Search Results

Search found 44956 results on 1799 pages for 'type checking'.

Page 318/1799 | < Previous Page | 314 315 316 317 318 319 320 321 322 323 324 325  | Next Page >

  • Tunnel is up but cannot ping directly connected network

    - by drmanalo
    We configured a site-to-site VPN and here is the topology. I control the network on the left but not the one on the right. All devices in our network has public IPs. Server---ASA5505---Cisco887======Internet=====ASA5510---devices I can see the tunnel is up and can do extended ping using a loopback interface. From the 10.175 and 10.165 networks, they can also ping my loopback address. I can also dial in using a Cisco VPN client, and can connect to the devices on the right. #show crypto session Crypto session current status Interface: Vlan3 Profile: xxx-profile Session status: UP-ACTIVE Peer: 213.121.x.x port 500 IKEv1 SA: local 77.245.x.x/500 remote 213.121.x.x/500 Active IPSEC FLOW: permit ip 10.0.20.0/255.255.255.240 10.175.0.0/255.255.128.0 Active SAs: 0, origin: crypto map IPSEC FLOW: permit ip 10.0.20.0/255.255.255.240 10.165.0.0/255.255.192.0 Active SAs: 2, origin: crypto map #ping 10.165.29.39 source loopback 2 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 10.165.29.39, timeout is 2 seconds: Packet sent with a source address of 10.0.20.1 !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 16/17/20 ms My problem is the devices on the right cannot reach my server. They could only ping the loopback address and nothing else. I'm pasting some diagnostics related to routing thinking perhaps routing is my issue. I can paste all the running-config on my side of network if needed. #show ip int brief Interface IP-Address OK? Method Status Protocol ATM0 unassigned YES NVRAM administratively down down Ethernet0 unassigned YES NVRAM administratively down down FastEthernet0 unassigned YES unset up up connected to ASA FastEthernet1 unassigned YES unset administratively down down FastEthernet2 unassigned YES unset administratively down down FastEthernet3 unassigned YES unset up up Loopback1 10.0.20.65 YES NVRAM up up Loopback2 10.0.20.1 YES NVRAM up up Virtual-Template1 77.245.x.x YES unset up down Virtual-Template2 77.245.x.x YES unset up down Vlan1 unassigned YES unset down down Vlan3 77.245.x.x YES NVRAM up up connected to the Internet #show run | section ip route ip route 0.0.0.0 0.0.0.0 77.245.x.x ip route 213.121.240.36 255.255.255.255 Vlan3 #show access-list Extended IP access list 102 10 permit ip 10.0.20.0 0.0.0.15 10.175.0.0 0.0.127.255 (3332 matches) 20 permit ip 10.0.20.0 0.0.0.15 10.165.0.0 0.0.63.255 (3498 matches) #show vlan-switch VLAN Name Status Ports ---- -------------------------------- --------- ------------------------------- 1 default active 3 VLAN0003 active Fa0, Fa1, Fa2, Fa3 1002 fddi-default act/unsup 1003 token-ring-default act/unsup 1004 fddinet-default act/unsup 1005 trnet-default act/unsup #show ip route Codes: L - local, C - connected, S - static, R - RIP, M - mobile, B - BGP D - EIGRP, EX - EIGRP external, O - OSPF, IA - OSPF inter area N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2 E1 - OSPF external type 1, E2 - OSPF external type 2 i - IS-IS, su - IS-IS summary, L1 - IS-IS level-1, L2 - IS-IS level-2 ia - IS-IS inter area, * - candidate default, U - per-user static route o - ODR, P - periodic downloaded static route, H - NHRP, l - LISP + - replicated route, % - next hop override Gateway of last resort is 77.245.x.x to network 0.0.0.0 S* 0.0.0.0/0 [1/0] via 77.245.x.x 10.0.0.0/8 is variably subnetted, 5 subnets, 3 masks C 10.0.20.0/28 is directly connected, Loopback2 L 10.0.20.1/32 is directly connected, Loopback2 C 10.0.20.64/28 is directly connected, Loopback1 L 10.0.20.65/32 is directly connected, Loopback1 S 10.165.0.0/18 [1/0] via 213.121.x.x 77.0.0.0/8 is variably subnetted, 3 subnets, 3 masks S 77.0.0.0/8 [1/0] via 77.245.x.x C 77.245.x.x/29 is directly connected, Vlan3 L 77.245.x.x/32 is directly connected, Vlan3 213.121.x.0/32 is subnetted, 1 subnets S 213.121.x.x is directly connected, Vlan3 I read some of the posts here which lead to NATing issue but I'not sure of my next step. Should I translate my public address to private and route it to the loopback address? (only guessing) CISCO VPN site to site Site-to-Site VPN between two ASA 5505s only working in one direction Hope someone could help. Thanks in advance!

    Read the article

  • C# 4.0: COM Interop Improvements

    - by Paulo Morgado
    Dynamic resolution as well as named and optional arguments greatly improve the experience of interoperating with COM APIs such as Office Automation Primary Interop Assemblies (PIAs). But, in order to alleviate even more COM Interop development, a few COM-specific features were also added to C# 4.0. Ommiting ref Because of a different programming model, many COM APIs contain a lot of reference parameters. These parameters are typically not meant to mutate a passed-in argument, but are simply another way of passing value parameters. Specifically for COM methods, the compiler allows to declare the method call passing the arguments by value and will automatically generate the necessary temporary variables to hold the values in order to pass them by reference and will discard their values after the call returns. From the point of view of the programmer, the arguments are being passed by value. This method call: object fileName = "Test.docx"; object missing = Missing.Value; document.SaveAs(ref fileName, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing, ref missing); can now be written like this: document.SaveAs("Test.docx", Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value, Missing.Value); And because all parameters that are receiving the Missing.Value value have that value as its default value, the declaration of the method call can even be reduced to this: document.SaveAs("Test.docx"); Dynamic Import Many COM methods accept and return variant types, which are represented in the PIAs as object. In the vast majority of cases, a programmer calling these methods already knows the static type of a returned object form the context of the call, but has to explicitly perform a cast on the returned values to make use of that knowledge. These casts are so common that they constitute a major nuisance. To make the developer’s life easier, it is now possible to import the COM APIs in such a way that variants are instead represented using the type dynamic which means that COM signatures have now occurrences of dynamic instead of object. This means that members of a returned object can now be easily accessed or assigned into a strongly typed variable without having to cast. Instead of this code: ((Excel.Range)(excel.Cells[1, 1])).Value2 = "Hello World!"; this code can now be used: excel.Cells[1, 1] = "Hello World!"; And instead of this: Excel.Range range = (Excel.Range)(excel.Cells[1, 1]); this can be used: Excel.Range range = excel.Cells[1, 1]; Indexed And Default Properties A few COM interface features are still not available in C#. On the top of the list are indexed properties and default properties. As mentioned above, these will be possible if the COM interface is accessed dynamically, but will not be recognized by statically typed C# code. No PIAs – Type Equivalence And Type Embedding For assemblies indentified with PrimaryInteropAssemblyAttribute, the compiler will create equivalent types (interfaces, structs, enumerations and delegates) and embed them in the generated assembly. To reduce the final size of the generated assembly, only the used types and their used members will be generated and embedded. Although this makes development and deployment of applications using the COM components easier because there’s no need to deploy the PIAs, COM component developers are still required to build the PIAs.

    Read the article

  • eth0 and eth1 both assigned same IP on boot

    - by Banjer
    I have a physical SLES 11 SP2 server on a Sun Fire x4140 that is giving me problems with networking upon reboot. The NICs are onboard. The networking appears successful during boot, but network services such as nfs fail hard. This is because eth0 and eth1 are both receiving the same configuration and are both ifup-ed. Once everything times out and I'm at the console, ifconfig shows that eth0 and eth1 are UP and running with the same IP. Attempting to ping anything in that subnet fails. Restarting the network service fixes the issue. eth0 is the correct NIC that should be configured as primary, per the MAC address. Question: Whats causing eth1 to be brought up with the same config as eth0?? I do not have a config script set up for eth1: banjer@harp:~> ls -la /etc/sysconfig/network/ total 104 drwxr-xr-x 6 root root 4096 Jun 11 12:21 . drwxr-xr-x 6 root root 4096 Apr 10 09:46 .. -rw-r--r-- 1 root root 13916 Apr 10 09:32 config -rw-r--r-- 1 root root 9952 Apr 10 09:36 dhcp -rw------- 1 root root 180 Jun 11 12:21 ifcfg-eth0 -rw------- 1 root root 180 Jun 11 12:21 ifcfg-eth3 -rw------- 1 root root 172 Feb 1 08:32 ifcfg-lo -rw-r--r-- 1 root root 29333 Feb 1 08:32 ifcfg.template drwxr-xr-x 2 root root 4096 Apr 10 09:32 if-down.d -rw-r--r-- 1 root root 239 Feb 1 08:32 ifroute-lo drwxr-xr-x 2 root root 4096 Apr 10 09:33 if-up.d drwx------ 2 root root 4096 May 5 2010 providers -rw-r--r-- 1 root root 25 Nov 16 2010 routes drwxr-xr-x 2 root root 4096 Apr 10 09:36 scripts On a side note, eth3 is also configured with an IP in a different subnet, but this has not posed any problems. FYI the kernel module being used is forcedeth. banjer@harp:~> sudo cat /etc/sysconfig/network/ifcfg-eth0 BOOTPROTO='static' BROADCAST='' ETHTOOL_OPTIONS='' IPADDR='172.21.64.25/20' MTU='' NAME='MCP55 Ethernet' NETWORK='' REMOTE_IPADDR='' STARTMODE='auto' USERCONTROL='no' ONBOOT="yes" Here's eth3 in case you need to see it: banjer@harp:~> sudo cat /etc/sysconfig/network/ifcfg-eth3 BOOTPROTO='static' BROADCAST='' ETHTOOL_OPTIONS='' IPADDR='172.11.200.4/24' MTU='' NAME='MCP55 Ethernet' NETWORK='' REMOTE_IPADDR='' STARTMODE='auto' USERCONTROL='no' ONBOOT="yes" Perhaps is something related to udev? 70-persistent-net-rules looks OK to me, but I may not understand it completely. banjer@harp:~> cat /etc/udev/rules.d/70-persistent-net.rules # This file was automatically generated by the /lib/udev/write_net_rules # program, run by the persistent-net-generator.rules rules file. # # You can modify it, as long as you keep each rule on a single # line, and change only the value of the NAME= key. # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4c", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth2" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4a", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth0" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4b", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth1" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4d", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth3" # PCI device 0x1077:0x3032 (qla3xxx) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:c1:dd:0e:34:6c", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth4" Any other thoughts on what would cause this?

    Read the article

  • Banshee encountered a Fatal Error (sqlite error 11: database disk image is malformed)

    - by Nik
    I am running ubuntu 10.10 Maverick Meerkat, and recently I am helping in testing out indicator-weather using the unstable buids. However there was a bug which caused my system to freeze suddenly (due to indicator-weather not ubuntu) and the only way to recover is to do a hard reset of the system. This happened a couple of times. And when i tried to open banshee after a couple of such resets I get the following fatal error which forces me to quit banshee. The screenshot is not clear enough to read the error, so I am posting it below, An unhandled exception was thrown: Sqlite error 11: database disk image is malformed (SQL: BEGIN TRANSACTION; DELETE FROM CoreSmartPlaylistEntries WHERE SmartPlaylistID IN (SELECT SmartPlaylistID FROM CoreSmartPlaylists WHERE IsTemporary = 1); DELETE FROM CoreSmartPlaylists WHERE IsTemporary = 1; COMMIT TRANSACTION) at Hyena.Data.Sqlite.Connection.CheckError (Int32 errorCode, System.String sql) [0x00000] in <filename unknown>:0 at Hyena.Data.Sqlite.Connection.Execute (System.String sql) [0x00000] in <filename unknown>:0 at Hyena.Data.Sqlite.HyenaSqliteCommand.Execute (Hyena.Data.Sqlite.HyenaSqliteConnection hconnection, Hyena.Data.Sqlite.Connection connection) [0x00000] in <filename unknown>:0 Exception has been thrown by the target of an invocation. at System.Reflection.MonoCMethod.Invoke (System.Object obj, BindingFlags invokeAttr, System.Reflection.Binder binder, System.Object[] parameters, System.Globalization.CultureInfo culture) [0x00000] in <filename unknown>:0 at System.Reflection.MonoCMethod.Invoke (BindingFlags invokeAttr, System.Reflection.Binder binder, System.Object[] parameters, System.Globalization.CultureInfo culture) [0x00000] in <filename unknown>:0 at System.Reflection.ConstructorInfo.Invoke (System.Object[] parameters) [0x00000] in <filename unknown>:0 at System.Activator.CreateInstance (System.Type type, Boolean nonPublic) [0x00000] in <filename unknown>:0 at System.Activator.CreateInstance (System.Type type) [0x00000] in <filename unknown>:0 at Banshee.Gui.GtkBaseClient.Startup () [0x00000] in <filename unknown>:0 at Hyena.Gui.CleanRoomStartup.Startup (Hyena.Gui.StartupInvocationHandler startup) [0x00000] in <filename unknown>:0 .NET Version: 2.0.50727.1433 OS Version: Unix 2.6.35.27 Assembly Version Information: gkeyfile-sharp (1.0.0.0) Banshee.AudioCd (1.9.0.0) Banshee.MiniMode (1.9.0.0) Banshee.CoverArt (1.9.0.0) indicate-sharp (0.4.1.0) notify-sharp (0.4.0.0) Banshee.SoundMenu (1.9.0.0) Banshee.Mpris (1.9.0.0) Migo (1.9.0.0) Banshee.Podcasting (1.9.0.0) Banshee.Dap (1.9.0.0) Banshee.LibraryWatcher (1.9.0.0) Banshee.MultimediaKeys (1.9.0.0) Banshee.Bpm (1.9.0.0) Banshee.YouTube (1.9.0.0) Banshee.WebBrowser (1.9.0.0) Banshee.Wikipedia (1.9.0.0) pango-sharp (2.12.0.0) Banshee.Fixup (1.9.0.0) Banshee.Widgets (1.9.0.0) gio-sharp (2.14.0.0) gudev-sharp (1.0.0.0) Banshee.Gio (1.9.0.0) Banshee.GStreamer (1.9.0.0) System.Configuration (2.0.0.0) NDesk.DBus.GLib (1.0.0.0) gconf-sharp (2.24.0.0) Banshee.Gnome (1.9.0.0) Banshee.NowPlaying (1.9.0.0) Mono.Cairo (2.0.0.0) System.Xml (2.0.0.0) Banshee.Core (1.9.0.0) Hyena.Data.Sqlite (1.9.0.0) System.Core (3.5.0.0) gdk-sharp (2.12.0.0) Mono.Addins (0.4.0.0) atk-sharp (2.12.0.0) Hyena.Gui (1.9.0.0) gtk-sharp (2.12.0.0) Banshee.ThickClient (1.9.0.0) Nereid (1.9.0.0) NDesk.DBus.Proxies (0.0.0.0) Mono.Posix (2.0.0.0) NDesk.DBus (1.0.0.0) glib-sharp (2.12.0.0) Hyena (1.9.0.0) System (2.0.0.0) Banshee.Services (1.9.0.0) Banshee (1.9.0.0) mscorlib (2.0.0.0) Platform Information: Linux 2.6.35-27-generic i686 unknown GNU/Linux Disribution Information: [/etc/lsb-release] DISTRIB_ID=Ubuntu DISTRIB_RELEASE=10.10 DISTRIB_CODENAME=maverick DISTRIB_DESCRIPTION="Ubuntu 10.10" [/etc/debian_version] squeeze/sid Just to make it clear, this happened only after the hard resets and not before. I used to use banshee everyday and it worked perfectly. Can anyone help me fix this?

    Read the article

  • Enhanced Dynamic Filtering

    - by Ricardo Peres
    Remember my last post on dynamic filtering? Well, this time I'm extending the code in order to allow two levels of querying: Match type, represented by the following options: public enum MatchType { StartsWith = 0, Contains = 1 } And word match: public enum WordMatch { AnyWord = 0, AllWords = 1, ExactPhrase = 2 } You can combine the two levels in order to achieve the following combinations: MatchType.StartsWith + WordMatch.AnyWord Matches any record that starts with any of the words specified MatchType.StartsWith + WordMatch.AllWords Not available: does not make sense, throws an exception MatchType.StartsWith + WordMatch.ExactPhrase Matches any record that starts with the exact specified phrase MatchType.Contains + WordMatch.AnyWord Matches any record that contains any of the specified words MatchType.Contains + WordMatch.AllWords Matches any record that contains all of the specified words MatchType.Contains + WordMatch.ExactPhrase Matches any record that contains the exact specified phrase Here is the code: public static IList Search(IQueryable query, Type entityType, String dataTextField, String phrase, MatchType matchType, WordMatch wordMatch, Int32 maxCount) { String [] terms = phrase.Split(' ').Distinct().ToArray(); StringBuilder result = new StringBuilder(); PropertyInfo displayProperty = entityType.GetProperty(dataTextField); IList searchList = null; MethodInfo orderByMethod = typeof(Queryable).GetMethods(BindingFlags.Public | BindingFlags.Static).Where(m = m.Name == "OrderBy").ToArray() [ 0 ].MakeGenericMethod(entityType, displayProperty.PropertyType); MethodInfo takeMethod = typeof(Queryable).GetMethod("Take", BindingFlags.Public | BindingFlags.Static).MakeGenericMethod(entityType); MethodInfo whereMethod = typeof(Queryable).GetMethods(BindingFlags.Public | BindingFlags.Static).Where(m = m.Name == "Where").ToArray() [ 0 ].MakeGenericMethod(entityType); MethodInfo distinctMethod = typeof(Queryable).GetMethods(BindingFlags.Public | BindingFlags.Static).Where(m = m.Name == "Distinct" && m.GetParameters().Length == 1).Single().MakeGenericMethod(entityType); MethodInfo toListMethod = typeof(Enumerable).GetMethod("ToList", BindingFlags.Static | BindingFlags.Public).MakeGenericMethod(entityType); MethodInfo matchMethod = typeof(String).GetMethod ( (matchType == MatchType.StartsWith) ? "StartsWith" : "Contains", new Type [] { typeof(String) } ); MemberExpression member = Expression.MakeMemberAccess ( Expression.Parameter(entityType, "n"), displayProperty ); MethodCallExpression call = null; LambdaExpression where = null; LambdaExpression orderBy = Expression.Lambda ( member, member.Expression as ParameterExpression ); switch (matchType) { case MatchType.StartsWith: switch (wordMatch) { case WordMatch.AnyWord: call = Expression.Call ( member, matchMethod, Expression.Constant(terms [ 0 ]) ); where = Expression.Lambda ( call, member.Expression as ParameterExpression ); for (Int32 i = 1; i ()); where = Expression.Lambda ( Expression.Or ( where.Body, exp ), where.Parameters.ToArray() ); } break; case WordMatch.ExactPhrase: call = Expression.Call ( member, matchMethod, Expression.Constant(phrase) ); where = Expression.Lambda ( call, member.Expression as ParameterExpression ); break; case WordMatch.AllWords: throw (new Exception("The match type StartsWith is not supported with word match AllWords")); } break; case MatchType.Contains: switch (wordMatch) { case WordMatch.AnyWord: call = Expression.Call ( member, matchMethod, Expression.Constant(terms [ 0 ]) ); where = Expression.Lambda ( call, member.Expression as ParameterExpression ); for (Int32 i = 1; i ()); where = Expression.Lambda ( Expression.Or ( where.Body, exp ), where.Parameters.ToArray() ); } break; case WordMatch.ExactPhrase: call = Expression.Call ( member, matchMethod, Expression.Constant(phrase) ); where = Expression.Lambda ( call, member.Expression as ParameterExpression ); break; case WordMatch.AllWords: call = Expression.Call ( member, matchMethod, Expression.Constant(terms [ 0 ]) ); where = Expression.Lambda ( call, member.Expression as ParameterExpression ); for (Int32 i = 1; i ()); where = Expression.Lambda ( Expression.AndAlso ( where.Body, exp ), where.Parameters.ToArray() ); } break; } break; } query = orderByMethod.Invoke(null, new Object [] { query, orderBy }) as IQueryable; query = whereMethod.Invoke(null, new Object [] { query, where }) as IQueryable; if (maxCount != 0) { query = takeMethod.Invoke(null, new Object [] { query, maxCount }) as IQueryable; } searchList = toListMethod.Invoke(null, new Object [] { query }) as IList; return (searchList); } And this is how you'd use it: IQueryable query = ctx.MyEntities; IList list = Search(query, typeof(MyEntity), "Name", "Ricardo Peres", MatchType.Contains, WordMatch.ExactPhrase, 10 /*0 for all*/); SyntaxHighlighter.config.clipboardSwf = 'http://alexgorbatchev.com/pub/sh/2.0.320/scripts/clipboard.swf'; SyntaxHighlighter.brushes.CSharp.aliases = ['c#', 'c-sharp', 'csharp']; SyntaxHighlighter.all();

    Read the article

  • Web.config WordPress rewrite rules next to Magento

    - by Flo
    I've installed Magento on IIS in folder: E:\mydomain\wwwroot (I already have it all running correctly). I have no deeper folder magento, I placed all files directly in the wwwroot folder, so: wwwroot\app wwwroot\downloader wwwroot\errors wwwroot\includes etc... UPDATE: since I'm on IIS my .htaccess is ignored completely and my web.config rules are used instead. Here's my web.config in folder e:\mydomain\wwwroot: <?xml version="1.0" encoding="UTF-8"?> <configuration> <system.webServer> <rewrite> <rules> <rule name="Magento SEO: remove index.php from URL"> <match url="^(?!index.php)([^?#]*)(\\?([^#]*))?(#(.*))?" /> <conditions> <add input="{URL}" pattern="^/(media|skin|js)/" ignoreCase="false" negate="true" /> <add input="{REQUEST_FILENAME}" matchType="IsFile" ignoreCase="false" negate="true" /> <add input="{REQUEST_FILENAME}" matchType="IsDirectory" ignoreCase="false" negate="true" /> </conditions> <action type="Rewrite" url="index.php/{R:0}" /> </rule> </rules> </rewrite> </system.webServer> </configuration> Next, I wanted to install WordPress. I unzipped all files in folder e:\mydomain\wwwroot\wordpress Browsed to www.mydomain.com/wordpress/wp-admin/install.php, where I configured everything for my database. Everything was installed correctly. I then navigate to http://www.mydomain.com/wordpress/wp-login.php where I type my credentials. I seem to be logged in and am redirected to http://www.mydomain.com/wordpress/wp-admin/ But there I receive an empty page. I enabled detailed error message in IIS following this article: http://www.iis.net/learn/troubleshoot/diagnosing-http-errors/how-to-use-http-detailed-errors-in-iis I also checkec with Fiddler and see that I receive a 500 error: GET /wordpress/wp-admin/ HTTP/1.1 Host: www.mydomain.com Connection: keep-alive Cache-Control: max-age=0 Accept: text/html,application/xhtml+xml,application/xml;q=0.9,/;q=0.8 User-Agent: Mozilla/5.0 (Windows NT 6.1; WOW64) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/29.0.1547.76 Safari/537.36 Referer: http://www.mydomain.com/wordpress/wp-login.php Accept-Encoding: gzip,deflate,sdch Accept-Language: en-US,en;q=0.8,nl;q=0.6 Cookie: wordpress_fabec4083cf12d8de89c98e8aef4b7e3=floran%7C1381236774%7C2d8edb4fc6618f290fadb49b035cad31; wordpress_test_cookie=WP+Cookie+check; wordpress_logged_in_fabec4083cf12d8de89c98e8aef4b7e3=floran%7C1381236774%7Cbf822163926b8b8df16d0f1fefb6e02e HTTP/1.1 500 Internal Server Error Content-Type: text/html Server: Microsoft-IIS/7.5 X-Powered-By: PHP/5.4.14 X-Powered-By: ASP.NET Date: Sun, 06 Oct 2013 12:56:03 GMT Content-Length: 0 My WordPress web.config in folder e:\mydomain\wwwroot\wordpress contains: <?xml version="1.0" encoding="UTF-8"?> <configuration> <system.webServer> <rewrite> <rules> <rule name="wordpress" patternSyntax="Wildcard"> <match url="*"/> <conditions> <add input="{REQUEST_FILENAME}" matchType="IsFile" negate="true"/> <add input="{REQUEST_FILENAME}" matchType="IsDirectory" negate="true"/> </conditions> <action type="Rewrite" url="index.php"/> </rule></rules> </rewrite> </system.webServer> </configuration> I also want my WordPress articles to be available on www.mydomain.com/blog instead of www.mydomain.com/wordpress Ofcourse my admin links for Magento and Wordpress should also work. How can I configure my web.config files to achieve the above?

    Read the article

  • Browser History ASP.Net AJAX: Microsoft.Web.Preview

    - by Narendra Tiwari
    I remember in 2006 we were working on a portal for our client Venetian, Las Vegas and the portal is full of AJAX features. One of my friend facing a challange to retain browser history with all AJAX operation. In terms of user experience it is an important aspect which could not be avoided in that scenario. Well that time we have made some workarounds to achieve the same but that may not be the perfect solution. Ok.. Now with Microsoft AJAX there are a lot of such features can be achieved with optimum efficiency. Microsoft AJAX has grown its features over the past few years. Microsoft.Web.Preview.dll is an addon in conjunction with ASP.Net AJAX. It contains a control named "History" for that purpose. Source code:- http://download.microsoft.com/download/8/3/1/831ffcd7-c571-4075-b8fa-6ff678794f60/CS-ASP-ASPBrowserHistoryinAJAX_cs.zip Below is a small sample to demonstrate the control. 1/ Get dll from the above source code bin, and add reference to your web application. 2/ Rightclick on toolbox panel and Choose Item, browse assembly. now you will be able to see History control. 3/ Add below section group in web.config under <configSections> <sectionGroup name="microsoft.web.preview" type="Microsoft.Web.Preview.Configuration.PreviewSectionGroup, Microsoft.Web.Preview"> <section name="search" type="Microsoft.Web.Preview.Configuration.SearchSection, Microsoft.Web.Preview" requirePermission="false" allowDefinition="MachineToApplication"/> <section name="searchSiteMap" type="Microsoft.Web.Preview.Configuration.SearchSiteMapSection, Microsoft.Web.Preview" requirePermission="false" allowDefinition="MachineToApplication"/> <section name="diagnostics" type="Microsoft.Web.Preview.Configuration.DiagnosticsSection, Microsoft.Web.Preview" requirePermission="false" allowDefinition="MachineToApplication"/> </sectionGroup> 4/ Now create a simple webpage a textbox (txt1), button (btn1)  in an updatePanel with History control (History1). We will fill in text box and post the fom by clicking button a few times then verify if the browse history is retained. Remember button and textbox must be inside UpdatePanel and History control outside the UpdatePanel. <%@Page Language="C#" AutoEventWireup="true" CodeFile="History.aspx.cs" Inherits="History" %> <%@ Register Assembly="Microsoft.Web.Preview" Namespace="Microsoft.Web.Preview.UI.Controls" TagPrefix="cc1" %> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml" > <head runat="server"> <title>Untitled Page</title> </head> <body> <form id="form1" runat="server"> <asp:ScriptManager ID="ScriptManager1" runat="server" EnablePartialRendering="true"></asp:ScriptManager> <div> <cc1:History ID="History1" runat="server" OnNavigate="History1_Navigate"> </cc1:History> <asp:UpdatePanel ID="up1" runat="server"> <ContentTemplate> <asp:TextBox ID="txt1" runat="server"></asp:TextBox><br /> <asp:Button ID="btn1" runat="server" Text="Test" OnClick="btn1_Click" /> </ContentTemplate> <Triggers> <asp:AsyncPostBackTrigger ControlID="History1" /> </Triggers> </asp:UpdatePanel> </div> </form> </body> </html> 5/ Below code to add the textbox value in history everytime we post back using btn1 click.  protected void btn1_Click(object sender, EventArgs e) { History1.AddHistoryPoint("txtState",txt1.Text); } 6/ and finally Navigate event of History control protected void History1_Navigate(object sender, Microsoft.Web.Preview.UI.Controls.HistoryEventArgs args) { string strState = string.Empty; if (args.State.ContainsKey("txtState")) { strState = (string)args.State["txtState"]; } txt1.Text = strState; } Now all set to go :) Reference: http://www.dotnetglobe.com/2008/08/using-asp.html

    Read the article

  • how to make bridge networking with KVM work in Fedora19

    - by netllama
    I'm attempting to get several virtual machines setup on a Fedora-19 host system, with the traditional bridge network devices (br0, br1, etc). I've done this many times before with older versions of Fedora (16, 14, etc), and it just works. However, for reasons that I cannot figure out, the bridge doesn't seem to be working in Fedora19. While I can successfully connect to the outside world (local network + internet) from inside a VM, nothing can communicate with the VM from outside (local network). I'm referring to something as trivial as pinging. From inside the VM, I can ping anything successfully (0% packet loss). However, from outside the VM (on the host, or any other system on the same network), I see 100% packet loss when pinging the IP address of the VM. My first question is simply, does anyone else have this working successfully in F19? And if so, what steps did you need to follow? I'm not using NetworkManager at all, its all the network service. There are no firewalls involved anywhere (iptables & firewall services are currently disabled). Here's the current host configuration: # brctl show bridge name bridge id STP enabled interfaces br0 8000.38eaa792efe5 no em2 vnet1 br1 8000.38eaa792efe6 no em3 br2 8000.38eaa792efe7 no em4 vnet0 virbr0 8000.525400db3ebf yes virbr0-nic # more /etc/sysconfig/network-scripts/ifcfg-em2 TYPE=Ethernet BRIDGE="br0" NAME=em2 DEVICE="em2" UUID=aeaa839e-c89c-4d6e-9daa-79b6a1b919bd ONBOOT=yes HWADDR=38:EA:A7:92:EF:E5 NM_CONTROLLED="no" # more /etc/sysconfig/network-scripts/ifcfg-br0 TYPE=Bridge NM_CONTROLLED="no" BOOTPROTO=dhcp NAME=br0 DEVICE="br0" ONBOOT=yes # ifconfig em2 ;ifconfig br0 em2: flags=4163<UP,BROADCAST,RUNNING,MULTICAST> mtu 1500 inet6 fe80::3aea:a7ff:fe92:efe5 prefixlen 64 scopeid 0x20<link> ether 38:ea:a7:92:ef:e5 txqueuelen 1000 (Ethernet) RX packets 100093 bytes 52354831 (49.9 MiB) RX errors 0 dropped 0 overruns 0 frame 0 TX packets 25321 bytes 15791341 (15.0 MiB) TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0 device memory 0xf7d00000-f7e00000 br0: flags=4163<UP,BROADCAST,RUNNING,MULTICAST> mtu 1500 inet 10.31.99.226 netmask 255.255.252.0 broadcast 10.31.99.255 inet6 fe80::3aea:a7ff:fe92:efe5 prefixlen 64 scopeid 0x20<link> ether 38:ea:a7:92:ef:e5 txqueuelen 0 (Ethernet) RX packets 19619 bytes 1963328 (1.8 MiB) RX errors 0 dropped 0 overruns 0 frame 0 TX packets 11 bytes 1074 (1.0 KiB) TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0 Relevant section from /etc/libvirt/qemu/foo.xml (one of the VMs with this problem): <interface type='bridge'> <mac address='52:54:00:26:22:9d'/> <source bridge='br0'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> # ps -ef | grep qemu qemu 1491 1 82 13:25 ? 00:42:09 /usr/bin/qemu-system-x86_64 -machine accel=kvm -name cuda-linux64-build5 -S -machine pc-0.13,accel=kvm,usb=off -cpu SandyBridge,+pdpe1gb,+osxsave,+dca,+pcid,+pdcm,+xtpr,+tm2,+est,+smx,+vmx,+ds_cpl,+monitor,+dtes64,+pbe,+tm,+ht,+ss,+acpi,+ds,+vme -m 16384 -smp 6,sockets=6,cores=1,threads=1 -uuid 6e930234-bdfd-044d-2787-22d4bbbe30b1 -no-user-config -nodefaults -chardev socket,id=charmonitor,path=/var/lib/libvirt/qemu/cuda-linux64-build5.monitor,server,nowait -mon chardev=charmonitor,id=monitor,mode=control -rtc base=localtime -no-shutdown -device piix3-usb-uhci,id=usb,bus=pci.0,addr=0x1.0x2 -drive file=/var/lib/libvirt/images/cuda-linux64-build5.img,if=none,id=drive-virtio-disk0,format=raw,cache=writeback -device virtio-blk-pci,scsi=off,bus=pci.0,addr=0x4,drive=drive-virtio-disk0,id=virtio-disk0,bootindex=1 -netdev tap,fd=25,id=hostnet0,vhost=on,vhostfd=26 -device virtio-net-pci,netdev=hostnet0,id=net0,mac=52:54:00:26:22:9d,bus=pci.0,addr=0x3 -chardev pty,id=charserial0 -device isa-serial,chardev=charserial0,id=serial0 -vnc 127.0.0.1:1 -vga cirrus -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x5 I can provide additional information, if requested. thanks!

    Read the article

  • Bind a Wijmo Grid to Salesforce.com Through the Salesforce OData Connector

    - by dataintegration
    This article will explain how to connect to any RSSBus OData Connector with Wijmo's data grid using JSONP. While the example will use the Salesforce Connector, the same process can be followed for any of the RSSBus OData Connectors. Step 1: Download and install both the Salesforce Connector from RSSBus and the Wijmo javascript library. Step 2: Next you will want to configure the Salesforce Connector to connect with your Salesforce account. If you browse to the Help tab in the Salesforce Connector application, there is a link to the Getting Started Guide which will walk you through setting up the Salesforce Connector. Step 3: Once you have successfully configured the Salesforce Connector application, you will want to open a Wijmo sample grid file to edit. This example will use the overview.html grid found in the Samples folder. Step 4: First, we will wrap the jQuery document ready function in a callback function for the JSONP service. In this example, we will wrap this in function called fnCallback which will take a single object args. <script id="scriptInit" type="text/javascript"> function fnCallback(args) { $(document).ready(function () { $("#demo").wijgrid({ ... }); }); }; </script> Step 5: Next, we need to format the columns object in a format that Wijmo's data grid expects. This is done by adding the headerText: element for each column. <script id="scriptInit" type="text/javascript"> function fnCallback(args) { var columns = []; for (var i = 0; i < args.columnnames.length; i++){ var col = { headerText: args.columnnames[i]}; columns.push(col); } $(document).ready(function () { $("#demo").wijgrid({ ... }); }); }; </script> Step 6: Now the wijgrid parameters are ready to be set. In this example, we will set the data input parameter to the args.data object and the columns input parameter to our newly created columns object. The resulting javascript function should look like this: <script id="scriptInit" type="text/javascript"> function fnCallback(args) { var columns = []; for (var i = 0; i < args.columnnames.length; i++){ var col = { headerText: args.columnnames[i]}; columns.push(col); } $(document).ready(function () { $("#demo").wijgrid({ allowSorting: true, allowPaging: true, pageSize: 10, data: args.data, columns: columns }); }); }; </script> Step 7: Finally, we need to add the JSONP reference to our Salesforce Connector's data table. You can find this by clicking on the Settings tab of the Salesforce Connector. Once you have found the JSONP URL, you will need to supply a valid table name that you want to connect with Wijmo. In this example, we will connect to the Lead table. You will also need to add authentication options in this step. In the example we will append the authtoken of the user who has access to the Salesforce Connector using the @authtoken query string parameter. IMPORTANT: This is not secure and will expose the authtoken of the user whose authtoken you supply in this step. There are other ways to secure the user's authtoken, but this example uses a query string parameter for simplicity. <script src="http://localhost:8181/sfconnector/data/conn/Lead.rsd?@jsonp=fnCallback&sql:query=SELECT%20*%20FROM%20Lead&@authtoken=<myAuthToken>" type="text/javascript"></script> Step 8: Now, we are done. If you point your browser to the URL of the sample, you should see your Salesforce.com leads in a Wijmo data grid.

    Read the article

  • Users loggin to 3Com switches authenticated by radius not getting admin priv and no access available

    - by 3D1L
    Hi, Following the setup that I have for my Cisco devices, I got some basic level of functionality authenticating users that loggin to 3Com switches authenticated against a RADIUS server. Problem is that I can not get the user to obtain admin privileges. I'm using Microsoft's IAS service. According to 3Com documentation when configuring the access policy on IAS the value of 010600000003 have to be used to specify admin access level. That value have to be input in the Dial-in profile section: 010600000003 - indicates admin privileges 010600000002 - manager 010600000001 - monitor 010600000000 - visitor Here is the configuration on the switch: radius scheme system server-type standard primary authentication XXX.XXX.XXX.XXX accounting optional key authentication XXXXXX key accounting XXXXXX domain system scheme radius-scheme system local-user admin service-type ssh telnet terminal level 3 local-user manager service-type ssh telnet terminal level 2 local-user monitor service-type ssh telnet terminal level 1 The configuration is working with the IAS server because I can check user login events with the Eventviewer tool. Here is the output of the DISPLAY RADIUS command at the switch: [4500]disp radius SchemeName =system Index=0 Type=standard Primary Auth IP =XXX.XXX.XXX.XXX Port=1645 State=active Primary Acct IP =127.0.0.1 Port=1646 State=active Second Auth IP =0.0.0.0 Port=1812 State=block Second Acct IP =0.0.0.0 Port=1813 State=block Auth Server Encryption Key= XXXXXX Acct Server Encryption Key= XXXXXX Accounting method = optional TimeOutValue(in second)=3 RetryTimes=3 RealtimeACCT(in minute)=12 Permitted send realtime PKT failed counts =5 Retry sending times of noresponse acct-stop-PKT =500 Quiet-interval(min) =5 Username format =without-domain Data flow unit =Byte Packet unit =1 Total 1 RADIUS scheme(s). 1 listed Here is the output of the DISPLAY DOMAIN and DISPLAY CONNECTION commands after users log into the switch: [4500]display domain 0 Domain = system State = Active RADIUS Scheme = system Access-limit = Disable Domain User Template: Idle-cut = Disable Self-service = Disable Messenger Time = Disable Default Domain Name: system Total 1 domain(s).1 listed. [4500]display connection Index=0 ,Username=admin@system IP=0.0.0.0 Index=2 ,Username=user@system IP=xxx.xxx.xxx.xxx On Unit 1:Total 2 connections matched, 2 listed. Total 2 connections matched, 2 listed. [4500] Here is the DISP RADIUS STATISTICS: [4500] %Apr 2 00:23:39:957 2000 4500 SHELL/5/LOGIN:- 1 - ecajigas(xxx.xxx.xxx.xxx) in un it1 logindisp radius stat state statistic(total=1048): DEAD=1046 AuthProc=0 AuthSucc=0 AcctStart=0 RLTSend=0 RLTWait=2 AcctStop=0 OnLine=2 Stop=0 StateErr=0 Received and Sent packets statistic: Unit 1........................................ Sent PKT total :4 Received PKT total:1 Resend Times Resend total 1 1 2 1 Total 2 RADIUS received packets statistic: Code= 2,Num=1 ,Err=0 Code= 3,Num=0 ,Err=0 Code= 5,Num=0 ,Err=0 Code=11,Num=0 ,Err=0 Running statistic: RADIUS received messages statistic: Normal auth request , Num=1 , Err=0 , Succ=1 EAP auth request , Num=0 , Err=0 , Succ=0 Account request , Num=1 , Err=0 , Succ=1 Account off request , Num=0 , Err=0 , Succ=0 PKT auth timeout , Num=0 , Err=0 , Succ=0 PKT acct_timeout , Num=3 , Err=1 , Succ=2 Realtime Account timer , Num=0 , Err=0 , Succ=0 PKT response , Num=1 , Err=0 , Succ=1 EAP reauth_request , Num=0 , Err=0 , Succ=0 PORTAL access , Num=0 , Err=0 , Succ=0 Update ack , Num=0 , Err=0 , Succ=0 PORTAL access ack , Num=0 , Err=0 , Succ=0 Session ctrl pkt , Num=0 , Err=0 , Succ=0 RADIUS sent messages statistic: Auth accept , Num=0 Auth reject , Num=0 EAP auth replying , Num=0 Account success , Num=0 Account failure , Num=0 Cut req , Num=0 RecError_MSG_sum:0 SndMSG_Fail_sum :0 Timer_Err :0 Alloc_Mem_Err :0 State Mismatch :0 Other_Error :0 No-response-acct-stop packet =0 Discarded No-response-acct-stop packet for buffer overflow =0 The other problem is that when the RADIUS server is not available I can not log in to the switch. The switch have 3 local accounts but none of them works. How can I specify the switch to use the local accounts in case that the RADIUS service is not available?

    Read the article

  • Generic Sorting using C# and Lambda Expression

    - by Haitham Khedre
    Download : GenericSortTester.zip I worked in this class from long time and I think it is a nice piece of code that I need to share , it might help other people searching for the same concept. this will help you to sort any collection easily without needing to write special code for each data type , however if you need special ordering you still can do it , leave a comment and I will see if I need to write another article to cover the other cases. I attached also a fully working example to make you able to see how do you will use that .     public static class GenericSorter { public static IOrderedEnumerable<T> Sort<T>(IEnumerable<T> toSort, Dictionary<string, SortingOrder> sortOptions) { IOrderedEnumerable<T> orderedList = null; foreach (KeyValuePair<string, SortingOrder> entry in sortOptions) { if (orderedList != null) { if (entry.Value == SortingOrder.Ascending) { orderedList = orderedList.ApplyOrder<T>(entry.Key, "ThenBy"); } else { orderedList = orderedList.ApplyOrder<T>(entry.Key,"ThenByDescending"); } } else { if (entry.Value == SortingOrder.Ascending) { orderedList = toSort.ApplyOrder<T>(entry.Key, "OrderBy"); } else { orderedList = toSort.ApplyOrder<T>(entry.Key, "OrderByDescending"); } } } return orderedList; } private static IOrderedEnumerable<T> ApplyOrder<T> (this IEnumerable<T> source, string property, string methodName) { ParameterExpression param = Expression.Parameter(typeof(T), "x"); Expression expr = param; foreach (string prop in property.Split('.')) { expr = Expression.PropertyOrField(expr, prop); } Type delegateType = typeof(Func<,>).MakeGenericType(typeof(T), expr.Type); LambdaExpression lambda = Expression.Lambda(delegateType, expr, param); MethodInfo mi = typeof(Enumerable).GetMethods().Single( method => method.Name == methodName && method.IsGenericMethodDefinition && method.GetGenericArguments().Length == 2 && method.GetParameters().Length == 2) .MakeGenericMethod(typeof(T), expr.Type); return (IOrderedEnumerable<T>)mi.Invoke (null, new object[] { source, lambda.Compile() }); } } .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; }

    Read the article

  • BizTalk 2009 - Pipeline Component Wizard

    - by Stuart Brierley
    Recently I decided to try out the BizTalk Server Pipeline Component Wizard when creating a new pipeline component for BizTalk 2009. There are different versions of the wizard available, so be sure to download the appropriate version for the BizTalk environment that you are working with. Following the download and expansion of the zip file, you should be left with a Visual Studio solution.  Open this solution and build the project. Following this installation is straight foward - locate and run the built setup.exe file in the PipelineComponentWizard Setup project and click through the small number of installation screens. Once you have completed installation you will be ready to use the wizard in Visual Studio to create your BizTalk Pipeline Component. Start by creating a new project, selecting BizTalk Projects then BizTalk Server Pipeline Component.  You will then be presented with the splash screen. The next step is General Setup, where you will detail the classname, namespace, pipeline and component types, and the implementation language for your Pipeline Component. The options for pipeline type are Receive, Send or Any. Depending on the pipeline type chosen there are different options presented for the component type, matching those available within the BizTalk Pipelines themselves: Receive - Decoder, Disassembling Parser, Validate, Party Resolver, Any. Send -  Encoder, Assembling Serializer, Any. Any - Any. The options for implementation language are C# or VB.Net Next you must set up the UI settings - these are the settings that affect the appearance of the pipeline component within Visual Studio. You must detail the component name, version, description and icon.  Next is the definition of the variables that the pipeline component will use.  The values for these variables will be defined in Visual Studio when creating a pipeline. The options for each variable you require are: Designer Property - The name of the variable. Data Type - String, Boolean, Integer, Long, Short, Schema List, Schema With None Clicking finish now will complete the wizard stage of the creation of your pipeline component. Once the wizard has completed you will be left with a BizTalk Server Pipeline Component project containing a skeleton code file for you to complete.   Within this code file you will mainly be interested in the execute method, which is left mostly empty ready for you to implement your custom pipeline code:          #region IComponent members         /// <summary>         /// Implements IComponent.Execute method.         /// </summary>         /// <param name="pc">Pipeline context</param>         /// <param name="inmsg">Input message</param>         /// <returns>Original input message</returns>         /// <remarks>         /// IComponent.Execute method is used to initiate         /// the processing of the message in this pipeline component.         /// </remarks>         public Microsoft.BizTalk.Message.Interop.IBaseMessage Execute(Microsoft.BizTalk.Component.Interop.IPipelineContext pc, Microsoft.BizTalk.Message.Interop.IBaseMessage inmsg)         {             //             // TODO: implement component logic             //             // this way, it's a passthrough pipeline component             return inmsg;         }         #endregion Once you have implemented your custom code, build and compile your Custom Pipeline Component then add the compiled .dll to C:\Program Files\Microsoft BizTalk Server 2009\Pipeline Components . When creating a new pipeline, in Visual Studio reset the toolbox and the custom pipeline component should appear ready for you to use in your Biztalk Pipeline. Drop the pipeline component into the relevant pipeline stage and configure the component properties (the variables defined in the wizard). You can now deploy and use the pipeline as you would any other custom pipeline.

    Read the article

  • SFML fail to load image as texture

    - by zyeek
    I have come to a problem with the code below ... Using SFML 2.0 #include <SFML/Graphics.hpp> #include <iostream> #include <list> int main() { float speed = 5.0f; // create the window sf::RenderWindow window(sf::VideoMode(sf::VideoMode::getDesktopMode().height - 300, 800), "Bricks"); // Set game window position on the screen window.setPosition( sf::Vector2i(sf::VideoMode::getDesktopMode().width/4 + sf::VideoMode::getDesktopMode().width/16 , 0) ); // Allow library to accept repeatitive key presses (i.e. holding key) window.setKeyRepeatEnabled(true); // Hide mouse cursor //window.setMouseCursorVisible(false); // Limit 30 frames per sec; the minimum for all games window.setFramerateLimit(30); sf::Texture texture; if (!texture.loadFromFile("tile.png", sf::IntRect(0, 0, 125, 32))) { std::cout<<"Could not load image\n"; return -1; } // Empty list of sprites std::list<sf::Sprite> spriteContainer; bool gameFocus = true; // run the program as long as the window is open while (window.isOpen()) { sf::Vector2i mousePos = sf::Mouse::getPosition(window); // check all the window's events that were triggered since the last iteration of the loop sf::Event event; while (window.pollEvent(event)) { float offsetX = 0.0f, offsetY = 0.0f; if(event.type == sf::Event::GainedFocus) gameFocus = !gameFocus; else if(event.type == sf::Event::LostFocus) gameFocus = !gameFocus; if(event.type == sf::Event::KeyPressed) { if (event.key.code == sf::Keyboard::Space) { if(gameFocus) { // Create sprite and add features before putting it into container sf::Sprite sprite(texture); sprite.scale(.9f,.7f); sf::Vector2u textSize = texture.getSize(); sprite.setPosition(sf::Vector2f(mousePos.x-textSize.x/2.0f, mousePos.y - textSize.y/2.0f)); spriteContainer.push_front(sprite); } } if(event.key.code == sf::Keyboard::P) std::cout << spriteContainer.size() << std::endl; if( event.key.code == sf::Keyboard::W ) offsetY -= speed; if( event.key.code == sf::Keyboard::A ) offsetX -= speed; if( event.key.code == sf::Keyboard::S ) offsetY += speed; if( event.key.code == sf::Keyboard::D ) offsetX += speed; } // "close requested" event: we close the window if (event.type == sf::Event::Closed || event.key.code == sf::Keyboard::Escape) window.close(); // Move all sprites synchronously for (std::list<sf::Sprite>::iterator sprite = spriteContainer.begin(); sprite != spriteContainer.end(); ++sprite) sprite->move(offsetX, offsetY); //sprite.move(offsetX,offsetY); } // clear the window with black color window.clear(sf::Color::Black); // draw everything here... // window.draw(...); // Draw all sprites in the container for (std::list<sf::Sprite>::iterator sprite = spriteContainer.begin(); sprite != spriteContainer.end(); ++sprite) window.draw(*sprite); // end the current frame window.display(); } return 0; } A couple weeks ago it worked flawlessly to my expectation, but now that I come back to it and I am having problems importing the image as a texture "tile.png". I don't understand why this is evening happening and the only message I get via the terminal is "Cannot load image ..." then a bunch of random characters. My libraries are for sure working, but now I am not sure why the image is not loading. My image is in the same directory as with my .h and .cpp files. This is an irritating problem that keep coming up for some reason and is always a problem to fix it. I import my libraries via my own directory "locals" which contain many APIs, but I specifically get SFML, and done appropriately as I am able to open a window and many other stuff.

    Read the article

  • Templated Razor Delegates – Phil Haack

    - by nmarun
    This post is largely based off of Phil Haack’s article titled Templated Razor Delegates. I strongly recommend reading this article first. Here’s a sample code for the same, so you can have a look at. I also have a custom type being rendered as a table. 1: // my custom type 2: public class Device 3: { 4: public int Id { get; set; } 5: public string Name { get; set; } 6: public DateTime MfgDate { get; set; } 7: } Now I can write an extension method just for this type. 1: public static class RazorExtensions 2: { 3: public static HelperResult List(this IList<Models.Device> devices, Func<Models.Device, HelperResult> template) 4: { 5: return new HelperResult(writer => 6: { 7: foreach (var device in devices) 8: { 9: template(device).WriteTo(writer); 10: } 11: }); 12: } 13: // ... 14: } Modified my view to make it a strongly typed one and included html to render my custom type collection in a table. 1: @using TemplatedRazorDelegates 2: @model System.Collections.Generic.IList<TemplatedRazorDelegates.Models.Device> 3:  4: @{ 5: ViewBag.Title = "Home Page"; 6: } 7:  8: <h2>@ViewBag.Message</h2> 9:  10: @{ 11: var items = new[] { "one", "two", "three" }; 12: IList<int> ints = new List<int> { 1, 2, 3 }; 13: } 14:  15: <ul> 16: @items.List(@<li>@item</li>) 17: </ul> 18: <ul> 19: @ints.List(@<li>@item</li>) 20: </ul> 21:  22: <table> 23: <tr><th>Id</th><th>Name</th><th>Mfg Date</th></tr> 24: @Model.List(@<tr><td>@item.Id</td><td>@item.Name</td><td>@item.MfgDate.ToShortDateString()</td></tr>) 25: </table> We get intellisense as well! Just added some items in the action method of the controller: 1: public ActionResult Index() 2: { 3: ViewBag.Message = "Welcome to ASP.NET MVC!"; 4: IList<Device> devices = new List<Device> 5: { 6: new Device {Id = 1, Name = "abc", MfgDate = new DateTime(2001, 10, 19)}, 7: new Device {Id = 2, Name = "def", MfgDate = new DateTime(2011, 1, 1)}, 8: new Device {Id = 3, Name = "ghi", MfgDate = new DateTime(2003, 3, 15)}, 9: new Device {Id = 4, Name = "jkl", MfgDate = new DateTime(2007, 6, 6)} 10: }; 11: return View(devices); 12: } Running this I get the output as: Absolutely brilliant! Thanks to both Phil Haack and to David Fowler for bringing this out to us. Download the code for this from here. Verdict: RazorViewEngine.Points += 1;

    Read the article

  • How to Use Sparklines in Excel 2010

    - by DigitalGeekery
    One of the cool features of Excel 2010 is the addition of Sparklines. A Sparkline is basically a little chart displayed in a cell representing your selected data set that allows you to quickly and easily spot trends at a glance. Inserting Sparklines on your Spreadsheet You will find the Sparklines group located on the Insert tab.   Select the cell or cells where you wish to display your Sparklines. Select the type of Sparkline you’d like to add to your spreadsheet. You’ll notice there are three types of Sparklines, Line, Column, and Win/Loss. We’ll select Line for our example. A Create Sparklines pops up and will prompt you to enter a Data Range you are using to create the Sparklines. You’ll notice that the location range (the range where the Sparklines will appear) is already filled in. You can type in the data range manually, or click and drag with your mouse across to select the data range. This will auto-fill the data range for you. Click OK when you are finished.   You will see your Sparklines appear in the desired cells.   Customizing Sparklines Select the one of more of the Sparklines to reveal the Design tab. You can display certain value points like high and low points, negative points, and first and last points by selecting the corresponding options from the Show group. You can also mark all value points by selecting  Markers. Select your desired Sparklines and click one of the included styles from the Style group on the Design tab. Click the down arrow on the lower right corner of the box to display additional pre-defined styles…   or select Sparkline Color or Marker Color options to fully customize your Sparklines. The Axis options allow additional options such as Date Axis Type, Plotting Data Left to Right, and displaying an axis point to represent the zero line in your data with Show Axis. Column Sparklines Column Sparklines display your data in individual columns as opposed to the Line view we’ve been using for our examples. Win/Loss Sparklines Win/Loss shows a basic positive or negative representation of your data set.   You can easily switch between different Sparkline types by simply selecting the current cells (individually or the entire group), and then clicking the desired type on the Design tab. For those that may be more visually oriented, Sparklines can be a wonderful addition to any spreadsheet. Are you just getting started with Office 2010? Check out some of our other great Excel posts such as how to copy worksheets, print only selected areas of a spreadsheet, and how to share data with Excel in Office 2010. Similar Articles Productive Geek Tips Convert a Row to a Column in Excel the Easy WayShare Access Data with Excel in Office 2010Make Excel 2007 Print Gridlines In Workbook FileMake Excel 2007 Always Save in Excel 2003 FormatConvert Older Excel Documents to Excel 2007 Format TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Office 2010 reviewed in depth by Ed Bott FoxClocks adds World Times in your Statusbar (Firefox) Have Fun Editing Photo Editing with Citrify Outlook Connector Upgrade Error Gadfly is a cool Twitter/Silverlight app Enable DreamScene in Windows 7

    Read the article

  • How to check if a cdrom is in the tray remotely (via ssh)?

    - by adempewolff
    I have a server running Ubuntu 10.04 (it's on the other side of the world and I haven't built up the wherewithal to upgrade it remotely yet) and I have been told that there is a CD in one of it's two CD drives. I want to rip an image of the cd and then download it to my local computer (I don't need help with either of these steps). However, I cannot seem to confirm whether or not there actually is a CD in the drive as I was told. It did not automatically mount anywhere (which I'm thinking might just be a result of it being a headless server not running X, nautilus, or any of the other nice user friendly things). There are two CD drives connected via SCSI: austin@austinvpn:/proc/scsi$ cat /proc/scsi/scsi Attached devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: ATA Model: WDC WD400EB-75CP Rev: 06.0 Type: Direct-Access ANSI SCSI revision: 05 Host: scsi1 Channel: 00 Id: 00 Lun: 00 Vendor: Lite-On Model: LTN486S 48x Max Rev: YDS6 Type: CD-ROM ANSI SCSI revision: 05 Host: scsi1 Channel: 00 Id: 01 Lun: 00 Vendor: SAMSUNG Model: CD-R/RW SW-248F Rev: R602 Type: CD-ROM ANSI SCSI revision: 05 However when I try mounting either of these devices (and every other device that could possibly be the cd-drive), it says no medium found: austin@austinvpn:/proc/scsi$ sudo mount -t iso9660 /dev/scd1 /cdrom mount: no medium found on /dev/sr1 austin@austinvpn:/proc/scsi$ sudo mount -t iso9660 /dev/scd0 /cdrom mount: no medium found on /dev/sr0 austin@austinvpn:/proc/scsi$ sudo mount -t iso9660 /dev/cdrom /cdrom mount: no medium found on /dev/sr1 austin@austinvpn:/proc/scsi$ sudo mount -t iso9660 /dev/cdrom1 /cdrom mount: no medium found on /dev/sr0 austin@austinvpn:/proc/scsi$ sudo mount -t iso9660 /dev/cdrw /cdrom mount: no medium found on /dev/sr1 Here are the contents of my /dev folder: austin@austinvpn:/proc/scsi$ ls /dev agpgart loop6 ram6 tty10 tty38 tty8 austinvpn loop7 ram7 tty11 tty39 tty9 block lp0 ram8 tty12 tty4 ttyS0 bsg mapper ram9 tty13 tty40 ttyS1 btrfs-control mcelog random tty14 tty41 ttyS2 bus mem rfkill tty15 tty42 ttyS3 cdrom net root tty16 tty43 urandom cdrom1 network_latency rtc tty17 tty44 usbmon0 cdrw network_throughput rtc0 tty18 tty45 usbmon1 char null scd0 tty19 tty46 usbmon2 console oldmem scd1 tty2 tty47 usbmon3 core parport0 sda tty20 tty48 usbmon4 cpu_dma_latency pktcdvd sda1 tty21 tty49 vcs disk port sda2 tty22 tty5 vcs1 dri ppp sda5 tty23 tty50 vcs2 ecryptfs psaux sg0 tty24 tty51 vcs3 fb0 ptmx sg1 tty25 tty52 vcs4 fd pts sg2 tty26 tty53 vcs5 full ram0 shm tty27 tty54 vcs6 fuse ram1 snapshot tty28 tty55 vcs7 hpet ram10 snd tty29 tty56 vcsa input ram11 sndstat tty3 tty57 vcsa1 kmsg ram12 sr0 tty30 tty58 vcsa2 log ram13 sr1 tty31 tty59 vcsa3 loop0 ram14 stderr tty32 tty6 vcsa4 loop1 ram15 stdin tty33 tty60 vcsa5 loop2 ram2 stdout tty34 tty61 vcsa6 loop3 ram3 tty tty35 tty62 vcsa7 loop4 ram4 tty0 tty36 tty63 vga_arbiter loop5 ram5 tty1 tty37 tty7 zero And here is my fstab file: austin@austinvpn:/proc/scsi$ cat /etc/fstab # /etc/fstab: static file system information. # # Use 'blkid -o value -s UUID' to print the universally unique identifier # for a device; this may be used with UUID= as a more robust way to name # devices that works even if disks are added and removed. See fstab(5). # # <file system> <mount point> <type> <options> <dump> <pass> proc /proc proc nodev,noexec,nosuid 0 0 /dev/mapper/austinvpn-root / ext4 errors=remount-ro 0 1 # /boot was on /dev/sda1 during installation UUID=ed5520ae-c690-4ce6-881e-3598f299be06 /boot ext2 defaults 0 2 /dev/mapper/austinvpn-swap_1 none swap sw 0 0 Am I missing something/doing something wrong, or is there just no CD in the drive or is the drive possibly broken? Is there any nice command to list devices with mountable media? Thanks in advance for any help!

    Read the article

  • Tweaking Remote Control (In-Kernel LIRC)

    - by Geoff
    I've recently rebuilt my MythTV box using Mythbuntu 12.04, to take advantage of newer hardware (Ivy Bridge). On my previous build I used lirc to manage the remote, i.e. the mapping of key codes - keypresses - application keys; it was quite a journey to learn it all, and I ended up fairly comfortable with how it all worked. What I have: I have a cheap Chinavasion remote and USB dongle, which I've found several articles on; these largely revolve around working with XBMC (interesting, but I don't think directly applicable) and also around getting a Harmony remote to work (it's a Chinavasion CVSB-983 - very useful, since I needed this to get my Harmony 900 working). Mythbuntu 12.04 64-bit MythTV 0.25 (likely irrelevant) How it is right now When I plug this in, it 'just works'. Which is great, except that Ubuntu uses it natively, and prevents some of the button presses from getting through to Myth. For example, I can send a button from the remote that equates to Ctrl-Alt-A (which I assume Ubuntu isn't interested in), and then trap that in Mythfrontend, but the remote's Play button is caught by Ubuntu (which displays a large circle with a line though it, as there's no media player loaded). I understand that this is because lirc is merged into the kernel now, and I like that. What I've done so far: Found the device using lsusb: $ lsusb Bus 001 Device 004: ID 073a:2230 Chaplet Systems, Inc. infrared dongle for remote Found the event device number: $ cat /proc/bus/input/devices I: Bus=0003 Vendor=073a Product=2230 Version=0110 N: Name="HID 073a:2230" P: Phys=usb-0000:00:1a.0-1.2/input0 S: Sysfs=/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2:1.0/input/input5 U: Uniq= H: Handlers=sysrq kbd mouse1 event5 js0 B: PROP=0 B: EV=10001f B: KEY=4c37fff072ff32d bf54445600000000 ffffffffff 30c100b17c007 ffa67bfad951dfff febeffdfffefffff fffffffffffffffe B: REL=343 B: ABS=100030000 B: MSC=10 Tested the input with evtest (I pressed Play): $ sudo evtest /dev/input/event5 Input driver version is 1.0.1 Input device ID: bus 0x3 vendor 0x73a product 0x2230 version 0x110 Input device name: "HID 073a:2230" Supported events: Event type 0 (EV_SYN) Event type 1 (EV_KEY) Event code 1 (KEY_ESC) Event code 2 (KEY_1) Event code 3 (KEY_2) Event code 4 (KEY_3) Event code 5 (KEY_4) Event code 6 (KEY_5) Event code 7 (KEY_6) <------------snipped lots of 'Event code' lines------------> Testing ... (interrupt to exit) Event: time 1336435683.230656, -------------- SYN_REPORT ------------ Event: time 1336435683.246648, type 4 (EV_MSC), code 4 (MSC_SCAN), value c00cd Event: time 1336435683.246652, type 1 (EV_KEY), code 164 (KEY_PLAYPAUSE), value 0 Event: time 1336435683.246655, -------------- SYN_REPORT ------------ Tested showkey, again for the Play key: $ sudo showkey -s kb mode was RAW [ if you are trying this under X, it might not work since the X server is also reading /dev/console ] press any key (program terminates 10s after last keypress)... 0xe0 0x22 0xe0 0xa2 What I want: I'd like a way to scan the incoming button presses, if the above method isn't correct. I'd like to either remap each button press to something that Ubuntu/Unity will ignore, or even better pass the keypress directly to Myth (I suspect this later is only possible with lirc, but I could be wrong). I would really like to do this with the in-kernel drivers, i.e. without explicitly loading lirc; if that's the way the world is going, I'd rather find a way to map the current behaviour to what I want, rather than forcing the 'old' arrangement of loading lirc outside the kernel. Learning something new is also worthwhile! My guess: I'm assuming that this will require using setkeycodes, but have had trouble finding enough information to configure this. Any help greatly appreciated!

    Read the article

  • Restrict number of characters to be typed for af:autoSuggestBehavior

    - by Arunkumar Ramamoorthy
    When using AutoSuggestBehavior for a UI Component, the auto suggest list is displayed as soon as the user starts typing in the field. In this article, we will find how to restrict the autosuggest list to be displayed till the user types in couple of characters. This would be more useful in the low latency networks and also the autosuggest list is bigger. We could display a static message to let the user know that they need to type in more characters to get a list for picking a value from. Final output we would expect is like the below image Lets see how we can implement this. Assuming we have an input text for the users to enter the country name and an autosuggest behavior is added to it. <af:inputText label="Country" id="it1"> <af:autoSuggestBehavior /> </af:inputText> Also, assuming we have a VO (we'll name it as CountryView for this example), with a view criteria to filter out the VO based on the bind variable passed. Now, we would generate View Impl class from the java node (including bind variables) and then expose the setter method of the bind variable to client interface. In the View layer, we would create a tree binding for the VO and the method binding for the setter method of the bind variable exposed above, in the pagedef file As we've already added an input text and an autosuggestbehavior for the test, we would not need to build the suggested items for the autosuggest list.Let us add a method in the backing bean to return us List of select items to be bound to the autosuggest list. padding: 5px; background-color: #fbfbfb; min-height: 40px; width: 544px; height: 168px; overflow: auto;"> public List onSuggest(String searchTerm) { ArrayList<SelectItem> selectItems = new ArrayList<SelectItem>(); if(searchTerm.length()>1) { //get access to the binding context and binding container at runtime BindingContext bctx = BindingContext.getCurrent(); BindingContainer bindings = bctx.getCurrentBindingsEntry(); //set the bind variable value that is used to filter the View Object //query of the suggest list. The View Object instance has a View //Criteria assigned OperationBinding setVariable = (OperationBinding) bindings.get("setBind_CountryName"); setVariable.getParamsMap().put("value", searchTerm); setVariable.execute(); //the data in the suggest list is queried by a tree binding. JUCtrlHierBinding hierBinding = (JUCtrlHierBinding) bindings.get("CountryView1"); //re-query the list based on the new bind variable values hierBinding.executeQuery(); //The rangeSet, the list of queries entries, is of type //JUCtrlValueBndingRef. List<JUCtrlValueBindingRef> displayDataList = hierBinding.getRangeSet(); for (JUCtrlValueBindingRef displayData : displayDataList){ Row rw = displayData.getRow(); //populate the SelectItem list selectItems.add(new SelectItem( (String)rw.getAttribute("Name"), (String)rw.getAttribute("Name"))); } } else{ SelectItem a = new SelectItem("","Type in two or more characters..","",true); selectItems.add(a); } return selectItems; } So, what we are doing in the above method is, to check the length of the search term and if it is more than 1 (i.e 2 or more characters), the return the actual suggest list. Otherwise, create a read only select item new SelectItem("","Type in two or more characters..","",true); and add it to the list of suggested items to be displayed. The last parameter for the SelectItem (boolean) is to make it as readOnly, so that users would not be able to select this static message from the displayed list. Finally, bind this method to the input text's autosuggestbehavior's suggestedItems property. <af:inputText label="Country" id="it1"> <af:autoSuggestBehavior suggestedItems="#{AutoSuggestBean.onSuggest}"/> </af:inputText>

    Read the article

  • How to Open Any Folder as a Project in the NetBeans Platform

    - by Geertjan
    Typically, as described in the NetBeans Project Type Tutorial, you'll define a project type based on the presence of a file (e.g., "project.xml" or "customer.txt" or something like that) in a folder. I.e., if the file is there, then its parent, i.e., the folder that contains the file, is a project and should be opened in your application. However, in some scenarios (as with the HTML5 project type introduced in NetBeans IDE 7.3), the user should be able to open absolutely any folder at all into the application. How to create a project type that is that liberal? Here you go, the only condition that needs to be true is that the selected item in the "Open Project" dialog is a folder, as defined in the "isProject" method below. Nothing else. That's it. If you select a folder, it will be opened in your application, displaying absolutely everything as-is (since below there's no ProjectLogicalView defined): import java.beans.PropertyChangeListener; import java.io.IOException; import javax.swing.Icon; import org.netbeans.api.project.Project; import org.netbeans.api.project.ProjectInformation; import org.netbeans.spi.project.ProjectFactory; import org.netbeans.spi.project.ProjectState; import org.openide.filesystems.FileObject; import org.openide.loaders.DataFolder; import org.openide.loaders.DataObjectNotFoundException; import org.openide.nodes.FilterNode; import org.openide.util.Exceptions; import org.openide.util.ImageUtilities; import org.openide.util.Lookup; import org.openide.util.lookup.Lookups; import org.openide.util.lookup.ServiceProvider; @ServiceProvider(service = ProjectFactory.class) public class FolderProjectFactory implements ProjectFactory { @Override public boolean isProject(FileObject projectDirectory) { return DataFolder.findFolder(projectDirectory) != null; } @Override public Project loadProject(FileObject dir, ProjectState state) throws IOException { return isProject(dir) ? new FolderProject(dir) : null; } @Override public void saveProject(Project prjct) throws IOException, ClassCastException { // leave unimplemented for the moment } private class FolderProject implements Project { private final FileObject projectDir; private Lookup lkp; private FolderProject(FileObject dir) { this.projectDir = dir; } @Override public FileObject getProjectDirectory() { return projectDir; } @Override public Lookup getLookup() { if (lkp == null) { lkp = Lookups.fixed(new Object[]{ new Info(), }); } return lkp; } private final class Info implements ProjectInformation { @Override public Icon getIcon() { Icon icon = null; try { icon = ImageUtilities.image2Icon( new FilterNode(DataFolder.find( getProjectDirectory()).getNodeDelegate()).getIcon(1)); } catch (DataObjectNotFoundException ex) { Exceptions.printStackTrace(ex); } return icon; } @Override public String getName() { return getProjectDirectory().getName(); } @Override public String getDisplayName() { return getName(); } @Override public void addPropertyChangeListener(PropertyChangeListener pcl) { //do nothing, won't change } @Override public void removePropertyChangeListener(PropertyChangeListener pcl) { //do nothing, won't change } @Override public Project getProject() { return FolderProject.this; } } } } Even the ProjectInformation implementation really isn't needed at all, since it provides nothing more than the icon in the "Open Project" dialog, the rest (i.e., the display name in the "Open Project" dialog) is provided by default regardless of whether you have a ProjectInformation implementation or not.

    Read the article

  • Desktop Applications Versus Web Applications

    Up until the advent of the internet programmers really only developed one type of application used by end-users.  This type of application was called a desktop application. As the name implies, these applications ran strictly from a desktop computer, and were limited by the resources available to the computer. Initially, this type of applications did not need resources outside of the scope of the computer in which they installed. The problem with this type of application is that if multiple end-users need to access the same desktop application, then the application must be installed on the end-user’s computer. In this age of software development security was not as big of a concern as it is today with other types of applications. This is primarily due to the fact that an end-user must have access to the computer where the software is installed in order for them to access the application. In addition, developers could also password protect the application just in case an authorized end-user was able to gain access to the computer. With the birth of the internet a second form of application emerged because developers were trying to solve inherent issues with the preexisting desktop application. One of the solutions to overcome some of the short comings of desktop applications is the web application. Web applications are hosted on a centralized server and clients only need to have network access and a web browser in order to access the application. Because a web application can be installed on a remote server it removes the need for individual installations of the same application on each end-user’s computer.  The main benefits to an application being hosted on a server is increased accessibility to the application due to the fact that nothing has to be installed on a desktop computer for an end-user to be able to access the application. In addition, web applications are much easier to maintain because any change to the application is applied on the server and is inherently applied to any end-user trying to use the application. This removes the time needed to install and maintain individual installations of a desktop application. However with the increased accessibility there are additional costs that are incurred compared to a desktop application because of the additional cost and maintenance of a server hosting the application. Typically, after a desktop application is purchased there are no additional reoccurring fees associated with the application.  When developing a web based application there are additional considerations that must be addressed compared to a desktop application. The added benefit of increased accessibility also now adds a new failure point when trying to gain access to an application. An end-user now must have network connectivity in order to access the application. This issue is not a concern for desktop applications because there resources are typically bound to the computer in which they run. Since the availability of an application is increased with the use of the client-server model in a web based application, additional security concerns now come in to play. As stated before a, desktop application is bound to the accessibility of the end-user to the computer that the application is installed. This is not the case with web based applications because they potentially could have access from anywhere with the proper internet/network connection. Additional security steps are required to insure the integrity of the application and its data. Examples of these steps include and are not limited to the following: Restricted/Password Areas This form of security is used when specific information can only be accessed by end-users based on a set of accessibility rules. IP Restrictions This form of security is used when only specific locations need to access an application. This form of security is applied from within the web server or a firewall. Network Restrictions (Firewalls) This form of security is used to contain access to an application within a specific sub set of a network. Data Encryption This form of security is used transform personally identifiable information in to something unreadable so that it can be stored for future use. Encrypted Protocols (HTTPS) This form of security is used to prevent others from reading messages being sent between applications over a network.

    Read the article

  • How to resize / enlarge / grow a non-LVM ext4 partition

    - by Mischa
    I have already searched the forums, but couldnt find a good suitable answer: I have an Ubuntu Server 10.04 as KVM Host and a guest system, that also runs 10.04. The host system uses LVM and there are three logical volumes, which are provided to the guest as virtual block devices - one for /, one for /home and one for swap. The guest had been partitioned without LVM. I have already enlarged the logical volume in the host system - the guest successfully sees the bigger virtual disk. However, this virtual disk contains one "good old" partition, which still has the old small size. The output of fdisk -l is me@produktion:/$ LC_ALL=en_US sudo fdisk -l Disk /dev/vda: 32.2 GB, 32212254720 bytes 255 heads, 63 sectors/track, 3916 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000c8ce7 Device Boot Start End Blocks Id System /dev/vda1 * 1 3917 31455232 83 Linux Disk /dev/vdb: 2147 MB, 2147483648 bytes 244 heads, 47 sectors/track, 365 cylinders Units = cylinders of 11468 * 512 = 5871616 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000f2bf7 Device Boot Start End Blocks Id System /dev/vdb1 1 366 2095104 82 Linux swap / Solaris Partition 1 has different physical/logical beginnings (non-Linux?): phys=(0, 32, 33) logical=(0, 43, 28) Partition 1 has different physical/logical endings: phys=(260, 243, 47) logical=(365, 136, 44) Disk /dev/vdc: 225.5 GB, 225485783040 bytes 255 heads, 63 sectors/track, 27413 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00027f25 Device Boot Start End Blocks Id System /dev/vdc1 1 9138 73398272 83 Linux The output of parted print all is Model: Virtio Block Device (virtblk) Disk /dev/vda: 32.2GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 1049kB 32.2GB 32.2GB primary ext4 boot Model: Virtio Block Device (virtblk) Disk /dev/vdb: 2147MB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 1049kB 2146MB 2145MB primary linux-swap(v1) Model: Virtio Block Device (virtblk) Disk /dev/vdc: 225GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 1049kB 75.2GB 75.2GB primary ext4 What I want to achieve is to simply grow or resize the partition /dev/vdc1 so that it uses the whole space provided by the virtual block device /dev/vdc. The problem is, that when I try to do that with parted, it complains: (parted) select /dev/vdc Using /dev/vdc (parted) print Model: Virtio Block Device (virtblk) Disk /dev/vdc: 225GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 1049kB 75.2GB 75.2GB primary ext4 (parted) resize 1 WARNING: you are attempting to use parted to operate on (resize) a file system. parted's file system manipulation code is not as robust as what you'll find in dedicated, file-system-specific packages like e2fsprogs. We recommend you use parted only to manipulate partition tables, whenever possible. Support for performing most operations on most types of file systems will be removed in an upcoming release. Start? [1049kB]? End? [75.2GB]? 224GB Error: File system has an incompatible feature enabled. Compatible features are has_journal, dir_index, filetype, sparse_super and large_file. Use tune2fs or debugfs to remove features. So what can I do? This is a headless production system. What is a safe way to grow this partition? I CAN unmount it, though - so this is not the problem.

    Read the article

  • Open a File Browser From Your Current Command Prompt/Terminal Directory

    - by The Geek
    Ever been doing some work at the command line when you realized… it would be a lot easier if I could just use the mouse for this task? One command later, you’ll have a window open to the same place that you’re at. This same tip works in more than one operating system, so we’ll detail how to do it in every way we know how. Open a File Browser in Windows We’ve actually covered this before when we told you how to open an Explorer window from the command prompt’s current directory, but we’ll briefly review: Just type the follow command into your command prompt: explorer . Note: You could actually just type “start .” instead. And you’ll then see a file browsing window set to the same directory you were previous at. And yes, this screenshot is from Vista, but it works the same in every version of Windows. If that wasn’t good enough, you should really read how you can navigate in the File Open/Save dialogs with just the keyboard—now that’s a Stupid Geek Trick! Open a File Browser in Linux For this exercise, we’re going to assume that you’re using Gnome under a Linux flavor like Ubuntu, because that’s the most common. From your terminal window, just type in the following command: nautilus . And the next thing you know, you’ll have a file browser window open at the current location. You’ll see some type of error message at the prompt, but you can pretty much ignore that. You can also use “gnome-open .” if you want. Open Finder in Mac OS X All the Mac computers in this office are running Linux, so we haven’t had a chance to verify, but you should be able to use the following command on OS X to open Finder in the current terminal location: open . Open Dolphin on Linux KDE4 dolphin . Got any extra tips to help out your fellow readers? How do you do the same thing in KDE3? What about OS X? Leave your savvy advice in the comments, and maybe we’ll update the article. Or not. Either way, it’ll help somebody! Similar Articles Productive Geek Tips Keyboard Ninja: Concatenate Multiple Text Files in WindowsStupid Geek Tricks: Open an Explorer Window from the Command Prompt’s Current DirectoryHow to automate FTP uploads from the Windows Command LineShell Geek: Rename Multiple Files At OnceAdd "Open with gedit" to the right click menu in Ubuntu TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Home Networks – How do they look like & the problems they cause Check Your IMAP Mail Offline In Thunderbird Follow Finder Finds You Twitter Users To Follow Combine MP3 Files Easily QuicklyCode Provides Cheatsheets & Other Programming Stuff Download Free MP3s from Amazon

    Read the article

  • Game Object Factory: Fixing Memory Leaks

    - by Bunkai.Satori
    Dear all, this is going to be tough: I have created a game object factory that generates objects of my wish. However, I get memory leaks which I can not fix. Memory leaks are generated by return new Object(); in the bottom part of the code sample. static BaseObject * CreateObjectFunc() { return new Object(); } How and where to delete the pointers? I wrote bool ReleaseClassType(). Despite the factory works well, ReleaseClassType() does not fix memory leaks. bool ReleaseClassTypes() { unsigned int nRecordCount = vFactories.size(); for (unsigned int nLoop = 0; nLoop < nRecordCount; nLoop++ ) { // if the object exists in the container and is valid, then render it if( vFactories[nLoop] != NULL) delete vFactories[nLoop](); } return true; } Before taking a look at the code below, let me help you in that my CGameObjectFactory creates pointers to functions creating particular object type. The pointers are stored within vFactories vector container. I have chosen this way because I parse an object map file. I have object type IDs (integer values) which I need to translate them into real objects. Because I have over 100 different object data types, I wished to avoid continuously traversing very long Switch() statement. Therefore, to create an object, I call vFactoriesnEnumObjectTypeID via CGameObjectFactory::create() to call stored function that generates desired object. The position of the appropriate function in the vFactories is identical to the nObjectTypeID, so I can use indexing to access the function. So the question remains, how to proceed with garbage collection and avoid reported memory leaks? #ifndef GAMEOBJECTFACTORY_H_UNIPIXELS #define GAMEOBJECTFACTORY_H_UNIPIXELS //#include "MemoryManager.h" #include <vector> template <typename BaseObject> class CGameObjectFactory { public: // cleanup and release registered object data types bool ReleaseClassTypes() { unsigned int nRecordCount = vFactories.size(); for (unsigned int nLoop = 0; nLoop < nRecordCount; nLoop++ ) { // if the object exists in the container and is valid, then render it if( vFactories[nLoop] != NULL) delete vFactories[nLoop](); } return true; } // register new object data type template <typename Object> bool RegisterClassType(unsigned int nObjectIDParam ) { if(vFactories.size() < nObjectIDParam) vFactories.resize(nObjectIDParam); vFactories[nObjectIDParam] = &CreateObjectFunc<Object>; return true; } // create new object by calling the pointer to the appropriate type function BaseObject* create(unsigned int nObjectIDParam) const { return vFactories[nObjectIDParam](); } // resize the vector array containing pointers to function calls bool resize(unsigned int nSizeParam) { vFactories.resize(nSizeParam); return true; } private: //DECLARE_HEAP; template <typename Object> static BaseObject * CreateObjectFunc() { return new Object(); } typedef BaseObject*(*factory)(); std::vector<factory> vFactories; }; //DEFINE_HEAP_T(CGameObjectFactory, "Game Object Factory"); #endif // GAMEOBJECTFACTORY_H_UNIPIXELS

    Read the article

  • Retrofit Certification

    - by Bill Evjen
    Impact of Regulations on Cabin Systems Installation John Courtright, Structural Integrity Engineering There are “heightened” FAA attention to technical issues related to IFE and Wi-Fi Systems Installations The Aging Aircraft Safety Rule – EWIS & Damage Tolerance Analysis The Challenge: Maximize Flight Safety While Minimizing Costs Issue Papers & Testing, Testing, Testing The role of Airworthiness Directives (ADs) on the design of many IFE systems and all antenna systems. Goal is safety AND cost-effective maintenance intervals and inspection techniques The STC Process Briefly Stated Type Certifications (TC) Supplemental Type Certifications (STC) The STC Process Project Specific Certification Plan (PSCP) Managed by FAA Aircraft Certification Office (ACO) Type of Project (Electrical/Mechanical Systems or Structural) Specific Type of Aircraft Being Modified Schedule Design & Installation Location What does the STC Plan (PSCP) Cover? System Description – What does the system do? System qualification – Are the components qualified? Certification requirements – What FARs are applicable? Installation detail – what is being modified? Prototype installation – What is new? Functional hazard Assessment (FHA) – is it safe? EZAP-EWIS Requirements – Any aging aircraft issues? Certification Data – How is compliance achieved? Delegation and FAA involvement – Who is doing the work? Proposed certification schedule – When is the installation? Certification documentation – What the FAA Expects to see Cabin Systems Certification Concerns In addition to meeting the requirements for DO-160, Cabin System Certification needs to address issues related to: Power management: Generally, IFE and Wi-Fi Systems are classified as “Non-Essential Equipment” from a certification viewpoint. Connected to “non-essential” power buses Must be able to shed IFE & Wi-Fi Systems in a smoke/fire event or Other electrical emergency (FAA Policy 00-111-160) FAA is more relaxed with testing wi-fi. It used to be that you had to have 150 seats with laptops running wi-fi, but now it is down to around 50. Aging aircraft concerns – electrical and structural Issue papers addressing technical concerns involving: “Structural Certification Criteria for Large Antenna Installations” Antenna “Vibration/Buffeting Compliance Criteria” DO-160 : Environmental Test Procedures DO 160 – “Environmental Conditions and Test Procedures for Airborne Equipment”, Issued by RTCA Provides guidance to equipment manufacturers as to testing requirements Temperature: –40C to +55C Vibration and Shock Contaminant susceptibility – fluids and dust Electro-magnetic Interference Cabin systems are generally classified as “non-essential” Swissair 111 crashed (in part) due to non-standard wiring practices. EWIS Design Implications Installation design must take EWIS Requirements into account. This generally means: Aircraft surveys are needed to identify proper wire routing Ensure existing wiring diagrams are correct Identify primary/Secondary/Tertiary bus locations Verify proper separation of wire bundles exist Required separation from fuel quantity indicator system (FQIS) to prevent fuel tang ignition Enhanced Zonal Analysis Procedure (EZAP) Performed EZAP was developed by the Aging Transport Systems Rulemaking Advisory Committee (ATSRAC) EZAP is the method for analyzing airplane zones with an emphasis on evaluating wiring systems and the existence of combustibles  in the cabin. Certification Considerations for Wi-Fi Systems Electrical – All existing DO 160 testing required Issue papers required Onboard EMI testing – any interference with aircraft systems when multiple wi-fi users are logged on? Vibration/Buffeting compliance criteria – what is the effect of the antenna on aircraft flight characteristics? Structural certification criteria – what are the stress loads on the aircraft at the antenna location and what is the impact on maintenance inspection criteria for the airline? Damage tolerance analysis required Goal – minimize maintenance inspection intervals

    Read the article

  • RemoveHandler Issues with Custom Events

    - by Jeff Certain
    This is a case of things being more complicated that I thought they should be. Since it took a while to figure this one out, I thought it was worth explaining and putting all of the pieces to the answer in one spot. Let me set the stage. Architecturally, I have the notion of generic producers and consumers. These put items onto, and remove items from, a queue. This provides a generic, thread-safe mechanism to load balance the creation and processing of work items in our application. Part of the IProducer(Of T) interface is: 1: Public Interface IProducer(Of T) 2: Event ItemProduced(ByVal sender As IProducer(Of T), ByVal item As T) 3: Event ProductionComplete(ByVal sender As IProducer(Of T)) 4: End Interface Nothing sinister there, is there? In order to simplify our developers’ lives, I wrapped the queue with some functionality to manage the produces and consumers. Since the developer can specify the number of producers and consumers that are spun up, the queue code manages adding event handlers as the producers and consumers are instantiated. Now, we’ve been having some memory leaks and, in order to eliminate the possibility that this was caused by weak references to event handles, I wanted to remove them. This is where it got dicey. My first attempt looked like this: 1: For Each producer As P In Producers 2: RemoveHandler producer.ItemProduced, AddressOf ItemProducedHandler 3: RemoveHandler producer.ProductionComplete, AddressOf ProductionCompleteHandler 4: producer.Dispose() 5: Next What you can’t see in my posted code are the warnings this caused. The 'AddressOf' expression has no effect in this context because the method argument to 'AddressOf' requires a relaxed conversion to the delegate type of the event. Assign the 'AddressOf' expression to a variable, and use the variable to add or remove the method as the handler.  Now, what on earth does that mean? Well, a quick Bing search uncovered a whole bunch of talk about delegates. The first solution I found just changed all parameters in the event handler to Object. Sorry, but no. I used generics precisely because I wanted type safety, not because I wanted to use Object. More searching. Eventually, I found this forum post, where Jeff Shan revealed a missing piece of the puzzle. The other revelation came from Lian_ZA in this post. However, these two only hinted at the solution. Trying some of what they suggested led to finally getting an invalid cast exception that revealed the existence of ItemProducedEventHandler. Hold on a minute! I didn’t create that delegate. There’s nothing even close to that name in my code… except the ItemProduced event in the interface. Could it be? Naaaaah. Hmmm…. Well, as it turns out, there is a delegate created by the compiler for each event. By explicitly creating a delegate that refers to the method in question, implicitly cast to the generated delegate type, I was able to remove the handlers: 1: For Each producer As P In Producers 2: Dim _itemProducedHandler As IProducer(Of T).ItemProducedEventHandler = AddressOf ItemProducedHandler 3: RemoveHandler producer.ItemProduced, _itemProducedHandler 4:  5: Dim _productionCompleteHandler As IProducer(Of T).ProductionCompleteEventHandler = AddressOf ProductionCompleteHandler 6: RemoveHandler producer.ProductionComplete, _productionCompleteHandler 7: producer.Dispose() 8: Next That’s “all” it took to finally be able to remove the event handlers and maintain type-safe code. Hopefully, this will save you the same challenges I had in trying to figure out how to fix this issue!

    Read the article

< Previous Page | 314 315 316 317 318 319 320 321 322 323 324 325  | Next Page >