Search Results

Search found 6967 results on 279 pages for 'multi channel'.

Page 3/279 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Fiber Channel Loop vs Point to Point

    - by RandomInsano
    So, I'm playing with a couple of QLogic QLA2340s connected directly together. I've got options here to either have them act as a loop, or in point to point mode. What's the difference if I'm only going to have two machines connected together? Is point-to-point more efficient? The firmware has an option to prefer loop, then fall back to p2p. Anyone have any idea if there are performance benefits or drawbacks? It's pretty hard to find that information.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • Concurrent WCF calls via shared channel

    - by Kent Boogaart
    I have a web tier that forwards calls onto an application tier. The web tier uses a shared, cached channel to do so. The application tier services in question are stateless and have concurrency enabled. But they are not being called concurrently. If I alter the web tier to create a new channel on every call, then I do get concurrent calls onto the application tier. But I wanted to avoid that cost since it is functionally unnecessary for my scenario. I have no session state, and nor do I need to re-authenticate the caller each time. I understand that the creation of the channel factory is far more expensive than than the creation of the channels, but it is still a cost I'd like to avoid if possible. I found this article on MSDN that states: While channels and clients created by the channels are thread-safe, they might not support writing more than one message to the wire concurrently. If you are sending large messages, particularly if streaming, the send operation might block waiting for another send to complete. Firstly, I'm not sending large messages (just a lot of small ones since I'm doing load testing) but am still seeing the blocking behavior. Secondly, this is rather open-ended and unhelpful documentation. It says they "might not" support writing more than one message but doesn't explain the scenarios under which they would support concurrent messages. Can anyone shed some light on this?

    Read the article

  • Best practise for Progress Bar in Python's PyGTK

    - by Matthew Walker
    I would like to get feedback on others' opinions of best practice for how to implement a progress bar in Python's PyGTK. The work that the progress bar was to represent was very significant computationally. Therefore, I wanted the work to be done in a separate process (thus giving the operating system the possibility to run it on a different core). I wanted to be able to start the work, and then continue to use the GUI for other tasks while waiting for the results. I have seen many people asking this question indirectly, but I have not seen any concrete expert advice. I hope that by asking this question we will see a community's combined expertise. I have read the FAQ and I hope that "Programmers" is the right place to ask.

    Read the article

  • Múltiples clientes en el mismo Oracle UCM

    - by [email protected]
    Estamos muy activos con la implantación de plataformas ECM que den servicio a múltiples clientes. Consiguiendo 2 objetivos muy importantes:El cliente final puede pagar al proveedor por una plataformas ECM como servicio (SaaS). Y, lógicamente, se ahorra en complejidad y gastos de infraestructura, administración, formación, almacenamiento, etc...Hemos estado explicando estos días el modelo Master-Proxy de Oracle UCM con el que podemos implantar este tipo de plataformas. No siempre será la solución más adecuada porque a veces vamos a querer disponer de plataformas compartidas, pero con clientes completamente aislados. Siempre, la consola de migración nos permite exportar e importar componentes, metadatos, contenidos, workflows, etc... para que elijamos el modelo más adecuado para cada caso.Pero, ¿Cómo funciona?. Podéis ver en la imágen que se basa en la instalación de varias instancias de UCM y configurarlas de forma que varias de ellas se comporten como "Master" (digo varias para conseguir alta disponibilidad), y el resto se comporten como "Proxy" (también varias instancias de UCM pueden comportarse como un mismo "Proxy" permitiendo balancear la carga en función de que cada cliente requiera más o menos rendimiento). Esta configuración (que vemos en la imágen adjunta), nos permite:Delegar la gestión de usuarios de cada cliente. Los usuarios del Master podrán acceder a todos los Proxies, pero los usuarios de cada proxy sólo acceden a su repositorio.Delegar funcionalidad y componentes. Es posible configurar diferentes funcionalidades en cada proxy de forma que algunos servidores estén especializados en Web Content Management, otros en Document Management (por ejemplo).Diferentes modelos de metadatos. Podemos modelar unos tipos documentales generales para toda la plataforma y otros particulares diferentes en cada UCM "Proxy".Conseguir una centralización de búsquedas y acceso a repositorios de documentación con diferentes juegos de caracteres. Un UCM Master puede centralizar la búsqueda en UCM's proxy que alberguen documentación en diferentes juegos de caracteres (por ejemplo un UCM para documentación de idiomas "Western European" (inglés, español, francés, alemán,...) y otro UCM proxy bajo juego de caracteres "Asian" (japones, coreano, chino,...).Fuentes:Toda la información detallada se encuentra en la documentación de Oracle UCM, aquí:http://download.oracle.com/docs/cd/E10316_01/ouc.htmY en concreto, lo relativo a plataformas, en el documento "Planning and Implementation Guide", aquí:plan_implement_guide_10en.pdf

    Read the article

  • Creating blur with an alpha channel, incorrect inclusion of black

    - by edA-qa mort-ora-y
    I'm trying to do a blur on a texture with an alpha channel. Using a typical approach (two-pass, gaussian weighting) I end up with a very dark blur. The reason is because the blurring does not properly account for the alpha channel. It happily blurs in the invisible part of the image, whcih happens to be black, and thus results in a very dark blur. Is there a technique to blur that properly accounts for the alpha channel?

    Read the article

  • OSB 11g & SAP – Single Channel/Program ID for Multiple IDOCs

    - by Shub Lahiri, A-Team
    Background This note is a supplement to the blog entry, SOA 11g & SAP – Single Channel/Program ID for Multiple IDOCs by Greg Mally. Greg has shown how a single SOA Suite composite can be used with iWay Adapters to receive multiple IDOC types via a single channel in the adapter, corresponding to a single programID on the SAP system. We will try to address the same requirements within the OSB framework here. Project Built - Design Time The basic build of an OSB project with iWay SAP Adapter, as seen in another entry in this blog, consists of working in OSB Design console and Application Explorer. OSB Design Time - Part 1 We will create a placeholder project first in OSB with a proper directory structure, so that we can export the WSDL, XSD and the JCA binding information from Application Explorer directly into this project. Application Explorer - iWay Design Time Tool Receiving IDOCs is classified as an inbound event within Application Explorer. For setting up events, a channel is first defined (e.g. iDoc_Channel) using the same PROGRAMID (RFC destination), as defined within SAP for the OSB server. Next, the same channel is used to export the JCA Inbound Event artifacts for the candidate IDOC, e.g. DEBMAS06 directly to the pre-created OSB project. Note that the validation for schema has been turned off. As a result, this will allow the adapter, at runtime, to use a single channel to receive multiple IDOC types from SAP and pass them on to the OSB runtime engine without any validation. In other words, we do not have to repeat the above step for each IDOC type. OSB Design Time - Part 2 Create 2 simple XML based Business Services to write to a file, e.g.  SAP_DEBMAS_File and SAP_MATMAS_File. Next, generate a Proxy Service using the JCA binding file exported from Application Explorer in the previous section. In the generated proxy service, edit the message flow and add a route node. Add a routing table in the route node with the following routing function. fn:local-name-from-QName(fn:node-name($body/*[1])) This function takes advantage of the fact that the XML payload at runtime, after translation by adapter, has the IDOC type as the top element. With the routing function in place, build the routing table to add 2 branches to route the IDOCs to the appropriate Business Service for writing the XML payload to files in separate directories. This completes the build of the OSB project. Testing - Run-Time After deployment and activation, the SAP adapter will wait to receive multiple types of IDOCs sent from the SAP system using a single channel. Upon receipt of the IDOCs, the OSB project will route them appropriately to save the corresponding XML payloads for different IDOC types in different directories.

    Read the article

  • Sound Channel map incorrect on an ION 330 ASRock

    - by math
    I have a ION 330 ASRock just updated on Precise and the sound channel mapping is incorrect. Channel map is set as follow: Front Left = Front left Center = Rear Left Front Right = Font Right Rear Right = LFE Rear Left = Center LFE = Rear Right I am testing the sound channel using speaker-test -c 2 -t wav Can some one tell me how I can remap easily? I have tried several possible changes to /etc/pulse/defaut.pa unsuccessfully.

    Read the article

  • What threading pratice is good 90% of the time?

    - by acidzombie24
    Since my SO thread was closed i guess i can ask it here. What practice or practices are good 90% of the time when working with threading with multiple cores? Personally all i have done was share immutable classes and pass (copy) data to a queue to the destine thread. Note: This is for research and when i say 90% of the time i dont mean it is allowed to fail 10% of the time (thats ridiculous!) i mean 90% it is a good solution while the other 10% it is not so desirable due to implementation or efficiently reasons (or plainly another technique fits the problem domain a lot better).

    Read the article

  • How to change the volume of left channel using pulseaudio

    - by user2622247
    I am recording the video using logitech camera and bluetooth microphone. Logitech can used for recording both audio and video. When I turn on bluetooth microphone in the middle of recording, it is replacing the logitech audio channel due to this we are getting the bluetooth audio from the left channel. But when I turn off the bluetooth then I get the logitech audio on left channel but the volume is very low and also getting the some noise. I am using PulseAudio and ffmpeg for recording purpose. So how can I increase / change the volume of left channel during runtime?

    Read the article

  • Etiquette when asking questions in an IRC channel

    - by Zarkonnen
    Many larger OSS projects maintain IRC channels to discuss their usage or development. When I get stuck on using a project, having tried and failed to find information on the web, one of the ways I try to figure out what to do is to go into the IRC channel and ask. But my questions are invariably completely ignored by the people in the channel. If there was silence when I entered, there will still be silence. If there is an ongoing conversation, it carries on unperturbed. I leave the channel open for a few hours, hoping that maybe someone will eventually engage me, but nothing happens. So I worry that I'm being rude in some way I don't understand, or breaking some unspoken rule and being ignored for it. I try to make my questions polite, to the point, and grammatical, and try to indicate that I've tried the obvious solutions and why they didn't work. I understand that I'm obviously a complete stranger to the people on the channel, but I'm not sure how to fix this. Should I just lurk in the channel, saying nothing, for a week? That seems absurd too. A typical message I send might be "Hello all - I've been trying to get Foo to work, but I keep on getting a BarException. I tried resetting the Quux, but this doesn't seem to do anything. Does anyone have a suggestion on what I could try?"

    Read the article

  • Auszeichnung für Oracle beim Channel Marketing Award 2010: IT-Security Kampagne "Keine Aufregung" belegt 2. Platz

    - by A&C Redaktion
    Am 18. November wurde in Augsburg der Channel Marketing Award 2010 verliehen. Gesucht wurden die besten Kampagnen der IT-Branche, mit denen wirtschaftlich und kreativ herausragende Marketing-Aktivitäten rund um das Partner Business umgesetzt wurden. In der Kategorie With/Through Partner hat Oracle mit der IT-Security Kampagne www.keine-aufregung.de hinter Xerox den 2. Platz belegt! Damit verwies „Keine Aufregung", durchgeführt von Bozana Pistorius im Januar 2010, Kampagnen von IBM, Corel und E-Plus auf die Plätze. Bilder der Kampagnen sind hier zu finden. Die Berichterstattung zum CMA Award gibt es online bei IT-Business inklusive Video und Bildergalerie.   V.l.n.r.: Alexander Woelke (Woelke von der Brüggen), Sarah Olbrich (Woelke von der Brüggen), Bozana Pistorius (Oracle), Claudine Petit (Cloudbridge Consulting) und Werner Nieberle (Vogel IT Medien)

    Read the article

  • Does HDC use alpha channel?

    - by Crend King
    Hello. Is there a way I can determine if an HDC uses alpha channel? I read Question 333559 and Question 685684, but their questions are about BITMAP. Apparently, some HDC has alpha channel (though they may not use it. Call this "Type 1") while others do not ("Type 2"). I know this by doing the following: Given a HDC, Create a compatible DC, and create a DIB section. Select the created HBITMAP into the compatible DC. BitBlt the source HDC to the compatible DC. Now examine the DIB section bits. For type 2 HDC, after every 3 bytes there is a byte always 0 (like 255 255 255 0); for type 1, these bytes are usualy 255 (like 250 240 230 255). To avoid false positive, I memset the bits to all 0x80 prior to the calls. Use GetDIBits directly on the source HDC, specify the HBITMAP as GetCurrentObject(hdc, OBJ_BITMAP). For both types of HDC, the 4th bytes are always 0. Change the DC bitmap by calling ExtTextOut. For type 2, ExtTextOut always set the 4th bytes to 0. For type 1, ExtTextOut always leave them untouched. I also noticed that the source HDC that are created by APIs (CreateCompatibleDC(), BeginPaint() ...) are always type 2. Type 1 HDC are from standard controls (like menu text). Even the HDC I CreateCompatibleDC from a type 1 becomes a type 2. So, on one hand, I'm frustrated that Microsoft does not provide equal information to developers (another example may be that you cannot know the direction of a HBITMAP after it is created), on the other hand, I'm still wondering is there a way to distinguish these HDC. Thanks for help.

    Read the article

  • Dlink DWA-556 Access point fails to start on 2.6.35-25 while 2.6.35-24 works. How can I do this with >2.6.35-24?

    - by Azendale
    I'm using hostapd to run an access point with a Dlink DWA-556 wireless N card. However, I can no longer get it to start when I use kernels greater than 2.6.35-24. Here's a log where I ran the uname -a&&hostapd -c <configfile> on the different kernel versions. Linux erikbandersen 2.6.35-24-generic #42-Ubuntu SMP Thu Dec 2 02:41:37 UTC 2010 x86_64 GNU/Linux Configuration file: hostapd.conf ctrl_interface_group=0 Opening raw packet socket for ifindex 248 BSS count 1, BSSID mask ff:ff:ff:ff:ff:ff (0 bits) SIOCGIWRANGE: WE(compiled)=22 WE(source)=21 enc_capa=0xf nl80211: Added 802.11b mode based on 802.11g information HT40: control channel: 2 secondary channel: 6 RATE[0] rate=10 flags=0x2 RATE[1] rate=20 flags=0x6 RATE[2] rate=55 flags=0x6 RATE[3] rate=110 flags=0x6 RATE[4] rate=60 flags=0x0 RATE[5] rate=90 flags=0x0 RATE[6] rate=120 flags=0x0 RATE[7] rate=180 flags=0x0 RATE[8] rate=240 flags=0x0 RATE[9] rate=360 flags=0x0 RATE[10] rate=480 flags=0x0 RATE[11] rate=540 flags=0x0 Passive scanning not supported Mode: IEEE 802.11g Channel: 2 Frequency: 2417 MHz Flushing old station entries Deauthenticate all stations Using interface wlan1 with hwaddr 1c:bd:b9:d5:e8:3c and ssid 'erikbandersen.com/freewifi' wlan1: Setup of interface done. MGMT (TX callback) ACK Malformed netlink message: len=436 left=256 plen=420 256 extra bytes in the end of netlink message MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb mgmt::auth authentication: STA=3c:4a:92:0e:41:2f auth_alg=0 auth_transaction=1 status_code=0 wep=0 New STA wlan1: STA 3c:4a:92:0e:41:2f IEEE 802.11: authentication OK (open system) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-AUTHENTICATE.indication(3c:4a:92:0e:41:2f, OPEN_SYSTEM) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-DELETEKEYS.request(3c:4a:92:0e:41:2f) authentication reply: STA=3c:4a:92:0e:41:2f auth_alg=0 auth_transaction=2 resp=0 (IE len=0) MGMT (TX callback) ACK mgmt::auth cb wlan1: STA 3c:4a:92:0e:41:2f IEEE 802.11: authenticated mgmt::assoc_req association request: STA=3c:4a:92:0e:41:2f capab_info=0x421 listen_interval=10 Validating WMM IE: OUI 00:50:f2 OUI type 2 OUI sub-type 0 version 1 QoS info 0x0 HT: STA 3c:4a:92:0e:41:2f HT Capabilities Info: 0x102c handle_assoc STA 3c:4a:92:0e:41:2f - no greenfield, num of non-gf stations 1 handle_assoc STA 3c:4a:92:0e:41:2f - 20 MHz HT, num of 20MHz HT STAs 1 hostapd_ht_operation_update current operation mode=0x0 hostapd_ht_operation_update new operation mode=0x7 changes=2 new AID 1 wlan1: STA 3c:4a:92:0e:41:2f IEEE 802.11: association OK (aid 1) MGMT (TX callback) ACK mgmt::assoc_resp cb wlan1: STA 3c:4a:92:0e:41:2f IEEE 802.11: associated (aid 1) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-ASSOCIATE.indication(3c:4a:92:0e:41:2f) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-DELETEKEYS.request(3c:4a:92:0e:41:2f) wlan1: STA 3c:4a:92:0e:41:2f RADIUS: starting accounting session 4DAC8224-00000000 MGMT (TX callback) ACK mgmt::action cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb Signal 2 received - terminating wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-DEAUTHENTICATE.indication(3c:4a:92:0e:41:2f, 1) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-DELETEKEYS.request(3c:4a:92:0e:41:2f) Removing station 3c:4a:92:0e:41:2f hostapd_ht_operation_update current operation mode=0x7 hostapd_ht_operation_update new operation mode=0x0 changes=2 Flushing old station entries Deauthenticate all stations . Linux erikbandersen 2.6.35-25-generic #44-Ubuntu SMP Fri Jan 21 17:40:44 UTC 2011 x86_64 GNU/Linux Configuration file: hostapd.conf ctrl_interface_group=0 Opening raw packet socket for ifindex 248 BSS count 1, BSSID mask ff:ff:ff:ff:ff:ff (0 bits) SIOCGIWRANGE: WE(compiled)=22 WE(source)=21 enc_capa=0xf nl80211: Added 802.11b mode based on 802.11g information Allowed channel: mode=1 chan=1 freq=2412 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=2 freq=2417 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=3 freq=2422 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=4 freq=2427 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=5 freq=2432 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=6 freq=2437 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=7 freq=2442 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=8 freq=2447 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=9 freq=2452 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=10 freq=2457 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=11 freq=2462 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=1 freq=2412 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=2 freq=2417 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=3 freq=2422 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=4 freq=2427 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=5 freq=2432 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=6 freq=2437 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=7 freq=2442 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=8 freq=2447 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=9 freq=2452 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=10 freq=2457 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=11 freq=2462 MHz max_tx_power=27 dBm HT40: control channel: 2 secondary channel: 6 RATE[0] rate=10 flags=0x2 RATE[1] rate=20 flags=0x6 RATE[2] rate=55 flags=0x6 RATE[3] rate=110 flags=0x6 RATE[4] rate=60 flags=0x0 RATE[5] rate=90 flags=0x0 RATE[6] rate=120 flags=0x0 RATE[7] rate=180 flags=0x0 RATE[8] rate=240 flags=0x0 RATE[9] rate=360 flags=0x0 RATE[10] rate=480 flags=0x0 RATE[11] rate=540 flags=0x0 Passive scanning not supported Mode: IEEE 802.11g Channel: 2 Frequency: 2417 MHz Could not set channel for kernel driver wlan1: Unable to setup interface. My wireless card is listed as 02:00.0 Network controller: Atheros Communications Inc. AR5008 Wireless Network Adapter (rev 01) by lspci. Am I doing it wrong and there's a new way of doing it? I'm holding off upgrading to Natty because of this. What changed between the versions that would cause this? Should I report it as a bug?

    Read the article

  • Enabling hardware acceleration and Xinerama for multi-monitor/multi-GPU in Linux

    - by mynameiscoffey
    My current setup is three monitors connected as follows (monitors listed from left to right): GPU0 (nVidia GTX 280): - Dell 2405FPW (1920x1200) - Dell U2410 (1920x1200) GPU1 (nVidia 210): - Dell 2405FPW (1920x1200) Works like a charm in Windows 7, not so much in Linux. I seem to only have three real options: Run all three monitors as a seperate X screen, I get hardware acceleration but as they are all independent X sessions I cannot move windows between them and can only have firefox open on one at any given time. Run the two on GPU0 in TwinView mode and have GPU1 as a seperate X screen. Same limitation as 1 but at least two monitors work together ok. I did have an issue where occasionally Linux saw both monitors on GPU0 as a single large monitor however. Enable Xinerama and have everything work as I want it to but hardware acceleration is gone and the display is Windows 95 style choppy. My ideal solution would be to have all screens working as they do under Xinerama without the limitation of having hardware acceleration disabled. I don't even care if that means rendering all three on GPU0 and somehow farming out the display of the third monitor to GPU1, whatever works. My question is this: is there any way to accomplish this? I don't feel like my use case is so out there that there shouldn't be at least some form of support (beyond the three limited options presented above), or is my best option going to be to just suck it up and pick up a better card to replace both that can handle three outputs by itself?

    Read the article

  • Change the update channel in Portable Thunderbird?

    - by rubo77
    I think it needs some explanation How to update a TB Portable installation to beta or aurora. I tried to change the preferences in about:config: update.channel to aurora but that had no effect. Then I edited ThunderbirdPortable3\App\thunderbird\defaults\pref\channel-prefs.js and restarted TB. There I got the message in the Help screen, that I am on update channel aurora, which seems fine. Still: the update downloaded Thunderbird 29 pre beta and tried to install but ended with the message that it couldnt be installed due to patch problems: Das Update konnte nicht installiert werden (Patch-Anwendung fehlgeschlagen) I tried this again with the channel "nightly" and got the same error. (On channel "beta" there seem to be no newer version than in the channel "release".) How can I change my installation to channel aurora and update it?

    Read the article

  • How to setup apache multi-site with multi-domain on ec2

    - by Esh
    Say I have two document roots domain1/ and domain2/ I know how to access those two roots from my own computer if they are hosted on the same computer. My question is that if I want to do the same thing on my ec2 server, how should I configure my elastic ips to those two roots? I know by default the elastic ip will only associate to the root with the name localhost(127.0.0.1). Anyone could give me a detailed answer? An example would help, thanks!

    Read the article

  • WCF communication using Channel Factory.

    - by Rob Ferno
    How do I get 2 WCF services to communicate with each other using a Channel Factory in C#? Can someone point me in the right direction. Saw a few examples but was confused how the communication really happens and what code needs to be written to support this.

    Read the article

  • Channel Audio from .mp4?

    - by Kyle
    Hi there. I am at a loss here after searching around with no results. I am attempting to channel the audio specifically from an .mp4 for use in a driver. I am aware that there are programs which extract the audio from .mp4's, but I am looking for another approach without using external applications such as those.. is there any direction that someone can point me towards to solve this problem? Thanks, -K

    Read the article

  • Terminating multi-mode fiber

    - by murisonc
    I'm looking at the feasibility of terminating multi-mode fiber connections ourselves. We would be using LC connectors. I've done some research and found two different methods. One requires polishing the ends and using epoxy while the other doesn't. I like the idea of not having to polish the ends but there doesn't seem to be much information on quality or ease of use. I've found two vendors (3M and Corning) that offer kits for terminating fiber without polishing or using epoxy. Does anyone have any experience with both methods that can offer some advice? Copper is easy but fiber seems to be a whole different animal. EDIT: After looking into fusion splicing suggested in the answer I've determined it's not for us. It's my understanding that is primarily used for outside plant and is better suited for single mode fiber. It's a good answer but doesn't address the question directly. Some more information about our situation. We will only be terminating multi-mode fiber inside a building and only doing between 4 and 20 pair a year. Hiring an outside person won't work due to our location. There are currently a couple people on-site that can terminate fiber (working for another company and charging large fees) but they can only do ST and SC connectors and we only use LC. So once again does anyone have experience with terminating using both epoxy type connectors and the other type (similar to Corning Unicam)?

    Read the article

  • PHP / SSH2 Multi-threading

    - by Asad Moeen
    I'm basically done using SSH2 with PHP. Some may already that while using it, the PHP code actually waits for all the listed commands to be executed in SSH and when everything is done, it then gives back the results. Where that is fine for the work I am doing, but I need some commands to be multi-threaded. $cmd= MyCommand; echo $ssh-exec($cmd); So I just want this to run in parallel 2 times. I googled some stuff but didn't get along with it. For a basic thing, I came across to this way posted by someone but it didn't work out for me. for ($i = 0; $i < 2; $i += 1) { exec("php test_1.php $i > test.txt &"); //this will execute test_1.php and will leave this process executing in the background and will go to next iteration of the loop immediately without waiting the completion of the script in the test_1.php , $i is passed as argument . } I tried to put it this way exec("echo $ssh-exec($cmd) $i test.txt &"); in the loop but either it never entered the loop or the echo $ssh-exec failed. I don't really need a very neat multi-threading. Even a single second delay would do good, thank you.

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >