Search Results

Search found 18161 results on 727 pages for 'cell array'.

Page 323/727 | < Previous Page | 319 320 321 322 323 324 325 326 327 328 329 330  | Next Page >

  • external drive enclosure -> software RAID 5?

    - by memilanuk
    Hello all, I have two older PCs on my LAN posing as 'servers'... one running FreeNAS off a USB stick using three 500GB hdds in a ZFS RAID-Z pool serving as storage for the LAN and one running Debian Lenny with an 80GB drive used as a general purpose 'tinker' box that I can ssh into, etc. Problem is that the SMART report for one of those 500GB drives in the FreeNAS box is showing some pre-failure attributes, and the whole array is a little small anyways. Rather than simply replace one 500GB drive with another 500GB drive, and have no backup of the file server, I'd like to upgrade all the drives to 2TB ones - but I have no where to store that much data in the mean while. As such, I started looking at getting a 4-bay external drive enclosure with an eSATA card for the Debian box, with the hopes of creating a RAID5 + LVM setup using those drives and backing the data up to that external drive enclosure. After the backup is done, replace the drives in the FreeNAS box and rebuild the array there and mirror the data back. Then, I'd have both the primary storage (on the FreeNAS box) and a backup (which I don't have currently) using the external drive enclosure on the Debian box. My big question is... most of these external drive boxes seem to claim support for JBOD, RAID 0, 1, 10, 5, etc. - should I presume that is simply fake RAID like many commodity mobos have, and not really usable in Linux? In that case, with all the drives hanging off the one eSATA connection, will Linux (specifically Debian Squeeze, as I plan on upgrading that box here shortly) see all four drives, or just the first one? Will I be able to configure them in a RAID5 array as desired? Thanks, Monte

    Read the article

  • Reinserted a RAID disk. Defined as foreign. Is import or clear the correct choice?

    - by Petrus
    I have re-inserted a RAID disk, on a DELL server with Windows Server 2008. The drive-status indicator was changing between a green and amber light, and the monitor gave the following message: There are offline or missing virtual drives with preserved cache. Please check the cables and ensure that all drives are present. Press any key to enter the configuration utility. I pressed a key and the PERC 6/I Integrated BIOS Configuration Utility showed that the RAID Status for that disk was Offline. After reinsertion of the disk the monitor is giving the following message: Foreign configuration(s) found on adapter. Press any key to continue or ‘C’ load the configuration utility, or press ‘F’ to import foreign configuration(s) and continue. After checking around on the net I am uncertain if I should choose import or clear. I cannot find out if an import means importing information from the array/system to the now foreign disk or the other way, i.e. importing information from the foreign disk to the array/system that was actually working fine. Also; if clear is a necessary thing to do ahead of a rebuild of that disk, or if clear means to clear the system to somehow make it ready to import the information from the foreign disk to the array/system, which is not what I want. I imagine that making the wrong choice here might be fatal. Please help clearing this out by telling what to choose and why.

    Read the article

  • Raid-5 Performance per spindle scaling

    - by Bill N.
    So I am stuck in a corner, I have a storage project that is limited to 24 spindles, and requires heavy random Write (the corresponding read side is purely sequential). Needs every bit of space on my Drives, ~13TB total in a n-1 raid-5, and has to go fast, over 2GB/s sort of fast. The obvious answer is to use a Stripe/Concat (Raid-0/1), or better yet a raid-10 in place of the raid-5, but that is disallowed for reasons beyond my control. So I am here asking for help in getting a sub optimal configuration to be as good as it can be. The array built on direct attached SAS-2 10K rpm drives, backed by a ARECA 18xx series controller with 4GB of cache. 64k array stripes and an 4K stripe aligned XFS File system, with 24 Allocation groups (to avoid some of the penalty for being raid 5). The heart of my question is this: In the same setup with 6 spindles/AG's I see a near disk limited performance on the write, ~100MB/s per spindle, at 12 spindles I see that drop to ~80MB/s and at 24 ~60MB/s. I would expect that with a distributed parity and matched AG's, the performance should scale with the # of spindles, or be worse at small spindle counts, but this array is doing the opposite. What am I missing ? Should Raid-5 performance scale with # of spindles ? Many thanks for your answers and any ideas, input, or guidance. --Bill Edit: Improving RAID performance The other relevant thread I was able to find, discusses some of the same issues in the answers, though it still leaves me with out an answer on the performance scaling.

    Read the article

  • Recovering Data from a Linkstation LS-WXL/R1

    - by kingkool68
    I've been running a Buffalo Linkstation LS-WXL/R1 in RAID1 for a few weeks. Two nights ago we had a brief power outage. Yesterday when I tried to mount the disk it couldn't be found. I logged in to the web admin and it couldn't see any storage attached and no arrays available. Well this sucks. I ended up taking the disks out and mounting them to an Ubuntu virtual machine. They how up as an Array but I can't start the Array to the best of my limited knowledge. I could still see the 6 partitions, so I'm confident the data is there. I can use Photorec (http://www.cgsecurity.org/wiki/PhotoRec) to recover most of the files I want, it just takes some time. Could I make an image of the data partition and mount that in Ubuntu so I can get at the data I want through the file system? 95% of the data on my Linkstation LS-WXL/R1 is backup. I just put a few folders of images on there that I need to get back. I'm already preparing to format the disks when I'm done and re-building the RAID1 array from scratch. Any advice would be appreciated.

    Read the article

  • Extend RAID 1 (HP SmartArray P410i) running Linux

    - by Oliver
    I took over a fairly simple server setup with the following RAID 1 config running Ubuntu 11.10 (Kernel 3.0.0-12-server x86_64): => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: removed) array A (SAS, Unused Space: 1335535 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 1 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 1 TB, OK) Initially there were two 300GB disks that got replaced by 1TB disks and I now have to extend the logical volume to use that extra space. However, when trying to do so I get the following warning: => ctrl slot=0 ld 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n) Is it safe to say yes or am I at risk of corrupting the file system / loosing data? Rearranging and extending the file system afterwards shouldn't be an issue as I can take the server offline and boot from a gparted live disk. Here's the config of the RAID controller in use: => ctrl all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: removed RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 5.12 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True And the partition table: Number Start End Size Type File system Flags 1 1049kB 274GB 274GB primary ext4 boot 2 274GB 300GB 25.8GB extended 5 274GB 300GB 25.8GB logical linux-swap(v1)

    Read the article

  • What does this mean: "SATP VMW_SATP_LOCAL does not support device configuration"?

    - by Jason Tan
    Can anyone tell me what this means in ESXi 5.1?: SATP VMW_SATP_LOCAL does not support device configuration I've googled it and I get a lot of results, but as yet all the pages that contain the string are discussing other matters. The storage array is a HDS HUS-VM and the hosts are HP b460c G8 blades with flex fabric and flex fabric VCs which I am in the process of commissioning and would like to get it started on the right foot - i.e. error and warning free! naa.600508b1001c56ee3d70da65f071da23 Device Display Name: HP Serial Attached SCSI Disk (naa.600508b1001c56ee3d70da65f071da23) Storage Array Type: VMW_SATP_LOCAL Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration. Path Selection Policy: VMW_PSP_FIXED Path Selection Policy Device Config: {preferred=vmhba0:C0:T0:L1;current=vmhba0:C0:T0:L1} Path Selection Policy Device Custom Config: Working Paths: vmhba0:C0:T0:L1 Is Local SAS Device: true Is Boot USB Device: false This is the same LUN: ~ # esxcli storage core device list -d naa.60060e80132757005020275700000016 naa.60060e80132757005020275700000016 Display Name: HITACHI Fibre Channel Disk (naa.60060e80132757005020275700000016) Has Settable Display Name: true Size: 204800 Device Type: Direct-Access Multipath Plugin: NMP Devfs Path: /vmfs/devices/disks/naa.60060e80132757005020275700000016 Vendor: HITACHI Model: OPEN-V Revision: 5001 SCSI Level: 2 Is Pseudo: false Status: degraded Is RDM Capable: true Is Local: false Is Removable: false Is SSD: false Is Offline: false Is Perennially Reserved: false Queue Full Sample Size: 0 Queue Full Threshold: 0 Thin Provisioning Status: unknown Attached Filters: VAAI_FILTER VAAI Status: supported Other UIDs: vml.020001000060060e801327570050202757000000164f50454e2d56 Is Local SAS Device: false Is Boot USB Device: false ~ #

    Read the article

  • Raid1 with active and spare partition

    - by Daniel Baron
    I am having the following problem with a RAID1 software raid partition on my Ubuntu system (10.04 LTS, 2.6.32-24-server in case it matters). One of my disks (sdb5) reported I/O errors and was therefore marked faulty in the array. The array was then degraded with one active device. Hence, I replaced the harddisk, cloned the partition table and added all new partitions to my raid arrays. After syncing all partitions ended up fine, having 2 active devices - except one of them. The partition which reported the faulty disk before, however, did not include the new partition as an active device but as a spare disk: md3 : active raid1 sdb5[2] sda5[1] 4881344 blocks [2/1] [_U] A detailed look reveals: root@server:~# mdadm --detail /dev/md3 [...] Number Major Minor RaidDevice State 2 8 21 0 spare rebuilding /dev/sdb5 1 8 5 1 active sync /dev/sda5 So here is the question: How do I tell my raid to turn the spare disk into an active one? And why has it been added as a spare device? Recreating or reassembling the array is not an option, because it is my root partition. And I can not find any hints to that subject in the Software Raid HOWTO. Any help would be appreciated.

    Read the article

  • My Computer hangs for a few minutes just after startup, and then is fine.

    - by EvilChookie
    So I just built myself a reasonably beefy computer, and I installed Windows 7 on it. However, I start the machine up each morning and within a few minutes, the computer will semi hang. That is the mouse is responsive, and most of the time I can open task manager, or a new tab in Chrome. Occasionally windows will be labelled as 'Not responding'. Then, the machine will get over it's problem, and will be nice and quick until I turn it off. Here's my specs: CPU: AMD Phenom-II X4 955 Black (Quad Core, 3.2ghz) RAM: 4GB of DDR3 1300 MOBO: ASUS M4A785T-M (Latest BIOS) HARD DRIVES: 2x1TB Western Digital Caviar Blacks in RAID-0. OS: Windows 7 Ultimate x64. GPU: ASUS GT240 1GB. I believe this issue relates to the RAID array, as I didn't have the lockup problem before I created the array. I purchased a second drive and reformatted after creating a RAID array, since the single drive was a little on the pokey side (compared to the rest of the computer). What I have tried: Updated Raid Drivers Malware checks Windows Updates Unecessary Services CPU and Disk activity appears to be low (via Resource Monitor) No strange errors in the error log. Any thoughts?

    Read the article

  • Adding third disk as a single disk in a server with an existing RAID1

    - by slowhandsolo
    I've got a ProLiant DL360 G5 server (Fedora 13) with two SAS disks in a hardware RAID 1, working fine. Now I hot plugged another SAS disk. I'd like to configure this new hard disk out of my RAID, as a single non-RAID disk (ex. /dev/sdb). Even after rebooting the server, I can't see the new disk with "fdisk -l". It displays only my hardware RAID, but not the new disk. [root@myserver]# fdisk -l Disco /dev/cciss/c0d0: 300.0 GB, 299966445568 bytes Disposit. Inicio Comienzo Fin Bloques Id Sistema /dev/cciss/c0d0p1 * 1 126 512000 83 Linux /dev/cciss/c0d0p2 126 71798 292422656 8e Linux LVM Disco /dev/dm-0: 234.9 GB, 234881024000 bytes Disco /dev/dm-1: 10.5 GB, 10536091648 bytes Disco /dev/dm-2: 21.0 GB, 20971520000 bytes Disco /dev/dm-3: 31.5 GB, 31474057216 bytes Disco /dev/dm-4: 1577 MB, 1577058304 bytes However, I can see the new disk using the HP Array Configuration Utility CLI for Linux "hpacucli": [root@myserver]# hpacucli => controller slot=0 physicaldrive all show status physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 300 GB): OK physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 300 GB): OK physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 300 GB): OK => controller slot=0 pd all show detail Smart Array P400i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 **unassigned** physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: **Unassigned Drive** As you can see, I've got two SAS disks in a RAID 1 and the new disk as "unassigned". Is there any way to work with the new disk as another non-RAID single disk? If relevant, I want to create a new partition in my new disk, format it with mkfs and mount it, but as I can't see it with fdisk, I don't know how to do it. Thanks!

    Read the article

  • Windows authentication to SQL Server via IIS and PHP

    - by Jeff
    We're running a PHP 5.4 application on Server 2008 R2. We would like to connect to a SQL Server 2008 database, on a separate server, using Windows authentication (must be Windows authentication--the DB admins won't let us connect any other way). I have downloaded the SQL Server drivers for PHP and installed them. IIS is configured for Windows authentication, and anonymous authentication has been disabled. $_SERVER['AUTH_USER'] reports our currently logged on Windows account. In php.ini, we have set fastcgi.impersonate = 1. When we setup a connection using the following code from Microsoft: $serverName = "sqlserver\sqlserver"; $connectionInfo = array( "Database"=>"some_db"); /* Connect using Windows Authentication. */ $conn = sqlsrv_connect( $serverName, $connectionInfo); if( $conn === false ) { echo "Unable to connect.</br>"; die( print_r( sqlsrv_errors(), true)); } We are presented with the following error message: Unable to connect. Array ( [0] => Array ( [0] => 28000 [SQLSTATE] => 28000 [1] => 18456 [code] => 18456 [2] => [Microsoft][SQL Server Native Client 11.0][SQL Server]Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. [message] => [Microsoft][SQL Server Native Client 11.0][SQL Server]Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. ) Is it possible to connect to SQL Server 2008 via PHP using Windows authentication? Are there any additional required settings we need to make on IIS, SQL Server, or any other component (like a domain controller)?

    Read the article

  • Converting software RAID1 to RAID10 for /boot

    - by luckytaxi
    Array info: /dev/md0 - /dev/sda1 and /dev/sdb1 /dev/md2 - /dev/sda2 and /dev/sdb2 Partition info: /boot - /dev/md0 / - /dev/md1 I have two drives that are setup as RAID1 using software RAID on Redhat. I added two additional drives (same size) and I would like to conver the RAID1 to a RAID10. The problem I'm having is adding the last drive to the array. I've gotten as far as creating a RAID10 with two missing devices but as soon as I add the last drive, all hell breaks loose. It seems /dev/sda1 is the culprit. What I'm not too sure about is how to create the RAID10. I've tried the following mdadm --create /dev/md2 --level=raid10 --raid-device=4 /dev/sdc1 missing /dev/sdd1 missing I then proceeded to fail /dev/sdb1 from /dev/md0 and added that partition to /dev/md2. I proceeded to install the MBR on EACH partition since boot resides on /dev/sdx1 on each drive. As a test, all is well, I'm able to boot back into the system once I do a quick reboot. Now, when I go add the last drive /dev/sda1, it breaks. I attempted to install grub on /dev/sda1 and I get the following ... grub> root (hd0,0) /dev/sda root (hd0,0) /dev/sda Filesystem type is ext2fs, partition type 0xfd grub> setup (hd0) setup (hd0) Checking if "/boot/grub/stage1" exists... no Checking if "/grub/stage1" exists... no Error 2: Bad file or directory type At this point, the array is hosed I believe. I rebooted the server and it refuses to boot.

    Read the article

  • How to interrupt software raid resync?

    - by Adam5
    I want to interrupt a running resync operation on a debian squeeze software raid. (This is the regular scheduled compare resync. The raid array is still clean in such a case. Do not confuse this with a rebuild after a disk failed and was replaced.) How to stop this scheduled resync operation while it is running? Another raid array is "resync pending", because they all get checked on the same day (sunday night) one after another. I want a complete stop of this sunday night resyncing. [Edit: sudo kill -9 1010 doesn't stop it, 1010 is the PID of the md2_resync process] I would also like to know how I can control the intervals between resyncs and the remainig time till the next one. [Edit2: What I did now was to make the resync go very slow, so it does not disturb anymore: sudo sysctl -w dev.raid.speed_limit_max=1000 taken from http://www.cyberciti.biz/tips/linux-raid-increase-resync-rebuild-speed.html During the night I will set it back to a high value, so the resync can terminate. This workaround is fine for most situations, nonetheless it would be interesting to know if what I asked is possible. For example it does not seem to be possible to grow an array, while it is resyncing or resyncing "pending"]

    Read the article

  • How to re-add a RAID-10 failed drive on Ubuntu?

    - by thiesdiggity
    I have a problem that I can't seem to solve. We have a Ubuntu server setup with RAID-10 and two of the drives dropped out of the array. When I try to re-add them using the following command: mdadm --manage --re-add /dev/md2 /dev/sdc1 I get the following error message: mdadm: Cannot open /dev/sdc1: Device or resource busy When I do a "cat /proc/mdstat" I get the following: Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [r$ md2 : active raid10 sdb1[0] sdd1[3] 1953519872 blocks 64K chunks 2 near-copies [4/2] [U__U] md1 : active raid1 sda2[0] sdc2[1] 468853696 blocks [2/2] [UU] md0 : active raid1 sda1[0] sdc1[1] 19530688 blocks [2/2] [UU] unused devices: <none> When I run "/sbin/mdadm --detail /dev/md2" I get the following: /dev/md2: Version : 00.90 Creation Time : Mon Sep 5 23:41:13 2011 Raid Level : raid10 Array Size : 1953519872 (1863.02 GiB 2000.40 GB) Used Dev Size : 976759936 (931.51 GiB 1000.20 GB) Raid Devices : 4 Total Devices : 2 Preferred Minor : 2 Persistence : Superblock is persistent Update Time : Thu Oct 25 09:25:08 2012 State : active, degraded Active Devices : 2 Working Devices : 2 Failed Devices : 0 Spare Devices : 0 Layout : near=2, far=1 Chunk Size : 64K UUID : c6d87d27:aeefcb2e:d4453e2e:0b7266cb Events : 0.6688691 Number Major Minor RaidDevice State 0 8 17 0 active sync /dev/sdb1 1 0 0 1 removed 2 0 0 2 removed 3 8 49 3 active sync /dev/sdd1 Output of df -h is: Filesystem Size Used Avail Use% Mounted on /dev/md1 441G 2.0G 416G 1% / none 32G 236K 32G 1% /dev tmpfs 32G 0 32G 0% /dev/shm none 32G 112K 32G 1% /var/run none 32G 0 32G 0% /var/lock none 32G 0 32G 0% /lib/init/rw tmpfs 64G 215M 63G 1% /mnt/vmware none 441G 2.0G 416G 1% /var/lib/ureadahead/debugfs /dev/mapper/RAID10VG-RAID10LV 1.8T 139G 1.6T 8% /mnt/RAID10 When I do a "fdisk -l" I can see all the drives needed for the RAID-10. The RAID-10 is part of the /dev/mapper, could that be the reason why the device is coming back as busy? Anyone have any suggestions on what I can try to get the drives back into the array? Any help would be greatly appreciated. Thanks!

    Read the article

  • Which type RAM support Our Servers?

    - by Mikunos
    I need to increase the RAM in our DELL servers but with the lshw I cannot see if the RAM installed is a UDIMM or RDIMM. Handle 0x1100, DMI type 17, 28 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 2048 MB Form Factor: DIMM Set: 1 Locator: DIMM_A1 Bank Locator: Not Specified Type: <OUT OF SPEC> Type Detail: Synchronous Speed: 1333 MHz (0.8 ns) Manufacturer: 00CE00B380CE Serial Number: 8244850B Asset Tag: 02103961 Part Number: M393B5773CH0-CH9 Handle 0x1101, DMI type 17, 28 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 2048 MB Form Factor: DIMM Set: 1 Locator: DIMM_A2 Bank Locator: Not Specified Type: <OUT OF SPEC> Type Detail: Synchronous Speed: 1333 MHz (0.8 ns) Manufacturer: 00CE00B380CE Serial Number: 8244855D Asset Tag: 02103961 Part Number: M393B5773CH0-CH9 Handle 0x1102, DMI type 17, 28 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 2048 MB Form Factor: DIMM Set: 2 Locator: DIMM_A3 Bank Locator: Not Specified Type: <OUT OF SPEC> Type Detail: Synchronous Speed: 1333 MHz (0.8 ns) Manufacturer: 00CE00B380CE Serial Number: 8244853E Asset Tag: 02103961 Part Number: M393B5773CH0-CH9 how have we do to know which is the right RAM memory to buy? thanks

    Read the article

  • Possible disk IO issue

    - by Tim Meers
    I've been trying to really figure out what my IOPS are on my DB server array and see if it's just too much. The array is four 72.6gb 15k rpm drives in RAID 5. To calculate IOPS for RAID 5 the following formula is used: (reads + (4 * Writes)) / Number of disks = total IOPS. The formula is from MSDN. I also want to calculate the Avg Queue Length but I'm not sure where they are getting the formula from, but i think it reads on that page as avg que length/number of disks = actual queue. To populate that formula I used the perfmon to gather the needed information. I came up with this, under normal production load: (873.982 + (4 * 28.999)) / 4 = 247.495. Also the disk queue lengh of 14.454/4 = 3.614. So to the question, am I wrong in thinking this array has a very high disk IO? Edit I got the chance to review it again this morning under normal/high load. This time with even bigger numbers and IOPS in excess of 600 for about 5 minutes then it died down again. But I also took a look at the Avg sec/Transfer, %Disk Time, and %Idle Time. These number were taken when the reads/writes per sec were only 332.997/17.999 respectively. %Disk Time: 219.436 %Idle Time: 0.300 Avg Disk Queue Length: 2.194 Avg Disk sec/Transfer: 0.006 Pages/sec: 2927.802 % Processor Time: 21.877 Edit (again) Looks like I have that issue solved. Thanks for the help. Also for a pretty slick parser I found this: http://pal.codeplex.com/ It works pretty well for breaking down the data into something usable.

    Read the article

  • Flash Backed Write Cache (FBWC) without capacitor pack

    - by Martyn
    I brought a HP Smart Array P410 controller and it is installed and working fine in a HP Prolient Microserver with 4 drives in two RAID 1 arrays. I didn’t realise however that it came without any cache so would only work by directly writing straight to the disk, and the performance was horrible. So I then brought the 512MB Flash Backed Write Cache (FBWC) memory module as I was under the impression that with FBWC I would not need a battery. I got this idea from a forum post. "What do you guys think of the choice between 'BBWC' (battery backed write cache) and 'FBWC' (flash backed write cache)? The flashed based ones use non-volitile memory so need no battery." After installing the cache module however the server pretty much won’t boot. The P410 has a flashing amber light on it, and from the manual that doesn’t sound good. I’ve managed to get to the on board BIOS once and even managed to get to boot to the HP Array Configuration Utility (ACU) CD once, but every other time the Server continuingly reboots once it get to the POST screen and reads ARRAY INITILIZING %%%. The one time I reached the ACU, it reported a problem with the Cache Module. To me, it seems like the cache module is faulty, however the supplier tells me “Do you have an FBWC battery pack, p/n 587324-001, because that is required for the cache to work. If you have it, please complete an RMA form and we'll send a replacement / credit.” Does this sound right to you? I’ve been ordering the parts from the US and I don’t want to spend $77 + $40 p&p on a battery, wait a week for the shipping to find the card is faulty, and I don’t want to send back a working card?

    Read the article

  • Recommended Win2k8 Server software to fix my RAID-0 issue

    - by Jason Kealey
    I'm running an Asus P6T V2 Deluxe. It has six SATA ports and supports onboard RAID. I am using two of those ports for a RAID0 array of 1.5TB Seagate drives using the onboard RAID controller. One of them is giving me SMART warnings and I want to preemptively replace it. I pulled out two other 1.5TB drives from another computer and am ready to use one or both, if necessary. I can't run any SMART diagnostic software from within Windows because it only sees the hardware RAID-0 array, not each individual drive. The first thing I tried was a slow sector-by-sector copy using a free tool called EASEUS Disk Copy. Used the bootdisk, copied (took like 16 hours), unplugged the defective drive and plugged the new one in its place. The motherboard didn't recognize the new drive as being part of the known setup, so it did not want to boot. The second thing I tried was using other software (I forget the name) to copy the partition from within Windows. The first software failed because I had a server operating system. I found another software (I forget the name) which supported a server OS and did a partition copy onto the new drive. This seemed to work and the OS started to boot, but blue screened and started a reboot cycle. I'm assuming the software I was using was no good as it was trying to copy the boot disk while it was in use. I am looking for recommendations on what software to use to fix my problem without doing a re-install. Everything is backed up but my computer works fine and I'd like to avoid re-installation when possible. However, my system would be back up now if I had just started over on a second RAID array. :)

    Read the article

  • RAID5 issue after replacing motherboard and upgrading firmware

    - by 8steve8
    ok so ive had a 4x2TB(samsung HD204UI w/firmware patch) raid5 array working normally for about a month. It was in a h57 gigabyte motherboard using the intel raid with Windows 7 x64. Today I got an intel h67 motherboard, so I upgraded the intel raid drivers to 10.1.0.1008 from 9.6.0.1014, and I'm not sure if i checked after a reboot, but it caused no problems. I swapped in the new dh67 motherboard, and my array status was "failed". 2 of the 4 drives listed themselves as members, while the other two drives listed themselves as non-members. I tried going back to the old h57 mobo, and downgrading the raid drivers, but the issue remains. It's not port dependent, 2 of the drives always come up as non-members regardless of what port or motherboard they are plugged into. This screenshot should show that the SNs match, which raises the question why the software doesn't realize the drive is a member of the array. I'd like to know if anyone has experienced anything similar, and what should I do, can I force the drive to be recognized as a member (without wiping data)?

    Read the article

  • Linux RAID: Replacing Failed Drive...permanantly

    - by user137519
    Okay, odd question here. I have a server with RAID 5. A drive failed, in a really physically in a really odd way. On the machine it boots and is seen by the BIOS but...no partition can be seen on the drive consistantly (in and out). 2 out of 3 drives working...I made new spare disk and added it, RAID 5 rebuilt clean. All appears well but...when I reboot it keeps trying to use the 2nd drive which doesn't give any partition data, so of course the RAID 5 gets 2 out of 3...again. The status of my drive is as follows: /dev/sda2:Good /dev/sdb2 (drive has physical problem so no partition data) bad, /dev/sdc2:good /dev/sdd2:good. Every time I reboot the mdadm system seems to keep trying to use /dev/sdb which has physical failure (although spins and is detected). /dev/sdd is the new drive I created. I added /dev/sdd to the raid and it rebuilds the raid but this action isn't memorized upon reboot so it keeps listing /dev/sda and /dev/sdc but doesn't use the perfectly good /dev/sdd until I re-add manually. I've tried removing the dead drive with the mdadm tool, but as it cannot see /dev/sdb paritions it will not fail or remove it (says partition doesn't exist). the /etc/mdadm.conf was automatically made on the original OS install which only lists: DEVICE partitions MAILADDR root ARRAY /dev/md2 super-minor=2 ARRAY /dev/md0 super-minor=0 ARRAY /dev/md1 super-minor=1 Basically just the raids to use on boot. I need to remove this semi-dead drive (/dev/sdb) but I'd prefer to know why this is happening before I do. any ideas or suggestions. I supposed I could attempt to clone/replace /dev/sdb (the partitions on drive show up, then disappear shortly after) but given the partition "chester cat" behaviour this seems risky to me and as I have a working "spare" it seems unnecessary. Thanks in advance for your insight.

    Read the article

  • 20 1TB drives vs. 10 2TB drives in RAID5/6 server

    - by Hunter
    Hi everyone, I will be setting up a server at work and I need some advice on some details. The setup will be one blade-type server (8-core, 16GB RAM) with two subsystems - one for the main storage the other to back it up. I'm shooting for a 20TB array (I know it'll be less after formatting and parity drives). So is there any advantage one way or the other with either 20 1TB drives or 10 2TB drives? I'm not sure right now how many controllers I should have either (in the quote I have is a dual-port controller). I would think two controllers for a server of this size would be a better choice than the dual-port controller (but I really don't know). And would an array of this size have any performance issues in RAID 5 or 6 (I know RAID 5 or 6 are "slower" because of all the parity calculations). Also, these will be either WD RE3 (1TB) or the RE4 (2TB). Oh, also, for the backup array would it be ok to use the WD 2TB green drives (also in RAID5 or 6)?

    Read the article

  • strange raid5 issue:

    - by 8steve8
    ok so ive had a 4x2TB(samsung HD204UI w/firmware patch) raid5 array working normally for about a month. It was in a h57 gigabyte motherboard using the intel raid with windows 7 x64. Today I got an intel h67 motherboard, so I upgraded the intel raid drivers to 10.1.0.1008 from 9.6.0.1014, and I'm not sure if i checked after a reboot, but it caused no problems. I swapped in the new dh67 motherboard, and my array status was "failed". 2 of the 4 drives listed themselves as members, while the other two drives listed themselves as non-members. I tried going back to the old h57 mobo, and downgrading the raid drivers, but the issue remains. It's not port dependent, 2 of the drives always come up as non-members regardless of what port or motherboard they are plugged into. the screenshot should show that the SNs match, which begs the question why the software doesn't realize the drive is a member of the array: http://img837.imageshack.us/img837/6145/both.png I'd like to know if anyone has experienced anything similar, and what should i do, can i force the drive to be recognized as a member (without wiping data)?

    Read the article

  • strange raid5 issue: [closed]

    - by 8steve8
    ok so ive had a 4x2TB(samsung HD204UI w/firmware patch) raid5 array working normally for about a month. It was in a h57 gigabyte motherboard using the intel raid with windows 7 x64. Today I got an intel h67 motherboard, so I upgraded the intel raid drivers to 10.1.0.1008 from 9.6.0.1014, and I'm not sure if i checked after a reboot, but it caused no problems. I swapped in the new dh67 motherboard, and my array status was "failed". 2 of the 4 drives listed themselves as members, while the other two drives listed themselves as non-members. I tried going back to the old h57 mobo, and downgrading the raid drivers, but the issue remains. It's not port dependent, 2 of the drives always come up as non-members regardless of what port or motherboard they are plugged into. the screenshot should show that the SNs match, which begs the question why the software doesn't realize the drive is a member of the array: http://img837.imageshack.us/img837/6145/both.png I'd like to know if anyone has experienced anything similar, and what should i do, can i force the drive to be recognized as a member (without wiping data)?

    Read the article

  • Windows 8 Killed my SSDs

    - by SLaks
    I have a computer running 2 256GB Crucial M4's (CT256M4SSD2) in a RAID 0 (striped) array on an ASUS P9X79 Pro using Intel's (built-in) RAID system. I recently installed Windows 8 Pro as UEFI on this RAID array. (wiping a fully-function Windows 7 non-UEFI installation) Now, whenever the computer is left running for about an hour, the system no longer sees those drives. Since those drives contain Windows, this leads to various forms of BSODs. If I Intel RSTe (RAID manager) is running at the time, it will say that the disk backing that RAID array has been removed. Once this happens, if I reset the computer, it will no longer boot. Entering BIOS setup shows that the SATA 3 (6Gbps) ports that those disks are connected to are both empty. If I then power down the system completely, then turn it on again, the drives reappear, but the problem repeats after another hour or so. I have inconclusively determined that the problem occurs even if Windows is not running (booted into the installation environment from a UEFI flash drive) I don't think there has been any data corruption since this started happening, although I have had two strange issues with a GIT repo on that disk. sfc /ScanNow and Intel's disk check (in RSTe) both do not find anything. Does anyone know what might cause this?

    Read the article

  • Rendering a random generated maze in WinForms.NET

    - by Claus Jørgensen
    Hi I'm trying to create a maze-generator, and for this I have implemented the Randomized Prim's Algorithm in C#. However, the result of the generation is invalid. I can't figure out if it's my rendering, or the implementation that's invalid. So for starters, I'd like to have someone take a look at the implementation: maze is a matrix of cells. var cell = maze[0, 0]; cell.Connected = true; var walls = new HashSet<MazeWall>(cell.Walls); while (walls.Count > 0) { var randomWall = walls.GetRandom(); var randomCell = randomWall.A.Connected ? randomWall.B : randomWall.A; if (!randomCell.Connected) { randomWall.IsPassage = true; randomCell.Connected = true; foreach (var wall in randomCell.Walls) walls.Add(wall); } walls.Remove(randomWall); } Here's a example on the rendered result: Edit Ok, lets have a look at the rendering part then: private void MazePanel_Paint(object sender, PaintEventArgs e) { int size = 20; int cellSize = 10; MazeCell[,] maze = RandomizedPrimsGenerator.Generate(size); mazePanel.Size = new Size( size * cellSize + 1, size * cellSize + 1 ); e.Graphics.DrawRectangle(Pens.Blue, 0, 0, size * cellSize, size * cellSize ); for (int y = 0; y < size; y++) for (int x = 0; x < size; x++) { foreach(var wall in maze[x, y].Walls.Where(w => !w.IsPassage)) { if (wall.Direction == MazeWallOrientation.Horisontal) { e.Graphics.DrawLine(Pens.Blue, x * cellSize, y * cellSize, x * cellSize + cellSize, y * cellSize ); } else { e.Graphics.DrawLine(Pens.Blue, x * cellSize, y * cellSize, x * cellSize, y * cellSize + cellSize ); } } } } And I guess, to understand this we need to see the MazeCell and MazeWall class: namespace MazeGenerator.Maze { class MazeCell { public int Column { get; set; } public int Row { get; set; } public bool Connected { get; set; } private List<MazeWall> walls = new List<MazeWall>(); public List<MazeWall> Walls { get { return walls; } set { walls = value; } } public MazeCell() { this.Connected = false; } public void AddWall(MazeCell b) { walls.Add(new MazeWall(this, b)); } } enum MazeWallOrientation { Horisontal, Vertical, Undefined } class MazeWall : IEquatable<MazeWall> { public IEnumerable<MazeCell> Cells { get { yield return CellA; yield return CellB; } } public MazeCell CellA { get; set; } public MazeCell CellB { get; set; } public bool IsPassage { get; set; } public MazeWallOrientation Direction { get { if (CellA.Column == CellB.Column) { return MazeWallOrientation.Horisontal; } else if (CellA.Row == CellB.Row) { return MazeWallOrientation.Vertical; } else { return MazeWallOrientation.Undefined; } } } public MazeWall(MazeCell a, MazeCell b) { this.CellA = a; this.CellB = b; a.Walls.Add(this); b.Walls.Add(this); IsPassage = false; } #region IEquatable<MazeWall> Members public bool Equals(MazeWall other) { return (this.CellA == other.CellA) && (this.CellB == other.CellB); } #endregion } }

    Read the article

  • CSG operations on implicit surfaces with marching cubes [SOLVED]

    - by Mads Elvheim
    I render isosurfaces with marching cubes, (or perhaps marching squares as this is 2D) and I want to do set operations like set difference, intersection and union. I thought this was easy to implement, by simply choosing between two vertex scalars from two different implicit surfaces, but it is not. For my initial testing, I tried with two spheres circles, and the set operation difference. i.e A - B. One circle is moving and the other one is stationary. Here's the approach I tried when picking vertex scalars and when classifying corner vertices as inside or outside. The code is written in C++. OpenGL is used for rendering, but that's not important. Normal rendering without any CSG operations does give the expected result. void march(const vec2& cmin, //min x and y for the grid cell const vec2& cmax, //max x and y for the grid cell std::vector<vec2>& tri, float iso, float (*cmp1)(const vec2&), //distance from stationary circle float (*cmp2)(const vec2&) //distance from moving circle ) { unsigned int squareindex = 0; float scalar[4]; vec2 verts[8]; /* initial setup of the grid cell */ verts[0] = vec2(cmax.x, cmax.y); verts[2] = vec2(cmin.x, cmax.y); verts[4] = vec2(cmin.x, cmin.y); verts[6] = vec2(cmax.x, cmin.y); float s1,s2; /********************************** ********For-loop of interest****** *******Set difference between **** *******two implicit surfaces****** **********************************/ for(int i=0,j=0; i<4; ++i, j+=2){ s1 = cmp1(verts[j]); s2 = cmp2(verts[j]); if((s1 < iso)){ //if inside circle1 if((s2 < iso)){ //if inside circle2 scalar[i] = s2; //then set the scalar to the moving circle } else { scalar[i] = s1; //only inside circle1 squareindex |= (1<<i); //mark as inside } } else { scalar[i] = s1; //inside neither circle } } if(squareindex == 0) return; /* Usual interpolation between edge points to compute the new intersection points */ verts[1] = mix(iso, verts[0], verts[2], scalar[0], scalar[1]); verts[3] = mix(iso, verts[2], verts[4], scalar[1], scalar[2]); verts[5] = mix(iso, verts[4], verts[6], scalar[2], scalar[3]); verts[7] = mix(iso, verts[6], verts[0], scalar[3], scalar[0]); for(int i=0; i<10; ++i){ //10 = maxmimum 3 triangles, + one end token int index = triTable[squareindex][i]; //look up our indices for triangulation if(index == -1) break; tri.push_back(verts[index]); } } This gives me weird jaggies: It looks like the CSG operation is done without interpolation. It just "discards" the whole triangle. Do I need to interpolate in some other way, or combine the vertex scalar values? I'd love some help with this. A full testcase can be downloaded HERE EDIT: Basically, my implementation of marching squares works fine. It is my scalar field which is broken, and I wonder what the correct way would look like. Preferably I'm looking for a general approach to implement the three set operations I discussed above, for the usual primitives (circle, rectangle/square, plane)

    Read the article

< Previous Page | 319 320 321 322 323 324 325 326 327 328 329 330  | Next Page >