Search Results

Search found 472 results on 19 pages for 'stefan barrett'.

Page 3/19 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • .htaccess more than one command in the file

    - by Stefan
    Hey I have an .htaccess file with the following code: <Files ~ "item|profile|category|search"> ForceType application/x-httpd-php </Files> What I want is to add a re-write rule as well which changes any body who navigates to the site to use http://www.domain.com sintead of http://domain.com I have the code: RewriteEngine On RewriteCond %{SERVER_PORT} 80 RewriteRule ^(.*)$ http://www.DOMAIN.com/$1 [R,L] however I can't seem to just place in the file as it corrupts? Or just doesn't work... I wish I knew more about .htaccess files How can I add this in? Thanks, Stefan

    Read the article

  • Using the C Cluster library in Visual C++.

    - by Stefan K.
    Right so i'm trying to use a C library in C++, never actually done this before i thought it would be a case of declaring the header includes under a extern "C" and setting the compile as flag to "default" but i'm still getting linker errors and think that the header file might have to be complied as a DLL. I have no idea really. Is it the library that's the problem or is it me? There are some make files in the cluster-1.47\src, but i don't know how or if they relate to "cluster.h". I've uploaded a visual studio 2008 project for anyone to take a gander, any help would be appreciated as i've been hitting my head against the wall for time now. thanks Stefan Link to Visual Studio 2008 Project

    Read the article

  • VMware vSphere cluster design for site redundancy

    - by Stefan Radovanovici
    I have a question about the best design for site redudancy when using vSphere clusters. A bit of background info about our situation first though. We are a medium-sized company with two main offices, located in different countries. Our networks are linked by a Layer2 150Mbps leased line which is currently underused. We have a variety of services running for internal use within the company, some on physycal servers and some on existing vSphere clusters. In our department we also run several services (almost all running under various forms of Linux) like NTP, Syslog, jump servers, monitoring servers and so on. We have now the requirement that those servers need to be redundant within each location (which they are not at the moment) and also site redudant (which they are to some extent, the servers are duplicated in the 2nd location with configurations kept in sync via various methods at the application layer). There is no SAN available for us, at least not something that we can use at the moment. Cost is also an issue. While we do have some budget available for this, we can't afford to buy SANs for both locations for example. I looked at the VSA feature and it seems that this could be something for us but I am unsure how to solve the site-redudancy requirement. At the moment for testing purposes I am setting up in a lab a vSphere 5 with VSA on two ESXi hosts. I am currently using the Essentials Plus kit with VSA license, which allows me to build a VSA cluster on up to 3 hosts, together with a vCenter license to manage them. The hosts each have two dual-port network cards and two 600GB drives, running in Raid1. Hardware-wise this will be enough for us to run the all the services we need as VMs and will provide redundandcy within the site. At the moment I see only two option to have site redundancy: build an identical VSA cluter in the second location and keep the various services sync'ed at application layer (database sync, rsync and so on). simply move one of the hosts from the existing cluster to the second location, basically having the VSA cluster span the 150Mbps link between the sites. I would very much prefer the second option but I am unsure how well it'll work, if it can work at all. Technically it should, we can span the needed VLANs across the leased line and have them available in the second location. The advantage would be that we don't need to worry at all about sync'ing databases and the like. But I have the feeling that the bandwidth will not be enough, I have no way of knowing how much traffic will the VSA cluster generate between the hosts. I realize that this will most likely depend on the individual usage of the VMs but still, I have no idea how VSA replicates data between the ESXi hosts. Are these my only options or can my goals be achieved in some other way ? Is there perhaps a way to have some sort of "cold stand by" cluster in the second location where the VMs would be sync'ed once per night from the main location ? The idea is that in case the first site becomes unavailable, we would be able to bring all those VMs online there. We would be ok with the data being 1 day old. Any answers are appreciated. Best regards, Stefan

    Read the article

  • A really smart rails helper needed

    - by Stefan Liebenberg
    In my rails application I have a helper function: def render_page( permalink ) page = Page.find_by_permalink( permalink ) content_tag( :h3, page.title ) + inline_render( page.body ) end If I called the page "home" with: <%= render_page :home %> and "home" page's body was: <h1>Home<h1/> bla bla <%= render_page :about %> <%= render_page :contact %> I would get "home" page, with "about" and "contact", it's nice and simple... right up to where someone goes and changes the "home" page's content to: <h1>Home<h1/> bla bla <%= render_page :home %> <%= render_page :about %> <%= render_page :contact %> which will result in a infinite loop ( a segment fault on webrick )... How would I change the helper function to something that won't fall into this trap? My first attempt was along the lines of: @@list = [] def render_page( permalink ) unless @@list.include?(permalink) @@list += [ permalink ] page = Page.find_by_permalink result = content_tag( :h3, page.title ) + inline_render( page.body ) @@list -= [ permalink ] return result else content_tag :b, "this page is already being rendered" end end which worked on my development environment, but bombed out in production... any suggestions? Thank You Stefan

    Read the article

  • javascript scope problem when lambda function refers to a variable in enclosing loop

    - by Stefan Blixt
    First question on stackoverflow :) Hope I won't embarrass myself... I have a javascript function that loads a list of albums and then it creates a list item for each album. The list item should be clickable, so I call jQuery's click() with a function that does stuff. I do this in a loop. My problem is that all items seem to get the same click function, even though I try to make a new one that does different stuff in each iteration. Another possibility is that the iteration variable is global somehow, and the function refers to it. Code below. debug() is just an encapsulation of Firebug's console.debug(). function processAlbumList(data, c) { for (var album in data) { var newAlbum = $('<li class="albumLoader">' + data[album].title + '</li>').clone(); var clickAlbum = function() { debug("contents: " + album); }; debug("Album: " + album + "/" + data[album].title); $('.albumlist').append(newAlbum); $(newAlbum).click(clickAlbum); } } Here is a transcript of what it prints when the above function runs, after that are some debug lines caused by me clicking on different items. It always prints "10", which is the last value that the album variable takes (there are 10 albums). Album: 0/Live on radio.electro-music.com Album: 1/Doodles Album: 2/Misc Stuff Album: 3/Drawer Collection Album: 4/Misc Electronic Stuff Album: 5/Odds & Ends Album: 6/Tumbler Album: 7/Bakelit 32 Album: 8/Film Album: 9/Bakelit Album: 10/Slow Zoom/Atomic Heart contents: 10 contents: 10 contents: 10 contents: 10 contents: 10 Any ideas? Driving me up the wall, this is. :) /Stefan

    Read the article

  • VBA: How go I get the total width from all controls in an MS-Access form?

    - by Stefan Åstrand
    Hi, This is probably very basic stuff, but please bear in mind I am completely new to these things. I am working on a procedure for my Access datasheet forms that will: Adjust the width of each column to fit content Sum the total width of all columns and subtract it from the size of the window's width Adjust the width of one of the columns to fit the remaining space This is the code that adjusts the width of each column to fit content (which works fine): Dim Ctrl As Control Dim Path As String Dim ClmWidth As Integer 'Adjust column width to fit content For Each Ctrl In Me.Controls If TypeOf Ctrl Is TextBox Then Path = Ctrl.Name Me(Path).ColumnWidth = -2 End If Next Ctrl How should I write the code so I get the total width of all columns? Thanks a lot! Stefan Solution This is the code that makes an Access datasheet go from this: To this: Sub AdjustColumnWidth(frm As Form, clm As String) On Error GoTo HandleError Dim intWindowWidth As Integer ' Window width property Dim ctrl As Control ' Control Dim intCtrlWidth As Integer ' Control width property Dim intCtrlSum As Integer ' Control width property sum Dim intCtrlAdj As Integer ' Control width property remaining after substracted intCtrSum 'Adjust column width to standard width For Each ctrl In frm.Controls If TypeOf ctrl Is TextBox Or TypeOf ctrl Is CheckBox Or TypeOf ctrl Is ComboBox Then Path = ctrl.Name frm(Path).ColumnWidth = 1500 End If Next ctrl 'Get total column width For Each ctrl In frm.Controls If TypeOf ctrl Is TextBox Or TypeOf ctrl Is CheckBox Or TypeOf ctrl Is ComboBox Then Path = ctrl.Name intCtrlWidth = frm(Path).ColumnWidth If Path <> clm Then intCtrlSum = intCtrlSum + intCtrlWidth End If End If Next ctrl 'Adjust column to fit window intWindowWidth = frm.WindowWidth - 270 intCtrlAdj = intWindowWidth - intCtrlSum frm.Width = intWindowWidth frm(clm).ColumnWidth = intCtrlAdj Debug.Print "Totalt (Ctrl): " & intCtrlSum Debug.Print "Totalt (Window): " & intWindowWidth Debug.Print "Totalt (Remaining): " & intCtrlAdj Debug.Print "clm : " & clm HandleError: GeneralErrorHandler Err.Number, Err.Description Exit Sub End Sub Code to call procedure: Private Sub Form_Load() Call AdjustColumnWidth(Me, "txtDescription") End Sub

    Read the article

  • A really smart rails helper needed

    - by Stefan Liebenberg
    In my rails application I have a helper function: def render_page( permalink ) page = Page.find_by_permalink( permalink ) content_tag( :h3, page.title ) + inline_render( page.body ) end If I called the page "home" with: <%= render_page :home %> and "home" page's body was: <h1>Home<h1/> bla bla <%= render_page :about %> <%= render_page :contact %> I would get "home" page, with "about" and "contact", it's nice and simple... right up to where someone goes and changes the "home" page's content to: <h1>Home<h1/> bla bla <%= render_page :home %> <%= render_page :about %> <%= render_page :contact %> which will result in a infinite loop ( a segment fault on webrick )... How would I change the helper function to something that won't fall into this trap? My first attempt was along the lines of: @@list = [] def render_page( permalink ) unless list.include?(permalink) @@list += [ permalink ] page = Page.find_by_permalink content_tag( :h3, page.title ) + inline_render( page.body ) @@list -= [ permalink ] else content_tag :b, "this page is already being rendered" end end which worked on my development environment, but bombed out in production... any suggestions? Thank You Stefan

    Read the article

  • SQL: How do I INSERT primary key values from two tables INTO a master table.

    - by Stefan
    Hello, I would appreciate some help with an SQL statement I really can't get my head around. What I want to do is fairly simple, I need to take the values from two different tables and copy them into an master table when a new row is inserted into one of the two tables. The problem is perhaps best explained like this: I have three tables, productcategories, regioncategories and mastertable. --------------------------- TABLE: PRODUCTCATEGORIES --------------------------- COLUMNS: CODE | DESCRIPTION --------------------------- VALUES: BOOKS | Books --------------------------- --------------------------- TABLE: REGIONCATEGORIES --------------------------- COLUMNS: CODE | DESCRIPTION --------------------------- VALUES: EU | European Union --------------------------- --------------------------- TABLE: MASTERTABLE --------------------------- COLUMNS: REGION | PRODUCT --------------------------- VALUES: EU | BOOKS --------------------------- I want the values to be inserted like this when a new row is created in either productcategories or regioncategories. New row is created. --------------------------- TABLE: PRODUCTCATEGORIES --------------------------- COLUMNS: CODE | DESCRIPTION --------------------------- VALUES: BOOKS | Books --------------------------- VALUES: DVD | DVDs --------------------------- And a SQL statement copies the new values into the mastertable. --------------------------- TABLE: MASTERTABLE --------------------------- COLUMNS: REGION | PRODUCT --------------------------- VALUES: EU | BOOKS --------------------------- VALUES: EU | DVD --------------------------- The same goes if a row is created in the regioncategories. New row. --------------------------- TABLE: REGIONCATEGORIES --------------------------- COLUMNS: CODE | DESCRIPTION --------------------------- VALUES: EU | European Union --------------------------- VALUES: US | United States --------------------------- Copied to the mastertable. --------------------------- TABLE: MASTERTABLE --------------------------- COLUMNS: REGION | PRODUCT --------------------------- VALUES: EU | BOOKS --------------------------- VALUES: EU | DVD --------------------------- VALUES: US | BOOKS --------------------------- VALUES: US | DVD --------------------------- I hope it makes sense. Thanks, Stefan

    Read the article

  • My jQuery and PHP give different results on the same thing?

    - by Stefan
    Hey all, Annoying brain numbing problem. I have two functions to check the length of a string (primarily, the js one truncates as well) heres the one in Javascript: $('textarea#itemdescription').keyup(function() { var charLength = $(this).val().length; // Displays count $('span#charCount').css({'color':'#666'}); $('span#charCount').html(255 - charLength); if($(this).val().length >= 240){ $('span#charCount').css({'color':'#FF0000'}); } // Alerts when 250 characters is reached if($(this).val().length >= 255){ $('span#charCount').css({'color':'#FF0000'}); $('span#charCount').html('<strong>0</strong>'); var text = $('textarea#itemdescription').val().substring(0,255) $('textarea#itemdescription').val(text); } }); And here is my PHP to double check: if(strlen($_POST["description"])>255){ echo "Description must be less than ".strlen($_POST["description"])." characters"; exit(); } I'm using jQuery Ajax to post the values from the textarea. However my php validation says the strlen() is longer than my js is essentially saying. So for example if i type a solid string and it says 0 or 3 chars left till 255. I then click save and the php gives me the length as being 261. Any ideas? Is it to do with special characters, bit sizes that js reads differently or misses out? Or is it to do with something else? Maybe its ill today!... :P Thanks, Stefan

    Read the article

  • SQL wont work? It doesn't come up with errors either

    - by Stefan
    Hey there, I have php function which checks to see if variables are set and then adds them onto my sql query. However I am don't seem to be getting any results back!? $where_array = array(); if (array_key_exists("location", $_GET)) { $location = addslashes($_GET['location']); $where_array[] = "`mainID` = '".$location."'"; } if (array_key_exists("gender", $_GET)) { $gender = addslashes($_GET["gender"]); $where_array[] = "`gender` = '".$gender."'"; } if (array_key_exists("hair", $_GET)) { $hair = addslashes($_GET["hair"]); $where_array[] = "`hair` = '".$hair."'"; } if (array_key_exists("area", $_GET)) { $area = addslashes($_GET["area"]); $where_array[] = "`locationID` = '".$area."'"; } $where_expr = ''; if ($where_array) { $where_expr = "WHERE " . implode(" AND ", $where_array); } $sql = "SELECT `postID` FROM `posts` ". $where_expr; $dbi = new db(); $result = $dbi->query($sql); $r = mysql_fetch_row($result); I'm trying to call the data after in a list like so: $dbi = new db(); $offset = ($currentpage - 1) * $rowsperpage; // get the info from the db $sql .= " ORDER BY `time` DESC LIMIT $offset, $rowsperpage"; $result = $dbi->query($sql); // while there are rows to be fetched... while ($row = mysql_fetch_object($result)){ // echo data echo $row['text']; } // end while Anyone got any ideas why I am not retrieving any data? -Stefan

    Read the article

  • Rand(); with exclusion to and already randomly generated number..?

    - by Stefan
    Hey, I have a function which calls a users associated users from a table. The function then uses the rand(); function to chose from the array 5 randomly selected userID's however!... In the case where a user doesnt have many associated users but above the min (if below the 5 it just returns the array as it is) then it gives bad results due to repeat rand numbers... How can overcome this or exclude a previously selected rand number from the next rand(); function call. Here is the section of code doing the work. Bare in mind this must be highly efficient as this script is used everywhere. $size = sizeof($users)-1; $nusers[0] = $users[rand(0,$size)]; $nusers[1] = $users[rand(0,$size)]; $nusers[2] = $users[rand(0,$size)]; $nusers[3] = $users[rand(0,$size)]; $nusers[4] = $users[rand(0,$size)]; return $nusers; Thanks in advance! Stefan

    Read the article

  • sql statement question. Need to query 3 tables in one go!

    - by Stefan
    Hey there, I have an sql database. In this database is 3 tables I need to query. The first table has all the item info called item and the other two tables has data for votes and comments called userComment and the third for votes called userItem I currently have a function which uses this sql query to get the latest more popular (in terms of both votes and comments): $sql = "SELECT itemID, COUNT(*) AS cnt FROM ( SELECT `itemID` FROM `userItem` WHERE FROM_UNIXTIME( `time` ) >= NOW() - INTERVAL 1 DAY UNION ALL SELECT `itemID` FROM `userComment` WHERE FROM_UNIXTIME( `time` ) >= NOW() - INTERVAL 1 DAY AND `itemID` > 0 ) q GROUP BY `itemID` ORDER BY cnt DESC"; I know how to change this for either by votes alone or comments.... HOWEVER - I need to query the database to only return the itemID's of the ones which have specific conditions in only the item table these are WHERE categoryID = 'xx' AND typeID = 'xx' If the sql ninja could please help me on this one? Do I have to first return the results from the above query and the for each in the array fetched then check each against the item table and see if it fits the conditions to build a new array - or is that overkill? Thanks, Stefan

    Read the article

  • Setup Custom Portal & Content Enabled Domain

    - by Stefan Krantz
    When overlooking the past year we have seen a large increase in deployments where only some parts of the WebCenter Suite infrastructure has been used. The most common from my personal perspective is a domain topology that includes: WebCenter Custom Portal, WebCenter Content and Oracle HTTP ServicesToday its very common to see installation where the whole suite is installed when the use case only requires the custom portal and some sub component like WebCenter Content. This post will go into detail on how to minimize the deployment time and effort by only laying down the necessary managed servers needed, by following this proposed method you will minimize the configuration steps and only install the required components and schema's, configure only the necessary components and minimize the impact of architectural changes through reduced dependencies. Assumptions: Oracle 11g Database installed SYS or equivalent access to Database to setup schema's via RCU Running Operating System supporting JDK 7 Update 2 (Check support matrix here) Good understanding of WebLogic Architecture Binaries: Oracle JDK 7 Update 2 (1.7.0_02) (Download) Oracle WebLogic 10.3.6 (Download) Oracle WebCenter Binaries (11.1.1.6) (Download) Oracle WebCenter Content Binaries (11.1.1.6) (Download 1) (Download 2) Oracle HTTP Services (11.1.1.6) (Download) Oracle Repository Creation Utility (11.1.1.6) (Download Linux or Windows) Schema's: Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} MDS - Meta Data Services (WebCenter and OWSM) WebCenter (WebCenter Schema) OCS (Oracle WebCenter Content) Activities (WebCenter Activities) OPSS (Policy Store for WebCenter) Installation Structure: - [Installation Home]/Middleware    - Oracle_WC1 (WebCenter Installation)    - Oracle_WT1 (Oracle WebTier)    - Oracle_ECM (WebCenter Content)    - wlserver_10.3 (Weblogic installation)- [Installation Home]/domains    - webcenter (WebCenter Domain)    - instances (OHS/OPMN instance)- [Installation Home]/applications- [Installation Home]/JDK1.7.0_02 Installation and Configuration Steps: Install Java and configure Java Home Extract the Java Installable (jdk-7u2-linux-x64) to [Installation Home]/JDK1.7.0_02 Add JAVA_HOME to Environment Settings (JAVA_HOME=[Installation Home]/JDK1.7.0_02) Update PATH in Environment Settings (PATH=$JAVA_HOME/bin:$PATH) Install WebLogic Server (Middleware Home) Run the installer / execute jar file (java - jar wls1036_generic.jar) Create the Middleware Home under [Installation Home]/Middleware Install WebCenter Portal (Extend Middleware Home) Extract the compressed file (ofm_wc_generic_11.1.1.6.0_disk1_1of1.zip) to a temp folder Execute runInstaller under folder (DISK1/) with following command (runInstaller -jreLoc $JAVA_HOME) Make sure to install in following structure ([Installation Home]/Middleware/Oracle_WC1) Install WebCenter Content (Extend Middleware Home) Extract the compressed files (ofm_wcc_generic_11.1.1.6.0_disk1_1of2.zip & ofm_wcc_generic_11.1.1.6.0_disk1_2of2.zip) to the same temp folder Execute runInstaller under folder (DISK1/) with following command (runInstaller -jreLoc $JAVA_HOME) Make sure to install in following structure ([Installation Home]/Middleware/Oracle_ECM) Configure Initial Domain (Domain name webcenter) Execute configuration tool - [Installation Home]/Middleware/wlserver_10.3/common/bin/config Select "Create a New Weblogic Domain" Select following template (Basic Weblogic Server Domain, Oracle Enterprise Manager, Oracle WSM Policy Manager, Oracle JRF) Create new domain with name webcenter under following location ([Installation Home]/domains) for applications ([Installation Home]/applications) Select Production Mode Finish Configuration wizard Setup username for startup scripts - Add a new file called boot.properties to ([Installation Home]/domains/webcenter/servers/AdminServer/security)Add following lines to boot.propertiesusername=weblogicpassword=[password clear text, it will be encrypted during first start] Start AdminServer in the background ([Installation Home]/domains/webcenter/bin/startWeblogic) Install and Configure Oracle WebTier (OHS Server) Extract compressed file (ofm_webtier_linux_11.1.1.6.0_64_disk1_1of1.zip) to a temp folder Execute runInstaller under folder (DISK1/) with following command (runInstaller) Select Install & Configure option Deselect Oracle WebCache Auto Configure Ports Configure Schema's with RCU (Repository Creation Utility) Extract compressed file (ofm_rcu_linux_11.1.1.6.0_disk1_1of1.zip) to a temp folder Execute rcu with following command ([temp]/rcuHome/rcu) Make sure database meets RCU requirements, particular (PROCESSES is 200 or more) Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Using SQLPLUS and sys user tou can update this configuration in the database with following procedure:ALTER SYSTEM SET PROCESSES=200 SCOPE=SPFILE shutdown immediate startup Create and Configure following schemas:MDS - Meta Data Services (WebCenter and OWSM)WebCenter (WebCenter Schema)OCS (Oracle WebCenter Content)Activities (WebCenter Activities)OPSS (Policy Store for WebCenter) Remember selected schema prefix and password (will be used later) Configure WebCenter Portal instance (WC_CustomPortal) Execute following command to start configuration wizard ([Installation Home]/Middleware/Oracle_WC1/common/bin/config) Select Extend an Existing WebLogic domain Select the existing webcenter domain ([Installation Home]/domains/webcenter) Select Extend my domain using existing extension templateBrowse to ([Installation Home]/Middleware/Oracle_WC1/common/templates/applications)Select oracle.wc_custom_portal_template_11.1.1.jar Select to configure (Managed Servers/Clusters/Machines) On the Managed Server Screen you can now configure 1 or more WC_CustomPortal managed servers (name them WC_CustomPortal[n] (skip numbering if not clustered)) In case of two WC_CustomPortal Servers then create a Cluster (any name) and make sure the managed servers join the new cluster Create a new machine with same name as the current machine Make sure the AdminServer and WC_CustomPortal[n] managed servers joins the machine Finish the configuration wizard Stop AdminServer ([Installation Home]/domains/webcenter/bin/stopWeblogic) Start AdminServer in the background ([Installation Home]/domains/webcenter/bin/startWeblogic) Start WC_CustomPortal in the foreground (([Installation Home]/domains/webcenter/bin/startManagedServer WC_CustomPortal))- repeat for each WC_CustomPortal instance on the host Give credentials for weblogic user on start up Copy folder security including file boot.properties - from ([Installation Home]/domains/webcenter/servers/AdminServer/) to ([Installation Home]/domains/webcenter/servers/WC_CustomPortal/) Result should be ([Installation Home]/domains/webcenter/servers/WC_CustomPortal/security/boot.properties) Configure WebCenter Content instance (UCM_server1) Execute following command to start configuration wizard ([Installation Home]/Middleware/Oracle_ECM/common/bin/config) Select Extend an Existing WebLogic domain Select Oracle Universal Content Management - Content Server Select to configure (Managed Servers/Clusters/Machines) On Managed Server Screen create only one managed server instance (UCM_server1 on port 16200 (you can select any other available port)) Make sure the UCM_server1 managed server joins the machine Finish the configuration wizard Stop AdminServer ([Installation Home]/domains/webcenter/bin/stopWeblogic) Start AdminServer in the background ([Installation Home]/domains/webcenter/bin/startWeblogic) Start UCM_server1 in the foreground ([Installation Home]/domains/webcenter/bin/startManagedServer UCM_server1)Give credentials for weblogic user on start up Copy folder security including file boot.properties - from ([Installation Home]/domains/webcenter/servers/AdminServer/) to ([Installation Home]/domains/webcenter/servers/UCM_server1/ Result should be ([Installation Home]/domains/webcenter/servers/UCM_server1/security/boot.properties) Post Configure WebCenter Content instance for WebCenter Portal Open a browser where you have support for Java applets - navigate to http://host:port/cs WARNING: The page that you are presented with after authentication will only appear once for each instance WARNING: Make sure you set correct storage options - also remember to consider file sharing options if you like to cluster your Content Server instance over multiple hosts Set an appropriate Auto number prefix Update the Server Socket Port: Commonly set to (4444)  used for RIDC communication (a requirement for WebCenter Portal) Update the IP Address Filter to include the IP that is planned to access the server over RIDC - at the minimum add the ip address of the current host (this option can be updated later via EM) Stop UCM_server1 ([Installation Home]/domains/webcenter/bin/stopManagedServer UCM_server1) Start UCM_server1 in the background([Installation Home]/domains/webcenter/bin/startManagedServer UCM_server1) Open a browser where you have support for Java applets - navigate to http://host:port/cs Navigate to Administration/Admin Server Go to General ConfigurationCheck Enable AccountsIn Additional Configuration Variables (Add on two lines) Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} AllowUpdateForGenwww=1CollectionUseCache=1 Save the changes and go to Component Manager Click on the link advanced component manager Enable following components Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Folders_g, WebCenterConfigure, SiteStudio, SiteStudioExternalApplications, DBSearchContainsOpSupport WARNING: Make sure that following component is disabled: FrameworkFolders Stop UCM_server1 ([Installation Home]/domains/webcenter/bin/stopManagedServer UCM_server1) Start UCM_server1 in the background([Installation Home]/domains/webcenter/bin/startManagedServer UCM_server1) Open a browser where you have support for Java applets - navigate to http://host:port/cs Navigate to Administration/Site Studio Administration and update - Do not forget to save and submit each page Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Set Default ProjectSet Default WebAssets Post Configure Oracle WebTier (OHS) to include Content Server and WebCenter Portal application context Update following file - [Installation Home]/domains/instances/instance1/config/OHS/ohs1/mod_wl_ohs.conf For single add lines from following example: Link For clustered environment add lines from following template (note the clustering in example on applies to WC_CustomPortal): Link For more information on this: http://docs.oracle.com/cd/E23943_01/core.1111/e12037/contentsvr.htm#WCEDG318 Optional - Configure JOC Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Follow instructions: http://docs.oracle.com/cd/E23943_01/core.1111/e12037/extend_wc.htm#WCEDG264 Optional (Recommended) - Configure Node Manager Follow instructions: Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} http://docs.oracle.com/cd/E23943_01/core.1111/e12037/node_manager.htm#WCEDG277 Optional (Mandatory for clustered environments) - Re-Associate Policy Store to Database or OID Follow instructions: Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} http://docs.oracle.com/cd/E23943_01/webcenter.1111/e12405/wcadm_security_credstore.htm#CFHDEDJH Optional - Configure Coherence for Content Presenter Follow instructions in Blog Post (This post is for PS4): https://blogs.oracle.com/ATEAM_WEBCENTER/entry/enabling_coherence_for_content_presenter Other Recommended Post Cloning WebCenter Custom Portal - https://blogs.oracle.com/ATEAM_WEBCENTER/entry/cloning_a_webcenter_portal_managedImproving WebCenter Performance through caching - https://blogs.oracle.com/ATEAM_WEBCENTER/entry/improving_webcenter_performance

    Read the article

  • Is CUDA, cuBLAS or cuBLAS-XT the right place to start with for machine learning?

    - by Stefan R. Falk
    I am not sure if this is the right forum to post this question - but it surely is no question for stackoverflow. I work on my bachelor thesis and therefore I am implementing a so called Echo-State Network which basically is an artificial neural network that has a large reservoir of randomly initialized neurons and just a few input and output neurons .. but I think we can skip that. The thing is, there is a Python library called Theano which I am using for this implementation. It encapsulates the CUDA API and offers a quiet "comfortable" way to access the power of a NVIDIA graphics card. Since CUDA 6.0 there is a sub-library called cuBLAS (Basic Linear Algebra Subroutines) for LinAlg operations and also a cuBLAS-XT an extention which allows to run calculations on multiple graphics cards. My question at this point is if it would make sense to start using cuBLAS and/or cuBLAS-XT right now since the API is quite complex or rather wait for libraries that will build up on those library (such as Theano does on basic CUDA)? If you think this is the wrong place for this question please tell me which one is, thank you.

    Read the article

  • Queued Loadtest to remove Concurrency issues using Shared Data Service in OpenScript

    - by stefan.thieme(at)oracle.com
    Queued Processing to remove Concurrency issues in Loadtest ScriptsSome scripts act on information returned by the server, e.g. act on first item in the returned list of pending tasks/actions. This may lead to concurrency issues if the virtual users simulated in a load test scenario are not synchronized in some way.As the load test cases should be carried out in a comparable and straight forward manner simply cancel a transaction in case a collision occurs is clearly not an option. In case you increase the number of virtual users this approach would lead to a high number of requests for the early steps in your transaction (e.g. login, retrieve list of action points, assign an action point to the virtual user) but later steps would be rarely visited successfully or at all, depending on the application logic.A way to tackle this problem is to enqueue the virtual users in a Shared Data Service queue. Only the first virtual user in this queue will be allowed to carry out the critical steps (retrieve list of action points, assign an action point to the virtual user) in your transaction at any one time.Once a virtual user has passed the critical path it will dequeue himself from the head of the queue and continue with his actions. This does theoretically allow virtual users to run in parallel all steps of the transaction which are not part of the critical path.In practice it has been seen this is rarely the case, though it does not allow adding more than N users to perform a transaction without causing delays due to virtual users waiting in the queue. N being the time of the total transaction divided by the sum of the time of all critical steps in this transaction.While this problem can be circumvented by allowing multiple queues to act on individual segments of the list of actions, e.g. per country filter, ends with 0..9 filter, etc.This would require additional handling of these additional queues of slots for the virtual users at the head of the queue in order to maintain the mutually exclusive access to the first element in the list returned by the server at any one time of the load test. Such an improved handling of multiple queues and/or multiple slots is above the subject of this paper.Shared Data Services Pre-RequisitesStart WebLogic Server to host Shared Data ServicesYou will have to make sure that your WebLogic server is installed and started. Shared Data Services may not work if you installed only the minimal installation package for OpenScript. If however you installed the default package including OLT and OTM, you may follow the instructions below to start and verify WebLogic installation.To start the WebLogic Server deployed underneath of Oracle Load Testing and/or Oracle Test Manager you can go to your Start menu, Oracle Application Testing Suite and select the Restart Oracle Application Testing Suite Application Service entry from the Tools submenu.To verify the service has been started you can run the Microsoft Management Console for Services by Selecting Run from the Start Menu and entering services.msc. Look for the entry that reads Oracle Application Testing Suite Application Service, once it has changed it status from Starting to Started you can proceed to verify the login. Please note that this may take several minutes, I would say up to 10 minutes depending on the strength of your CPU horse-power.Verify WebLogic Server user credentialsYou will have to make sure that your WebLogic Server is installed and started. Next open the Oracle WebLogic Server Adminstration Console on http://localhost:8088/console.It may take a while until the application is deployed and started. It may display the following until the Administration Console has been deployed on the fly.Afterwards you can login using the username oats and the password that you selected during install time for your Application Testing Suite administrative purposes.This will bring up the Home page of you WebLogic Server. You have actually verified that you are able to login with these credentials already. However if you want to check the details, navigate to Security Realms, myrealm, Users and Groups tab.Here you could add users to your WebLogic Server which could be used in the later steps. Details on the Groups required for such a custom user to work are exceeding this quick overview and have to be selected with the WebLogic Server Adminstration Guide in mind.Shared Data Services pre-requisites for Load testingOpenScript Preferences have to be set to enable Encryption and provide a default Shared Data Service Connection for Playback.These are pre-requisites you want to use for load testing with Shared Data Services.Please note that the usage of the Connection Parameters (individual directive in the script) for Shared Data Services did not playback reliably in the current version 9.20.0370 of Oracle Load Testing (OLT) and encryption of credentials still seemed to be mandatory as well.General Encryption settingsSelect OpenScript Preferences from the View menu and navigate to the General, Encryption entry in the tree on the left. Select the Encrypt script data option from the list and enter the same password that you used for securing your WebLogic Server Administration Console.Enable global shared data access credentialsSelect OpenScript Preferences from the View menu and navigate to the Playback, Shared Data entry in the tree on the left. Enable the global shared data access credentials and enter the Address, User name and Password determined for your WebLogic Server to host Shared Data Services.Please note, that you may want to replace the localhost in Address with the hosts realname in case you plan to run load tests with Loadtest Agents running on remote systems.Queued Processing of TransactionsEnable Shared Data Services Module in Script PropertiesThe Shared Data Services Module has to be enabled for each Script that wants to employ the Shared Data Service Queue functionality in OpenScript. It can be enabled under the Script menu selecting Script Properties. On the Script Properties Dialog select the Modules section and check Shared Data to enable Shared Data Service Module for your script. Checking the Shared Data Services option will effectively add a line to your script code that adds the sharedData ScriptService to your script class of IteratingVUserScript.@ScriptService oracle.oats.scripting.modules.sharedData.api.SharedDataService sharedData;Record your scriptRecord your script as usual and then add the following things for Queue handling in the Initialize code block, before the first step and after the last step of your critical path and in the Finalize code block.The java code to be added at individual locations is explained in the following sections in full detail.Create a Shared Data Queue in InitializeTo create a Shared Data Queue go to the Java view of your script and enter the following statements to the initialize() code block.info("Create queueA with life time of 120 minutes");sharedData.createQueue("queueA", 120);This will create an instantiation of the Shared Data Queue object named queueA which is maintained for upto 120 minutes.If you want to use the code for multiple scripts, make sure to use a different queue name for each one here and in the subsequent steps. You may even consider to use a dynamic queueName based on filters of your result list being concurrently accessed.Prepare a unique id for each IterationIn order to keep track of individual virtual users in our queue we need to create a unique identifier from the virtual user id and the used username right after retrieving the next record from our databank file.getDatabank("Usernames").getNextDatabankRecord();getVariables().set("usernameValue1","VU_{{@vuid}}_{{@iterationnum}}_{{db.Usernames.Username}}_{{@timestamp}}_{{@random(10000)}}");String usernameValue = getVariables().get("usernameValue1");info("Now running virtual user " + usernameValue);As you can see from the above code block, we have set the OpenScript variable usernameValue1 to VU_{{@vuid}}_{{@iterationnum}}_{{db.Usernames.Username}}_{{@timestamp}}_{{@random(10000)}} which is a concatenation of the virtual user id and the iterationnumber for general uniqueness; as well as the username from our databank, the timestamp and a random number for making it further unique and ease spotting of errors.Not all of these fields are actually required to make it really unique, but adding the queue name may also be considered to help troubleshoot multiple queues.The value is then retrieved with the getVariables.get() method call and assigned to the usernameValue String used throughout the script.Please note that moving the getDatabank("Usernames").getNextDatabankRecord(); call to the initialize block was later considered to remove concurrency of multiple virtual users running with the same userid and therefor accessing the same "My Inbox" in step 6. This will effectively give each virtual user a userid from the databank file. Make sure you have enough userids to remove this second hurdle.Enqueue and attend Queue before Critical PathTo maintain the right order of virtual users being allowed into the critical path of the transaction the following pseudo step has to be added in front of the first critical step. In the case of this example this is right in front of the step where we retrieve the list of actions from which we select the first to be assigned to us.beginStep("[0] Waiting in the Queue", 0);{info("Enqueued virtual user " + usernameValue + " at the end of queueA");sharedData.offerLast("queueA", usernameValue);info("Wait until the user is the first in queueA");String queueValue1 = null;do {// we wait for at least 0.7 seconds before we check the head of the// queue. This is the time it takes one user to move through the// critical path, i.e. pass steps [5] Enter country and [6] Assign// to meThread.sleep(700);queueValue1 = (String) sharedData.peekFirst("queueA");info("The first user in queueA is currently: '" + queueValue1 + "' " + queueValue1.getClass() + " length " + queueValue1.length() );info("The current user is '"+ usernameValue + "' " + usernameValue.getClass() + " length " + usernameValue.length() + ": indexOf " + usernameValue.indexOf(queueValue1) + " equals " + usernameValue.equals(queueValue1) );} while ( queueValue1.indexOf(usernameValue) < 0 );info("Now the user is the first in queueA");}endStep();This will enqueue the username to the tail of our Queue. It will will wait for at least 700 milliseconds, the time it takes for one user to exit the critical path and then compare the head of our queue with it's username. This last step will be repeated while the two are not equal (indexOf less than zero). If they are equal the indexOf will yield a value of zero or larger and we will perform the critical steps.Dequeue after Critical PathAfter the virtual user has left the critical path and complete its last step the following code block needs to dequeue the virtual user. In the case of our example this is right after the action has been actually assigned to the virtual user. This will allow the next virtual user to retrieve the list of actions still available and in turn let him make his selection/assignment.info("Get and remove the current user from the head of queueA");String pollValue1 = (String) sharedData.pollFirst("queueA");The current user is removed from the head of the queue. The next one will now be able to match his username against the head of the queue.Clear and Destroy Queue for FinishWhen the script has completed, it should clear and destroy the queue. This code block can be put in the finish block of your script and/or in a separate script in order to clear and remove the queue in case you have spotted an error or want to reset the queue for some reason.info("Clear queueA");sharedData.clearQueue("queueA");info("Destroy queueA");sharedData.destroyQueue("queueA");The users waiting in queueA are cleared and the queue is destroyed. If you have scripts still executing they will be caught in a loop.I found it better to maintain a separate Reset Queue script which contained only the following code in the initialize() block. I use to call this script to make sure the queue is cleared in between multiple Loadtest runs. This script could also even be added as the first in a larger scenario, which would execute it only once at very start of the Loadtest and make sure the queues do not contain any stale entries.info("Create queueA with life time of 120 minutes");sharedData.createQueue("queueA", 120);info("Clear queueA");sharedData.clearQueue("queueA");This will create a Shared Data Queue instance of queueA and clear all entries from this queue.Monitoring QueueWhile creating the scripts it was useful to monitor the contents, i.e. the current first user in the Queue. The following code block will make sure the Shared Data Queue is accessible in the initialize() block.info("Create queueA with life time of 120 minutes");sharedData.createQueue("queueA", 120);In the run() block the following code will continuously monitor the first element of the Queue and write an informational message with the current username Value to the Result window.info("Monitor the first users in queueA");String queueValue1 = null;do {queueValue1 = (String) sharedData.peekFirst("queueA");if (queueValue1 != null)info("The first user in queueA is currently: '" + queueValue1 + "' " + queueValue1.getClass() + " length " + queueValue1.length() );} while ( true );This script can be run from OpenScript parallel to a loadtest performed by the Oracle Load Test.However it is not recommend to run this in a production loadtest as the performance impact is unknown. Accessing the Queue's head with the peekFirst() method has been reported with about 2 seconds response time by both OpenScript and OTL. It is advised to log a Service Request to see if this could be lowered in future releases of Application Testing Suite, as the pollFirst() and even offerLast() writing to the tail of the Queue usually returned after an average 0.1 seconds.Debugging QueueWhile debugging the scripts the following was useful to remove single entries from its head, i.e. the current first user in the Queue. The following code block will make sure the Shared Data Queue is accessible in the initialize() block.info("Create queueA with life time of 120 minutes");sharedData.createQueue("queueA", 120);In the run() block the following code will remove the first element of the Queue and write an informational message with the current username Value to the Result window.info("Get and remove the current user from the head of queueA");String pollValue1 = (String) sharedData.pollFirst("queueA");info("The first user in queueA was currently: '" + pollValue1 + "' " + pollValue1.getClass() + " length " + pollValue1.length() );ReferencesOracle Functional Testing OpenScript User's Guide Version 9.20 [E15488-05]Chapter 17 Using the Shared Data Modulehttp://download.oracle.com/otn/nt/apptesting/oats-docs-9.21.0030.zipOracle Fusion Middleware Oracle WebLogic Server Administration Console Online Help 11g Release 1 (10.3.4) [E13952-04]Administration Console Online Help - Manage users and groupshttp://download.oracle.com/docs/cd/E17904_01/apirefs.1111/e13952/taskhelp/security/ManageUsersAndGroups.htm

    Read the article

  • What's up with LDoms: Part 4 - Virtual Networking Explained

    - by Stefan Hinker
    I'm back from my summer break (and some pressing business that kept me away from this), ready to continue with Oracle VM Server for SPARC ;-) In this article, we'll have a closer look at virtual networking.  Basic connectivity as we've seen it in the first, simple example, is easy enough.  But there are numerous options for the virtual switches and virtual network ports, which we will discuss in more detail now.   In this section, we will concentrate on virtual networking - the capabilities of virtual switches and virtual network ports - only.  Other options involving hardware assignment or redundancy will be covered in separate sections later on. There are two basic components involved in virtual networking for LDoms: Virtual switches and virtual network devices.  The virtual switch should be seen just like a real ethernet switch.  It "runs" in the service domain and moves ethernet packets back and forth.  A virtual network device is plumbed in the guest domain.  It corresponds to a physical network device in the real world.  There, you'd be plugging a cable into the network port, and plug the other end of that cable into a switch.  In the virtual world, you do the same:  You create a virtual network device for your guest and connect it to a virtual switch in a service domain.  The result works just like in the physical world, the network device sends and receives ethernet packets, and the switch does all those things ethernet switches tend to do. If you look at the reference manual of Oracle VM Server for SPARC, there are numerous options for virtual switches and network devices.  Don't be confused, it's rather straight forward, really.  Let's start with the simple case, and work our way to some more sophisticated options later on.  In many cases, you'll want to have several guests that communicate with the outside world on the same ethernet segment.  In the real world, you'd connect each of these systems to the same ethernet switch.  So, let's do the same thing in the virtual world: root@sun # ldm add-vsw net-dev=nxge2 admin-vsw primary root@sun # ldm add-vnet admin-net admin-vsw mars root@sun # ldm add-vnet admin-net admin-vsw venus We've just created a virtual switch called "admin-vsw" and connected it to the physical device nxge2.  In the physical world, we'd have powered up our ethernet switch and installed a cable between it and our big enterprise datacenter switch.  We then created a virtual network interface for each one of the two guest systems "mars" and "venus" and connected both to that virtual switch.  They can now communicate with each other and with any system reachable via nxge2.  If primary were running Solaris 10, communication with the guests would not be possible.  This is different with Solaris 11, please see the Admin Guide for details.  Note that I've given both the vswitch and the vnet devices some sensible names, something I always recommend. Unless told otherwise, the LDoms Manager software will automatically assign MAC addresses to all network elements that need one.  It will also make sure that these MAC addresses are unique and reuse MAC addresses to play nice with all those friendly DHCP servers out there.  However, if we want to do this manually, we can also do that.  (One reason might be firewall rules that work on MAC addresses.)  So let's give mars a manually assigned MAC address: root@sun # ldm set-vnet mac-addr=0:14:4f:f9:c4:13 admin-net mars Within the guest, these virtual network devices have their own device driver.  In Solaris 10, they'd appear as "vnet0".  Solaris 11 would apply it's usual vanity naming scheme.  We can configure these interfaces just like any normal interface, give it an IP-address and configure sophisticated routing rules, just like on bare metal.  In many cases, using Jumbo Frames helps increase throughput performance.  By default, these interfaces will run with the standard ethernet MTU of 1500 bytes.  To change this,  it is usually sufficient to set the desired MTU for the virtual switch.  This will automatically set the same MTU for all vnet devices attached to that switch.  Let's change the MTU size of our admin-vsw from the example above: root@sun # ldm set-vsw mtu=9000 admin-vsw primary Note that that you can set the MTU to any value between 1500 and 16000.  Of course, whatever you set needs to be supported by the physical network, too. Another very common area of network configuration is VLAN tagging. This can be a little confusing - my advise here is to be very clear on what you want, and perhaps draw a little diagram the first few times.  As always, keeping a configuration simple will help avoid errors of all kind.  Nevertheless, VLAN tagging is very usefull to consolidate different networks onto one physical cable.  And as such, this concept needs to be carried over into the virtual world.  Enough of the introduction, here's a little diagram to help in explaining how VLANs work in LDoms: Let's remember that any VLANs not explicitly tagged have the default VLAN ID of 1. In this example, we have a vswitch connected to a physical network that carries untagged traffic (VLAN ID 1) as well as VLANs 11, 22, 33 and 44.  There might also be other VLANs on the wire, but the vswitch will ignore all those packets.  We also have two vnet devices, one for mars and one for venus.  Venus will see traffic from VLANs 33 and 44 only.  For VLAN 44, venus will need to configure a tagged interface "vnet44000".  For VLAN 33, the vswitch will untag all incoming traffic for venus, so that venus will see this as "normal" or untagged ethernet traffic.  This is very useful to simplify guest configuration and also allows venus to perform Jumpstart or AI installations over this network even if the Jumpstart or AI server is connected via VLAN 33.  Mars, on the other hand, has full access to untagged traffic from the outside world, and also to VLANs 11,22 and 33, but not 44.  On the command line, we'd do this like this: root@sun # ldm add-vsw net-dev=nxge2 pvid=1 vid=11,22,33,44 admin-vsw primary root@sun # ldm add-vnet admin-net pvid=1 vid=11,22,33 admin-vsw mars root@sun # ldm add-vnet admin-net pvid=33 vid=44 admin-vsw venus Finally, I'd like to point to a neat little option that will make your live easier in all those cases where configurations tend to change over the live of a guest system.  It's the "id=<somenumber>" option available for both vswitches and vnet devices.  Normally, Solaris in the guest would enumerate network devices sequentially.  However, it has ways of remembering this initial numbering.  This is good in the physical world.  In the virtual world, whenever you unbind (aka power off and disassemble) a guest system, remove and/or add network devices and bind the system again, chances are this numbering will change.  Configuration confusion will follow suit.  To avoid this, nail down the initial numbering by assigning each vnet device it's device-id explicitly: root@sun # ldm add-vnet admin-net id=1 admin-vsw venus Please consult the Admin Guide for details on this, and how to decipher these network ids from Solaris running in the guest. Thanks for reading this far.  Links for further reading are essentially only the Admin Guide and Reference Manual and can be found above.  I hope this is useful and, as always, I welcome any comments.

    Read the article

  • Upload Certificate and Key to RUEI in order to decrypt SSL traffic

    - by stefan.thieme(at)oracle.com
    So you want to monitor encrypted traffic with your RUEI collector ?Actually this is an easy thing if you follow the lines below...I will start out with creating a pair of snakeoil (so called self-signed) certificate and key with the make-ssl-cert tool which comes pre-packaged with apache only for the purpose of this example.$ sudo make-ssl-cert generate-default-snakeoil$ sudo ls -l /etc/ssl/certs/ssl-cert-snakeoil.pem /etc/ssl/private/ssl-cert-snakeoil.key-rw-r--r-- 1 root root     615 2010-06-07 10:03 /etc/ssl/certs/ssl-cert-snakeoil.pem-rw-r----- 1 root ssl-cert 891 2010-06-07 10:03 /etc/ssl/private/ssl-cert-snakeoil.keyRUEI Configuration of Security SSL Keys You will most likely get these two files from your Certificate Authority (CA) and/or your system administrators should be able to extract this from your WebServer or LoadBalancer handling SSL encryption for your infrastructure.Now let's look at the content of these two files, the certificate (apache assumes this is in PEM format) is called a public key and the private key is used by the apache server to encrypt traffic for a client using the certificate to initiate the SSL connection with the server.In case you already know that these two match, you simply have to paste them in one text file and upload this text file to your RUEI instance.$ sudo cat /etc/ssl/certs/ssl-cert-snakeoil.pem /etc/ssl/private/ssl-cert-snakeoil.key > /tmp/ruei.cert_and_key$ sudo cat /tmp/ruei.cert_and_key -----BEGIN CERTIFICATE----- MIIBmTCCAQICCQD7O3XXwVilWzANBgkqhkiG9w0BAQUFADARMQ8wDQYDVQQDEwZ1 YnVudHUwHhcNMTAwNjA3MDgwMzUzWhcNMjAwNjA0MDgwMzUzWjARMQ8wDQYDVQQD EwZ1YnVudHUwgZ8wDQYJKoZIhvcNAQEBBQADgY0AMIGJAoGBALbs+JnI+p+K7Iqa SQZdnYBxOpdRH0/9jt1QKvmH68v81h9+f1Z2rVR7Zrd/l+ruE3H9VvuzxMlKuMH7 qBX/gmjDZTlj9WJM+zc0tSk+e2udy9he20lGzTxv0vaykJkuKcvSWNk4WE9NuAdg IHZvjKgoTSVmvM1ApMCg69nyOy97AgMBAAEwDQYJKoZIhvcNAQEFBQADgYEAk2rv VEkxR1qPSpJiudDuGUHtWKBKWiWbmSwI3REZT+0vG+YDG5a55NdxgRk3zhQntqF7 gNYjKxblBByBpY7W0ci00kf7kFgvXWMeU96NSQJdnid/YxzQYn0dGL2rSh1dwdPN NPQlNSfnEQ1yxFevR7aRdCqTbTXU3mxi8YaSscE= -----END CERTIFICATE----- -----BEGIN RSA PRIVATE KEY----- MIICXgIBAAKBgQC27PiZyPqfiuyKmkkGXZ2AcTqXUR9P/Y7dUCr5h+vL/NYffn9W dq1Ue2a3f5fq7hNx/Vb7s8TJSrjB+6gV/4Jow2U5Y/ViTPs3NLUpPntrncvYXttJ Rs08b9L2spCZLinL0ljZOFhPTbgHYCB2b4yoKE0lZrzNQKTAoOvZ8jsvewIDAQAB AoGBAJ7LCWeeUwnKNFqBYmD3RTFpmX4furnal3lBDX0945BZtJr0WZ/6N679zIYA aiVTdGfgjvDC9lHy3n3uctRd0Jqdh2QoSSxNBhq5elIApNIIYzu7w/XI/VhGcDlA b6uadURQEC2q+M8YYjw3mwR2omhCWlHIViOHe/9T8jfP/8pxAkEA7k39WRcQildH DFKcj7gurqlkElHysacMTFWf0ZDTEUS6bdkmNXwK6mH63BlmGLrYAP5AMgKgeDf8 D+WRfv8YKQJBAMSCQ7UGDN3ysyfIIrdc1RBEAk4BOrKHKtD5Ux0z5lcQkaCYrK8J DuSldreN2yOhS99/S4CRWmGkTj04wRSnjwMCQQCaR5mW3QzTU4/m1XEQxsBKSdZE 2hMSmsCmhuSyK13Kl0FPLr/C7qyuc4KSjksABa8kbXaoKfUz/6LLs+ePXZ2JAkAv +mIPk5+WnQgS4XFgdYDrzL8HTpOHPSs+BHG/goltnnT/0ebvgXWqa5+1pyPm6h29 PrYveM2pY1Va6z1xDowDAkEAttfzAwAHz+FUhWQCmOBpvBuW/KhYWKZTMpvxFMSY YD5PH6NNyLfBx0J4nGPN5n/f6il0s9pzt3ko++/eUtWSnQ== -----END RSA PRIVATE KEY----- Simply click on the add new key and browse for the cert_and_key file on your desktop which you concatenated earlier using any text editor. You may need to add a passphrase in order to decrypt the RSA key in some cases (it should tell you BEGIN ENCRYPTED PRIVATE KEY in the header line). I will show you the success screen after uploading the certificate to RUEI. You may want to restart your collector once you have uploaded all the certificate/key pairs you want to use in order to make sure they get picked up asap.You should be able to see the number of SSL Connections rising in the Collector statistics screen below. The figures for decrypt errors should slowly go down and the usage figures for your encryption algortihm on the subsequent SSL Encryption screen should go up. You should be 100% sure everything works fine by now, otherwise see below to distinguish the remaining 1% from your 99% certainty.Verify Certificate and Key are matchingYou can compare the modulus of private key and public certificate and they should match in order for the key to fit the lock. You only want to make sure they both fit each other.We are actually interested only in the following details of the two files, which can be determined by using the -subject, -dates and -modulus command line switches instead of the complete -text output of the x509 certificate/rsa key contents.$ sudo openssl x509 -noout -subject -in /etc/ssl/certs/ssl-cert-snakeoil.pemsubject= /CN=ubuntu$ sudo openssl x509 -noout -dates -in /etc/ssl/certs/ssl-cert-snakeoil.pemnotBefore=Jun  7 08:03:53 2010 GMTnotAfter=Jun  4 08:03:53 2020 GMT$ sudo openssl x509 -noout -modulus -in /etc/ssl/certs/ssl-cert-snakeoil.pem Modulus=B6ECF899C8FA9F8AEC8A9A49065D9D80713A97511F4FFD8EDD502AF987EBCBFCD61F7E7F5676AD547B66B77F97EAEE1371FD56FBB3C4C94AB8C1FBA815FF8268C3653963F5624CFB3734B5293E7B6B9DCBD85EDB4946CD3C6FD2F6B290992E29CBD258D938584F4DB8076020766F8CA8284D2566BCCD40A4C0A0EBD9F23B2F7B $ sudo openssl rsa -noout -modulus -in /etc/ssl/private/ssl-cert-snakeoil.keyModulus=B6ECF899C8FA9F8AEC8A9A49065D9D80713A97511F4FFD8EDD502AF987EBCBFCD61F7E7F5676AD547B66B77F97EAEE1371FD56FBB3C4C94AB8C1FBA815FF8268C3653963F5624CFB3734B5293E7B6B9DCBD85EDB4946CD3C6FD2F6B290992E29CBD258D938584F4DB8076020766F8CA8284D2566BCCD40A4C0A0EBD9F23B2F7BAs you can see the modulus matches exactly and we have the proof that the certificate has been created using the private key. OpenSSL Certificate and Key DetailsAs I already told you, you do not need all the greedy details, but in case you want to know it in depth what is actually in those hex-blocks can be made visible with the following commands which show you the actual content in a human readable format.Note: You may not want to post all the details of your private key =^) I told you I have been using a self-signed certificate only for showing you these details.$ sudo openssl rsa -noout -text -in /etc/ssl/private/ssl-cert-snakeoil.keyPrivate-Key: (1024 bit)modulus:    00:b6:ec:f8:99:c8:fa:9f:8a:ec:8a:9a:49:06:5d:    9d:80:71:3a:97:51:1f:4f:fd:8e:dd:50:2a:f9:87:    eb:cb:fc:d6:1f:7e:7f:56:76:ad:54:7b:66:b7:7f:    97:ea:ee:13:71:fd:56:fb:b3:c4:c9:4a:b8:c1:fb:    a8:15:ff:82:68:c3:65:39:63:f5:62:4c:fb:37:34:    b5:29:3e:7b:6b:9d:cb:d8:5e:db:49:46:cd:3c:6f:    d2:f6:b2:90:99:2e:29:cb:d2:58:d9:38:58:4f:4d:    b8:07:60:20:76:6f:8c:a8:28:4d:25:66:bc:cd:40:    a4:c0:a0:eb:d9:f2:3b:2f:7bpublicExponent: 65537 (0x10001)privateExponent:    00:9e:cb:09:67:9e:53:09:ca:34:5a:81:62:60:f7:    45:31:69:99:7e:1f:ba:b9:da:97:79:41:0d:7d:3d:    e3:90:59:b4:9a:f4:59:9f:fa:37:ae:fd:cc:86:00:    6a:25:53:74:67:e0:8e:f0:c2:f6:51:f2:de:7d:ee:    72:d4:5d:d0:9a:9d:87:64:28:49:2c:4d:06:1a:b9:    7a:52:00:a4:d2:08:63:3b:bb:c3:f5:c8:fd:58:46:    70:39:40:6f:ab:9a:75:44:50:10:2d:aa:f8:cf:18:    62:3c:37:9b:04:76:a2:68:42:5a:51:c8:56:23:87:    7b:ff:53:f2:37:cf:ff:ca:71prime1:    00:ee:4d:fd:59:17:10:8a:57:47:0c:52:9c:8f:b8:    2e:ae:a9:64:12:51:f2:b1:a7:0c:4c:55:9f:d1:90:    d3:11:44:ba:6d:d9:26:35:7c:0a:ea:61:fa:dc:19:    66:18:ba:d8:00:fe:40:32:02:a0:78:37:fc:0f:e5:    91:7e:ff:18:29prime2:    00:c4:82:43:b5:06:0c:dd:f2:b3:27:c8:22:b7:5c:    d5:10:44:02:4e:01:3a:b2:87:2a:d0:f9:53:1d:33:    e6:57:10:91:a0:98:ac:af:09:0e:e4:a5:76:b7:8d:    db:23:a1:4b:df:7f:4b:80:91:5a:61:a4:4e:3d:38:    c1:14:a7:8f:03exponent1:    00:9a:47:99:96:dd:0c:d3:53:8f:e6:d5:71:10:c6:    c0:4a:49:d6:44:da:13:12:9a:c0:a6:86:e4:b2:2b:    5d:ca:97:41:4f:2e:bf:c2:ee:ac:ae:73:82:92:8e:    4b:00:05:af:24:6d:76:a8:29:f5:33:ff:a2:cb:b3:    e7:8f:5d:9d:89exponent2:    2f:fa:62:0f:93:9f:96:9d:08:12:e1:71:60:75:80:    eb:cc:bf:07:4e:93:87:3d:2b:3e:04:71:bf:82:89:    6d:9e:74:ff:d1:e6:ef:81:75:aa:6b:9f:b5:a7:23:    e6:ea:1d:bd:3e:b6:2f:78:cd:a9:63:55:5a:eb:3d:    71:0e:8c:03coefficient:    00:b6:d7:f3:03:00:07:cf:e1:54:85:64:02:98:e0:    69:bc:1b:96:fc:a8:58:58:a6:53:32:9b:f1:14:c4:    98:60:3e:4f:1f:a3:4d:c8:b7:c1:c7:42:78:9c:63:    cd:e6:7f:df:ea:29:74:b3:da:73:b7:79:28:fb:ef:    de:52:d5:92:9d$ sudo openssl x509 -noout -text -in /etc/ssl/certs/ssl-cert-snakeoil.pemCertificate:    Data:        Version: 1 (0x0)        Serial Number:            fb:3b:75:d7:c1:58:a5:5b        Signature Algorithm: sha1WithRSAEncryption        Issuer: CN=ubuntu        Validity            Not Before: Jun  7 08:03:53 2010 GMT            Not After : Jun  4 08:03:53 2020 GMT        Subject: CN=ubuntu        Subject Public Key Info:            Public Key Algorithm: rsaEncryption            RSA Public Key: (1024 bit)                Modulus (1024 bit):                    00:b6:ec:f8:99:c8:fa:9f:8a:ec:8a:9a:49:06:5d:                    9d:80:71:3a:97:51:1f:4f:fd:8e:dd:50:2a:f9:87:                    eb:cb:fc:d6:1f:7e:7f:56:76:ad:54:7b:66:b7:7f:                    97:ea:ee:13:71:fd:56:fb:b3:c4:c9:4a:b8:c1:fb:                    a8:15:ff:82:68:c3:65:39:63:f5:62:4c:fb:37:34:                    b5:29:3e:7b:6b:9d:cb:d8:5e:db:49:46:cd:3c:6f:                    d2:f6:b2:90:99:2e:29:cb:d2:58:d9:38:58:4f:4d:                    b8:07:60:20:76:6f:8c:a8:28:4d:25:66:bc:cd:40:                    a4:c0:a0:eb:d9:f2:3b:2f:7b                Exponent: 65537 (0x10001)    Signature Algorithm: sha1WithRSAEncryption        93:6a:ef:54:49:31:47:5a:8f:4a:92:62:b9:d0:ee:19:41:ed:        58:a0:4a:5a:25:9b:99:2c:08:dd:11:19:4f:ed:2f:1b:e6:03:        1b:96:b9:e4:d7:71:81:19:37:ce:14:27:b6:a1:7b:80:d6:23:        2b:16:e5:04:1c:81:a5:8e:d6:d1:c8:b4:d2:47:fb:90:58:2f:        5d:63:1e:53:de:8d:49:02:5d:9e:27:7f:63:1c:d0:62:7d:1d:        18:bd:ab:4a:1d:5d:c1:d3:cd:34:f4:25:35:27:e7:11:0d:72:        c4:57:af:47:b6:91:74:2a:93:6d:35:d4:de:6c:62:f1:86:92:        b1:c1The above output can also be seen if you direct your browser client to your website and check the certificate sent by the server to your browser. You will be able to lookup all the details including the validity dates, subject common name and the public key modulus.Capture an SSL connection using WiresharkAnd as you would have expected, looking at the low-level tcp data that has been exchanged between the client and server with a tcp-diagnostics tool (i.e. wireshark/tcpdump) you can also see the modulus in there.These were the settings I used to capture all traffic on the local loopback interface, matching the filter expression: tcp and ip and host 127.0.0.1 and port 443. This tells Wireshark to leave out any other information, I may not have been interested in showing you.

    Read the article

  • What's up with LDoms: Part 1 - Introduction & Basic Concepts

    - by Stefan Hinker
    LDoms - the correct name is Oracle VM Server for SPARC - have been around for quite a while now.  But to my surprise, I get more and more requests to explain how they work or to give advise on how to make good use of them.  This made me think that writing up a few articles discussing the different features would be a good idea.  Now - I don't intend to rewrite the LDoms Admin Guide or to copy and reformat the (hopefully) well known "Beginners Guide to LDoms" by Tony Shoumack from 2007.  Those documents are very recommendable - especially the Beginners Guide, although based on LDoms 1.0, is still a good place to begin with.  However, LDoms have come a long way since then, and I hope to contribute to their adoption by discussing how they work and what features there are today.  In this and the following posts, I will use the term "LDoms" as a common abbreviation for Oracle VM Server for SPARC, just because it's a lot shorter and easier to type (and presumably, read). So, just to get everyone on the same baseline, lets briefly discuss the basic concepts of virtualization with LDoms.  LDoms make use of a hypervisor as a layer of abstraction between real, physical hardware and virtual hardware.  This virtual hardware is then used to create a number of guest systems which each behave very similar to a system running on bare metal:  Each has its own OBP, each will install its own copy of the Solaris OS and each will see a certain amount of CPU, memory, disk and network resources available to it.  Unlike some other type 1 hypervisors running on x86 hardware, the SPARC hypervisor is embedded in the system firmware and makes use both of supporting functions in the sun4v SPARC instruction set as well as the overall CPU architecture to fulfill its function. The CMT architecture of the supporting CPUs (T1 through T4) provide a large number of cores and threads to the OS.  For example, the current T4 CPU has eight cores, each running 8 threads, for a total of 64 threads per socket.  To the OS, this looks like 64 CPUs.  The SPARC hypervisor, when creating guest systems, simply assigns a certain number of these threads exclusively to one guest, thus avoiding the overhead of having to schedule OS threads to CPUs, as do typical x86 hypervisors.  The hypervisor only assigns CPUs and then steps aside.  It is not involved in the actual work being dispatched from the OS to the CPU, all it does is maintain isolation between different guests. Likewise, memory is assigned exclusively to individual guests.  Here,  the hypervisor provides generic mappings between the physical hardware addresses and the guest's views on memory.  Again, the hypervisor is not involved in the actual memory access, it only maintains isolation between guests. During the inital setup of a system with LDoms, you start with one special domain, called the Control Domain.  Initially, this domain owns all the hardware available in the system, including all CPUs, all RAM and all IO resources.  If you'd be running the system un-virtualized, this would be what you'd be working with.  To allow for guests, you first resize this initial domain (also called a primary domain in LDoms speak), assigning it a small amount of CPU and memory.  This frees up most of the available CPU and memory resources for guest domains.  IO is a little more complex, but very straightforward.  When LDoms 1.0 first came out, the only way to provide IO to guest systems was to create virtual disk and network services and attach guests to these services.  In the meantime, several different ways to connect guest domains to IO have been developed, the most recent one being SR-IOV support for network devices released in version 2.2 of Oracle VM Server for SPARC. I will cover these more advanced features in detail later.  For now, lets have a short look at the initial way IO was virtualized in LDoms: For virtualized IO, you create two services, one "Virtual Disk Service" or vds, and one "Virtual Switch" or vswitch.  You can, of course, also create more of these, but that's more advanced than I want to cover in this introduction.  These IO services now connect real, physical IO resources like a disk LUN or a networt port to the virtual devices that are assigned to guest domains.  For disk IO, the normal case would be to connect a physical LUN (or some other storage option that I'll discuss later) to one specific guest.  That guest would be assigned a virtual disk, which would appear to be just like a real LUN to the guest, while the IO is actually routed through the virtual disk service down to the physical device.  For network, the vswitch acts very much like a real, physical ethernet switch - you connect one physical port to it for outside connectivity and define one or more connections per guest, just like you would plug cables between a real switch and a real system. For completeness, there is another service that provides console access to guest domains which mimics the behavior of serial terminal servers. The connections between the virtual devices on the guest's side and the virtual IO services in the primary domain are created by the hypervisor.  It uses so called "Logical Domain Channels" or LDCs to create point-to-point connections between all of these devices and services.  These LDCs work very similar to high speed serial connections and are configured automatically whenever the Control Domain adds or removes virtual IO. To see all this in action, now lets look at a first example.  I will start with a newly installed machine and configure the control domain so that it's ready to create guest systems. In a first step, after we've installed the software, let's start the virtual console service and downsize the primary domain.  root@sun # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-c-- UART 512 261632M 0.3% 2d 13h 58m root@sun # ldm add-vconscon port-range=5000-5100 \ primary-console primary root@sun # svcadm enable vntsd root@sun # svcs vntsd STATE STIME FMRI online 9:53:21 svc:/ldoms/vntsd:default root@sun # ldm set-vcpu 16 primary root@sun # ldm set-mau 1 primary root@sun # ldm start-reconf primary root@sun # ldm set-memory 7680m primary root@sun # ldm add-config initial root@sun # shutdown -y -g0 -i6 So what have I done: I've defined a range of ports (5000-5100) for the virtual network terminal service and then started that service.  The vnts will later provide console connections to guest systems, very much like serial NTS's do in the physical world. Next, I assigned 16 vCPUs (on this platform, a T3-4, that's two cores) to the primary domain, freeing the rest up for future guest systems.  I also assigned one MAU to this domain.  A MAU is a crypto unit in the T3 CPU.  These need to be explicitly assigned to domains, just like CPU or memory.  (This is no longer the case with T4 systems, where crypto is always available everywhere.) Before I reassigned the memory, I started what's called a "delayed reconfiguration" session.  That avoids actually doing the change right away, which would take a considerable amount of time in this case.  Instead, I'll need to reboot once I'm all done.  I've assigned 7680MB of RAM to the primary.  That's 8GB less the 512MB which the hypervisor uses for it's own private purposes.  You can, depending on your needs, work with less.  I'll spend a dedicated article on sizing, discussing the pros and cons in detail. Finally, just before the reboot, I saved my work on the ILOM, to make this configuration available after a powercycle of the box.  (It'll always be available after a simple reboot, but the ILOM needs to know the configuration of the hypervisor after a power-cycle, before the primary domain is booted.) Now, lets create a first disk service and a first virtual switch which is connected to the physical network device igb2. We will later use these to connect virtual disks and virtual network ports of our guest systems to real world storage and network. root@sun # ldm add-vds primary-vds root@sun # ldm add-vswitch net-dev=igb2 switch-primary primary You are free to choose whatever names you like for the virtual disk service and the virtual switch.  I strongly recommend that you choose names that make sense to you and describe the function of each service in the context of your implementation.  For the vswitch, for example, you could choose names like "admin-vswitch" or "production-network" etc. This already concludes the configuration of the control domain.  We've freed up considerable amounts of CPU and RAM for guest systems and created the necessary infrastructure - console, vts and vswitch - so that guests systems can actually interact with the outside world.  The system is now ready to create guests, which I'll describe in the next section. For further reading, here are some recommendable links: The LDoms 2.2 Admin Guide The "Beginners Guide to LDoms" The LDoms Information Center on MOS LDoms on OTN

    Read the article

  • Enable remote VNC from the commandline?

    - by Stefan Lasiewski
    I have one computer running Ubuntu 10.04, and is running Vino, the default VNC server. I have a second Windows box which is running a VNC client, but does not have any X11 capabilities. I am ssh'd into the Ubuntu host from the Windows host, but I forgot to enable VNC access on the Ubuntu host. On the Ubuntu host, is there a way for me to enable VNC connections from the Ubuntu commandline? Update: As @koanhead says below, there is no man page for vino (e.g. man -k vino and info vino return nothing), and vino --help doesn't show any help).

    Read the article

  • Referencing environment variables *in* /etc/environment?

    - by Stefan Kendall
    I recently discovered /etc/environment, which seems a more standard way to setup simple environment variables than scripts, but I was wondering if there was a way to back-reference environment variables in the /etc/environment file. That is, I have this: JAVA_HOME="/tools/java" GRAILS_HOME="/tools/grails" GROOVY_HOME="/tools/groovy" GRADLE_HOME="/tools/gradle" PATH="/usr/local/sbin:/usr/local/bin:/usr/sbin:/usr/bin:/sbin:/bin:/usr/games" If I try to add $JAVA_HOME/bin to the PATH definition, however, I get $JAVA_HOME/bin, and not the interpolated variable. To remedy this, I'm creating environment.sh in profile.d to add the /bin entries to the path, but this seems sloppy and disorganized. Is there a way to backreference the environment variables in /etc/environment?

    Read the article

  • Portal And Content - Content Integration - Best Practices

    - by Stefan Krantz
    Lately we have seen an increase in projects that have failed to either get user friendly content integration or non satisfactory performance. Our intention is to mitigate any knowledge gap that our previous post might have left you with, therefore this post will repeat some recommendation or reference back to old useful post. Moreover this post will help you understand ground up how to design, architect and implement business enabled, responsive and performing portals with complex requirements on business centric information publishing. Design the Information Model The key to successful portal deployments is Information modeling, it's a key task to understand the use case you designing for, therefore I have designed a set of question you need to ask yourself or your customer: Question: Who will own the content, IT or Business? Answer: BusinessQuestion: Who will publish the content, IT or Business? Answer: BusinessQuestion: Will there be multiple publishers? Answer: YesQuestion: Are the publishers computer scientist?Answer: NoQuestion: How often do the information changes, daily, weekly, monthly?Answer: Daily, weekly If your answers to the questions matches at least 2, we strongly recommend you design your content with following principles: Divide your pages in to logical sections, where each section is marked with its purpose Assign capabilities to each section, does it contain text, images, formatting and/or is it static and is populated through other contextual information Select editor/design element type WYSIWYG - Rich Text Plain Text - non-format text Image - Image object Static List - static list of formatted informationDynamic Data List - assembled information from multiple data files through CMIS query The result of such design map could look like following below examples: Based on the outcome of the required elements in the design column 3 from the left you will now simply design a data model in WebCenter Content - Site Studio by creating a Region Definition structure matching your design requirements.For more information on how to create a Region definition see following post: Region Definition Post - note see instruction 7 for details. Each region definition can now be used to instantiate data files, a data file will hold the actual data for each element in the region definition. Another way you can see this is to compare the region definition as an extension to the metadata model in WebCenter Content for each data file item. Design content templates With a solid dependable information model we can now proceed to template creation and page design, in this phase focuses on how to place the content sections from the region definition on the page via a Content Presenter template. Remember by creating content presenter templates you will leverage the latest and most integrated technology WebCenter has to offer. This phase is much easier since the you already have the information model and design wire-frames to base the logic on, however there is still few considerations to pay attention to: Base the template on ADF and make only necessary exceptions to markup when required Leverage ADF design components for Tabs, Accordions and other similar components, this way the design in the content published areas will comply with other design areas based on custom ADF taskflows There is no performance impact when using meta data or region definition based data All data access regardless of type, metadata or xml data it can be accessed via the Content Presenter - Node. See below for applied examples on how to access data Access metadata property from Document - #{node.propertyMap['myProp'].value}myProp in this example can be for instance (dDocName, dDocTitle, xComments or any other available metadata) Access element data from data file xml - #{node.propertyMap['[Region Definition Name]:[Element name]'].asTextHtml}Region Definition Name is the expect region definition that the current data file is instantiatingElement name is the element value you like to grab from the data file I recommend you read following  useful post on content template topic:CMIS queries and template creation - note see instruction 9 for detailsStatic List template rendering For more information on templates:Single Item Content TemplateMulti Item Content TemplateExpression Language Internationalization Considerations When integrating content assets via content presenter you by now probably understand that the content item/data file is wired to the page, what is also pretty common at this stage is that the content item/data file only support one language since its not practical or business friendly to mix that into a complex structure. Therefore you will be left with a very common dilemma that you will have to either build a complete new portal for each locale, which is not an good option! However with little bit of information modeling and clear naming convention this can be addressed. Basically you can simply make sure that all content item/data file are named with a predictable naming convention like "Content1_EN" for the English rendition and "Content1_ES" for the Spanish rendition. This way through simple none complex customizations you will be able to dynamically switch the actual content item/data file just before rendering. By following proposed approach above you not only enable a simple mechanism for internationalized content you also preserve the functionality in the content presenter to support business accessible run-time publishing of information on existing and new pages. I recommend you read following useful post on Internationalization topics:Internationalize with Content Presenter Integrate with Review & Approval processes Today the Review and approval functionality and configuration is based out of WebCenter Content - Criteria Workflows. Criteria Workflows uses the metadata of the checked in document to evaluate if the document is under any review/approval process. So for instance if a Criteria Workflow is configured to force any documents with Version = "2" or "higher" and Content Type is "Instructions", any matching content item version on check in will now enter the workflow before getting released for general access. Few things to consider when configuring Criteria Workflows: Make sure to not trigger on version one for Content Items that are Data Files - if you trigger on version 1 you will not only approve an empty document you will also have a content presenter pointing to a none existing document - since the document will only be available after successful completion of the workflow Approval workflows sometimes requires more complex criteria, the recommendation if that is the case is that the meta data triggering such criteria is automatically populated, this can be achieved through many approaches including Content Profiles Criteria workflows are configured and managed in WebCenter Content Administration Applets where you can configure one or more workflows. When you configured Criteria workflows the Content Presenter will support the editors with the approval process directly inline in the "Contribution mode" of the portal. In addition to approve/reject and details of the task, the content presenter natively support the user to view the current and future version of the change he/she is approving. See below for example: Architectural recommendation To support review&approval processes - minimize the amount of data files per page Each CMIS query can consume significant time depending on the complexity of the query - minimize the amount of CMIS queries per page Use Content Presenter Templates based on ADF - this way you minimize the design considerations and optimize the usage of caching Implement the page in as few Data files as possible - simplifies publishing process, increases performance and simplifies release process Named data file (node) or list of named nodes when integrating to pages increases performance vs. querying for data Named data file (node) or list of named nodes when integrating to pages enables business centric page creation and publishing and reduces the need for IT department interaction Summary Just because one architectural decision solves a business problem it doesn't mean its the right one, when designing portals all architecture has to be in harmony and not impacting each other. For instance the most technical complex solution is not always the best since it will most likely defeat the business accessibility, performance or both, therefore the best approach is to first design for simplicity that even a non-technical user can operate, after that consider the performance impact and final look at the technology challenges these brings and workaround them first with out-of-the-box features, after that design and develop functions to complement the short comings.

    Read the article

  • What's up with LDoms: Part 2 - Creating a first, simple guest

    - by Stefan Hinker
    Welcome back! In the first part, we discussed the basic concepts of LDoms and how to configure a simple control domain.  We saw how resources were put aside for guest systems and what infrastructure we need for them.  With that, we are now ready to create a first, very simple guest domain.  In this first example, we'll keep things very simple.  Later on, we'll have a detailed look at things like sizing, IO redundancy, other types of IO as well as security. For now,let's start with this very simple guest.  It'll have one core's worth of CPU, one crypto unit, 8GB of RAM, a single boot disk and one network port.  CPU and RAM are easy.  The network port we'll create by attaching a virtual network port to the vswitch we created in the primary domain.  This is very much like plugging a cable into a computer system on one end and a network switch on the other.  For the boot disk, we'll need two things: A physical piece of storage to hold the data - this is called the backend device in LDoms speak.  And then a mapping between that storage and the guest domain, giving it access to that virtual disk.  For this example, we'll use a ZFS volume for the backend.  We'll discuss what other options there are for this and how to chose the right one in a later article.  Here we go: root@sun # ldm create mars root@sun # ldm set-vcpu 8 mars root@sun # ldm set-mau 1 mars root@sun # ldm set-memory 8g mars root@sun # zfs create rpool/guests root@sun # zfs create -V 32g rpool/guests/mars.bootdisk root@sun # ldm add-vdsdev /dev/zvol/dsk/rpool/guests/mars.bootdisk \ mars.root@primary-vds root@sun # ldm add-vdisk root mars.root@primary-vds mars root@sun # ldm add-vnet net0 switch-primary mars That's all, mars is now ready to power on.  There are just three commands between us and the OK prompt of mars:  We have to "bind" the domain, start it and connect to its console.  Binding is the process where the hypervisor actually puts all the pieces that we've configured together.  If we made a mistake, binding is where we'll be told (starting in version 2.1, a lot of sanity checking has been put into the config commands themselves, but binding will catch everything else).  Once bound, we can start (and of course later stop) the domain, which will trigger the boot process of OBP.  By default, the domain will then try to boot right away.  If we don't want that, we can set "auto-boot?" to false.  Finally, we'll use telnet to connect to the console of our newly created guest.  The output of "ldm list" shows us what port has been assigned to mars.  By default, the console service only listens on the loopback interface, so using telnet is not a large security concern here. root@sun # ldm set-variable auto-boot\?=false mars root@sun # ldm bind mars root@sun # ldm start mars root@sun # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-cv- UART 8 7680M 0.5% 1d 4h 30m mars active -t---- 5000 8 8G 12% 1s root@sun # telnet localhost 5000 Trying 127.0.0.1... Connected to localhost. Escape character is '^]'. ~Connecting to console "mars" in group "mars" .... Press ~? for control options .. {0} ok banner SPARC T3-4, No Keyboard Copyright (c) 1998, 2011, Oracle and/or its affiliates. All rights reserved. OpenBoot 4.33.1, 8192 MB memory available, Serial # 87203131. Ethernet address 0:21:28:24:1b:50, Host ID: 85241b50. {0} ok We're done, mars is ready to install Solaris, preferably using AI, of course ;-)  But before we do that, let's have a little look at the OBP environment to see how our virtual devices show up here: {0} ok printenv auto-boot? auto-boot? = false {0} ok printenv boot-device boot-device = disk net {0} ok devalias root /virtual-devices@100/channel-devices@200/disk@0 net0 /virtual-devices@100/channel-devices@200/network@0 net /virtual-devices@100/channel-devices@200/network@0 disk /virtual-devices@100/channel-devices@200/disk@0 virtual-console /virtual-devices/console@1 name aliases We can see that setting the OBP variable "auto-boot?" to false with the ldm command worked.  Of course, we'd normally set this to "true" to allow Solaris to boot right away once the LDom guest is started.  The setting for "boot-device" is the default "disk net", which means OBP would try to boot off the devices pointed to by the aliases "disk" and "net" in that order, which usually means "disk" once Solaris is installed on the disk image.  The actual devices these aliases point to are shown with the command "devalias".  Here, we have one line for both "disk" and "net".  The device paths speak for themselves.  Note that each of these devices has a second alias: "net0" for the network device and "root" for the disk device.  These are the very same names we've given these devices in the control domain with the commands "ldm add-vnet" and "ldm add-vdisk".  Remember this, as it is very useful once you have several dozen disk devices... To wrap this up, in this part we've created a simple guest domain, complete with CPU, memory, boot disk and network connectivity.  This should be enough to get you going.  I will cover all the more advanced features and a little more theoretical background in several follow-on articles.  For some background reading, I'd recommend the following links: LDoms 2.2 Admin Guide: Setting up Guest Domains Virtual Console Server: vntsd manpage - This includes the control sequences and commands available to control the console session. OpenBoot 4.x command reference - All the things you can do at the ok prompt

    Read the article

  • Secure Deployment of Oracle VM Server for SPARC - aktualisiert

    - by Stefan Hinker
    Vor einiger Zeit hatte ich ein Papier mit Empfehlungen fuer den sicheren Einsatz von LDoms veroeffentlicht.  In der Zwischenzeit hat sich so manche veraendert - eine Aktualisierung des Papiers wurde noetig.  Neben einigen kleineren Rechtschreibkorrekturen waren auch ettliche Links veraltet oder geandert.  Der Hauptgrund fuer eine Ueberarbeitung war jedoch das Aufkommen eines zweiten Betriebsmodels fuer LDoms.  Ein einigen wenigen kurzen Worten:  Insbesondere mit dem Erfolg der T4-4 kam es immer oefter vor, dass die Moeglichkeiten zur Hardware-Partitionierung, die diese Platform bietet, genutzt wurden.  Aehnlich wie bei den Dynamic System Domains werden dabei ganze PCIe Root-Komplexe an eine Domain vergeben.  Diese geaenderte Verwendung machte eine Behandlung in diesem Papier notwendig.  Die aktualisierte Version gibt es hier: Secure Deployment of Oracle VM Server for SPARCSecond Edition Ich hoffe, sie ist hilfreich!

    Read the article

  • automatically starting crashplan backup when a usb harddisc is connected

    - by Stefan Armbruster
    Using CrashPlan I've configured two backup sets: online backup in crashplan's cloud (this is running perfectly) a local backup on a usb harddisc directly connected to the local laptop. The USB drive is only connected rarly when being at home. When connecting the drive it mounts automatically. Is there a way to start the local backup whenever the usb disc connected. My guess is that using udev it should be possible to "somehow" tell crashplan to reevaluate the presence of backup location. Any ideas to do this?

    Read the article

  • Das T5-4 TPC-H Ergebnis naeher betrachtet

    - by Stefan Hinker
    Inzwischen haben vermutlich viele das neue TPC-H Ergebnis der SPARC T5-4 gesehen, das am 7. Juni bei der TPC eingereicht wurde.  Die wesentlichen Punkte dieses Benchmarks wurden wie gewohnt bereits von unserer Benchmark-Truppe auf  "BestPerf" zusammengefasst.  Es gibt aber noch einiges mehr, das eine naehere Betrachtung lohnt. Skalierbarkeit Das TPC raet von einem Vergleich von TPC-H Ergebnissen in unterschiedlichen Groessenklassen ab.  Aber auch innerhalb der 3000GB-Klasse ist es interessant: SPARC T4-4 mit 4 CPUs (32 Cores mit 3.0 GHz) liefert 205,792 QphH. SPARC T5-4 mit 4 CPUs (64 Cores mit 3.6 GHz) liefert 409,721 QphH. Das heisst, es fehlen lediglich 1863 QphH oder 0.45% zu 100% Skalierbarkeit, wenn man davon ausgeht, dass die doppelte Anzahl Kerne das doppelte Ergebnis liefern sollte.  Etwas anspruchsvoller, koennte man natuerlich auch einen Faktor von 2.4 erwarten, wenn man die hoehere Taktrate mit beruecksichtigt.  Das wuerde die Latte auf 493901 QphH legen.  Dann waere die SPARC T5-4 bei 83%.  Damit stellt sich die Frage: Was hat hier nicht skaliert?  Vermutlich der Plattenspeicher!  Auch hier lohnt sich eine naehere Betrachtung: Plattenspeicher Im Bericht auf BestPerf und auch im Full Disclosure Report der TPC stehen einige interessante Details zum Plattenspeicher und der Konfiguration.   In der Konfiguration der SPARC T4-4 wurden 12 2540-M2 Arrays verwendet, die jeweils ca. 1.5 GB/s Durchsatz liefert, insgesamt also eta 18 GB/s.  Dabei waren die Arrays offensichtlich mit jeweils 2 Kabeln pro Array direkt an die 24 8GBit FC-Ports des Servers angeschlossen.  Mit den 2x 8GBit Ports pro Array koennte man so ein theoretisches Maximum von 2GB/s erreichen.  Tatsaechlich wurden 1.5GB/s geliefert, was so ziemlich dem realistischen Maximum entsprechen duerfte. Fuer den Lauf mit der SPARC T5-4 wurden doppelt so viele Platten verwendet.  Dafuer wurden die 2540-M2 Arrays mit je einem zusaetzlichen Plattentray erweitert.  Mit dieser Konfiguration wurde dann (laut BestPerf) ein Maximaldurchsatz von 33 GB/s erreicht - nicht ganz das doppelte des SPARC T4-4 Laufs.  Um tatsaechlich den doppelten Durchsatz (36 GB/s) zu liefern, haette jedes der 12 Arrays 3 GB/s ueber seine 4 8GBit Ports liefern muessen.  Im FDR stehen nur 12 dual-port FC HBAs, was die Verwendung der Brocade FC Switches erklaert: Es wurden alle 4 8GBit ports jedes Arrays an die Switches angeschlossen, die die Datenstroeme dann in die 24 16GBit HBA ports des Servers buendelten.  Das theoretische Maximum jedes Storage-Arrays waere nun 4 GB/s.  Wenn man jedoch den Protokoll- und "Realitaets"-Overhead mit einrechnet, sind die tatsaechlich gelieferten 2.75 GB/s gar nicht schlecht.  Mit diesen Zahlen im Hinterkopf ist die Verdopplung des SPARC T4-4 Ergebnisses eine gute Leistung - und gleichzeitig eine gute Erklaerung, warum nicht bis zum 2.4-fachen skaliert wurde. Nebenbei bemerkt: Weder die SPARC T4-4 noch die SPARC T5-4 hatten in der gemessenen Konfiguration irgendwelche Flash-Devices. Mitbewerb Seit die T4 Systeme auf dem Markt sind, bemuehen sich unsere Mitbewerber redlich darum, ueberall den Eindruck zu hinterlassen, die Leistung des SPARC CPU-Kerns waere weiterhin mangelhaft.  Auch scheinen sie ueberzeugt zu sein, dass (ueber)grosse Caches und hohe Taktraten die einzigen Schluessel zu echter Server Performance seien.  Wenn ich mir nun jedoch die oeffentlichen TPC-H Ergebnisse ansehe, sehe ich dies: TPC-H @3000GB, Non-Clustered Systems System QphH SPARC T5-4 3.6 GHz SPARC T5 4/64 – 2048 GB 409,721.8 SPARC T4-4 3.0 GHz SPARC T4 4/32 – 1024 GB 205,792.0 IBM Power 780 4.1 GHz POWER7 8/32 – 1024 GB 192,001.1 HP ProLiant DL980 G7 2.27 GHz Intel Xeon X7560 8/64 – 512 GB 162,601.7 Kurz zusammengefasst: Mit 32 Kernen (mit 3 GHz und 4MB L3 Cache), liefert die SPARC T4-4 mehr QphH@3000GB ab als IBM mit ihrer 32 Kern Power7 (bei 4.1 GHz und 32MB L3 Cache) und auch mehr als HP mit einem 64 Kern Intel Xeon System (2.27 GHz und 24MB L3 Cache).  Ich frage mich, wo genau SPARC hier mangelhaft ist? Nun koennte man natuerlich argumentieren, dass beide Ergebnisse nicht gerade neu sind.  Nun, in Ermangelung neuerer Ergebnisse kann man ja mal ein wenig spekulieren: IBMs aktueller Performance Report listet die o.g. IBM Power 780 mit einem rPerf Wert von 425.5.  Ein passendes Nachfolgesystem mit Power7+ CPUs waere die Power 780+ mit 64 Kernen, verfuegbar mit 3.72 GHz.  Sie wird mit einem rPerf Wert von  690.1 angegeben, also 1.62x mehr.  Wenn man also annimmt, dass Plattenspeicher nicht der limitierende Faktor ist (IBM hat mit 177 SSDs getestet, sie duerfen das gerne auf 400 erhoehen) und IBMs eigene Leistungsabschaetzung zugrunde legt, darf man ein theoretisches Ergebnis von 311398 QphH@3000GB erwarten.  Das waere dann allerdings immer noch weit von dem Ergebnis der SPARC T5-4 entfernt, und gerade in der von IBM so geschaetzen "per core" Metric noch weniger vorteilhaft. In der x86-Welt sieht es nicht besser aus.  Leider gibt es von Intel keine so praktischen rPerf-Tabellen.  Daher muss ich hier fuer eine Schaetzung auf SPECint_rate2006 zurueckgreifen.  (Ich bin kein grosser Fan von solchen Kreuz- und Querschaetzungen.  Insb. SPECcpu ist nicht besonders geeignet, um Datenbank-Leistung abzuschaetzen, da fast kein IO im Spiel ist.)  Das o.g. HP System wird bei SPEC mit 1580 CINT2006_rate gelistet.  Das bis einschl. 2013-06-14 beste Resultat fuer den neuen Intel Xeon E7-4870 mit 8 CPUs ist 2180 CINT2006_rate.  Das ist immerhin 1.38x besser.  (Wenn man nur die Taktrate beruecksichtigen wuerde, waere man bei 1.32x.)  Hier weiter zu rechnen, ist muessig, aber fuer die ungeduldigen Leser hier eine kleine tabellarische Zusammenfassung: TPC-H @3000GB Performance Spekulationen System QphH* Verbesserung gegenueber der frueheren Generation SPARC T4-4 32 cores SPARC T4 205,792 2x SPARC T5-464 cores SPARC T5 409,721 IBM Power 780 32 cores Power7 192,001 1.62x IBM Power 780+ 64 cores Power7+  311,398* HP ProLiant DL980 G764 cores Intel Xeon X7560 162,601 1.38x HP ProLiant DL980 G780 cores Intel Xeon E7-4870    224,348* * Keine echten Resultate  - spekulative Werte auf der Grundlage von rPerf (Power7+) oder SPECint_rate2006 (HP) Natuerlich sind IBM oder HP herzlich eingeladen, diese Werte zu widerlegen.  Aber stand heute warte ich noch auf aktuelle Benchmark Veroffentlichungen in diesem Datensegment. Was koennen wir also zusammenfassen? Es gibt einige Hinweise, dass der Plattenspeicher der begrenzende Faktor war, der die SPARC T5-4 daran hinderte, auf jenseits von 2x zu skalieren Der Mythos, dass SPARC Kerne keine Leistung bringen, ist genau das - ein Mythos.  Wie sieht es umgekehrt eigentlich mit einem TPC-H Ergebnis fuer die Power7+ aus? Cache ist nicht der magische Performance-Schalter, fuer den ihn manche Leute offenbar halten. Ein System, eine CPU-Architektur und ein Betriebsystem jenseits einer gewissen Grenze zu skalieren ist schwer.  In der x86-Welt scheint es noch ein wenig schwerer zu sein. Was fehlt?  Nun, das Thema Preis/Leistung ueberlasse ich gerne den Verkaeufern ;-) Und zu guter Letzt: Nein, ich habe mich nicht ins Marketing versetzen lassen.  Aber manchmal kann ich mich einfach nicht zurueckhalten... Disclosure Statements The views expressed on this blog are my own and do not necessarily reflect the views of Oracle. TPC-H, QphH, $/QphH are trademarks of Transaction Processing Performance Council (TPC). For more information, see www.tpc.org, results as of 6/7/13. Prices are in USD. SPARC T5-4 409,721.8 QphH@3000GB, $3.94/QphH@3000GB, available 9/24/13, 4 processors, 64 cores, 512 threads; SPARC T4-4 205,792.0 QphH@3000GB, $4.10/QphH@3000GB, available 5/31/12, 4 processors, 32 cores, 256 threads; IBM Power 780 QphH@3000GB, 192,001.1 QphH@3000GB, $6.37/QphH@3000GB, available 11/30/11, 8 processors, 32 cores, 128 threads; HP ProLiant DL980 G7 162,601.7 QphH@3000GB, $2.68/QphH@3000GB available 10/13/10, 8 processors, 64 cores, 128 threads. SPEC and the benchmark names SPECfp and SPECint are registered trademarks of the Standard Performance Evaluation Corporation. Results as of June 18, 2013 from www.spec.org. HP ProLiant DL980 G7 (2.27 GHz, Intel Xeon X7560): 1580 SPECint_rate2006; HP ProLiant DL980 G7 (2.4 GHz, Intel Xeon E7-4870): 2180 SPECint_rate2006,

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >