Search Results

Search found 4219 results on 169 pages for 'rich kid smart kid'.

Page 31/169 | < Previous Page | 27 28 29 30 31 32 33 34 35 36 37 38  | Next Page >

  • Strange Recurrent Excessive I/O Wait

    - by Chris
    I know quite well that I/O wait has been discussed multiple times on this site, but all the other topics seem to cover constant I/O latency, while the I/O problem we need to solve on our server occurs at irregular (short) intervals, but is ever-present with massive spikes of up to 20k ms a-wait and service times of 2 seconds. The disk affected is /dev/sdb (Seagate Barracuda, for details see below). A typical iostat -x output would at times look like this, which is an extreme sample but by no means rare: iostat (Oct 6, 2013) tps rd_sec/s wr_sec/s avgrq-sz avgqu-sz await svctm %util 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 16.00 0.00 156.00 9.75 21.89 288.12 36.00 57.60 5.50 0.00 44.00 8.00 48.79 2194.18 181.82 100.00 2.00 0.00 16.00 8.00 46.49 3397.00 500.00 100.00 4.50 0.00 40.00 8.89 43.73 5581.78 222.22 100.00 14.50 0.00 148.00 10.21 13.76 5909.24 68.97 100.00 1.50 0.00 12.00 8.00 8.57 7150.67 666.67 100.00 0.50 0.00 4.00 8.00 6.31 10168.00 2000.00 100.00 2.00 0.00 16.00 8.00 5.27 11001.00 500.00 100.00 0.50 0.00 4.00 8.00 2.96 17080.00 2000.00 100.00 34.00 0.00 1324.00 9.88 1.32 137.84 4.45 59.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 22.00 44.00 204.00 11.27 0.01 0.27 0.27 0.60 Let me provide you with some more information regarding the hardware. It's a Dell 1950 III box with Debian as OS where uname -a reports the following: Linux xx 2.6.32-5-amd64 #1 SMP Fri Feb 15 15:39:52 UTC 2013 x86_64 GNU/Linux The machine is a dedicated server that hosts an online game without any databases or I/O heavy applications running. The core application consumes about 0.8 of the 8 GBytes RAM, and the average CPU load is relatively low. The game itself, however, reacts rather sensitive towards I/O latency and thus our players experience massive ingame lag, which we would like to address as soon as possible. iostat: avg-cpu: %user %nice %system %iowait %steal %idle 1.77 0.01 1.05 1.59 0.00 95.58 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sdb 13.16 25.42 135.12 504701011 2682640656 sda 1.52 0.74 20.63 14644533 409684488 Uptime is: 19:26:26 up 229 days, 17:26, 4 users, load average: 0.36, 0.37, 0.32 Harddisk controller: 01:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 1078 (rev 04) Harddisks: Array 1, RAID-1, 2x Seagate Cheetah 15K.5 73 GB SAS Array 2, RAID-1, 2x Seagate ST3500620SS Barracuda ES.2 500GB 16MB 7200RPM SAS Partition information from df: Filesystem 1K-blocks Used Available Use% Mounted on /dev/sdb1 480191156 30715200 425083668 7% /home /dev/sda2 7692908 437436 6864692 6% / /dev/sda5 15377820 1398916 13197748 10% /usr /dev/sda6 39159724 19158340 18012140 52% /var Some more data samples generated with iostat -dx sdb 1 (Oct 11, 2013) Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sdb 0.00 15.00 0.00 70.00 0.00 656.00 9.37 4.50 1.83 4.80 33.60 sdb 0.00 0.00 0.00 2.00 0.00 16.00 8.00 12.00 836.00 500.00 100.00 sdb 0.00 0.00 0.00 3.00 0.00 32.00 10.67 9.96 1990.67 333.33 100.00 sdb 0.00 0.00 0.00 4.00 0.00 40.00 10.00 6.96 3075.00 250.00 100.00 sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.00 0.00 0.00 100.00 sdb 0.00 0.00 0.00 2.00 0.00 16.00 8.00 2.62 4648.00 500.00 100.00 sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.00 0.00 0.00 100.00 sdb 0.00 0.00 0.00 1.00 0.00 16.00 16.00 1.69 7024.00 1000.00 100.00 sdb 0.00 74.00 0.00 124.00 0.00 1584.00 12.77 1.09 67.94 6.94 86.00 Characteristic charts generated with rrdtool can be found here: iostat plot 1, 24 min interval: http://imageshack.us/photo/my-images/600/yqm3.png/ iostat plot 2, 120 min interval: http://imageshack.us/photo/my-images/407/griw.png/ As we have a rather large cache of 5.5 GBytes, we thought it might be a good idea to test if the I/O wait spikes would perhaps be caused by cache miss events. Therefore, we did a sync and then this to flush the cache and buffers: echo 3 > /proc/sys/vm/drop_caches and directly afterwards the I/O wait and service times virtually went through the roof, and everything on the machine felt like slow motion. During the next few hours the latency recovered and everything was as before - small to medium lags in short, unpredictable intervals. Now my question is: does anybody have any idea what might cause this annoying behaviour? Is it the first indication of the disk array or the raid controller dying, or something that can be easily mended by rebooting? (At the moment we're very reluctant to do this, however, because we're afraid that the disks might not come back up again.) Any help is greatly appreciated. Thanks in advance, Chris. Edited to add: we do see one or two processes go to 'D' state in top, one of which seems to be kjournald rather frequently. If I'm not mistaken, however, this does not indicate the processes causing the latency, but rather those affected by it - correct me if I'm wrong. Does the information about uninterruptibly sleeping processes help us in any way to address the problem? @Andy Shinn requested smartctl data, here it is: smartctl -a -d megaraid,2 /dev/sdb yields: smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: SEAGATE ST3500620SS Version: MS05 Serial number: Device type: disk Transport protocol: SAS Local Time is: Mon Oct 14 20:37:13 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 20 C Drive Trip Temperature: 68 C Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 1236631092 Blocks received from initiator = 1097862364 Blocks read from cache and sent to initiator = 1383620256 Number of read and write commands whose size <= segment size = 531295338 Number of read and write commands whose size > segment size = 51986460 Vendor (Seagate/Hitachi) factory information number of hours powered up = 36556.93 number of minutes until next internal SMART test = 32 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 509271032 47 0 509271079 509271079 20981.423 0 write: 0 0 0 0 0 5022.039 0 verify: 1870931090 196 0 1870931286 1870931286 100558.708 0 Non-medium error count: 0 SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 16 36538 - [- - -] # 2 Background short Completed 16 36514 - [- - -] # 3 Background short Completed 16 36490 - [- - -] # 4 Background short Completed 16 36466 - [- - -] # 5 Background short Completed 16 36442 - [- - -] # 6 Background long Completed 16 36420 - [- - -] # 7 Background short Completed 16 36394 - [- - -] # 8 Background short Completed 16 36370 - [- - -] # 9 Background long Completed 16 36364 - [- - -] #10 Background short Completed 16 36361 - [- - -] #11 Background long Completed 16 2 - [- - -] #12 Background short Completed 16 0 - [- - -] Long (extended) Self Test duration: 6798 seconds [113.3 minutes] smartctl -a -d megaraid,3 /dev/sdb yields: smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: SEAGATE ST3500620SS Version: MS05 Serial number: Device type: disk Transport protocol: SAS Local Time is: Mon Oct 14 20:37:26 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 19 C Drive Trip Temperature: 68 C Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 288745640 Blocks received from initiator = 1097848399 Blocks read from cache and sent to initiator = 1304149705 Number of read and write commands whose size <= segment size = 527414694 Number of read and write commands whose size > segment size = 51986460 Vendor (Seagate/Hitachi) factory information number of hours powered up = 36596.83 number of minutes until next internal SMART test = 28 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 610862490 44 0 610862534 610862534 20470.133 0 write: 0 0 0 0 0 5022.480 0 verify: 2861227413 203 0 2861227616 2861227616 100872.443 0 Non-medium error count: 1 SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 16 36580 - [- - -] # 2 Background short Completed 16 36556 - [- - -] # 3 Background short Completed 16 36532 - [- - -] # 4 Background short Completed 16 36508 - [- - -] # 5 Background short Completed 16 36484 - [- - -] # 6 Background long Completed 16 36462 - [- - -] # 7 Background short Completed 16 36436 - [- - -] # 8 Background short Completed 16 36412 - [- - -] # 9 Background long Completed 16 36404 - [- - -] #10 Background short Completed 16 36401 - [- - -] #11 Background long Completed 16 2 - [- - -] #12 Background short Completed 16 0 - [- - -] Long (extended) Self Test duration: 6798 seconds [113.3 minutes]

    Read the article

  • iPhone Gameloop render update from a separate thread

    - by Rich
    Hi, I'm new to iPhone development. I have a game loop setup as follows. (void)CreateGameTick:(NSTimeInterval) in_time { [NSThread detachNewThreadSelector:@selector(GameTick) toTarget:self withObject:nil]; } My basic game tick/render looks like this (void)GameTick { NSAutoreleasePool *pool = [[NSAutoreleasePool alloc] init]; CGRect wrect = [self bounds]; while( m_running ) { [self drawRect: wrect]; } [pool release]; } My render function gets called. However nothing gets drawn (I am using Core Graphics to draw some lines on a derived UIView). If I call my update via a timer then all is well and good. Can you tell me why the render fails when done via threads? And is it possible to make it work via threads? Thanks Rich

    Read the article

  • ClickOnce deployment to production

    - by gilbertc
    Our smart-client application is deployed using the ClickOnce. Our production site is hosted on 2 separate web servers, and they are pointed from the same domain-name (for load-balancing). Here is what we do when we push updates to the production. In VS, publish the smart-client application into a localhost directory Copy/Paste the directory to the webservers The deployment address from VS is localhost while it is being used in some other production website. Is that a proper way to deploy smart-client applications?

    Read the article

  • OAuth iPhone client, problems with HTTP_AUTHORIZATION

    - by Rich
    Hi, I've been trying to implement OAuth in my iPhone app. However I have hit a problem. I have two servers, a local web server which is on my machine at home, I use this for testing. The machine is IIS 7 running PHP 5.08. Everything works fine on this server. However my live (web server) is running Apache and PHP 5.12. The problem is when I try to request a RequestToken the HTTP_AUTHORIZATION variable isn't posted to the web server, so I get an error returned from the server saying 'Invaild Consumer Key'. There is clearly a problem with the way the server is setup (as the code works on my local server). The code I am using is from this walkthrough http://code.google.com/p/oauthconsumer/wiki/UsingOAuthConsumer I have tried dumping the PHP headers and indeed HTTP_AUTHORIZATION is missing. Can anyone tell me how to fix this? (as it's driving me mad :)) Thanks Rich

    Read the article

  • Why do ticket websites crash?

    - by Soloman Smart
    I hope this fits into the expanse of serverfault. Apologies if it doesn't. Why do ticket websites selling tickets for major concerts/events still crash when they make the tickets available? Surely, they know there is going to be huge demand and can ensure they have capacity to deal with that? May seem like a very simple question so sorry for those who understand! Thanks!

    Read the article

  • Django-ckeditor inline error

    - by ad3w
    I'm using FeinCMS (https://github.com/feincms/feincms/) and django-ckeditor with file upload support (https://github.com/shaunsephton/django-ckeditor). I create a FeinCMS content type for RichTextField: class RichContent(models.Model): text = RichTextField(_('text')) class Meta: abstract = True verbose_name = _('Rich Text') verbose_name_plural =_('Rich Text') def render(self, **kwargs): context_instance = kwargs.get('context_instance') return render_to_string('content/page/rich_content.html', { 'page': self, }, context_instance=context_instance) But in Django admin, when i select 'Rich Text' and press 'Go', get this error in firebug console: uncaught exception: [CKEDITOR.editor] The instance "id_richcontent_set-__prefix__-text" already exists. And textarea in ckeditor do not editable.

    Read the article

  • GDI fast scroll

    - by genesys
    Hi! I use GDI to create some custom textwidget. I draw directly to the screen, unbuffered. now i'd like to implement some fast scrolling, that simply pixelshifts the respective part of the framebuffer (and only redraws the newly visible lines). I noticed that for example the rich text controls does it like this. If i use some GDI drawing functions to directly draw to the framebuffer, over a rich text control, and then scroll the rich text, it will also scroll my drawing along with the text. so i assume the rich text simply pixelshifts it's part of the framebuffer. I'd like to do the same, but don't know how to do so. Can someone help? (independant of programming language)) thanks!

    Read the article

  • Join one row to multiple rows in another table

    - by Ghostrider
    I have a table to entities (lets call them people) and properties (one person can have an arbitrary number of properties). Ex: People Name Age -------- Jane 27 Joe 36 Jim 16 Properties Name Property ----------------- Jane Smart Jane Funny Jane Good-looking Joe Smart Joe Workaholic Jim Funny Jim Young I would like to write an efficient select that would select people based on age and return all or some of their properties. Ex: People older than 26 Name Properties Jane Smart, Funny, Good-looking Joe Smart, Workaholic It's also acceptable to return one of the properties and total property count. The query should be efficient: there are millions of rows in people table, hundreds of thousands of rows in properties table (so most people have no properties). There are hundreds of rows selected at a time. Is there any way to do it?

    Read the article

  • Which quotes does a programmer need?

    - by Masi
    My keyboard only has normal quotes, not the smart ones. I have obversed that I need normal ones in cgi development and the backward ones in AWK/SED. Is there any rule when I should use smart quotes, normal ones and backward ones? Obviously, I need to edit my keyboard layout to get the smart quotes.

    Read the article

  • How to setup directories in Visual Studio when using boost?

    - by Rich
    Hi, I have introduced boost to our code base, on my machine I created a boost directory called Thirdparty.Boost and added that as an additional include directory in my Visual Studio setting, all is fine. However I now want to check in my changes, so the rest of the team can get them. Inorder to build the code they would need to setup boost as I have (problem number 1). In addition we have a build server, which will need changing (problem 2). I have a way of distributing boost to everyone including the build server, so that's not a problem I need a way of referring to the boost directory without changing the default settings in Visual Studio. Why don't you change it on a project level I hear you cry? The solution has over 200 projects, which would require a lot of changes. I just wondered if there was another way? Cheers Rich

    Read the article

  • RichFaces a4j:support parameter passing

    - by Mark Lewis
    Hello I have a number of rich:inplaceInput tags in RichFaces which represent numbers in an array. The validator allows integers only. When a user clicks in an input and changes a value, how can I get the bean to sort the array given the new number and reRender the list of rich:inplaceInput tags so that they're in numerical order? EG <a4j:region> <rich:dataTable value="#{MyBacking.config}" var="feed" cellpadding="0" cellspacing="0" width="100%" border="0" columns="5" id="Admin"> ... <a4j:repeat... <a4j:region id="MsgCon"> <rich:inplaceInput value="#{h.id}" validator="#{MyBacking.validateID}" id="andID" showControls="true"> <a4j:support event="onviewactivated" action="#{MyBacking.sort}" reRender="Admin" /> </rich:inplaceInput> </a4j:region> </a4j:repeat> </data:Table> </a4j:region> Note I do NOT want to use dataTable sort functions. The table is complicated and I've specified id="Admin" (ie the whole table) to reRender as I've not found a way to send more localised values to the backing bean through the inplaceInput. This question is about how to use a4j:support action attribute to call the sort method so that when the reRender rerenders the component, it outputs the list in sorted order. I have the sort method working ok when I click a button to sort, but I want to have the list sorted automatically as soon as a new valid value is entered into the inplaceInput component. Thanks

    Read the article

  • Customising Symfony Admin Generator Form

    - by Rich
    Hi, I've generated the backend of my application, and am now just 'jazzing' the forms up (adding correct labels, validation rules etc). One thing I'd like to do is add a map (Google) which updates the marker as an address is entered into the form, then allows the user to drag it to correct the lat/lng should it be a little off. My question is, how can I customise the output of the form - I've read the docs (1.0,1.1,1.2 also) and it all seems very confusing. Customising forms not generated with the admin generator I know how to do using renderRow(); etc; but finding a way to add a little bit of HTML to the forms is making my eyes hurt! There's so much out of date stuff on the web regarding Symfony it's hard to know what to trust! If anyone can point me in the right direction that'd be great. Best Regards, Rich

    Read the article

  • ui:include disables menu

    - by Goran B
    <rich:tab id="profileInfoTab" label="Information" labelWidth="80"> <ui:include src="/panels/tab2.jsp" /> </rich:tab> <rich:tab id="profileReferenceTab" label="Referenser" labelWidth="80"> <ui:include src="/panels/tab3.jsp" /> </rich:tab> If I include all code in /panel/tab1.jsp instead of the ui:include everything is OK. If I use the ui:include nothing is rendered. Not even the tab-panel. Why? Workarounds?

    Read the article

  • Rendering splash screen on the iPhone using Open GL ES

    - by Rich
    Hi, I want to render a splash screen on the iPhone whilst using an Open GL view. The iPhone screen as we know is 320x480, which is not a power of 2. Before I enter into the world of chopping the texture up and rendering sub parts, or embedding the screen on another texture page I was wondering if there was another way? Is it possible to overlay another view that I could render to using CoreGraphics functions? Or is it possible to render to a Open GL surface using Core Graphics functions. What would you recommend? Cheers Rich

    Read the article

  • Enlist a table's columns in other component

    - by bungrudi
    The main goal is to have a dropdown menu where each of its menuItems represents one column of a <rich:extendedDataTable />. Above the table I have this: <rich:dropDownMenu value="Column visibility" submitMode="none" direction="bottom-right"> <c:forEach var="columnConfigVO" items="#{gridConfigurationManager.getColumnConfigs(listId)}"> <rich:menuItem value="columnConfigVO.columnId" /> </c:forEach> </rich:dropDownMenu> And then bellow that I have the usual <rich:extendedDataTable /> with its columns. I register the table columns to gridConfigurationManager component by overriding beforeRenderResponse() in ExtendedDataTable class. The problem is that <c:forEach /> is executing before renderResponse phase, thus gridConfigurationManager.getColumnConfigs(listId) return empty. The question is, how do I register the columns in gridConfigurationManager component before <c:forEach /> start executing? Or, anyone know a different approach to accomplish this? Thanks.

    Read the article

  • An explanation of memory usage on Windows server 2003

    - by Rich
    Hi, We've been working on a bit of puzzle at work. We have an application service installed on two machines, both running Windows server 2003. These services do exactly the same thing. However once loaded, one of the services uses 200mb less than the other service. We're at a bit of a loss to what might be causing this discrepancy. I was wondering if there was some kind of server setting that would cause an application to use more memory (heap block size) or anything to explain this. If anyone has any ideas on what may be causing this, or how to find out what is causing this I'd be very grateful. Cheers Rich

    Read the article

  • skills that can't be outsourced- web development related

    - by Matt Derami
    I never know where it's acceptable to post something like this, so please forgive if it's in the wrong place. I'm very interested in going further in to web development; I know a bit of javascript, a bit of php, and so forth, but I'm now seeing these services that will go from psd to wordpress for 200 bucks and I'm wondering how the hell is anyone able to compete with this? So I'm wondering if those more knowledgeable than me could tell me what areas are the least likely to be able to be outsourced, for 5 bucks to some kid in Uzbekistan( no offense to that kid).. do you think it's on the database management side, or maybe app development? ideas appreciated.

    Read the article

  • Ubuntu Audio Pitch Shifting filter

    - by user777305
    I'm currently developing a video player software which intended to be an embeedded player. I'm using Java with VLCJ library for the video player. What i'm looking is a way, something to transform the audio output to make the output sound as oldman or a kid (pitch shifting, i guess is the name). VLC have this when enabling time stretch, but the video play speed is affected (slower to get oldman sound, but fast-forward-alike to get kid voice effect. Is there any solutions for this? I don't find this feature on VLC(J), so i think what i need is the audio output of the ubuntu itself (Ubuntu 12.04) to do this job. something like filtering audio output system wide. Any software or setting to do this? it also need to be controllable via command line to provide realtime effect changing. Thanks in advance.

    Read the article

  • Embedding ADF UI Components into OAF regions

    - by Juan Camilo Ruiz
    Having finished the 2 Webcast on ADF integration with Oracle E-Business Suite, Sara Woodhull, Principal Product Manager on the Oracle E-Business Suite Applications Technology team and I are going to continue adding entries to the series on this topic, trying to cover as many use cases as possible. In this entry, Sara created an overview on how Oracle ADF pages can be embedded into an Oracle Application Framework region. This is a very interesting approach that will enable those of you who are exploring ADF as a technology stack to enhanced some of the Oracle E-Business Suite flows and leverage your skill on Oracle Applications Framework (OAF). In upcoming entries we will start unveiling the internals needed to achieve session sharing between the regions. Stay tuned for more entries and enjoy this new post.   Document Scope This document only covers information that is specific to embedding an Oracle ADF page in an Oracle Application Framework–based page. It assumes knowledge of Oracle ADF and Oracle Application Framework development. It also assumes knowledge of the material in My Oracle Support Note 974949.1, “Oracle E-Business Suite SDK for Java” and My Oracle Support Note 1296491.1, "FAQ for Integration of Oracle E-Business Suite and Oracle Application Development Framework (ADF) Applications". Prerequisite Patch Download Patch 12726556:R12.FND.B from My Oracle Support and install it. The implementation described below requires Patch 12726556:R12.FND.B to provide the accessors for the ADF page. This patch is required in addition to the Oracle E-Business Suite SDK for Java patch described in My Oracle Support Note 974949.1. Development Environments You need two different JDeveloper environments: Oracle ADF and OA Framework. Oracle ADF Development Environment You build your Oracle ADF page using JDeveloper 11g. You should use JDeveloper 11g R1 (the latest is 11.1.1.6.0) if you need to use other products in the Oracle Fusion Middleware Stack, such as Oracle WebCenter, Oracle SOA Suite, or BI. You should use JDeveloper 11g R2 (the latest is 11.1.2.3.0) if you do not need other Oracle Fusion Middleware products. JDeveloper 11g R2 is an Oracle ADF-specific release that supports the latest Java EE standards and has various core improvements. Oracle Application Framework Development Environment Build your OA Framework page using a development environment corresponding to your Oracle E-Business Suite version. You must use Release 12.1.2 or later because the rich content container was introduced in Release 12.1.2. See “OA Framework - How to find the correct version of JDeveloper to use with eBusiness Suite 11i or Release 12.x” (My Oracle Support Doc ID 416708.1). Building your Oracle ADF Page Typically you build your ADF page using the session management feature of the Oracle E-Business Suite SDK for Java as described in My Oracle Support Note 974949.1. Also see My Oracle Support Note 1296491.1, "FAQ for Integration of Oracle E-Business Suite and Oracle Application Development Framework (ADF) Applications". Building an ADF Page with the Hierarchy Viewer If you are using the ADF hierarchy viewer, you should set up the structure and settings of the ADF page as follows or the hierarchy viewer may not fill the entire area it is supposed to fill (especially a problem in Firefox). Create a stretchable component as the parent component for the hierarchy viewer, such as af:panelStretchLayout (underneath the af:form component in the structure). Use af:panelStretchLayout for Oracle ADF 11.1.1.6 and earlier. For later versions of Oracle ADF, use af:panelGridLayout. Create your hierarchy viewer component inside the stretchable component. Create Function in Oracle E-Business Suite Instance In your Oracle E-Business Suite instance, create a function for your ADF page with the following parameters. You can use either the Functions window in the System Administrator responsibility or the Functions page in the Functional Administrator responsibility. Function Function Name Type=External ADF Function (ADFX) HTML Call=GWY.jsp?targetPage=faces/<your ADF page> ">You must also add your function to an Oracle E-Business Suite menu or permission set and set up function security or role-based access control (RBAC) so that the user has authorization to access the function. If you do not want the function to appear on the navigation menu, add the function without a menu prompt. See the Oracle E-Business Suite System Administrator's Guide Documentation Set for more information. Testing the Function from the Oracle E-Business Suite Home Page It’s a good idea to test launching your ADF page from the Oracle E-Business Suite Home Page. Add your function to the navigation menu for your responsibility with a prompt and try launching it. If your ADF page expects parameters from the surrounding page, those might not be available, however. Setting up the Oracle Application Framework Rich Container Once you have built your Oracle ADF 11g page, you need to embed it in your Oracle Application Framework page. Create Rich Content Container in your OA Framework JDeveloper environment In the OA Extension Structure pane for your OAF page, select the region where you want to add the rich content, and add a richContainer item to the region. Set the following properties on the richContainer item: id Content Type=Others (for Release 12.1.3. This property value may change in a future release.) Destination Function=[function code] Width (in pixels or percent, such as 100%) Height (in pixels) Parameters=[any parameters your Oracle ADF page is expecting to receive from the Oracle Application Framework page] Parameters In the Parameters property, specify parameters that will be passed to the embedded content as a list of comma-separated, name-value pairs. Dynamic parameters may be specified as paramName={@viewAttr}. Dynamic Rich Content Container Properties If you want your rich content container to display a different Oracle ADF page depending on other information, you would set up a different function for each different Oracle ADF page. You would then set the Destination Function and Parameters properties programmatically, instead of setting them in the Property Inspector. In the processRequest() method of your Oracle Application Framework page controller, where OAFRichContentPage is the ID of your richContainer item and the parameters are whatever parameters your ADF page expects, your code might look similar to this code fragment: OARichContainerBean richBean = (OARichContainerBean) webBean.findChildRecursive("OAFRichContentPage"); if(richBean != null){ if(isFirstCondition){ richBean.setFunctionName("ADF_EXAMPLE_EMBEDDED"); richBean.setParameters("ParamLoginPersonId="+loginPersonId +"&ParamPersonId="+personId+"&ParamUserId="+userId +"&ParamRespId="+respId+"&ParamRespApplId="+respApplId +"&ParamFromOA=Y"+"&ParamSecurityGroupId="+securityGroupId); } else if(isSecondCondition){ richBean.setFunctionName("ADF_EXAMPLE_OTHER_FUNCTION"); richBean.setParameters("ParamLoginPersonId=" +loginPersonId+"&ParamPersonId="+personId +"&ParamUserId="+userId+"&ParamRespId="+respId +"&ParamRespApplId="+respApplId +"&ParamFromOA=Y" +"&ParamSecurityGroupId="+securityGroupId); } }

    Read the article

  • Top YouTube Plugins for WordPress Blogs

    - by Matt
    Smart Youtube Smart Youtube allow you to insert video and playlists into your WordPress post and in your RSS feed. It is perfectly work son Works on iPhone, iPad and iPod etc and issues a sidebar widget for videos as well. WP YouTube WP YouTube act as a a profile editor, where you can set [...] Related posts:WordPress Plugins to Help Make Your Site Responsive 15 Useful SEO Plugins For WordPress The Top 10 WordPress RSS Plugins

    Read the article

  • How to Identify Which Hardware Component is Failing in Your Computer

    - by Chris Hoffman
    Concluding that your computer has a hardware problem is just the first step. If you’re dealing with a hardware issue and not a software issue, the next step is determining what hardware problem you’re actually dealing with. If you purchased a laptop or pre-built desktop PC and it’s still under warranty, you don’t need to care about this. Have the manufacturer fix the PC for you — figuring it out is their problem. If you’ve built your own PC or you want to fix a computer that’s out of warranty, this is something you’ll need to do on your own. Blue Screen 101: Search for the Error Message This may seem like obvious advice, but searching for information about a blue screen’s error message can help immensely. Most blue screens of death you’ll encounter on modern versions of Windows will likely be caused by hardware failures. The blue screen of death often displays information about the driver that crashed or the type of error it encountered. For example, let’s say you encounter a blue screen that identified “NV4_disp.dll” as the driver that caused the blue screen. A quick Google search will reveal that this is the driver for NVIDIA graphics cards, so you now have somewhere to start. It’s possible that your graphics card is failing if you encounter such an error message. Check Hard Drive SMART Status Hard drives have a built in S.M.A.R.T. (Self-Monitoring, Analysis, and Reporting Technology) feature. The idea is that the hard drive monitors itself and will notice if it starts to fail, providing you with some advance notice before the drive fails completely. This isn’t perfect, so your hard drive may fail even if SMART says everything is okay. If you see any sort of “SMART error” message, your hard drive is failing. You can use SMART analysis tools to view the SMART health status information your hard drives are reporting. Test Your RAM RAM failure can result in a variety of problems. If the computer writes data to RAM and the RAM returns different data because it’s malfunctioning, you may see application crashes, blue screens, and file system corruption. To test your memory and see if it’s working properly, use Windows’ built-in Memory Diagnostic tool. The Memory Diagnostic tool will write data to every sector of your RAM and read it back afterwards, ensuring that all your RAM is working properly. Check Heat Levels How hot is is inside your computer? Overheating can rsult in blue screens, crashes, and abrupt shut downs. Your computer may be overheating because you’re in a very hot location, it’s ventilated poorly, a fan has stopped inside your computer, or it’s full of dust. Your computer monitors its own internal temperatures and you can access this information. It’s generally available in your computer’s BIOS, but you can also view it with system information utilities such as SpeedFan or Speccy. Check your computer’s recommended temperature level and ensure it’s within the appropriate range. If your computer is overheating, you may see problems only when you’re doing something demanding, such as playing a game that stresses your CPU and graphics card. Be sure to keep an eye on how hot your computer gets when it performs these demanding tasks, not only when it’s idle. Stress Test Your CPU You can use a utility like Prime95 to stress test your CPU. Such a utility will fore your computer’s CPU to perform calculations without allowing it to rest, working it hard and generating heat. If your CPU is becoming too hot, you’ll start to see errors or system crashes. Overclockers use Prime95 to stress test their overclock settings — if Prime95 experiences errors, they throttle back on their overclocks to ensure the CPU runs cooler and more stable. It’s a good way to check if your CPU is stable under load. Stress Test Your Graphics Card Your graphics card can also be stress tested. For example, if your graphics driver crashes while playing games, the games themselves crash, or you see odd graphical corruption, you can run a graphics benchmark utility like 3DMark. The benchmark will stress your graphics card and, if it’s overheating or failing under load, you’ll see graphical problems, crashes, or blue screens while running the benchmark. If the benchmark seems to work fine but you have issues playing a certain game, it may just be a problem with that game. Swap it Out Not every hardware problem is easy to diagnose. If you have a bad motherboard or power supply, their problems may only manifest through occasional odd issues with other components. It’s hard to tell if these components are causing problems unless you replace them completely. Ultimately, the best way to determine whether a component is faulty is to swap it out. For example, if you think your graphics card may be causing your computer to blue screen, pull the graphics card out of your computer and swap in a new graphics card. If everything is working well, it’s likely that your previous graphics card was bad. This isn’t easy for people who don’t have boxes of components sitting around, but it’s the ideal way to troubleshoot. Troubleshooting is all about trial and error, and swapping components out allows you to pin down which component is actually causing the problem through a process of elimination. This isn’t a complete guide to everything that could likely go wrong and how to identify it — someone could write a full textbook on identifying failing components and still not cover everything. But the tips above should give you some places to start dealing with the more common problems. Image Credit: Justin Marty on Flickr     

    Read the article

  • Is my hard drive about to fail?

    - by Cody Harlow
    I hear some squeaking noises sometimes when I use my computer so I ran smartctl. This is the results: === START OF READ SMART DATA SECTION === SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed: read failure 90% 5953 37922655 # 2 Extended offline Completed: read failure 90% 5953 37922655 # 3 Short offline Completed: read failure 90% 5953 37922655 # 4 Short offline Completed without error 00% 429 - # 5 Extended offline Aborted by host 90% 429 - # 6 Short offline Completed without error 00% 429 - # 7 Short offline Completed without error 00% 429 - Is this a bad sign?

    Read the article

  • XSL Transformations in .NET 2.0

    Having realized the need for efficient built-in support for XSLT processing, Microsoft has included in the .NET Framework 2.0 a set of classes that are highly optimized, robust, and scalable. This article will explore the rich XSLT support provided by the .NET Framework 2.0 by providing examples on how to use the XSLT related classes to create rich ASP.NET Web applications.

    Read the article

  • The Power of AJAX and How to Use it

    Since its conception in 2005, AJAX (Asynchronous Javascript and XML) has changed the web world as we know it today. It's helped websites evolve into RIAs (rich internet applications) by allowing webpages to make direct requests to a web server without reloading the page. This capability is vital in replicating the rich user experiences achieved in client applications. The purpose of this post is to help newcomers understand the different ways that AJAX can be used to create RIAs.

    Read the article

< Previous Page | 27 28 29 30 31 32 33 34 35 36 37 38  | Next Page >