Search Results

Search found 28613 results on 1145 pages for 'default parameters'.

Page 3/1145 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Why are there two implementations of std::sort (with and without a comparator) rather than one implementation with a default template parameter?

    - by PolyVox
    In my code I'm adopting a design strategy which is similar to some standard library algorithms in that the exact behavior can be customized by a function object. The simplest example is std::sort, where a function object can control how the comparison is made between objects. I notice that the Visual C++ provides two implementations of std::sort, which naturally involves code duplication. I would have imagined that it was instead possible to have only one implementation, and provide a default comparator (using operator< ) as a default template parameter. What is the rational behind two separate versions? Would my suggestion make the interface more complex in some way? Or result in confusing error messages when the object does not provide operator Thanks, David

    Read the article

  • Windows 7 DHCP Default Gateway not Overridden by manual Default Gateway

    - by dgwilson
    We have recently installed Windows 7 for student computers. All student computers must be routed through our content filter which is located at 192.168.0.63. This was done in WinXP by adding a Default Gateway in the network adapter settings TCP/IP Properties Advanced Default Gateway. All teacher computers are routed through the DHCP assigned Default Gateway of 192.168.0.1. In WinXP the dhcp default gateway was correctly overridden by this manual setting. In Win7 it appears that the dhcp default gateway is retained and the manual one is added to the list so that there are two with the dhcp one having the primary metric. I have tried several ways to remove the dhcp default gateway such as, running the "route delete 0.0.0.0 192.168.0.1" command. Doing this from an administrator command prompt works but it just resets upon reboot. I've tried adding this command to the registry's Run section but it seems to run as a non-administrator and therefore will not complete successfully. Is there any way to prevent this and force the manual default gateway to override the dhcp one? Or to remove the dhcp assigned one automatically on boot/login? HELP! We CANNOT allow student computers to connect to the internet without going through the content filter.

    Read the article

  • Windows 7 DHCP Default Gateway not Overridden by manual Default Gateway

    - by dgwilson
    We have recently installed Windows 7 for student computers. All student computers must be routed through our content filter which is located at 192.168.0.63. This was done in WinXP by adding a Default Gateway in the network adapter settings TCP/IP Properties Advanced Default Gateway. All teacher computers are routed through the DHCP assigned Default Gateway of 192.168.0.1. In WinXP the dhcp default gateway was correctly overridden by this manual setting. In Win7 it appears that the dhcp default gateway is retained and the manual one is added to the list so that there are two with the dhcp one having the primary metric. I have tried several ways to remove the dhcp default gateway such as, running the "route delete 0.0.0.0 192.168.0.1" command. Doing this from an administrator command prompt works but it just resets upon reboot. I've tried adding this command to the registry's Run section but it seems to run as a non-administrator and therefore will not complete successfully. Is there any way to prevent this and force the manual default gateway to override the dhcp one? Or to remove the dhcp assigned one automatically on boot/login? HELP! We CANNOT allow student computers to connect to the internet without going through the content filter.

    Read the article

  • AIX network parameters to close TCP sockets of unplugged devices

    - by ADD Geek
    Hi there We have an AIX box, running what we call in banking "ATM Switch" not the ATM networking switch, but the bank ATM driver. where we have some ATM machines connected to two server processes. The problem is, when we disconnect any of these machines, the netstat -na| grep <port number> command shows that the socket established for this disconnected device is still established, we have to manually send a command from the software to make the socket aware that it is not live anymore. Is there a parameter on tcp level to make this connection aware within a minute or two that this device is not connected anymore? we had the following parameters set with root privileges: no -o tcp_keepidle=1000 no -o tcp_keepcnt=2 no -o tcp_keepintvl=150 no -o tcp_finwait2=100 it was originally having the default values. but even after we changed these parameters and restarted the server processes, the problem was still there.

    Read the article

  • MySQL Stored Procedure Parameters are NULL

    - by emmilely
    I am stumped, and was hoping someone here would have a quick and easy answer. I did a fresh install of MySQL 5.5 and am trying to pass parameters into a stored procedure. The parameter values aren't being read by the stored procedure. MySQL doesn't throw an error and processes the code with null parameters. Here is the code: DELIMITER $$ CREATE DEFINER=`root`@`%` PROCEDURE `testing`(IN parameter INTEGER) BEGIN UPDATE table_name SET valueToChange = 'Test' WHERE mainID = @parameter; END And here is the query I'm using to call it: USE database_name; CALL testing(72); Can anyone help?

    Read the article

  • Target line parameters for shortcuts in Windows Explorer?

    - by Charles E. Gates Jr.
    I am using Windows 7 and I am looking for a list of the different parameters to use in the Target line of a shortcut in Windows Explorer. For example: /n forces it to open a new window, even if it duplicates a window that is already open. /e uses Windows Explorer view (multi-paned) /root,X restricts Explorer to showing only the contents of file folder X (and its sub-folders) /select,Y automatically selects Y (either a file or folder). What other parameters exist? I have been searching online and cannot find anything.

    Read the article

  • Use of Business Parameters in BPM12c

    - by Abhishek Mittal-Oracle
    With the release of BPM12c, a new feature to use Business Parameters is introduced through which we can define a business parameter which will behave as a global variable which can be used within BPM project. Business Administrator can be the one responsible to modify the business parameters value dynamically at run-time which may bring change in BPM process flow where it is used.This feature was a part of BPM10g product and was extensively used. In BPM11g, this feature is not present currently.Business Parameters can be defined in 2 ways:1. Using Jdev to define business parameters, and 2. Using BPM workspace to define business parameters.It is important to note that business parameters need to be mapped with a valid organisation unit defined in a BPM project. If the same is not handled, exceptions like 'BPM-70702' will be thrown by BPM Engine. This is because business parameters work along with organisation defined in a BPM project.At the same time, we can use same business parameter across different organisation units with different values. Business Parameters in BPM12c has this capability to handle multiple values with different organisation units defined in a single BPM project. This enables business to re-use same business parameters defined in a BPM project across different organisations.Business parameters can be defined using the below data types:1. int2. string 3. boolean4. double While defining an business parameter, it is mandatory to provide a default value. Below are the steps to define a business parameter in Jdev: Step 1:  Open 'Organization' and click on 'Business Parameters' tab.Step 2:  Click on '+' button.Step 3: Add business parameter name, type and provide default value(mandatory).Step 4: Click on 'OK' button.Step 5: Business parameter is defined. Below are the steps to define a business parameter in BPM workspace: Step 1: Login to BPM workspace using admin-username and password.Step 2: Click on 'Administration' on the right top side of workspace.Step 3: Click on 'Business Parameters' in the left navigation panel under 'Organization'. Step 4:  Click on '+' button.Step 5: Add business parameter name, type and provide default value(mandatory).Step 6: Click on 'OK' button.Step 7: Business parameter is defined. Note: As told earlier in the blog, it is necessary to define and map a valid organization ID with predefined variable 'organizationalUnit' under data associations in an BPM process before the business parameter is used. I have created one sample PoC demonstrating the use of Business Parameters in BPM12c and it can be found here.

    Read the article

  • Configuring default gateway returned by dhcp server

    - by comp1mp
    Hello, I have a machine which connects via ethernet to a private LAN, and wireless to a network which provides internet connectivity. The private LAN uses a wireless router to perform DHCP. The problem is that the wireless and NIC adapters have different default gateways. The default gateway for the private LAN has a lower adapter metric, and is thus chosen by the routing algorithm. I am thus unable to browse the internet when connected to both adapters. The following link has a solution for manually setting the adapter metric to a high number. http://superuser.com/questions/77822/how-to-tell-windows-7-to-ignore-a-default-gateway I was hoping to find a different solution. Does any one know of a router that allows you to configure its DHCP server to return an empty default gateway? I cannot find such an option for my linksys wrt300n. Configuring a static ip address with no default gateway does work, however I would like to use DHCP if possible. Does anyone know of a different way to specify a default gateway for a windows 7 machine with multiple network adapters without mucking with the adapter metric? Thanks, Matthew

    Read the article

  • Can't figure out jQuery ajax call parameters

    - by chad larson
    I am learning jQuery and trying the following but the parameters are so foreign to me with all the embedded quotes I think that is my problem. Can someone explain the parameters and where quotes go and possibly rewrite my parameters line? (This is a live site to see the required parms). function AirportInfo() { var divToBeWorkedOn = '#detail'; var webMethod = "'http://ws.geonames.org/citiesJSON'"; var parameters = "{'north':'44.1','south':'9.9','east':'22.4','west':'55.2','lang':'de'}"; $.ajax({ type: "POST", url: webMethod, data: parameters, contentType: "application/json; charset=utf-8", dataType: "json", success: function(msg) { alert(msg.d); $(divToBeWorkedOn).html(msg.d); }, error: function(xhr) { alert(xhr); alert(xhr.statusText); alert(xhr.responseText); $(divToBeWorkedOn).html("Unavailable"); } }); }

    Read the article

  • Superfluous python parameters

    - by Leif Andersen
    I've noticed a discrepancy in the way that python parameters are called. In every other language I've dealt with, you either have foo() meaning either no parameters, or as many parameters as you like, or foo(arg1, arg2,...,argn) where you pass in the same number of parameters to define the function and call it. In python however, I've noticed that the function definitions, and when the function is called, can have two different parameters sets, this usually consists of: class foo(object): def bar(self, arg1, arg2): pass However, when I want to call the function, all I have to do is: zoo = foo() zoo.bar(arg1, arg2) Where did the self parameter go? Thank you.

    Read the article

  • Passing parameters to telerik asp.net mvc grid

    - by GlobalCompe
    I have a telerik asp.net mvc grid which needs to be populated based on the search criteria the user enters in separate text boxes. The grid is using ajax method to load itself initially as well as do paging. How can one pass the search parameters to the grid so that it sends those parameters "every time" it calls the ajax method in response to the user clicking on another page to go to the data on that page? I read the telerik's user guide but it does not mention this scenario. The only way I have been able to do above is by passing the parameters to the rebind() method on client side using jquery. The issue is that I am not sure if it is the "official" way of passing parameters which will always work even after updates. I found this method on this post on telerik's site: link text I have to pass in multiple parameters. The action method in the controller when called by the telerik grid runs the query again based on the search parameters. Here is a snippet of my code: $("#searchButton").click(function() { var grid = $("#Invoices").data('tGrid'); var startSearchDate = $("#StartDatePicker-input").val(); var endSearchDate = $("#EndDatePicker-input").val(); grid.rebind({ startSearchDate: startSearchDate , endSearchDate: endSearchDate }); } );

    Read the article

  • How to get all active parameters in ASP.NET MVC (2)

    - by SztupY
    Hi! I was wondering whether there is a way to create an ActionLink or similar, that changes only a few parameters of the actual query, and keeps all the other parameters intact. For example if I'm on an URL like http://example.com/Posts/Index?Page=5&OrderBy=Name&OrderDesc=True I want to change only the Page, or OrderBy parameter and keep all other parameters the same, even those I don't yet know of (like when I want to add a Search parameter or something similar too). The header of my current action looks like this: public ActionResult Index(int? Page, string OrderBy, bool? Desc) and I'm only interested in the values that this controller "eats". I want however that when I extend this action (for example with a string Search parameter) the links should work the same way as before. Here is what I did already: Create a new RouteValueDictionary and fill it with everything from RouteData.Values Problem: This only fills the parameters that are used in the Routing, so all other optional parameters (like Page) to the controller are lost Add everything from HttpContext.Request.QueryString to the previous dictionary This is what I am currently using Problem: It might have some junk stuff, that the Controller didn`t ask for, and it doesn't work if the page was loaded using POST. You also don't have any ModelBindings (but this isn't much of a problem, because we are re-sending everything anyway) Use HttpContext.Request.Params Problem: this has too much junk data which imho one shouldn't add to a RouteValueDictionary that is passed to an ActionLink So the questions: Is there an RVD that has all the data that was passed to the Controller and was used by it? Is this solution good, or are there any caveats I didn't think about (mainly in the context of changing a few query parameters while keeping the others intact)? Is there a way to filter out the "junk" data from the Params object?

    Read the article

  • converting mysql database to sql server

    - by every_answer_gets_a_point
    i have a mysql database: /* MySQL Data Transfer Source Host: 10.0.0.5 Source Database: jnetdata Target Host: 10.0.0.5 Target Database: jnetdata Date: 5/26/2009 12:27:33 PM */ SET FOREIGN_KEY_CHECKS=0; -- ---------------------------- -- Table structure for chavrusas -- ---------------------------- CREATE TABLE `chavrusas` ( `id` int(11) NOT NULL auto_increment, `date_created` datetime default NULL, `luser_id` int(11) default NULL, `ruser_id` int(11) default NULL, `luser_type` varchar(50) default NULL, `ruser_type` varchar(50) default NULL, `SessionDay` varchar(250) default NULL, `SessionTime` datetime default NULL, `WeeklyReminder` tinyint(1) NOT NULL default '0', `reminder_phone` tinyint(1) NOT NULL default '0', `calling_card` varchar(50) default NULL, `active` tinyint(1) NOT NULL default '0', `notes` mediumtext, `ended` tinyint(1) NOT NULL default '0', `end_date` datetime default NULL, `initiated_by_student` tinyint(1) NOT NULL default '0', `initiated_by_volunteer` tinyint(1) NOT NULL default '0', `student_general_reason` varchar(50) default NULL, `volunteer_general_reason` varchar(50) default NULL, `student_reason` varchar(250) default NULL, `volunteer_reason` varchar(250) default NULL, `student_nli` tinyint(1) NOT NULL default '0', `volunteer_nli` tinyint(1) NOT NULL default '0', `jnet_initiated` tinyint(1) default '0', `belongs_to` varchar(50) default NULL, PRIMARY KEY (`id`) ) ENGINE=MyISAM AUTO_INCREMENT=5913 DEFAULT CHARSET=latin1; -- ---------------------------- -- Table structure for tbluseravailability -- ---------------------------- CREATE TABLE `tbluseravailability` ( `availability_id` int(11) NOT NULL auto_increment, `user_id` int(11) NOT NULL, `weekday_id` int(11) NOT NULL, `timeslot_id` int(11) NOT NULL, PRIMARY KEY (`availability_id`) ) ENGINE=MyISAM AUTO_INCREMENT=10865 DEFAULT CHARSET=latin1; -- ---------------------------- -- Table structure for tblusers -- ---------------------------- CREATE TABLE `tblusers` ( `id` int(11) NOT NULL auto_increment, `password` varchar(50) default NULL, `title` varchar(255) default NULL, `first` varchar(255) default NULL, `last` varchar(255) default NULL, `gender` varchar(255) default NULL, `address` varchar(255) default NULL, `address_2` varchar(255) default NULL, `city` varchar(255) default NULL, `state` varchar(255) default NULL, `postcode` varchar(255) default NULL, `country` varchar(255) default NULL, `email` varchar(255) default NULL, `emailnotes` varchar(255) default NULL, `Home_Phone` varchar(255) default NULL, `Office_Phone` varchar(255) default NULL, `Cell_Phone` varchar(255) default NULL, `Contact_Preference` varchar(255) default NULL, `Birthdate` datetime default NULL, `Age` varchar(255 and it goes on for about 10mb i need to convert it to ms sql, how do i do it?

    Read the article

  • Using Table-Valued Parameters With SQL Server Reporting Services

    - by Jesse
    In my last post I talked about using table-valued parameters to pass a list of integer values to a stored procedure without resorting to using comma-delimited strings and parsing out each value into a TABLE variable. In this post I’ll extend the “Customer Transaction Summary” report example to see how we might leverage this same stored procedure from within an SQL Server Reporting Services (SSRS) report. I’ve worked with SSRS off and on for the past several years and have generally found it to be a very useful tool for building nice-looking reports for end users quickly and easily. That said, I’ve been frustrated by SSRS from time to time when seemingly simple things are difficult to accomplish or simply not supported at all. I thought that using table-valued parameters from within a SSRS report would be simple, but unfortunately I was wrong. Customer Transaction Summary Example Let’s take the “Customer Transaction Summary” report example from the last post and try to plug that same stored procedure into an SSRS report. Our report will have three parameters: Start Date – beginning of the date range for which the report will summarize customer transactions End Date – end of the date range for which the report will summarize customer transactions Customer Ids – One or more customer Ids representing the customers that will be included in the report The simplest way to get started with this report will be to create a new dataset and point it at our Customer Transaction Summary report stored procedure (note that I’m using SSRS 2012 in the screenshots below, but there should be little to no difference with SSRS 2008): When you initially create this dataset the SSRS designer will try to invoke the stored procedure to determine what the parameters and output fields are for you automatically. As part of this process the following dialog pops-up: Obviously I can’t use this dialog to specify a value for the ‘@customerIds’ parameter since it is of the IntegerListTableType user-defined type that we created in the last post. Unfortunately this really throws the SSRS designer for a loop, and regardless of what combination of Data Type, Pass Null Value, or Parameter Value I used here, I kept getting this error dialog with the message, "Operand type clash: nvarchar is incompatible with IntegerListTableType". This error message makes some sense considering that the nvarchar type is indeed incompatible with the IntegerListTableType, but there’s little clue given as to how to remedy the situation. I don’t know for sure, but I think that behind-the-scenes the SSRS designer is trying to give the @customerIds parameter an nvarchar-typed SqlParameter which is causing the issue. When I first saw this error I figured that this might just be a limitation of the dataset designer and that I’d be able to work around the issue by manually defining the parameters. I know that there are some special steps that need to be taken when invoking a stored procedure with a table-valued parameter from ADO .NET, so I figured that I might be able to use some custom code embedded in the report  to create a SqlParameter instance with the needed properties and value to make this work, but the “Operand type clash" error message persisted. The Text Query Approach Just because we’re using a stored procedure to create the dataset for this report doesn’t mean that we can’t use the ‘Text’ Query Type option and construct an EXEC statement that will invoke the stored procedure. In order for this to work properly the EXEC statement will also need to declare and populate an IntegerListTableType variable to pass into the stored procedure. Before I go any further I want to make one point clear: this is a really ugly hack and it makes me cringe to do it. Simply put, I strongly feel that it should not be this difficult to use a table-valued parameter with SSRS. With that said, let’s take a look at what we’ll have to do to make this work. Manually Define Parameters First, we’ll need to manually define the parameters for report by right-clicking on the ‘Parameters’ folder in the ‘Report Data’ window. We’ll need to define the ‘@startDate’ and ‘@endDate’ as simple date parameters. We’ll also create a parameter called ‘@customerIds’ that will be a mutli-valued Integer parameter: In the ‘Available Values’ tab we’ll point this parameter at a simple dataset that just returns the CustomerId and CustomerName of each row in the Customers table of the database or manually define a handful of Customer Id values to make available when the report runs. Once we have these parameters properly defined we can take another crack at creating the dataset that will invoke the ‘rpt_CustomerTransactionSummary’ stored procedure. This time we’ll choose the ‘Text’ query type option and put the following into the ‘Query’ text area: 1: exec('declare @customerIdList IntegerListTableType ' + @customerIdInserts + 2: ' EXEC rpt_CustomerTransactionSummary 3: @startDate=''' + @startDate + ''', 4: @endDate='''+ @endDate + ''', 5: @customerIds=@customerIdList')   By using the ‘Text’ query type we can enter any arbitrary SQL that we we want to and then use parameters and string concatenation to inject pieces of that query at run time. It can be a bit tricky to parse this out at first glance, but from the SSRS designer’s point of view this query defines three parameters: @customerIdInserts – This will be a Text parameter that we use to define INSERT statements that will populate the @customerIdList variable that is being declared in the SQL. This parameter won’t actually ever get passed into the stored procedure. I’ll go into how this will work in a bit. @startDate – This is a simple date parameter that will get passed through directly into the @startDate parameter of the stored procedure on line 3. @endDate – This is another simple data parameter that will get passed through into the @endDate parameter of the stored procedure on line 4. At this point the dataset designer will be able to correctly parse the query and should even be able to detect the fields that the stored procedure will return without needing to specify any values for query when prompted to. Once the dataset has been correctly defined we’ll have a @customerIdInserts parameter listed in the ‘Parameters’ tab of the dataset designer. We need to define an expression for this parameter that will take the values selected by the user for the ‘@customerIds’ parameter that we defined earlier and convert them into INSERT statements that will populate the @customerIdList variable that we defined in our Text query. In order to do this we’ll need to add some custom code to our report using the ‘Report Properties’ dialog: Any custom code defined in the Report Properties dialog gets embedded into the .rdl of the report itself and (unfortunately) must be written in VB .NET. Note that you can also add references to custom .NET assemblies (which could be written in any language), but that’s outside the scope of this post so we’ll stick with the “quick and dirty” VB .NET approach for now. Here’s the VB .NET code (note that any embedded code that you add here must be defined in a static/shared function, though you can define as many functions as you want): 1: Public Shared Function BuildIntegerListInserts(ByVal variableName As String, ByVal paramValues As Object()) As String 2: Dim insertStatements As New System.Text.StringBuilder() 3: For Each paramValue As Object In paramValues 4: insertStatements.AppendLine(String.Format("INSERT {0} VALUES ({1})", variableName, paramValue)) 5: Next 6: Return insertStatements.ToString() 7: End Function   This method takes a variable name and an array of objects. We use an array of objects here because that is how SSRS will pass us the values that were selected by the user at run-time. The method uses a StringBuilder to construct INSERT statements that will insert each value from the object array into the provided variable name. Once this method has been defined in the custom code for the report we can go back into the dataset designer’s Parameters tab and update the expression for the ‘@customerIdInserts’ parameter by clicking on the button with the “function” symbol that appears to the right of the parameter value. We’ll set the expression to: 1: =Code.BuildIntegerListInserts("@customerIdList ", Parameters!customerIds.Value)   In order to invoke our custom code method we simply need to invoke “Code.<method name>” and pass in any needed parameters. The first parameter needs to match the name of the IntegerListTableType variable that we used in the EXEC statement of our query. The second parameter will come from the Value property of the ‘@customerIds’ parameter (this evaluates to an object array at run time). Finally, we’ll need to edit the properties of the ‘@customerIdInserts’ parameter on the report to mark it as a nullable internal parameter so that users aren’t prompted to provide a value for it when running the report. Limitations And Final Thoughts When I first started looking into the text query approach described above I wondered if there might be an upper limit to the size of the string that can be used to run a report. Obviously, the size of the actual query could increase pretty dramatically if you have a parameter that has a lot of potential values or you need to support several different table-valued parameters in the same query. I tested the example Customer Transaction Summary report with 1000 selected customers without any issue, but your mileage may vary depending on how much data you might need to pass into your query. If you think that the text query hack is a lot of work just to use a table-valued parameter, I agree! I think that it should be a lot easier than this to use a table-valued parameter from within SSRS, but so far I haven’t found a better way. It might be possible to create some custom .NET code that could build the EXEC statement for a given set of parameters automatically, but exploring that will have to wait for another post. For now, unless there’s a really compelling reason or requirement to use table-valued parameters from SSRS reports I would probably stick with the tried and true “join-multi-valued-parameter-to-CSV-and-split-in-the-query” approach for using mutli-valued parameters in a stored procedure.

    Read the article

  • Type classes or implicit parameters? What do you prefer and why? [closed]

    - by Petr Pudlák
    I was playing a bit with Scalaz and I realized that Haskell's type classes are very similar to Scala's implicit parameters. While Haskell passes the methods defined by a type class using hidden dictionaries, Scala allows a similar thing using implicit parameters. For example, in Haskell, one could write: incInside :: (Functor f) => f Int -> f Int incInside = fmap (+ 1) and the same function using Scalaz: import scalaz._; import Scalaz._; def incInside[F[_]](x: F[Int])(implicit fn: Functor[F]): F[Int] = fn.fmap(x, (_:Int) + 1); I wonder: If you could choose (i.e. your favorite language would offer both), what would you pick - implicits or type classes? And what are your pros/cons?

    Read the article

  • Dummy/default page for apache

    - by Ency
    I'm trying to set up default page for my apache2, for following cases: User is accessing http://IP_Address instead of hostname Requested protocol (HTTP/HTTPS) is not available (eg. only http*s*://domain.com exists) Currently I've got something like that <VirtualHost eserver:80> ServerAdmin webmaster@localhost DocumentRoot /var/www/local/ <Directory /> Options FollowSymLinks AllowOverride None </Directory> </VirtualHost> I think, it works well, i'm trying to do similar thing for HTTPS, but it does not work. <VirtualHost eserver:443> SSLCertificateKeyFile /etc/apache2/ssl/dummy.key SSLCertificateFile /etc/apache2/ssl/dummy.crt SSLProtocol all SSLCipherSuite HIGH:MEDIUM ErrorLog /var/log/apache2/error.log # Possible values include: debug, info, notice, warn, error, crit, # alert, emerg. LogLevel warn ServerSignature Off </VirtualHost> My default is places in sites-enabled as a first one 000-default I do not care about not certificate validity during accessing default page, my goal is not show different HTTPS page if user one of points is applied

    Read the article

  • Gentoo baselayout-2 problem with module parameters

    - by Alakdae
    I recently switched to baselayout-2 on my Gentoo machine but I have one problem. I autoload a module bttv with paramater: card=77,77 The problem is that at boot the module is loaded without the parameter which makes the video feed useless. I cannot find the cause because the funny thing is that when I put an echo in /etc/init.d/modules to see what is passed to modprobe, this is what I got: szymanowicz ~ # /etc/init.d/modules restart * WARNING: you are stopping a boot service * Caching service dependencies ... [ ok ] * Loading module bttv ... bttv card=77,77 [ ok ] * Autoloaded 1 module(s) It indicates that everything is OK, but dmesg shows that at boot time there are no parameters. bttv0: using: *** UNKNOWN/GENERIC *** [card=0,autodetected] ... bttv1: using: *** UNKNOWN/GENERIC *** [card=0,autodetected] Whereas when I run it manually I get: bttv0: using: GrandTec Multi Capture Card (Bt878) [card=77,insmod option] ... bttv1: using: GrandTec Multi Capture Card (Bt878) [card=77,insmod option] Please help me because reloading the modules every time there is a reboot is very anoying (not many reboots, but I need to remember about the module)

    Read the article

  • .htaccess redirect, from old dirty URL to a clean new URL with parameters

    - by JustAnil
    I have the following 2 links, I'm not great with .htaccess rules yet. Old URL: http://www.mywebsite.org.uk/donate/donate.php?charity_id=885&project_id=18111 New URL: http://new.mywebsite.org.uk/donation/to/885/18111 I want all the traffic coming from the old URL to the new url (including the parameters charity_id & project_id). I'm trying to learn .htaccess rules, but finding the tutorials online to be kinda vague. I'd really like a simple explanation on the .htaccess rules. (Give a man a fish, feed him for a day, teach a man to fish, feed him for a lifetime). The correct answer will be the answer with a simple and useful explanation (along with the rules if possible!).

    Read the article

  • How do you globally set the default browser using KDE4?

    - by wishi
    Hi! I'm using awesome-wm on Kubuntu 10.10. I like some of the KDE tools... like choqok. Thing is, that within awesome wm it seems to be impossible to set a default browser, because KDE4 settings overwrite the generally desired settings: To illustrate the problem: % xdg-mime query default text/html chromium-browser.desktop And from ~/.kde/share/config/kdeglobals [General] BrowserApplication=firefox.desktop Which does in no way make sense to me. If I set Firefox as default xdg-mime should not have Chrome. In fact I want Firefox. So how do I globally once and for all, across all frameworks, define Firefox as default? Best, Marius p.s.: I should probably mention, that clicking in Choqok starts Konqueror...

    Read the article

  • How to Determine the Size of MSADO Command Parameters

    - by Adam
    I am new to MS ADO and trying to understand how to set the size on command parameters as created by the command.CreateParameter (Name, Type, Direction, Size, Value) The documentation says the following: Size Optional. A Long value that specifies the maximum length for the parameter value in characters or bytes. ... If you specify a variable-length data type in the Type argument, you must either pass a Size argument or set the Size property of the Parameter object before appending it to the Parameters collection; otherwise, an error occurs. 1.) What should one pass for fixed-size parameters? Is it a "don't care"? I was a bit confused by the example found here, in which they set size to 3 for an adInteger parameter with Value set to a variant of type VT_I2 pPrmByRoyalty->Type = adInteger; pPrmByRoyalty->Size = 3; pPrmByRoyalty->Direction = adParamInput; pPrmByRoyalty->Value = vtroyal; VT_I2 implies two bytes. A tagVARIANT struct is 16 bytes. How did they land on three? I see that the enum value for adInteger happens to be three, but I suspect that is just a coincidence. So it's a bit confusing what to pass for fixed-size parameters. The team I'm working with has always passed sizeof(int) for adInteger, and it seems to work. Is that correct? Now, for "variable-length" parameters: we are instructed by the documentation to pass "the maximum length .. in characters or bytes". 2.) For adVarChar, is it sufficient to pass the max width as defined in the database? 3.) What about the Wide types (e.g. adVarWChar)? Is it characters or bytes? 4.) How about adVariant, which could contain fixed- or variable-length data? 5.) Do arrays ever come into play here? (we don't pass them as parameters, just curious) Any references or personal insights are welcome.

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >