Search Results

Search found 68618 results on 2745 pages for 'internet com'.

Page 34/2745 | < Previous Page | 30 31 32 33 34 35 36 37 38 39 40 41  | Next Page >

  • Setting System.Drawing.Color through COM. Interop

    - by user58909
    I am trying to use Aspose.Words library through COM Interop. There is one critical problem: I cannot set color. It is supposed to work by assigning to DocumentBuilder.Font.Color, but when I try to do it I get OLE error 0x80131509. My problem is pretty much like this one: http://bit.ly/cuvWfc

    Read the article

  • C# and com for vb6

    - by Jim
    Hi all I have an issue with C# and COM. :( [Guid("f7d936ba-d816-48d2-9bfc-c18be6873b4d")] [ComVisible(true)] [ClassInterface(ClassInterfaceType.None)] public class Process : IProcess { public Process() { } public int UpdateBalance(string accountNumber, string adminEventDescription, decimal curAmount) { return 10; } } [ComVisible(true)] [Guid("5c640a0f-0dce-47d4-87df-07cee3b9a1f9")] [InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IProcess { int UpdateBalance(string accountNumber, string adminEventDescription, decimal curAmount); } And the VB code Private Sub Command1_Click() Dim test As Object Set test = New Forwardslash_PlayerTrackingSystem_Api.Process End Sub I get the following ActiveX component can't create object?

    Read the article

  • Registering a COM control during installation

    - by Curtis
    One of our applications needs to register a COM control during installation. If a newer version of that control is already registered, we don't want to overwrite it with the older. What are the Windows MSI install conditions I would user to control this? Or is there some other 'best-practice' method I'm not aware of? Thanks

    Read the article

  • Native.* assemblyIdentity with Registration-free com

    - by moogs
    I set Isolated=true to some COM library that I need to use registration free. Visual studio now created Native.* manifest files for each of my assemblies: Why "Native"? Can I change this? Can someone point me to info I can read? (googling native / assembly / manifest is yield a lot of non-related info ) Is there a way I can embed these manifest files into the assembly DLL? Thanks!

    Read the article

  • WCF wrapper COM object

    - by LarryR
    I have a third party COM component (they don't offer a .Net assy), that has the additional feature that it only works under x86 compile. I am trying to wrap this in a WCF service, but if I select x86, the service won't start (System.BadImageFormatException). Any workarounds for this ? Thanks Larry

    Read the article

  • COM(C++) Programming Tutorials

    - by Deep-B
    Hey guys, I was wondering if there're any good sites that deal with learning C++/COM from the ground up? Looking for something like a crash course (two weeks, and not being hypothetical here). Assume knowledge in standard C/C++, or at least not a complete dummy.

    Read the article

  • Salesforce.com s'attaque à Oracle avec Database.com, un service qui veut devenir « l'avenir des bases de données »

    Salesforce.com s'attaque à Oracle avec Database.com Une base de données 100 % hébergée qui veut révolutionner les SGBD Lors de sa conférence Dreamforce, qui se déroule actuellement à San Francisco, Salesforce.com, le plus célèbre éditeur de CRM en mode Cloud, vient de présenter un produit extrêmement ambitieux, qualifié par la société d'« avenir des bases de données ». Il s'agit de Database.com, le premier SGBD 100 % Cloud. La plate-forme veut supprimer les problématiques de l'optimisation et de la maintenance des bases de données et du matériel traditionnels. « Les bases de données Cloud représentent une opportunité majeure pour faciliter ...

    Read the article

  • IE8 Crash On Startup

    - by Wonko the Sane
    Hello All, I have a problem - IE8 has suddenly stopped working. I was doing some development work, and suddenly IE8 crashed every time I tried to use it. I've rebooted, but still crash every time I try to open it. There is no real indication as to what has gone wrong. It just says "Internet Explorer has stopped working". I've tried almost everything that I've seen when I've Googled it: I disabled all Add-Ins via Manage Add-Ins, but it still crashes on startup* I re-registered IEPROXY.DLL * The thing I don't understand is that if I start from the Run box with the -extoff option, IE starts up. Isn't that the same as disabling all Add-Ins? Any ideas? Thanks, wTs

    Read the article

  • How to remove google ads virus from IE?

    - by msbg
    I have picked up adware in that shows extra irrelevant google ads. This only happens in Internet Explorer 10, not Firefox or Iron. I have tried some removals for similar viruses with no luck. I have scanned with MalwareBytes, Windows Defender(I am using Windows 8 RTM, so this is the same as MSE), Spybot, Ad Aware, McAfee, Norton, and AVG, with no luck. Here's a screenshot: As you can see, ads are added to the tan area as well as several extra white results, which are especially irrelevant. I like IE10 and would like to keep using it, but these ads are annoying. I'm also worried there may be spyware as well.

    Read the article

  • Google Loon–A network of balloons to provide internet to everyone

    - by Gopinath
    Google once just a super powerful search engine provider and now they are venturing in to a lot of interesting non software projects like self driving cars, glasses that beam information right on to your eye balls, high speed internet services @ 1 Giga bytes per second. A recent addition to this innovative list is Google Loon – a network of flying balloons that provide internet access to remote parts of the world where it is not feasible for many governments/corporate to provider internet services. Google says there are several billions of people around the world who don’t have access to internet and Google Loon aim is to provide internet facilities to all these people. A pilot project is started couple of days ago by launching 30 balloons into stratosphere from New Zealand. These balloons fly 20 Kilometers above earth(much higher than where aero planes fly) and they beam internet to homes having Loon receiver wirelessly. Checkout the embedded introductory video on Google Loon What is in it for Google? Why is Google getting into these type of projects and what is in it for them? Google is the gateway to web and majority of people find information on web using Google Services/Software. So providing internet facilities to more people means, more people using Google services and it in turn contributes to their revenue growth. Google is not a charity, they do all these projects to earn money just like every other corporate. The best part is while earning money they are touching lives of billions of people in a positive way. Just imagine everyone in the world connected and have ability to take informed decisions irrespective of whether they live in developed countries or underprivileged parts of the world! Wow that will be a beautiful day. Further reading Google Loon website Google unveils its Project Loon Wi-Fi balloons – in pictures Google flies Internet balloons in stratosphere for a “network in the sky” How Google Will Use High-Flying Balloons to Deliver Internet to the Hinterlands Good discussion on Google Loon at Hacker News community

    Read the article

  • Why maximum 1.0 Gbit Ethernet connection an old notebook, and only 100 Mbit on newer faster computer

    - by Sam
    Strange problem about Ethernet speed: recently we bought an i7 core computer running Win7 64 bit with an onboard Gigabit Ethernet controller (Realtek PCIe Gbit Ethernet Family controller). Connecting this new fast pc directly to our brand new ASUS Gigabit Ethernet router via CAT6 cable(!) shows up the adapter status (see picture attached) only 100mbit, while the router is capable of 1000 mbit. More facts: Connecting an 8 year old IBM notebook with gigabit ethernet to the same cable end shows 1.0 Gbit connection in its adapter status. Speedtest.net shows 35 mbit/s down on the new computer Speedtest.net shows 78 mbit/s down on the old rusty IBM notebook. We have an 120 mbit down internet connection, which we we truly receive on another pc (also directly connected to the router) How to get the 1.0 Gbit going in the new pc ?

    Read the article

  • Why, when on Kubuntu I lose internet connection, am I unable to reconnect?

    - by Jonathan
    Using Kubuntu 11.10. Sony Vaio computer. Network controller: Intel Corporation WiFi Link 5100. If I connect to a wireless network, and the signal drops, then I am unable to connect to any network without a reboot. I can assure that the issue has nothing to do with the computer going to sleep, as I have experienced the above while using my computer continuously. Here is exactly what happens: Connect to network (at University, where the connection is not so great). The connection is broken There are three other possible networks available, but none of them can be connected to. I have tried off and on sometimes for hours. I am always able to reestablish a connection after a reboot. I can only think of two explanations. The first is that a temp file is corrupted when the internet connection is abruptly dropped. The second is that my computer actually corrupts something before the loss of internet connection, which causes the loss in signal, and inability to reconnect. However, I am not confident that my explanations are complete, nor do I have any idea how to test these things.

    Read the article

  • Internet unusably slow with Realtek Semiconductor Co., Ltd. RTL8111/8168B card

    - by user42424
    So I have recently installed Ubuntu 11.10 for a dual boot with wind 7. After the install I had like 300 updates, so I installed them. At first I could use the internet, although it was extremely slow. However now I cannot, sometimes it will load and others it will simply time out. When I try to download something it will either take forever or will not at all. This is a wired system. On Windows side my speeds are fine. Any help would be greatly appreciated. Also like I said I am new to Linux/Ubuntu so please be nice. One last thing, I also installed 11.10 for same dual boot on my laptop, and wireless speed is the same as on Windows? Only the wired desktop gives me the problem? Hear is some hardware info.. Hope it helps. Mobo: Gigabyte GA=880GMA- AMD / CPU: AMD Phenom (tm) IIx4 965 / 16 GB Ram / Realtek PCIe GBE Family Controller / Cisco Linksys E2000 / Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) / eth0 Link encap:Ethernet HWaddr 50:e5:49:33:64:cf inet addr:192.168.1.118 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::52e5:49ff:fe33:64cf/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:76722 errors:0 dropped:76722 overruns:0 frame:76722 TX packets:49692 errors:0 dropped:65 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:107956638 (107.9 MB) TX bytes:4342553 (4.3 MB) Interrupt:44 Base address:0x2000 thanks to roadmr problem solved! I powered down PC, un plugged power from pc end, waited a few (maybe 3)minutes. plugged power back in, pushed and held power button for 30 + seconds. Let go, powered on PC, and my Internet is fine! downloads and web speed blaze, just like on my Win 7 boot, maybe even faster. Problem Solved, Thanks to all!! **

    Read the article

  • Windows 7 Intermittent Connection Issues (Continuously "identifying")

    - by andrewktmeikle
    I have an issue solely with my desktop windows 7 machine on my network (the network has multiple different devices, on the same and different operating systems) and the issue is that irregularly, although sometimes frequently, I briefly get disconnected from the internet (briefly is for around 5-10 seconds). However, I never loose the bars on the wifi thing, eg I don't get the yellow triangle, but it goes to the identifying stage and then reconnects. The reason I noticed the problem was when I was streaming music it would stop and I would refresh the page and it would start working again ( turned out it was because it took that amount of time to get connected again). So my question is, what would cause the intermittent issues and start the "identifying" process again. I don't think its my router, because no one else is having problems, so the other option is that its a problem specifically with my machine. I'm connecting to a Netgear DG834GT router, and I'm using a Edimax Wireless-N150 USB Adapter. Anyone have any ideas?

    Read the article

  • Browser keeps being really rude to me today

    - by j-t-s
    Hi All I've had this problem only once before, years ago. I bought a new computer the other day and last night I visited a website which Google Chrome suspected was an insecure site. So I proceeded to view the page anyway (Stupid, I know... But I was curious), and all of a sudden the window closed and ever since, every few minutes either Google chrome or Internet Explorer keeps popping up with random websites, most of which are porn-related sites. I have downloaded ZoneAlarm, IOBit 360, Eset Smart Security and none of them reported any problems. I still have the rube browser problem. Can somebody please suggest any software/ways to fix this? (Other than to reformat please :)) Thank you :)

    Read the article

  • Make all text EXCEPT <input> unselectable in Internet Explorer? [migrated]

    - by Ashli
    I have a website where I want to disable users from selecting content EXCEPT for input areas. I currently have some CSS to disable user-select: -webkit-user-select: none; -khtml-user-select: none; -moz-user-select: none; -o-user-select: none; user-select: none; However, this does NOT cover Internet Explorer; thus, I need to implement some JavaScript: <body onselectstart="return false;"> Through CSS and JavaScript, I can make all content unselectable across all popular browsers. BUT, this code also makes areas unselectable, which is a major case of poor usability. I use CSS to make input areas selectable: -webkit-user-select: text; -khtml-user-select: text; -moz-user-select: text; -o-user-select: text; user-select: text; .. and as you might have expected, this does not cover Internet Explorer, since I used JavaScript to disable all content from being selectable. What can I do to make all content unselectable except for input areas?

    Read the article

  • Find words from a list within a website

    - by Senoculus
    Summary: I need to find out if any items in my list occur in a website. I could do it manually with ctrl+f, but it would take a long time. Description I have a text file with key words in this format: word1 word4 word12 word24 ... I need to search text in a table on a website (in Internet Explorer) with this format: RandomWord version 1.3 ... word1 version 1.3 ... word2 version 2.6 ... word5 version 1.1 ... randomword version 9.0 ... word12 version 1.0 ... ... ... ... If the above data was what I had, it would be nice to end up with this list: word1 word12

    Read the article

  • Access violation when accessing a COM object from .Net

    - by Groo
    Dear Sirs, I am sorry if the post is too long, but I would be happy if someone would at least point read the bolded titles, and point me in the right direction. I am having this problem for couple of days, but was unable to found the answer on the net. These are the things I have found out so far. 1. "Access violation" exception crushes my managed application My C# WinForms app sometimes closes with an "Access violation" exception ("Attempted to read or write protected memory"), right in the moment when selecting a TabPage in a windows form TabControl. From the stack trace (try/catch around Application.Run) I can see that the exception happens at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg), called inside UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(Int32 dwComponentID, Int32 reason, Int32 pvLoopData). -- Message: Attempted to read or write protected memory. This is often an indication that other memory is corrupt. -- Stack trace: at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg) at System.Windows.Forms.Application.ComponentManager .System.Windows.Forms.UnsafeNativeMethods .IMsoComponentManager.FPushMessageLoop (Int32 dwComponentID, Int32 reason, Int32 pvLoopData) at System.Windows.Forms.Application.ThreadContext .RunMessageLoopInner(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.ThreadContext .RunMessageLoop(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.Run(ApplicationContext context) at MyApp.Program.Main() 2. The faulting module seems to be a COM object (ChartFX Client Server 6.2) Using WinDbg (with SoS loaded), I caught it on the unmanaged side, inside ChartFX.ClientServer.Core.dll (that's a COM charting component we are using): (ca84.c98c): Access violation - code c0000005 (first chance) First chance exceptions are reported before any exception handling. This exception may be expected and handled. eax=00000000 ebx=06e67c38 ecx=06e67c38 edx=000018c6 esi=06e7df30 edi=317a9e80 eip=31666110 esp=0015e040 ebp=0015e08c iopl=0 nv up ei pl zr na pe nc cs=001b ss=0023 ds=0023 es=0023 fs=003b gs=0000 efl=00010246 ChartFX_ClientServer_Core!Ordinal5507+0x97b7: 31666110 8a404d mov al,byte ptr [eax+4Dh] ds:0023:0000004d=?? [edit:] I also wasn't able to get the unmamanged stack details from WinDbg (it said "Stack unwind info not available"): 0:000 kP ChildEBP RetAddr WARNING: Stack unwind information not available. Following frames may be wrong. 0015e08c 3166288b ChartFX_ClientServer_Core!Ordinal5507+0x97b7 0015e394 3165a921 ChartFX_ClientServer_Core!Ordinal5507+0x5f32 0015e480 31678685 ChartFX_ClientServer_Core!Ordinal5496+0x26a 0015e568 3167bef4 ChartFX_ClientServer_Core!Ordinal5492+0x975 0015e668 316a356b ChartFX_ClientServer_Core!Ordinal5492+0x41e4 0015e77c 31709496 ChartFX_ClientServer_Core!Ordinal443+0x5745 0015e7d0 31707f70 ChartFX_ClientServer_Core!Ordinal2584+0x3cdc 0015e7f8 3170817d ChartFX_ClientServer_Core!Ordinal2584+0x27b6 0015e81c 3162fd76 ChartFX_ClientServer_Core!Ordinal2584+0x29c3 0015e86c 7719f8d2 ChartFX_ClientServer_Core!Ordinal899+0x6b6 0015e898 7719f794 USER32!GetMessageW+0x93 0015e910 771a06f6 USER32!GetWindowLongW+0x115 0015e940 771a069c USER32!CallWindowProcW+0x75 0015e960 747fcef4 USER32!CallWindowProcW+0x1b 0015e97c 747fd073 comctl32!Ordinal377+0x5c 0015e9e0 747fd027 comctl32!DefSubclassProc+0x92 0015ea04 747fd4e6 comctl32!DefSubclassProc+0x46 0015ea20 747fd073 comctl32!DefSubclassProc+0x505 0015ea84 747fd118 comctl32!DefSubclassProc+0x92 0015eae4 7719f8d2 comctl32!DefSubclassProc+0x137 3. Bug is not easy to reproduce (although it can be provoked usually in less than 5 min.) I have several Chart instances in several TabPages, and this usually happens while I am switching the tabs. I still don't know how to reproduce it, besides switching those tabs for several minutes before it happens, so I cannot use our source control to reliably find the build which didn't have this problem. I am accessing the charts through the managed AxChart wrapper class (derived from AxHost), which was created by VS designer automatically. 4. What should be my next step? If someone could point me to the next step I should do to find the actual cause, I would be very grateful. Experimenting (removing and returning code) does not do much good, because I don't know how to reproduce it, so it would take large amounts of time on each iteration just to convince myself that the bug is still there. I have found that people often suggest something like "switching compiler optimizations", but since the exception is not thrown deterministically, I don't want to simply rearrange some bytes and hope that it never returns. Thanks a lot in advance! Best regards, Groo

    Read the article

  • using return values from a c# .net made component build as com+

    - by YvesR
    Hello, so far I made a component in C# .NET 4 and use System.EnterpriseServices to make it COM visible. I want to develop business methods in C#, but I still need to access them from classic ASP (vbscript). So far so good, everything works fine (exept function overloading :)). Now I made a test class to get more expirience with return code. using System; using System.Collections.Generic; using System.Linq; using System.Text; using System.EnterpriseServices; using System.Management; namespace iController { /// /// The tools class provides additional functions for general use in out of context to other classes of the iController. /// public class tools :ServicedComponent { #region publich methods public bool TestBoolean() { return true; } public string TestString() { return "this is a string"; } public int TestInteger() { return 32; } public double TestDouble() { return 32.32; } public float TestFloat() { float ret = 2 ^ 16; return ret; } public string[] TestArray() { string[] ret = {"0","1"}; return ret; } public int[][] TestJaggedArray() { int[][] jaggedArray = new int[3][]; jaggedArray[0] = new int[] { 1, 3, 5, 7, 9 }; jaggedArray[1] = new int[] { 0, 2, 4, 6 }; jaggedArray[2] = new int[] { 11, 22 }; return jaggedArray; } public Dictionary<string, string> TestDictionary() { Dictionary<string, string> ret = new Dictionary<string,string>(); ret.Add("test1","val1"); ret.Add("test2","val2"); return ret; } #endregion } } Then I just made a simple vbscript file to run it with cscript.exe for testing porpuse. Dim oTools : Set oTools = CreateObject("iController.tools") WScript.StdOut.WriteLine TypeName(oTools.TestBoolean()) & " - " & oTools.TestBoolean() WScript.StdOut.WriteLine TypeName(oTools.TestString()) & " - " & oTools.TestString() WScript.StdOut.WriteLine TypeName(oTools.TestInteger()) & " - " & oTools.TestInteger() WScript.StdOut.WriteLine TypeName(oTools.TestDouble()) & " - " & oTools.TestDouble() WScript.StdOut.WriteLine TypeName(oTools.TestFloat()) & " - " & oTools.TestFloat() test = oTools.TestArray() WScript.StdOut.WriteLine TypeName(test) WScript.StdOut.WriteLine UBound(test) For i = 0 To UBound(test) WScript.StdOut.WriteLine test(i) Next For Each item IN test WScript.StdOut.WriteLine item Next test = oTools.TestJaggedArray() WScript.StdOut.WriteLine TypeName(test) For Each item IN test WScript.StdOut.WriteLine test & " - " & test.Item(item) Next test = oTools.TestDictionary() WScript.StdOut.WriteLine TypeName(test) For Each item IN test WScript.StdOut.WriteLine test & " - " & test.Item(item) Next What works fine: string, int, foat, double When it comes to array, jaggedarray or dictionaries I get a type mismatch. VarType is 13 object for the dictionary e.g. but this dict seems to be different then the Scripting.Dictionary. I checked codeproject.com and stackoverflow all day and didn't find any hints exept some thread on stackoverflow where someone mentioned there is a need to created a IDispatch interface. So anyone ever had the same issue and can help me or give me some hints I can go on with?

    Read the article