  • RFC 1918 address on open internet?

    - by longneck
    In trying to diagnose a failover problem with my Cisco ASA 5520 firewalls, I ran a traceroute to www.btfl.com and, much to my surprise, some of the hops came back as RFC 1918 addresses. Just to be clear, this host is not behind my firewall and there is no VPN involved. I have to connect across the open internet to get there. How/why is this possible? asa# traceroute www.btfl.com Tracing the route to 157.56.176.94 1 <redacted> 2 <redacted> 3 <redacted> 4 <redacted> 5 nap-edge-04.inet.qwest.net (67.14.29.170) 0 msec 10 msec 10 msec 6 65.122.166.30 0 msec 0 msec 10 msec 7 207.46.34.23 10 msec 0 msec 10 msec 8 * * * 9 207.46.37.235 30 msec 30 msec 50 msec 10 10.22.112.221 30 msec 10.22.112.219 30 msec 10.22.112.223 30 msec 11 10.175.9.193 30 msec 30 msec 10.175.9.67 30 msec 12 100.94.68.79 40 msec 100.94.70.79 30 msec 100.94.71.73 30 msec 13 100.94.80.39 30 msec 100.94.80.205 40 msec 100.94.80.137 40 msec 14 10.215.80.2 30 msec 10.215.68.16 30 msec 10.175.244.2 30 msec 15 * * * 16 * * * 17 * * * and it does the same thing from my FiOS connection at home: C:\>tracert www.btfl.com Tracing route to www.btfl.com [157.56.176.94] over a maximum of 30 hops: 1 1 ms <1 ms <1 ms myrouter.home [192.168.1.1] 2 8 ms 7 ms 8 ms <redacted> 3 10 ms 13 ms 11 ms <redacted> 4 12 ms 10 ms 10 ms ae2-0.TPA01-BB-RTR2.verizon-gni.net [130.81.199.82] 5 16 ms 16 ms 15 ms 0.ae4.XL2.MIA19.ALTER.NET [152.63.8.117] 6 14 ms 16 ms 16 ms 0.xe-11-0-0.GW1.MIA19.ALTER.NET [152.63.85.94] 7 19 ms 16 ms 16 ms microsoft-gw.customer.alter.net [63.65.188.170] 8 27 ms 33 ms * ge-5-3-0-0.ash-64cb-1a.ntwk.msn.net [207.46.46.177] 9 * * * Request timed out. 10 44 ms 43 ms 43 ms 207.46.37.235 11 42 ms 41 ms 40 ms 10.22.112.225 12 42 ms 43 ms 43 ms 10.175.9.1 13 42 ms 41 ms 42 ms 100.94.68.79 14 40 ms 40 ms 41 ms 100.94.80.193 15 * * * Request timed out.

    Read the article

  • MS Access group development

    - by Hubidubi
    We are planning to redesign quite a huge MS Access application. Is there any way to work concurently on the same application or is it possible to merge two seperate instance of the same file (not the data, but the forms and code). Now Access contains the data, but in the future version MySQL will host the data and Access will be only the frontend (via ODBC)

    Read the article

  • Record and Play your WebLogic Console Tasks Like a DVR

    - by james.bayer
    Automation using WebLogic Scripting Tool Today on the Oracle internal mailing list for WebLogic Server questions someone asked how to automate the configuration of the thread model for WebLogic Server and they were having trouble with the jython scripting syntax.  I’ve previously written about this feature called Work Managers and the associated constraints.  However, I did not show how to automate the process of configuring this without the console using WebLogic Scripting Tool – the jython scripting automation environment abbreviated as WLST.  I’ve written some very basic introductions to WLST before and there is also an Oracle By Example on the subject, but this is a bit more advanced.  Fear not because there is a really easy-to-use feature of the WLS console that lets you “Record” user actions just like a DVR.  Using these recordings of the web-based console, you can easily create a script even if you are unfamiliar with the WLST syntax and API.  I’m a big fan of both DVR’s and automation as can be evidenced with this old Halloween picture taken during simpler times.  Obviously the Cast Away and The Big Labowski references show some age.  I was a big Tivo fan-boy back in the day and I still think it’s the best DVR. I strongly believe that WebLogic Scripting Tool (WLST) is an absolutely essential tool for automating administration tasks in anything beyond a development environment.  Even in development environments you can make a case that it makes sense to start the automation for environments downstream.  I promise you that once you start using it for any tasks that you do even semi-regularly, you won’t go back to clicking through the console.  It’s simply so much more efficient and less error-prone to run a script. Let’s say you need to create a Work Manager and MaxThreadsConstraint – the easy way to do it is configure it in the WLS console first while capturing the commands with a recording.  See the images for the simple steps – click to enlarge. Record Console Configurations to a File Review the Recordings and Make Slight Modifications In order to make the recorded .py file directly callable as a stand-alone script I added calls to the connect() and edit() functions at the beginning and calls to disconnect() and exit() at the end – otherwise the main section of the script was provided by the console recording.  Below is the resulting file I saved as d:/temp/wm.py connect('weblogic','welcome1', 't3://localhost:7001') edit() startEdit()   cd('/SelfTuning/wl_server') cmo.createMaxThreadsConstraint('MaxThreadsConstraint-0')   cd('/SelfTuning/wl_server/MaxThreadsConstraints/MaxThreadsConstraint-0') set('Targets',jarray.array([ObjectName('com.bea:Name=examplesServer,Type=Server')], ObjectName)) cmo.setCount(5) cmo.unSet('ConnectionPoolName')   cd('/SelfTuning/wl_server') cmo.createWorkManager('WorkManager-0') cd('/SelfTuning/wl_server/WorkManagers/WorkManager-0') set('Targets',jarray.array([ObjectName('com.bea:Name=examplesServer,Type=Server')], ObjectName))   cmo.setMaxThreadsConstraint(getMBean('/SelfTuning/wl_server/MaxThreadsConstraints/MaxThreadsConstraint-0')) cmo.setIgnoreStuckThreads(false)   activate() disconnect() exit() Run the Script If you want to test it be sure to delete the Work Manager and MaxThreadConstraint that you had previously created in the console.  Do something like the following - set up the environment and tell WLST to execute the script which happens in the first 2 lines, the rest doesn’t require any user input: D:\Oracle\wls11g\wlserver_10.3\samples\domains\wl_server\bin>setDomainEnv.cmd D:\Oracle\wls11g\wlserver_10.3\samples\domains\wl_server>java weblogic.WLST d:\temp\wm.py   Initializing WebLogic Scripting Tool (WLST) ...   Welcome to WebLogic Server Administration Scripting Shell   Type help() for help on available commands   Connecting to t3://localhost:7001 with userid weblogic ... Successfully connected to Admin Server 'examplesServer' that belongs to domain 'wl_server'.   Warning: An insecure protocol was used to connect to the server. To ensure on-the-wire security, the SSL port or Admin port should be used instead.   Location changed to edit tree. This is a writable tree with DomainMBean as the root. To make changes you will need to start an edit session via startEdit().   For more help, use help(edit)   Starting an edit session ... Started edit session, please be sure to save and activate your changes once you are done. Activating all your changes, this may take a while ... The edit lock associated with this edit session is released once the activation is completed. Activation completed Disconnected from weblogic server: examplesServer     Exiting WebLogic Scripting Tool.   Now if you go back and look in the console the changes have been made and we now have a compete script.  Of course there is a full MBean reference and you can learn the nuances of jython and WLST, but why not the WLS console do most of the work for you!  Happy scripting.

    Read the article

  • MS Access Draw line around detail section that can grow

    - by LanguaFlash
    This really shouldn't be hard, I just can't figure out how to do it. I am making a proposal report that needs to have a border around it. The problem is to get the vertical lines on the side. I can't figure out how to get a line to grow and shrink based on the height of the detail section. I have used Crystal reports and sure wish Microsoft would learn a few things in regards to MS Access report writing! I am very comfortable with VBA so have no fears there. :-) Thanks, Jeff

    Read the article

  • Splitting MS Access Database - Front End Part Location

    - by kristof
    One of the best practices as specified by Microsoft for Access Development is splitting Access application into 2 parts; Front End that hold all the object except tables and the Back End that holds the tables. The msdn page links there to the article Splitting Microsoft Access Databases to Improve Performance and Simplify Maintainability that describes the process in details. It is recommended that in multi user environment the Back End is stored on the server/shared folder while the Front End is distributed to each user. That implies that each time there are any changes made to the front end they need to be deployed to every user machine. My question is: Assuming that the users themselves do not have rights to modify the Front End part of the application what would be the drawbacks/dangers of leaving this on the server as well next to the Back End copy? I can see the performance issues here, but are there any dangers here like possible corruptions etc? Thank you EDIT Just to clarify, the scenario specified in question assumes one Front End stored on the server and shared by users. I understand that the recommendation is to have FE deployed to each user machine, but my question is more about what are the dangers if that is not done. E.g. when you are given an existing solution that uses the approach of both FE and BE on the server. Assuming the the performance is acceptable and the customer is reluctant to change the approach would you still push the change? And why exactly? For example the danger of possible data corruption would definitely be the strong enough argument, but is that the case? It is a part of follow up of my previous question From SQL Server to MS Access 2007

    Read the article

  • Traceroute comparison and statistics

    - by ben-casey
    I have a number of traceroutes that i need to compare against each other but i dont know the best way to do it, ive been told that hash maps are a good technique but i dont know how to implement them on my code. so far i have: FileInputStream fstream = new FileInputStream("traceroute.log"); // Get the object of DataInputStream DataInputStream in = new DataInputStream(fstream); BufferedReader br = new BufferedReader(new InputStreamReader(in)); String strLine; // reads lines in while ((strLine = br.readLine()) != null) { System.out.println(strLine); } and the output looks like this: Wed Mar 31 01:00:03 BST 2010 traceroute to www.bbc.co.uk (212.58.251.195), 30 hops max, 40 byte packets 1 139.222.0.1 (139.222.0.1) 0.873 ms 1.074 ms 1.162 ms 2 core-from-cmp.uea.ac.uk (10.0.0.1) 0.312 ms 0.350 ms 0.463 ms 3 ueaha1btm-from-uea1 (172.16.0.34) 0.791 ms 0.772 ms 1.238 ms 4 bound-from-ueahatop.uea.ac.uk (193.62.92.71) 5.094 ms 4.451 ms 4.441 ms 5 gi0-3.norw-rbr1.eastnet.ja.net (193.60.0.21) 4.426 ms 5.014 ms 4.389 ms 6 gi3-0-2.chel-rbr1.eastnet.ja.net (193.63.107.114) 6.055 ms 6.039 ms * 7 lond-sbr1.ja.net (146.97.40.45) 6.994 ms 7.493 ms 7.457 ms 8 so-6-0-0.lond-sbr4.ja.net (146.97.33.154) 8.206 ms 8.187 ms 8.234 ms 9 po1.lond-ban4.ja.net (146.97.35.110) 8.673 ms 6.294 ms 7.668 ms 10 bbc.lond-sbr4.ja.net (193.62.157.178) 6.303 ms 8.118 ms 8.107 ms 11 212.58.238.153 (212.58.238.153) 6.245 ms 8.066 ms 6.541 ms 12 212.58.239.62 (212.58.239.62) 7.023 ms 8.419 ms 7.068 ms what i need to do is compare this trace against another one just like it and look for the changes and time differences etc, then print a stats page.

    Read the article

  • MS Access 2003 - ordering the string values for a chart not alphabetical

    - by Justin
    Here is a silly question. Lets say I have a query that produces for a list box, and it produces values for three stores Store A 18 Store B 32 Store C 54 Now if I ORDER BY in the sql statement the only thing it will do is descending or ascending alphabetically but I want a certain order (only because THEY WANT A CERTAIN ORDER) .....so is there a way for me to add something to the SQL to get Store B Store C Store A i.e. basically row by row what i want. thanks!

    Read the article

  • MS Access 2003 - Embedded Excel Spreadsheet on Access form

    - by Justin
    lets say I have an embedded Excel Spreadsheet on a Microsoft Access form. I call the object frame ExcelFrame and I add a text box on the form called txtA1 and I add a button on the form called cmdInsert I want to type "Hello World" into the text box, click the button and have it appear in the A1 cell on that spreadsheet. What VBA do I use to accomplish this? Thanks

    Read the article

  • MS Access 2003 - Message Box: How can I answer "ok" automatically through code

    - by Justin
    So a couple silly questions: If I include this in some event: MsgBox " ", vbOkOnly, "This little message box" could I then with some more code turn around and 'click the ok button. So that basically the message boox automatically pops up, and then automatically goes away? I know its silly because you want to know, why do you want the message box then..... well a) i just want to know if you can do that, and what would be the command b) i have some basic shapes (shape objects) that are made visible when the message box appears. But without having the message box there, there is no temporary disruption of code while waiting for the button to be clicked, and therefor those pretty image objects being made visible does take effect on the the form. So I really do not need the message box, just the temp disruption that shows the objects. Thanks!

    Read the article

  • 6to4 tunnel: cannot ping6 to ipv6.google.com?

    - by quanta
    Hi folks, Follow the Setup of 6to4 tunnel guide, I want to test ipv6 connectivity, but I cannot ping6 to ipv6.google.com. Details below: # traceroute 192.88.99.1 traceroute to 192.88.99.1 (192.88.99.1), 30 hops max, 40 byte packets 1 static.vdc.vn (123.30.53.1) 1.514 ms 2.622 ms 3.760 ms 2 static.vdc.vn (123.30.63.117) 0.608 ms 0.696 ms 0.735 ms 3 static.vdc.vn (123.30.63.101) 0.474 ms 0.477 ms 0.506 ms 4 203.162.231.214 (203.162.231.214) 11.327 ms 11.320 ms 11.312 ms 5 static.vdc.vn (222.255.165.34) 11.546 ms 11.684 ms 11.768 ms 6 203.162.217.26 (203.162.217.26) 42.460 ms 42.424 ms 42.401 ms 7 218.188.104.173 (218.188.104.173) 42.489 ms 42.462 ms 42.415 ms 8 218.189.5.10 (218.189.5.10) 42.613 ms 218.189.5.42 (218.189.5.42) 42.273 ms 42.300 ms 9 d1-26-224-143-118-on-nets.com (118.143.224.26) 205.752 ms d1-18-224-143-118-on-nets.com (118.143.224.18) 207.130 ms d1-14-224-143-118-on-nets.com (118.143.224.14) 206.970 ms 10 218.189.5.150 (218.189.5.150) 207.456 ms 206.349 ms 206.941 ms 11 * * * 12 10gigabitethernet2-1.core1.lax1.he.net (72.52.92.121) 214.087 ms 214.426 ms 214.818 ms 13 192.88.99.1 (192.88.99.1) 207.215 ms 199.270 ms 209.391 ms # ifconfig tun6to4 tun6to4 Link encap:IPv6-in-IPv4 inet6 addr: 2002:x:x::/16 Scope:Global inet6 addr: ::x.x.x.x/128 Scope:Compat UP RUNNING NOARP MTU:1480 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:11 dropped:0 overruns:0 carrier:11 collisions:0 txqueuelen:0 RX bytes:0 (0.0 b) TX bytes:0 (0.0 b) # iptunnel sit0: ipv6/ip remote any local any ttl 64 nopmtudisc tun6to4: ipv6/ip remote any local x.x.x.x ttl 64 # ip -6 route show ::/96 via :: dev tun6to4 metric 256 expires 21332777sec mtu 1480 advmss 1420 hoplimit 4294967295 2002::/16 dev tun6to4 metric 256 expires 21332794sec mtu 1480 advmss 1420 hoplimit 4294967295 fe80::/64 dev eth0 metric 256 expires 15674592sec mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev eth1 metric 256 expires 15674597sec mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev tun6to4 metric 256 expires 21332794sec mtu 1480 advmss 1420 hoplimit 4294967295 default via ::192.88.99.1 dev tun6to4 metric 1 expires 21332861sec mtu 1480 advmss 1420 hoplimit 4294967295 # ping6 -n -c 4 ipv6.google.com PING ipv6.google.com(2404:6800:8005::68) 56 data bytes From 2002:x:x:: icmp_seq=0 Destination unreachable: Address unreachable From 2002:x:x:: icmp_seq=1 Destination unreachable: Address unreachable From 2002:x:x:: icmp_seq=2 Destination unreachable: Address unreachable From 2002:x:x:: icmp_seq=3 Destination unreachable: Address unreachable --- ipv6.google.com ping statistics --- 4 packets transmitted, 0 received, +4 errors, 100% packet loss, time 2999ms What is my problem? Thanks,

    Read the article

  • Can't change data type on MS Access 2007

    - by khalidfazeli
    Hi All, I have a huge database (800MB) which consists of a field called 'Date Last Modified' at the moment this field is entered as a text data type but need to change it to a Date/Time field to carry out some queries. I have another exact same database but with only 35MB of data inside it and when I change the data type it works fine, but when I try to change data type on big database it gives me an error: Micorosoft Office Access can't change the data type. There isn't enough disk space or memory After doing some research some sites mentioned of changing the registry file (MaxLocksPerFile) tried that as well, but no luck :-( Can anyone help please?

    Read the article

  • Cannot access a very specific site from my router

    - by DJDarkViper
    This is a problem for me because this site is important to me. It's MY website. And sadly my email is hosted on my site (which I cant access either) When I try to access my website when connected to my Linksys E3000 router, these days it simply just doesn't go through. When I ping it, its all Request Timed Out, and when I tracert C:\Users\Kyle>tracert blackjaguarstudios.com Tracing route to blackjaguarstudios.com [199.188.204.228] over a maximum of 30 hops: 1 <1 ms <1 ms <1 ms CISCO26565 [192.168.1.1] 2 16 ms 15 ms 11 ms 11.4.64.1 3 11 ms 9 ms 11 ms rd1cs-ge1-2-1.ok.shawcable.net [64.59.169.2] 4 20 ms 21 ms 22 ms 66.163.76.98 5 37 ms 36 ms 35 ms rc1nr-tge0-9-2-0.wp.shawcable.net [66.163.77.54] 6 112 ms 84 ms 85 ms rc2ch-pos9-0.il.shawcable.net [66.163.76.174] 7 86 ms 89 ms 90 ms rc4as-ge12-0-0.vx.shawcable.net [66.163.64.46] 8 90 ms 84 ms 85 ms eqix.xe-3-3-0.cr2.iad1.us.nlayer.net [206.223.115.61] 9 97 ms 97 ms 99 ms xe-3-3-0.cr1.atl1.us.nlayer.net [69.22.142.105] 10 128 ms 128 ms 126 ms ae1-40g.ar1.atl1.us.nlayer.net [69.31.135.130] 11 101 ms 97 ms 96 ms as16626.xe-2-0-5-102.ar1.atl1.us.nlayer.net [69.31.135.46] 12 100 ms 97 ms 197 ms 6509-sc1.abstractdns.com [207.210.114.166] 13 * * * Request timed out. 14 * * * Request timed out. 15 * * * Request timed out. 16 * * * Request timed out. 17 * * * Request timed out. 18 * * * Request timed out. 19 * * * Request timed out. 20 * * * Request timed out. 21 * * * Request timed out. 22 * * * Request timed out. 23 * * * Request timed out. 24 * * * Request timed out. 25 * * * Request timed out. 26 * * * Request timed out. 27 * * * Request timed out. 28 * * * Request timed out. 29 * * * Request timed out. 30 * * * Request timed out. Trace complete. C:\Users\Kyle> SHAW Cable being my ISP. Figuring this was all something to do with some setting I made on the router, I reset the thing back to factory defaults. Nope. So I'm at a bit of a loss what to do here, as NO device (Computers, Laptops, Tablets, Phones, PS3/ 360, etc) can access my site or its features, so it's not just my computer either. But every other site is just fine. When I connect to my neighbors router, the site comes up just fine. And shes with SHAW as well. What should I do?!

    Read the article

  • MS Access form_current() firing multiple times

    - by Eric G
    I have a form with two subforms (on separate tab pages). It's an MDB project in Access 2003. When it initially opens, Form_Current on the active subform fires once, as it should. But when you move to another record (ie. from the main form), it fires Form_Current on the active subform 4 times. Then subsequent record-moves result in Form_Current firing 2 times. This is a pain, because the subforms have a lot of fields that get moved and/or hidden and so it jumps around for every Form_Current, not to mention being slow. I am opening the form with a filter via DoCmd.OpenForm (actually it sends the filter in via OpenArgs). FilterOn is only set once, in Form_Open on the main form, never in the subforms. Form_Current is not called explicitly anywhere else in the code. When I look at the call stack when Form_Current fires moving the first time, it looks like: my_subform.Form_Current [<Debug Window>] my_subform.Form_Current So it seems like something in Form_Current is triggering another Form_Current event. But only on the first record move. The code in Form_Current is somewhat complex, involving custom classes and event callbacks, but generally does not touch the table data. The only thing I can think might be triggering a Form_Current is that it checks OldValue on form controls - could this be causing it? Or anything else come to mind? Thanks. Eric

    Read the article

  • Create Directory for records in MS Access 2007

    - by glinch
    Hi there, Is it possible to create a directory folder for individual records in Access 2007. For example tblUser ID firstName surName When adding a record, would create a folder C:\userdatabase\Surname,firstName,ID Could see this being useful in situations for example where a large amount of images/files would need to be associated with a record. Access would create and link to a directory for each record. Thanks in advance for any advice Noel

    Read the article

  • MS-Access 2007 Runtime SendObject Crash

    - by ccraiff
    I have programmed an Access Database program using Access 2007. I have a button that points to the event: DoCmd.SendObject acSendReport to have it email a PDF report (acFormatPDF). Everything works fine in the normal Access 2007 program, but when a user opens the program with Access 2007 Runtime, when clicking on this button it goes through the normal steps (notifying Outlook, waiting for Allow/Deny clearance), and then after you click Allow, the program crashes with a Runtime Error. Does anybody know what is going on here? Is this a normal error with Access Runtime? I have tried other file formats (RTF and XLS) instead of PDF, but it seems to be the SendObject command that is crashing the Runtime Environment? Clarification: Access Runtime does not output an error code upon this crash. Just a window stating a "runtime error has occurred".

    Read the article

  • MS Access: Order of Events in event ApplyFilter (ADP Project)

    - by Jose Valdes
    I'm having problems with the execution of ServerFilterByForm in Access 2003 When I apply the entered filter it returns the requested data but after it appear on screen (Form) it disappears. Don't know why this is happening Does anyone had the same problem? How can it be solved? Heris is part of the code Private Sub Form_ApplyFilter(Cancel As Integer, ApplyType As Integer) Dim stSql As String If Len(ServerFilter) > 0 Then stSql = "SELECT * FROM v_InitialReviewQuery " & _ " WHERE " + ServerFilter & _ " ORDER BY acctnumber" Else stSql = "SELECT top 1 * FROM v_InitialReviewQuery ORDER BY acctnumber" End If Me.RecordSource = stSql End Sub

    Read the article

  • MS access refusing to combine two tables?

    - by Mahmoud
    hey everyone i have an access 2007 database where i have 2 tables one is exp_cash and exp_cheque each are link to exp_cat, where exp_cat contains categories list where exp_cash contains id,cat_id,exp_date,exp_amount,exp_note same thing in exp_cheque where when i came to combine them nothing in result unless i remove the cat_name from my query i used a simple query which is SELECT DISTINCT exp_cat.cat_name, exp_cash.exp_amount, exp_cheque.exp_amount FROM (exp_cat INNER JOIN exp_cash ON exp_cat.ID = exp_cash.exp_cat_id) INNER JOIN exp_cheque ON exp_cat.ID = exp_cheque.exp_cat_id;

    Read the article

  • MS Access: index optimisation

    - by Patrick Honorez
    Let's say we have a [Valuations] table containing several values per date and per fund: -FundId -ValDate -Value1 -Value2... The Primary key is obviously FundId+ValDate. I have also indexed the ValDate field since I often query for values on a specific date. My question is: should I also create a specific index for the FundId, or is MsAccess clever enough to use the Primary key when querying on a specific FundId ?

    Read the article

  • Idera SQL Doctor 3.0 and MS SQL Changes

    New features worth mentioning in SQL doctor 3.0 begin with a new server dashboard that not only gives a comprehensive overview of a SQL Server instance's current health, but also several key details to help database administrators. Some of the details include recommendations on how to optimize server configuration, how to fix certain security issues, and how to get rid of performance bottlenecks. The latest version of SQL doctor also supplies users with key server information. The status of system parameters known to affect SQL Server performance, such as processes, disk partitions, cache, m...

    Read the article

  • MS SQL Sever 2012 Launch, New Idera Release

    Idera, a Microsoft Managed Partner and Houston-based provider of tools that specialize in the management and administration of Microsoft SQL Server, PowerShell, and SharePoint, recently announced the release of Idera SQL safe 7.0. The latest version of the SQL Server backup and recovery solution comes equipped with various improvements which are highlighted by the company's innovative Instant Restore technology. The release adds to Idera's impressive stable of products that has earned it over 10,000 customers across the globe since its inception. The Instant Restore technology integrated in ...

    Read the article

  • Win7 playback of dvr-ms files stutters

    - by Jim Lynn
    I've just had to install Windows 7 on my Media Center machine because my Vista installation had a faulty drive. I've got the latest drivers that I can find - Intel 945GM integrated Graphics, Realtek audio drivers. Things are working OK with one exception. Playback of old recordings, from dvr-ms format files, is choppy. The picture freezes for a fraction of a second, then quickly catches up. The sound is uninterrupted and doesn't pause. These freezes happen once every 5 seconds or so. It's very regular. Playback of Live TV from the digital tuner is perfectly smooth. DVD playback is perfectly smooth. As an experiment, I used the MPEG editing package VideoReDo to create a small test file in three different formats. This program takes the raw MPEG streams and repackages them into the desired container. I took the same clip and created three files in three formats: dvr-ms (Microsoft's old recorded TV format); mpg (standard MPEG); and ts (raw MPEG transport stream of the kind often produced by PVRs). When these three files are played back under Windows 7, the mpg and ts files play smoothly, but the dvr-ms file stutters. The last piece of data I have is that two other Windows 7 machines can play back dvr-ms files smoothly with no stuttering. One is a netbook, with less grunt than the media centre. So there must be something specific about my Media Center machine that's causing the problem. Does anyone have any idea where I can look now? I don't know much about AV software, codecs, filter graphs etc. but I suspect that's where the problem lies. Rendering the video isn't the problem, but extracting the streams is. How would I go about diagnosing the problem? Edited to add: I just used the GraphStudio tool to look at the filter graph on the offending PC. The filter graph it uses by default for dvr-ms looks identical to the other machines, and, interestingly, when I play the files using GraphStudio they run smoothly. Under Windows Media Player and Windows Media Center they stutter. I'd like to see the filter graph for WMP but GraphStudio won't show it. It looks like WMP and WMC are using a different decoding path to GraphStudio. Edited again to add: Today I purchased a new HDTV. The same Media Center driving the TV at 1080p is now playing back the old Recorded TV files smoothly, without stuttering. So whatever the cause of the original problem, using a different resolution seems to have removed the problem. It might also explain why nobody else has had this problem. I doubt many people use Media Centre with a 14in portable TV.

    Read the article