  • Laptop CPU fan not working properly

    - by Smith
    My laptop's CPU fan is suddenly acting very bizarre, and I am at a loss for what to do so I am asking for some help. Specifically, the fan is not even starting to spin until the CPU reaches 60 degrees Celsius (checked through HWmonitor). Once it is on, however, it properly stays on even when the CPU gets back to idle temps around 38 Celsius. Before, the fan was simply starting with the computer and staying on like normal. I've checked this for consistency both by allowing cold boots to ramp up temperature to 60 Celsius (the slow climb also causing the laptop to become unreasonably warm near the heatsink), and also running Prime95 immediately to kickstart the fan (this works every time). The fan seems to be stationary when turning the computer on from either sleep or shutdown. The fan will start at POST very briefly, and then stop completely. I've checked the BIOS for a SmartFan setting but haven't found any. I've opened the case to check for dust or debris and have not found anything (I applied some canned air to the area just in case). The laptop is a Lenovo ThinkPad Edge E430 and the CPU is an Intel Core i5 3210m @ 2.5 GHz. Any advice would really be appreciated.

    Read the article

  • Server Cabinet/Room Cooling

    - by user37226
    Hello all. I currently have two desktops and three servers in my office sitting on the floor (I know this is bad). With that many servers the ambient temperature in the room goes up quickly. I am located in Dallas, TX so during the winter, if the heat is kept low, it is not a problem, but during the summer it easily jumps the room +10 degrees. I have decided and found a free 42U server cabinet that a hosting company was throwing away to house all of these systems in. One server is in a rack mount case while the other four servers are housed in mid-tower cases. I have purchased shelves for each computer and plan to lay the towers side ways on these shelves (as replacing the cases costs a heck of a lot of money). I like the idea of housing all of these systems in the cabinet because it will save a lot of room and clean up all of the cabling currently laying all over the office floor. When putting this setup together over the next couple of weeks, I want to address issues with dust and cooling. The server cabinet has a fan on top, front plexiglass door and a rear metal door with vent wholes on the bottom. First the cooling issues. I know I am going to want to have cool air enter the bottom of the cabinet and exit the top. I do not want the room heating up though as this will make my work area hot and then make the servers warmer as the air eventually reenters the cabinet. I had an idea to fix this problem, but am unsure if it will work. I was thinking of taking flexible piping and adapting it to the back fans of the computer having the other end of the pipe at the top close to the cabinet's top mounted fan. I was then thinking of creating a duct around the top fan into the attic. Now I am very concerned that the attic will cause issues with this type of setup because during July/August time frame, the attic is easily 120 degrees F. I could also use the flexible pipe to take it to an attic exhaust vent if it would be better to vent it into the 100 degree air outside (at least there may be wind. The other option would be to buy a small portable air conditioner. This may be a possibility, but do I want to spend the extra money on power? I bet this increases the noise. Plus they are around $250 on Amazon. What would you all recommend? Depending on the solution I end up running with above, I would also like to limit the dust that gets into the cabinet. If I were to cut a whole and mount a second cabinet fan on the bottom of the rear door, could I possibly mount a standard home air filter on the other side of that whole? Thanks in advance for your recommendations. I look forward to reading your interesting ideas.

    Read the article

  • Server Cabinet/Room Cooling

    - by user37226
    Hello all. I currently have two desktops and three servers in my office sitting on the floor (I know this is bad). With that many servers the ambient temperature in the room goes up quickly. I am located in Dallas, TX so during the winter, if the heat is kept low, it is not a problem, but during the summer it easily jumps the room +10 degrees. I have decided and found a free 42U server cabinet that a hosting company was throwing away to house all of these systems in. One server is in a rack mount case while the other four servers are housed in mid-tower cases. I have purchased shelves for each computer and plan to lay the towers side ways on these shelves (as replacing the cases costs a heck of a lot of money). I like the idea of housing all of these systems in the cabinet because it will save a lot of room and clean up all of the cabling currently laying all over the office floor. When putting this setup together over the next couple of weeks, I want to address issues with dust and cooling. The server cabinet has a fan on top, front plexiglass door and a rear metal door with vent wholes on the bottom. First the cooling issues. I know I am going to want to have cool air enter the bottom of the cabinet and exit the top. I do not want the room heating up though as this will make my work area hot and then make the servers warmer as the air eventually reenters the cabinet. I had an idea to fix this problem, but am unsure if it will work. I was thinking of taking flexible piping and adapting it to the back fans of the computer having the other end of the pipe at the top close to the cabinet's top mounted fan. I was then thinking of creating a duct around the top fan into the attic. Now I am very concerned that the attic will cause issues with this type of setup because during July/August time frame, the attic is easily 120 degrees F. I could also use the flexible pipe to take it to an attic exhaust vent if it would be better to vent it into the 100 degree air outside (at least there may be wind. The other option would be to buy a small portable air conditioner. This may be a possibility, but do I want to spend the extra money on power? I bet this increases the noise. Plus they are around $250 on Amazon. What would you all recommend? Depending on the solution I end up running with above, I would also like to limit the dust that gets into the cabinet. If I were to cut a whole and mount a second cabinet fan on the bottom of the rear door, could I possibly mount a standard home air filter on the other side of that whole? Thanks in advance for your recommendations. I look forward to reading your interesting ideas.

    Read the article

  • Ubuntu 9.0.4 Presario S4000NX Fan Speed

    - by Chris C
    I recently install Ubuntu 9.0.4 on a Presario S4000NX and the CPU fan speed is kept at max. With Windows XP installed the fan speed would increase/decrease as required. I've tried to install lm-sensors and run the sensors-detect. It recommended that I load the modules which I did: smsc47m192 i2c-i801 When running sensor-detect it gave me this strange message: Trying family SMSC Found SMSC LPC47M15x/192/997 Super IO Fan Sensors (but not activated) Running the sensors command gives me a list of voltages and CPU and temperature but doesn't list any fans. After doing some Internet research I then tried to load the smsc47m1 module but I get the following error: FATAL: Error inserting smsc47m1 (/lib/modules/2.6.28-15-generic/kernel/drivers/hwmon/smsc47m1.ko): no such device The file smsc47m1.ko does exist in the listed folder. Any suggestions for getting the fan speed (and the noise) down in Ubuntu? Thanx. - Chris P.S. - I would have put better tags but Server Fault wouldn't let me.

    Read the article

  • Low CPU usage but High fan speed

    - by dhasu
    The problem I am facing is the CPU fan rotates with high speed even though the CPU usage is very low, less than 10%. I even cleaned the Dust off the Fan, I replaced the Thermal Material on the Processor. Installed an Extra Fan. Nothing seems to Work. Please Help.

    Read the article

  • Notebook fan spinning at max after trying Linux

    - by Igor Kulman
    I have a Thinkpad T420 (4178-BSG) I use with Windows. The fan (cpu) was always very quiet and I was completely satisfied with it. A few days ago I booted Backtrack Linux from a flashdrive and the fan started to spin at maximum and was very loud. The problem is that this state persists. When I start the Thinkpad and boot Windows as usual the fan start spining at max and never stops. It drives me mad. It looks like somehow the Linux change some settings and I have to suffer. I tried reseting BIOS, updating BIOS, nothing helpes. I even removed the keyboard, looked at the fan but there is no dust.

    Read the article

  • High fan speed after return from suspend (on Ubuntu)

    - by Bolo
    Hi, I've got a HP ProBook 5310m laptop with Ubuntu 10.04 (32 bit). When I return from suspend, the fan speed is usually very high: FDTZ sensor reports "90 °C". Yes, the units are wrong, since FDTZ does not report temperature, but fan speed – that's probably just a small bug in reporting. Interestingly, when I plug or unplug the power cable for a moment, the fan speed returns back to normal. My questions: Where can I report this problem? Is it about ACPI support in the kernel? What is the address of the relevant bug tracker? As a workaround for now, how can I programmatically trigger a behavior equivalent to (un)plugging the power cable. More generally, how can I force ACPI to recalculate fan speed? Ideally, I'm looking for something like echo foo > /proc/bar. Thanks in advance!

    Read the article

  • Compaq Motherboard gives "CPU Fan Error"

    - by John
    I have a motherboard for a HP business desktop dx5150 PC. The model written on the board is "MS-7050" and it is for an AMD socket 939 processor. I got everything installed in it, and when I turned it on, it showed a message stating that there was a "CPU Fan Error" (or some similar language) and then turned off. It never stays on for more than about 30 seconds, probably less. The fan had previously been working great, but I replaced it anyway with a brand new Cooler Master fan. This did not work. I then reset the BIOS with the jumpers on the board, no dice. I replaced the CMOS battery. Same error. I then replaced the entire computer power supply with a brand new Antec, same error. The fan header is keyed, and has room for 3 pins. The CPU fan is designed the same way, so its not that I'm missing a temperature sensor or anything. Can anyone give some suggestions? Especially maybe some secret keystrokes to bypass this error?

    Read the article

  • ATI Radeon HD 5770 Cooling

    - by Murtez
    I have a Radeon HD 5770 manufactured by ATI. In the course of using compressed air to clean it the fan shattered. I put a case fan on the card to cool it, but it's not doing a great job; the temperature goes to nearly 100 sometimes. The card is not overclocked or anything, the PC itself is clean. I looked around for a third party cooling system but the only one I found was the Accelero L2 Pro. It's low on stock and I don't know how great it will be, some review say it may not fit on all 5770 cards. Does anyone know of another one that will work? Help is much appreciated.

    Read the article

  • Low Profile AMD Cooling

    - by J. T.
    I have a few setups where I can mount two motherboards on top of each other. They are running AMD Athlon 64 x2 dual core 4200 CPU's using a very low profile CPU cooler. These coolers are loud and annoying. Does anyone know of a low profile QUIET CPU cooling solution?

    Read the article

  • Water cooling parts

    - by Ursa
    Want to build something similar to this.http://www.engadget.com/2010/05/12/digital-storm-tempts-with-4-4ghz-black-ops-assassin-gaming-deskt/. Does anyone know where I can find the parts? Chasis and water cooling components.

    Read the article

  • Low Profile AMD Cooling

    - by J. T.
    I have a few setups where I can mount two motherboards on top of each other. They are running AMD Athlon 64 x2 dual core 4200 CPU's using a very low profile CPU cooler. These coolers are loud and annoying. Does anyone know of a low profile QUIET CPU cooling solution?

    Read the article

  • Cooling for a small server room

    - by John Zwinck
    I have a server room about 12 feet square with an unfinished ceiling (exposed ducts and wiring). It houses a few servers (about ten, 1U and 2U) and some networking gear (four 1U switches, three routers, three modems, two cable boxes). With the door closed, it runs around 80 degrees Fahrenheit with half the servers turned on. When I turned on all the servers it reached 86 before I chickened out and propped the door open. The room is adjacent to air-conditioned office space, but does not itself have dedicated air conditioning. The ventilation for this room seems to be limited to one duct coming in at ceiling level, with a powered fan to draw air in, and one duct at ceiling level to allow air to flow out (it seems like it may just go into the drop ceiling cavity in the adjacent room). The adjacent office space stays fairly cool, but I'd prefer not to leave the door propped open all the time. There is both 110v and 208v service in the room, and plenty of power available. But there are no windows, and no floor drains (in a pinch we might be able to run a condensation hose through a small hole we'd drill in the wall to a nearby sink area, but only if absolutely necessary). I've considered portable A/C units, but I'm not sure on sizing and a lot less sure how we would run the exhaust hose(s). I suppose we could point one at the existing room exhaust duct (air return), but substantially modifying the duct is probably a no-no. I've also considered installing a fan box in the door of the room, but I'm concerned that this will only drop the temperature a little. Even right now, with all the equipment on, the room is at 83 degrees with the door open. And the main building A/C turns off daily at 6 PM to conserve energy, so the adjacent room temperature rises at night. How would you cool this room? Let's say the goal is to bring the temperature with everything running from a steady state of around 90 degrees down to 75 (equivalently, to offset the heat produced by ten 1U servers).

    Read the article

  • Cooling a large laptop

    - by sazabi02
    I've had my first laptop early this year and I haven't the slightest idea how to make it cooler. No real problems when I don't use graphics intensive games but when I play games like Dragon Age the temps rise up from 55 to 85. I'm concerned as a friend tells me that HP laptops aren't reputed to last long when it comes to heat. BTW, I've already bought a cooling pad with 3 fans and it didn't do much that elevating it and pointing an electric fan at it didn't do before. Additionally, this is a 17 inch HP dv7-3085dx entertainment notebook that i'm using.

    Read the article

  • Why is my CPU fan so loud?

    - by tiiquu
    I bought an old PC to use as a second PC. Everything is fine, except for one thing. The CPU fan is terribly loud! I did a lot with PCs but I never did much with CPU fans. If I want to replace it, what do I have to look for? The fan is 8cm long on each side and 11cm diameter. It is just clipped to the cooler. The PC is a P4 3 GHz. I don't want to spend much money, as I only paid 50 euro for the whole PC. I would prefer to buy a fan for 1-3 dollar or something at eBay but I am not quite sure which one I should buy (which fits). Can you advise?

    Read the article

  • Coolbits not working

    - by usk
    I want to use coolbits to increase fan speed of my Fermi GPU. 280.13 driver installed. Ubuntu 11.10 I edited /etc/X11/xorg.conf as follows, by pressing Alt+F2 and gksu gedit /etc/X11/xorg.conf I get Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "GeForce GTX 470" Option "NoLogo" "True" Option "Coolbits" "4" EndSection Started getting these messages, Gtk-WARNING **: Unable to locate theme engine in module_path: "pixmap" So I did this, sudo aptitude install gtk2-engines-pixbuf terminal, a@z:~$ nvidia-settings -a [gpu:0]/GPUFanControlState=1 a@z:~$ nvidia-settings -q fans 1 Fan on z:0 [0] z:0[fan:0] (Fan 0) a@z:~$ nvidia-settings -a [fan:0]/GPUCurrentFanSpeed=80 ERROR: Error assigning value 80 to attribute 'GPUCurrentFanSpeed' (z:0[fan:0]) as specified in assignment '[fan:0]/GPUCurrentFanSpeed=80' (Unknown Error). So, it's not working; I can't enter the fan speed percentage. Also from NVidia X Server, there are no fan controls. http://en.gentoo-wiki.com/wiki/Nvidia#Manual_Fan_Control_for_nVIDIA_Settings

    Read the article

  • Fan speed monitor Software for Macbook Pro Unibody on Windows

    - by dtmunir
    I've tried multiple temperature monitor and fan speed software on my Macbook Pro Unibody under Windows 7 64-bit RC. None of them can report the fan speed. Currently I'm using SpeedFan which reports the CPU temperature of each of the two cores, but is not able to detect or interface with the Fans. Has anyone had any luck with this?

    Read the article

  • loud fan on laptop

    - by Doug
    My laptop (hp dv6500t) fan is really loud! What can I do to decrease the sound? I checked the bios with no options and I can't used speedfna because it doesn't work. Can I chagbe it's faN Edit: I already cleaned out the fans and even added artic silver 5. It's loud where people can hear it accross the classroom.

    Read the article

  • Brand new Mac Pro tower fan suddenly runs full-tilt

    - by Caffeine Coma
    My Quad-Core Mac Pro tower is two days old. Initially, I was impressed with how quiet it was compared to my older Macbook Pro. Then on day two, for some reason it started running very loudly. It's not just a "little" loud- my wife walked into the room and asked what the noise was. At first I thought this was just because I was hitting the CPU a bit (importing my iPhone library into iLife '09, and running Eclipse). But now that that's done, Activity Monitor shows a virtually idle CPU; there's nothing running that ought to be causing this, as far as I can tell. I tried powering it off & letting it cool down for a few minutes to no avail; about 10 seconds after powering up, the box gets loud again. I took a look at it with the side cover off, and it seems to be the fan near the top middle, between the power supply and the disk drive. It can't be a dust issue, as the machine is only 2 days old (and I peeked inside anyway just to be sure- clean). I did do a software update over the past 24 hours or so, but I can't say that it occurred immediately after that. I also did a migration of my old apps and data from my MBPro, for what it's worth. Why is it suddenly so loud? How can I monitor the fan speed and various system temperatures? Here's a link to my temps and fan speeds. UPDATE 1: Took it to the Apple Store. They took it in the back (where it's presumably quieter) and ran a fan diagnostic; no problems were found. The guy also told me that it was "a little loud", but normal. I don't buy it. It was virtually silent the first 24 hours I was using it. They would not replace/service it in the store (grrr... that's why I went there, as directed by Apple Care) but said I could get a replacement from the online store, as it was just purchased. I think I will try that. UPDATE 2: Apple is letting me send it back for a replacement. Glad to see so many responses to this question mentioning that the MacPros are usually silent; it's not all just in my head. :-)

    Read the article

  • fan adapter required for 2 controlers

    - by spy
    good day i would like to ask if i can connect the same fan to 2 fan controllers at the same time, if so how do i go about it please, i bought http://www.ebay.co.uk/itm/121255084003?ssPageName=STRK:MEWNX:IT&_trksid=p3984.m1497.l2649 wich has a loger cable and sits on my table and http://www.ebay.co.uk/itm/111365380971?ssPageName=STRK:MEWNX:IT&_trksid=p3984.m1497.l2649 sits in the tower and facing away from me.

    Read the article

  • High fan speed with no reason

    - by Klaus
    For a few weeks, the fans of my Lenovo B590 laptop, running on Xubuntu 14, turn to high speed a few minutes after it is turned on. The fans won't speed down until I turn the computer off. This is quite strange, since This didn't happen before The temperatures are quite low (are they ?) $sensors Adapter: Virtual device temp1: +36.0°C (crit = +88.0°C) temp2: +30.0°C (crit = +126.0°C) coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +37.0°C (high = +72.0°C, crit = +90.0°C) Core 0: +34.0°C (high = +72.0°C, crit = +90.0°C) Core 1: +31.0°C (high = +72.0°C, crit = +90.0°C) thinkpad-isa-0000 Adapter: ISA adapter fan1: 0 RPM pkg-temp-0-virtual-0 Adapter: Virtual device temp1: +37.0°C $sudo hddtemp /dev/sda /dev/sda: ST500LT012-9WS142: 33°C The computer is under low load: top - 08:30:15 up 16 min, 2 users, load average: 0.28, 0.23, 0.23 Tasks: 197 total, 1 running, 196 sleeping, 0 stopped, 0 zombie %Cpu(s): 0.8 us, 0.5 sy, 0.0 ni, 98.7 id, 0.0 wa, 0.0 hi, 0.0 si, 0.0 st KiB Mem: 3607944 total, 1973956 used, 1633988 free, 99660 buffers KiB Swap: 3744764 total, 0 used, 3744764 free. 789936 cached Mem The BIOS is up to date (and there are no fan settings in it) The fan is clean and dust-free Why would the BIOS turn the fans to high speed where there seem to be no reason for that ? It seems that we cannot control the fan manually with this model, so I guess the only solution is to understand why this happens.

    Read the article

  • Facebook API: How to let the php knows whether the user is a fan of the application or not?

    - by Unreality
    Facebook API: How to let the php knows whether the user is a fan of the application or not? Plan 1: failed is displayed at the html level only.. .it won't let the php level knows whether the user is a fan or not Plan 2: failed has got the same problem too Plan 3: failed fql permission table simply lacked the field of is_fan http://wiki.developers.facebook.com/index.php/Permissions_%28FQL%29 Plan 4: server lag calling restful API http://wiki.developers.facebook.com/index.php/Pages.isFan will bring a lot of lag to server... and I wonder if it can works on application page too. any suggestion to solve this problem?

    Read the article