Search Results

Search found 886 results on 36 pages for 'interop domino'.

Page 32/36 | < Previous Page | 28 29 30 31 32 33 34 35 36  | Next Page >

  • What permission(s) does an application pool identity required to manage other application pools?

    - by Mr Shoubs
    I have a web site (used to manage various parts of our software) that needs the permissions required to start/stop other application pools. I've created a user and set the app pool identity to custom, however the web app still can't start/stop the app pools. I get the following Error: System.UnauthorizedAccessException: Filename: redirection.config Error: Cannot read configuration file due to insufficient permissions at Microsoft.Web.Administration.Interop.AppHostWritableAdminManager.GetAdminSection(String bstrSectionName, String bstrSectionPath) at Microsoft.Web.Administration.Configuration.GetSectionInternal(ConfigurationSection section, String sectionPath, String locationPath) at Microsoft.Web.Administration.ServerManager.get_ApplicationPoolsSection() at Microsoft.Web.Administration.ServerManager.get_ApplicationPools() Discussion here suggests setting the application pool to local system or administrator, this does work, but I don't want to do this for security reasons (external support will need access this site). I did give the user higher permissions (as suggested here), starting by making it part of the local administrators group, but initially this didn't work, and giving the user read/write/mod permission on C:\Windows\System32\inetsrv\config also didn't work. I must have done something wrong as local administrator now works, however this still isn't what I want. So can anyone suggest the permissions I need to add to this user, and how can I apply them? An answer my problem (but different question) is here, but to clarify, I think I need to give an individual user "IIS Runtime Operation Permissions", does anyone know how to do this, if indeed this is the permissions I require?

    Read the article

  • "Exception has been thrown by the target of an invocation" Running Tests - VS2008 SP1

    - by omatrot
    I'm using Visual Studio 2008 Team Suite and I'm unable to run tests and display the Test/Windows/Test Result Window. The result is a dialog box with the following content : "Exception has been thrown by the target of an invocation". Team Explorer has been installed after Visual Studio 2008 SP1. So I have re-apllied the service pack. Searching the web I found that this error is pretty common but unfortunately, the proposed solutions does not work for me. The problem was never analysed so I decided to give it a try : I reproduced the problem on a computer, attached the process with windbg and start with the basic investigations. Following are the first results : 0:000>!dumpstack OS Thread Id: 0xdb0 (0) Current frame: USER32!NtUserWaitMessage+0x15 ChildEBP RetAddr Caller,Callee 003fec94 75a32674 USER32!DialogBox2+0x222, calling USER32!NtUserWaitMessage 003fecd0 75a3288a USER32!InternalDialogBox+0xe5, calling USER32!DialogBox2 003fecfc 75a6f8d0 USER32!SoftModalMessageBox+0x757, calling USER32!InternalDialogBox 003fed3c 6eb61996 mscorwks!Thread::ReverseLeaveRuntime+0x95, calling mscorwks!_EH_epilog3 003fedb0 75a6fbac USER32!MessageBoxWorker+0x269, calling USER32!SoftModalMessageBox 003fede0 6ea559c3 mscorwks!SetupThreadNoThrow+0x19a, calling mscorwks!_EH_epilog3_catch_GS 003fee24 6eb61d8a mscorwks!HasIllegalReentrancy+0xac, calling mscorwks!_EH_epilog3 003fee30 6ea89796 mscorwks!SimpleComCallWrapper::Release+0x2e, calling mscorwks!CompareExchangeMP 003fee38 6ea0da05 mscorwks!CLRException::HandlerState::CleanupTry+0x16, calling mscorwks!GetCurrentSEHRecord 003fee44 6ea0c9c0 mscorwks!Thread::EnablePreemptiveGC+0xf, calling mscorwks!Thread::CatchAtSafePoint 003fee4c 6ea8a241 mscorwks!Unknown_Release_Internal+0x24d, calling mscorwks!GCHolder<1,0,0>::Pop 003fee50 6ea0c86c mscorwks!_EH_epilog3_catch_GS+0xa, calling mscorwks!__security_check_cookie 003fee54 6ea8a24c mscorwks!Unknown_Release_Internal+0x258, calling mscorwks!_EH_epilog3_catch_GS 003fee7c 75a16941 USER32!UserCallWinProcCheckWow+0x13d, calling ntdll!RtlDeactivateActivationContextUnsafeFast 003feed8 7082119e msenv!ATL::CComCritSecLock<ATL::CComCriticalSection>::Lock+0xd, calling ntdll!RtlEnterCriticalSection 003fef08 75a6fe5b USER32!MessageBoxIndirectW+0x2e, calling USER32!MessageBoxWorker 003fef7c 70a1e367 msenv!MessageBoxPVoidW+0xda 003fefd4 70a1db60 msenv!VBDialogCover2+0x11b 003ff01c 70a1e4c0 msenv!VBMessageBox2W+0xf0, calling msenv!VBDialogCover2 003ff044 7087246b msenv!main_GetAppNameW+0xa, calling msenv!GetAppNameInternal 003ff04c 70a1e4f2 msenv!VBMessageBox3W+0x1c, calling msenv!VBMessageBox2W 003ff064 70a1d6d7 msenv!_IdMsgShow+0x362, calling msenv!VBMessageBox3W 003ff0cc 70951841 msenv!TaskDialogCallback+0x7e0, calling msenv!_IdMsgShow 003ff118 6eb20da4 mscorwks!Unknown_QueryInterface+0x230, calling mscorwks!_EH_epilog3_catch_GS 003ff14c 6eb20c43 mscorwks!Unknown_QueryInterface_Internal+0x3d8, calling mscorwks!_EH_epilog3_catch_GS 003ff168 02006ec4 02006ec4, calling 0247a1e8 003ff16c 6ea0c86c mscorwks!_EH_epilog3_catch_GS+0xa, calling mscorwks!__security_check_cookie 003ff198 6eb20562 mscorwks!COMToCLRWorker+0xb34, calling mscorwks!_EH_epilog3_catch_GS 003ff19c 0247a235 0247a235, calling mscorwks!COMToCLRWorker 003ff1c4 7083249f msenv!CVSCommandTarget::ExecCmd+0x937 003ff1e4 7086d5c8 msenv!VsReportErrorInfo+0x11, calling msenv!TaskDialogCallback+0xd8 003ff1f8 7093e65b msenv!CVSCommandTarget::ExecCmd+0x945, calling msenv!VsReportErrorInfo 003ff25c 7081f53a msenv!ATL::CComPtr<IVsLanguageInfo>::~CComPtr<IVsLanguageInfo>+0x24, calling msenv!_EH_epilog3 003ff260 70b18d72 msenv!LogCommand+0x4c, calling msenv!ATL::CComPtr<IVsCodePageSelection>::~CComPtr<IVsCodePageSelection> 003ff264 70b18d77 msenv!LogCommand+0x51, calling msenv!_EH_epilog3 003ff280 70a4fd0e msenv!CMsoButtonUser::FClick+0x1d1, calling msenv!CVSCommandTarget::ExecCmd 003ff2f4 70823a87 msenv!CTLSITE::QueryInterface+0x16 003ff31c 70cb7d4d msenv!TBCB::FNotifyFocus+0x204 003ff35c 70ce5fda msenv!TB::NotifyControl+0x101 003ff3bc 709910f6 msenv!TB::FRequestFocus+0x4ed, calling msenv!TB::NotifyControl 003ff414 708254ba msenv!CMsoButtonUser::FEnabled+0x3d, calling msenv!GetQueryStatusFlags 003ff428 7086222a msenv!TBC::FAutoEnabled+0x24 003ff43c 7098e1eb msenv!TB::LProcessInputMsg+0xdb4 003ff458 6bec1c49 (MethodDesc 0x6bcd7f54 +0x89 System.Windows.Forms.Form.DefWndProc(System.Windows.Forms.Message ByRef)), calling 6be3b738 003ff50c 70823ab0 msenv!FPtbFromSite+0x16 003ff520 70991c43 msenv!TB::PtbParent+0x25, calling msenv!FPtbFromSite 003ff52c 708dda49 msenv!TBWndProc+0x2da 003ff588 0203d770 0203d770, calling 0247a1e8 003ff598 70822a70 msenv!CPaneFrame::Release+0x118, calling msenv!_EH_epilog3 003ff5b0 75a16238 USER32!InternalCallWinProc+0x23 003ff5dc 75a168ea USER32!UserCallWinProcCheckWow+0x109, calling USER32!InternalCallWinProc 003ff620 75a16899 USER32!UserCallWinProcCheckWow+0x6a, calling ntdll!RtlActivateActivationContextUnsafeFast 003ff654 75a17d31 USER32!DispatchMessageWorker+0x3bc, calling USER32!UserCallWinProcCheckWow 003ff688 70847f2b msenv!CMsoComponent::FPreTranslateMessage+0x72, calling msenv!MainFTranslateMessage 003ff6b4 75a17dfa USER32!DispatchMessageW+0xf, calling USER32!DispatchMessageWorker 003ff6c4 70831553 msenv!EnvironmentMsgLoop+0x1ea, calling USER32!DispatchMessageW 003ff6f8 708eb9bd msenv!CMsoCMHandler::FPushMessageLoop+0x86, calling msenv!EnvironmentMsgLoop 003ff724 708eb94d msenv!SCM::FPushMessageLoop+0xb7 003ff74c 708eb8e9 msenv!SCM_MsoCompMgr::FPushMessageLoop+0x28, calling msenv!SCM::FPushMessageLoop 003ff768 708eb8b8 msenv!CMsoComponent::PushMsgLoop+0x28 003ff788 708ebe4e msenv!VStudioMainLogged+0x482, calling msenv!CMsoComponent::PushMsgLoop 003ff7ac 70882afe msenv!CVsActivityLogSingleton::Instance+0xdf, calling msenv!_EH_epilog3 003ff7d8 70882afe msenv!CVsActivityLogSingleton::Instance+0xdf, calling msenv!_EH_epilog3 003ff7dc 707e4e31 msenv!VActivityLogStartupEntries+0x42 003ff7f4 7081f63b msenv!ATL::CComPtr<IClassFactory>::~CComPtr<IClassFactory>+0x24, calling msenv!_EH_epilog3 003ff7f8 708b250f msenv!ATL::CComQIPtr<IUnknown,&IID_IUnknown>::~CComQIPtr<IUnknown,&IID_IUnknown>+0x1d, calling msenv!_EH_epilog3 003ff820 708e7561 msenv!VStudioMain+0xc1, calling msenv!VStudioMainLogged 003ff84c 2f32aabc devenv!util_CallVsMain+0xff 003ff878 2f3278f2 devenv!CDevEnvAppId::Run+0x11fd, calling devenv!util_CallVsMain 003ff97c 77533b23 ntdll!RtlpAllocateHeap+0xe73, calling ntdll!_SEH_epilog4 003ff9f0 77536cd7 ntdll!RtlpLowFragHeapAllocFromContext+0x882, calling ntdll!RtlpSubSegmentInitialize 003ffa10 7753609f ntdll!RtlNtStatusToDosError+0x3b, calling ntdll!RtlNtStatusToDosErrorNoTeb 003ffa14 775360a4 ntdll!RtlNtStatusToDosError+0x40, calling ntdll!_SEH_epilog4 003ffa40 775360a4 ntdll!RtlNtStatusToDosError+0x40, calling ntdll!_SEH_epilog4 003ffa44 75bd2736 kernel32!LocalBaseRegOpenKey+0x159, calling ntdll!RtlNtStatusToDosError 003ffa48 75bd2762 kernel32!LocalBaseRegOpenKey+0x22a, calling kernel32!_SEH_epilog4 003ffac4 75bd2762 kernel32!LocalBaseRegOpenKey+0x22a, calling kernel32!_SEH_epilog4 003ffac8 75bd28c9 kernel32!RegOpenKeyExInternalW+0x130, calling kernel32!LocalBaseRegOpenKey 003ffad8 75bd28de kernel32!RegOpenKeyExInternalW+0x211 003ffae0 75bd28e5 kernel32!RegOpenKeyExInternalW+0x21d, calling kernel32!_SEH_epilog4 003ffb04 6f282e2b MSVCR90!_unlock+0x15, calling ntdll!RtlLeaveCriticalSection 003ffb14 75bd2642 kernel32!BaseRegCloseKeyInternal+0x41, calling ntdll!NtClose 003ffb28 75bd25d0 kernel32!RegCloseKey+0xd4, calling kernel32!_SEH_epilog4 003ffb5c 75bd25d0 kernel32!RegCloseKey+0xd4, calling kernel32!_SEH_epilog4 003ffb60 2f321ea4 devenv!DwInitSyncObjects+0x340 003ffb90 2f327bf4 devenv!WinMain+0x74, calling devenv!CDevEnvAppId::Run 003ffbac 2f327c68 devenv!License::GetPID+0x258, calling devenv!WinMain 003ffc3c 75bd3677 kernel32!BaseThreadInitThunk+0xe 003ffc48 77539d72 ntdll!__RtlUserThreadStart+0x70 003ffc88 77539d45 ntdll!_RtlUserThreadStart+0x1b, calling ntdll!__RtlUserThreadStart 0:000> !pe -nested Exception object: 050aae9c Exception type: System.Reflection.TargetInvocationException Message: Exception has been thrown by the target of an invocation. InnerException: System.NullReferenceException, use !PrintException 050aac64 to see more StackTrace (generated): SP IP Function 003FEC2C 6D2700F7 mscorlib_ni!System.RuntimeType.CreateInstanceSlow(Boolean, Boolean)+0x57 003FEC5C 6D270067 mscorlib_ni!System.RuntimeType.CreateInstanceImpl(Boolean, Boolean, Boolean)+0xe7 003FEC94 6D270264 mscorlib_ni!System.Activator.CreateInstance(System.Type, Boolean)+0x44 003FECA4 6AD02DAF Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.CreateToolWindow(System.Type, Int32, Microsoft.VisualStudio.Shell.ProvideToolWindowAttribute)+0x67 003FED30 6AD0311B Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.CreateToolWindow(System.Type, Int32)+0xb7 003FED58 6AD02D12 Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.FindToolWindow(System.Type, Int32, Boolean, Microsoft.VisualStudio.Shell.ProvideToolWindowAttribute)+0x7a 003FED88 6AD02D39 Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.FindToolWindow(System.Type, Int32, Boolean)+0x11 003FED94 02585E30 Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.InitToolWindowVariable[[System.__Canon, mscorlib]](System.__Canon ByRef, System.String, Boolean)+0x58 003FEDD0 02585DBE Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.InitToolWindowVariable[[System.__Canon, mscorlib]](System.__Canon ByRef, System.String)+0x36 003FEDE4 02585D32 Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.ShowToolWindow[[System.__Canon, mscorlib]](System.__Canon ByRef, System.String, Boolean)+0x3a 003FEE00 02585AB4 Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.OpenTestResultsToolWindow()+0x2c 003FEE10 02585A6E Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.OnMenuViewTestResults(System.Object, System.EventArgs)+0x6 003FEE18 6CD4F993 System_ni!System.ComponentModel.Design.MenuCommand.Invoke()+0x43 003FEE40 6CD4F9D4 System_ni!System.ComponentModel.Design.MenuCommand.Invoke(System.Object)+0x8 003FEE48 6AD000FA Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.OleMenuCommandService.Microsoft.VisualStudio.OLE.Interop.IOleCommandTarget.Exec(System.Guid ByRef, UInt32, UInt32, IntPtr, IntPtr)+0x11a 003FEEA0 6AD03FB8 Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.Microsoft.VisualStudio.OLE.Interop.IOleCommandTarget.Exec(System.Guid ByRef, UInt32, UInt32, IntPtr, IntPtr)+0x44 StackTraceString: <none> HResult: 80131604 0:000> !PrintException 050aac64 Exception object: 050aac64 Exception type: System.NullReferenceException Message: Object reference not set to an instance of an object. InnerException: <none> StackTrace (generated): SP IP Function 003FE660 078E60BE Microsoft_VisualStudio_TeamSystem_Integration!Microsoft.VisualStudio.TeamSystem.Integration.TcmResultsPublishManager..ctor(Microsoft.VisualStudio.TeamSystem.Integration.ResultsPublishManager)+0xc6 003FE674 078E5C91 Microsoft_VisualStudio_TeamSystem_Integration!Microsoft.VisualStudio.TeamSystem.Integration.ResultsPublishManager..ctor(Microsoft.VisualStudio.TeamSystem.Integration.TeamFoundationHostHelper)+0x59 003FE684 078E2FA0 Microsoft_VisualStudio_TeamSystem_Integration!Microsoft.VisualStudio.TeamSystem.Integration.VsetServerHelper..ctor(System.IServiceProvider)+0x50 003FE6A4 078E2E90 Microsoft_VisualStudio_TeamSystem_Common!Microsoft.VisualStudio.TeamSystem.Integration.Client.VsetHelper.InitializeThrow(System.IServiceProvider)+0x20 003FE6B8 078E2E2A Microsoft_VisualStudio_TeamSystem_Common!Microsoft.VisualStudio.TeamSystem.Integration.Client.VsetHelper.InitializeHelper(System.IServiceProvider)+0x22 003FE6E0 078E2DEC Microsoft_VisualStudio_TeamSystem_Common!Microsoft.VisualStudio.TeamSystem.Integration.Client.VsetHelper.CreateVsetHelper(System.IServiceProvider)+0x1c 003FE6F0 078E2DAC Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.get_VsetHelper()+0x14 003FE6F8 02586BBE Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.ResultsToolWindow..ctor()+0x9f6 003FE798 02585F8A Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.ResultToolWindowHost..ctor()+0x1a StackTraceString: <none> HResult: 80004003 In order to be able to continue the analysis, we need to get the parameters to see what is going on. I also tried to run devenv.exe with the /log switch. No error in the log after reproducing the problem. Finally, If Team Explorer is removed from the system, the problem goes away. Any help appreciated. TIA. Olivier.

    Read the article

  • Binding Image.Source to String in WPF ?

    - by Mohammad
    I have below XAML code : <Window x:Class="WpfApplication1.Window1" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" DataContext="{Binding RelativeSource={RelativeSource Self}}" WindowStartupLocation="CenterScreen" Title="Window1" Height="300" Width="300"> <Grid> <Image x:Name="TestImage" Source="{Binding Path=ImageSource}" /> </Grid> </Window> Also, there is a method that makes an Image from a Base64 string : Image Base64StringToImage(string base64ImageString) { try { byte[] b; b = Convert.FromBase64String(base64ImageString); MemoryStream ms = new System.IO.MemoryStream(b); System.Drawing.Image img = System.Drawing.Image.FromStream(ms); ////////////////////////////////////////////// //convert System.Drawing.Image to WPF image System.Drawing.Bitmap bmp = new System.Drawing.Bitmap(img); IntPtr hBitmap = bmp.GetHbitmap(); System.Windows.Media.ImageSource imageSource = System.Windows.Interop.Imaging.CreateBitmapSourceFromHBitmap(hBitmap, IntPtr.Zero, Int32Rect.Empty, BitmapSizeOptions.FromEmptyOptions()); Image wpfImage = new Image(); wpfImage.Source = imageSource; wpfImage.Width = wpfImage.Height = 16; ////////////////////////////////////////////// return wpfImage; } catch { Image img1 = new Image(); img1.Source = new BitmapImage(new Uri(@"/passwordManager;component/images/TreeView/empty-bookmark.png", UriKind.Relative)); img1.Width = img1.Height = 16; return img1; } } Now, I'm gonna bind TestImage to the output of Base64StringToImage method. I've used the following way : public string ImageSource { get; set; } ImageSource = Base64StringToImage("iVBORw0KGgoAAAANSUhEUgAAABAAAAAQCAMAAAAoLQ9TAAAABGdBTUEAAK/INwWK6QAAABl0RVh0U29mdHdhcmUAQWRvYmUgSW1hZ2VSZWFkeXHJZTwAAABjUExURXK45////6fT8PX6/bTZ8onE643F7Pf7/pDH7PP5/dns+b7e9MPh9Xq86NHo947G7Hm76NTp+PL4/bHY8ojD67rc85bK7b3e9MTh9dLo97vd8/D3/Hy96Xe76Nfr+H+/6f///1bvXooAAAAhdFJOU///////////////////////////////////////////AJ/B0CEAAACHSURBVHjaXI/ZFoMgEEMzLCqg1q37Yv//KxvAlh7zMuQeyAS8d8I2z8PT/AMDShWQfCYJHL0FmlcXSQTGi7NNLSMwR2BQaXE1IfAguPFx5UQmeqwEHSfviz7w0BIMyU86khBDZ8DLfWHOGPJahe66MKe/fIupXKst1VXxW/VgT/3utz99BBgA4P0So6hyl+QAAAAASUVORK5CYIII").Source.ToString(); but nothing happen. How can I fix it ? BTW, I'm dead sure that the base64 string is correct

    Read the article

  • Embed PowerPoint Viewer in C# Win Form

    - by Soppus
    Is it possible to Embed a PowerPoint Viewer into a C# Windows Form? I am currently use the following code: objApp = new PowerPoint.Application(); //objApp.Visible = MsoTriState.msoTrue; objPresSet = objApp.Presentations; objPres = objPresSet.Open(ppsAction.FileInfo.FullName, MsoTriState.msoTrue, MsoTriState.msoTrue, MsoTriState.msoFalse); objSlides = objPres.Slides; //Run the Slide show objSSS = objPres.SlideShowSettings; objSSS.ShowType = Microsoft.Office.Interop.PowerPoint.PpSlideShowType.ppShowTypeSpeaker; objSSS.LoopUntilStopped = MsoTriState.msoTrue; objSSS.Run(); WindowWrapper handleWrapper = new WindowWrapper(objPres.SlideShowWindow.HWND); SetParent(handleWrapper.Handle, this.ApplicationPanel.Handle); this.ApplicationPanel.Visible = true; objPres.SlideShowWindow.Height = ApplicationPanel.Height; objPres.SlideShowWindow.Width = ApplicationPanel.Width; objPres.SlideShowWindow.Top = 0; objPres.SlideShowWindow.Left = 0; It shows the viewer on the form but the placement and sizing is wrong. How would one size and place it correctly. Another option: I have encountered the Aximp.exe application meant to be used for showing ActiveX controls on the Win Forms in C#. How would I use this with the PPT Viewer?

    Read the article

  • Can't step into stored procedure on remote SQL Server 2008

    - by abatishchev
    I have a domain installed on virtual Windows Server 2008 x64. SQL Server 2008 Express x64 is running in Windows Server 2008 x64 and client on Windows 7 RTM x86. Both are into the domain. I'm starting both Visual Studio 2008 and SQL Server Management Studio 2008 under domain admin user. This account is a member of group sysadmin on SQL Server. Server has firewall exceptions for both TCP and UDP on ports 135-139 and 1433-1434. Visual Studio 2008 Remote debugger services is started on server and Domain Admins group is allowed to debug, When I'm starting debugging of a query in SMS I'm getting this error: Failed to start debugger Error HRESULT E_FAIL has been returned from a call to a COM component. (mscorlib) Program Location: at System.Runtime.InteropServices.Marshal.ThrowExceptionForHRInternal(Int32 errorCode, IntPtr errorInfo) at Microsoft.SqlServer.Management.UI.VSIntegration.DebugSession.DebugCallbacks.OnSqlInitializeDebuggingEvent(ISqlInitializeDebuggingEvent sqlInitializeDebuggingEvent) at Microsoft.SqlServer.Management.UI.VSIntegration.DebugSession.DebugCallbacks.Microsoft.VisualStudio.Debugger.Interop.IDebugEventCallback2.Event(IDebugEngine2 debugEngine, IDebugProcess2 debugProcess, IDebugProgram2 debugProgram, IDebugThread2 debugThread, IDebugEvent2 debugEvent, Guid& riidEvent, UInt32 attribute) and Unable to access the SQL Server debugging interface. The Visual Studio debugger cannot connect to the remote computer. A firewall may be preventing communication via DCOM to the remote computer. Please see Help for assistance. and Unable to start program MSSSQL://server.mydomain.local/master/sys/=0 And when stepping-in into a stored procedure using VS I'm getting the first one and this: Exception from HRESULT: 0x89710016 What have I do?

    Read the article

  • VSTO Development - Key Improvements In VS2010 / .NET 4.0?

    - by dferraro
    Hi all, I am trying to make a case to my bosses on why we should use VS2010 for an upcoming Excel Workbook VSTO application. I haven't used VSTO before but have used VBA. With 2010 just around the corner, I wanted to read about the improvements made to see if it was worth using 2010 to develop this application. So far I have read 2 major improvements are ease of deployments and also debugging / com interop improvements ... I was just wondering if there was anything else I wasn't aware of, or if anyone here is actually developing in VSTO and has used 2010 and both 2008 and could help make a case / arm me with information. The main concern of my bosses is deploying .NET 4.0 runtime on the Citrix servers here... however it seems that with 3.5, we would have to deploy the VSTO runtime and PIA's, etc... So really wouldn't deployments be easier with 2010 because installing just the 4.0 runtime is better than having to install the 'VSTO Runtime' as well as PIA's, etc? Or is there something I'm missing here? Anyone here deploy VSTO app in an enterprise and can speak to this? Also - I'm trying to also fight to use C# over VB.NET for this app. Does anyone know any key reasons why (except for my bias on preference of syntax) it would be better to use C# over VB for this? Any key features lacking in VB VSTO development? I've read about the VSTO Power Tools, and one of them describes LINQ enalbment of the Excel Object Model classes - however it says 'a set of C# classes'... Does anyone know if they literally mean C# - so this would not work with VB.NET, or do they just mean the code is written in C#? Anyone ever used these power tools with VB? I am going to download & play with it now, but any help again is greatly appreciated Thanks very much for any information.

    Read the article

  • Retrieving the COM class factory for component error while generating word document

    - by TheDPQ
    Hello, I am trying to edit a word document from VB.NET using for the most part this code: How to automate Word from Visual Basic .NET to create a new document http://support.microsoft.com/kb/316383 It works fine on my machine but when i publish to the server i get the following error. Retrieving the COM class factory for component with CLSID {000209FF-0000-0000-C000-000000000046} failed due to the following error: 80070005. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.UnauthorizedAccessException: Retrieving the COM class factory for component with CLSID {000209FF-0000-0000-C000-000000000046} failed due to the following error: 80070005. The actual error happens when i try to just create a word application object Dim oWord As New Word.Application Using Visual Studio 2008 and VB.NET 3.5. I made a reference to the "Microsoft Word 10.0 Object Library" and i see Interop.Word.dll file in the bin directory. Using MS Office 2003 on development machine and Windows Server 2003 Still fairly new to .NET and don't have much knowledge about window server, but "UnauthorizedAccessException" sounds like a permission issue. I'm wondering if someone could point me in the right direction on what i might need to do to give my little application access to use word. Thank you so much for your time.

    Read the article

  • How to create basic Adobe Illustrator files programatically?

    - by Jonas Follesø
    I need to create a really basic Adobe Illustrator file on the clipboard that I can paste in Adobe Illustrator or Expression Design. I'm looking for code samples on how to programaticaly generate Adobe Illustrator Files, preferably from C# or some other .NET language (but at the moment any language goes). I have found the Adobe Illustrator 3 File Format documentation online but it's allot to digest for this simple scenario. I don't want to depend on the actual Adobe Illustrator program (COM interop for instance) to generate my documents. Must be pure code. The code is for an Expression Studio addin, and I need to be able to create something on the clipboard I can paste into Expression Design. After looking at the formats Expression Design puts on the clipboard when copying a basic shape I've concluded that ADOBE AI3 i the best one to use (the others are either rendered images, or cfXaml that you cannot paste INTO Design). So based on this I can't use SWG which would probably been easier. Another idea might be to use a PDF component as the AI and PDF format is supposed to be compatible? I'm also finding some references to a format called "Adobe Illustrator Clipboard Format" (AICB), but can't find allot of documentation about it.

    Read the article

  • HTML to RTF Converter for .NET

    - by nickyt
    I've already seen lots of posts on the site for RTF to HTML and some other posts talking about some HTML to RTF converters, but I'm really trying to get a full breakdown of what is considered the most widely used commercial product, open source product or if people recommend going home grown. Apologies if you consider this a duplicate question, but I'm trying to create a product matrix to see what is the most viable for our application. I also think this would be helpful for others. The converter would be used in an ASP.NET 2.0 application (we're upgrading to 3.5 shortly but still sticking with WebForms) using SQLServer 2005 (soon 2008) as the DB. From reading a few posts, SautinSoft appears to be popular as a commercial component. Are there other commercial components that you'd recommend for converting HTML to RTF? Price does matter, but even if it's a little on the expensive side, please list it. For open source, I read that OpenOffice.org can be run as a service so that it can convert files. However, this appears to be only Java based. I imagine, I'd need some kind of interop to use this? What .NET open source components, if any, are out there for converting HTML to RTF? For home grown, is an XSLT the way to go with XHTML? If so, what component do you recommend for generating XHTML? Otherwise, what other home grown avenuses do you recommend. Also, please note that I currently don't care so much about RTF to HTML. If a commercial component offers this and the price is still the same, fine, otherwise please don't mention it.

    Read the article

  • When programatically creating a new IIS web site, how can I add it to an existing application pool?

    - by Ian Robinson
    I have successfully automated the process of creating a new IIS website, however the code I've written doesn't care about application pools, it just gets added to DefaultAppPool. However I'd like to add this newly created site to an existing application pool. Here is the code I'm using to create the new website. var w3Svc = new DirectoryEntry(string.Format("IIS://{0}/w3svc", webserver)); var newsite = new object[] { serverComment, new object[] { serverBindings }, homeDirectory }; var websiteId = w3Svc.Invoke("CreateNewSite", newsite); site.Invoke("Start", null); site.CommitChanges(); <update Although this is not directly related to the question, here are some sample values being used above. This might help someone understand exactly what the code above is doing more easily. webServer: "localhost" serverComment: "testing.dev" serverBindings: ":80:testing.dev" homeDirectory: "c:\inetpub\wwwroot\testing\" </update If I know the name of the application pool that I'd like this web site to be in, how can I find it and add this site to it? <update 2 I've added the following based on Mark's answer below. var appPool = new DirectoryEntry(string.Format("IIS://{0}/w3svc/AppPools/{1}", webServer, appPoolName)); site.Properties["AppPoolId"].Value = appPool; I seem to have moved passed the "RPC" error message I was initially receiving. Now this is the error message I'm receiving: Error: System.Runtime.InteropServices.COMException (0x8000500C): Exception from HRESULT: 0x8000500C at System.DirectoryServices.Interop.UnsafeNativeMethods.IAds.PutEx(Int32 lnControlCode, String bstrName, Object vProp) at System.DirectoryServices.PropertyValueCollection.set_Value(Object value) at ProvisionIISWebsite.Query.CreateWebsite(String webServer, String serverComment, String serverBindings, String homeDirectory, String appPoolName) in C:\Users\irobinson\My Projects\ProvisionIISWebsite\Query.cs:line 104 at ProvisionIISWebsite.Query.Handle_GetData(EngineBase& caller, Boolean isSubQuery, String query, String filterField, String filterText, Debugger& debugWriter, Boolean isRendered, Int32 timeout, String customConnection) in C:\Users\irobinson\My Projects\ProvisionIISWebsite\Query.cs:line 36 </update 2

    Read the article

  • Issue with VS 2008 designer and usercontrol.

    - by Ram
    Hello, I have created a custom data grid control. I dragged it on windows form and set its properties like column and all & ran the project. It built successfully and I am able to view the grid control on the form. Now if i try to view that form in designer, I am getting following error.. Object reference not set to an instance of an object. Instances of this error (1) 1. Hide Call Stack at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.GetMemberTargetObject(XmlElementData xmlElementData, String& member) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.CreateAssignStatement(XmlElementData xmlElement) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.XmlElementData.get_CodeDomElement() at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.EndElement(String prefix, String name, String urn) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.Parse(XmlReader reader) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.ParseXml(String xmlStream, CodeStatementCollection statementCollection, String fileName, String methodName) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomParser.OnMethodPopulateStatements(Object sender, EventArgs e) at System.CodeDom.CodeMemberMethod.get_Statements() at System.ComponentModel.Design.Serialization.TypeCodeDomSerializer.Deserialize(IDesignerSerializationManager manager, CodeTypeDeclaration declaration) at System.ComponentModel.Design.Serialization.CodeDomDesignerLoader.PerformLoad(IDesignerSerializationManager manager) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomDesignerLoader.PerformLoad(IDesignerSerializationManager serializationManager) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomDesignerLoader.DeferredLoadHandler.Microsoft.VisualStudio.TextManager.Interop.IVsTextBufferDataEvents.OnLoadCompleted(Int32 fReload) If I ignore the exception, form appears blank with no sign of grid control on it. However I can see the code for the grid in the designer file. Any pointer on this would be a great help.

    Read the article

  • upgrading .NET application from MapPoint 2004 to 2009...

    - by Joshua
    I am in the process of upgrading a Visual Studio 2005 .NET (C#) application from it's integration with MapPoint 2004 to supporting MapPoint 2009. After a bit of searching and fiddling, I've generated new DLLs using "tldimp" and "aximp" and now have Interop.MapPoint.dll and AxInterop.MapPoint.dll and the namespaces seem to line up to the previous ones, so all the object definitions are available. However, I have lots of errors telling me that various properties do not exist, even though I go into the Object Browser, and they do seem to exist. Here is an example (there are dozens of similar errors)... axMappointControl1.ActiveMap.Altitude = 1000; That object initializes fine, as a MapPoint.Map object, which when I browse to in the Object Browser, I go to MapPoint and Map and under Map there are no properties but when I look deeper there is _Map80 and _Map90 and EACH of these has an Altitude property. Under Map it also lists "Base Types", which has _Map in it which also has all the referenced properties! Yet, I am getting the error: "MapPoint.Map' does not contain a definition for 'Altitude' Pretty much all the properties of both MapPoint.Map and MapPoint.Toolbars are doing this. Any ideas? Thank you! Joshua

    Read the article

  • error: unable to open database file, SQLiteException was unhandled

    - by rose
    My project has a reference to SQLite.Interop.066.dll and even after putting in the correct path to the SQLite database, the application is still unable to find it. A SQLiteException was unhandled is returned. SQLiteConnection conn = new SQLiteConnection(); //SQLiteDataAdapter da; SQLiteCommandBuilder cb; DataTable dt=new DataTable(); int row = 0; conn.ConnectionString = "Data Source=C:\\database\\info"; conn.Open(); DataRow dr = dt.NewRow(); dr["name"] = txtName.Text; dr["address"] = txtAddress.Text; dr["phone"] = txtPhone.Text; dr["position"] = txtPosition.Text; dt.Rows.Add(dr); da.Update(dt); row = dt.Rows.Count - 1; txtName.Text = dt.Rows[row]["name"].ToString(); txtAddress.Text = dt.Rows[row]["address"].ToString(); txtPhone.Text = dt.Rows[row]["phone"].ToString(); txtPosition.Text = dt.Rows[row]["position"].ToString(); da.Fill(dt); cb = new SQLiteCommandBuilder(da); conn.Dispose(); conn.Close(); The exception occur at line: conn.Open(); sorry for the mistake title error before...

    Read the article

  • Distinguishing between .NET exception types

    - by Swingline Rage
    For the love of all things holy, how do you distinguish between different "exception flavors" within the predefined .NET exception classes? For example, a piece of code might throw an XmlException under the following conditions: The root element of the document is NULL Invalid chars are in the document The document is too long All of these are thrown as XmlException objects and all of the internal "tell me more about this exception" fields (such as Exception.HResult, Exception.Data, etc.) are usually empty or null. That leaves Exception.Message as the only thing that allows you to distinguish among these exception types, and you can't really depend on it because, you guessed it, the Exception.Message string is glocabilized, and can change when the culture changes. At least that's my read on the documentation. Exception.HResult and Exception.Data are widely ignored across the .NET libraries. They are the red-headed stepchildren of the world's .NET error-handling code. And even assuming they weren't, the HRESULT type is still the worst, downright nastiest error code in the history of error codes. Why we are still looking at HRESULTs in 2010 is beyond me. I mean if you're doing Interop or P/Invoke that's one thing but... HRESULTs have no place in System.Exception. HRESULTs are a wart on the proboscis of System.Exception. But seriously, it means I have to set up a lot of detailed specific error-handling code in order to figure out the same information that should have been passed as part of the exception data. Exceptions are useless if they force you to work like this. What am I doing wrong?

    Read the article

  • Handling Digital ID/Signature in Outlook Add-in

    - by CoSteve
    I have a C# Outlook Add-In application (VS2005 and 2003 Outlook) that reads incoming emails and strips out the attachments and the email text body for future processing. Occasionally I'll get an email that contains a digital signature. The application will fail when I try to access the mailitem.body property, throwing the following exception: System.Runtime.InteropServices.COMException (0xAB404001): The operation failed. at Microsoft.Office.Interop.Outlook._MailItem.get_Body() at MyLib.MyApp.OutlookAddin.MailProcessor.ProcessMailItem(MailItem mailItem) I'm pretty sure it is the digital signature causing the problem because if I forward the email back to myself, it will strip off the original sender's digital signature and the add-in application will process the email without any problems. I'm not sure what to do. I need to process the email, so I can't just ignore it. Somehow getting the body of the original email without throwing an exception would be ideal. Or I guess if I can identify that there is a digital signature associated with the email, I could forward the email to myself, but that seems a little messy. Does anyone have any suggestions/fixes? Thanks for any help.

    Read the article

  • STOP Application Pool Issue Programitically IIS7

    - by Sumit Kute
    In my application I needs to stop a application pool programmitically in IIS 7. I have created a local acccount and given him Administrative Priviledges. Here is the code Private static void StopApplication() { string serviceHostDeploymentType = "local"; if (serviceHostDeploymentType.Equals("local")) { WindowsIdentityImpersonate newIdentity = new WindowsIdentityImpersonate(); if (newIdentity.Impersonate("AccountName", Environment.MachineName, "Password")) { try { ServerManager serverManager = ServerManager.OpenRemote("Server"); string siteName = GetWebSiteNameById(serverManager, 1); Site parentWebsite = serverManager.Sites[siteName]; if (parentWebsite != null) { ApplicationPool apppool = serverManager.ApplicationPools["Application Pool Name"]; if (apppool != null) { apppool.Stop(); } } } finally { newIdentity.Undo(); } } } else { throw new ConfigurationErrorsException("..."); } } I am getting an error Access is denied. (Exception from HRESULT: 0x80070005 (E_ACCESSDENIED)). Stack Trace at Microsoft.Web.Administration.Interop.IAppHostMethodInstance.Execute() at Microsoft.Web.Administration.ConfigurationElement.ExecuteMethod(String methodName) at Microsoft.Web.Administration.ApplicationPool.Stop() at ServerManagerTesting.Form1.StopApplication() at ServerManagerTesting.Form1.button1_Click(Object sender, EventArgs e) at System.Windows.Forms.Control.OnClick(EventArgs e) at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent) at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ButtonBase.WndProc(Message& m) at System.Windows.Forms.Button.WndProc(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg) at System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(Int32 dwComponentID, Int32 reason, Int32 pvLoopData) at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context) at ServerManagerTesting.Program.Main() at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart()

    Read the article

  • Referencing .NET Assembly in VB6 won't work

    - by dretzlaff17
    I wrote a .net assembly using c# to perform functions that will be used by both managed and unmanaged code. I have a VB6 project that now needs to use the assembly via COM. I created my .net assembly, made sure that ComVisible is set to true and that it is registered for COM interop via project properties. public class MyClass [ComVisible(true)] public string GetResponse() { return "Testing Response" } } I build the assembly and copied the file into a folder. TestInterop.dll I then run a batch file to register the assembly tool to register the object for COM. cd C:\Windows\Microsoft.NET\Framework\v4.0.30319\ regasm "c:\Program Files\TestApp\TestInterop.dll" /tlb:TestInterop.tlb I open a new VB6 application and reference TestInterop.dll In VB6 I write the following code and it compiles. Dim obj as TestInterop.MyClass Set obj = new TestInterop.MyClass Dim strTest as string strTest = obj.GetRespose() When I run the program it errors on the obj.GetResponse() line. Run-time error' -2147024894 (80070002'): Automation error The system cannot find the file specified Also, the intellesense does not work on obj. I had to type the GetResponse method. Is this normal? Does anyone have any clue what could be wrong or what steps I missed. Thanks!

    Read the article

  • SQL Compact error: Unable to load DLL 'sqlceme35.dll'. The specified module could not be found

    - by Ciaran Bruen
    Hi - I'm developing a Winforms application using Visual Studio 2008 C# that uses a SQL compact 3.5 database on the client. The client will most likely be 32 bit XP or Vista machines. I'm using a standard Windows Installer project that creates an msi file and setup.exe to install the app on a client machine. I'm new to SQL compact so I haven't had to distribute a client database like this before now. When I run the setup.exe (on new Windows XP 32 bit with SP2 and IE 7) it installs fine but when I run the app I get the error below: Unable to load DLL 'sqlceme35.dll'. The specified module could not be found I spent a few hours searching this error already but all I can find are issues relating to installing on 64 bit Windows, none relating to normal 32 bit that I'm using. The install app copies the all the dependant files that it found into the specified install directory, including the System.Data.SqlServerCe.dll file (assembly version 3.5.1.0). The database file is in a directory called 'data' off the application directory, and the connection string for it is <add name="Tickets.ieOutlet.Properties.Settings.TicketsLocalConnectionString" connectionString="Data Source=|DataDirectory|\data\TicketsLocal.sdf" providerName="Microsoft.SqlServerCe.Client.3.5" /> Some questions I have: should the app be able to find the dll if it's in the same directory i.e. local to the app, or do I need to install it in the GAC? (If so cam I use the Windows Installer to install a dll in the GAC?) is there anything else I need to distribute with the app in order to use a Sql Compact database? there are other dlls also such as MS interop for exporting data to Excel on the client. Do these need to be installed in the GAC or will locating them in the application directory suffice? TIA, Ciaran.

    Read the article

  • Is it possible to use theme colors in Windows Forms apps?

    - by Yadyn
    I normally make use of System Colors whenever possible when designing Windows Forms applications just so that it'll fit in with the user's preferences. But is it possible to use Theme Colors? I realize that this limits you in several ways (must be running Windows that supports it and has the Themes service running), so I would certainly like it if it could fall back on some other default, but since I'm fairly sure 99% of my users will have it available, I'd like to make use of it if possible. Specifically, for newer Windows versions (Vista and 7), things like hyperlinks have a softer more pastel-ish blue. The old System Colors do not define anything for links and the like, and in general are much more limited (coming from the 95 days) in choices and variety. Though WPF probably has better support, I'm not at liberty to use it. If some third party utility, assembly, or the like is necessary, it would also need to be free to use. I don't need anything that fancy, but in a perfect world I would be able to do something like this: linkLabel1.LinkColor = System.Drawing.ThemeColors.Hyperlink; Am I stuck just using the default Blue (0,0,255) and having them look out of place in Vista and above? I'll even settle for ugly p/invoke interop methods if need be...

    Read the article

  • Can't write the SysWow64 value to registry with vbscript for Screensaver

    - by Valentein
    Scripts, registries, screen-savers, oh my! I'm trying to use a screen-saver on a Windows XP 64 bit machine which uses a .NET app which makes an interop call which relies on some x86 Shockwave Dlls (some Shockwave animation). Everything should be in the %systemroot%\WINNT\SysWOW64 directory. When the timeout for the screensaver occurs, the process should looks like this: Screensaver.scr - .NET app - shockwave animation. During installation I want a vbscript to my screen-saver file to copy the Screensaver.scr to the SysWow64 directory and then set the proper registry key to this file for Windows to launch the screen-saver. The code is something like this: Dim sScreenSaver, tScreenSaver sScreenSaver = "C:\SourceFiles\bin\ScreenSaver.scr" 'screensaver tScreenSaver = "C:\winnt\SysWOW64\" Set WshShell = WScript.CreateObject("WScript.Shell") 'script shell to run objects Set FSO = createobject("scripting.filesystemobject") 'file system object 'copy screensaver FSO.CopyFile sScreenSaver, tScreenSaver, True 'set screen saver Dim p1 p1 = "HKEY_CURRENT_USER\Control Panel\Desktop\" WshShell.RegWrite p1 & "SCRNSAVE.EXE", (tScreenSaver & "ScreenSaver.scr") After installation, I can verify the the Screensaver exists in the correct directory. (It actually seems to be in both the system32 and the sysWOW64 directories---whether that's the install script or something I did post-install I'm in the process of verifying.) However, the registry entry is not correct. In both the 32 and 64 bit regedit I see the HKCU\ControlPanel\Desktop\SCRNSAVE.EX is set to: C:\WINNT\system32\Screensaver.scr This isn't right. The screen-saver won't run from this directory. It only runs from SysWOW64. If I manually edit the registry with regedit to the correct SysWOW64 path everything works fine. Is this a problem with using the script or is this a Windows registry redirection, or filesystem redirection problem? You'd think this would be simple...

    Read the article

  • How to prepopulate an Outlook MailItem and avoiding a com Exception from the object model guard

    - by torrente
    Hi, I work for a company that develops a CRM tool and offers integration with MS Office(2003 & 2007) from windows XP to 7. (I'm working using Win7) My task is to call an Outlook instance (using C#) from this CRM tool when the user wants to send an email and prepopulate with data of the CRM tool (email, recipient, etc..) All of this already works just fine. The problem I'm having is that Outlook's "object model guard" is throwing com Exception (Operation aborted (Exception from HRESULT: 0x80004004 (E_ABORT))) the moment I try to read a protected value from the mailItem (such as mail.bodyHTML). Example Snippet: using MSOutlook = Microsoft.Office.Interop.Outlook; //untrusted Instance _outlook = new MSOutlook.Application(); MSOutlook.MailItem mail = (MSOutlook.MailItem)_outlook.CreateItem(MSOutlook.OlItemType.olMailItem); //this where the Exception occurs string outlookStdHTMLBody = mail.HTMLBody; I've done quite a bit of reading and know that my Outlook Instance (derived by using new Application) is considered untrusted and therefore the "omg" kicks in. I do have a workaround for development: I'm running VS2010 as Administrator and if I run Outlook as Administrator as well - all is good. I suppose this is due to them having the same integrity levels(high) and the UAC(?) is not complaining. But that just ain't the way to go for deployment. Now the question is: Is there a way to obtain a trusted instance of Outlook so that I can avoid this exception? I've already read that when developing an Office Add-In using VSTO one can obtain a trusted Instance from the OnComplete event and/or using "ThisAddin" But I "merely" want to start an outlook instance and preopulate it, and do not want to develop an Add-In since this is not the requirement. And to make it clear - I have no problem with pop ups informing the user that outlook is being accessed - I just want to get rid of the exception! So how can I get around this problem using code? Any help is highly appreciated! Thomas

    Read the article

  • 'License expired' error when dynamically generating Excel docs in ASP.NET

    - by Mac
    Anyone familiar with error below? When I run my webapp to generate a dynamic excel doc from my local machine it works fine but when the same piece of code is invoked on the server I get the below error. It seems like it's a permissions issues since it works on my machine but not the server but I don't know where to start in order to pinpoint the problem. Any guidance/help is greatly appreciated! Server Error in '/' Application. -------------------------------------------------------------------------------- This command is unavailable because the license to use this application has expired. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Runtime.InteropServices.COMException: This command is unavailable because the license to use this application has expired. Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [COMException (0x800a03ec): This command is unavailable because the license to use this application has expired.] Microsoft.Office.Interop.Excel.Workbooks.Add(Object Template) +0 PaymentsReport.Page_Load(Object sender, EventArgs e) +70 System.Web.Util.CalliHelper.EventArgFunctionCaller(IntPtr fp, Object o, Object t, EventArgs e) +15 System.Web.Util.CalliEventHandlerDelegateProxy.Callback(Object sender, EventArgs e) +34 System.Web.UI.Control.OnLoad(EventArgs e) +99 System.Web.UI.Control.LoadRecursive() +47 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +1061 Office/Excel is installed on the server and I can open/save excel docs on the server. Could it be the version of excel on the server vs. my local machine? If so how can I make sure I have the latest on the server?

    Read the article

  • How to implement two way binding between an ActiveX control and a WPF MVVM View Model

    - by Zamboni
    I have a WPF application implemented using the MVVM framework that uses an ActiveX control and I need to keep the WPF and ActiveX UI synchronised. So far I can update the ActiveX UI when I change the WPF UI using the code at the bottom of the question that I got from the article Hosting an ActiveX Control in WPF and this question. But I cannot update the WPF UI when I make a change in the ActiveX UI. I suspect that I need to fire the PropertyChanged event from my ActiveX control but I have no idea how to do this or if it is even possible. The ActiveX controls I have written are in VB6 and MFC as I am just prototying at this time for the eventual integration of VB6 ActiveX controls in a WPF contaner application. Here is a code snipet that indicates the work done so far: System.Windows.Forms.Integration.WindowsFormsHost host = new System.Windows.Forms.Integration.WindowsFormsHost(); // Create the ActiveX control. AxTEXTBOXActiveXLib.AxTEXTBOXActiveX axWmp = new AxTEXTBOXActiveXLib.AxTEXTBOXActiveX(); // Assign the ActiveX control as the host control's child. host.Child = axWmp; axWmp.DataBindings.Add(new System.Windows.Forms.Binding("ActiveXStatus", (MainWindowViewModel)this.DataContext, "ModelStatus", true, DataSourceUpdateMode.OnPropertyChanged )); // Add the interop host control to the Grid // control's collection of child controls. this.activexRow.Children.Add(host); How to implement two way binding between an ActiveX control and a WPF MVVM View Model?

    Read the article

  • Getting error while opening form in visual studio 2005

    - by Ravisha
    i am getting below excetion on opening a form on visual studio work bench Its not always but sometime it opens without any problem Does anyone has a solution for this? The path is not of a legal form. Hide at System.IO.Path.NormalizePathFast(String path, Boolean fullCheck) at System.IO.Path.NormalizePath(String path, Boolean fullCheck) at System.IO.Path.GetFullPathInternal(String path) at System.Reflection.AssemblyName.GetAssemblyName(String assemblyFile) at Microsoft.VisualStudio.Design.VSTypeResolutionService.AddProjectDependencies(Project project) at Microsoft.VisualStudio.Design.VSTypeResolutionService.AssemblyEntry.get_Assembly() at Microsoft.VisualStudio.Design.VSTypeResolutionService.AssemblyEntry.Search(String fullName, String typeName, Boolean ignoreTypeCase, Assembly& assembly, String description) at Microsoft.VisualStudio.Design.VSTypeResolutionService.SearchProjectEntries(AssemblyName assemblyName, String typeName, Boolean ignoreTypeCase, Assembly& assembly) at Microsoft.VisualStudio.Design.VSTypeResolutionService.GetType(String typeName, Boolean throwOnError, Boolean ignoreCase, ReferenceType refType) at Microsoft.VisualStudio.Design.Serialization.CodeDom.AggregateTypeResolutionService.GetType(String name, Boolean throwOnError, Boolean ignoreCase) at Microsoft.VisualStudio.Design.Serialization.CodeDom.AggregateTypeResolutionService.GetType(String name, Boolean throwOnError) at System.ComponentModel.Design.Serialization.CodeDomSerializerBase.GetType(ITypeResolutionService trs, String name, Dictionary2 names) at System.ComponentModel.Design.Serialization.CodeDomSerializerBase.FillStatementTable(IDesignerSerializationManager manager, IDictionary table, Dictionary2 names, CodeStatementCollection statements, String className) at System.ComponentModel.Design.Serialization.TypeCodeDomSerializer.Deserialize(IDesignerSerializationManager manager, CodeTypeDeclaration declaration) at System.ComponentModel.Design.Serialization.CodeDomDesignerLoader.PerformLoad(IDesignerSerializationManager manager) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomDesignerLoader.PerformLoad(IDesignerSerializationManager serializationManager) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomDesignerLoader.DeferredLoadHandler.Microsoft.VisualStudio.TextManager.Interop.IVsTextBufferDataEvents.OnLoadCompleted(Int32 fReload)

    Read the article

  • RegAsm for Class Library Used in VB6 Application

    - by michael.lukatchik
    To be short and to the point, I've built a C# class library that is both COM-Visible and Registered for COM Interop. I've compiled the library, which resulted in the generation of .dll and .tlb files. I have another machine that's running a VB6 application. So, I copied the .dll and .tlb files over to C:/Windows/system32 folder on the machine. I then registered those files using the following: C:\Windows\Microsoft.NET\Framework\v2.0.50727\RegAsm C:\Windows\system32\TestClass.dll /tlb:TestClass.tlb After the files were registered successfully, I added a project reference to the Test.tlb file from inside my VB6 app, then I tried to invoke a method in my new referenced class like so: Dim myObject As TestNamespace.TestClass Set myObject = New TestNamespace.TestClass MsgBox (myObject.TestMethod()) It doesn't work, and I receive a -2147024894 Automation Error. I've read that I shouldn't install the dll into a private folder like system32. I should either be registering in the GAC or I should be registering in another location using the "/codebase" option: C:\Windows\Microsoft.NET\Framework\v2.0.50727\RegAsm C:\TestClass.dll /tlb:TestClass.tlb /codebase Is there any reason I shouldn't be using system32? Past devs that have worked on this project have placed assembly files used by this VB6 project into system32 and there haven't seemed to be any issues. When I register my dll in the system32 location, I get the Automation Error. When I register my dll in another location (i.e. C:/), the method call into my class library from VB6 works as expected. What gives? I should mention that we will NOT be using the GAC to register any DLL's. That's just the way it is. Any help is appreciated. Mike

    Read the article

< Previous Page | 28 29 30 31 32 33 34 35 36  | Next Page >