Search Results

Search found 13011 results on 521 pages for 'catch block'.

Page 289/521 | < Previous Page | 285 286 287 288 289 290 291 292 293 294 295 296  | Next Page >

  • Does C99 guarantee that arrays are contiguous ?

    - by kriss
    Following an hot comment thread in another question, I came to debate of what is and what is not defined in C99 standard about C arrays. Basically when I define a 2D array like int a[5][5], does the standard C99 garantee or not that it will be a contiguous block of ints, can I cast it to (int *)a and be sure I will have a valid 1D array of 25 ints. As I understand the standard the above property is implicit in the sizeof definition and in pointer arithmetic, but others seems to disagree and says casting to (int*) the above structure give an undefined behavior (even if they agree that all existing implementations actually allocate contiguous values). More specifically, if we think an implementation that would instrument arrays to check array boundaries for all dimensions and return some kind of error when accessing 1D array, or does not give correct access to elements above 1st row. Could such implementation be standard compilant ? And in this case what parts of the C99 standard are relevant.

    Read the article

  • Rails 3 - Nested layouts - LocalJumpError

    - by Art Shayderov
    Hi Nested layouts do not work in Rails 3. After I hit this I tried Rails Guides Example on a blank project (both ruby 1.9.1 and 1.8.7). LocalJumpError no block given on line <%= yield :stylesheets %. If you remove this line you will get the same error on the next yield statement. Could someone fix(patch) this? It's probably just a matter of calling block_given? in the right place. That would be great. Thanks Added on 4/3: Rails 3 beta 2 released. Problem fixed.

    Read the article

  • Flash AS3 - Display an error if the XML if incorrect

    - by ongoingworlds
    Hi, I'm creating a flash application which loads in some XML which is generated dynamically from the CMS. I want to display an error in case the XML file isn't formatted correctly. When I test this with incorrectly formatted XML, it will just get to the line myXML = XML(myLoader.data); and then just bomb out. How can I catch the error, display a message to the user, but the flash program to continue as normal. var myXMLURL:URLRequest = new URLRequest(XMLfile); var myLoader:URLLoader = new URLLoader(myXMLURL); myLoader.addEventListener(Event.COMPLETE, xmlLoaded); myLoader.addEventListener(IOErrorEvent.IO_ERROR, xmlFailed); var myXML:XML; //--when the xml is loaded, do this function xmlLoaded(e:Event):void { myXML = XML(myLoader.data); trace("XML = "+myXML); } //--if the xml fails to load, do this function xmlFailed(event:IOErrorEvent):void { errorMsg.text = "The XML file cannot be found" }

    Read the article

  • inherit properties and then change some on particular site (css)

    - by Radek
    I have three menus on this test web site. I am learning css and trying all the menus inherit all properties from menu class. The second one looks different and is not clickable. I am happy with the 3rd one, just want to make it horizontal and change its position bit. Could somebody tell me why the second menu is not click-able? how I can make the third menu vertical? I thought that display: block; for li of the 3rd menu would do the trick but I do not know the css path for that li.

    Read the article

  • Why are my hard drives failing?

    - by WishCow
    I have a small Ubuntu server running at home, with 2 HDDs. There are two software raids (raid1) on the disks, managed by mdadm, which I believe is irrelevant, but mentioning it anyway. Both of the HDDs are Western Digital, and have been used for around 2 years, when one of them started making clicking noises, and died. I figured that maybe it's natural after 2 years, so I bought a new one, and resynced the raid arrays. After about a month, the other drive also died. I didn't get suspicious, since both drives have been bought at the same time, it's not that surprising to see both of them near each other, so I bought another one. So far, 2 old drives failed, and 2 brand new in the system. After one month, one of the new drives died. This is when it started getting suspicious. Since the PC was put together from some really old parts (think AthlonXP), I figured that maybe the motherboard's SATA controller is the culprit. Of course you can't switch parts easily in an old PC like this, so I bought a whole system, new MB, new CPU, new RAM. Took the just failed drive back, since it was under warranty, and got it replaced. So it is up to 2 failed drives from the old ones, and 1 failed drive from the new ones. No problems, for 1 month. After that errors were creeping up again in /var/log/messages, and mdadm was reporting raid array failures. I started tearing my hair out. Everything is new in the system, it's up to the third brand new HDD, it's simply not possible that all of the new drives that I bought were faulty. Let's see what is still common... the cables. Okay, long shot, let's replace the SATA cables. Take HDD back, smile to the guy at the counter and say that I'm really unlucky. He replaces the HDD. I come home, one month passes and one of HDDs fails, again. I'm not joking. Two of the brand new HDDs have failed. Maybe it's a bug in the OS. Let's see what the manufacturer's testing tool says. Download testing tool, burn it to a CD, reboot, leave HDD testing overnight. Test says that the drive is faulty, and I should back up everything, if I still can. I don't know what's happening, but it does not look like a software problem, something is definitely thrashing the HDDs. I should mention now, that the whole system is in a shoebox. Since there are a load of "build your own ikea case" stuff, I thought there shouldn't be any problems throwing the thing in a box, and stuffing it away somewhere. The box is well ventilated, but I thought that just maybe the drives were overheating. There is no other possible answer to this. So I took the HDD back, and got it replaced (for the 3rd time), and bought HDD coolers. And just now, I have heard the sound of doom. click click whizzzzzzzzz. SSH into the box: You have new mail! mail r 1 DegradedArrayEvent on /dev/md0 ... dmesg output: [47128.000051] ata3: lost interrupt (Status 0x50) [47128.000097] end_request: I/O error, dev sda, sector 58588863 [47128.000134] md: super_written gets error=-5, uptodate=0 [48043.976054] ata3: lost interrupt (Status 0x50) [48043.976086] ata3.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [48043.976132] ata3.00: cmd c8/00:18:bf:40:52/00:00:00:00:00/e1 tag 0 dma 12288 in [48043.976135] res 40/00:00:00:4f:c2/00:00:00:00:00/00 Emask 0x4 (timeout) [48043.976208] ata3.00: status: { DRDY } [48043.976241] ata3: soft resetting link [48044.148446] ata3.00: configured for UDMA/133 [48044.148457] ata3.00: device reported invalid CHS sector 0 [48044.148477] ata3: EH complete Recap: No possibility of overheating 6 drives have failed, 4 of those have been brand new. I'm not sure now that the original two have been faulty, or suffered the same thing that the new ones. There is nothing common in the system, apart from the OS which is Ubuntu Karmic now (started with Jaunty). New MB, new CPU, new RAM, new SATA cables. No, the little holes on the HDD are not covered I'm crying. Really. I don't have the face to return to the store now, it's not possible for 4 drives to fail under 4 months. A few ideas that I have been thinking: Is it possible that I fuck up something when I partition and resync the drives? Can it be so bad that it physicaly wrecks the drive? (since the vendor supplied tool says that the drive is damaged) I do the partitoning with fdisk, and use the same block size for the raid1 partitions (I check the exact block sizes with fdisk -lu) Is it possible that the linux kernel or mdadm, or something is not compatible with this exact brand of HDDs, and thrashes them? Is it possible that it may be the shoebox? Try placing it somewhere else? It's under a shelf now, so humidity is not a problem either. Is it possible that a normal PC case will solve my problem (I'm going to shoot myself then)? I will get a picture tomorrow. Am I just simply cursed? Any help or speculation is greatly appreciated. Edit: The power strip is guarded against overvoltage. Edit2: I have moved inbetween these 4 months, so the possibility of the cause being "dirty" electricity in both places, is very low. Edit3: I have checked the voltages in the BIOS (couldn't borrow a multimeter), and they are all seem correct, the biggest discrepancy is in the 12V, because it's supplying 11.3. Should I be worried about that? Edit4: I put my desktop PC's PSU into the server. The BIOS reported much more accurate voltage readings, and also it has successfully rebuilt the raid1 array, which took some 3-4 hours, so I feel a little positive now. Will get a new PSU tomorrow to test with that. Also, attaching the picture about the box: (disregard the 3rd drive)

    Read the article

  • Throwing Exception in CTOR and Smart Pointers

    - by David Relihan
    Is it OK to have the following code in my constructor to load an XML document into a member variable - throwing to caller if there are any problems: MSXML2::IXMLDOMDocumentPtr m_docPtr; //member Configuration() { try { HRESULT hr = m_docPtr.CreateInstance(__uuidof(MSXML2::DOMDocument40)); if ( SUCCEEDED(hr)) { m_docPtr->loadXML(CreateXML()); } else { //throw exception to caller } } catch(...) { //throw exception to caller } } Based on Scott Myers RAII implementations in More Effective C++ I believe I am alright in just allowing exceptions to be thrown from CTOR as I am using a smart pointer(IXMLDOMDocumentPtr). Let me know what you think....

    Read the article

  • How to sort a gridview once a radio button is selected

    - by metashockwave
    I'm trying to sort records in the gridview right after a radio button is selected. My approach is with the dataview, but because the dataset variable doesn't survive a round trip to the server, I don't know how to make this happen. please help! Public Sub GetCustomers() db.RunProcedure("usp_customers_get_all") db.doSort(radList.SelectedValue) gvCustomers.DataSource = db.MyView End Sub Protected Sub radList_SelectedIndexChanged(ByVal sender As Object, ByVal e As System.EventArgs) Handles radList.SelectedIndexChanged If radList.SelectedValue = 0 Then db.doSort(0) gvCustomers.DataSource = db.MyView End If If radList.SelectedValue = 1 Then db.doSort(1) gvCustomers.DataSource = db.MyView End If End Sub Public Sub doSort(ByVal strIn As Integer) If strIn = 0 Then MyView.Sort = "lastname, firstname" Else MyView.Sort = "username" End If End Sub Public Sub RunProcedure(ByVal strName As String) Dim objConnection As New SqlConnection(mstrConnection) Dim mdbDataAdapter As New SqlDataAdapter(strName, objConnection) Try mdbDataAdapter.SelectCommand.CommandType = CommandType.StoredProcedure Me.mDataset.Clear() mdbDataAdapter.Fill(mDataset, "tblCustomers") MyView.Table = mDataset.Tables("tblCustomers") Catch ex As Exception Throw New Exception("stored procedure is " & strName.ToString & " error is " & ex.Message) End Try End Sub

    Read the article

  • controlling if exceptions are swallowed by a static boolean

    - by sandis
    So we are a few guys developing this product that is communicating with a really unstable server. It often returns very strange and corrupt data. During testing we want the resulting crashes to be loud, so we discover them. But every other day we need to demonstrate our product for a potential customer. To the customer the errors will go undiscovered if we just swallow them. I am thinking about implementing something like this around all server communication to quickly switch between swallowing exceptions and crashing: try { apiCall(); } catch (Exception e) { if(!SWALLOW_EXCEPTION) { throw e; } } Is this an awesome idea, or can it be done in a better way?

    Read the article

  • Can I ask Postgresql to ignore errors within a transaction

    - by fmark
    I use Postgresql with the PostGIS extensions for ad-hoc spatial analysis. I generally construct and issue SQL queries by hand from within psql. I always wrap an analysis session within a transaction, so if I issue a destructive query I can roll it back. However, when I issue a query that contains an error, it cancels the transaction. Any further queries elicit the following warning: ERROR: current transaction is aborted, commands ignored until end of transaction block Is there a way I can turn this behaviour off? It is tiresome to rollback the transaction and rerun previous queries every time I make a typo.

    Read the article

  • resolving localhost in php so can be views outside VM

    - by DA
    I'm running Windows 7. Within, I'm running Virtualbox and Ubuntu. Within Ubuntu, I'm running Apache and using PHP codeigniter. To reference our CSS and JS files, we use this syntax: <?php echo site_url('css/styles.css'); ?> When viewing the site locally (within Ubuntu VM) that resolves to: http://localhost/styles.css So works fine. The catch is when I access that site from within Windows 7 (for IE testing). To access the site in Windows 7, I refer to the IP address of the VM: http://xx.x.x.x/ That loads the site but, alas, all the site_url variables are still being rewritten as 'localhost'. Said files obviously don't exist on the localhost of my windows 7. Is there a way around this short of just hard-coding relative links in my PHP file?

    Read the article

  • How to get "paster request" to use config host value instead of localhost?

    - by mmartinez
    I'm trying to access my pylons application via cron job to send notifications to my users. The way I'm doing this is by running the application using something like: paster request myconfig.ini /maintenance/do In the actual controller I check for the "paste.command_request" to block public access. Everything works but the only problem is that within the notifications that I send to my users there is a link to their profile and the host is "localhost" which should instead be the domain name of the application. When the notifications are sent from within the served application (say, a user modifies their settings on the site) the notifications have the correct url. I am using mako to render my email tamplates and within the template I am using the "pylons.url" method with "qualified" set to "True". Am I missing something here? Thanks in advance.

    Read the article

  • Ios Parse Login

    - by user3806600
    I am programming an IOS app that will use parse to login a user. Using storyboard I have the login button connected to another view controller with the push segue. Whether the username and password are correct the button selection always goes to the new view controller. I might be doing this all wrong. Any help is appreciated. Here is my code: - (IBAction)signIn:(id)sender { [PFUser logInWithUsernameInBackground:self.emailField.text password:self.passwordField.text block:^(PFUser *user, NSError *error) { if (!error) { [self performSegueWithIdentifier:@"signIn" sender:nil]; } else { // The login failed. Check error to see why. } }]; }

    Read the article

  • translate by replacing words inside existing text

    - by Berry Tsakala
    What are common approaches for translating certain words (or expressions) inside a given text, when the text must be reconstructed (with punctuations and everythin.) ? The translation comes from a lookup table, and covers words, collocations, and emoticons like L33t, CUL8R, :-), etc. Simple string search-and-replace is not enough since it can replace part of longer words (cat dog ? caterpillar dogerpillar). Assume the following input: s = "dogbert, started a dilbert dilbertion proces cat-bert :-)" after translation, i should receive something like: result = "anna, started a george dilbertion process cat-bert smiley" I can't simply tokenize, since i loose punctuations and word positions. Regular expressions, works for normal words, but don't catch special expressions like the smiley :-) but it does . re.sub(r'\bword\b','translation',s) ==> translation re.sub(r'\b:-\)\b','smiley',s) ==> :-) for now i'm using the above mentioned regex, and simple replace for the non-alphanumeric words, but it's far from being bulletproof. (p.s. i'm using python)

    Read the article

  • WCF Client Proxy State

    - by RemotecUk
    Hi, how do I test the state of my proxy before making calls to my WCF service. I have a duplex channel created using a duplex channel factory. Before making any calls to the server I want to check the state of the proxy object created from the channel factory. I saw this in a book... (to be used in immediate window) ? ((ICommunicationObject)flsProxy).State But it gave this exception... Cannot obtain fields or call methods on the instance of type 'System.ServiceModel.ICommunicationObject' because it is a proxy to a remote object. Would be grateful for any ideas how this can be tested, or is it better to just catch exceptions. Thanks.

    Read the article

  • What is the proper way to resolve this Eclipse warning?

    - by Morinar
    I'm trying to clean up some warnings in some old Java code (in Eclipse), and I'm unsure what the proper thing to do is in this case. The block looks more or less like this: java.util.List clipboardFileList = null; if( content.isDataFlavorSupported( DataFlavor.javaFileListFlavor ) ) { try { clipboardFileList = (java.util.List)content.getTransferData( DataFlavor.javaFileListFlavor); } /* Do other crap, etc. */ } The List generates a warning as it isn't parameterized, however, if I parameterize it with <File>, which I'm pretty sure is what it requires, it complains that it can't convert from Object to List<File>. I could merely suppress the unchecked warning for the function, but would prefer to avoid that if there is a "good" solution. Thoughts?

    Read the article

  • Should I throw my own ArgumentOutOfRangeException or let one bubble up from below?

    - by Neil N
    I have a class that wraps List< I have GetValue by index method: public RenderedImageInfo GetValue(int index) { list[index].LastRetrieved = DateTime.Now; return list[index]; } If the user requests an index that is out of range, this will throw an ArgumentOutOfRangeException . Should I just let this happen or check for it and throw my own? i.e. public RenderedImageInfo GetValue(int index) { if (index >= list.Count) { throw new ArgumentOutOfRangeException("index"); } list[index].LastRetrieved = DateTime.Now; return list[index]; } In the first scenario, the user would have an exception from the internal list, which breaks mt OOP goal of the user not needing to know about the underlying objects. But in the second scenario, I feel as though I am adding redundant code. Edit: And now that I think of it, what about a 3rd scenario, where I catch the internal exception, modify it, and rethrow it?

    Read the article

  • Disabling Task manager using c# in OS Hardened machine

    - by srk
    I am using the below code to disable the task manager for a kiosk application which works perfectly public void DisableTaskManager() { RegistryKey regkey; string keyValueInt = "1"; string subKey = "Software\\Microsoft\\Windows\\CurrentVersion\\Policies\\System"; try { regkey = Registry.CurrentUser.CreateSubKey(subKey); regkey.SetValue("DisableTaskMgr", keyValueInt); regkey.Close(); } catch (Exception ex) { MessageBox.Show("DisableTaskManager" + ex.ToString()); } } But when i run this in OS hardened machine i get the following error, DisableTaskManagerSystem.UnauthorizedAccessException: Access to the registry key 'HKey_Current_User\Software\Mictrosoft\Windows\CurrentVersion\Policies\System' is denied. at Microsoft.win32.RegistryKey.win32Error(int32 errorcode, String str) How can i overcome this ? I need to do this for a Kiosk application.

    Read the article

  • Call to C++ COM interface from C# being blocked

    - by dauphic
    I have a C++ DLL that exposes a COM interface. A C# application uses the COM interface. I've recently run into a problem where some calls to the COM interface are taking 500-5000 ms to return, though they should return almost instantly (no longer than 10 ms). Profiling the application shows that all of the delay is being caused by the 'thread being blocked;' no other information is available. There are no locks, etc. in my code, so the blocking has to be occurring internally in the COM/interop code. Only one thread interfaces with the COM DLL. Any ideas what could be causing this, and how I would fix it? EDIT: Further investigation shows that the block is occuring when the C++ returns to the C#.

    Read the article

  • How to get a list of all domains?

    - by AngryHacker
    I'm trying to get all domains that are available in the Windows Login dialog (in the Domain dropdown). I've tried the following code but it only returns the domain I am logged into. Am I missing something? StringCollection domainList = new StringCollection(); try { DirectoryEntry en = new DirectoryEntry("LDAP://"); // Search for objectCategory type "Domain" DirectorySearcher srch = new DirectorySearcher("objectCategory=Domain"); SearchResultCollection coll = srch.FindAll(); // Enumerate over each returned domain. foreach (SearchResult rs in coll) { ResultPropertyCollection resultPropColl = rs.Properties; foreach( object domainName in resultPropColl["name"]) { domainList.Add(domainName.ToString()); } } } catch (Exception ex) { Trace.Write(ex.Message); } return domainList;

    Read the article

  • Shouldn't ObjectInputStream extend FilterInputStream?

    - by Vaibhav Bajpai
    The block quotes are from the Java Docs - A FilterInputStream contains some other input stream, which it uses as its basic source of data, possibly transforming the data along the way or providing additional functionality. A DataInputStream lets an application read primitive Java data types from an underlying input stream in a machine-independent way. The DataInputStream therefore extends FilterInputStream An ObjectInputStream deserializes primitive data and objects previously written using an ObjectOutputStream. However, for some reason the ObjectInputStream does NOT extend FilterInputStream even though it is also reading objects (this time and not primitive types) from the underlying input stream. Here is the branching of the concerned classes. Is there is a design reasoning for the same?

    Read the article

  • Problem updating blog with hibernate?

    - by johnsmith51
    hi, i am having problem updating a blob with hibernate. my model have these getters/setters for hibernate, i.e. internally i deal with byte[] so any getter/setter convert the byte[] to blog. I can create an initial object without problem, but if I try to change the content of the blob, the database column is not updated. I do not get any error message, everything looks fine, except that the database is not updated. /** do not use, for hibernate only */ public Blob getLogoBinaryBlob() { if(logoBinary == null){ return null; } return Hibernate.createBlob(logoBinary); } /** do not use, for hibernate only */ public void setLogoBinaryBlob(Blob logoBinaryBlob) { ByteArrayOutputStream baos = new ByteArrayOutputStream(); try { logoBinary = toByteArrayImpl(logoBinaryBlob, baos); } catch (Exception e) { } }

    Read the article

  • How can I prevent MEF from throwing an exception when an Export is not found?

    - by Kilhoffer
    I have a class with an IList<T> property decorated with the [ImportMany(allowRecomposition = true)] attribute. There are some conditions in which the application might not find any available Exports of the requested type. Right now, it's throwing a CompositionException if no Exports of the requested type are found. I dislike application flow being determined by thrown exceptions, so I would rather not catch and react in this case. Rather, I just want program execution to continue. Is there a flag or something I can set to make this Import optional? I know for single import properties, you can do this: [Import(AllowDefault = true)] but 'AllowDefault' is not an option on the ImportMany attribute.

    Read the article

  • Returning a JSON view in combination with a boolean

    - by Rody van Sambeek
    What i would like to accomplish is that a partiel view contains a form. This form is posted using JQuery $.post. After a successfull post javascript picks up the result and uses JQuery's html() method to fill a container with the result. However now I don't want to return the Partial View, but a JSON object containing that partial view and some other object (Success - bool in this case). I tried it with the following code: [AcceptVerbs(HttpVerbs.Post)] public ActionResult Edit(int id, Item item) { if (ModelState.IsValid) { try { // ... return Json(new { Success = true, PartialView = PartialView("Edit", item) }); } catch(Exception ex) { // ... } } return Json(new { Success = false, PartialView = PartialView("Edit", item) }); } However I don't get the HTML in this JSON object and can't use html() to show the result. I tried using this method to render the partial as Html and send that. However this fails on the RenderControl(tw) method with a: The method or operation is not implemented.

    Read the article

  • Groovy 1.7 changes "final"?

    - by Aaron L. Carlow
    Just started learning Groovy, got the PragProg book "Programming Groovy" and had a problem compiling one of the sample scripts: class GCar2 { final miles = 0 def getMiles() { println "getMiles called" miles } def drive(dist) { if (dist > 0) { miles += dist } } } def car = new GCar2() println "Miles: $car.miles" println 'Driving' car.drive(10) println "Miles: $car.miles" try { print 'Can I see the miles? ' car.miles = 12 } catch (groovy.lang.ReadOnlyPropertyException ex) { println ex.message GroovyCar2.groovy: 20: cannnot access final field or property outside of constructor. @ line 20, column 35. def drive(dist) { if (dist > 0) miles += dist } ^ Groovy versions prior to 1.7 do not give an error. I looked through whatever documentation I could find and did not see the issue discussed. What is going on here? Aaron

    Read the article

  • CFSocketConnectToAddress and unrecognized selector sent to instance

    - by madmik3
    Hello, I am somewhat new to iPhone dev and I have been getting unrecognized selector when I call CFSocketConnectToAddress in this code. I think it might be something basic that I am doing wrong. Any idea? this is the complete error I get. NSInvalidArgumentException unrecognized selector sent to instance 0x3922170 0x3922170 is the calling class. - (BOOL)connect { CFSocketRef mySocket = CFSocketCreate(kCFAllocatorDefault, PF_INET, SOCK_DGRAM,IPPROTO_UDP, 0, socketCallback, NULL); @try { CFDataRef data = (CFDataRef)[_netService addresses]; CFSocketConnectToAddress(mySocket, data, 500); } @catch (NSException * e) { NSLog([e name]); NSLog([e reason]); } //char joke[] = "Why did the chicken cross the road?"; //CFSocketError err = CFSocketSendData(mySocket, joke, (strlen(joke)+1), 10); return true; } void socketCallback ( CFSocketRef s, CFSocketCallBackType callbackType, CFDataRef address, const void *data, void *info) { }

    Read the article

< Previous Page | 285 286 287 288 289 290 291 292 293 294 295 296  | Next Page >