaseInternedStrings(); #endif /* __INSURE__ */ return sts; } Good God Almighty...it is big enough to sink the Titanic. It seems as though Python did the "Intro to Programming 101" trick and just moved all of main()'s code to a different function called it something very similar to "main". Here's my question: Is this code terribly written, or are there other reasons to have a short main function? As it stands right now, I see absolutely no difference between doing this and just moving the code in Py_Main() back into main(). Am I wrong in thinking this?

    Read the article

  • How to unblacklist an IP at Google?

    - by DJRayon
    I own a small business with two servers for webhosting. When setting up the primary (CentOS 5.5 + WHM, secondary is WHM DNS Only) server I kinda messed up the firewall, so the hackers could send stuff from my server. My primary IP is x.y.29.218. Anyway - I got blacklisted in several places, but now those blacklistings are gone. For a week or so, but Google still has my IP blacklisted. I handling serious damages because of that. Many clients want to switch from my hosting, etc. I've fixed the hole with CSF firewall SMTP_BLOCK option and enabled also the WHM SMTP TEAK Currently all I see from the Main Email View Mail Statistics (Errors section) in WHM is rows and rows of the following message removed-the-email-address-for-security R=lookuphost T=remote_smtp: SMTP error from remote mail server after end of data: host aspmx.l.google.com [a.b.39.27]: 550-5.7.1 [x.y.29.218 1] Our system has detected an unusual rate of\n550-5.7.1 unsolicited mail originating from your IP address. To protect our\n550-5.7.1 users from spam, mail sent from your IP address has been blocked.\n550-5.7.1 Please visit http://www.google.com/mail/help/bulk_mail.html to review\n550 5.7.1 our Bulk Email Senders Guidelines. h24si3868764fas.171 What are my options? I have one IP free. How can I configure Exim to send mail from that IP? My brain is like constantly blowing up because of this problem. Please someone, who has any knowledge how to deal with the current situation, please give me some kind of help - any help, suggestions, etc. I've tried everything I know, and I still don't know much, because this is the first time (I just started to webhost, etc) I deal with real physical servers not some kind of pre-setup VPS solution. Many - many thanks, whoever has time to offer some help.

    Read the article

  • Is the APC BR700G UPS (or similar) compatible with Active PFC power supplies?

    - by David Zaslavsky
    I'm looking at getting a UPS for my home computer. So far the APC BR700G looks very promising, except for one thing: one of the reviews on Newegg says that this UPS does not work with a power supply with Active PFC. Pros: Unit looks great, built well, very heavy, was excited to use it. Cons: Didn't research enough - many newer power supplies like my corsair 750w (and yes dells and other mainstreamers sell them too) that I bought last year have a feature called active pfc (power factor corrected). The signal for this backup battery doesn't fully support that feature and can cause issues. You can find an article on APCs site if you search their user forums for PFC. And the power supply in my computer is, in fact, an Active PFC PSU. I've already found one answer on this site claiming that it's not an issue, that "most quality supplies these days have PFC and work just fine with a UPS." That disagrees with the review on Newegg. Can someone explain this discrepancy? Also, what is it exactly about a UPS that makes it incompatible with an Active PFC PSU? (if anything) Is there some way to tell based on the technical specifications, or do I just have to hunt for reviews online to avoid wasting my money? While any input would be appreciated, I would prefer to get an answer from someone with actual experience with similar UPS's and Active PFC power supplies, who can tell me whether it works or not.

    Read the article

  • DVD drive won't work after installing software

    - by Dan
    DVD drive was already region-free but for some reason would not play a certain DVD as it was the "wrong region". This is the first time I've played a DVD on the drive, but I've imported a lot of CDs before and they always worked fine, even CDs bought from the USA (I live in the UK). To get around this, I downloaded a piece of software called "DVD Region Killer". (Clicking the link won't start the download, so go ahead and check it.) After this, the drive isn't recognised. It won't show up in "My Computer", and when I insert a disc it will start to whir but not take action, i.e. iTunes won't recognise that I have put a CD in. In the Device Manager, the drive shows up with a caution-sign. The device status reads: Windows cannot start this hardware device because its configuration information (in the registry) is incomplete or damaged. (Code 19) Disabling, uninstalling and reinstalling does not help. Clearly the software download is the issue, but it is difficult to remove. The only files I can find in Program Files are: C:\Program Files (x86)\Elaborate Bytes\DVD Region Killer which contains a changelog and a HTML document which has no info on uninstalling. It doesn't show up on "Add or Remove Programs", or even as a background process when I press ctrl-alt-del. Apparently it has no interface as such, and can be accessed by an icon in the system tray, (see review in link) but I don't see the icon. If it helps to know, I have a Dell Inspiron running Windows 8 64-bit, and the model of the DVD drive is: MATSHITA DVD+-RW UJ8C2 Thanks in advance.

    Read the article

  • IIS and ASP.NET

    - by sam
    i'm trying to add asp.net feature on windows 7 i tried to turn it on using turn windows features on or off but it fails every time so i download web platform installer and try it that way and it fails also next i uninstall .net framework 4 restart again! and reinstall it and try again the previous steps but it fails the same i need this installed so i can view it on iis7 anyone know what i can do with this to get it working i've searched and searched and everything fails i get this error on the web platform installer Failed with 0x80070643 – Fatal Error during installation please help i cant do my work with out it working :( ok i did a few things now get this error Server Error in '/pulse' Application. Parser Error Description: An error occurred during the parsing of a resource required to service this request. Please review the following specific parse error details and modify your source file appropriately. Parser Error Message: Could not load type 'pulsesite.MvcApplication'. Source Error: Line 1: <%@ Application Codebehind="Global.asax.vb" Inherits="pulsesite.MvcApplication" Language="VB" % Source File: /pulse/global.asax Line: 1 Version Information: Microsoft .NET Framework Version:4.0.30319; ASP.NET Version:4.0.30319.1 i know its ust about changing the code but i'm not good with c# anyone know how?

    Read the article

  • Setting up VPN with Snow Leopard Server and Linksys router

    - by SueP
    I'd like to get VPN going so I can log in to the office securely from home. I'm using Snow Leopard machines everywhere, and currently have Airport Extremes set up at home and at the office. I have a mac mini with Snow Leopard Server that I'm going to move to the office to act as my server. I just bought a Linksys 4-port router because it says it does VPN (model RVS4000). My problem is, I don't have a clue how to set this thing up, and the more reading I do, the more confused I get. Do I need two of these routers, one at each end? My laptop and iPad claim they can do VPN, so I was assuming I only needed one VPN router? At this point, I literally don't know what questions to ask, or where to plug this thing in. Presumably, between the modem and the airport, but...? If somebody can walk me thru some really basic setup, I'd be very grateful. Right now, I feel like going outside and screaming for a while. But that might attract the local cougar, and after the prints I saw on the arena this afternoon, I don't want to draw its attention. :-)

    Read the article

  • Looking for Remote Control that works with everything (even Windows 7 Media Center)

    - by T Reddy
    Using my Google-Fu, it seems that the most basic of things one gets with any DVR is the remote control. Had I known it would be difficult just to get a consumer IR receiver for Windows 7 I may not have bothered to build an HTPC. But too late, I already have the HTPC ready to go (minus the CETON card...) So I'm moving away from TiVo, I hate paying the monthly fees and my box is ancient. I'm looking for these solutions to my HTCP setup...I want to: Switch audio from HDMI to SPDIF via the remote control (i.e., switch from TV to Receiver) (as a side note, the built-in audio on the mobo has software to do this). Pressing the volume button on the remote will always change the TV's volume (or the Receiver's if possible) and NOT the PC's volume. The remote/receiver works well around 25 feet. Bonus if the IR Receiver can work with my existing TiVo remote (or other remotes laying around the house) I read a review of the Bluetooth TiVo remote...it sounds promising...but I'm not sure if it is great for Windows 7 HTPC?

    Read the article

  • HELP PLEASE!!!! External component has thrown an exception. ASP.NET ASPX PAGE POST

    - by Brandon
    I have an aspx page that communicates with a webservice I have. It connects to an SQL Server database on my virtual dedicated server. With just a little usage, I get this error External component has thrown an exception. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Runtime.InteropServices.SEHException: External component has thrown an exception. Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [SEHException (0x80004005): External component has thrown an exception.] Luxand.FSDK.Initialize(String DataFilesPath) +0 WebService.onLoad() +70 WebService..ctor() +91 facematch.btn_submit_Click(Object sender, EventArgs e) +218 System.Web.UI.WebControls.Button.OnClick(EventArgs e) +105 System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument) +107 System.Web.UI.WebControls.Button.System.Web.UI.IPostBackEventHandler.RaisePostBackEvent(String eventArgument) +7 System.Web.UI.Page.RaisePostBackEvent(IPostBackEventHandler sourceControl, String eventArgument) +11 System.Web.UI.Page.RaisePostBackEvent(NameValueCollection postData) +33 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +1746

    Read the article

  • Are there any disadvantages of having a "free fall sensor" on a hard disk drive?

    - by therobyouknow
    This is a general question that came out of a specific comparison between the Western Digital Scorpio WD3200BEKT and Western Digital Scorpio WD3200BJKT (which is the same as the former but with a free fall sensor.) Note: I'm not asking for a review or appraisal of these specific drives, as the general question does apply on other brands as well. Though your input would help my decision. To break down the general question in order to answer it, I would be looking for comments on things like: if it's necessary to have differing physical dimensions between free fall sensor drives and those without, e.g. does it make it any thicker, and therefore reduce the systems where it can be installed - particularly smaller laptops? does it actually make the system less reliable - because of false alarms whereby the drive thought the laptop was falling but it wasn't? I suppose that the fact that a manufacturer produces both drives with and without free fall sensors says something about possible disadvantages. Or it could be standard marketing techniques where by making drives with and without results in larger sales volume than just those with the feature alone.

    Read the article

  • How to set up simple VPN for secure Internet connections over unencrypted Wi-Fi on Windows?

    - by Senseful
    I'm looking for a solution similar to the one in this question, except that I don't have a linux computer. I have windows computers that could be set up to accept VPN connections. Preferably I want to set this up on either Windows Server 2003 or Windows XP. I'd like to connect different devices (e.g. iPhone, iPad, laptops, etc.) that are on open unsecure wireless networks (e.g. the one's you see at places like Starbucks) to this VPN to ensure that all my data is secure. I found an article that shows that you can enable VPN connections on Windows XP. After following those steps, though, I'm not sure what to do. Which ports do I open on my firewall? Which VPN settings do I use on my devices such as the iPhone? Do I use L2TP, PPTP, or IPSec? What's the difference between these? Are there any other steps missing in that tutorial? I'm hoping that since Windows has this built in feature, that it will be much simpler to set up rather than having to deal with setting up something such as OpenVPN. If I follow those settings and enable port forwarding on port 1723, and then use the following settings on the iPhone: PPTP (IP Address) RSA SecurID: Off Encryption Level: Auto Send All Traffic: On Proxy: Off It shows "Connecting..." then "Disconnecting..." and the following error message: VPN Configuration A connection could not be established to the PPP server. Try reconnecting. If the problem continues, verify your settings and contact your Administrator. I'm using a user account that I enabled privileges to in the VPN settings on the Windows machine.

    Read the article

  • Broad Band LAN connection through existing 6 wire phone line ( no phone connected )

    - by Paul Taylor
    I have an (up to but never achieved ) 10 mb broadband signal coming into my house along the telephone line. The modem then connects the broadband signal via a LAN connection and Wi-Fi signal to my computers and iPad. My workshop desk is 54 yards (approx. 50m) downhill from the modem (part of a separate building) – too far to give a good direct signal. The inside corner of the workshop (by a window) receives a weak signal. I have a disconnected telephone cable consisting of 6 wires going from the house to the workshop. The telephone is no longer used in the workshop - we use our mobile number for business calls. A broad band signal using the cable would not have to share with a phone. What would be the most economic price/efficient way to get the broadband signal to the workshop? I am writing in hope that since the telephone didn't need the six wires, an Ethernet connection might be similar and not need all the eight wires for a LAN connection. In theory could use the telephone wire to pull an Ethernet cable trough the underground pipe but I doubt if the cable would survive the strain. The broad band connection in the workshop does not have to have network facility. My skill level is high enough to do house wiring, plumbing and gas fitting; so given any sound advice and a wiring diagram or instructions I can probably work out the rest myself.

    Read the article

  • Diagnosing "The specified module could not be found" on IIS7 with ASP.Net

    - by Baldy
    I am migrating some web apps from a windows 2003 server with IIS6 server to a Windows server 2008 R2 server with IIS7. One of the apps, which runs on asp.net v2.0 using forms authentication will not load. It gives me the following error... The specified module could not be found. (Exception from HRESULT: 0x8007007E) Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.IO.FileNotFoundException: The specified module could not be found. (Exception from HRESULT: 0x8007007E) Now i fully understand that the app cannot load some kind of resource due to a FileNotFoundException, but i am struggling to diagnose exactly where in the application this is happening, as it does not tell me what the module is, nor what file it is looking for. I have enabled failed request tracing and i get back a complete request trace, yet i cannot find anything that gives me detail on this specific error, or the module involved. Any advice on diagnosing the root cause of the issue would be greatly appreciated.

    Read the article

  • How to set up mysql storage for certain rsyslog input matches?

    - by ylluminate
    I'm draining various logs from Heroku to an rsyslog linux (ubuntu) server and am starting to have a little more to bite off than I can chew in terms of working with my log histories. I am needing to be able drill back in time based on more flexible details and more flexible access than what the standard syslog file(s) provide. I'm thinking that logging to mysql may be the correct approach, but how do I set this up such that it pulls only certain log entries into a table based on an identified? For example, I see a long hex string identifying each log entry from a certain Heroku app instance. I assume that I can just pipe those into the mysql socket vs ALL rsyslog input into mysql... Could someone please direct me to a resource that can walk me through the process of setting something like this up or simply provide some details that can help? I have 15+ years of Unix experience so I just need some nudging in the right direction as I've not really done a tremendous amount of work with syslog daemons previously in terms of pooling various servers into one. Additionally, I'd be interested in any log review tools that could make drilling through log arrangements like this more handy for developers.

    Read the article

  • Do eSATA HDD docking stations have a capacity limit?

    - by Michael Kjörling
    I'm looking at perhaps buying an eSATA docking station to be able to easily plug in and unplug hard disk drives, particularly but not necessarily only for backup purposes. Note: This is not a hardware shopping recommendation question. Please don't vote to close it as such. Looking at different models, I find for example this page detailing the Deltaco SI-7908SUS which specifically states "storage capacity: 1.5 TB" as well as "pictured hard disk not included, only for illustration". A customer review specifically mentions that it does not work with 3 TB drives, although does not go into any detail such as OS, drive model, etc. From a brief glance, the vendor's web site does not appear to say either way. Then there is the quite similar Deltaco SI-7908B3 which boasts on the box "all 2.5" and 3.5" HDD/SSD compatible". My question is: Why would what basically amounts to a SATA/eSATA adapter have any say in what storage capacity devices are supported? Does it? Assuming the OS supports the full capacity of the drive, why should introducing another (not even a different, really) connector change anything? Bonus question: Might it make a difference if the docking station exposes multiple interfaces (such as in the case of for example the SI-7908SUS exposing USB 2.0 and eSATA)? (I still think it shouldn't, but it'd be nice to have it confirmed.)

    Read the article

  • ApplicationPoolIdentity IIS 7.5 to SQL Server 2008 R2 not working.

    - by Jack
    I have a small ASP.NET test script that opens a connection to a SQL Server database on another machine in the domain. It isn't working in all cases. Setup: IIS 7.5 under W2K8R2 trying to connect to a remote SQL Server 2008 R2 instance. All machines are in the same domain. Using the ApplicationPoolIdentity for the web site it fails to connect to the SQL Server with the following: Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Data.SqlClient.SqlException: Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. However if I switch the Process Model Identity to NETWORK SERVICE or my domain account the database connection is successful. I've granted the \$ access in SQL Server. I am not doing any sort of authentication on the web site, it is just a simple script to open a connection to a database to make sure it works. I have Anonymous Authentication enabled and set to use the Application pool identity. How do I make this work? Why is the ApplicationPoolIdentity trying to use ANONYMOUS LOGON? Better yet, how do I make it stop using the Anonymous logon?

    Read the article

< Previous Page | 283 284 285 286 287 288 289 290 291 292 293 294  | Next Page >