Search Results

Search found 1864 results on 75 pages for 'raid'.

Page 30/75 | < Previous Page | 26 27 28 29 30 31 32 33 34 35 36 37  | Next Page >

  • LSI RAID-on-chip with RAID6 over two SAS links goes red when HDD enclosure is powered cycled; how to recover?

    - by GregC
    I have a RAID6 array managed by LSI 9286-8e card. I also have Sans Digital 24-bay NexentaSTOR JBOD enclosure with SAS extender built-in. They are connected to separate UPS devices. Normally, I'd shut down the PC, leaving RAID6 in healthy state. But today the power to JBOD enclosure was cut but PC kept running. After restarting the PC, all disks in RAID6 have lit up RED, and the only option in LSI MegaRAID manager app was to reset each disk to unassigned, thereby loosing all data on RAID6 array. Thankfully, I am only testing, but how would I recover if this were to happen in production?

    Read the article

  • Are FC and SAS DAS devices standard enough?

    - by user222182
    Before I ask my questions, here is some background info that may or may not be useful: For the first time I find myself needing a DAS solution. My priority is data through-put in a single direction. I can write large blocks, and I don't need to read at the same time. The server (the data producing device) is not really a typical server, its a very powerful single board computer. As such I have limited options when it comes to the add-in cards I can install since it must use the fairly uncommon interface, XMC. Currently I believe I am limited PCIex8 gen 1 which means that the likely bottle neck for me will be this 16gbps connection. XMC Boards I have found so far offer the following connections: a) Dual 10GBE ethernet controller, total throughput 20gbps b) Dual Quad SAS 2.0 Connectors (SFF-8XXX) HBA (no raid), total throughput 48 gbps c) Dual FC 8gb HBA (no raid), total throughput 16gbps My questions for you guys are: 1) Are SAS and/or FC, and by extension their HBAs, standard enough that I could purchase a Dell or Aberdeen storage server with a raid controller that has external SAS or FC ports and expect that I can connect it to my SAS or FC HBA, be presented with a single volume (if I so configured the storage server), all without having to check for HBA compatibility? 2) On a device like a Dell PowerVault (either DAS or NAS) is there an OS on it to concern myself with, or is it meant to be remotely managed? Is there a local interface in case I cant remotely manage it (i.e. if my single board computer uses an OS not supported by Dell OpenManage). Would this be true of nearly any device which calls itself a DAS? 3) If I purchase some sort of Supermicro storage chassis, installed a raid controller with external connections, is there a nice lightweight OS I can run just for management of the controller? Would I even need an OS since the raid card would be configured pre-boot anyway? 4) It is much easier to buy XMC based 10gigabit ethernet cards (generally dual port). In what ways would I be getting into trouble by using iSCSI as a DAS are direct cabling with SFP+ cables? Thanks in advance

    Read the article

  • Is a disk/ata timeout exception dangerous?

    - by j-g-faustus
    I have a few hard drives in mdadm RAID 5 configured to go to standby after a few minutes of inactivity. (Using hdparm.conf spindown_time.) At irregular intervals I get messages like these in dmesg: [ 1840.251661] ata4.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [ 1840.251722] ata4.00: failed command: SMART [ 1840.251758] ata4.00: cmd b0/d5:01:06:4f:c2/00:00:00:00:00/00 tag 0 pio 512 in [ 1840.251759] res 40/00:14:50:2e:04/00:00:02:00:00/40 Emask 0x4 (timeout) [ 1840.251858] ata4.00: status: { DRDY } [ 1840.251888] ata4: hard resetting link [ 1840.600742] ata4: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [ 1840.601521] ata4.00: configured for UDMA/133 [ 1840.601547] ata4: EH complete [337877.713988] ata4.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [337877.714019] ata4.00: failed command: SMART [337877.714038] ata4.00: cmd b0/d5:01:06:4f:c2/00:00:00:00:00/00 tag 0 pio 512 in [337877.714039] res 40/00:04:90:10:81/00:00:00:00:00/40 Emask 0x4 (timeout) [337877.714089] ata4.00: status: { DRDY } [337877.714107] ata4: hard resetting link [337878.063085] ata4: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [337878.063743] ata4.00: configured for UDMA/133 [337878.063764] ata4: EH complete I think the exception is caused by smartd when a drive does not wake up quickly enough. There are no issues (that I can tell) in accessing the drives normally through the file system - it takes a few seconds longer than normal when they are asleep, but there are no exceptions. Is this something I should worry about, as a potential symptom on something that could corrupt a drive over time? Or can I safely ignore it as part of normal operation? Edit: By request: smartctl -a for sdaand sde, both disks are members of the array. If ata4is the same as scsi-4 then sde is the one that gave the error above, according to /dev/disk/by-path.

    Read the article

  • Switching mdadm to an external bitmap

    - by Oli
    I've just read this in another post about improving RAID5/6 write speeds: After increasing stripe cache & switching to external bitmap, my speeds are 160 Mb/s writes, 260 Mb/s reads. :-D I've already found out how to increase the stripe cache and this worked pretty well but I'd like to know more about an external bitmap. I have an incredibly fast (540MB/s) RAID0 SSD that would do well if a bitmap does what I think it does but I'm still very unsure. I've only known about them as long as I've known this post. A few questions: What is a bitmap (in terms of mdadm)? What are the advantages of an internal bitmap (over external)? What are the advantages of an external bitmap (over internal)? How do I switch between the two? I should add that while this is a I'm-bored-let's-break-something thread, I do value the data stored on the RAID array. If doing this is going to put data at significant risk, please let me know.

    Read the article

  • Can't start system due to mdadm failing

    - by user101212
    I used to have a 5-disk RAID5 partition, all working very well. I have then decided to add 3 more disks on it, totaling 8 equal disks. I've opened Webmin and just asked to add the disks. Then I've realized the three disks had NTFS partitions, wich mdadm didn't complain, so I tried to stop the growing to remove the Windows partitions. I've tried to remove a disk using the same Webmin, but (as you might guess and call me fool...), the system became unstable. By restarting the system, I've started receiving these messages: "udev[126]: timeout: killing '/sbin/mdadm --incremental /dev/sdh1' [311]" "udev[124]: timeout: killing '/sbin/mdadm --detail --export /dev/md0' [316]" I've formated the system disk, hoping to get a system up and running. I did that with all RAID disks disconected, so everything was fine. I then reconnected the disks, wich was also ok. And finally installed mdadm using apt-get. By reboot, the system has found the mdadm intention of growing the system, so the same messages appear again. I other words: I can't even reach a command prompt to do something. Any ideas of what to do? I believe I could turn off the system, disconnect the disks and look for the mdadm.conf file. Would that be a good idead? I'm no Linux expert, so I'm really lost here.

    Read the article

  • Poor NFS Performance: OpenFiler

    - by Safin09
    Good Day Everyone, I have an issue with OpenFiler, a Linux-based operating that converts a computer system into a SAN/NAS appliance. Here is the problem. In my environment we have two Netapp Storevault 500 appliances that I normally perform backups to a NFS share. There are two backup cronjobs that use ghettoVCB to backup two groups of VM's. One group is a pool of 3 VMs. This takes 13 mins to complete. A second job that backups a pool of 5 VMs to a 2nd Storevault appliance which takes 2 hours. We then installed Openfiler on a old server that has 2 core Xeon processors. There is a software RAID 5 process in place. When performing the same backups to a NFS Openfiler share, the first backup job, which takes 13 mins, takes around 4 hours. The second backup job, which takes 2 hours, takes almost 10 hours to complete. This is unacceptable!!!! Especially considering the strain placed on the host ESX Server. I assumed that because of the software RAID 5, the overhead on the CPU explained the long backup times. I then installed Openfiler on a 2nd server, an IBM x306 machine which has a P4 Intel processor. This time no software RAID or any RAID at all. A single 750GB hard drive that contained the OS and the rest of the disk uses to backup VMs to a NFS share. I performed the first backup job of the pool of 3 VMs. This time the backup job took 1 and 1/2 hours to complete instead of 13 mins!!!!!!!!!! Is Openfiler simply poor at being an NFS Server!!!!!!!!!!!!! Has anyone else had these issues with Openfiler?

    Read the article

  • How to let hard drive sleep in RAID1 configuration?

    - by Al Kepp
    Normally in Windows 7 a hard drive stops spinning when it is not used for a longer while. This can be configured in Windows and I use it on computers which are turned on 24/7 but not used much often. My problem is on a computer with Intel X79 chipset with an integrated RAID controller. There is Windows 7 installed on an SSD drive, and there is RAID1 array with two SATA HDD drives for data. Those SATA drives aren't used much so I'd like to let them sleep (i.e stop spinning). But they ignore settings in Windows. How to let them sleep when using RAID1? It seems to me that those drives are "unstoppable", they are spinning 24/7 even when they aren't used at all. Maybe they would behave normally if I used Windows-based software RAID, but I use hardware RAID controller. Is there a way to let them stop spinning and sleep after for example 3 or 5 hours of inactivity (i.e. the same way as they would behave in Windows without RAID)?

    Read the article

  • Can't access my accelerated hard disk from msdos after installing linux on ssd cache

    - by Chibueze Opata
    I mistakenly installed Linux Mint on my ssd (forgot my PC actually came with one), when it detected a ~31GiB disk that it wanted to install to, I was a bit confused since I had brought out 30Gb in my primary disk for it, but I clicked continue. After installation, I tried to boot back into my Windows and it brought out some Intel Raid Disk Utility stuff saying I should disable acceleration on a disk something couldn't be found, I canceled it but whatever I tried, recovery tools, setups etc, I couldn't just access the drive which was apparently using the SSD as cache. Since then I've been stuck. I tried setting the 'raid' flag to the disk from 'gParted', still I couldn't. I tried the diskraid utility from windows recover disk, it said it couldn't detect any raid, diskpart sees the partition but doesn't see the volume, when I remove the raid flag, it sees the volume as one of raw type, and I can't access anything. I can however mount the drive from terminal in Mint and access my files, but I don't have any backup media at the moment so I can do a factory re-install. Please how do I go about solving the issue, precisely I would like to know how to boot into the drive again. Thanks!

    Read the article

  • Windows XP corrupts registry every several hours

    - by Ilya Kazakevich
    There is a Dell XPS 400 with Windows Media Center installer. It is installed on RAID (Intel Matrix Storage) which is built-in chipset south bridge. Raid has two 150 Gb WDC drivers connected as mirror. All drivers and updates are installed( sp3 and so on). A week ago PC changed its video mode to 256 colors (like VESA mode) and after several moments I got BSOD: c000021a: 0xc0000005 Doctor watson did not create dump although it is installed as default debugger. After reboot it said that config file is missing or corrupted. So, I boot to recovery console and found that registry file (config) is so small. I've replaced it with one from recovery point and windows booted sucessfully. But after about 3 hrs -- it has crashed again in the same wat! I look in event viewer: is said that Explorer.exe failed to open \global??\DLIAFS. I look in winobj, and found that it is a device. I made "deny from everyone" for this device ACL, and after several hours my windows crashed. I restored registry, boot again and there was no error about DLIAFS. I did full chkdsk and it did not found anything bad. But I found event about error paging to \Harddrive1\D. I do not have pagefile there, but I thought I should check my disk again. Unfortunatelly I cannt use smart tools for RAID, but I downloaded latest software from Intel (it can do the same things like RAID bios can but from windows). It verified my disks, found some errors, fix them, than I rebooted. And it crashed again. I am lost. What (except kernel debugging) could be done here? Thanks

    Read the article

  • Windows XP corrupts registry every several hours

    - by Ilya Kazakevich
    There is a Dell XPS 400 with Windows Media Center installer. It is installed on RAID (Intel Matrix Storage) which is built-in chipset south bridge. Raid has two 150 Gb WDC drivers connected as mirror. All drivers and updates are installed( sp3 and so on). A week ago PC changed its video mode to 256 colors (like VESA mode) and after several moments I got BSOD: c000021a: 0xc0000005 Doctor watson did not create dump although it is installed as default debugger. After reboot it said that config file is missing or corrupted. So, I boot to recovery console and found that registry file (config) is so small. I've replaced it with one from recovery point and windows booted sucessfully. But after about 3 hrs -- it has crashed again in the same wat! I look in event viewer: is said that Explorer.exe failed to open \global??\DLIAFS. I look in winobj, and found that it is a device. I made "deny from everyone" for this device ACL, and after several hours my windows crashed. I restored registry, boot again and there was no error about DLIAFS. I did full chkdsk and it did not found anything bad. But I found event about error paging to \Harddrive1\D. I do not have pagefile there, but I thought I should check my disk again. Unfortunatelly I cannt use smart tools for RAID, but I downloaded latest software from Intel (it can do the same things like RAID bios can but from windows). It verified my disks, found some errors, fix them, than I rebooted. And it crashed again. I am lost. What (except kernel debugging) could be done here? Thanks

    Read the article

  • My Computer hangs for a few minutes just after startup, and then is fine.

    - by EvilChookie
    So I just built myself a reasonably beefy computer, and I installed Windows 7 on it. However, I start the machine up each morning and within a few minutes, the computer will semi hang. That is the mouse is responsive, and most of the time I can open task manager, or a new tab in Chrome. Occasionally windows will be labelled as 'Not responding'. Then, the machine will get over it's problem, and will be nice and quick until I turn it off. Here's my specs: CPU: AMD Phenom-II X4 955 Black (Quad Core, 3.2ghz) RAM: 4GB of DDR3 1300 MOBO: ASUS M4A785T-M (Latest BIOS) HARD DRIVES: 2x1TB Western Digital Caviar Blacks in RAID-0. OS: Windows 7 Ultimate x64. GPU: ASUS GT240 1GB. I believe this issue relates to the RAID array, as I didn't have the lockup problem before I created the array. I purchased a second drive and reformatted after creating a RAID array, since the single drive was a little on the pokey side (compared to the rest of the computer). What I have tried: Updated Raid Drivers Malware checks Windows Updates Unecessary Services CPU and Disk activity appears to be low (via Resource Monitor) No strange errors in the error log. Any thoughts?

    Read the article

  • Windows 8 x64 with VMWare Workstation or inside ESXi

    - by Dommer
    I need to run several virtual machines on a core i7-920 box with 12GB or RAM and a 256GB SSD to host the VMs. It also has a Highpoint RocketRaid 2720SGL RAID controller with a 12TB RAID 5 array. I want one of my VMs to run Windows 8 x64, to have access to the RAID array as a native disk (not as networked drives and it needs to run at full speed) and to be able to send files quickly across the network. Initially I thought I'd try to do this using ESXi 5, but I have been unable to find any working RAID drivers for the RR2720SGL and it is not on the HCL for ESXi 5. In light of this, I have installed Windows 8 x64 on the hardware and am thinking of installing VMWare Workstation and running my VMs inside there. I guess my questions are these: How does VMWare Workstation 9 perform compared to ESXi 5? In the real world I mean? Presumably installing Win 8 as the host OS will give me way better performance for that Win 8 machine than Win 8 running under ESXi? I should stick with Windows 8 x64 as the host OS, right? If I install a domain controller VM inside my Win 8 box and join the Win 8 machine to that domain, am I insane (I would guess the Win 8 machine wouldn't see the domain controller until it finished starting everything up, but I don't think that matters)?! is it feasible to give metrics like this and if so, what is the likely value of x? 25%? 50%? 75%? Win 8 under ESXi runs x% as fast as Win 8 installed bare metal.

    Read the article

  • FreeNas on Dell Powervault 745N: 2TB Limit?

    - by willoller
    I want to purchase 2 x 2TB drives, and install FreeNas on my Dell Powervault 745N. People on the internets seem to be having trouble with the MD3000 firmware, and I want to make sure I can solve any issues before buying the drives. Before I invest, I have 3 questions : Is there a partition size limit determined by the RAID controller? That is, could I have a striped 4TB partition? The spec sheets make me wonder if the RAID controller needs all 4 drives in order to work. Is there any reason this will have to run in RAID5? If I buy 4 matching drives, would the controller support a RAID6 configuration? I'm basically new to all this RAID stuff - sorry for any noob questions.

    Read the article

  • Is There Anyway to Undo a Quick Initialize from a Perc6/i VD?

    - by Carlo71
    I stupidly fast initialized an existing Raid 5 Array Virtual disk with 10 Virtual Machines after creating a new Raid 5 Array. The VDs switched order on the list of the Perc Controller. My server is a PowerEdge R710 with a Perc 6/i Raid controller running ESXi 5.1. The Bios of the R710 and the Perc 6/i controller are both running the latest firmware. I tried the steps on this article: http://www.caseyfulton.com/dell-perc-6i-fast-initialize-how-to-restore/. However the BartPE just freezes on the Windows XP slapsh page. Does anybody know a full proof method? I have backups of the VMs, however I would like to avoid restoring all of them due to time constraint.

    Read the article

  • RAID1 rebuild fails due to disk errors

    - by overlord_tm
    Quick info: Dell R410 with 2x500GB drives in RAID1 on H700 Adapter Recently one of drives in RAID1 array on server failed, lets call it Drive 0. RAID controller marked it as fault and put it offline. I replaced faulty disk with new one (same series and manufacturer, just bigger) and configured new disk as hot spare. Rebuild from Drive1 started immediately and after 1.5 hour I got message that Drive 1 failed. Server was unresponsive (kernel panic) and required reboot. Given that half hour before this error rebuild was at about 40%, I estimated that new drive is not in sync yet and tried to reboot just with Drive 1. RAID controller complained a bit about missing RAID arrays, but it found foreign RAID array on Drive 1 and I imported it. Server booted and it runs (from degraded RAID). Here is SMART data for disks. Drive 0 (the one that failed first) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1 3 Spin_Up_Time POS--K 142 142 021 - 3866 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10432 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 112 106 000 - 31 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 198 000 - 3 And Drive 1 (the drive which was reported healthy from controller until rebuild was attempted) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 35 3 Spin_Up_Time POS--K 143 143 021 - 3841 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10455 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 114 105 000 - 29 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 3 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 In extended error logs from SMART I found: Drive 0 has only one error Error 1 [0] occurred at disk power-on lifetime: 10282 hours (428 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 18 00 00 00 6a 24 20 40 00 Error: IDNF at LBA = 0x006a2420 = 6956064 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 60 00 f8 00 00 00 6a 24 20 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 18 00 60 00 00 00 6a 24 00 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 80 00 58 00 00 00 6a 23 80 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 68 00 50 00 00 00 6a 23 18 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 10 00 10 00 00 00 6a 23 00 40 00 17d+20:25:18.104 WRITE FPDMA QUEUED But Drive 1 has 883 errors. I see only few last ones and all errors I can see look like this: Error 883 [18] occurred at disk power-on lifetime: 10454 hours (435 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 01 -- 51 00 80 00 00 39 97 19 c2 40 00 Error: AMNF at LBA = 0x399719c2 = 966203842 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:57.802 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:57.779 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:55.704 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:55.681 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:53.606 READ FPDMA QUEUED Given those errors, is there any way I can rebuild RAID back, or should I make backup, shutdown server, replace disks with new ones and restore it? What about if I dd faulty disk to new one from linux running on USB/CD? Also, if anyone have more experiences, what could be causes for those errors? Crappy controller or disks? Disks are about 1 year old, but it is pretty unbelievable to me that both would die within so short timespan.

    Read the article

  • HP DL180 G6 P410 8x SATA 1TB, what is the optimal configuration?

    - by Oneiroi
    I have a HP DL180 G6 with a P410 raid controller. Presently this runs using 4x 1TB Samsung Spinpoint SATA drives, in a RAID10 configuration using default settings. I am about to add a backplane to increase the drive capacity from 4 to 12 drives, and I plan to install 4 more 1TB SATA Drives. The drives are matched and have close serial numbers (They arrived together in the Manufacturers pallet). Model HD103UJ 1000GB/7200rpm/32M Rated for 3GB/s I will also be installing RHEL 6.1 x86_64. My question is what would be the optimal RAID settings (stripe etc.) for this configuration? To recap: 8x Model HD103UJ 1000GB/7200rpm/32M Rated for 3GB/s RAID 10 configuration. Thanks in advance. Update for role: Server is to become an iscsi target for an internal openstack deployment currently underway. (Glance) Will also provide virtualisation through KVM

    Read the article

  • RAID across SAS controller ports

    - by BlueGene
    Hi, I'm managing a HP DL360 G5 machine. It has a SAS controller with two ports. Port 1 is attached to 4 drive bays and Port 2 has 2 bays. The machine currently has 3 drives connected to Port 1 with RAID 5 configuration. I'm trying to max out the bays by adding 1 disk in port 1 and 2 in port 2. Can I group those three disks(1 disk-port, 2 disks-port 2) in a RAID 5 configuration?

    Read the article

  • How to re-do the hard disks in a WD Word Book Edition II ?

    - by jfmessier
    I recently purchased a WD World Book II, a 2 TB one. I call it the "White Box". It has those 2 1TB drives, and they were in this RAID 1 config, only giving me about 1 TB. I could not delete the raid array, and I took the drives in a Linux box. But I also deleted the entire partitions of the disks, and I cannot even et the existing RAID array on this WD White Box. The drives are fine, but I cannot get them to work on the WD White Box. My goal was to get back to a real 2 TB storage space. If I cannot get those drives back in the White Box, I can re-use them elsewhere, but this would mean a waste of the firmware and network connection. After the fact, I read that, anyway, the network performance is rather poor. Thanks :-)

    Read the article

  • Clonezilla is not able to clone a RAID 1 disk

    - by Adrian
    I have a HP Server DL320 G5. There are two SATA hard disks configured as RAID 1 through HP embedded RAID controller. Server OS is running GNU/Linux (Fedora) Server booted up with clonezilla live CD. The image will be stored on a NAS connected through NFS. Clonezilla could mount the NFS share and could see the two hard disks /dev/sda and /dev/sdb. I selected /dev/sda for disk cloning. However I could not see the cloning progress and got straight into a prompt for reboot, poweroff, command line I tried to select /dev/sdb but the same issue.

    Read the article

  • Strange performance from RAID5 using WD RE4 disks

    - by Howard
    I've noticed a bit of a performance issue with some WD RE4 drives I'm using under AMD's hardware RAID solution. First a bit of background: Environment: Windows 7 home premium x64 HDD's: 3x 1TB WD Raid Edition 4 in a RAID 5 setup with 128 kbyte stripe (2TB usable space) Testing Tool: HD Tune, process set to "High Priority" Processor: AMD Phenom II x6 1100T Ram: 16GB DDR3/1600mhz Motherboard: MSI 970A-G45 The image below pretty much depicts the issue I'm having. Every test has the same thing, a period of similar length where the performance drops to a few megabytes a second. This can't be a TLER issue as the purpose of RE4's is to work around that. Any help would be greatly appreciated.

    Read the article

  • Server 2008 R2 - Boot disk RAID 1 - migrate to larger disk

    - by William Hooper
    My group inherited several 2008 R2 servers with single 70GB RAID 1 boot/system disks. No other disks in the servers. We need larger boot / system disk. Plan is : to replace one disk with new 500 GB drive wait for resync replace other smaller disk with 2nd 500 GB drive wait for resysnc Now I should have 500 GB RAID 1 with original 70 GB partition Then I would like to extend the 70 GB partition to 200 GB and add D: drive partition with remaining 300 GB Can the above be done using Windows Disk Management and / or Windows DiskPart ?

    Read the article

  • SATA drive not recognized when installing RHEL 5.1 on PowerEdge R410

    - by Rachel
    Here's my setup: Dell R410 with Perc S100 (software) raid controller on an Intel ICH10R chipset The first problem is that the Perc S100 is only supported on windows. I'm trying to install RHEL 5.1. It boots from the cdrom, but later the installer can't see the cdrom or hard drive. Both are connected to the on-board sata controller. The only options in the R410 bios for SATA are ATA or RAID. I don't need raid, I just want a single drive setup.

    Read the article

  • File corruption when copying different file on raid 1

    - by Stephan
    I have a RAID 1 configuration of 2 1TB drives on a Fedora 12 box. Most of what is stored there are video files that are numerical labeled. The problem I'm having is that I had one of the video files get corrupted. I copied a replacement from a backup and replaced the bad file and now it works fine. However, after doing this the next numbered file goes from 350MB to 200KB and all but about .5 second of video disappears. If I then replace that file it happens to the next one down the line. Ex: Replace corrupt file 1.avi and file 2.avi shrinks to 200KB. Replace now corrupted 2.avi and it works but 3.avi gets screwed up. I have run SMART tests on the drives and they report fine. Does anyone have any tests I can run to try to figure out what is going on? EDIT: It is a two disk software RAID 1 with an ext4 filesystem

    Read the article

  • LVM mirroring VS RAID1

    - by syrenity
    Hi. Having learned a bit about LVM mirroring, I thought about replacing the current RAID-1 scheme I'm using to gain some flexibility. Problem is that according to what I found on the Internet, LVM is: 1) Slower then RAID-1, at least in reading (as only single volume being used for reading). 2) Non-reliable on power interrupts, and requires disk cache disabling for prevention of data loss. http://www.joshbryan.com/blog/2008/01/02/lvm2-mirrors-vs-md-raid-1/ Also it seems, at least to several setup guides I read (http://www.tcpdump.com/kb/os/linux/lvm-mirroring/intro.html), that one actually requires a 3rd disk for storing the LVM log. This makes the setup completely unusable on 2 disks installations, and lowers the amount of used mirror disks on higher amount of disks. Can anyone comment the above facts, and let me know his experience of using LVM mirroring? Thanks.

    Read the article

  • Terrible Performance with SATA Drives on Dell PowerEdge, steps to troubleshoot?

    - by Tom
    I had asked this question earlier and the question went missing so here it is again. Bought a DELL Poweredge 2950 to use as in-house QA Server. Disk performance is beyond terrible, 1000-4000 ms response time on the drive with our SQL Server database .mdf. Sql Server disk queue upwards of 300 at times. I'm a software guy, can anyone help me with steps to determine the issue? I don't know what RAID controller it has, how can I determine that? I'm speculating it could be BIOS issue. Perhaps the server used to have another kind of drive in it and when I added SATA the ??? buffer size is wrong??? Perhaps I chose wrong options (chose defaults) when setting up the RAID 1 arrays? I thought RAID 1 was a performance array?

    Read the article

< Previous Page | 26 27 28 29 30 31 32 33 34 35 36 37  | Next Page >