Search Results

Search found 8297 results on 332 pages for 'cmd exe'.

Page 29/332 | < Previous Page | 25 26 27 28 29 30 31 32 33 34 35 36  | Next Page >

  • procdump on w3wp.exe: Only part of a ReadProcessMemory or WriteProcessMemory request was completed

    - by JakeS
    I'm having a problem with an IIS application that occasionally spikes up in CPU usage, and am trying to use procdump to get a memory dump for examination. I'm running "procdump.exe -64 -mA 9999" where 9999 is the pid of the process. But every time I do it, I get an error: Only part of a ReadProcessMemory or WriteProcessMemory request was completed. Doing this also recycles the apppool, relieving the CPU spike, so I can't keep trying until I get it right. Does anyone know what is going wrong? EDIT WITH MORE INFO: So far I've failed to generate a debug dump no matter what tool I try. All of them seem to generate the same sort of error. This is 2008 R2 Datacenter running IIS7 with a 64-bit asp.net web site. My best guess is that something is getting blocked, causing some requests to remain open in IIS and gradually using up resources. If I monitor the worker process using the IIS Manager and view all requests, throughout the day I'll start to see some requests that "stick" and run forever. Some of these are for static files. Some are for aspx pages. I cannot see any "common" reason for them. Every once in a while the app pool starts taking up 100% CPU and the only remedy is to kill it.

    Read the article

  • Makecert.exe hangs

    - by Robert
    I was following the steps in Scott Hanselman's blog post describing how to create a certificate authority and code signing certificate for PowerShell scripts. Initially, I created the certificate authority and a personal certifcate and used it to sign a powershell script successfully. All went as described in the blog post. The problem starts (as most do) when I did something that was (probably) stupid, although it seemed reasonable at the time. I wanted to start over and repeat the process again with a clean slate, so from the mmc certificates snap-in console, I deleted the personal certificate and the certificate authority I created previously. After that any time I try to use makecert, (just as I did the first time around), makecert either hangs or faults (which prompts to end or debug). Did I hose something up by deleting via the certificates snap-in? It didn't complain or warn me that it could be potentially hazardous. Is this just coincidence and something else entirely could be hosed? I have Event Log entries from the times when makecert crashed, which all look very similar; here is one: Log Name: Application Source: Application Error Date: 8/5/2009 3:55:04 PM Event ID: 1000 Task Category: (100) Level: Error Description: Faulting application makecert.exe, version 6.0.6000.16384, time stamp 0x4545910b, faulting module ntdll.dll, version 6.0.6002.18005, time stamp 0x49e03821, exception code 0xc0000005, fault offset 0x00067409, process id 0xe58, application start time 0x01ca160efdf30625. Anyone have any ideas as to what exactly caused this and/or what I can do to fix it. I'm on 32-bit Vista Enterprise w/SP2.

    Read the article

  • Microsoft Security Essentials & MsMpEng.exe hogging resources

    - by Mike
    I've been using MSE for a couple months now, never had a single problem. All of a sudden the process "MsMpEng.exe" will randomly go crazy and hog all my system resources so I can't do anything unless I kill it in the task manager. (I've quit the program for now and my comp is running smooth). When I restart the program, reboot, whatever, it goes off and hogs all the resources again after a couple minutes. If I kill the process it will go away and then come back a couple minutes later and do the same thing. I've scanned with MSE, another antivirus and malware with no probs. Any ideas? Should I uninstall and find something else? The thing is I've liked it so far. I'm running Win7 64-bit. Also, I'm not running any other conflicting security programs. This is the only one on my PC right now. Windows Defender is also off.

    Read the article

  • Cannot Access Local Network Shares (Strange Schannel and lsass.exe issues)

    - by Fake
    When I browse to my own computer's shares by going to \\MYCOMPUTERNAME\ ; I cannot access any of the shares on my LOCAL machine (nor can I access them remotely) and it generates about 40 of the following errors in my system event log: The following fatal alert was generated: 10. The internal error state is 1203. Details: <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event"> <System> <Provider Name="Schannel" Guid="{1F678132-5938-4686-9FDC-C8FF68F15C85}" /> <EventID>36888</EventID> <Version>0</Version> <Level>2</Level> <Task>0</Task> <Opcode>0</Opcode> <Keywords>0x8000000000000000</Keywords> <TimeCreated SystemTime="2011-04-05T13:52:09.144278900Z" /> <EventRecordID>79628</EventRecordID> <Correlation /> <Execution ProcessID="552" ThreadID="672" /> <Channel>System</Channel> <Computer>DEVELOP4.CONTOSO.COM</Computer> <Security UserID="S-1-5-18" /> </System> <EventData> <Data Name="AlertDesc">10</Data> <Data Name="ErrorState">1203</Data> </EventData> </Event> Additonal information: The process that is generating the error is lsass.exe OS: Windows7 Professional x64 Joined to Domain: Yes I was able to access the shares locally in the past I am having the same issue on 3 other computers that have similar configurations Any help would be greatly appreciated, because I have no idea what's wrong. Thanks!

    Read the article

  • Please help me get rid of asmonitor.exe

    - by LCD Fire
    It might be silly and I trully apologize if the question is not apropriate here, but I have really tried and got to nowhere. I have a windows xp startup error which indicates something about asmonitor.exe program from the ActualSpy keylogger. I had installed but removed ActualSpy keylogger using Superantispyware or something close. I have searched the registries and found a asmonitor entry deleted. I looked at startup programs and can not find the asmonitor program. In addition, I searched the c: drive using regular explorer search and searched using ESET NOD32 antivirus. In each case I cannot find the application... I have even looked at startup programs using msinfo32 command. msconfig-startup NOTHING! it drives me crazy! I can't get rid of it. it is still showing up at windows startup! Where do I find this little program? where is it located? I don't want it to keep showing up. I don't want programs that can do it.. or maybe free ones. But I prefer manual solutions. aren't are any?

    Read the article

  • Svchost.exe connecting to different IPs with remote port 445

    - by Coll911
    Im using Windows XP Professional SP2. Whenever I start my Windows, svchost.exe starts connecting to all the possible IPs on LAN like from 192.168.1.2 to 192.168.1.200. The local port ranges from 1000-1099 and the remote port being 445. After it's done with the local IPs, it starts connecting to other random IPs. I tried blocking connections to the port 445 using the local security polices but it didn't work. Is there any possible way I could prevent svchost from connecting to these IPs without involving any firewall installed? My PC slows down due to the load. I scanned my PC with MalwareBytes and found out it was infected with a worm, it's deleted now but still svchost is connecting to the IPs. I also found out that in my Windows Firewall settings, under Internet Control Message Protocol (ICMP), there's a tick on "allow incoming echo request" (usually disabled) which is locked and I can't disable it. Its description is as follows Messages sent to this computer will be repeated back to the sender. This is used for trouble shooting for e.g to ping a machine. Requests of this type are automatically allowed if TCP port 445 is enabled. Any solutions? I can't bear going with the reinstalling Windows phase again.

    Read the article

  • Batch break up after call other batch file

    - by Sven Arno Jopen
    i have the problem, that my batch process breaking up each time after call a other batch file. The batch files are used to run a make process out from IBM Rhapsody. There convert the call from Rhapsody to the Visual Studio tools. So nmake will be called from the batch after make different settings. The scripts aren’t written completely from me, I only adapt theme to run under both windows architecture versions, x86 and x64. The first script (vs2005_make.bat) will be called from Rhapsody and run to the “call” statement. The second script (Vcvars_VisualStudio2005.bat) runs to the end. But the first script isn’t resume working, at this point the process break up without a error message. I'm not very familiar with batch files, this is the first time I make more than simple console commands in a batch file. So I hope I have given all information’s which needed, otherwise ask me. Here the start script (vs2005_make.bat): :: parameter 1 - Makefile which should be used :: parameter 2 - The make target mark @echo off IF "%2"=="" set target=all IF "%2"=="all" set target=all IF "%2"=="build" set target=all IF "%2"=="rebuild" set target=clean all IF "%2"=="clean" set target=clean set RegQry="HKLM\Hardware\Description\System\CentralProcessor\0" REG.exe Query %RegQry% > checkOS.txt Find /i "x86" < CheckOS.txt > StringCheck.txt IF %ERRORLEVEL%==0 ( set arch=x86 ) ELSE ( set arch=x64 ) call "%ProgramFiles%\IBM\Rhapsody752\Share\etc\Vcvars_VisualStudio2005.bat" %arch% IF %ERRORLEVEL%==0 ( set makeflags= nmake /nologo /S /F %1 %target% ) del checkOS.txt del StringCheck.txt exit and here the called script (Vcvars_VisualStudio2005.bat): :: param 1 - Processor architecture @echo off ECHO param 1 = %1 IF %1==x86 ( SET ProgrammPath=%ProgramFiles% ) ELSE IF %1==x64 ( SET ProgrammPath=%ProgramFiles(x86)% ) ELSE ( ECHO Unknowen architectur EXIT /B 1 ) SET VSINSTALLDIR="%ProgrammPath%\Microsoft Visual Studio 8\Common7\IDE" SET VCINSTALLDIR="%ProgrammPath%\Microsoft Visual Studio 8" SET FrameworkDir=C:\WINDOWS\Microsoft.NET\Framework SET FrameworkVersion=v2.0.50727 SET FrameworkSDKDir="%ProgrammPath%\Microsoft Visual Studio 8\SDK\v2.0" rem Root of Visual Studio common files. IF %VSINSTALLDIR%=="" GOTO Usage IF %VCINSTALLDIR%=="" SET VCINSTALLDIR=%VSINSTALLDIR% rem rem Root of Visual Studio ide installed files. rem SET DevEnvDir=%VSINSTALLDIR% rem rem Root of Visual C++ installed files. rem SET MSVCDir=%VCINSTALLDIR%\VC SET PATH=%DevEnvDir%;%MSVCDir%\BIN;%VCINSTALLDIR%\Common7\Tools;%VCINSTALLDIR%Common7 \Tools\bin\prerelease;%VCINSTALLDIR%\Common7\Tools\bin;%FrameworkSDKDir%\bin;%FrameworkDir%\%FrameworkVersion%;%PATH%; SET INCLUDE=%MSVCDir%\ATLMFC\INCLUDE;%MSVCDir%\INCLUDE;%MSVCDir%\PlatformSDK\include\gl;%MSVCDir%\PlatformSDK\include;%FrameworkSDKDir%\include;%INCLUDE% SET LIB=%MSVCDir%\ATLMFC\LIB;%MSVCDir%\LIB;%MSVCDir%\PlatformSDK\lib;%FrameworkSDKDir%\lib;%LIB% GOTO end :Usage ECHO. VSINSTALLDIR variable is not set. ECHO. ECHO SYNTAX: %0 GOTO end :end Here the console output, what I not understand here and find very suspicious is that after the “IF %ERRORLEVEL%” Statement in the first script all will be put out regardless the echo is set to off… Executing: "C:\Programme\IBM\Rhapsody752\Share\etc\vs2005_make.bat" Simulation.mak build IF %ERRORLEVEL%==0 ( Mehr? set arch=x86 Mehr? ) ELSE ( Mehr? set arch=x64 Mehr? ) call "%ProgramFiles%\IBM\Rhapsody752\Share\etc\Vcvars_VisualStudio2005.bat" %arch% :: param 1 - Processor architecture @echo off ECHO param 1 = %1 param 1 = x86 IF %1==x86 ( Mehr? SET ProgrammPath=%ProgramFiles% Mehr? ) ELSE IF %1==x64 ( Mehr? SET ProgrammPath=%ProgramFiles(x86)% Mehr? ) ELSE ( Mehr? ECHO Unknowen architectur Mehr? EXIT /B 1 Mehr? ) SET VSINSTALLDIR="%ProgrammPath%\Microsoft Visual Studio 8\Common7\IDE" SET VCINSTALLDIR="%ProgrammPath%\Microsoft Visual Studio 8" SET FrameworkDir=C:\WINDOWS\Microsoft.NET\Framework SET FrameworkVersion=v2.0.50727 SET FrameworkSDKDir="%ProgrammPath%\Microsoft Visual Studio 8\SDK\v2.0" rem Root of Visual Studio common files. IF %VSINSTALLDIR%=="" GOTO Usage IF %VCINSTALLDIR%=="" SET VCINSTALLDIR=%VSINSTALLDIR% rem rem Root of Visual Studio ide installed files. rem SET DevEnvDir=%VSINSTALLDIR% rem rem Root of Visual C++ installed files. rem SET MSVCDir=%VCINSTALLDIR%\VC SET PATH=%DevEnvDir%;%MSVCDir%\BIN;%VCINSTALLDIR%\Common7\Tools;%VCINSTALLDIR%\Common7\Tools\bin\prerelease;%VCINSTALLDIR%\Common7\Tools\bin;%FrameworkSDKDir%\bin;%FrameworkDir%\%FrameworkVersion%;%PATH%; SET INCLUDE=%MSVCDir%\ATLMFC\INCLUDE;%MSVCDir%\INCLUDE;%MSVCDir%\PlatformSDK\include\gl;%MSVCDir%\PlatformSDK\include;%FrameworkSDKDir%\include;%INCLUDE% SET LIB=%MSVCDir%\ATLMFC\LIB;%MSVCDir%\LIB;%MSVCDir%\PlatformSDK\lib;%FrameworkSDKDir%\lib;%LIB% GOTO end Build Done I hope someone have an idea, i work now since two days and don't find the error... thanking you in anticipation. Note: The word “Mehr?” in the text output is german and means “more”. I don't know were it comes from and it is possible that it is a bad translation from the English output to german.

    Read the article

  • How can I tell which "explorer.exe" process is the main one?

    - by HodofHod
    I have a batch file that changes a few registry files, and then restarts explorer.exe so that they take effect. I'm using the command taskkill /f /im explorer.exe and then explorer.exe which of course kills all the explorer.exe processes, including the explorer windows I have open. Obviously, I am using the option to Launch folder windows in a separate process. Is there any way I can determine which instance of explorer.exe is the main one, and just kill that?

    Read the article

  • System.Data.SqlClient.SqlException: Must declare the scalar variable "@"

    - by Owala Wilson
    Haloo everyone...I am new to asp.net and I have been trying to query one table, and if the value returns true execute another query. here is my code: protected void Button1_Click(object sender, EventArgs e) { SqlConnection con = new SqlConnection(ConfigurationManager.ConnectionStrings["MyServer"].ConnectionString); SqlConnection con1 = new SqlConnection(ConfigurationManager.ConnectionStrings["MyServer"].ConnectionString); int amounts = Convert.ToInt32(InstallmentPaidBox.Text) + Convert.ToInt32(InterestPaid.Text) + Convert.ToInt32(PenaltyPaid.Text); int loans = Convert.ToInt32(PrincipalPaid.Text) + Convert.ToInt32(InterestPaid.Text); con.Open(); DateTime date = Convert.ToDateTime(DateOfProcessing.Text); int month1 = Convert.ToInt32(date.Month); int year1 = Convert.ToInt32(date.Year); SqlCommand a = new SqlCommand("Select Date,max(Amount)as Amount from Minimum_Amount group by Date",con); SqlDataReader sq = a.ExecuteReader(); while (sq.Read()) { DateTime date2 = Convert.ToDateTime(sq["Date"]); int month2 = Convert.ToInt32(date2.Month); int year2 = Convert.ToInt32(date2.Year); if (month1 == month2 && year1 == year2) { int amount = Convert.ToInt32(sq["Amount"]); string scrip = "<script>alert('Data Successfully Added')</script>"; Page.ClientScript.RegisterClientScriptBlock(this.GetType(), "Added", scrip); int areas = amount - Convert.ToInt32(InstallmentPaidBox.Text); int forwarded = Convert.ToInt32(BalanceBroughtTextBox.Text) + Convert.ToInt32(InstallmentPaidBox.Text); if (firsttime.Checked) { int balance = areas + Convert.ToInt32(PenaltyDue.Text) + Convert.ToInt32(InterestDue.Text); SqlCommand cmd = new SqlCommand("insert into Cash_Position(Member_No,Welfare_Amount, BFWD,Amount,Installment_Paid,Loan_Repayment,Principal_Payment,Interest_Paid,Interest_Due,Loan_Balance,Penalty_Paid,Penalty_Due,Installment_Arrears,CFWD,Balance_Due,Date_Prepared,Prepared_By) values(@a,@b,@c,@d,@e,@)f,@g,@h,@i,@j,@k,@l,@m,@n,@o,@p,@q", con); cmd.Parameters.Add("@a", SqlDbType.Int).Value = MemberNumberTextBox.Text; cmd.Parameters.Add("@b", SqlDbType.Int).Value = WelfareAmount.Text; cmd.Parameters.Add("@c", SqlDbType.Int).Value = BalanceBroughtTextBox.Text; cmd.Parameters.Add("@d", SqlDbType.Int).Value = amounts; cmd.Parameters.Add("@e", SqlDbType.Int).Value = InstallmentPaidBox.Text; cmd.Parameters.Add("@f", SqlDbType.Int).Value = loans; cmd.Parameters.Add("@g", SqlDbType.Int).Value = PrincipalPaid.Text; cmd.Parameters.Add("@h", SqlDbType.Int).Value = InterestDue.Text; cmd.Parameters.Add("@i", SqlDbType.Int).Value = InterestDue.Text; cmd.Parameters.Add("@j", SqlDbType.Int).Value = 0; cmd.Parameters.Add("@k", SqlDbType.Int).Value = PenaltyPaid.Text; cmd.Parameters.Add("@l", SqlDbType.Int).Value = PenaltyDue.Text; cmd.Parameters.Add("@m", SqlDbType.Int).Value = areas; cmd.Parameters.Add("@n", SqlDbType.Int).Value = forwarded; cmd.Parameters.Add("@o", SqlDbType.Int).Value = balance; cmd.Parameters.Add("@p", SqlDbType.Date).Value = date; cmd.Parameters.Add("@q", SqlDbType.Text).Value = PreparedBy.Text; int rows = cmd.ExecuteNonQuery(); con.Close();

    Read the article

  • Super slow opening my downloads folder

    - by Mark
    I have an exe file in my download folder that I half downloaded through utorrent (it's not piracy, a legit file from people who use bittorrent to distribute large files). I think I tried to open it while it was still sharing, that is, did not stop the upload. That actually froze my computer. When I restart in utorrent I set the file to be deleted. Unfortunately even though utorrent doesn't see that file anymore, it's still visible in my download folder. Whenever I try to open my download folder it literally takes 10 minutes or more. It opens, but is empty and the blue progress bar needs a long time to complete. After completion I can use the download folder normally, but opening and closing things in that folder takes a long time. I see the exe that I tried to download. I tried to delete it. But it was taking so long 30+ minutes that I eventually just hit cancel. That doesn't even work, and it was slowing down the computer. Couldn't figure out how to stop the delete so I just pulled the plug. Should I just forget about that dl folder and set a new one? Is there something I can do? Thanks.

    Read the article

  • Installing an exe with Powershell DSC Package resource gets return code 1619

    - by Jay Spang
    I'm trying to use Powershell DSC's Package resource to install an exe... Perforce's P4V to be specific. Here's my code: Configuration PerforceMachine { Node "SERVERNAME" { Package P4V { Ensure = "Present" Name = "Perforce Visual Components" Path = "\\nas\share\p4vinst64.exe" ProductId = '' Arguments = "/S /V/qn" # args for silent mode LogPath = "$env:ProgramData\p4v_install.log" } } } When running this, this is the error Powershell gives me: PowerShell provider MSFT_PackageResource failed to execute Set-TargetResource functionality with error message: The return code 1619 was not expected. Configuration is likely not correct + CategoryInfo : InvalidOperation: (:) [], CimException + FullyQualifiedErrorId : ProviderOperationExecutionFailure + PSComputerName : SERVERNAME According to documentation, return code 1619 means the MSI package couldn't be opened. However, when I manually log in to the machine and run "\\nas\share\p4vinst64.exe /S /V/qn", the install works flawlessly. Does anyone know why this is failing? Alternately, can anyone tell me how to troubleshoot this? I pasted all the error information I got from the terminal, my log file (p4v_install.log) is a 0 byte file, and there are no events in the event viewer. I don't know how to troubleshoot it any further! EDIT: I should note that I also tried using the File resource to copy the file locally, and then install it from there. Sadly, that met with the same result.

    Read the article

  • new ActiveXObject('Word.Application') creates new winword.exe process when IE security does not allo

    - by Mark Ott
    We are using MS Word as a spell checker for a few fields on a private company web site, and when IE security settings are correct it works well. (Zone for the site set to Trusted, and trusted zone modified to allow control to run without prompting.) The script we are using creates a word object and closes it afterward. While the object exists, a winword.exe process runs, but it is destroyed when the word object is closed. If our site is not set in the trusted zone (Internet zone with default security level) the call that creates the word object fails as expected, but the winword.exe process is still created. I do not have any way to interact with this process in the script, so the process stays around until the user logs off (users have no way to manually destroy the process, and it wouldn't be a good solution even if they did.) The call that attempts to create the object is... try { oWordApplication = new ActiveXObject('Word.Application'); } catch(error) { // irrelevant code removed, described in comments.. // notify user spell check cannot be used // disable spell check option } So every time the page is loaded this code may be run again, creating yet another orphan winword.exe process. oWordApplication is, of course, undefined in the catch block. I would like to be able to detect the browser security settings beforehand, but I have done some searching on this and do not think that it is possible. Management here is happy with it as it is. As long as IE security is set correctly it works, and it works well for our purposes. (We may eventually look at other options for spell check functionality, but this was quick, inexpensive, and does everything we need it to do.) This last problem bugs me and I'd like to do something about it, but I'm out of ideas and I have other things that are more in need of my attention. Before I put it aside, I thought I'd ask for suggestions here...

    Read the article

  • MSBuild on TeamCity Server can't find AL.exe

    - by Tim Long
    I'm having a problem on my TeamCity CI build server where during compilation I get the following error: C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets(2342, 9): error MSB3086: Task could not find "AL.exe" using the SdkToolsPath "" or the registry key "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Microsoft SDKs\Windows\v7.0A". Make sure the SdkToolsPath is set and the tool exists in the correct processor specific location under the SdkToolsPath and that the Microsoft Windows SDK is installed I've found similar reports from a year ago when people were upgrading to .NET 3.5, for example this one. In that case, installing the latest SDK solved the issue, however I have already installed the latest SDK (Microsoft Windows SDK for Windows 7 and .NET Framework 4) on my build server. The MSBuild tools are all there on the server, in a folder called C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319 and AL.exe exists in C:\Program Files\Microsoft SDKs\Windows\v7.1\Bin\NETFX 4.0 Tools However the registry key mentioned in the error message does not exist. So, it seems like there is something wrong with the installation/configuration of MSBuild. This error only happens for projects that have embedded resources, which require AL.exe. Please, anyone solved this issue or have any clues what's wrong?

    Read the article

  • Visual Studio Debugging is not attaching to WebDev.WebServer.EXE

    - by Aaron Daniels
    I have a solution with many projects. On Debug, I have three web projects that I want to start up on their own Cassini ASP.NET Web Development servers. In the Solution Properties - Common Properties - Startup Project, I have Multiple startup projects chosen with the three web applications' Action set to Start. All three web development servers start, and all three web pages load. However, Visual Studio is only attaching to two of the WebDev.WebServer.EXE processes. I have to manually go attach to the third process in order to debug it with the debugger. This behavior just started happening, and I'm at a loss as to how to troubleshoot this. Any help is appreciated. EDIT: Also to note, I have stopped and restarted the development servers several times with no change in behavior. Also, when attaching to the process manually, I see that the Type property of the two automatically attached WebDev.WebServer.EXE processes is Managed, while the Type property of the unattached WebDev.WebServer.EXE process is TSQL, Managed, x86. When looking at the project's properties, however, I am targeting AnyCPU, and do NOT have SQL Server debugging enabled. EDIT: Also to note, the two projects that attach correctly are C# web applications. <ProjectTypeGuids>{349c5851-65df-11da-9384-00065b846f21};{fae04ec0-301f-11d3-bf4b-00c04f79efbc}</ProjectTypeGuids> The project that is not attaching correctly is a VB.NET web application. <ProjectTypeGuids>{349c5851-65df-11da-9384-00065b846f21};{F184B08F-C81C-45F6-A57F-5ABD9991F28F}</ProjectTypeGuids> EDIT: Also to note, the behavior is the same on another workstation. So odds are that it's not a machine specific problem.

    Read the article

  • autoconf libtool library linker path incorrect (need drive-letter) for MinGW ld.exe in Cygwin

    - by Tam Toucan
    I use autoconf and when the target is mingw I was using the -mno-cygwin flag. This has been removed so I'm trying to using the mingw tool chain. The problem is the linker isn't finding my libraries /bin/sh ../../../libtool --tag=CXX --mode=link mingw32-g++ -g -Wall -pedantic -DNOMINMAX -D_REENTRANT -DWIN32 -I /usr/local/include/w32api -L/usr/local/lib/w32api -o testRandom.exe testRandom.o -L../../../lib/Random -lRandom libtool: link: mingw32-g++ -g -Wall -pedantic -DNOMINMAX -D_REENTRANT -DWIN32 -I /usr/local/include/w32api -o .libs/testRandom.exe testRandom.o -L/usr/local/lib/w32api -L/home/Tam/src/3DS_Games/lib/Random -lRandom D:\cygwin\opt\MinGW\bin\..\lib\gcc\mingw32\3.4.5\..\..\..\..\mingw32\bin\ld.exe: cannot find -lRandom To link this from the command line using the mingw linker the -L path needs the drive letter i.e mingw32-ld testRandom.o -LD:/home/Tam/src/3DS_Games/lib/Random -lRandom works. The -L path is generated from the makefile.am's which have LDADD = -L$(top_builddir)/lib/Random -lRandom However I can't find how to set top_builddir to a relative path or to start it with the drive letter (my autoconf skills are weak). As a tempoary "solution" I have removed the use of libtool. I could hack a $(DRIVE_LETTER) infront of every -L option, but I'd like to find something better.

    Read the article

  • ildasm and dynamic exe files

    - by TonyNeallon
    Hi There, I am trying to create an application can modify properties in IL to create a slightly different executable. E.g Client A runs app and a label on the WinForm label Reads "Client A:". Client B runs the app and Label Says "Client B". Easy I know using config files or resource files but thats not an option for this project. The Main program needs to be able to generate .exe file dynamically based on some form fields entered by user. My solution was to create a standalone executable that contained all the elements which I needed to make dynamic. I then used ildasm to generate the IL and thought that I could use this IL and substitute tags for the elements i wanted to make dynamic. I could then replace those tags at runtime after user filled the form using regex etc. The problem is, the if i re save the IL file generated by ILDASM as an exe and try to run it. I just launches console and does nothing. Am I going about this the wrong way? I didnt want to delve into Reflection as the dynamic .exe is a really simple one and I thought reverse engineering IL with ildasm would be the quickest way. You thoughts and pointers are much appreciated. Tony

    Read the article

  • How to properly force a Blackberry Java application to install using Loader.exe

    - by Kevin White
    I want to include the Application Loader process in a software installation, to ensure that users get our software installed on their Blackberry by the time our installer software finishes. I know this is possible, because Aerize Card Loader (http://aerize.com/blackberry/software/loader/) does this. When you install their software, if your Blackberry is connected the Application Loader will come up and force the .COD file to install to the device. I can't make it work. Looking at RIM's own documentation, I need to: Place the ALX and COD files into a subfolder here: C:\Program Files\Common Files\Research In Motion\Shared\Applications\ Add a path to the ALX file in HKCU\Software\Research In Motion\Blackberry\Loader\Packages Index the application, by executing this at the command line: loader.exe /index Start the force load, by doing this: loader.exe /defaultUSB /forceload When I execute that last command, the Application Loader comes up and says that all applications are up to date and nothing needs to be done. If I execute loader.exe by double-clicking on it (or typing in the command with no parameters), I get the regular Application Loader wizard. It shows my program as listed, but un-checked. If I check it and click next, it will install to the Blackberry. (This is the part that I want to avoid, and that Aerize Card Loader's install process avoids.) What am I missing? It appears that the Aerize installer is doing something different but I haven't been able to ascertain what.

    Read the article

  • Unable to launch onscreen keyboard (osk.exe) from a 32-bit process on Win7 x64

    - by Steven Robbins
    90% of the time I am unable to launch osk.exe from a 32bit process on Win7 x64. Originally the code was just using: Process.Launch("osk.exe"); Which won't work on x64 because of the directory virtualization. Not a problem I thought, I'll just disable virtualization, launch the app, and enable it again, which I thought was the correct way to do things. I also added some code to bring the keyboard back up if it has been minimized (which works fine) - the code (in a sample WPF app) now looks as follows: using System; using System.Collections.Generic; using System.Linq; using System.Text; using System.Windows; using System.Windows.Controls; using System.Windows.Data; using System.Windows.Documents; using System.Windows.Input; using System.Windows.Media; using System.Windows.Media.Imaging; using System.Windows.Navigation;using System.Diagnostics; using System.Runtime.InteropServices; namespace KeyboardTest { /// <summary> /// Interaction logic for MainWindow.xaml /// </summary> public partial class MainWindow : Window { [DllImport("kernel32.dll", SetLastError = true)] private static extern bool Wow64DisableWow64FsRedirection(ref IntPtr ptr); [DllImport("kernel32.dll", SetLastError = true)] public static extern bool Wow64RevertWow64FsRedirection(IntPtr ptr); private const UInt32 WM_SYSCOMMAND = 0x112; private const UInt32 SC_RESTORE = 0xf120; [DllImport("user32.dll", CharSet = CharSet.Auto)] static extern IntPtr SendMessage(IntPtr hWnd, UInt32 Msg, IntPtr wParam, IntPtr lParam); private string OnScreenKeyboadApplication = "osk.exe"; public MainWindow() { InitializeComponent(); } private void KeyboardButton_Click(object sender, RoutedEventArgs e) { // Get the name of the On screen keyboard string processName = System.IO.Path.GetFileNameWithoutExtension(OnScreenKeyboadApplication); // Check whether the application is not running var query = from process in Process.GetProcesses() where process.ProcessName == processName select process; var keyboardProcess = query.FirstOrDefault(); // launch it if it doesn't exist if (keyboardProcess == null) { IntPtr ptr = new IntPtr(); ; bool sucessfullyDisabledWow64Redirect = false; // Disable x64 directory virtualization if we're on x64, // otherwise keyboard launch will fail. if (System.Environment.Is64BitOperatingSystem) { sucessfullyDisabledWow64Redirect = Wow64DisableWow64FsRedirection(ref ptr); } // osk.exe is in windows/system folder. So we can directky call it without path using (Process osk = new Process()) { osk.StartInfo.FileName = OnScreenKeyboadApplication; osk.Start(); osk.WaitForInputIdle(2000); } // Re-enable directory virtualisation if it was disabled. if (System.Environment.Is64BitOperatingSystem) if (sucessfullyDisabledWow64Redirect) Wow64RevertWow64FsRedirection(ptr); } else { // Bring keyboard to the front if it's already running var windowHandle = keyboardProcess.MainWindowHandle; SendMessage(windowHandle, WM_SYSCOMMAND, new IntPtr(SC_RESTORE), new IntPtr(0)); } } } } But this code, most of the time, throws the following exception on osk.Start(): The specified procedure could not be found at System.Diagnostics.Process.StartWithShellExecuteEx(ProcessStartInfo startInfo) I've tried putting long Thread.Sleep commands in around the osk.Start line, just to make sure it wasn't a race condition, but the same problem persists. Can anyone spot where I'm doing something wrong, or provide an alternative solution for this? It seems to work fine launching Notepad, it just won't play ball with the onscreen keyboard.

    Read the article

  • .NET datetime issue with SQL stored procedure

    - by DanO
    I am getting the below error when executing my application on a Windows XP machine with .NET 2.0 installed. On my computer Windows 7 .NET 2.0 - 3.5 I am not having any issues. The target SQL server version is 2005. This error started occurring when I added the datetime to the stored procedure. I have been reading alot about using .NET datetime with SQL datetime and I still have not figured this out. If someone can point me in the right direction I would appreciate it. Here is the where I believe the error is coming from. private static void InsertRecon(string computerName, int EncryptState, TimeSpan FindTime, Int64 EncryptSize, DateTime timeWritten) { SqlConnection DBC = new SqlConnection("server=server;UID=InventoryServer;Password=pass;database=Inventory;connection timeout=30"); SqlCommand CMD = new SqlCommand(); try { CMD.Connection = DBC; CMD.CommandType = CommandType.StoredProcedure; CMD.CommandText = "InsertReconData"; CMD.Parameters.Add("@CNAME", SqlDbType.NVarChar); CMD.Parameters.Add("@ENCRYPTEXIST", SqlDbType.Int); CMD.Parameters.Add("@RUNTIME", SqlDbType.Time); CMD.Parameters.Add("@ENCRYPTSIZE", SqlDbType.BigInt); CMD.Parameters.Add("@TIMEWRITTEN", SqlDbType.DateTime); CMD.Parameters["@CNAME"].Value = computerName; CMD.Parameters["@ENCRYPTEXIST"].Value = EncryptState; CMD.Parameters["@RUNTIME"].Value = FindTime; CMD.Parameters["@ENCRYPTSIZE"].Value = EncryptSize; CMD.Parameters["@TIMEWRITTEN"].Value = timeWritten; DBC.Open(); CMD.ExecuteNonQuery(); } catch (System.Data.SqlClient.SqlException e) { PostMessage(e.Message); } finally { DBC.Close(); CMD.Dispose(); DBC.Dispose(); } } Unhandled Exception: System.ArgumentOutOfRangeException: The SqlDbType enumeration value, 32, is invalid. Parameter name: SqlDbType at System.Data.SqlClient.MetaType.GetMetaTypeFromSqlDbType(SqlDbType target) at System.Data.SqlClient.SqlParameter.set_SqlDbType(SqlDbType value) at System.Data.SqlClient.SqlParameter..ctor(String parameterName, SqlDbType dbType) at System.Data.SqlClient.SqlParameterCollection.Add(String parameterName, SqlDbType sqlDbType) at ReconHelper.getFilesInfo.InsertRecon(String computerName, Int32 EncryptState, TimeSpan FindTime, Int64 EncryptSize, DateTime timeWritten) at ReconHelper.getFilesInfo.Main(String[] args)

    Read the article

  • output parameter into label

    - by MyHeadHurts
    instead of returning my output paremeter value in my stored procedure to my label it returns the default value i set my output parameter to. why cant i put my output parameter into my text label Dim reader As SqlDataReader cmd.Parameters.AddWithValue("@tour", "2365") cmd.Parameters.Add("@tourname", SqlDbType.VarChar) cmd.Parameters("@tourname").Direction = ParameterDirection.Output cmd.CommandText = "test" cmd.CommandType = CommandType.StoredProcedure cmd.Connection = conn conn.Open() reader = cmd.ExecuteReader() Dim myTable As DataTable = New DataTable() myTable.Load(reader) DropDownList1.DataSource = myTable DropDownList1.DataTextField = "ddate7" DropDownList1.DataBind() Label1.Text = cmd.Parameters("@tourname").ToString conn.Close()

    Read the article

  • Running exe built in VC++ on XP and WIN7

    - by rajivpradeep
    sprintf_s(cmd, "%c:\index.exe", driver); STARTUPINFOA si; PROCESS_INFORMATION pi; ::SecureZeroMemory(&si, sizeof(STARTUPINFO)); ::SecureZeroMemory(&pi, sizeof(PROCESS_INFORMATION)); si.dwFlags = STARTF_USESHOWWINDOW | STARTF_USESTDHANDLES; si.wShowWindow = SW_SHOW; RES = ::CreateProcessA(NULL, cmd, NULL, NULL, NULL, NULL, NULL, NULL, &si, &pi); DWORD exitcode; DWORD err; do { Sleep(100); GetExitCodeProcess(pi.hProcess, &exitcode); } while (exitcode !=0); GetExitCodeThread(pi.hThread, &exitcode); RES = TerminateThread(pi.hThread, exitcode); if (RES == 0) err = GetLastError(); I am trying to run a flash file, the application is built in VS 2008 , on win 7. The application works well on WIN7 but fails in XP. Ie the application launches but doesn't complete the task. I see the application running in Task Manager

    Read the article

  • File association and msconfig broken. Malware?

    - by Moshe
    A friend of mine had an Acer laptop. It has Vista Home Basic. I can't get system properties open. Msconfig does not run. Also, exe filetype is asking me what program to run it with. How can I fix that? I'm running AVG now. Assuming nothing shows up, what are fixes to the above mentioned issues?

    Read the article

  • rundll32 gets stuck when running games on windows 7 [closed]

    - by Midhat
    When I run a game on my windows 7 laptop, Rundll32 completely uses up one of my cores and the game wont start. By searching the web I have been able to fix it by 1 - Disabling game info collection/updation from the games explorer. It solved the problem for some games but not all 2 - Killing the game exe once rundll32 gets stuck and restarting the game This has solved the problem for now, but is there a proper and permanent solution to this?

    Read the article

  • CefSharp.BrowserSubprocess.exe has stopped working

    - by Amogh
    I have CefSharp-master project with which is Built on Chromium- 31.0.1650.57. All is working fine and perfect, but when I click on link to load/view PDF file on an website and popup get loaded and after some time I got dialog box saying "CefSharp.BrowserSubprocess.exe has stopped working." and oped popup window become black. Below is what I found in windows event viewer.. Application: CefSharp.BrowserSubprocess.exe Framework Version: v4.0.30319 Description: The process was terminated due to an unhandled exception. Exception Info: System.AccessViolationException Stack: at <Module>.CefExecuteProcess(CefMainArgs*, CefRefPtr<CefApp>*) at CefSharp.CefAppWrapper.Run(System.String[]) at CefSharp.BrowserSubprocess.Program.Main(System.String[]) What is problem? I searched a lot but didn't find any think.

    Read the article

< Previous Page | 25 26 27 28 29 30 31 32 33 34 35 36  | Next Page >