Search Results

Search found 58355 results on 2335 pages for 'customize windows 7'.

Page 293/2335 | < Previous Page | 289 290 291 292 293 294 295 296 297 298 299 300  | Next Page >

  • WPF ToolBar: how to customize appearance (remove dots and a pointer)

    - by Nike
    I use ToolBar for my WPF application. As I understand, there is no easy way to make it floating. I just want to remove elements which I don't want to be displayed: several dots in the left side, and a pointer (arrow) in right side of ToolBar. Is there any Properties to customize view of ToolBar? Or, maybe, it's possible to redefine a ToolBar Template?

    Read the article

  • Windows Vista/Win7 Privilege Problem: SeDebugPrivilege & OpenProcess

    - by KevenK
    Everything I've been able to find about escalating to the appropriate privileges for my needs has agreed with my current methods, but the problem exists. I'm hoping maybe someone has some Windows Vista/Win7 internals experience that might shine some light where there is only darkness. I'm sure this will get long, but please bare with me. Context: I'm working on an app that requires accessing the memory of other processes on the current machine. This, obviously, requires administrator rights. It also requires SeDebugPrivilege, which I believe myself to be acquiring correctly, although I question if more privileges aren't necessary and thus the cause of my problems. Code has so far worked successfully on all versions of Windows XP, and on my test Vista32 and Win7x64 environments. Process: Program will Always be run with Administrator Rights. This can be assumed throughout this post. Escalating the current process's Access Token to include SeDebugPrivilege rights. Using EnumProcesses to create a list of current PIDs on the system Opening a handle using OpenProcess with PROCESS_ALL_ACCESS access rights Using ReadProcessMemory to read the memory of the other process. Problem: Everything has been working fine during development and my personal testing (including Windows XP 32 & 64, Windows Vista 32, and Windows 7 x64). However, during a test deployment onto both Windows Vista(32-bit) and Windows 7(64-bit) machines of a colleague, there seems to be a privilege/rights problem with OpenProcess failing with a generic Access Denied error. This occurs both when running as a limited User (as would be expected) and also when run explicitly as Administrator (Right-click Run as Administrator and when run from an Administrator level command prompt). However, this problem has been unreproducible for myself in my test environment. I have witnessed the problem first hand, so I trust that the problem exists. The only difference that I can discern between the actual environment and my test environment is that the actual error is occurring when using a Domain Administrator account at the UAC prompt, whereas my tests (which work with no errors) use a local administrator account at the UAC prompt. It appears that although the credentials being used allow UAC to 'run as administrator', the process is still not obtaining the correct rights to be able to OpenProcess on another process. I am not familiar enough with the internals of Vista/Win7 to know what this might be, and I am hoping someone has an idea of what could be the cause. The Kicker: The person who has reported this error, and who's environment can regularly reproduce this bug, has a small application named along the lines of RunWithDebugEnabled which is a small bootstrap program which appears to escalate its own privileges and then launch the executable passed to it (thus inheriting the escalated privileges). When run with this program, using the same Domain Administrator credentials at UAC prompt, the program works correctly and is able to successfully call OpenProcess and operates as intended. So this is definitely a problem with acquiring the correct privileges, and it is known that the Domain Administrator account is an administrator account that should be able to access the correct rights. (Obviously obtaining this source code would be great, but I wouldn't be here if that were possible). Notes: As noted, the errors reported by the failed OpenProcess attempts are Access Denied. According to MSDN documentation of OpenProcess: If the caller has enabled the SeDebugPrivilege privilege, the requested access is granted regardless of the contents of the security descriptor. This leads me to believe that perhaps there is a problem under these conditions either with (1) Obtaining SeDebugPrivileges or (2) Requiring other privileges which have not been mentioned in any MSDN documentation, and which might differ between a Domain Administrator account and a Local Administrator account Sample Code: void sample() { ///////////////////////////////////////////////////////// // Note: Enabling SeDebugPrivilege adapted from sample // MSDN @ http://msdn.microsoft.com/en-us/library/aa446619%28VS.85%29.aspx // Enable SeDebugPrivilege HANDLE hToken = NULL; TOKEN_PRIVILEGES tokenPriv; LUID luidDebug; if(OpenProcessToken(GetCurrentProcess(), TOKEN_ADJUST_PRIVILEGES, &hToken) != FALSE) { if(LookupPrivilegeValue(NULL, SE_DEBUG_NAME, &luidDebug) != FALSE) { tokenPriv.PrivilegeCount = 1; tokenPriv.Privileges[0].Luid = luidDebug; tokenPriv.Privileges[0].Attributes = SE_PRIVILEGE_ENABLED; if(AdjustTokenPrivileges(hToken, FALSE, &tokenPriv, 0, NULL, NULL) != FALSE) { // Always successful, even in the cases which lead to OpenProcess failure cout << "SUCCESSFULLY CHANGED TOKEN PRIVILEGES" << endl; } else { cout << "FAILED TO CHANGE TOKEN PRIVILEGES, CODE: " << GetLastError() << endl; } } } CloseHandle(hToken); // Enable SeDebugPrivilege ///////////////////////////////////////////////////////// vector<DWORD> pidList = getPIDs(); // Method that simply enumerates all current process IDs ///////////////////////////////////////////////////////// // Attempt to open processes for(int i = 0; i < pidList.size(); ++i) { HANDLE hProcess = NULL; hProcess = OpenProcess(PROCESS_ALL_ACCESS, FALSE, pidList[i]); if(hProcess == NULL) { // Error is occurring here under the given conditions cout << "Error opening process PID(" << pidList[i] << "): " << GetLastError() << endl; } CloseHandle(hProcess); } // Attempt to open processes ///////////////////////////////////////////////////////// } Thanks! If anyone has some insight into what possible permissions/privileges/rights/etc that I may be missing to correctly open another process (Assuming the executable has been properly "Run as Administrator"ed) on Windows Vista and Windows 7 under the above conditions, it would be most greatly appreciated. I wouldn't be here if I weren't absolutely stumped, but I'm hopeful that once again the experience and knowledge of the group shines bright. I thank you for taking the time to read this wall of text. The good intentions alone are appreciated, thanks for being the type of person that makes SO so useful to all!

    Read the article

  • Silverlight - Bing Maps - Customize Pushpin Style

    - by user70192
    Hello, How do I customize the style of a pushpin on the Bing Maps Silverlight control? I have reviewed the documentation shown here (http://www.microsoft.com/maps/isdk/silverlightbeta/#MapControlInteractiveSdk.Tutorials.TutorialCustomPushpin). However, I am programmatically adding a variable number of Pushpins. Ideally, I would like to be able to set the style of each pushin, but I do not know how. Can someone show me how? Thank you!

    Read the article

  • Cannot get NLogViewer to receive msgs from local machine

    - by slolife
    I cannot get NLogViewer to receive msgs from local machine. My machine is Windows 7. I am able to get a remote machine to send NLog messages to my local box and NLogViewer on my local box shows the message fine. But, if I run an app locally, and config NLog to spit messages to my local box, NLogViewer doesn't get the messages. Here's my config: <targets> <target name="viewer" xsi:type="NLogViewer" address="udp://localhost:4050"/> </targets> <rules> <logger name="*" minlevel="Info" writeTo="viewer" /> <rules> Is it Windows 7 security? I have config'd Windows Firewall to allow UDP port 4050 inbound and outbound. My apps are an ASP.NET site and a few windows services.

    Read the article

  • List of Microsoft training kits (2012)

    - by DigiMortal
    Some years ago I published list of Microsoft training kits for developers. Now it’s time to make a little refresh and list current training kits available. Feel free to refer additional training kits in comments. Sharepoint 2010 Developer Training Kit SharePoint 2010 and Windows Phone 7 Training Kit SharePoint and Windows Azure Development Kit Visual Studio 2010 and .NET Framework 4 Training Kit (December 2011) SQL Server 2012 Developer Training Kit SQL Server 2008 R2 Update for Developers Training Kit (May 2011 Update) SharePoint and Silverlight Training Kit Windows Phone 7 Training Kit for Developers - RTM Refresh Windows Phone 7.5 Training Kit Silverlight 4 Training Web Camps Training Kit Identity Developer Training Kit Internet Explorer 10 Training Kit Visual Studio LightSwitch Training Kit Office 2010 Developer Training Kit - June 2011 Office 365 Developer Training Kit - June 2011 Update Dynamics CRM 2011 Developer Training Kit PHP on Windows and SQL Server Training Kit (March 2011 Update) Windows Server AppFabric Training Kit Windows Server 2008 R2 Developer Training Kit - July 2009

    Read the article

  • Norton Ghost EBAB03F1: The specified network name is no longer available

    - by Breck Carter
    After about 15 minutes, a Norton Ghost 14 backup fails with Error EBAB03F1: The specified network name is no longer available. The source computer is a P4 laptop running Windows XP SP3. The target computer is a Core2 Quad desktop running Windows Vista Ultimate 64bit. It does not help to disable Norton 360 on the source computer or Norton Antivirus 2008 on the target computer. The Event Viewer consistently shows the same two VSS-related errors after Norton Ghost starts but before it fails. It makes no difference if the VSS service is started or stopped. The VSS errors do not appear elsewhere in the event log, only after Ghost starts. The MSS event messages, however, are quite common, appearing throughout the log, and they may have nothing to do with the problem. Here is the Norton Ghost error display... -Errors exist. --Unable to write to file. ---Error EBAB03F1: The specified network name is no longer available. ---Unable to set file size. ----Error EBAB03F1: The specified network name is no longer available. ----Unable to write to file. -----Error EBAB03F1: The specified network name is no longer available. -----Unable to set file size. ------Error EBAB03F1: The specified network name is no longer available. Here are the source computer events, with the final error at the top and the "Ghost Starting" message at the bottom: ===== Event Type: Error Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:40:26 AM User: N/A Computer: PAVILION2 Description: Error EC8F17B7: Cannot create recovery points for job: Drive Backup of (C:\) (3). Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Details: 0xEBAB0005 Source: Norton Ghost ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 3421 Date: 11/09/2009 Time: 9:34:06 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Recovery completed for database ReportServer$SQLEXPRESSTempDB (database ID 6) in 1 second(s) (analysis 205 ms, redo 0 ms, undo 376 ms.) This is an informational message only. No user action is required. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 5d 0d 00 00 0a 00 00 00 ]....... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 17137 Date: 11/09/2009 Time: 9:34:02 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Starting up database 'ReportServer$SQLEXPRESSTempDB'. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: f1 42 00 00 0a 00 00 00 ñB...... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 12302 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: An internal inconsistency was detected in trying to contact shadow copy service writers. Please check to see that the Event Service and Volume Shadow Copy Service are operating properly. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 42 55 45 43 58 4d 4c 43 BUECXMLC 0008: 33 36 33 37 00 00 00 00 3637.... 0010: 42 55 45 43 58 4d 4c 43 BUECXMLC 0018: 33 36 30 37 00 00 00 00 3607.... ===== Event Type: Information Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:27:57 AM User: N/A Computer: PAVILION2 Description: Info 6C8F1F63: The drive-based backup job, Drive Backup of (C:\) (3), has been started manually. Details: Source: Norton Ghost

    Read the article

  • installshield: Windir returns c:\documents & settings\fcuser\windows instead of c:\windows

    - by Sakhawat Ali
    we have a setup developed in installshield vr 6.3. it is a self extractable single setup. it work fine in most on most of the Windows version but on Windows server 2003 64bit in Execution mode when doing RD it return user windows directory against WINDIR i.e. c:\documents & settings\fcuser\windows instead of C:\Windows. According to http://support.microsoft.com/?kbid=186499 it should work fine when i change the compatibility bit of Setup but it didn't. i tried changing compatibility bit of these key too (INSTRUN, SETUP and SETUP1 ) but it didn't work either. but when i when i run the setup within the self extractable by extracting it work fine.

    Read the article

  • How to customize an installer's UI

    - by Kapil
    I am building an installer for my windows app and have done this through a setup/installer project in visual studio. I was wondering how to customize he UI of the finish dialog box? I want to add a couple of check-boxes and launch an app after the user closes the finish box. Is there a way to do this in Visual studio itself or does it require any other tools? If other tools are required then are any of them free? Thanks Kapil

    Read the article

  • Does a Windows 7 dvd only have one language?

    - by user326639
    I'm a Dutch developer living in Spain. I recently composed a new computer from new parts and I installed Windows 7 Professional 64 bit (OEM) on it. On the web site of the on-line shop there was a note saying "language: Spanish". Because my English is quite a bit better than my Spanish, but mainly because it is much easier to find information on the web in English, I want my OS to be in English. I asked the on-line shop if they also sold the UK version of Windows 7 but they assured me that "all Windows 7 versions are multi-language". With the installation of XP a few years ago, I remember that I was offered the option English or Spanish while the installation process was still in the DOS-like (non-graphical) screen. While installing Windows 7, I did not see any non-graphical screen and the first time I was asked about the language, was in a drop-down list that contained only Spanish. I know about the language pack possibility of Windows 7, but this is not available on Professional. Even if I had Ultimate, I don't know if it would be possible to install Windows in Spanish, and then add English as a second language from a language pack. I get the impression that English has to be the base-language. Furthermore, I am a bit sceptical until I'd see it in action. What happens with shortcuts (i.e. Select All: ctrl-a in English / ctrl-e in Spanish, and what about logging messages in Event Viewer, etc) So can anybody tell me how it works with languages in Windows 7? Have I been misinformed by the computer shop? Could it be that OEM versions of Windows are single language an a full installation is not?

    Read the article

  • Is windows a "second class citizen" in the django community?

    - by Daniel Upton
    I'm currently doing R&D for a web application which we plan to host ourselves initially and then allow customers to self host. My task has been evaluating web frameworks to see which would give us the biggest productivity initially and ease of maintence while also allowing us to easily support deployment to customer controlled environments. Our team has experience with ASP.NET (MVC and Webforms) and Ruby on Rails. Our experience with rails is that windows deployment is a very taboo subject and any questions on IRC or SO are met with knee jerk "why not linux" responses.. However in this case our target market may be running windows or linux servers. Is this also the case in django land? Is it possible with rubbish performance? Is it possible with lost of pain? Is it seen as reasonable and not treated as a completely stupid idea for not wanting to run linux?

    Read the article

  • Launch a real install of Ubuntu already on another hard-drive in Windows 7 like a VM

    - by Chad M
    I'm not too familiar with VMs and the like so this may not even be possible. Here is what I have: A real, full install of Windows 7 on hard drive A. A real, full install of Ubuntu 10.04 on hard drive B. Grub allowing me to select what I want to launch when I start up my computer. It would be Amazing if I could do one of two things. Within Windows 7, launch my real install of ubuntu as if it were a VM. That means i would get all the installed software, all of the files, and all of the settings. Launch a VM copy of ubuntu 10.04 but some how make it use all of the installed software and settings from my real copy. Thanks!

    Read the article

  • How does Blizzard manage to support Mac OS and Windows in their games?

    - by begray
    I've always thought, that using Direct X for Windows was the most powerful, easy and modern method to create games with modern graphics nowdays. And knowing, that it's only Windows I thinks it's pretty difficult to make something similar on other platforms (Mac OS to be exact). But Blizzard somehow managed to deliver Starcraft 2 for Mac OS, and Diablo 3 will be available for Mac too. So what I'm interested in is information about: what technologies are they using for their game engines? are they using one engine for both games (Starcraft 2 and Diablo 3)? Or develop custom for each game? what are they paying in terms of time and money for Mac OS support? Thanks

    Read the article

  • Using Windows Previous Versions to access ZFS Snapshots (July 14, 2009)

    - by user12612012
    The Previous Versions tab on the Windows desktop provides a straightforward, intuitive way for users to view or recover files from ZFS snapshots.  ZFS snapshots are read-only, point-in-time instances of a ZFS dataset, based on the same copy-on-write transactional model used throughout ZFS.  ZFS snapshots can be used to recover deleted files or previous versions of files and they are space efficient because unchanged data is shared between the file system and its snapshots.  Snapshots are available locally via the .zfs/snapshot directory and remotely via Previous Versions on the Windows desktop. Shadow Copies for Shared Folders was introduced with Windows Server 2003 but subsequently renamed to Previous Versions with the release of Windows Vista and Windows Server 2008.  Windows shadow copies, or snapshots, are based on the Volume Snapshot Service (VSS) and, as the [Shared Folders part of the] name implies, are accessible to clients via SMB shares, which is good news when using the Solaris CIFS Service.  And the nice thing is that no additional configuration is required - it "just works". On Windows clients, snapshots are accessible via the Previous Versions tab in Windows Explorer using the Shadow Copy client, which is available by default on Windows XP SP2 and later.  For Windows 2000 and pre-SP2 Windows XP, the client software is available for download from Microsoft: Shadow Copies for Shared Folders Client. Assuming that we already have a shared ZFS dataset, we can create ZFS snapshots and view them from a Windows client. zfs snapshot tank/home/administrator@snap101zfs snapshot tank/home/administrator@snap102 To view the snapshots on Windows, map the dataset on the client then right click on a folder or file and select Previous Versions.  Note that Windows will only display previous versions of objects that differ from the originals.  So you may have to modify files after creating a snapshot in order to see previous versions of those files. The screenshot above shows various snapshots in the Previous Versions window, created at different times.  On the left panel, the .zfs folder is visible, illustrating that this is a ZFS share.  The .zfs setting can be toggled as desired, it makes no difference when using previous versions.  To make the .zfs folder visible: zfs set snapdir=visible tank/home/administrator To hide the .zfs folder: zfs set snapdir=hidden tank/home/administrator The following screenshot shows the Previous Versions panel when a file has been selected.  In this case the user is prompted to view, copy or restore the file from one of the available snapshots. As can be seen from the screenshots above, the Previous Versions window doesn't display snapshot names: snapshots are listed by snapshot creation time, sorted in time order from most recent to oldest.  There's nothing we can do about this, it's the way that the interface works.  Perhaps one point of note, to avoid confusion, is that the ZFS snapshot creation time isnot the same as the root directory creation timestamp. In ZFS, all object attributes in the original dataset are preserved when a snapshot is taken, including the creation time of the root directory.  Thus the root directory creation timestamp is the time that the directory was created in the original dataset. # ls -d% all /home/administrator         timestamp: atime         Mar 19 15:40:23 2009         timestamp: ctime         Mar 19 15:40:58 2009         timestamp: mtime         Mar 19 15:40:58 2009         timestamp: crtime         Mar 19 15:18:34 2009 # ls -d% all /home/administrator/.zfs/snapshot/snap101         timestamp: atime         Mar 19 15:40:23 2009         timestamp: ctime         Mar 19 15:40:58 2009         timestamp: mtime         Mar 19 15:40:58 2009         timestamp: crtime         Mar 19 15:18:34 2009 The snapshot creation time can be obtained using the zfs command as shown below. # zfs get all tank/home/administrator@snap101NAME                             PROPERTY  VALUEtank/home/administrator@snap101  type      snapshottank/home/administrator@snap101  creation  Mon Mar 23 18:21 2009 In this example, the dataset was created on March 19th and the snapshot was created on March 23rd. In conclusion, Shadow Copies for Shared Folders provides a straightforward way for users to view or recover files from ZFS snapshots.  The Windows desktop provides an easy to use, intuitive GUI and no configuration is required to use or access previous versions of files or folders. REFERENCES FOR MORE INFORMATION ZFS ZFS Learning Center Introduction to Shadow Copies of Shared Folders Shadow Copies for Shared Folders Client

    Read the article

  • Is it possible to boot Windows 7 from when you're harddrive's partition with two OSes?

    - by Muhammad
    I have a PC with a hard drive that's partition into home directories for Windows 7 and Ubuntu. I primarily use Windows 7 and occasionally (once a week) use Ubuntu. When I boot up my computer, I usually get taken to a boot menu that includes about 5 different options: 3 are for Ubuntu's configurations, one's for swap, and the forth is for Windows 7. Then after I select Windows 7 or Ubuntu from this menu, I get taken to another menu that again asks me for Windows 7 or Ubuntu. This time, there's only 2 options, Windows 7 and Ubuntu. [Side note: out of experience I realized most boot menus are timed and so are these.] So if I ever turn my computer on without actually sitting in front of it for a few minutes, it boots into Ubuntu. I'm trying to figure out what I need to do so I can first get rid of the 2 boot menus. And if possible, I'm looking for help changing my boot options where I can load up Windows 7 (even with the boot menu wait of about 30 seconds). My harddrive's partition's laid out like this: Windows 7 (C partition) Multimedia (D partition, I just use this for backup/non-OS stuff) Ubuntu (home directory) Swap Is there any other information I need to provide?

    Read the article

  • useful customize/enhanced php functions that make thing easy and better

    - by I Like PHP
    Hello All, i like to work in php bcoz it's just amazing language. please share basic, useful, enhanced and customize function that make things better and easy in php and must be used in our all PHP project, i m sharing some of them please share your customize function that may be useful for everyone alternative/ enhanced print_r() and var_dump() function watch( $what ) { echo '<pre>'; if ( is_array( $what ) ) { print_r ( $what ); } else { var_dump ( $what ); } echo '</pre>'; } usage: 1. watch($_POST); // to see all post variable 2. watch($array); // to see any variable may b array, string or a variable enhanced mysql_escape_string() for multidimensional array to prevent sql injection function recursive_escape(&$value) { if (is_array($value)) array_map('recursive_escape', $value); else $value = mysql_escape_string($value); } usage array_map('recursive_escape', $_POST); ---------------------For encoding Get variables-------------------------------------- function nkode($k) { if ( is_array( $k ) ) return array_map("base64_encode",$k); else return base64_encode($k); } ---------------------for decoding varaibles from GET--------------------------------- function dkode($k) { if ( is_array( $k ) ) return array_map("base64_decode",$k); else return base64_decode($k); } Usage <a href="somelink.php?pid=<?php echo nkode($someid)?>"> and on next page(somelink.php) $findID=dkode($_GET[pid]); date convert to mm/dd/yyyy to yyyy-mm-dd( if we use date datatype in mysql) and also change into mm/dd/yyyy to disply on page function dateconvert($date,$func) { if ($func == 1){ //insert conversion list($month, $day, $year) = split('[/.-]', $date); $date = "$year-$month-$day"; return $date; } if ($func == 2){ //output conversion list($year, $month, $day) = split('[-.]', $date); $date = "$month/$day/$year"; return $date; } } usage $firstDate=dateconvert($_POST['firstdate'],1); // for insertion in database $showDate=dateconvert($fetch->date_field,2) // to display on browser to clean(sql injection proof) data before doing some action with that variable function cleandata($data) { $success=0; $data=trim($data); $data=strtolower($data); $data=strip_tags($data); return $data; } usage cleandata($_POST[username]); cleandata($_GET[pid]); please share any basic function that must be used , Thanks

    Read the article

  • How can I display additional boot and shutdown information on the Windows 7 welcome screen?

    - by Daniel Saner
    There is a small tweak, I believe it is a registry key, that allows to display additional information on the Welcome and Shutting down screens of Windows 7 (and most likely Vista, too). I have activated this tweak on one of my systems; unfortunately I forgot how I did it, and I can't seem to find the website that originally gave me that information. Usually, the Windows 7 welcome screen will just display "Welcome" when logging in. With the tweak activated, my Welcome screen gives status information such as "Loading user settings" or "Preparing desktop". When shutting down, the default screen simply says "Shutting down". With the tweak activated, it gives additional status information such as "Stopping Windows services". This appears the same way that Windows gives information when updates are installed or configured during the startup or shutdown procedure, and I find them quite helpful in getting a feel for what task takes how long during that process. The only setting I was able to find is the Boot log checkbox on the Boot tab of the msconfig application. However, this results in Windows displaying console logs of drivers it is loading, etc., instead of the animated Windows title. This is NOT the setting I am looking for. The "additional boot information" setting that I have activated on this system still displays the regular animated Windows logo, and only replaces the strings displayed on the blue Welcome and Shutdown screens. Could someone direct me to the registry key (or whatever setting) that is used to get this behaviour? Edit: Here are a few pictures of the enhanced Welcome and Shutdown screens taken with my mobile phone—they're in German though. Login screens "Waiting for User Profile Service" and "Preparing desktop": Logout screen "Stopping Windows services":

    Read the article

  • Customize iPhone view for iPad

    - by Erick Sasse
    I have converted a very simple iPhone app to Universal app. Now I need to customize the view on the iPad to use a higher resolution image for the background, move and resize some labels, etc. How can I do it without changing the iPhone version? I can see that there is a new MainWindow-iPad.xib, but when I open in IB, it looks empty. Thanks.

    Read the article

  • Will a Wubi install of Ubuntu effect my Windows installation in anyway? [closed]

    - by Oddysee
    Possible Duplicate: What are the benefits of a disk install vs. Wubi? And can I migrate my settings easily? Having never tried a Linux OS before, I want to dabble and take a look at one. Ubuntu seems like a good distro to go with (due to how popular it is) and I want to use Wubi to try it out. I just wanted to know if anything I do while trying out Ubuntu will effect my Windows Installation or the files pertaining to it in anyway? If so, is it potentially Windows breaking?

    Read the article

  • Coding a web browser on Windows using a layout engine?

    - by samual johnson
    I've never attempted anything like this before but what I want to do is code a browser for Windows. I know that I can use the web-browser control that Microsoft has released, but I'm interested in seeing how the problem is solved from a lower level. So I want to know what layout engine I should be looking at? Or is a layout engine the best way to go? I've been looking at WebKit, but it seems rather Mac-centric, so I'm wondering if there are any more practical one's for windows? Has Microsoft released the source code for their webbrowser winforms control in the .Net framework? That would be dependent on the CLR anyway, I suppose? Any suggestions?

    Read the article

  • How to get Synergy working on Ubuntu 11.10 and Windows 7?

    - by Linda
    I'm using Ubuntu 11.10 32-bit and Windows 7 64-bit, however, Synergy only works when a window (application or folder) is open and touching the edge of the screen where the mouse should "jump". In other words, if a window is open and maximized, Synergy works normally. Without any windows, the mouse does not jump to the other screen. My steps: (Ubuntu) apt-get install -y quicksynergy (Windows) Install Synergy (I've tried both 1.3.8 and 1.4.8 and both 32 and 64-bit) On Ubuntu 11.10 32-bit (Synergy Server config): ~/.quicksynergy/synergy.conf section: screens myubuntu: mywin7: end section: links myubuntu: right = mywin7 mywin7: left = myubuntu end On Ubuntu 11.10 32-bit: $ /usr/bin/synergys -f --config .quicksynergy/synergy.conf ... 2012-04-25T14:04:12 NOTE: client "mywin7" has connected /build/buildd/synergy-1.3.6/lib/server/CServer.cpp,287 (output hangs here) On Windows 7 64-bit: Synergy 1.3.8 Client on Microsoft Windows 7 x86 (WOW64) started client connecting to 'myubuntu': ###.###.###.###:24800 connected to server (output hangs here) At this point, things should work, but my mouse still can't change screens unless a window is maximized on my Ubuntu machine. Everything is running on port 24800. No firewall on Ubuntu. Firewall port 24800 open on Windows 7. This was previously working on Ubuntu 10.10 and Windows 7 (so only Ubuntu has been upgraded). I'm open to using either 32 or 64-bit on either server or client side, but I just want to get it working on Ubuntu 11.10 and Windows 7! I'm also using Ubuntu Classic (no effects), and not Unity.

    Read the article

< Previous Page | 289 290 291 292 293 294 295 296 297 298 299 300  | Next Page >