Search Results

Search found 968 results on 39 pages for 'six fourty'.

Page 33/39 | < Previous Page | 29 30 31 32 33 34 35 36 37 38 39  | Next Page >

  • Javascript Regex: Testing string for intelligent query

    - by Shyam
    Hi, I have a string that holds user input. This string can contain various types of data, like: a six digit id a zipcode that contains out of 4 digits and two alphanumeric characters a name (characters only) As I am using this string to search through a database, the query type is determined on the type of search, which i want to handle serverside using JavaScript (yes, I am using JavaScript serverside). Searching on StackOverflow, brought me some interesting information, like the .test-method, which seems perfect for my needs. The test-method returns either true or false based on the evaluation on the string using a regex object. I am using this page as a reference: http://www.javascriptkit.com/jsref/regexp.shtml So I am trying to determine the zipcode, by using the following very noobish regex. var r = /[A-Za-z]{2,2}/ As far I can understand, this should limit the amount of occurrences of alphanumeric characters to a maximum of two. See beneath the output of my JavaScript console. > var r = /[A-Za-z]{2,2}/ > var x = "2233AL" > r.test(x) true > var x = "2233A" > r.test(x) false > var x = "2233ALL" > r.test(x) true /* i want this to be false */ > A little help would be really appreciated!

    Read the article

  • Guidance on E-commerce in a Python Framework

    - by Ant
    I am looking for guidance in making decisions on using Python for E-commerce. My reasoning to use Python in the first place is i do a lot of 3D so it's a real help to use Python for web server side as well as 3D so I do not need to learn a new language. When I say E-commerce i mean the logic behind displaying products and a check out system that is Robust....and yes I really want to build this myself so I can change it. I do not want to use an out the box solution that costs a lot of money every month. I want control of server side, data bases, e-commerce etc. My questions are: What Frameworks are out there? I looked at previous questions on stackoverflow but only found old posts about Sachmo and Get paid. What is the learning path, I do not want to make a mistake that costs six months of studying? Python then Django? How long if I spent 10 hours a day studying this would it take to get up and running? I write javaScript badly, so I am not a complete noob, I understand the basics of programming languages. many thanks in advance

    Read the article

  • The best way to return related data in a SQL statement

    - by Darvis Lombardo
    I have a question on the best method to get back to a piece of data that is in a related table on the other side of a many-to-many relationship table. My first method uses joins to get back to the data, but because there are multiple matching rows in the relationship table, I had to use a TOP 1 to get a single row result. My second method uses a subquery to get the data but this just doesn't feel right. So, my question is, which is the preferred method, or is there a better method? The script needed to create the test tables, insert data, and run the two queries is below. Thanks for your advice! Darvis -------------------------------------------------------------------------------------------- -- Create Tables -------------------------------------------------------------------------------------------- DECLARE @TableA TABLE ( [A_ID] [int] IDENTITY(1,1) NOT NULL, [Description] [varchar](50) NULL) DECLARE @TableB TABLE ( [B_ID] [int] IDENTITY(1,1) NOT NULL, [A_ID] [int] NOT NULL, [Description] [varchar](50) NOT NULL) DECLARE @TableC TABLE ( [C_ID] [int] IDENTITY(1,1) NOT NULL, [Description] [varchar](50) NOT NULL) DECLARE @TableB_C TABLE ( [B_ID] [int] NOT NULL, [C_ID] [int] NOT NULL) -------------------------------------------------------------------------------------------- -- Insert Test Data -------------------------------------------------------------------------------------------- INSERT INTO @TableA VALUES('A-One') INSERT INTO @TableA VALUES('A-Two') INSERT INTO @TableA VALUES('A-Three') INSERT INTO @TableB (A_ID, Description) VALUES(1,'B-One') INSERT INTO @TableB (A_ID, Description) VALUES(1,'B-Two') INSERT INTO @TableB (A_ID, Description) VALUES(1,'B-Three') INSERT INTO @TableB (A_ID, Description) VALUES(2,'B-Four') INSERT INTO @TableB (A_ID, Description) VALUES(2,'B-Five') INSERT INTO @TableB (A_ID, Description) VALUES(3,'B-Six') INSERT INTO @TableC VALUES('C-One') INSERT INTO @TableC VALUES('C-Two') INSERT INTO @TableC VALUES('C-Three') INSERT INTO @TableB_C (B_ID, C_ID) VALUES(1, 1) INSERT INTO @TableB_C (B_ID, C_ID) VALUES(2, 1) INSERT INTO @TableB_C (B_ID, C_ID) VALUES(3, 1) -------------------------------------------------------------------------------------------- -- Get result - method 1 -------------------------------------------------------------------------------------------- SELECT TOP 1 C.*, A.Description FROM @TableC C JOIN @TableB_C BC ON BC.C_ID = C.C_ID JOIN @TableB B ON B.B_ID = BC.B_ID JOIN @TableA A ON B.A_ID = A.A_ID WHERE C.C_ID = 1 -------------------------------------------------------------------------------------------- -- Get result - method 2 -------------------------------------------------------------------------------------------- SELECT C.*, (SELECT A.Description FROM @TableA A WHERE EXISTS (SELECT * FROM @TableB_C BC JOIN @TableB B ON B.B_ID = BC.B_ID WHERE BC.C_ID = C.C_ID AND B.A_ID = A.A_ID)) FROM @TableC C WHERE C.C_ID = 1

    Read the article

  • Length of a string in pixels

    - by Rose
    Guys, I'm populating a dropDownList with arrayCollection of strings. I want the width of the drop down list control to match with the size (in pixels) of the longest string in the array collection. The problem I'm facing is: the font width of the strings in the collection are different e.g. 'W' looks wider than 'l'. So I estimated the width of a character to be 8 pixels but that's not pretty neat. If a string that has many 'W' and 'M' is encountered the estimation is wrong. So I want precise pixel width of strings. How can i get the exact length of a string in pixels?? My solution that estimates all character to be 8 pixels wide is given below: public function populateDropDownList():void{ var array:Array = new Array("o","two","three four five six seven eight wwww"); var sampleArrayCollection:ArrayCollection = new ArrayCollection(array); var customDropDownList:DropDownList = new DropDownList(); customDropDownList.dataProvider=sampleArrayCollection; customDropDownList.prompt="Select ..."; customDropDownList.labelField="Answer Options:"; //calculating the max width var componentWidth=10; //default for each(var answerText in array){ Alert.show("Txt size: "+ answerText.length + " pixels: " + answerText.length*9); if(answerText.length * 8 > componentWidth){ componentWidth=answerText.length * 8; } } customDropDownList.width=componentWidth; answers.addChild(customDropDownList); } Any idea or solution is highly valued. Thanks

    Read the article

  • Creating transparent PNG with exact RGBA values

    - by rrowland
    I'm color-coding a transparent image to be read programatically. However, the image seems to be getting compressed and my code is reading color values other than the ones I mean to pass it. Concept This is the output I get, exporting as PNG-24. I programatically check each pixel for one of the six colors I use in creating the image: 0x00000F 0x0000F0 0x000F00 0x00F000 0x0F0000 0xF00000 Each color represents a different texture to apply. Top right (0x00000F) will pull texture from the tile to its top right and blend it at a ratio equal to the opacity of the pixel. The end goal is to create a hex tiled grid with differing textures that blend smoothly. What's happening It seems that when converting to PNG, Photoshop will change the RGBA to make it smoother, or just to help compression size. Parts that should be 250 red range anywhere from 150 to 255. Question Whether using PNG or another web-compatible format, I need to be able to save these pixel values, essentially instructions, loss-less and still maintain transparency. Is this possible in any format or will I need to re-think my approach?

    Read the article

  • Core Data to-many relationship in code

    - by Jan Bezemer
    I have three entities: Session, User and Test. A session has 0-many users and a user can perform 0-6 tests. (I say 0 but in the real application always at least 1 is required, at least 1 user for a session and at least 1 test for a user. But I say 0 to express an empty start.) All entities have their own specific data attributes too. A user has a name, A session has a name, a test has six values to be filled in by the user, and so on. But my issue is with the relationships. How do I set multiple users and have them added to one session (same goes for multiple tests for one user). How do I show the content in a right way? How do I show a session that has multiple users and these users having completed multiple tests? Here's my code so far with regard to issue 1: Session *session = [NSEntityDescription insertNewObjectForEntityForName:@"Session" inManagedObjectContext:context]; session.name = @"Session 1"; User *users = [NSEntityDescription insertNewObjectForEntityForName:@"User" inManagedObjectContext:context]; users.age = [NSNumber numberWithInt:28]; users.session = session; //sessie.users = users; [sessie addUserObject:users]; With regard to issue 2: I can log the session, but I can't get the user(s) logged from a session. NSFetchRequest *fetchRequest = [[NSFetchRequest alloc] init]; NSEntityDescription *entity = [NSEntityDescription entityForName:@"Session" inManagedObjectContext:context]; [fetchRequest setEntity:entity]; NSArray *fetchedObjects = [context executeFetchRequest:fetchRequest error:&error]; for (Session *info in fetchedObjects) { NSLog(@"Name: %@", info.name); NSLog(@"Having problems with this: %@",info.user); //User *details = info.user; //NSLog(@"User: %@", details.age); }

    Read the article

  • SDK2 query for counting: which is more efficient?

    - by user1195996
    I have an app that is displaying metrics about defects in a project. I have the option of making one query that returns all the defects, and from that I can break out about four different metrics (How many defects escaped QA in 90 days, 180 days, and then the same metrics again but only counting sev1/sev2 defects). I could make four queries and limit the results to one so that I just get a count for each. Or I could make one query that encompass them all (all defects that escaped QA in 180 days) and then count up the difference. I'm figuring worst case, the number of defects that escaped QA in the last six months will generally be less than 100, certainly less 500 worst case. Which would you do-- four queryies with one result each, or one single query that on average might return 50, perhaps worst case 500? And I guess the key question is-- where are the inflections points? Perhaps I have more metrics tomorrow (who knows, 8?) and a different average defect counts. Is there a rule of thumb I could use to help choose which approach?

    Read the article

  • CentOS 5.5 : Postfix, Dovecot & MySQL

    - by GruffTech
    I'm hoping someone has seen this issue before because I'm at quite a loss. We're building a new outbound smtp server for our clients that features anti-spam scanning and virus scanning for outbound emails, something we had not previously done. So with CentOS 5.5 x64, Installed and patched completely. Postfix & Dovecot both installed via base repo. [grufftech@outgoing postfix]# rpm -qa | grep postfix postfix-2.3.3-2.1.el5_2 [grufftech@outgoing postfix]# rpm -qa | grep dovecot dovecot-1.0.7-7.el5 [grufftech@outgoing ~]# dovecot --build-options Build options: ioloop=poll notify=inotify ipv6 openssl SQL drivers: mysql postgresql Passdb: checkpassword ldap pam passwd passwd-file shadow sql Userdb: checkpassword ldap passwd prefetch passwd-file sql static /etc/dovecot.conf auth default { mechanisms = plain login digest-md5 cram-md5 passdb sql { args = /etc/dovecot-mysql.conf } userdb sql { args = /etc/dovecot-mysql.conf } userdb prefetch { } user = nobody socket listen { master { path = /var/run/dovecot/auth-master mode = 0660 user = postfix group = postfix } client { path = /var/spool/postfix/private/auth mode = 0660 user = postfix group = postfix } } } All the server is doing is auth for postfix, so no reason to have imap / pop / dict. /etc/dovecot-mysql.conf driver = mysql connect = host=10.0.32.159 dbname=mail user=****** password=******** default_pass_scheme = plain user_query = select 1 password_query = select password from users where username = '%n' and domain = '%d' So drop in my configuration, (which is working on another server identical to this one.) [grufftech@outgoing ~]# /etc/init.d/dovecot start Starting Dovecot Imap: [ OK ] Sweet. Booted up nicely, thats good.... (incoming problem in 3....2....1....) May 21 08:09:01 outgoing dovecot: Dovecot v1.0.7 starting up May 21 08:09:02 outgoing dovecot: auth-worker(default): mysql: Connect failed to 10.0.32.159 (mail): Can't connect to MySQL server on '10.0.32.159' (13) - waiting for 1 seconds before retry well what the crap. went and checked permissions on my MySQL database, and its fine. [grufftech@outgoing ~]# mysql vpopmail -h 10.0.32.159 -u ****** -p Enter password: Welcome to the MySQL monitor. Commands end with ; or \g. Your MySQL connection id is 127828558 Server version: 4.1.22 Type 'help;' or '\h' for help. Type '\c' to clear the buffer. mysql>\q So! My server can talk to my database server. but dovecot, for whatever reason, isn't able to. I've fiddled with it for the last six hours, grabbed slightly-older copies of the RPM (ones that matched our production server exactly) to test those, copied configs, searched google, searched server fault, chatted in IRC, banged my head against the table, I've done it all. Surely I'm doing something wrong or forgetting something, can anyone tell me what the elephant in the room is? This stuff is supposed to work.

    Read the article

  • Windows 7 is shutting down unexpectedly, according to the logs.

    - by dlamblin
    Here's a message from my eventvwr EventLog (Windows Logs System): The previous system shutdown at 11:51:15 AM on ?7/?29/?2009 was unexpected. This is funny because I was wondering why the system shut down while I was playing Civilizations IV full screen. Now I know. It was unexpected. Has anyone encountered and resolved this? A little background: I am running Windows 7 RC inside VMWare Fusion 2 (just updated a few months back) on a MacBook (Bitterly not Pro) aluminum-body. Windows 7 occasionally will shut down. This isn't a quick turn-off, it's a shutdown where all the programs are exited, the system waits until they quit (and Civ4 doesn't prompt me to save), it even installed Windows Updates before restarting. And yes it is restarting right after the shutdown. Because I run a game in full screen mode I do not notice any dialog with a countdown timer or anything like that that might be a warning. As I have iStat on my dashboard widgets I can see about 8 temperature monitors. I have seen the CPU get up to 74C before, but during the shutdown, though it seemed hot to the touch (always is), it read 61C for the CPU, 60C for heatsink A, 50C for heatsink B and in the 30s-40s for the enclosure and harddrives. As I type this now, the temps are actually higher, so I don't think the temperature caused it. I have at least six such events dating first from 5/17 which was a week after installing Windows 7. I did find one information level warning from USER32 in the system log that says: The process C:\Windows\system32\svchost.exe (DLAMBLIN-WIN7) has initiated the restart of computer DLAMBLIN-WIN7 on behalf of user NT AUTHORITY\SYSTEM for the following reason: Operating System: Recovery (Planned) Reason Code: 0x80020002 Shutdown Type: restart Comment: And another 15 minutes before that from Windows Update: Restart Required: To complete the installation of the following updates, the computer will be restarted within 15 minutes: - Cumulative Security Update for Internet Explorer 8 for Windows 7 Release Candidate for x64-based Systems (KB972260) Which I think kind of explains it. Though I don't know why restarting after an update would create an error event of "shutdown was unexpected", isn't that pretty odd? Now, how do I set it to never restart after an update unless I click something. Application of solution: As fretje reminded me, there's a couple of configurable settings for this, in windows 7 they're much in the same place as in Windows 2000 SP3 and XP SP1. Running gpedit.msc pops up a window that looks like: Windows 7 has changed the order and added a couple of newer options I've italicized: Do not display 'Install Updates and Shut Down' in Shut Down Windows dialog box Do not adjust default option to 'Install Updates and Shut Down' in Shut Down Windows dialog box Enabling Windows Power Management to automatically wake up the system to install scheduled updates Configure Automatic Updates Specify intranet Microsoft update service location Automatic Updates detection frequency Allow non-administrators to receive update notifications Turn on Software Notifications Allow Automatic Updates immediate installation Turn on recommended updates via Automatic Updates No auto-restart with logged-on users for scheduled Automatic Updates Re-prompt for restart with scheduled installations. Delay Restart for scheduled installations Reschedule Automatic Updates schedule

    Read the article

  • Unix sort keys cause performance problems

    - by KenFar
    My data: It's a 71 MB file with 1.5 million rows. It has 6 fields All six fields combine to form a unique key - so that's what I need to sort on. Sort statement: sort -t ',' -k1,1 -k2,2 -k3,3 -k4,4 -k5,5 -k6,6 -o output.csv input.csv The problem: If I sort without keys, it takes 30 seconds. If I sort with keys, it takes 660 seconds. I need to sort with keys to keep this generic and useful for other files that have non-key fields as well. The 30 second timing is fine, but the 660 is a killer. More details using unix time: sort input.csv -o output.csv = 28 seconds sort -t ',' -k1 input.csv -o output.csv = 28 seconds sort -t ',' -k1,1 input.csv -o output.csv = 64 seconds sort -t ',' -k1,1 -k2,2 input.csv -o output.csv = 194 seconds sort -t ',' -k1,1 -k2,2 -k3,3 input.csv -o output.csv = 328 seconds sort -t ',' -k1,1 -k2,2 -k3,3 -k4,4 input.csv -o output.csv = 483 seconds sort -t ',' -k1,1 -k2,2 -k3,3 -k4,4 -k5,5 input.csv -o output.csv = 561 seconds sort -t ',' -k1,1 -k2,2 -k3,3 -k4,4 -k5,5 -k6,6 input.csv -o output.csv = 660 seconds I could theoretically move the temp directory to SSD, and/or split the file into 4 parts, sort them separately (in parallel) then merge the results, etc. But I'm hoping for something simpler since looks like sort is just picking a bad algorithm. Any suggestions? Testing Improvements using buffer-size: With 2 keys I got a 5% improvement with 8, 20, 24 MB and best performance of 8% improvement with 16MB, but 6% worse with 128MB With 6 keys I got a 5% improvement with 8, 20, 24 MB and best performance of 9% improvement with 16MB. Testing improvements using dictionary order (just 1 run each): sort -d --buffer-size=8M -t ',' -k1,1 -k2,2 input.csv -o output.csv = 235 seconds (21% worse) sort -d --buffer-size=8M -t ',' -k1,1 -k2,2 input.csv -o ouput.csv = 232 seconds (21% worse) conclusion: it makes sense that this would slow the process down, not useful Testing with different file system on SSD - I can't do this on this server now. Testing with code to consolidate adjacent keys: def consolidate_keys(key_fields, key_types): """ Inputs: - key_fields - a list of numbers in quotes: ['1','2','3'] - key_types - a list of types of the key_fields: ['integer','string','integer'] Outputs: - key_fields - a consolidated list: ['1,2','3'] - key_types - a list of types of the consolidated list: ['string','integer'] """ assert(len(key_fields) == len(key_types)) def get_min(val): vals = val.split(',') assert(len(vals) <= 2) return vals[0] def get_max(val): vals = val.split(',') assert(len(vals) <= 2) return vals[len(vals)-1] i = 0 while True: try: if ( (int(get_max(key_fields[i])) + 1) == int(key_fields[i+1]) and key_types[i] == key_types[i+1]): key_fields[i] = '%s,%s' % (get_min(key_fields[i]), key_fields[i+1]) key_types[i] = key_types[i] key_fields.pop(i+1) key_types.pop(i+1) continue i = i+1 except IndexError: break # last entry return key_fields, key_types While this code is just a work-around that'll only apply to cases in which I've got a contiguous set of keys - it speeds up the code by 95% in my worst case scenario.

    Read the article

  • Sendmail - Multiple Domains, One Box - Blocking One Or Two Domains

    - by TangoOversway
    I have a number of domains hosted at a web hosting service. They use sendmail to handle incoming email. I have six domains on this service (which we can call aaa.com, bbb.com and so on). Each email account has the same name and one email box. In other words, [email protected], [email protected], [email protected] and all the others go into one box, /var/spool/mail/tango, where my email program on my desktop picks it up. I have done very little work in sendmail. I haven't had to, and I've been warned it's a steep learning curve. But now I'm running into an issue. I was in a business situation where, for years, my email address was on the website for aaa.com. (We won't go into why this was necessary - it wasn't my preference and it's in the past.) Now I'm using [email protected] instead of [email protected]. I was getting about 1,000 or more pieces of spam a day, but SpamAssassin and my own email program caught about 75% of that. (Which still left stuff to delete.) Now, after checking, I see that 90% or more goes to [email protected], the one that was on the web for years. I'd like to deactivate [email protected] and possibly [email protected] and [email protected], but want to keep using [email protected]. Remember, email to tango at any of these domains will go into one email box. I've had people tell me that sendmail can be configured so I can deactivate [email protected] (and other domains) and still use [email protected] (and others, if I want to). In other words, I can configure sendmail to use this account on some domains and not others. One of the people who was teling me this was in tech support at the hosting service. But I wrote to tech support with a work order to do this and now I'm told it can't be done. I can modify config files myself on this account if needed, but I was hoping to just let them do it. (I love delegation -- it means I spend more time doing my stuff.) Is it possible to keep an email account active on one domain and not others with sendmail, when all domains are hosted on the same server? Is there a name for this process or setting? Any information would be helpful - either pointers to instructions so I can do it, or enough info so I can tell tech support, "This is where to look, and it can be done, so please pass my request on to someone who works with sendmail and knows how to do it." Is this something sendmail can do?

    Read the article

  • WSUS appears to be functioning, however errors are reported in Application Log (DSS Authentication W

    - by Richard Slater
    I re-installed WSUS a few months ago on a new server as part of a server hardware refresh. It is functioning normally downloading, authorizing and supplying patches to workstations. System Specification: HP DL360 G5 Quad 2.5 Zeon 6GB RAM Not Virtualized WSUS 3.2.7600.3226 SQL 2005 Express Windows 2003 R2 SP2 WSS SSL Enabled Every six hours five events are logged to the Application Event Log: Source | Category | ID | Description -------------------------------------------------------------------------------------- Windows Server Update Services | Web Services | 12052 | The DSS Authentication Web Service is not working. Windows Server Update Services | Web Services | 12042 | The SimpleAuth Web Service is not working Windows Server Update Services | Web Services | 12022 | The Client Web Service is not working Windows Server Update Services | Web Services | 12032 | The Server Synchronization Web Service is not working Windows Server Update Services | Web Services | 12012 | The API Remoting Web Service is not working In addition the following .NET Stack Trace is logged in C:\Program Files\Update Services\LogFiles\SoftwareDistribution.log each stack trace is identical except for the names of the services: 2009-11-27 11:56:52.757 UTC Error WsusService.10 HmtWebServices.CheckApiRemotingWebService ApiRemoting WebService WebException:System.Net.WebException: The request failed with HTTP status 403: Forbidden. at System.Web.Services.Protocols.SoapHttpClientProtocol.ReadResponse(SoapClientMessage message, WebResponse response, Stream responseStream, Boolean asyncCall) at System.Web.Services.Protocols.SoapHttpClientProtocol.Invoke(String methodName, Object[] parameters) at Microsoft.UpdateServices.Internal.ApiRemoting.Ping(Int32 pingLevel) at Microsoft.UpdateServices.Internal.HealthMonitoring.HmtWebServices.CheckApiRemotingWebService(EventLoggingType type, HealthEventLogger logger) at Microsoft.UpdateServices.Internal.HealthMonitoring.HmtWebServices.CheckApiRemotingWebService(EventLoggingType type, HealthEventLogger logger) at Microsoft.UpdateServices.Internal.HealthMonitoring.HealthMonitoringTasks.ExecuteSubtask(HealthMonitoringSubtask subtask, EventLoggingType type, HealthEventLogger logger) at Microsoft.UpdateServices.Internal.HealthMonitoring.HmtWebServices.Execute(EventLoggingType type) at Microsoft.UpdateServices.Internal.HealthMonitoring.HealthMonitoringTasks.Execute(EventLoggingType type) at Microsoft.UpdateServices.Internal.HealthMonitoring.HealthMonitoringThreadManager.Execute(Boolean waitIfNecessary, EventLoggingType loggingType) at Microsoft.UpdateServices.Internal.HealthMonitoring.RemotingChannel.PrivateLogEvents() at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Int32 methodPtr, Boolean fExecuteInContext, Object[]& outArgs) at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg, Int32 methodPtr, Boolean fExecuteInContext) at System.Runtime.Remoting.Messaging.ServerObjectTerminatorSink.SyncProcessMessage(IMessage reqMsg) at System.Runtime.Remoting.Lifetime.LeaseSink.SyncProcessMessage(IMessage msg) at System.Runtime.Remoting.Messaging.ServerContextTerminatorSink.SyncProcessMessage(IMessage reqMsg) at System.Runtime.Remoting.Channels.CrossContextChannel.SyncProcessMessageCallback(Object[] args) at System.Runtime.Remoting.Channels.ChannelServices.DispatchMessage(IServerChannelSinkStack sinkStack, IMessage msg, IMessage& replyMsg) at System.Runtime.Remoting.Channels.SoapServerFormatterSink.ProcessMessage(IServerChannelSinkStack sinkStack, IMessage requestMsg, ITransportHeaders requestHeaders, Stream requestStream, IMessage& responseMsg, ITransportHeaders& responseHeaders, Stream& responseStream) at System.Runtime.Remoting.Channels.BinaryServerFormatterSink.ProcessMessage(IServerChannelSinkStack sinkStack, IMessage requestMsg, ITransportHeaders requestHeaders, Stream requestStream, IMessage& responseMsg, ITransportHeaders& responseHeaders, Stream& responseStream) at System.Runtime.Remoting.Channels.Ipc.IpcServerTransportSink.ServiceRequest(Object state) at System.Runtime.Remoting.Channels.SocketHandler.ProcessRequestNow() at System.Runtime.Remoting.Channels.SocketHandler.BeginReadMessageCallback(IAsyncResult ar) at System.Runtime.Remoting.Channels.Ipc.IpcPort.AsyncFSCallback(UInt32 errorCode, UInt32 numBytes, NativeOverlapped* pOverlapped) at System.Threading._IOCompletionCallback.PerformIOCompletionCallback(UInt32 errorCode, UInt32 numBytes, NativeOverlapped* pOVERLAP) So far I have tried the following: Ensuring the settings were accurate as per TechNet. Checked that there was a suitable binding to 127.0.0.1 binding in IIS. Gone through and checked the settings in IIS as per TechNet. I have discovered that you can run the command wsusutil checkhealth to force the healt check to run, wsusutil can be found in C:\Program Files\Update Services\Tools. When this executese it will tell you to check the application log.

    Read the article

  • Disk performance below expectations

    - by paulH
    this is a follow-up to a previous question that I asked (Two servers with inconsistent disk speed). I have a PowerEdge R510 server with a PERC H700 integrated RAID controller (call this Server B) that was built using eight disks with 3Gb/s bandwidth that I was comparing with an almost identical server (call this Server A) that was built using four disks with 6Gb/s bandwidth. Server A had much better I/O rates than Server B. Once I discovered the difference with the disks, I had Server A rebuilt with faster 6Gbps disks. Unfortunately this resulted in no increase in the performance of the disks. Expecting that there must be some other configuration difference between the servers, we took the 6Gbps disks out of Server A and put them in Server B. This also resulted in no increase in the performance of the disks. We now have two identical servers built, with the exception that one is built with six 6Gbps disks and the other with eight 3Gbps disks, and the I/O rates of the disks is pretty much identical. This suggests that there is some bottleneck other than the disks, but I cannot understand how Server B originally had better I/O that has subsequently been 'lost'. Comparative I/O information below, as measured by SQLIO. The same parameters were used for each test. It's not the actual numbers that are significant but rather the variations between systems. In each case D: is a 2 disk RAID 1 volume, and E: is a 4 disk RAID 10 volume (apart from the original Server A, where E: was a 2 disk RAID 0 volume). Server A (original setup with 6Gpbs disks) D: Read (MB/s) 63 MB/s D: Write (MB/s) 170 MB/s E: Read (MB/s) 68 MB/s E: Write (MB/s) 320 MB/s Server B (original setup with 3Gpbs disks) D: Read (MB/s) 52 MB/s D: Write (MB/s) 88 MB/s E: Read (MB/s) 112 MB/s E: Write (MB/s) 130 MB/s Server A (new setup with 3Gpbs disks) D: Read (MB/s) 55 MB/s D: Write (MB/s) 85 MB/s E: Read (MB/s) 67 MB/s E: Write (MB/s) 180 MB/s Server B (new setup with 6Gpbs disks) D: Read (MB/s) 61 MB/s D: Write (MB/s) 95 MB/s E: Read (MB/s) 69 MB/s E: Write (MB/s) 180 MB/s Can anybody suggest any ideas what is going on here? The drives in use are as follows: Dell Seagate F617N ST3300657SS 300GB 15K RPM SAS Dell Hitachi HUS156030VLS600 300GB 3.5 inch 15000rpm 6GB SAS Hitachi Hus153030vls300 300GB Server SAS Dell ST3146855SS Seagate 3.5 inch 146GB 15K SAS

    Read the article

  • VMWare Network bug in multiple VMWare Workstation versions if using a hardcoded IP address

    - by onyxruby
    I'm having a very tricky problem with some of my VM sessions being unable to reach the Internet or even ping the gateway. I have just set up a new VM Workstation (7) on a W2K8 64bit server (I'll be converting to ESXI 4 once I can find a decent book on it, so for the meanwhile I use workstation). I have imported a number of VM's and setup some new ones on the server.In short the problem with some of the VM's being unable to reach the Internet is that they can't reach the gateway. I've looking at a number of things and can pretty safely rule out the following: Switch, Router, DHCP Server, DNS, Client IP configuration, Routes and typos. The problem is that some of the new clients cannot reach the gateway if their IP address is hardcoded, they can't even ping it by IP address. That rules out DNS and DHCP. Now, if I allow them to get their IP address by DHCP they can reach the gateway and Internet without issue. The interesting thing on this, is that this behavior occurs even if I leave the DNS information hardcoded under TCP/IP settings. It doesn't work unless the IP and gateway are handed out by DHCP even though the same information IP info is being used by the host. Fundamentally from the standpoint of the clients, they are trying to reach the exact same gateway using the exact same IP information regardless of whether they are hardcoded or assigned by DHCP. Here's an example of one client. IP Address 192.168.7.66 - Subnet Mask 255.255.255.0 - Gateway 192.168.7.254 - DNS1 192.168.7.44 - DNS2 192.168.7.254. The issue occurs across six different microsoft operating systems, Windows 7 and Windows 2008 variants all have the issue. My W2K3, XP, Vista and W98 clients all work without issue with hardcoded IP addresses. I have tried things like rearranging the DNS order, flushing DNS and so on. It's not a routing or switch issue as the clients can work just fine if they get their IP by DHCP. It's not a paramater issue as the exact same paramaters are handed out by DHCP as I plug in by hand. It's not a DNS issue as clients cant reach other clients even with IP addresses only. I have run a tracert to the gateway by IP address and it times out on the very first hop before failing on hop3 with destination host unreachable. If I get the IP address by DHCP the tracert finds the gateway (and Internet) without issue. I have read a few other posts online in forums talking about this problem randomly occuring over the years in other VM versions as well, so I suspect some kind of long standing bug. Does anyone have any ideas on this? Is it possibly a bug with Windows 7 and W2K clients under VM?

    Read the article

  • Determining the health of a Cisco switch port?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced recently, however, the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link. We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • OpenVPN, Great on Windows, VERY slow on Mac...

    - by Phsion
    Hello, I'm not really an IT Pro, but this seemed like the best place to ask this question... I have setup VPN networks in the past, for fun, and everything was great, but now I've set one up for my boss, and while my computers all work great, his Mac machines are almost too slow to work with. Its pretty much vanilla configs all around, anyone have any ideas? Its a TUN routing setup over UDP. Back Story: My boss travels a lot, and wants to be able to access all his files from the road, and is also pretty paranoid about security (even though knows almost nothing about computers). SO i figured a VPN would be the answer. I went with OpenVPN, but there are some other issues. The only ISP we can get in our area besides Dial-UP is a crappy Satellite provider, that doesn't offer public IPs unless your willing to pay, so while the computers and VPN setup are pretty vanilla, the routing and structure is strange to get around this limitation. Specs: Its OpenVPN2, and there are six machines using it (only three actually use it, the rest are my test machines), one Windows 7 laptop, two XP Desktops, one OS X 10.5 Desktop, one 10.6 Desktop, and one 10.6 Laptop. One XP Desktop sits at my house and acts as the server (6Mbs/2Mbs FIOS connection). One XP desktop sits at the office and hosts a webpage that will wake up the Main Mac Desktop from sleep, and also ping all the machines on the VPN and show their status. The main office mac (10.6) stays in sleep mode until it gets the Wake-On-Lan packet from the Office XP, and then it auto connects to the VPN and opens itself up. The reason for all this is the Satellite private IP crap means i cant directly access the office machines outside of the LAN, so everyone connects to my house first, then they talk to each other from there. The Wake On Lan weirdness is because my boss doesn't want to leave the main Mac on all the time, and making a quick and dirty webpage was the easiest way to send a Magic Packet from inside the LAN without confusing my boss. The VPN uses Client Config files to make static IPs for the client. The only thing i found in google was some changes to the VPN MTU settings (down to 1400) but no real help. Oh, and i forgot...all the windows machines just have OpenVPN start as a service. The Mac laptop uses tunnelblick (an OpenVPN GUI) and the Mac Desktops use OpenVPN in normal command line mode. Server Config: tun-mtu 1500 fragment 1450 mssfix 1450 management localhost #### port #### proto udp dev tun ca ####### cert ####### key ###### dh ###### server 10.8.0.0 255.255.255.0 ifconfig-pool-persist ipp.txt client-config-dir ccd route 10.8.0.0 255.255.255.252 client-to-client keepalive 10 120 comp-lzo persist-key persist-tun status openvpn-status log Client Configs (all are simple variations on this) tun-mtu 1500 fragment 1450 mssfix 1450 client dev tun proto udp remote ######## #### resolv-retry infinite nobind persist-key presist-tun ca ##### cert ##### key ##### ns-cert-type server comp-lzo verb 3

    Read the article

  • Splitting an internet connection between multiple separate subnetworks

    - by pythonian4000
    Problem I have an internet connection that I want to split between four separate networks. My requirements are: I need to be able to monitor the amount of bandwidth and data being used by each network, and notify or control as necessary. The four networks should only be able to connect to the internet, not each other. My parents need to be able to operate it, so it needs a simple, preferably Windows-based GUI. Progress so far Server I have a mini-ITX server with six Gigabit ethernet ports - one for the ethernet internet connection, one for each of the four networks, and one for remote access to the server for administration. Bandwidth control I spent a long time researching solutions here. The majority of the control systems/software I found could control bandwidth usage via QOS, but could not monitor or control the amount of data being used. Eventually I found the SoftPerfect Bandwidth Manager, which has everything I need in terms of monitoring and control - per-interface quota management, usage statistics, a web interface for checking usage, and email notifications when quotas are exceeded. It is also Windows-based and has a simple GUI. Internet sharing This is where I am having issues. I am currently using Windows XP Pro SP2 for the server (yes, I know this is far from ideal, but it's the only spare Windows OS I currently have). I can't use the built-in Internet Connection Sharing for several reasons: The upstream internet router has an IP of 192.168.0.1 which ICS clashes with, and I cannot change the router settings. ICS can only share an internet connection with a single interface, but I have four. I have tried bridging the four network cards, but then the Bandwidth Manager cannot see the four individual interfaces - it only sees the bridge. I have tried setting up Dual DHCP DNS server (and am having issues getting DHCP offers to be received by clients), but that would still require gateway software of some sort, which I have been unable to find. My current attempt is to use OpenVPN, with a server for the internet NIC and a separate client for each of the four networks. My thought is that I could bridge the OpenVPN TAP devices to each NIC, meaning that the Bandwidth Manager would control traffic from the bridge instead of the interface. I have not made much progress here though - I've never used OpenVPN before. Questions Is there a Windows software package that does everything I need? (Unlikely, I know) Is there a Windows software package that will share internet between multiple NICs without bridging? Are either of my about attempts feasible? Would it help to have a newer/server version of Windows? Is there a non-Windows alternative that is easy to use?

    Read the article

  • Critique My Backup and Storage Plan

    - by MetaHyperBolic
    My current storage (RAID-1 off of a hardware RAID card) and backup (a spare drive) solutions for my home network are inadequate. I have too much data scattered on various one-off drives. It is time to evolve. Backups seem simple enough, at least: lots of big drives. However, I am bewildered by the number of choices for small home storage. The Drobo S looks appealing. So does the ReadyNAS. I am not looking for bunches of shiny features, I'm mostly interested in reliability. I am not interested in building Yet Another PC to create a file server or doing something in the cloud, or whatever. I'm stupid, so I am keeping it simple. Requirements for Main Volume: Starting working space roughly 2TB, with options for growth up to 5TB RAID or something RAID-like with at least one parity drive eSATA II for speed during backups Ability to shut down gracefully when alerted of low power by a UPS Optional but Desirable: Will take 2TB drives now with options for the larger 3TB drives coming in 2010-2011 Optional but Desirable: : RAID-6 or something similar, with two parity drives Optional but Desirable: : Hot spare Ethernet connection not required, as the volume will be shared via the same machines which runs my home print server Backups: Backup performed via ROBOCOPY in mirror mode to an external hard drive via a eSATA II connection. Start with rotating between two external 2TB hard drives, will go up to six external 2TB drives. Start with a weekly backup, move to a bi-weekly backup as more drives are added. Move to 3TB drives as the size of my main volume increases. Backup drives will be stored on an off-site location. Hard drives: I plan on buying all of the same model, but different batches from different vendors. I found a "burn-in" utility with which I can pound away on the drives for a couple of weeks before adding them to the backup pool or the main volume. I estimate that I am looking at roughly $1,500 to start, once I start throwing in two TB drives for backup and four for storage. So, are there any obvious flaws in my plan? What have I overlooked? Any suggestions for the storage device for my main volume that fits my requirements? Or do I just keep it simple, 2 drives in RAID-1, then perform due diligence with my backups, accepting that I will have to buy a whole new unit when my data grows past 2TB?

    Read the article

  • Windows 7 laptop constantly dropping internet connection

    - by Corbin Holbert
    I have scoured the web for an answer and failed to find one. I am using a Toshiba Satellite laptop running Windows 7 64-Bit. I have the computer connected via Wifi. Now, I am no beginner with the Internet, or anything related to computers, as I have grown up teaching everyone around me how to use computers, and went to college for IT. Everything on my network works flawlessly at all times, except for this evil laptop. The worst part is that I fixed this once before a few years back and recently had to replace the hard drive and re-install the OS, but cannot for the life of me remember what I did to make this problem go away. I am in my browser, connected to the Internet. I click a link. Suddenly no internet access. All I do is click down on the WiFi connection in the task bar, disconnect and reconnect immediately. Internet is back the moment I hit "connect." I have read many people had the same issues as I am having, but they all had triggers or other network issues. I have no trigger (this happens literally five to six times per minute no matter what I am doing) and I have no problems with my router, modem, or any other devices or computers on said network. As I am a web designer, and like to test my work live at every turn- this is going to result in this laptop being in pieces if I can't get it fixed soon. If more info is needed, let me know and I will provide. Thanks for any help offered! EDIT: Network Card: Realtek RTL8188CE Wireless LAN 802.11n PCI-E NIC Network state reads as "No Internet Access" when the problem first occurs, then magically I have Internet access for about ten seconds once I disconnect and reconnect. I have turned off IPV6, I have turned off power saving options for the network adapter, no viruses. Any new ideas? Also, I had to disconnect and reconnect four times just to get to this edit screen- and will likely have to do the same just to post it- it's that bad.

    Read the article

  • Gigabyte GA-970A-UD3 mobo won't boot from USB flash drive

    - by user38586
    I am trying to boot BAMT a Debian flavor via USB on a brand new Gigabyte GA-970A-UD3 motherboard. I tried various flash drive and various OS. I never had this problem with ASUS and MSI. The problem is from Gigabyte hardware. I found that my BIOS is very strict about MBR compatibility. Now I can boot in DOS mode. The flash drive need to be formated as a Win98 Startup disk using HP USB disk storage format tool. Unetbootin menu is booting from USB but won't install BAMT. If I use Windows or Linux diskimager the working MBR is deleted. I tried converting BAMT .img to .iso and it is not booting with Unetbootin. Is it possible to boot BAMT(Debian Linux) from a Win98 DOS command prompt? Maybe there is a way to burn the image and keep the working MBR? If the working MBR is deleted, the flash drive is not recognized at all by the BIOS. This is the info I found that got me booting for the first time in DOS: GB's BIOS will only boot USBs formatted to FAT-32, conforming to normal MBR bootloader. I've seen this before, and surmised that the 'stick-maker' was formatting in ReiserFile, or one of the EXT 'flavors', but no one ever followed up to confirm or deny... Also, if it's putting the bootloader into its own partition - won't work! In the BIOS, on the "Integrated Peripherals" page, the "USB Storage Function" item must be enabled (which should be the default) to allow USB booting... I've put a little work into a 'GB USB booting tutorial', and frankly, I'd just go ahead and finish it up for you, but I really don't want to reboot the several times it will take me to 'firm up' procedural details, and take the BIOS/boot pictures for the post - just noticed VAIL finally went 'public beta', so will be downloading for likely twenty-six hours or so There's likely enough there to test a 'raw DOS boot', just to see if your hardware (especially the USB stick itself) will do it... Some post later: Fixed. Here is a brief summary. Since my ubuntu live usb sticks (2gb kingston and 8gb sandisk sd/usb reader - fat32, created in ubuntu 10.04) would not boot this board even though they would boot my ga-ep45-ud3p, I decided to try bilbat's suggestion with the HP usb boot program. I created the win98 boot disk on the kingston 2gb stick without reformatting. It booted right up. Next, I used windows version of unetbootin to write the ubuntu live cd to the kingston disk. This fired right up and completed the install. Everything seems to be in good order now. Unfortunately I can boot in DOS mode but can't boot BAMT.

    Read the article

  • Exchange 2007 and migrating only some users under a shared domain name

    - by DomoDomo
    I'm in the process of moving two law firms to hosted Exchange 2007, a service that the consulting company I work for offers. Let's call these two firms Crane Law and Poole Law. These two firms were ONE firm just six months ago, but split. So they have three email domains: Old Firm: craneandpoole.com New Firm 1: cranelaw.com New Firm 2: poolelaw.com Both Firm 1 & Firm 2 use craneandpoole.com email addresses, as for the other two domains, only people who work at the respective firm use that firm's domain name, natch. Currently these two firms are still using the same pre-split internal Exchange 2007 server, where MX records for all three domains point. Here's the problem. I'm not moving both companies at the same time. I'm moving Crane Law two weeks before Poole Law. During this two weeks, both companies need to be able to: Continue to receive emails addressed to craneandpoole.com Send emails between firms, using cranelaw.com and poolelaw.com accounts I also have a third problem: I'd like to setup all three domains in my hosting infrastructure way ahead of time, to make my own life easier What would solve all my problems would be, if there is some way I can tell Exchange 2007, even though this domain exists locally forward on the message to the outside world using public MX record as a basis for where to send it (or if I could somehow create a route for it statically that would work too). If this doesn't work, to address points #1 when I migrate Crane Law, I will delete all references locally to cranelaw.com on their current Exchange server, and setup individual forwards for each of their craneandpool.com mailboxes to forward to our hosted exchange server. This will also take care of point #2, since the cranelaw.com won't be there locally, when poolelaw.com tries to send to cranelaw.com, public MX records will be used for mail routing decisions and go to my hosted exchange. The bummer of that though is, I won't be able to setup poolelaw.com ahead of time in hosted Exchange, will have to wait to do it day of :( Sorry for the long and confusing post. Just wondering if there is a better or simpler way to do what I want? Three tier forests and that kind of thing are out, this is just a two week window where they won't be in the same place.

    Read the article

  • Problems when trying to connect to a router wirelessly

    - by Ruud Lenders
    The situation - At my girlfriend's parents' place there are six Windows 7 devices that are wired or wireless connected to a router: 3 dekstops and 3 laptops. There are also several smartphones using the router. The router is secured with WPA2 (AES). The problem - We never had any problems with the router for over a year. But recently - about 3 weeks ago - my girlfriend's laptop (HP) and my laptop (ASUS) started to develop problems while trying to connect to the router. The router has stopped showing up from the network list. Sometimes it comes back and shows up, but then it keeps saying something along the lines of "Could not connect", and not long after that it dissapears again. The range of the router is not the problem here, because we experience the same when we sit next to the router. Sometimes, if we are lucky, and waited a long time (10-15 minutes) without using the laptop for anything, the laptop will eventually succesful connect to the router. The attempts - Of course, the Window 7 troubleshooter. We tried troubleshooting the connection problems and the wireless network adapter, but no luck. We also reset the router enough times to know that's not helping either. Here's the full list of things we tried, but did not help: Running the Windows 7 troubleshooter Resetting the router (more than once) Setting the router settings to factory defaults Disconnecting all other devices except one laptop Applying a system restore Trying static/dynamic IP/DNS - Dynamic is better, right? Enabling/disabling IPv6 - Should I keep IPv6 disabled? Running the command: netsh wlan stop hostednetwork Running the command: netsh wlan set hostednetwork mode=disallow Updating/reïnstalling wireless adapter drivers The tests - To help finding the core of the problem, we tested the following: Plugging an ethernet cable in the router and in our laptops - worked fine Connecting someone else's laptop to the router (wireless) - worked fine Connecting our laptops to someone else's router - worked fine The router - This information might be relevant: Router model: Sitecom 300N Wireless Router Router hardware: version 01 The DCHP Server's IPs range from 192.168.0.100 to 192.168.0.200. Router settings: Wireless channel: 12 Channel bandwidth: 20/40 MHz Extension channel: 8 Preamble type: Long 802.11g protection: Disabled UPnP: Enabled The laptops - If you are wondering about our laptops: My laptop model: ASUS Pro64JQ Girlfriend's laptop: HP Pavillion G6 OS: Both Windows 7 Professional x64 - with Service Pack 1 My wireless adapter: Atheros AR9285 AdHoc 11n: Enabled The question - Does anyone have experienced the same problems as I do? Or does someone know how to solve this? Are there more tricks I can try, or settings I should change? Note - Our laptops are not slow or old. My laptop is 1.5 years old, and the other laptop is just 5 months old. I know how to keep laptops clean and I'm pretty sure both laptops are not bloated with useless software.

    Read the article

  • Is my Cisco switch port bad?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced last week, however the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link (switchport configuration pastebin). We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • Simple mdadm RAID 1 not activating spare

    - by Nick Liu
    I had created two 2TB HDD partitions (/dev/sdb1 and /dev/sdc1) in a RAID 1 array called /dev/md0 using mdadm on Ubuntu 12.04 LTS Precise Pangolin. The command sudo mdadm --detail /dev/md0 used to indicate both drives as active sync. Then, for testing, I failed /dev/sdb1, removed it, then added it again with the command sudo mdadm /dev/md0 --add /dev/sdb1 watch cat /proc/mdstat showed a progress bar of the array rebuilding, but I wouldn't spend hours watching it, so I assumed that the software knew what it was doing. After the progress bar was no longer showing, cat /proc/mdstat displays: md0 : active raid1 sdb1[2](S) sdc1[1] 1953511288 blocks super 1.2 [2/1] [U_] And sudo mdadm --detail /dev/md0 shows: /dev/md0: Version : 1.2 Creation Time : Sun May 27 11:26:05 2012 Raid Level : raid1 Array Size : 1953511288 (1863.01 GiB 2000.40 GB) Used Dev Size : 1953511288 (1863.01 GiB 2000.40 GB) Raid Devices : 2 Total Devices : 2 Persistence : Superblock is persistent Update Time : Mon May 28 11:16:49 2012 State : clean, degraded Active Devices : 1 Working Devices : 2 Failed Devices : 0 Spare Devices : 1 Name : Deltique:0 (local to host Deltique) UUID : 49733c26:dd5f67b5:13741fb7:c568bd04 Events : 32365 Number Major Minor RaidDevice State 1 8 33 0 active sync /dev/sdc1 1 0 0 1 removed 2 8 17 - spare /dev/sdb1 I've been told that mdadm automatically replaces removed drives with spares, but /dev/sdb1 isn't being moved into the expected position, RaidDevice 1. UPDATE (30 May 2012): A badblocks destructive read-write test of the entire /dev/sdb yielded no errors as expected; both HDDs are new. As of the latest edit, I assembled the array with this command: sudo mdadm --assemble --force --no-degraded /dev/md0 /dev/sdb1 /dev/sdc1 The output was: mdadm: /dev/md0 has been started with 1 drive (out of 2) and 1 rebuilding. Rebuilding looks like it's progressing normally: md0 : active raid1 sdc1[1] sdb1[2] 1953511288 blocks super 1.2 [2/1] [U_] [>....................] recovery = 0.6% (13261504/1953511288) finish=2299.7min speed=14060K/sec unused devices: <none> I'm now waiting on this rebuild, but I'm expecting /dev/sdb1 to become a spare just like the five or six times that I've tried rebuilding before. UPDATE (31 May 2012): Yeah, it's still a spare. Ugh! UPDATE (01 June 2012): I'm trying Adrian Kelly's suggested command: sudo mdadm --assemble --update=resync /dev/md0 /dev/sdb1 /dev/sdc1 Waiting on the rebuild now... My questions are: Why isn't the spare drive becoming active sync? How can I make the spare drive become active?

    Read the article

  • Reasons for missing IP info in `last` output on pts logins?

    - by Mike Pennington
    I have five CentOS 6 linux systems at work, and encountered a rather strange issue that only seems to happen with my userid across all the linux systems I have... This is an example of the problem from entries I excepted from the last command... mpenning pts/19 Fri Nov 16 10:32 - 10:35 (00:03) mpenning pts/17 Fri Nov 16 10:21 - 10:42 (00:21) bill pts/15 sol-bill.local Fri Nov 16 10:19 - 10:36 (00:16) mpenning pts/1 192.0.2.91 Fri Nov 16 10:17 - 10:49 (12+00:31) kkim14 pts/14 192.0.2.225 Thu Nov 15 18:02 - 15:17 (4+21:15) gduarte pts/10 192.0.2.135 Thu Nov 15 12:33 - 08:10 (11+19:36) gduarte pts/9 192.0.2.135 Thu Nov 15 12:31 - 08:10 (11+19:38) kkim14 pts/0 :0.0 Thu Nov 15 12:27 - 15:17 (5+02:49) gduarte pts/6 192.0.2.135 Thu Nov 15 11:44 - 08:10 (11+20:25) kkim14 pts/13 192.0.2.225 Thu Nov 15 09:56 - 15:17 (5+05:20) kkim14 pts/12 192.0.2.225 Thu Nov 15 08:28 - 15:17 (5+06:49) kkim14 pts/11 192.0.2.225 Thu Nov 15 08:26 - 15:17 (5+06:50) dspencer pts/8 192.0.2.130 Wed Nov 14 18:24 still logged in mpenning pts/18 alpha-console-1. Mon Nov 12 14:41 - 14:46 (00:04) You can see two of my pts login entries above that do not have a source IP address associated with them. My CentOS machines have as many as six other users that share the systems, but the mpenning userid is the only one that has this issue. Approximately 5% of my logins see this issue, but no other usernames exhibit this behavior. Questions Given the kind of scripts I keep on these systems (which control much of our network infrastructure), I'm a little spooked by this and would like to understand what would cause my logins to occasionally miss source addresses. Is there anything (other than malicious activity) that would reasonably explain the behavior? Other than bash history timestamping, are there other things I can do to track the issue down? Informational Since this started happening, I enabled bash history time-stamping (i.e. HISTTIMEFORMAT="%y-%m-%d %T " in .bash_profile) and also added a few other bash history hacks; however, that does not give clues to what happened during the previous occurrences. All the systems run CentOS 6.3... [mpenning@typo ~]$ uname -a Linux typo.local 2.6.32-279.9.1.el6.x86_64 #1 SMP Tue Sep 25 21:43:11 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux [mpenning@typo ~]$ EDIT If I use last -i mpenning, I see entries like this... mpenning pts/19 0.0.0.0 Fri Nov 16 10:32 - 10:35 (00:03) mpenning pts/17 0.0.0.0 Fri Nov 16 10:21 - 10:42 (00:21)

    Read the article

< Previous Page | 29 30 31 32 33 34 35 36 37 38 39  | Next Page >