Search Results

Search found 1073 results on 43 pages for 'firmware'.

Page 34/43 | < Previous Page | 30 31 32 33 34 35 36 37 38 39 40 41  | Next Page >

  • Finding cause of TCP retransmission within a LAN

    - by Surreal
    Hello denizens of Server Fault I have an irritating problem with a LAN of about 100 computers, 2 Windows domain servers, and 12 VoIP phones. Since their installation around a year ago, every week or so, we notice a VoIP phone resetting itself - occasionally in the middle of a call. Simultaneously there are often signs of temporary loss of connection on computers: freezes in explorer while accessing network shares, errors in our administration software due to loss of connection to the database server. I have been doing some Wireshark monitoring on the connection between the VoIP PBX and the rest of the network. Wireshark picks up a clump of retransmitted TCP packets at the times when we record phone restarts. The Wireshark log shows about 2 clusters of retransmissions a day ranging from 5 packets to hundreds. Those in each cluster are mainly between the PBX and some set of the VoIP phones, but not always the same set. Often retransmissions at the same time are to phones connected to the same switch, but sometimes retransmissions occur together to phones at opposite ends of the network. There are usually some coincident retransmissions in passing TCP traffic, for example between client machines and the file servers. The spikes in retransmissions and phone resets do not correlate well with when the network is heavily loaded. They seem to occur slightly more during the day, but most in the evening, when traffic should be decreasing. They occur reasonably often late at night when most computers are turned off and traffic should be lowest. Do you have any ideas that might help diagnose the cause of problems like this? One thing I have not yet tried, but should have, is updating the firmware of all the switches.

    Read the article

  • Why do I have problems downloading some iPhone attachments from Exchange?

    - by CT
    Lately I have been getting an increasing number of complaints regarding users not being able to download attachments synced from Exchange with their iPhone. The iPhones in question are either 3G or 3GS with firmware 3.0 or later. Exchange 2007. The majority of messages come in just fine. Some however display: "This message has not been downloaded from the server" where the email's text normally should be. At the bottom of the email, it states: "This message is only partially downloaded." It has a button labeled "Download remaining 0 bytes." If you click this button, it states that it is loading and then reverts to the same screen. The odd part is that this only affects some emails. Most come in fine with attachments working. I've taken the same email that was not working on my iPhone. Sent it to a gmail account that my iPhone had access to. The message and attachment opened fine. Any ideas of possible causes I could look into? Thanks.

    Read the article

  • Upgrade Nokia Maps from v2 to v3 fails

    - by ssollinger
    I'm trying to install Nokia Maps 3.0 on my Nokia N82, without much success. I believe other similar Nokia phones have the same problem. My phone is connected through USB in "PC Suite" mode, and the latest firmware available for N82 is installed. I currently have Maps 2.0 installed. I'm installing from a Windows XP PC, and tried the update first from within Ovi Suite (latest version) and from Nokia Maps Updater (latest version). In both cases it detects that there is an update available (Maps 3.0), downlowds it and starts the install. On my phone, I then get the following error message: Unable to install. Component is built in. And on the PC I get the error Error Cannot update maps application. The installation failed or was cancelled on the phone (18). I found an entry for Maps in the App. manager and deleted it (and turned phone off and on again afterwards), but this didn't make any difference (and I don't think it changed the version of Maps installed either). This is the release version of Maps 3.0, not the beta. I found the problem mentioned many times on various web sites, but couldn't find a solution anywhere. Has anybody any ideas how to get the upgrade from Maps 2.0 to Maps 3.0 to work?

    Read the article

  • LSI MegaRAID LINUX got Optimal after degradation but strange POST message

    - by kesrut
    Linux server box with LSI MegaRAID controller got degraded. But after some time RAID status changed to Optimal. Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 2.727 TB Mirror Data : 2.727 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 3 Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Is VD Cached: No But now I'm getting RAID BIOS POST message: Your battery is either charging, bad or missing, and you have VDs configured for write-back mode. Because the battery is not currently usable, these VDs willl actually run in write-through mode until the battery is fully charged or replaced if it is bad or missing. (Image: http://cl.ly/image/1h1O093b1i2d) So may it be battery issue caused problem ? I get information about battery: BatteryType: iBBU Voltage: 4001 mV Current: 0 mA Temperature: 22 C Battery State : Operational BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : No Periodic Learn Required : No Transparent Learn : No No space to cache offload : No Pack is about to fail & should be replaced : No Cache Offload premium feature required : No Module microcode update required : No Where can be problem ? I'm disabled alarms, but get them if enabled. But don't know how find root of problem.

    Read the article

  • Resolving a BSOD/CPU/GPU issue...

    - by Christian Sciberras
    Hello all, I'm getting a BSOD / system crash (sometimes the PC just quits without a BSOD). Hardware Specifications cpu: i7 920 2666MHz / 8 cores (not OCed afaik) mobo: Asus P6T SE ram: 2x Corsair CM3X2G1333C9 (64bit DDR3 667MHz) gfx: ATI Radeon HD 5970 1GB (XFX HD5970 BE) os: Windows 7 Ultimate 64 bit (legit) All bios, firmware and drivers are all up to date (as of today). Symptoms Sometimes the PC runs smoothly, sometimes I get this BSOD. The BSOD always happens when I'm doing something related to graphics, such as viewing a video or playing a game. I get to know about the imminent BSOD ~10 seconds earlier; the PC starts freezing occasionally but increasing in frequency and length of lag (I noticed processor usage in creased from Process Monitor). I've tweaked BIOS settings occasionally but afaik, it was in vain. A day or so ago, I reset it to factory settings. BSOD contents The computer has rebooted from a bugcheck. The bugcheck was: 0x00000101 (0x0000000000000019, 0x0000000000000000, 0xfffff88001f35180, 0x0000000000000004). 15-12-2010 A fatal hardware error has occurred. Reported by component: Processor Core Error Source: Machine Check Exception Error Type: Internal Timer Error Processor ID: 4 23-12-2010 A fatal hardware error has occurred. Reported by component: Processor Core Error Source: Machine Check Exception Error Type: Internal Timer Error Processor ID: 2 Important The interesting thing is that although the event log (and BSOD screen) blame a "secondary processor", Windows Action Center sometimes blamed the GFX driver (for the same error). Also It is interesting to note that after hibernating my PC, I always get the BSOD.

    Read the article

  • I/O Error on LG GSA-H12N DVD drive on Windows 7

    - by Ashwin
    I am facing an I/O Error when I try to burn DVD data discs on my LG GSA-H12N DVD drive on Windows 7. Note that I was able to do this same operation on the same hardware/software just a day earlier without any problems, but with Windows XP. The only change (AFAIK) has been the installation of Windows 7 to replace Windows XP on this PC. Here is the error I get when I try to burn a DVD data disc using CDBurnerXP 4.2.7.1801: Burning error occured An error occured while burning the disc. Most likely the disc is not usable. Usually these errors happen if the inserted media is not compatible to the drive or of poor quality. (devNTSPTI_IO_Error) Could not write to Disc (LBA: 52864 Length: 32). SCSI Pass-through Interface I/O Error. - 0xFF045D Note that there can be no problem with the discs since I have been using the same discs (from the same box) just before the Windows 7 installation with no problems. The only change has been Windows 7. I tried InfraRecorder v0.5 and ImgBurn v2.5 and got similar I/O errors: Note that Windows 7 lists the LG GSA-H21N drive as being compatible (see this link). I also checked the LG Drivers website and using the firware update from there updated the drive firmware from version UL01 to UL02. But, even this has not helped. The drive reads DVDs without any problem, but continues to produce coasters. Could someone help me figure out what is the problem? Thanks :)

    Read the article

  • CentOS networking BNX2

    - by james moore
    Having some trouble with my NICs. The server starts fine and I can wget/ping etc. However, when I /etc/init.d/networking restart I then receive the following error: Bringing up interface eth0: bnx2: fw sync timeout, reset code = 1030009 SIOCSIFFLAGS: Device or resource busy Consequently, the task fails. I have searched around on google users suggesting to disable PNP in the BIOS but I see no option. Here is some system information: $ ethtool -i eth0 driver: bnx2 version: 2.0.8-rh firmware-version: bc 2.9.1 $ uname -a Linux host 2.6.18-238.9.1.el5 #1 SMP Tue Apr 12 18:10:13 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux $/sbin/lspci | grep Broadcom 04:00.0 PCI brodge: Broadcom EPB PCI-Express to PCI-X Bridge (rev c3) 05:00.0 Ethernet controller: Broadcom Corporation NetXtreme II BCM5700 Gigabit Ethernet (rev 12) 08:00.0 PCI brodge: Broadcom EPB PCI-Express to PCI-X Bridge (rev c3) 09:00.0 Ethernet controller: Broadcom Corporation NetXtreme II BCM5700 Gigabit Ethernet (rev 12) $ lsmod | grep bnx2 bnx2i 81704 0 cnic 109512 1 bnx2i libiscsi2 77765 6 be2iscsi,ib_iser,iscsi_tcp,bnx2i,cxgb3i,libiscsi_tcp scsi_transport_iscsi2 73945 8 be2iscsi,ib_iser,iscsi_tcp,bnx2i,cxgb3i,libiscsi2 bnx2 224780 0 scsi_mod 199001 15 mpt2sas,scsi_transport_sas,mptctl,be2iscsi,ib_iser,iscsi_tcp,bnx2i,cxgb3i,libiscsi2,scsi_transport_iscsi2,scsi_dh,sg,libata,megaraid_sas,sd_mod $ rmmod bnx2; modprobe bnx2 PCI: Enabling device 0000:05:00.0 (0158 -> 015a) PCI: Enabling device 0000:09:00.0 (0158 -> 015a) bnx2: fw sync timeout, reset code = 10300003 Any help would be appreciated as I am at a loss.

    Read the article

  • Rebuild Apple RAID set

    - by Clinton Blackmore
    We have a Mac Pro tower with an Apple RAID card in it using third party drives. When one drive failed, we replaced it and the RAID 5 set was nearly done rebuilding when the computer was rebooted. It did not come back up. We are now booting up off of a different internal volume, and have three (third-party) drives of identical spec (including revision and firmware) in the box. One of the drives is a global spare; the other two are recognized as belong to a RAID set but are in "Roaming" mode. The intention is to recreate the three-drive RAID set using the data on the two drives that are good. When we tell the system to create a RAID 5 using the three drives, it tells us that it'll create a RAID set but everything will be lost. There are no obvious options to rebuild a RAID using the two good drives and incorporating the third drive in Apple's RAID Utility, and we've looked through the options for the raidutil command. Fortunately, all important data is backed up, and we can rebuild from scratch, but, is there any way to make the RAIDset work again?

    Read the article

  • Connecting XRAID to Sunfire via LSI FC card - Drives not showing up

    - by Matthew Watson
    Hi, I've got a Sunfire T1000 machine ( Solaris 10 10/09 s10s_u8wos_08a SPARC ) with a LSI7404EP-LC fibre channel card in it. This is plugged into an XRAID. The system seems to have picked up the card > /usr/platform/`uname -i `/sbin/prtdiag IO Location Type Slot Path Name Model ----------- ----- ---- --------------------------------------------- ------------------------- --------- MB/PCIE0 PCIE 0 /pci@780/fibre-channel fibre-channel MB/PCIE0 PCIE 0 /pci@780/fibre-channel fibre-channel MB/NET0 PCIE MB /pci@7c0/pci@0/network@4 network-pci14e4,1668 MB/NET1 PCIE MB /pci@7c0/pci@0/network@4,1 network-pci14e4,1668 MB/NET2 PCIX MB /pci@7c0/pci@0/pci@8/network@1 network-pci108e,1648 MB/NET3 PCIX MB /pci@7c0/pci@0/pci@8/network@1,1 network-pci108e,1648 MB/PCIX PCIX MB /pci@7c0/pci@0/pci@8/scsi@2 scsi-pci1000,50 LSI,1064 However it doesn't seem to be able to see the xraid attached to it, lsiutil only reports the onboard SAS controller. > /usr/local/bin/lsiutil ~ LSI Logic MPT Configuration Utility, Version 1.62, January 14, 2009 1 MPT Port found Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC 1. mpt0 LSI Logic SAS1064 A3 105 010a0000 0 Select a device: [1-1 or 0 to quit] I've tried adding the configuration to /kernal/drv/sd.conf and /kernal/drv/ssd.conf as per this thread, however format still cannot see any drives on the xraid. I'm not sure where to go next. Any suggestions? From what I've read..this should pretty much just eb plug it in and they show up in format..

    Read the article

  • Port forwarding on D-Link DIR-615 super-slow, useless

    - by Jaroslav Záruba
    Hello I have replaced my old router with DIR-615 from D-Link, and now the port forwarding is so slow it makes the router practically useless for requests coming from outside of my network. Accessing the router itself (admin UI) from outside is without any issues, no delay whatsoever. But when I try to access a service residing on any of the computers in my network from outside the requests take minutes and minutes. (E.g. I can see source of my GWT-app main page, but loading additional CSS and JS files takes years.) If anyone could recommend any further diagnostics I should do to figure out what is happening it would be great. Few notes: happens with more services (web-app on Tomcat, viewing directory index via Apache) it does not make a difference whether the service is hosted on wired or wireless PC accessing the service on a localhost works fine, as does any 'inner' communication turning off firewall on target PC does not make difference either (makes sense) when I replace this router with the old one (both 192.168.1.1) everything works fine I see nothing suspicious in the router's log I believe I have the latest firmware (4.11) DIR-615 sucks, it already died once completely Regards Jarda Z.

    Read the article

  • Ubuntu lucid, maverick high iowait

    - by netom
    I'm using Ubuntu, and I've got the same problem with Lucid and Maverick. From time to time, especially a few minutes after boot, the iowait goes between 50-100% and the box is unusable. Everything that tries to access the disk freezes. I have the following setup: Hard disk: Model Family: Western Digital Caviar Green family Device Model: WDC WD15EADS-00P8B0 Serial Number: WD-WMAVU0391287 Firmware Version: 01.00A01 User Capacity: 1.500.301.910.016 bytes I have a quad core Intel Core2 Q6600 processor, and 4G of memory. When the high iowait occurs, usually 4 processes are active: kdmflush (two procs) jbd2/dm-0-8 jbd2/db-1-8 and a few more starving user processes of course. I know this from top and iotop. Any suggestions about why this is happening? There are a lot of q/a-s about linux and high iowait, but none of them helped so far, I even tweaked the hard disk not to park the head in every 8 seconds (Load cycle count is 50334!!!!! :o ), but nothing. Problem persists. Thank you in advance.

    Read the article

  • Where to get grub files without using grub-install

    - by Jacky
    I am in a particular situation. I have a MacBook Pro with no internal CD drive and both MacOS X (minimal setup) and Linux (my main system) is installed. During a cross-upgrade to Ubuntu 12.04 I messed up grub, so that my /boot/grub directory is basically empty. This means I can't boot Linux on the laptop anymore but only get into grub rescue. Normally this is no issue as you'd just boot from a rescue CD or USB stick, but unfortunately with a MacBook Pro this is not possible (I have reFIT installed and it attempts to boot, but it fails and the manual says that Apple's EFI firmware is not able to handle this situation). From MacOS X, however, I still have write access to the Linux partition. I've now been trying to figure out how to populate the /boot/grub folder with the necessary files, to no avail so far. The ISO image of Ubuntu 12.04 contains an EFI folder which is not what I am looking for, instead I need the normal.mod files for the grub version of Ubuntu 12.04. I do not have any other machine to set up a virtual machine of Ubuntu 12.04 to extract this from after a grub-install, so I am asking for ideas here how to solve this mess. P.S.: I installed the Linux previously when I still had a working internal CD drive. This is gone now.

    Read the article

  • how to initialize two logical drives on a HP P400i controller without reboot

    - by John
    What I am trying to do is initialize two logical drives on a HP P400i embedded controller without a reboot of the system here my current Array config: array A (SAS, Unused Space: 0 MB) logicaldrive 1 (17.9 GB, RAID 5, OK) logicaldrive 2 (17.9 GB, RAID 5, OK) logicaldrive 3 (75.9 GB, RAID 5, OK) logicaldrive 4 (25.0 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 5 (99 MB, RAID 0, OK) logicaldrive 6 (68.2 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) windows 2003 machine running the HpCISs2.sys driver version 6.20.0.32 . I have the ACU and ACU CLI tools installed version 8.28.13.0, P400i firmware version 2.74 . Now what I'd like to do is removes the physical drive 1I:1:4 and delete the two logical drives in array B. then insert a new drive in to bay 4 that contains two new logical drives and have them show up in array B again. So far after I remove the drive and delete the failed logical drives, I insert the new drive and run HPacucli rescan. I get the new drive to show up as unassinged physical drive but I cant figure out now to "for lack of a better word" mount the 2 logical drives on the new unassinged disk. If I reboot the system the array controller picks up the new fourth drive and creates Array B with the drives without problem but I'd really like to not have to reboot the server. Any ideas?

    Read the article

  • Extend RAID 1 (HP SmartArray P410i) running Linux

    - by Oliver
    I took over a fairly simple server setup with the following RAID 1 config running Ubuntu 11.10 (Kernel 3.0.0-12-server x86_64): => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: removed) array A (SAS, Unused Space: 1335535 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 1 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 1 TB, OK) Initially there were two 300GB disks that got replaced by 1TB disks and I now have to extend the logical volume to use that extra space. However, when trying to do so I get the following warning: => ctrl slot=0 ld 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n) Is it safe to say yes or am I at risk of corrupting the file system / loosing data? Rearranging and extending the file system afterwards shouldn't be an issue as I can take the server offline and boot from a gparted live disk. Here's the config of the RAID controller in use: => ctrl all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: removed RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 5.12 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True And the partition table: Number Start End Size Type File system Flags 1 1049kB 274GB 274GB primary ext4 boot 2 274GB 300GB 25.8GB extended 5 274GB 300GB 25.8GB logical linux-swap(v1)

    Read the article

  • Restore passwd for root on a server

    - by s.mihai
    Hello,       I have a DVR server with linux embeded. It has some telnet functions but i don't have the password for it (the chinese manufacturer refuses to give me the password). I did get a upgrade folder from them and found a passwd file inside.       So i assume that when i upgrade the firmware the password in that file will be used.       Now i am trying to modify the file so taht i can insert a password i already know.       The problem is that i don't know how to create the password hash from what i figured the password hash is $1$1/lfbDKX$Hmd.FqzB8IZEohPesYi961       The file is named rom.ko and i found a command telnetd /mnt/yaffs/web/boa -c /mnt/yaffs/web & /bin/cp -f /mnt/yaffs/rom.ko /etc/shadow in a script file so i assume this is the right way.       Can you help me reconstruct a password that i know already? Tell me how or make one for me :) ?... passwd file: root:$1$1/lfbDKX$Hmd.FqzB8IZEohPesYi961:0:0:99999:7:-1:-1:33637592 bin::10897:0:99999:7::: daemon::10897:0:99999:7::: adm::10897:0:99999:7::: lp::10897:0:99999:7::: sync::10897:0:99999:7::: shutdown::10897:0:99999:7::: halt::10897:0:99999:7::: mail::10897:0:99999:7::: news::10897:0:99999:7::: uucp::10897:0:99999:7::: operator::10897:0:99999:7::: games::10897:0:99999:7::: gopher::10897:0:99999:7::: ftp::10897:0:99999:7::: nobody::10897:0:99999:7::: next::11702:0:99999:7:::

    Read the article

  • Mac OS X - configuring ntpd server with on LAN with D-Link DIR-655

    - by Mark C
    Hey all, This question is pretty specific, but I hope someone will have seen this error elsewhere. I a configuring a machine running OS X 10.5.8 to be an NTP server for machines connected to a LAN that is not connected to the Internet. I am not too worried about knowing the "right" time on all the machines, but rather worried about making sure everyone has the same notion of time. I configured the NTP daemon on Mac by turning on the Set date and time automatically in System Preferences, using the server's clock, 127.127.1.0 as the reference clock. I figured I should see if the server can NTP query itself before proceeding to the clients. The weird part is when I run the ntpq -p command in a command-prompt when connected to my D-Link DIR-655 (firmware: 1.33), it hangs for about a minute or so each time before finally giving me some output. I thought the problem might have to do with Port Forwarding, so I configured the router to forward port 123 for the IP of the server, but that did not improve the situation. When I run the ntpq -p command on my school's network, on a Linksys WRT54G router, or with the wireless Airport card turned off - I have absolutely no problems - the command returns a response instantly. Is this normal? I can see why a query might take a minute or so, but I don't understand why one router does it faster than the other. I tried messing around with the ntp.conf file adding the burst, minpoll, and maxpoll options: server 127.127.1.0 burst minpoll 4 maxpoll 5 Figuring that perhaps I am polling too often and the configuration file is slowing me down, but even with this, the ntpq still hangs on the D-Link DIR-655, but does just fine on the other routers. Any thoughts on where the lag is coming from or if the lag is even a problem?

    Read the article

  • Unable to write DVD-R(Blank DVD's)

    - by FrozenKing
    I have a problem in dvd drive i.e. It can read CD/DVD and can write CD and all CD/DVD-RW but cannot write DVD DVD drive model is SH-S203B Samsung; I also have a log file created by nero burning rom 11. Actually the fact is no Blank DVD's are being read in my dvd drive only previously written dvd's can be read! Is this the problem of OS or should I try cleaning the dvd drive or my DVD drive is 4yrs old so is it going to spoil now, since it is showing this type of symptoms! OS = WinXP AV = KIS 2012 DVD Drive = Samsung SH-S203B (Also tried latest firmware and downgrade versions also) IA32 Nero Version: 11.2.4.100 Internal Version: 11,2,4,100 Recorder: <TSSTcorp CDDVDW SH-S203B>Version: SB04 - HA 1 TA 0 - 11.2.4.100 Adapter driver: <Serial ATA> HA 1 Drive buffer : 2048kB Bus Type : via Inquiry data CD-ROM: <TSSTcorp CDDVDW SH-S203B >Version: SB04 - HA 1 TA 0 - 11.2.4.100 Adapter driver: <Serial ATA> HA 1 18:58:10 #37 SPTI -1511 File SCSIPassThrough.cpp, Line 224 CdRom0: SCSIStatus(x02) WinError(0) NeroError(-1511) CDB Data: 0x28 00 00 00 00 00 00 00 10 00 Sense Key: 0x04 (KEY_HARDWARE_ERROR) Sense Code: 0x3E Sense Qual: 0x02 Sense Area: 0x70 00 04 00 00 00 00 0A 00 00 00 00 3E 02 Buffer x08047340: Len x8000 18:58:10 #38 SectorVerify 20 File Cdrdrv.cpp, Line 12057 Read errors from sector 0 to 14 <Padding> 18:58:19 #39 SPTI -1511 File SCSIPassThrough.cpp, Line 224 CdRom0: SCSIStatus(x02) WinError(0) NeroError(-1511) CDB Data: 0x28 00 00 00 00 10 00 00 10 00 Sense Key: 0x04 (KEY_HARDWARE_ERROR) Sense Code: 0x3E Sense Qual: 0x02 Sense Area: 0x70 00 04 00 00 00 00 0A 00 00 00 00 3E 02 Buffer x08047340: Len x8000 18:58:19 #40 SectorVerify 21 File Cdrdrv.cpp, Line 12057 Read error at sector 15 <Virtual Multisession Info> 18:58:19 #41 SectorVerify 20 File Cdrdrv.cpp, Line 12057 Read errors from sector 16 to 18 <Volume Structure Descriptor Sequence> 18:58:28 #42 SPTI -1511 File SCSIPassThrough.cpp, Line 224 CdRom0: SCSIStatus(x02) WinError(0) NeroError(-1511) CDB Data: 0x28 00 00 00 00 20 00 00 10 00 Sense Key: 0x04 (KEY_HARDWARE_ERROR) Sense Code: 0x3E Sense Qual: 0x02 Sense Area: 0x70 00 04 00 00 00 00 0A 00 00 00 00 3E 02 Buffer x08047340: Len x8000

    Read the article

  • PDU management interface has low availability - product flaw or isolated issue

    - by DeanB
    Our colocation provider has supplied us with APC AP7932 switched 0U PDUs as part of several cabinets they provide us. We have had a lot of trouble with the network management aspect of these PDUs, which I'll describe below. We are moving to cage space in the same datacenter, and plan to provide our own PDUs, so I'd like to determine which enterprise-grade PDUs have been reliable performers from a remote management perspective. Our colo-provided PDUs are configured to support management via an SSL web UI and via telnet. We updated the firmware on all of them to the current version as of NOV2011. They respond to pings reliably, and we have no reason to suspect a network layer issue. However, we experience frequent hangs, timeouts, disconnects, and general unavailability from the embedded management host in all of the PDUs. We occasionally have to restart the microcontroller on the PDU to recover from what appears to be an occasional hard fault. The outlets stay powered (thankfully), but the management aspect is so unreliable that it has become an ops liability - we can't be confident that we could get into the PDU to power cycle a host if we needed to. We have 3 PDUs that all exhibit identical behavior. There are many manufacturers of enterprise-grade 0U switched PDUs, all with comparable features. If I looked at the datasheet for our current PDUs, they would appear to be a good fit -- only with the benefit of suffering through using them do we know to avoid them. I'd like to avoid picking a PDU that looks fine on paper, but has similar reliability issues. What has been others' experience with switched PDUs? Is this level of flakiness normal?

    Read the article

  • Is it possible to provide a wired ethernet connection to external devices with an extra LAN card?

    - by Ben McCormack
    I'm trying to provide a wired ethernet connection (wireless is not an option for this device) to a device (Samsung blu-ray player) without running Cat5 cable all over the home. I have a PC sitting next to this device and the PC is connected to the network via a wireless USB adapter. Is it possible to provide a wired connection from the PC to the wired device using the (currently unused) ethernet port in the back of the computer? Here's how I envision the device getting connected to the internet via my network: Linksys WRT54G v8 Wireless Router | ``--> Windows 7 PC connected via wireless | ``--> Blu-ray player connected via wired connection to the ethernet port on the PC. If so, how is this done? Will I need a crossover cable? What settings will I need to change in Windows 7 so that the device can connect? NOTE: I'm trying to avoid having to buy a wireless bridge and/or hacking a router with an open-source firmware to get this to work. See my previous question for more details.

    Read the article

  • Simple options for port forwarding to a different port?

    - by Nick
    I have three network printers at our local office, all of which listen on port 9100. Non of them offer the option of changing the listening port. We have a single public static IP address, and access to our main network is through a Linksys WRT-54G. We need to be able to print to these printers from outside the office. The problem is, with the 54G, I can only forward a port to the SAME port on a particular IP address. What I really need though is a way to forward to an ip address and a DIFFERENT port. I need to do this: In port Destination 9100 192.168.1.1 : 9100 9101 192.168.1.2 : 9100 9102 192.168.1.3 : 9100 So I'm looking for options. I could setup an old computer with two network cards and IPtables I suppose, but that seems like a lot of overhead for something relatively simple. Is there a way a virtual machine (read: one network card) could do the advanced port forwarding? Where I forward all traffic to it, and it forwards it on to the right printer? Or what about those mini Linux distros that replace the WRT-54G's firmware? Do any of those support what I need "out of the box"? I have a spare WRT- could I make it an IP tables router? Recommendations for mini distros? Or is there an off-the-shelf product that does this (cheap/local preferred)? Any advice / options appreciated. Thanks!

    Read the article

  • Is current SATA 6 gb/s equipment simply unreliable?

    - by korkman
    I have a 45-disk array of Seagate Barracuda 3 TB ST3000DM001 (yes these are desktop drives I'm aware of that) in a Supermicro sc847 JBOD, connected via LSI 9285. I have found a solution for the problem description below by reducing speed via MegaCli -PhySetLinkSpeed -phy0 2 -a0; for i in $(seq 48); do MegaCli -PhySetLinkSpeed -phy${i} 2 -a0; done and rebooting. The question remains: Is this typical for current 6 gb/s equipment? Is this the sad state of SATA storage? Or is some of my equipment (the sff-8088 cables come to mind) bad? The Problem was: Synchronizing HW RAID-6, disks kept offlining. Fetching SMART values reveiled that those which offlined did not increase powered-on hours anymore. That is, their firmware (CC4C) seems to crash. Digging into the matter by switching to Software RAID-6, with the disks passed-through, I got tons of kernel messages scattered across all disks, with 6 gb/s: sd 0:0:9:0: [sdb] Sense Key : No Sense [current] Info fld=0x0 sd 0:0:9:0: [sdb] Add. Sense: No additional sense information And finally, when a disk offlines: megasas: [ 5]waiting for 160 commands to complete ... megasas: [35]waiting for 159 commands to complete ... megasas: [155]waiting for 156 commands to complete ... megaraid_sas: pending commands remain after waiting, will reset adapter. Ugly controller reset here, then minutes later: megaraid_sas: Reset successful. sd 0:0:28:0: Device offlined - not ready after error recovery ... sd 0:0:28:0: [sdu] Unhandled error code sd 0:0:28:0: [sdu] Result: hostbyte=DID_ERROR driverbyte=DRIVER_OK sd 0:0:28:0: [sdu] CDB: Read(10): 28 00 23 21 2f 40 00 00 70 00 sd 0:0:28:0: [sdu] killing request Reduced speed to 3 gb/s like written above, all problems vanished.

    Read the article

  • CentOS 6 LEMP update - dependency error issue

    - by Latheesan Kanes
    I have setup a LEMP server following the guide Install Nginx/PHP-FPM on Fedora 20/19, CentOS/RHEL 6.5/5.10. It's been a while since I did the setup, so I wanted to grab the latest updates from REMI repository. I ran the following command: yum --enablerepo=remi,remi-php55 update I now get these dependency related errors: # yum --enablerepo=remi update Loaded plugins: fastestmirror Loading mirror speeds from cached hostfile * base: mirror.nl.leaseweb.net * epel: mirror.1000mbps.com * extras: mirror.nl.leaseweb.net * remi: remi.schlundtech.de * updates: centos.mirror1.spango.com Setting up Update Process Resolving Dependencies --> Running transaction check ---> Package chkconfig.x86_64 0:1.3.49.3-2.el6 will be updated ---> Package chkconfig.x86_64 0:1.3.49.3-2.el6_4.1 will be an update ---> Package glibc.x86_64 0:2.12-1.107.el6_4.4 will be updated ---> Package glibc.x86_64 0:2.12-1.107.el6_4.5 will be an update ---> Package glibc-common.x86_64 0:2.12-1.107.el6_4.4 will be updated ---> Package glibc-common.x86_64 0:2.12-1.107.el6_4.5 will be an update ---> Package gnupg2.x86_64 0:2.0.14-4.el6 will be updated ---> Package gnupg2.x86_64 0:2.0.14-6.el6_4 will be an update ---> Package iputils.x86_64 0:20071127-17.el6_4 will be updated ---> Package iputils.x86_64 0:20071127-17.el6_4.2 will be an update ---> Package kernel.x86_64 0:2.6.32-358.23.2.el6 will be installed ---> Package kernel-firmware.noarch 0:2.6.32-358.18.1.el6 will be updated ---> Package kernel-firmware.noarch 0:2.6.32-358.23.2.el6 will be an update ---> Package libgcrypt.x86_64 0:1.4.5-9.el6_2.2 will be updated ---> Package libgcrypt.x86_64 0:1.4.5-11.el6_4 will be an update ---> Package mysql-libs.x86_64 0:5.1.69-1.el6_4 will be updated --> Processing Dependency: libmysqlclient.so.16()(64bit) for package: 2:postfix-2.6.6-2.2.el6_1.x86_64 --> Processing Dependency: libmysqlclient.so.16(libmysqlclient_16)(64bit) for package: 2:postfix-2.6.6-2.2.el6_1.x86_64 ---> Package mysql-libs.x86_64 0:5.5.34-1.el6.remi will be an update ---> Package nginx.x86_64 0:1.4.2-1.el6.ngx will be updated ---> Package nginx.x86_64 0:1.4.3-1.el6.ngx will be an update ---> Package php-pear.noarch 1:1.9.4-20.el6.remi will be updated ---> Package php-pear.noarch 1:1.9.4-23.el6.remi will be an update ---> Package php-pecl-jsonc.x86_64 0:1.3.2-1.el6.remi.1 will be updated ---> Package php-pecl-jsonc.x86_64 0:1.3.2-2.el6.remi will be an update --> Processing Dependency: php(zend-abi) = 20100525-x86-64 for package: php-pecl-jsonc-1.3.2-2.el6.remi.x86_64 --> Processing Dependency: php(api) = 20100412-x86-64 for package: php-pecl-jsonc-1.3.2-2.el6.remi.x86_64 ---> Package php-pecl-mongo.x86_64 0:1.4.3-1.el6.remi.1 will be updated ---> Package php-pecl-mongo.x86_64 0:1.4.4-1.el6.remi will be an update --> Processing Dependency: php(zend-abi) = 20100525-x86-64 for package: php-pecl-mongo-1.4.4-1.el6.remi.x86_64 --> Processing Dependency: php(api) = 20100412-x86-64 for package: php-pecl-mongo-1.4.4-1.el6.remi.x86_64 ---> Package php-pecl-sqlite.x86_64 0:2.0.0-0.3.svn313074.el6.remi.5 will be updated ---> Package php-pecl-sqlite.x86_64 0:2.0.0-0.4.svn332053.el6.remi.5.4 will be an update --> Processing Dependency: php(zend-abi) = 20100525-x86-64 for package: php-pecl-sqlite-2.0.0-0.4.svn332053.el6.remi.5.4.x86_64 --> Processing Dependency: php(api) = 20100412-x86-64 for package: php-pecl-sqlite-2.0.0-0.4.svn332053.el6.remi.5.4.x86_64 ---> Package postgresql-libs.x86_64 0:8.4.13-1.el6_3 will be updated ---> Package postgresql-libs.x86_64 0:8.4.18-1.el6_4 will be an update ---> Package remi-release.noarch 0:6-2.el6.remi will be updated ---> Package remi-release.noarch 0:6.4-1.el6.remi will be an update ---> Package rsync.x86_64 0:3.0.6-9.el6 will be updated ---> Package rsync.x86_64 0:3.0.6-9.el6_4.1 will be an update ---> Package selinux-policy.noarch 0:3.7.19-195.el6_4.12 will be updated ---> Package selinux-policy.noarch 0:3.7.19-195.el6_4.18 will be an update ---> Package selinux-policy-targeted.noarch 0:3.7.19-195.el6_4.12 will be updated ---> Package selinux-policy-targeted.noarch 0:3.7.19-195.el6_4.18 will be an update ---> Package setup.noarch 0:2.8.14-20.el6 will be updated ---> Package setup.noarch 0:2.8.14-20.el6_4.1 will be an update ---> Package tzdata.noarch 0:2013c-2.el6 will be updated ---> Package tzdata.noarch 0:2013g-1.el6 will be an update ---> Package xinetd.x86_64 2:2.3.14-38.el6 will be updated ---> Package xinetd.x86_64 2:2.3.14-39.el6_4 will be an update --> Running transaction check ---> Package compat-mysql51.x86_64 0:5.1.54-1.el6.remi will be installed ---> Package php-pecl-jsonc.x86_64 0:1.3.2-2.el6.remi will be an update --> Processing Dependency: php(zend-abi) = 20100525-x86-64 for package: php-pecl-jsonc-1.3.2-2.el6.remi.x86_64 --> Processing Dependency: php(api) = 20100412-x86-64 for package: php-pecl-jsonc-1.3.2-2.el6.remi.x86_64 ---> Package php-pecl-mongo.x86_64 0:1.4.4-1.el6.remi will be an update --> Processing Dependency: php(zend-abi) = 20100525-x86-64 for package: php-pecl-mongo-1.4.4-1.el6.remi.x86_64 --> Processing Dependency: php(api) = 20100412-x86-64 for package: php-pecl-mongo-1.4.4-1.el6.remi.x86_64 ---> Package php-pecl-sqlite.x86_64 0:2.0.0-0.4.svn332053.el6.remi.5.4 will be an update --> Processing Dependency: php(zend-abi) = 20100525-x86-64 for package: php-pecl-sqlite-2.0.0-0.4.svn332053.el6.remi.5.4.x86_64 --> Processing Dependency: php(api) = 20100412-x86-64 for package: php-pecl-sqlite-2.0.0-0.4.svn332053.el6.remi.5.4.x86_64 --> Finished Dependency Resolution Error: Package: php-pecl-jsonc-1.3.2-2.el6.remi.x86_64 (remi) Requires: php(zend-abi) = 20100525-x86-64 Installed: php-common-5.5.4-1.el6.remi.x86_64 (@remi-test) php(zend-abi) = 20121212-64 Available: php-common-5.3.3-22.el6.x86_64 (base) php(zend-abi) = 20090626 Available: php-common-5.3.3-23.el6_4.x86_64 (updates) php(zend-abi) = 20090626 Available: php-common-5.4.21-1.el6.remi.x86_64 (remi) php(zend-abi) = 20100525-x86-64 Available: php-common-5.4.21-2.el6.remi.x86_64 (remi) php(zend-abi) = 20100525-x86-64 Error: Package: php-pecl-mongo-1.4.4-1.el6.remi.x86_64 (remi) Requires: php(zend-abi) = 20100525-x86-64 Installed: php-common-5.5.4-1.el6.remi.x86_64 (@remi-test) php(zend-abi) = 20121212-64 Available: php-common-5.3.3-22.el6.x86_64 (base) php(zend-abi) = 20090626 Available: php-common-5.3.3-23.el6_4.x86_64 (updates) php(zend-abi) = 20090626 Available: php-common-5.4.21-1.el6.remi.x86_64 (remi) php(zend-abi) = 20100525-x86-64 Available: php-common-5.4.21-2.el6.remi.x86_64 (remi) php(zend-abi) = 20100525-x86-64 Error: Package: php-pecl-jsonc-1.3.2-2.el6.remi.x86_64 (remi) Requires: php(api) = 20100412-x86-64 Installed: php-common-5.5.4-1.el6.remi.x86_64 (@remi-test) php(api) = 20121113-64 Available: php-common-5.3.3-22.el6.x86_64 (base) php(api) = 20090626 Available: php-common-5.3.3-23.el6_4.x86_64 (updates) php(api) = 20090626 Available: php-common-5.4.21-1.el6.remi.x86_64 (remi) php(api) = 20100412-x86-64 Available: php-common-5.4.21-2.el6.remi.x86_64 (remi) php(api) = 20100412-x86-64 Error: Package: php-pecl-sqlite-2.0.0-0.4.svn332053.el6.remi.5.4.x86_64 (remi) Requires: php(zend-abi) = 20100525-x86-64 Installed: php-common-5.5.4-1.el6.remi.x86_64 (@remi-test) php(zend-abi) = 20121212-64 Available: php-common-5.3.3-22.el6.x86_64 (base) php(zend-abi) = 20090626 Available: php-common-5.3.3-23.el6_4.x86_64 (updates) php(zend-abi) = 20090626 Available: php-common-5.4.21-1.el6.remi.x86_64 (remi) php(zend-abi) = 20100525-x86-64 Available: php-common-5.4.21-2.el6.remi.x86_64 (remi) php(zend-abi) = 20100525-x86-64 Error: Package: php-pecl-mongo-1.4.4-1.el6.remi.x86_64 (remi) Requires: php(api) = 20100412-x86-64 Installed: php-common-5.5.4-1.el6.remi.x86_64 (@remi-test) php(api) = 20121113-64 Available: php-common-5.3.3-22.el6.x86_64 (base) php(api) = 20090626 Available: php-common-5.3.3-23.el6_4.x86_64 (updates) php(api) = 20090626 Available: php-common-5.4.21-1.el6.remi.x86_64 (remi) php(api) = 20100412-x86-64 Available: php-common-5.4.21-2.el6.remi.x86_64 (remi) php(api) = 20100412-x86-64 Error: Package: php-pecl-sqlite-2.0.0-0.4.svn332053.el6.remi.5.4.x86_64 (remi) Requires: php(api) = 20100412-x86-64 Installed: php-common-5.5.4-1.el6.remi.x86_64 (@remi-test) php(api) = 20121113-64 Available: php-common-5.3.3-22.el6.x86_64 (base) php(api) = 20090626 Available: php-common-5.3.3-23.el6_4.x86_64 (updates) php(api) = 20090626 Available: php-common-5.4.21-1.el6.remi.x86_64 (remi) php(api) = 20100412-x86-64 Available: php-common-5.4.21-2.el6.remi.x86_64 (remi) php(api) = 20100412-x86-64 You could try using --skip-broken to work around the problem You could try running: rpm -Va --nofiles --nodigest Any idea how to solve these errors? Am I missing a package? or is this a bug?

    Read the article

  • The Server Fault Wiki of recommended practices [migrated]

    - by Avery Payne
    So I've noticed that there are several recommendations on basic practices on Server Fault, but there doesn't seem to be a cohesive view as to how those recommendations would all fit together. So I thought I would lump these together as a kind of mental exercise to see what the "ServerFault Community IT Department" would look like if it were implemented. This would give a few things: it would make a reasonable wiki (in the true wiki spirit of many contributions), it would provide several links to well-vetted practices, and it would be kind of fun to see what the amalgamation would look like. And who knows, it may even point out some interesting issues between different forms of "best practices", although I would be stunned if there was a conflict hidden in there someplace... Add your favorites from Server Fault as answers, and I'll re-edit this section with the results. Here's a few catagories to collect different ideas together. Hardware Configuration(s) Server room configuration. Server room temperature Firmware Updates and Scheduling Storage Configuration(s) Selecting a NAS box Linux: Dealing with /tmp Linux: Install apps in /var or /opt? Network Configuration(s) checking DNS health and compliance Security Practice(s) Password (General) Best Practices Password sharing methods Windows Update Updating Windows Servers that are hosts for VMs Network Service(s) User Service(s) User Naming & Deletion Upgrade Process(es) Disaster Recovery Checking Backups Documenting an outage for a post-mortem review Last Edit: 2010-02-17

    Read the article

  • Intel NIC X540-T1 non-functional in Ubuntu Server 12.04

    - by Jeff Carr
    I have installed three Intel X540-T1's in servers running Ubuntu Server 12.04, but all are non-functional, no link lights, no packets sent or received, and no connection on ip4 or ip6 whether set up as dhcp or static. Also, dmesg doesn't detect cable connection or disconnection. I updated the default ixgbe driver to Intel's latest version (3.11.33) with no change. The ethernet controller is being reported as X540-AT2 (which might be a problem that I can't figure out how to fix), but the subsystem is X540-T1 so I believe that might be intended. Does anyone have any experience with this that could assist? ifconfig eth2 eth2 Link encap:Ethernet HWaddr a0:36:9f:14:5f:ea inet addr:192.168.101.1 Bcast:192.168.101.255 Mask:255.255.255.0 UP BROADCAST MULTICAST MTU:1500 Metric:1<br> RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) ethtool -i eth2 driver: ixgbe version: 3.11.33 firmware-version: 0x8000037c bus-info: 0000:08:00.0 supports-statistics: yes supports-test: yes supports-eeprom-access: yes supports-register-dump: yes lspci -vvnns 08:00.0 08:00.0 Ethernet controller [0200]: Intel Corporation Ethernet Controller 10 Gigabit X540-AT2 [8086:1528] (rev 01) Subsystem: Intel Corporation Ethernet Converged Network Adapter X540-T1 [8086:0002] Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR+ FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0, Cache Line Size: 32 bytes Interrupt: pin A routed to IRQ 16 Region 0: Memory at e8000000 (64-bit, prefetchable) [size=2M] Region 4: Memory at e8200000 (64-bit, prefetchable) [size=16K] [virtual] Expansion ROM at e8280000 [disabled] [size=512K] Capabilities: <access denied> Kernel driver in use: ixgbe Kernel modules: ixgbe

    Read the article

  • Best way to execute a command after Linux system halt

    - by Lukas Loesche
    Problem: The SSDs in our servers require a power cycle (i.e. off/on, not reset/warm reboot) after a firmware update. Thoughts: Using 'ipmitool chassis power cycle' I can cycle the server's power. However this would cut the power while the system is still running, filesystems are mounted, etc. What I basically want is a delayed power cycle so the system has a change to halt. But I guess that would have to be implemented on the server's IPMI board, so it's not really an option. My initial idea was to dynamically create a ramdisk containing the tool and libs and somehow integrate that into the halt process. I saw there's a /etc/init.d/halt, so that would be my starting point. Although I believe the kernel at some point in the shutdown process starts to kill off remaining processes. So I'm not even sure if that's a viable way. Question: What would be the best way to execute ipmitool (or any other command), after the system has halted and all regular filesystems are unmounted?

    Read the article

< Previous Page | 30 31 32 33 34 35 36 37 38 39 40 41  | Next Page >