Search Results

Search found 9122 results on 365 pages for 'sound card'.

Page 349/365 | < Previous Page | 345 346 347 348 349 350 351 352 353 354 355 356  | Next Page >

  • compile lastest bnx2 driver on debian squeeze

    - by markus
    I want to upgrade the bnx2 network card driver in a Dell Power Edge R410. I downloaded the latest driver version from the broadcom website. If I want to compile the driver it fails with the following errors: make make -C bnx2/src KVER=2.6.32-5-amd64 PREFIX= make[1]: Entering directory `/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src' make -C /lib/modules/2.6.32-5-amd64/build SUBDIRS=/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src modules make[2]: Entering directory `/usr/src/linux-headers-2.6.32-5-amd64' Building modules, stage 2. MODPOST 2 modules make[2]: Leaving directory `/usr/src/linux-headers-2.6.32-5-amd64' make[1]: Leaving directory `/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src' make -C bnx2x/src KVER=2.6.32-5-amd64 PREFIX= make[1]: Entering directory `/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src' make -C /lib/modules/2.6.32-5-amd64/build M=`pwd` modules make[2]: Entering directory `/usr/src/linux-headers-2.6.32-5-amd64' CC [M] /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.o In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1009:1: error: "PCI_VPD_LRDT_ID_STRING" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1327:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1011:1: error: "PCI_VPD_LRDT_RO_DATA" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1328:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1013:1: error: "PCI_VPD_LRDT_RW_DATA" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1329:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1019:1: error: "PCI_VPD_SRDT_END" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1334:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1032: error: conflicting types for ‘pci_vpd_lrdt_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1355: error: previous definition of ‘pci_vpd_lrdt_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1037: error: conflicting types for ‘pci_vpd_srdt_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1366: error: previous definition of ‘pci_vpd_srdt_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1042: error: conflicting types for ‘pci_vpd_find_tag’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1391: error: previous declaration of ‘pci_vpd_find_tag’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1077: error: conflicting types for ‘pci_vpd_info_field_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1377: error: previous definition of ‘pci_vpd_info_field_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1082: error: conflicting types for ‘pci_vpd_find_info_keyword’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1403: error: previous declaration of ‘pci_vpd_find_info_keyword’ was here make[5]: *** [/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.o] Fehler 1 make[4]: *** [_module_/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src] Fehler 2 make[3]: *** [sub-make] Fehler 2 make[2]: *** [all] Fehler 2 make[2]: Leaving directory `/usr/src/linux-headers-2.6.32-5-amd64' make[1]: *** [bnx2x.o] Fehler 2 make[1]: Leaving directory `/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src' make: *** [l2build] Fehler 2

    Read the article

  • BluRay audio/video stuttering with PowerDVD 11, WinDVD 11 Pro, etc? Xonar/Auzen HD audio option?

    - by jrista
    I recently upgraded my Windows 7 MediaCenter HTPC due to a motherboard failure (really old motherboard and cpu, it was on its last legs.) I chose to upgrade to an i5 system with everything built into the motherboard. I did my due diligence, researched, and found some hardware that was within my budget. I ended up with: Core i5 2500K (3.3Ghz) Corsair XMS3 2x2Gb DDR3 (4Gb) ASUS P8H 61-M LE/CSM MicroCenter 64Gb SSD (Previous BluRay player, forget the brand) The system is pretty awesome, and plays everything I have perfectly. I almost went with an Atom solution, however there have been numerous notes that they do not play NetFlix Instant Watch well...and I am a heavy Netflix IW user. High definition BluRay rips work well, although they usually contain lower audio quality than the BluRay's they were ripped from. The real problem I am encountering is playing back BluRay video from discs. For some reason, I am encountering rather terrible stuttering problems with both the audio and video. The stuttering is synchronous in both, and occurs at seemingly random intervals. I've used PowerDVD 9, PowerDVD 11 trial, and WinDVD 11 Pro trial. All three have stuttering problems, although PowerDVD 11 seems to have the least. Watching system resource usage, CPU load is never above 20%, and memory usage tends to be a constant 1/3rd the total available system memory. When playback is fine, its superb...the video is crystal clear. The audio quality is ok, certainly not what I would expect from a BluRay disc. I did some research, and it seems that playing BluRay from a PC causes a downsampling of the audio? I am curious if the audio is my primary problem here, the cause of the stuttering I am encountering? When stuttering occurs, the audio gets REALLY bad, while the video just pauses momentarily every second until for whatever reason everything picks up and runs fine (usually after a few seconds to a couple minutes.) The audio chipset is a Realtek HD ALC887 8-channel, supposedly designed to support BluRay playback. Has anyone encountered any issues like this playing back bluray discs on a PC (namely with PowerDVD...WinDVD was FAR worse, and seemed to have real trouble even reading the discs, and I have no interest in fiddling with it further.) Is there any reason to suspect the video decoding as the problem?(Given how bad the audio gets during a stutter, and how clean the video remains, I am inclined to think the issue boils down to audio.) Is it even remotely possible that the motherboard, cpu, or ram are causing the stuttering (all three are pretty blazing fast...faster than the hardware that I replaced, which seemed to play BluRay fine with PowerDVD 9.) I've read a bit about the Asus Xonar HDAV 1.3 and the Auzen X-Fi HomeTheater HD home theater hi-fi audio cards. Seems they are the only way to get true full-quality, uncompressed BluRay audio bitstreaming over HDMI on a PC. None of the usual suspects seem to have these cards in stock, however. Are these cards worth getting? Are they even still available, or have they been discontinued (if so, that would indeed be sad...they sound simply fantastic.)

    Read the article

  • Does this prove a network bandwidth bottleneck?

    - by Yuji Tomita
    I've incorrectly assumed that my internal AB testing means my server can handle 1k concurrency @3k hits per second. My theory at at the moment is that the network is the bottleneck. The server can't send enough data fast enough. External testing from blitz.io at 1k concurrency shows my hits/s capping off at 180, with pages taking longer and longer to respond as the server is only able to return 180 per second. I've served a blank file from nginx and benched it: it scales 1:1 with concurrency. Now to rule out IO / memcached bottlenecks (nginx normally pulls from memcached), I serve up a static version of the cached page from the filesystem. The results are very similar to my original test; I'm capped at around 180 RPS. Splitting the HTML page in half gives me double the RPS, so it's definitely limited by the size of the page. If I internally ApacheBench from the local server, I get consistent results of around 4k RPS on both the Full Page and the Half Page, at high transfer rates. Transfer rate: 62586.14 [Kbytes/sec] received If I AB from an external server, I get around 180RPS - same as the blitz.io results. How do I know it's not intentional throttling? If I benchmark from multiple external servers, all results become poor which leads me to believe the problem is in MY servers outbound traffic, not a download speed issue with my benchmarking servers / blitz.io. So I'm back to my conclusion that my server can't send data fast enough. Am I right? Are there other ways to interpret this data? Is the solution/optimization to set up multiple servers + load balancing that can each serve 180 hits per second? I'm quite new to server optimization, so I'd appreciate any confirmation interpreting this data. Outbound traffic Here's more information about the outbound bandwidth: The network graph shows a maximum output of 16 Mb/s: 16 megabits per second. Doesn't sound like much at all. Due to a suggestion about throttling, I looked into this and found that linode has a 50mbps cap (which I'm not even close to hitting, apparently). I had it raised to 100mbps. Since linode caps my traffic, and I'm not even hitting it, does this mean that my server should indeed be capable of outputting up to 100mbps but is limited by some other internal bottleneck? I just don't understand how networks at this large of a scale work; can they literally send data as fast as they can read from the HDD? Is the network pipe that big? In conclusion 1: Based on the above, I'm thinking I can definitely raise my 180RPS by adding an nginx load balancer on top of a multi nginx server setup at exactly 180RPS per server behind the LB. 2: If linode has a 50/100mbit limit that I'm not hitting at all, there must be something I can do to hit that limit with my single server setup. If I can read / transmit data fast enough locally, and linode even bothers to have a 50mbit/100mbit cap, there must be an internal bottleneck that's not allowing me to hit those caps that I'm not sure how to detect. Correct? I realize the question is huge and vague now, but I'm not sure how to condense it. Any input is appreciated on any conclusion I've made.

    Read the article

  • Bridged virtual interface is not available or visible to ifconfig.

    - by Omniwombat
    Hello all. I'm running Ubuntu 9.04, kernel 2.6.28-18, and vmware-server 2.0.1. I'm attempting to setup a virtual linux machine to use a bridged interface rather than NAT or host-only. Both NAT and host-only work just fine. When running vmware-config.pl, I set /dev/vmnet0 to bridge eth0, /dev/vmnet1 to host-only, and /dev/vmnet8 to NAT. When I run ifconfig -a I see the physical interface (eth0), vmnet1 and vmnet8 both of which are up and have IP addresses assigned to them. I also see other various interfaces that are not relevant here. In the web console, when I ask that the guest machine's network card be bridged, it states that a bridged setup is "Not available" and shows the disabled device icon. Inside the guest machine, I do have an eth0 interface which I can set to anything I like, however it can't see my external network, or the host. I do see errors in my vmware/hostd.log which state: "The network bridge on device vmnet0 is not running. The virtual machine will not be able to communicate with the host or with other machines on your network" which confirms the problem. vmnet-bridge is running, and I see the following in my process table: /usr/bin/vmnet-bridge -d /var/run/vmnet-bridge-0.pid -n 0 -i eth0 I confirm that the /var/run/vmnet-bridge-0.pid file is there and that it points to the correct process. I saw this question relating to Ubuntu 9.04 and bridged interfaces, in which the poster determined that the vsock library was not getting built due to a flaw in the vmware-config.pl script. I applied the patch, reran the script, and confirm that vsock.ko and vsock.o are in my /lib directory structure. vsock does show up in an lsmod. My /etc/vmware directory has /vmnet1 and /vmnet8 subdirectories. They contain configuration utilities for running DHCP and nat type services as expected. There is no vmnet0 subdirectory. My /etc/vmware/netmap.conf file DOES show entries for vmnet0; both the name and the device as I configured it from the script. My /dev directory contains devices vmnet0 through vmnet9. They have major device number 119, and minor device numbers 0 through 9. /proc/net/dev shows statistics for vmnet1 and vmnet8, but not vmnet0. I have a /proc/vmnet directory, but it's empty. When I start or stop the vmware service with /etc/init.d/vmware start, I see the following: Starting VMware services: Virtual machine monitor done Virtual machine communication interface done VM communication interface socket family: done Virtual ethernet done Bridged networking on /dev/vmnet0 done Host-only networking on /dev/vmnet1 (background) done DHCP server on /dev/vmnet1 done Host-only networking on /dev/vmnet8 (background) done DHCP server on /dev/vmnet8 done NAT service on /dev/vmnet8 done VMware Server Authentication Daemon (background) done Shared Memory Available done Starting VMware management services: VMware Server Host Agent (background) done VMware Virtual Infrastructure Web Access Starting VMware autostart virtual machines: Virtual machines done Nothing appears to be wrong there. What n00b thing am I doing such that vmnet0 and only vmnet0 does not show up in the interface list?

    Read the article

  • ubuntu 10.04; kvm bridged networking not working with public ip addresses

    - by senorsmile
    I have a dedicated hosted server box with ubuntu 10.04 64 bit installed. I would like to run kvm with ubuntu 8.04 installed for some php 5.2 compatible apps(they don't work right with php 5.3, the default in ubuntu 10.04). I installed KVM as instructed at https://help.ubuntu.com/community/KVM/Installation . I installed the vm using virt-manager. I never could figure out how use virt-install or any of those automated installers. I just installed it using the disc. I set up bridged networking as per https://help.ubuntu.com/community/KVM/Networking . However, the bridged connection doesn't work. Here's my /etc/network/interfaces on the host, running ubuntu 10.04. (with specific public ip blanked) auto lo iface lo inet loopback auto eth0 iface eth0 inet manual auto br0 iface br0 inet static address xx.xx.xx.xx netmask 255.255.255.248 gateway xx.xx.xx.xa bridge_ports eth0 bridge_stp on bridge_fd 0 bridge_maxwait 10 ` Here's my /etc/network/interfaces on the guest, running ubuntu 8.04. auto lo iface lo inet loopback auto eth0 iface eth0 inet static address xx.xx.xx.xy netmask 255.255.255.248 gateway xx.xx.xx.xa The two vm's can communicate to each other. But, the guest vm can't access anyone in the real world. Here's my /etc/libvirt/qemu/store_804.xml <domain type='kvm'> <name>store_804</name> <uuid>27acfb75-4f90-a34c-9a0b-70a6927ae84c</uuid> <memory>2097152</memory> <currentMemory>2097152</currentMemory> <vcpu>2</vcpu> <os> <type arch='x86_64' machine='pc-0.12'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/bin/kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/var/lib/libvirt/images/store_804.img'/> <target dev='hda' bus='ide'/> </disk> <disk type='block' device='cdrom'> <driver name='qemu' type='raw'/> <target dev='hdc' bus='ide'/> <readonly/> </disk> <interface type='bridge'> <mac address='52:54:00:26:0b:c6'/> <source bridge='br0'/> <model type='virtio'/> </interface> <console type='pty'> <target port='0'/> </console> <console type='pty'> <target port='0'/> </console> <input type='mouse' bus='ps2'/> <graphics type='vnc' port='-1' autoport='yes'/> <sound model='es1370'/> <video> <model type='cirrus' vram='9216' heads='1'/> </video> </devices> </domain> Any idea where I've gone wrong?

    Read the article

  • Linux Kernel not passing through multicast UDP packets

    - by buecking
    Recently I've set up a new Ubuntu Server 10.04 and noticed my UDP server is no longer able to see any multicast data sent to the interface, even after joining the multicast group. I've got the exact same set up on two other Ubuntu 8.04.4 LTS machines and there is no problem receiving data after joining the same multicast group. The ethernet card is a Broadcom netXtreme II BCM5709 and the driver used is: b $ ethtool -i eth1 driver: bnx2 version: 2.0.2 firmware-version: 5.0.11 NCSI 2.0.5 bus-info: 0000:01:00.1 I'm using smcroute to manage my multicast registrations. b$ smcroute -d b$ smcroute -j eth1 233.37.54.71 After joining the group ip maddr shows the newly added registration. b$ ip maddr 1: lo inet 224.0.0.1 inet6 ff02::1 2: eth0 link 33:33:ff:40:c6:ad link 01:00:5e:00:00:01 link 33:33:00:00:00:01 inet 224.0.0.1 inet6 ff02::1:ff40:c6ad inet6 ff02::1 3: eth1 link 01:00:5e:25:36:47 link 01:00:5e:25:36:3e link 01:00:5e:25:36:3d link 33:33:ff:40:c6:af link 01:00:5e:00:00:01 link 33:33:00:00:00:01 inet 233.37.54.71 <------- McastGroup. inet 224.0.0.1 inet6 ff02::1:ff40:c6af inet6 ff02::1 So far so good, I can see that I'm receiving data for this multicast group. b$ sudo tcpdump -i eth1 -s 65534 host 233.37.54.71 tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on eth1, link-type EN10MB (Ethernet), capture size 65534 bytes 09:30:09.924337 IP 192.164.1.120.58848 > 233.37.54.71.15572: UDP, length 212 09:30:09.947547 IP 192.164.1.120.58848 > 233.37.54.71.15572: UDP, length 212 09:30:10.108378 IP 192.164.1.120.58866 > 233.37.54.71.15574: UDP, length 268 09:30:10.196841 IP 192.164.1.120.58848 > 233.37.54.71.15572: UDP, length 212 ... I can also confirm that the interface is receiving mcast packets. b $ ethtool -S eth1 | grep mcast_pack rx_mcast_packets: 103998 tx_mcast_packets: 33 Now here's the problem. When I try to capture the traffic using a simple ruby UDP server I receive zero data! Here's a simple server that reads data send on port 15572 and prints the first two characters. This works on the two 8.04.4 Ubuntu Servers, but not the 10.04 server. require 'socket' s = UDPSocket.new s.bind("", 15572) 5.times do text, sender = s.recvfrom(2) puts text end If I send a UDP packet crafted in ruby to localhost, the server receives it and prints out the first two characters. So I know that the server above is working correctly. irb(main):001:0> require 'socket' => true irb(main):002:0> s = UDPSocket.new => #<UDPSocket:0x7f3ccd6615f0> irb(main):003:0> s.send("I2 XXX", 0, 'localhost', 15572) When I check the protocol statistics I see that InMcastPkts is not increasing. While on the other 8.04 servers, on the same network, received a few thousands packets in 10 seconds. b $ netstat -sgu ; sleep 10 ; netstat -sgu IcmpMsg: InType3: 11 OutType3: 11 Udp: 446 packets received 4 packets to unknown port received. 0 packet receive errors 461 packets sent UdpLite: IpExt: InMcastPkts: 4654 <--------- Same as below OutMcastPkts: 3426 InBcastPkts: 9854 InOctets: -1691733021 OutOctets: 51187936 InMcastOctets: 145207 OutMcastOctets: 109680 InBcastOctets: 1246341 IcmpMsg: InType3: 11 OutType3: 11 Udp: 446 packets received 4 packets to unknown port received. 0 packet receive errors 461 packets sent UdpLite: IpExt: InMcastPkts: 4656 <-------------- Same as above OutMcastPkts: 3427 InBcastPkts: 9854 InOctets: -1690886265 OutOctets: 51188788 InMcastOctets: 145267 OutMcastOctets: 109712 InBcastOctets: 1246341 If I try forcing the interface into promisc mode nothing changes. At this point I'm stuck. I've confirmed the kernel config has multicast enabled. Perhaps there are other config options I should be checking? b $ grep CONFIG_IP_MULTICAST /boot/config-2.6.32-23-server CONFIG_IP_MULTICAST=y Any thoughts on where to go from here?

    Read the article

  • Application Does Not Start in Windows 7

    - by Jim Fell
    I recently installed a new 60GB SSD as my primary hard drive and re-installed Windows 7 Professional 64-bit. I then installed SSD Fresh from Abelssoft to optimize Windows to run on the SSD. It seemed to install okay, but when I try to run the utility, its splash screen appears briefly before it quietly closes. No errors are displayed; the utility just fails to launch. I have run SSD Fresh on another SSD-equipped Windows 7 Pro x64 computer in the past without any problems. Does anyone know what might be preventing the program from running? I tried running sfc /scannow from the command line (with administrator privileges), shutting down the Spybot Resident, and disabling the firewall and virus scanner. I also tried running the tool as administrator; I even tried reinstalling it, running the installer as administrator. No luck. Every time I try to launch the program the Event Viewer logs this same set of errors: Error 4/2/2012 11:35:44 PM Application Error 1000 (100) Faulting application name: SSDFresh.exe, version: 1.0.0.0, time stamp: 0x4f2a45d8 Faulting module name: unknown, version: 0.0.0.0, time stamp: 0x00000000 Exception code: 0xc0000005 Fault offset: 0x000007ff0016dbba Faulting process id: 0x994 Faulting application start time: 0x01cd11fd9fe978df Faulting application path: C:\Program Files (x86)\SSD Fresh\SSDFresh.exe Faulting module path: unknown Report Id: dfeed551-7df0-11e1-a2c7-002522c47ec0 Error 4/2/2012 11:35:43 PM .NET Runtime 1026 None Application: SSDFresh.exe Framework Version: v4.0.30319 Description: The process was terminated due to an unhandled exception. Exception Info: System.NullReferenceException Stack: at AbBugReporter.BugForm.InitLanguage() at AbBugReporter.BugForm..ctor(AbFlexTrans.LanguageInfo, AbBugReporter.BugReportManager, Boolean) at AbBugReporter.BugReportManager.Show(System.Exception) at SSDFresh.App.App_DispatcherUnhandledException(System.Object, System.Windows.Threading.DispatcherUnhandledExceptionEventArgs) at System.Windows.Threading.Dispatcher.CatchException(System.Exception) at MS.Internal.Threading.ExceptionFilterHelper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.Dispatcher.WrappedInvoke(System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.Dispatcher.InvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32) at MS.Win32.HwndSubclass.SubclassWndProc(IntPtr, Int32, IntPtr, IntPtr) at MS.Win32.UnsafeNativeMethods.DispatchMessage(System.Windows.Interop.MSG ByRef) at System.Windows.Threading.Dispatcher.PushFrameImpl(System.Windows.Threading.DispatcherFrame) at System.Windows.Application.RunInternal(System.Windows.Window) at System.Windows.Application.Run() at SSDFresh.App.Main() Error 4/2/2012 11:35:39 PM SideBySide 59 None Activation context generation failed for "C:\Windows\Microsoft.NET\Framework64\v4.0.30319\csc.exe".Error in manifest or policy file "C:\Windows\Microsoft.NET\Framework64\v4.0.30319\csc.exe.Config" on line 0. Invalid Xml syntax. Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None For those who are interested, here is my system configuration: ASRock M3A770DE AM3 AMD 770 ATX AMD Motherboard AMD Athlon II X3 455 Rana 3.3GHz Socket AM3 95W Triple-Core Desktop Processor ADX455WFGMBOX G.SKILL Value Series 8GB (2 x 4GB) 240-Pin DDR3 SDRAM DDR3 1333 (PC3 10600) Desktop Memory Model F3-10600CL9D-8GBNT Mushkin Enhanced Chronos Deluxe MKNSSDCR60GB-DX 2.5" 60GB SATA III Synchronous MLC Internal Solid State Drive (SSD) (Primary/Boot HD) Western Digital Caviar Blue RFHWD1600AAJS 160GB 7200 RPM SATA 3.0Gb/s 3.5" Internal Hard Drive -Bare Drive (Secondary HD) Sony Optiarc CD/DVD Burner Black SATA Model AD-7261S-0B LightScribe Support RAIDMAX RX-850AE 850W ATX12V v2.3 / EPS12V SLI Certified CrossFire Ready 80 PLUS GOLD Certified Modular Active PFC Power Supply ASUS HD7850-DC2-2GD5 Radeon HD 7850 2GB 256-bit GDDR5 PCI Express 3.0 x16 HDCP Ready CrossFireX Support Video Card Asus ML228H 21.5" Full HD LED BackLight LED Monitor Slim Design (x3)

    Read the article

  • SSH Public Key Authentication only works if active session exists before

    - by Webx10
    I have a rather strange problem with my SSH configuration. I set up my server with the help of a Remote Access Card and configured everything with a KVM viewer. So while being logged into the server via the KVM Viewer I configured SSH with only pubkey and tried to login from my local laptop. It worked fine. If I quit the KVM Session (or logout with the user in the KVM session) I cannot login via ssh anymore (pubkey denied). SSH login only works as long as the user is somewhere still logged in. Any hints what the problem might be? Console output for a failed login (all personal data exchanged): OpenSSH_6.2p2, OSSLShim 0.9.8r 8 Dec 2011 debug1: Reading configuration data /Users/mylocaluser/.ssh/config debug1: Reading configuration data /etc/ssh_config debug1: /etc/ssh_config line 20: Applying options for * debug1: /etc/ssh_config line 103: Applying options for * debug1: Connecting to 100.100.100.100 [100.100.100.100] port 12345. debug1: Connection established. debug1: identity file /Users/mylocaluser/.ssh/id_rsa type 1 debug1: identity file /Users/mylocaluser/.ssh/id_rsa-cert type -1 debug1: identity file /Users/mylocaluser/.ssh/id_dsa type -1 debug1: identity file /Users/mylocaluser/.ssh/id_dsa-cert type -1 debug1: Enabling compatibility mode for protocol 2.0 debug1: Local version string SSH-2.0-OpenSSH_6.2 debug1: Remote protocol version 2.0, remote software version OpenSSH_6.6.1p1 Ubuntu-2ubuntu2 debug1: match: OpenSSH_6.6.1p1 Ubuntu-2ubuntu2 pat OpenSSH* debug1: SSH2_MSG_KEXINIT sent debug1: SSH2_MSG_KEXINIT received debug1: kex: server->client aes128-ctr [email protected] none debug1: kex: client->server aes128-ctr [email protected] none debug1: SSH2_MSG_KEX_DH_GEX_REQUEST(1024<1024<8192) sent debug1: expecting SSH2_MSG_KEX_DH_GEX_GROUP debug1: SSH2_MSG_KEX_DH_GEX_INIT sent debug1: expecting SSH2_MSG_KEX_DH_GEX_REPLY debug1: Server host key: RSA ab:12:23:34:45:56:67:78:89:90:12:23:34:45:56:67 debug1: Host '[100.100.100.100]:12345' is known and matches the RSA host key. debug1: Found key in /Users/mylocaluser/.ssh/known_hosts:36 debug1: ssh_rsa_verify: signature correct debug1: SSH2_MSG_NEWKEYS sent debug1: expecting SSH2_MSG_NEWKEYS debug1: SSH2_MSG_NEWKEYS received debug1: Roaming not allowed by server debug1: SSH2_MSG_SERVICE_REQUEST sent debug1: SSH2_MSG_SERVICE_ACCEPT received debug1: Authentications that can continue: publickey debug1: Next authentication method: publickey debug1: Offering RSA public key: /Users/mylocaluser/.ssh/id_rsa debug1: Authentications that can continue: publickey debug1: Offering RSA public key: /Users/mylocaluser/.ssh/id_rsa2 debug1: Authentications that can continue: publickey debug1: Trying private key: /Users/mylocaluser/.ssh/id_dsa debug1: No more authentication methods to try. Permission denied (publickey). Console output for a successfull login (only possible while "active session" exists): OpenSSH_6.2p2, OSSLShim 0.9.8r 8 Dec 2011 debug1: Reading configuration data /Users/mylocaluser/.ssh/config debug1: Reading configuration data /etc/ssh_config debug1: /etc/ssh_config line 20: Applying options for * debug1: /etc/ssh_config line 103: Applying options for * debug1: Connecting to 100.100.100.100 [100.100.100.100] port 12345. debug1: Connection established. debug1: identity file /Users/mylocaluser/.ssh/id_rsa type 1 debug1: identity file /Users/mylocaluser/.ssh/id_rsa-cert type -1 debug1: identity file /Users/mylocaluser/.ssh/id_dsa type -1 debug1: identity file /Users/mylocaluser/.ssh/id_dsa-cert type -1 debug1: Enabling compatibility mode for protocol 2.0 debug1: Local version string SSH-2.0-OpenSSH_6.2 debug1: Remote protocol version 2.0, remote software version OpenSSH_6.6.1p1 Ubuntu-2ubuntu2 debug1: match: OpenSSH_6.6.1p1 Ubuntu-2ubuntu2 pat OpenSSH* debug1: SSH2_MSG_KEXINIT sent debug1: SSH2_MSG_KEXINIT received debug1: kex: server->client aes128-ctr [email protected] none debug1: kex: client->server aes128-ctr [email protected] none debug1: SSH2_MSG_KEX_DH_GEX_REQUEST(1024<1024<8192) sent debug1: expecting SSH2_MSG_KEX_DH_GEX_GROUP debug1: SSH2_MSG_KEX_DH_GEX_INIT sent debug1: expecting SSH2_MSG_KEX_DH_GEX_REPLY debug1: Server host key: RSA ab:12:23:34:45:56:67:78:89:90:12:23:34:45:56:67 debug1: Host '[100.100.100.100]:12345' is known and matches the RSA host key. debug1: Found key in /Users/mylocaluser/.ssh/known_hosts:36 debug1: ssh_rsa_verify: signature correct debug1: SSH2_MSG_NEWKEYS sent debug1: expecting SSH2_MSG_NEWKEYS debug1: SSH2_MSG_NEWKEYS received debug1: Roaming not allowed by server debug1: SSH2_MSG_SERVICE_REQUEST sent debug1: SSH2_MSG_SERVICE_ACCEPT received debug1: Authentications that can continue: publickey debug1: Next authentication method: publickey debug1: Offering RSA public key: /Users/mylocaluser/.ssh/id_rsa debug1: Server accepts key: pkalg ssh-rsa blen 279 debug1: Authentication succeeded (publickey). Authenticated to 100.100.100.100 ([100.100.100.100]:12345). debug1: channel 0: new [client-session] debug1: Requesting [email protected] debug1: Entering interactive session. debug1: Sending environment. debug1: Sending env LANG = de_DE.UTF-8 Welcome to Ubuntu 14.04.1 LTS

    Read the article

  • hostapd running on Ubuntu Server 13.04 only allows single station to connect when using wpa

    - by user450688
    Problem Only a single station can connect to hostapd at a time. Any single station can connect (W8, OSX, iOS, Nexus) but when two or more hosts are connected at the same time the first client loses its connectivity. However there are no connectivity issues when WPA is not used. Setup Linux (Ubuntu server 13.04) wireless router (with separate networks for wired WAN, wired LAN, and Wireless LAN. iptables-save output: *nat :PREROUTING ACCEPT [0:0] :INPUT ACCEPT [0:0] :OUTPUT ACCEPT [0:0] :POSTROUTING ACCEPT [0:0] -A POSTROUTING -s 10.0.0.0/24 -o p4p1 -j MASQUERADE -A POSTROUTING -s 10.0.1.0/24 -o p4p1 -j MASQUERADE COMMIT *mangle :PREROUTING ACCEPT [13:916] :INPUT ACCEPT [9:708] :FORWARD ACCEPT [4:208] :OUTPUT ACCEPT [9:3492] :POSTROUTING ACCEPT [13:3700] COMMIT *filter :INPUT DROP [0:0] :FORWARD DROP [0:0] :OUTPUT ACCEPT [9:3492] -A INPUT -i p4p1 -m state --state RELATED,ESTABLISHED -j ACCEPT -A INPUT -i p4p1 -p tcp -m tcp --dport 22 -m state --state NEW -j ACCEPT -A INPUT -i eth0 -j ACCEPT -A INPUT -i wlan0 -j ACCEPT -A INPUT -i lo -j ACCEPT -A FORWARD -i p4p1 -m state --state RELATED,ESTABLISHED -j ACCEPT -A FORWARD -i eth0 -j ACCEPT -A FORWARD -i wlan0 -j ACCEPT -A FORWARD -i lo -j ACCEPT COMMIT /etc/hostapd/hostapd.conf #Wireless Interface interface=wlan0 driver=nl80211 ssid=<removed> hw_mode=g channel=6 max_num_sta=15 auth_algs=3 ieee80211n=1 wmm_enabled=1 wme_enabled=1 #Configure Hardware Capabilities of Interface ht_capab=[HT40+][SMPS-STATIC][GF][SHORT-GI-20][SHORT-GI-40][RX-STBC12] #Accept all MAC address macaddr_acl=0 #Shared Key Authentication wpa=1 wpa_passphrase=<removed> wpa_key_mgmt=WPA-PSK wpa_pairwise=CCMP rsn_pairwise=CCMP ###IPad Connectivevity Repair ieee8021x=0 eap_server=0 Wireless Card #lshw output product: RT2790 Wireless 802.11n 1T/2R PCIe vendor: Ralink corp. physical id: 0 bus info: pci@0000:03:00.0 logical name: mon.wlan0 version: 00 serial: <removed> width: 32 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list logical wireless ethernet physical configuration: broadcast=yes driver=rt2800pci driverversion=3.8.0-25-generic firmware=0.34 ip=10.0.1.254 latency=0 link=yes multicast=yes wireless=IEEE 802.11bgn #iw list output Band 1: Capabilities: 0x272 HT20/HT40 Static SM Power Save RX Greenfield RX HT20 SGI RX HT40 SGI RX STBC 2-streams Max AMSDU length: 3839 bytes No DSSS/CCK HT40 Maximum RX AMPDU length 65535 bytes (exponent: 0x003) Minimum RX AMPDU time spacing: 2 usec (0x04) HT RX MCS rate indexes supported: 0-15, 32 TX unequal modulation not supported HT TX Max spatial streams: 1 HT TX MCS rate indexes supported may differ Frequencies: * 2412 MHz [1] (27.0 dBm) * 2417 MHz [2] (27.0 dBm) * 2422 MHz [3] (27.0 dBm) * 2427 MHz [4] (27.0 dBm) * 2432 MHz [5] (27.0 dBm) * 2437 MHz [6] (27.0 dBm) * 2442 MHz [7] (27.0 dBm) * 2447 MHz [8] (27.0 dBm) * 2452 MHz [9] (27.0 dBm) * 2457 MHz [10] (27.0 dBm) * 2462 MHz [11] (27.0 dBm) * 2467 MHz [12] (disabled) * 2472 MHz [13] (disabled) * 2484 MHz [14] (disabled) Bitrates (non-HT): * 1.0 Mbps * 2.0 Mbps (short preamble supported) * 5.5 Mbps (short preamble supported) * 11.0 Mbps (short preamble supported) * 6.0 Mbps * 9.0 Mbps * 12.0 Mbps * 18.0 Mbps * 24.0 Mbps * 36.0 Mbps * 48.0 Mbps * 54.0 Mbps max # scan SSIDs: 4 max scan IEs length: 2257 bytes Coverage class: 0 (up to 0m) Supported Ciphers: * WEP40 (00-0f-ac:1) * WEP104 (00-0f-ac:5) * TKIP (00-0f-ac:2) * CCMP (00-0f-ac:4) Available Antennas: TX 0 RX 0 Supported interface modes: * IBSS * managed * AP * AP/VLAN * WDS * monitor * mesh point software interface modes (can always be added): * AP/VLAN * monitor valid interface combinations: * #{ AP } <= 8, total <= 8, #channels <= 1 Supported commands: * new_interface * set_interface * new_key * new_beacon * new_station * new_mpath * set_mesh_params * set_bss * authenticate * associate * deauthenticate * disassociate * join_ibss * join_mesh * set_tx_bitrate_mask * set_tx_bitrate_mask * action * frame_wait_cancel * set_wiphy_netns * set_channel * set_wds_peer * Unknown command (84) * Unknown command (87) * Unknown command (85) * Unknown command (89) * Unknown command (92) * testmode * connect * disconnect Supported TX frame types: * IBSS: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * managed: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * AP: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * AP/VLAN: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * mesh point: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * P2P-client: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * P2P-GO: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * Unknown mode (10): 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 Supported RX frame types: * IBSS: 0x40 0xb0 0xc0 0xd0 * managed: 0x40 0xd0 * AP: 0x00 0x20 0x40 0xa0 0xb0 0xc0 0xd0 * AP/VLAN: 0x00 0x20 0x40 0xa0 0xb0 0xc0 0xd0 * mesh point: 0xb0 0xc0 0xd0 * P2P-client: 0x40 0xd0 * P2P-GO: 0x00 0x20 0x40 0xa0 0xb0 0xc0 0xd0 * Unknown mode (10): 0x40 0xd0 Device supports RSN-IBSS. HT Capability overrides: * MCS: ff ff ff ff ff ff ff ff ff ff * maximum A-MSDU length * supported channel width * short GI for 40 MHz * max A-MPDU length exponent * min MPDU start spacing Device supports TX status socket option. Device supports HT-IBSS.

    Read the article

  • How to get ISA 2006 Web Proxy to work with the Single Network Adapter template

    - by tronda
    I need to test an issue with running our application behind a proxy server with different type of configurations, so I installed ISA 2006 Enterprise on a desktop computer. Since this computer only has a single network card and I want to start out easy, I chose the "Single Network Adapter" template. We have a internal NAT'ed network which is in the 10 range. I have defined the internal network on the ISA server to be 10.XXX.YY.1 - 10.XXX.YY.255 I also have the Default rule which denies all traffic, but I've added the following Rule: Policy - Protocols - From - To Accept HTTP Internal External HTTPS Local Host Internal HTTS Server Localhost Then I configured Internet Explorer on a virutal machine running XP within virtualbox with Brigded network (gets same network address range as regular computers on our network) similar to this Instead of the server name I used the IP address. When I try to access a web page, this doesn't go through and I get the following log messages on the proxy server: Original Client IP Client Agent Authenticated Client Service Referring Server Destination Host Name Transport HTTP Method MIME Type Object Source Source Proxy Destination Proxy Bidirectional Client Host Name Filter Information Network Interface Raw IP Header Raw Payload GMT Log Time Source Port Processing Time Bytes Sent Bytes Received Cache Information Error Information Authentication Server Log Time Client IP Destination IP Destination Port Protocol Action Rule Result Code HTTP Status Code Client Username Source Network Destination Network URL Server Name Log Record Type 10.XXX.YY.174 - TCP - - - 24.08.2010 13:25:24 1080 0 0 0 0x0 0x0 - 24.08.2010 06:25:24 10.XXX.YY.174 10.XXX.YY.175 80 HTTP Initiated Connection MyHTTPAccess 0x0 ERROR_SUCCESS Internal Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:24 2275 0 0 0 0x0 0x0 - 24.08.2010 06:25:24 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Initiated Connection 0x0 ERROR_SUCCESS Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:25 2275 0 0 0 0x0 0x0 - 24.08.2010 06:25:25 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Closed Connection 0x80074e20 FWX_E_GRACEFUL_SHUTDOWN Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:25 2276 0 0 0 0x0 0x0 - 24.08.2010 06:25:25 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Initiated Connection 0x0 ERROR_SUCCESS Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:26 2276 0 0 0 0x0 0x0 - 24.08.2010 06:25:26 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Closed Connection 0x80074e20 FWX_E_GRACEFUL_SHUTDOWN Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:26 2277 0 0 0 0x0 0x0 - 24.08.2010 06:25:26 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Initiated Connection 0x0 ERROR_SUCCESS Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.159 - UDP - - - 24.08.2010 13:25:26 68 0 0 0 0x0 0x0 - 24.08.2010 06:25:26 10.XXX.YY.159 255.255.255.255 67 DHCP (request) Denied Connection [Enterprise] Default rule 0xc004000d FWX_E_POLICY_RULES_DENIED Internal Local Host - PROXYTEST Firewall 10.XXX.YY.166 - UDP - - - 24.08.2010 13:25:26 68 0 0 0 0x0 0x0 - 24.08.2010 06:25:26 10.XXX.YY.166 255.255.255.255 67 DHCP (request) Denied Connection [Enterprise] Default rule 0xc004000d FWX_E_POLICY_RULES_DENIED Internal Local Host - PROXYTEST Firewall 0.0.0.0 Mozilla/4.0 (compatible; MSIE 8.0; Windows NT 5.1; Trident/4.0; .NET CLR 2.0.50727; .NET CLR 3.0.4506.2152; .NET CLR 3.5.30729) Yes Proxy 10.XXX.YY.175 TCP GET Internet - - - Req ID: 096c76ae; Compression: client=No, server=No, compress rate=0% decompress rate=0% - - - 24.08.2010 13:25:27 0 2945 2581 446 0x0 0x40 24.08.2010 06:25:27 10.XXX.YY.174 10.XXX.YY.175 80 http Failed Connection Attempt MyHTTPAccess 10061 anonymous Internal Local Host http://www.vg.no/ PROXYTEST Web Proxy Filter 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:27 2277 0 0 0 0x0 0x0 - 24.08.2010 06:25:27 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Closed Connection 0x80074e20 FWX_E_GRACEFUL_SHUTDOWN Local Host Local Host - PROXYTEST Firewall

    Read the article

  • Asus P8P67 Rev. 3.1 Motherboard issues powering on and saving settings

    - by Scott
    Edit: New Information Have some updated information from the old question below: So basically my issue right now is somewhat similar, but I've been able to rule out a couple of things. I don't think this has anything to do with light on the motherboard. No matter what lights are on/off on the motherboard when the computer is off, they don't affect this issue. The main power LED on the Mobo is always lit when the power supply is turned on, and that's what matters anyway. Even when the main power LED is on, the PC will NOT boot up the first time I hit the power switch. I have to go reset the power supply (make all lights turn off on the Mobo and back on), and THEN hit the power switch. Then everything boots up. Also, the BIOS settings are reset every time this happens. Asus Tech Support told me to try jumping the power with something metal to try and rule out that it's a problem with the connectors getting power, or if it's a problem with the case power switch pins - haven't done that yet though. Any ideas? This is a lot simpler than it was before when I thought it had to do with certain LED indicators for RAM, EPU, etc. Original Question So I built my new desktop just about 3 weeks ago. I've been having a few issues which I think are all related to my motherboard, an Asus P8P67 Revision 3.1, but I'm not 100% sure as this is really the first from-scratch build I've ever done. I've posted these questions on the Asus forums, Asus Tech Support, and the Corsair forums as well as I thought it might have something to do with my power supply at one point. None of these avenues have solved my issue until now completely, so I thought I'd come here to see what you guys think. Here's what's happening: My computer is off, and I go to power it on. I press the power switch on the case (Antec Nine Hundred), and nothing seems to happen. Upon further inspection, I see that what this actually does is simply turn on the EPU LED on my motherboard, but doesn't actually boot anything up. I then have to go and flip the main power switch on the power supply off and back on. What this does is turn off all lights on the Motherboard after a few seconds, and turn them all back on (including the EPU LED that was off before I hit the power switch the first time). Now, hitting the power switch works. The machine boots up fine, and starts going through the boot up process. As a side note: My Motherboard is set to "Force BIOS", and every single time I change this to do the opposite, the next time my computer boots up that change reverts itself. I think this may be due to the fact that I am doing the hard reset on the power supply each time, but I'm not sure. I had thought that the Motherboard would keep its BIOS settings unless you did something to the Mobo itself - so this may be a related issue, or something else completely. That's basically it. Once it's on, it's on. It works fine, recognizes all of my hardware, and runs great. All fans/lights in the case work great, and I'm getting standard readings. The next time I go to shut the computer down however, I can expect the same exact process getting it up and running, including being forced to go into BIOS and exit again before I can load Windows. Another side note: If I power on my computer using the power switch DIRECTLY after shutting it down, it powers right back on (I think this is because the EPU LED light doesn't have time to turn off). It looks as if as long as the EPU LED is lit up on the motherboard before I hit the power switch on the case, the thing will boot up fine (although this doesn't explain the "Force BIOS" issue, at least it's something). Any ideas? Thanks guys. P.S. - System Specs Asus P8P67 Rev. 3.1 Motherboard Intel Core i7 2600K Processor 16GB (4x4GB) G-Skill 1600 RAM NVIDIA EVGA GTX 570 Video Card Crucial 128GB SSD HD Corsair 850W Power Supply Seagate 2TB HDD

    Read the article

  • File copying utility like rsync with error handling like ddrescue, for data recovery from a hard drive with bad sectors or hardware failure

    - by purefusion
    I have a hard drive with either bad blocks or sectors that are failing to read due to potential mechanical issues, such as a bad disk head, bad motor, or some other issue that is causing the hard drive to read data excruciatingly slowly and with lots of read errors. I'm seeing an average of 50 KB/sec, with some reads dropping below 10 KB/sec, and frequently it gets stuck on a file or sector altogether, usually for quite a long time—from 2-10 minutes or more (when using rsync, before it times out). Speed seems to vary wildly, and it gets stuck on files a lot, and when it finally gets "unstuck" it only seems to last for a short burst before it gets stuck again. The drive is also very quiet with only an occasional sound of files copying (usually when it gets stuck/unstuck for a brief time, before getting stuck again). Thus, there are none of those evil sounds that are normally associated with HDD death. Someone suggested that the problems sounded like they might be caused by a misaligned disk head, which requires a lot of re-reads before it finally reads data with success. Sounds plausible, but I digress... Anyway, the problem with rsync is that it seems to have no decent error handling support. Obviously, it wasn't meant for use in recovering data from failing hard drives, but all the so-called "data recovery" utilities out there that are meant for such use usually focus on recovery of deleted files or messed up partitions, rather than copying files off dying hard drives. Deleted file recovery is not what I need, obviously, so perhaps you can understand my disappointment in not being able to find what I'm after yet. Naturally, this is where you'd probably say "You should use ddrescue!" Well, that's all fine and dandy, but I've already got most of the data backed up, so I just want to recover certain files. I'm not concerned with trying to recover a full partition block-by-block as ddrescue does. I am only interested in rescuing just specific files and directories. Ideally, what I'd like is some sort of cross between rsync and ddrescue: something that lets me specify source and destination as directories of normal files like rsync (rather than two full partitions as ddrescue requires), with a way to skip files with errors in an initial run, and then allows me to attempt recovery of those files with errors in a later run (with a slightly altered command, of course), perhaps even offering an option to specify the number of retry attempts ...just like how ddrescue works with blocks, only I want a utility that works with specific files/directories like rsync does. So am I daydreaming here, or does something out there exist that can do this? Or, maybe even a way to make rsync or ddrescue work in such a way? I'm really open to whatever solutions might work, so long as they let me choose which files I want to "rescue", and can skip files with errors in the initial run, and try/retry those errors again later. So far I've tried rsync with the following options, but it often gets stuck on a file for longer than the timeout, and ideally I'd just like it to move on to the next file and come back later to the files it gets stuck on. I don't think that's possible though. Anyway, here's what I've been using up till now: rsync -avP --stats --block-size=512 --timeout=600 /path/to/source/* /path/to/destination/

    Read the article

  • Determining the required depth and specifications for a server cabinet

    - by Bingu Bingme
    I'm trying to understand the considerations ("why") that go into determining the specifications ("what") for a rackmount server cabinet, in order to determine what sort of rack I should purchase for my home use. Since this is for home use, I won't be following certain best practices (eg. hot/cold aisle, not even air conditioning) and may be willing to sacrifice in various areas in order to reduce cost and footprint - but please advise if there are safety concerns or other considerations to note. The most basic specs for a server cabinet are the dimensions (external width x external depth x usable height). Width: commonly 600mm or 800mm (if the use case requires extra clearance around the sides, such as if there is lots of cabling). In my case and most common cases, I'm going to stick with 600mm. Height: Select a sufficiently tall rack to fit my equipment. But how much may I stuff into it? Eg, if there is a 15U rack, can I really populate it with 15U of servers, or should I leave 1U at top and bottom for air circulation? Depth: Racks commonly have external depth of 600mm (network equipment), 800mm, 1000mm, or even longer. I'm trying to see how to fit into the 800mm depth. With reference to http://www.server-racks.com/rack-mount-depth.html, I'm hoping to have the front and rear posts mounted ~ 28.5" (72cm) apart, which would leave only 8cm for front space and rear space. How much rear space (from rear posts to back of rack) do I really need? I won't use cable management arms, so can I mount a 72cm depth server since the power, KVM, network cables won't take up much depth? My most important equipment are all < 60cm depth (4U chassis) and should comfortably fit within the 800mm cabinet. The rest of the equipment are very old 1U servers that range from 65-72cm depth. I might still want to make further use of them, or I might discard them since they are so old. Even if the 72cm servers cannot be powered on in an 800mm rack, I should be able to use them as 1U shelves. But, what server depth can I expect to be able to operate? Or am I forced to upgrade to 1000mm depth racks in order to use any servers deeper than 60cm? With reference to best practices for HP racks, some other specs and installation considerations: There aren't any minimum recommendations for clearance on the sides of the rack. It is recommended to leave 48" front clearance. The 48" front clearance is based on 32" chassis depth, 13" to extend the rack rails and mate the inner/outer rails, and 3" for movement. If I don't use such rails (eg, use shelves instead), it should be sufficient to leave front clearance of chassis depth + 3". It is recommended to leave 30" rear clearance "to provide space for servicing the rack". I'm planning to back the rack into a corner of the room, and wheel it slightly out when I need to access the rear. If the wheeling plan is ok, I still need to know how much rear clearance is required for air circulation and ventilation purposes. Castor wheels and stabilising feet. Since I'm backing the rack into a corner of the room, I'll only be able to set the stabilising feet on the front corners. Thoughts on safety? The rack that I'm considering has front glass doors with side ventilation slits and fully perforated rear doors. I'm hoping this will be a good balance between temperature and noise (only ventilation slits facing out the front, while the rear is facing the walls). Or is the sound of high-rpm fans going to escape through the front slits anyway and destroy my sanity?

    Read the article

  • Setup access to SAS RAID drives with NTFS partitions on CentOS Machine

    - by Quanano
    We have a Dell Poweredge 2900 system with Adaptec 39320A SCSI CONTROLLER CARD and 4 SAS hard drives attached, with NTFS partitions on them. We installed CentOS on the other raid array with a different controller and it is working fine. We are now trying to access the drives shown above and they are not being shown in /dev as sdb, etc. sda is the drive that we installed centos on and it has sda1, sda2, sda3, etc. The CDROM has been picked up as well. If I scan for scsi devices then the perc and adaptec controllers are both found. sg0 is the CDROM and sg2 is the centos installed, however I think sg1 is the other drive but I cannot see anyway to mount the partitions, as only the drive is listed in /dev. Thanks. EXTRA INFO fdisk -l Disk /dev/sda: 72.7 GB, 72746008576 bytes 255 heads, 63 sectors/track, 8844 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x11e3119f Device Boot Start End Blocks Id System /dev/sda1 * 1 64 512000 83 Linux Partition 1 does not end on cylinder boundary. /dev/sda2 64 8845 70528000 8e Linux LVM Disk /dev/mapper/vg_lal2server-lv_root: 34.4 GB, 34431041536 bytes 255 heads, 63 sectors/track, 4186 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_root doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_swap: 21.1 GB, 21139292160 bytes 255 heads, 63 sectors/track, 2570 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_swap doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_home: 16.6 GB, 16647192576 bytes 255 heads, 63 sectors/track, 2023 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_home doesn't contain a valid partition table These are all from the install hdd not the additional hard drives modprobe a320raid FATAL: Module a320raid not found. lsscsi -v [0:0:0:0] cd/dvd TSSTcorp CDRWDVD TS-H492C DE02 /dev/sr0 dir: /sys/bus/scsi/devices/0:0:0:0 [/sys/devices/pci0000:00/0000:00:1f.1/host0/target0:0:0/0:0:0:0] [4:0:10:0] enclosu DP BACKPLANE 1.05 - dir: /sys/bus/scsi/devices/4:0:10:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:0:10/4:0:10:0] [4:2:0:0] disk DELL PERC 5/i 1.03 /dev/sda dir: /sys/bus/scsi/devices/4:2:0:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:2:0/4:2:0:0] . lsmod Module Size Used by fuse 66285 0 des_generic 16604 0 ecb 2209 0 md4 3461 0 nls_utf8 1455 0 cifs 278370 0 autofs4 26888 4 ipt_REJECT 2383 0 ip6t_REJECT 4628 2 nf_conntrack_ipv6 8748 2 nf_defrag_ipv6 12182 1 nf_conntrack_ipv6 xt_state 1492 2 nf_conntrack 79453 2 nf_conntrack_ipv6,xt_state ip6table_filter 2889 1 ip6_tables 19458 1 ip6table_filter ipv6 322029 31 ip6t_REJECT,nf_conntrack_ipv6,nf_defrag_ipv6 bnx2 79618 0 ses 6859 0 enclosure 8395 1 ses dcdbas 9219 0 serio_raw 4818 0 sg 30124 0 iTCO_wdt 13662 0 iTCO_vendor_support 3088 1 iTCO_wdt i5000_edac 8867 0 edac_core 46773 3 i5000_edac i5k_amb 5105 0 shpchp 33482 0 ext4 364410 3 mbcache 8144 1 ext4 jbd2 88738 1 ext4 sd_mod 39488 3 crc_t10dif 1541 1 sd_mod sr_mod 16228 0 cdrom 39771 1 sr_mod megaraid_sas 77090 2 aic79xx 129492 0 scsi_transport_spi 26151 1 aic79xx pata_acpi 3701 0 ata_generic 3837 0 ata_piix 22846 0 radeon 1023359 1 ttm 70328 1 radeon drm_kms_helper 33236 1 radeon drm 230675 3 radeon,ttm,drm_kms_helper i2c_algo_bit 5762 1 radeon i2c_core 31276 4 radeon,drm_kms_helper,drm,i2c_algo_bit dm_mirror 14101 0 dm_region_hash 12170 1 dm_mirror dm_log 10122 2 dm_mirror,dm_region_hash dm_mod 81500 11 dm_mirror,dm_log

    Read the article

  • Dell Latitude E6430 Docking Station + Dual Monitor + Laptop Screen Tri-Monitor setup

    - by Larry
    I have a company issued laptop and docking station as well as two monitors The specifications of the hardware are as follows; Laptop: Latitude E6430 BIOS: A02.00 Processor: i7-3720QM CPU @ 2.60 (8 CPUs) Memory: 4096MB RAM Page file: 1825MB used, 4793MB available DirectX 11 Display Driver/Chip: MVIDIA NVS 5200M DAC: Integrated RAMDAC Aprox Total Memory: 2376 (Above 3 details same for both displays) Current Display Mode (Display 1): 1600x900 Current Display Mode (Display 2): 1440x900 the docking station is a Dell Latitude E6420 Docking Station PR03X Port Replicator and I don't think the monitor model is particularly relevant to resolving this issue but they are both Acer V193Ws The story goes like this; the laptop works fine if I VGA one monitor into the laptop through the vga port on the back of the lefthand side of the laptop I can achieve dual monitor display fine (laptop screen + monitor) if I plug the laptop into the docking station and use the vga port in the back of the docking station I can dual monitor fine (laptop screen + monitor) if I plug the laptop into the docking station, the laptop's lefthand side VGA port no longer seems to function at all I've spoken to internal IT about this issue and they're going to get me some kind of VGA splitter or a DVI-VGA adapter to use with the docking station for the second Acer Monitor, but that isn't going to happen for a few days. So I guess what I'm wondering is; is there any way to continue to use the side VGA port on my laptop while using the docking station VGA port? and as a secondary 'followup' pending resolution of the initial issue with getting both monitors up and running (at the moment I have both monitors on my desk but am just using my laptop screen as one of my dual monitor display with one of the monitors [the one connected to dock]), is there any way to CONTINUE to use my laptop monitor to in effect have a triple monitor display (2 monitors + docked laptop)? I am wondering this because internal IT told me that they were aware of some issues with the particular display drivers in my box and triple monitor displays but weren't really going to look TOO much in-depth into that (which is perfectly understandable) since getting the adapter for the dual monitors up and running was the greater priority within their purview. So this is a two parter; Can I dual monitor using two vga cables with 1 docking station vga port and one laptop vga port? is there a setting that can be tweaked somewhere? because plugging the box into the station seems to make the side port stop working and... Is there any reasonably simple and cost-effective work around (e.g. I am find with shelling out maybe a few dollars out of my own pocket for some hardware or software to make my company box tri-display capable) but if this requires some extensive rebuild or new OSs or doing stuff to the BIOS I'd rather have a straight answer about this being untenable as a slight modification to a (once again) company laptop and stop wasting time looking into it Thanks! and please let me know if you guys need any more details (tech specs or something) to answer this question [EDIT] 2/10/2014 Just an update; turned out it really was just a hardware limitation issue. The old laptop just couldn't hack it. Got a new laptop with a better video card and different monitors from my company and am successfully using a triple display currently (2 monitors + laptop screen)

    Read the article

  • Postfix not sending/allowing receiving of messages after server (hardware) changed

    - by 537mfb
    We had na old notebook runing Ubuntu 12.04 working as a web/ftp/mail server and it worked but since the notebook was a notebook and pretty old and unreliable, a desktop was bought to replace it before it stopped working all together. Due to issues with the new desktop's vídeo card, we couldn't use Ubuntu 12.04 so we installed Ubuntu 13.10 and wen't about configuring it. Since we removed the notebook from the network, we kept the same Computer Name and local IP address to make things as close to the old server as possible configuration-wise. However, something has gone wrong since Postfix is throwing error 451 4.3.0 lookup faillure on every attempt to send a mail, and no email can be received either. Our main.cf file is a copy of the one we were using (and working) on the old server (notice we use EHCP) # See /usr/share/postfix/main.cf.dist for a commented, more complete version # Debian specific: Specifying a file name will cause the first # line of that file to be used as the name. The Debian default # is /etc/mailname. #myorigin = /etc/mailname smtpd_banner = $myhostname ESMTP $mail_name powered by Easy Hosting Control Panel (ehcp) on Ubuntu, www.ehcp.net biff = no # appending .domain is the MUA's job. append_dot_mydomain = no # Uncomment the next line to generate "delayed mail" warnings #delay_warning_time = 4h readme_directory = no myhostname = m21-traducoes.com.pt relayhost = mydestination = localhost, 89.152.248.139 mynetworks = 127.0.0.0/8, 192.168.0.0/16, 172.16.0.0/16, 10.0.0.0/8, 89.152.248.0/24 virtual_alias_domains = virtual_alias_maps = proxy:mysql:/etc/postfix/mysql-virtual_forwardings.cf, proxy:mysql:/etc/postfix/mysql-virtual_email2email.cf transport_maps = proxy:mysql:/etc/postfix/mysql-virtual_transports.cf virtual_mailbox_domains = proxy:mysql:/etc/postfix/mysql-virtual_domains.cf virtual_mailbox_maps = proxy:mysql:/etc/postfix/mysql-virtual_mailboxes.cf virtual_mailbox_base = /home/vmail virtual_uid_maps = static:5000 virtual_gid_maps = static:5000 smtpd_sasl_auth_enable = yes smtpd_sasl_security_options = noanonymous broken_sasl_auth_clients = yes smtpd_recipient_restrictions = permit_mynetworks,permit_sasl_authenticated,check_client_access hash:/var/lib/pop-before-smtp/hosts,reject_unauth_destination smtp_use_tls = yes smtpd_use_tls = yes smtpd_tls_auth_only = no smtpd_tls_CAfile = /etc/postfix/cacert.pem smtpd_tls_cert_file = /etc/postfix/smtpd.cert smtpd_tls_key_file = /etc/postfix/smtpd.key smtpd_tls_loglevel = 1 smtpd_tls_received_header = yes smtpd_tls_session_cache_timeout = 3600s tls_random_source = dev:/dev/urandom virtual_create_maildirsize = yes virtual_mailbox_extended = yes virtual_mailbox_limit_maps = proxy:mysql:/etc/postfix/mysql-virtual_mailbox_limit_maps.cf virtual_mailbox_limit_override = yes virtual_maildir_limit_message = "The user you are trying to reach is over quota." virtual_overquota_bounce = yes debug_peer_list = sender_canonical_maps = debug_peer_level = 1 proxy_read_maps = $local_recipient_maps $mydestination $virtual_alias_maps $virtual_alias_domains $virtual_mailbox_maps $virtual_mailbox_domains $relay_recipient_maps $canonical_maps $sender_canonical_maps $recipient_canonical_maps $relocated_maps $mynetworks $virtual_mailbox_limit_maps $transport_maps alias_maps = hash:/etc/aliases smtpd_relay_restrictions = permit_mynetworks, permit_sasl_authenticated,check_client_access hash:/var/lib/pop-before-smtp/hosts,reject_unauth_destination smtpd_destination_concurrency_limit = 2 smtpd_destination_rate_delay = 1s smtpd_extra_recipient_limit = 10 disable_vrfy_command = yes smtpd_delay_reject = yes smtpd_helo_required = yes smtpd_error_sleep_time = 1s smtpd_soft_error_limit = 10 smtpd_hard_error_limit = 20 This configuration was working before but now everytime i try to send a mail in squirrelmail it reports: Message not sent. Server replied: Requested action aborted: error in processing 451 4.3.0 <[email protected]>: Temporary lookup failure And i can't send mail to it from outsider either. Any ideas? EDIT: Here are some issues MXToolBox reports to my domain, answering hopefully to @Teun Vink: BlackList Mail Server Web Server DNS Error 4 0 2 0 Warnings 0 0 0 3 Passed 0 6 3 12 So the domain is on some blacklist, but that doesn't explain the error at all No mail server issues found (except it's not working) Those two web server errors it's because i don't have HTTPS workin (No SSL Certificate) so the test fails Those 3 DNS warnings we're already there when it was working with the other machine and are related to stuff i can't control: SOA Refresh Value is outside of the recommended range SOA Expire Value out of recommended range SOA NXDOMAIN Value too high I've searched and as far as i can tell only the guys who sold the retail can change those values and they won't. Edit2: I half solved the issue.on the new machine postfix was installed but postfix-mysql waasn't so he couldn't connect to the database (rookie mistake). After fixing that, i can now send mails to the outsider without any issues, however i am still not able to receive mails from utside. The sender doesn't get any message warning about the non-delivery but the message doesn't fall in the inbox and the log shows: Nov 13 15:11:57 m21-traducoes postfix/smtpd[5872]: NOQUEUE: reject: RCPT from re lay4.ptmail.sapo.pt[212.55.154.24]: 451 4.3.5 <relay4.ptmail.sapo.pt[212.55.154. 24]>: Client host rejected: Server configuration error; from=<[email protected]> to=<[email protected]> proto=SMTP helo=<sapo.pt> Nov 13 15:11:57 m21-traducoes postfix/smtpd[5872]: disconnect from relay4.ptmail .sapo.pt[212.55.154.24]

    Read the article

  • can't connect 2 subnets through RRAS 2008 r2

    - by mcdwight6
    I'm working on a project for a networking class. In VMWare Workstation, I have to set up a 2008 r2 server with DHCP reservations for 2 clients on separate subnets and have them ping each other. Here is the output of the route print command: =========================================================================== Interface List 13 ...00 50 56 2a e7 11 ...... Intel(R) PRO/1000 MT Network Connection #3 10 ...00 0c 29 66 88 dd ...... Intel(R) PRO/1000 MT Network Connection 1 ........................... Software Loopback Interface 1 24 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter 11 ...02 00 54 55 4e 01 ...... Teredo Tunneling Pseudo-Interface 14 ...00 00 00 00 00 00 00 e0 6TO4 Adapter 16 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #2 17 ...00 00 00 00 00 00 00 e0 isatap.{5B8FB196-616F-4168-A020-03E63A309CEC} =========================================================================== IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 On-link 10.0.0.2 266 0.0.0.0 0.0.0.0 On-link 223.6.6.2 266 10.0.0.0 255.0.0.0 On-link 10.0.0.2 266 10.0.0.2 255.255.255.255 On-link 10.0.0.2 266 10.255.255.255 255.255.255.255 On-link 10.0.0.2 266 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 128.6.0.0 255.255.0.0 On-link 10.0.0.2 11 128.6.255.255 255.255.255.255 On-link 10.0.0.2 266 223.6.6.0 255.255.255.0 On-link 10.0.0.2 11 223.6.6.0 255.255.255.0 On-link 223.6.6.2 266 223.6.6.2 255.255.255.255 On-link 223.6.6.2 266 223.6.6.255 255.255.255.255 On-link 10.0.0.2 266 223.6.6.255 255.255.255.255 On-link 223.6.6.2 266 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 10.0.0.2 266 224.0.0.0 240.0.0.0 On-link 223.6.6.2 266 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 10.0.0.2 266 255.255.255.255 255.255.255.255 On-link 223.6.6.2 266 =========================================================================== Persistent Routes: Network Address Netmask Gateway Address Metric 0.0.0.0 0.0.0.0 10.0.0.2 Default 0.0.0.0 0.0.0.0 128.6.0.2 Default 0.0.0.0 0.0.0.0 223.6.6.2 Default 128.6.0.0 255.255.0.0 10.0.0.2 1 223.6.6.0 255.255.255.0 10.0.0.2 1 =========================================================================== IPv6 Route Table =========================================================================== Active Routes: If Metric Network Destination Gateway 1 306 ::1/128 On-link 14 1010 2002::/16 On-link 14 266 2002:8006:2::8006:2/128 On-link 1 306 ff00::/8 On-link =========================================================================== Persistent Routes: None My problem is that although I have set up both dynamic and persistent static routes in my r2 server, neither of the clients can ping even the NIC outside its own subnet. For example Client A can ping the NIC at 10.0.0.2 and vice-versa, but it gets a general transmit failure when it tries to ping the card at 223.6.6.2, let alone trying to ping the other client. I have completely disabled the firewalls on all machines and anything else I could think of, without success. What am I missing? Edit: Since posting this, I also noticed that the default gateways on my 2 NICs keep getting zeroed out. Does anyone know a fix for this?

    Read the article

  • Gaming blew fuse and causes funny smell: how to overcome?

    - by George Tomlinson
    I've been gaming for a while now. When playing certain games this PC goes into overdrive. The fan/fans start/s to sound like a jet engine it/they get/s so busy. Also I have smelt burning when this has happened. The fuse blew on the 4 socket adapter I was using recently. On the following thread someone said this could be due to the PSU not being strong enough to handle the load, in what it seems could be a related issue someone had, although the person who posted this question did say that blowing a fan on their PC stopped it crashing in that case: http://www.tomshardware.co.uk/answers/id-2047543/gtx-650-overheating-issue.html. This is exactly what they said: Your GPU isn't overheating. 70+ before it would shutdown and cause a restart. Make sure your PSU is strong enough to handle your new system at load and possibly run Memtest to check your RAM (although not BSOD'ing and just shutting down points to the PSU). This (the PSU part) makes more sense to me than it being to do with dust etc, since it seems a more plausible explanation of why the fuse blew. The PC has no problems except when playing certain games: i.e. TERA Rising and WoW with add-ons (I think WoW is ok as long as I don't have more than 1 add-on (Healers Have To Die)). I'm just wondering if anyone knows or can suggest what I might be able to do to be able to play these games without this problem occurring. The PC's spec is this: Display: NVIDIA GeForce GTX 650 8GB RAM (6 available) Processor: AMD FX (tm) - 8120 Eight-Core Processor - 3.1 GHz, 4 Cores, 8 Logical Processors I have read on another post that forcing vsync in the Nvidia Control Panel helped with what seems could be a similar problem, so I plan to see if that solves it, God permitting. EDIT: I tried the Vsync thing, and it seems the situation may have improved, although this may be due to something else: i.e. maybe the PC was working harder yesterday, due to just having downloaded a few things or lots of things running. I'm still noticing the funny smell when playing TERA. It's not so much burning: it's more like glue. The smell might have had a burning element to it in the past, but I think it's always had a glue element. EDIT 2: the PSU is an 'ATX Switching Power Supply', Model E-500ATX. Other info it gives on the PSU is 230V, Current 10A and Frequency 50-60Hz. It also has some other info which I can supply if necessary. Putting the PC plug in the wall socket instead of the power strip seems like it might have reduced the load on the PC quite a bit: I think it sounds less stressed. it has been off for a while whilst I took the side panel off though, so I'll wait to see what happens before getting too excited. EDIT 3: hmm. So here's the latest: just playing TERA. The fan's running quite fast again. Hard to tell whether switching to the wall socket has made a difference in terms of strain on the PC: I don't know if one would expect it to. Still seems like it might have helped though. Oh and there didn't seem to be much dust in the PC, although I didn't disconnect any components. I'm still getting the glue type smell. ASIDE: reminds me of someone on a PC near me at the library once who was actually sniffing glue right there in front of everyone while on the PC and he started talking about how he was sniffing glue. lol. That's no joke. EDIT 4: So the questions now are: Question 1: Is the smell something I should sort out? (If so, how might I do this?) Question 2: is it necessary to take any steps to prevent blowing another fuse (and if so which step/s?).

    Read the article

  • Hard drive after PCB swap strange stuff

    - by ramyy
    I’ve done a PCB swap to my HDD. The HDD model is: WD6400AAKS-00A7B2. The original PCB PN matches the new one (first three letter groups), though the cache mismatches (16MB original, 8MB new). The Hardware store that made the swap told me it was hard to do the swap, they have done firmware adaptation. I can see that this firmware version does not match the original, (01.03B01 original, 05.04E05 new). Still I can see that the serial number and model of the drive is correct, the hard drive appeared normal in the BIOS, all the partitions show and everything appears normal. I have encountered three things though, I have left the drive non operated for 2-3 weeks after the swap to avoid corrupting the data or anything else the new PCB might cause, until I buy a new drive and backup the data. I got a drive, and when I powered the old drive manually (I have a laptop, I use a normal desktop power supply and a USB/SATA connector), I heard the motor start and I could hear ticking as if the motor’s somehow struggling to start, and then the motor sound starts again then the ticking, and so on.. I tried powering again it happened again. The third time it started normally and I could see everything normally. I took the chance and copied all the data over to the new drive. When I was done, I powered off the drive (after more than 25 hours of continuous operation), tried to power it up again and it did so normally, and so are the times I powered it up later; but I got very suspicious now. What could be the problem here? And what happened new, it used to power normally after the swap directly? The second thing that happened is that I found size differences with some files; some include movies, songs, (.iso) files for games, and programs. I could find the size is the same, but size on disk is a little more on the new drive for these files. . I’ve tried some of those files (with size differences) they worked fine. They are not too much but still make you suspicious of the integrity of the data copied; one cannot try if all files are working for about (580 GB) worth of data. I tried copying these files on the same partition they exist of the old drive; they are the same in size as when copied to the new drive (allocation unit size not the issue). I took an image of a partition (sector by sector including empty ones) and when I explore it, these file sizes are equal to the original (old drive); I copy them anywhere else their size on disk, increases, i.e becomes equal to the ones I copy from the old drive itself anywhere. Why the size difference and can one trust the integrity of the data?? The third thing is that when I connect my new external USB HDD, the partitions of the old HDD unmount and then mount again. Connected are: (USB mouse + Old HDD) then external HDD. Why that happens?? Considering the following: I compared the SMART reports from after the swap directly and after the copying, no error readings or reallocated sectors where reported. Here they are: http://www.image-share.com/ijpg-1939-219.html I later ran both WD data life guard tests and they came out passed. I’m worried for this drive since I must be sure the data is fine and safe on the new one, and I will consider it backup for the new one, since you can’t trust anything anymore. I hope you can forgive me for the length of the post, but couldn’t ignore any of the details, this hard drive contains very important data to me and I have to deal with the situation with great care.

    Read the article

  • USB connection is unstable with Nexus S 2.3.4 on AMD 64 running 64-bit Windows 7, but works with 32-bit Windows Vista

    - by Mike
    The USB connection is unstable with Nexus S (Android 2.3.4) on AMD 64 running 64-bit Windows 7, but it works with 32-bit Windows Vista. Problem Description: On the 64-bit Windows 7 machine my Nexus S appears to connect, but then it disconnects moments later. Neither accessing USB storage or loading an Android application package file (APK) using the Android Debug Bridge (ADB) work. On 32-bit Windows Vista using the same USB cable, USB storage works. I haven't tried the ADB on 32-bit Windows Vista. Reproduction steps for USB storage: (I have provided the reproduction steps for USB storage and not ADB, because if one isn't working, then the other isn't working either and the USB storage reproduction steps are shorter to document.) Connect the USB cable to the Nexus S and my Windows 7 machine. Effect: The "USB Mass Storage, USB Connected" dialog appears with the button "Turn on USB storage." Click "Turn on USB Storage" Effect: The "working circle" appears. A dialog briefly appears saying "USB storage in use," then it either returns me to Step 1 (now that I am running 2.3.4) or is replaced with the Nexus S's application homepage (while I was running 2.3.3). I'm not sure if the version matters, but I mention it for completeness. On the 32-bit Windows Vista machine the connection is stable. I am able to navigate through the Nexus S file system create, read, update, and delete files, etc. I haven't tried connecting with the ADB. Troubleshooting summary: Tried and failed: Uninstalling and reinstalling the Android USB drivers including removing the files. Uninstalling my custom software Pulling the Nexus S's battery Restarting the Nexus S Restarting 64-bit Windows 7 Changing USB ports on the 64-bit Windows 7 box Compared the dates and file size on the DLLs in my google-usb_driver\amd64 directory and the windows\System32 directory. They match. The sizes for the google-usb_driver\i386 directory do not match (expected). Turning off Debugging mode on the Nexus S does not resolve the problem. Searching Google. Tried and succeeded: Connecting to another machine (Windows Vista) using the same USB cable and Nexus S phone. Troubleshooting observations: I notice that uninstalling the device drivers and deleting the files, then reinstalling the drivers, then rebooting 64-bit Windows 7 then unplugging the Nexus S, then plugging it back in occasionally helps for a short amount of time (minutes to hours, not days). When it is working, I can both access the Nexus S's drive and load/test applications using the ADB. I have observed some wonky behavior in the Device Manager that I haven't tracked down. Sometimes the black Nexus S image appears in the list of devices. Sometimes the image displays as a computer with a green ISA card. Sometimes it neither appears on the top level of devices nor under “other devices,” but it does appear under "disk drives" as "Android UMS Composite USB Device." System configuration: The Nexus S is running Android OS 2.3.4's "Settings\about phone\System updates" indicates that it is up to date as of May 21st 2011. Both 32-bit Windows Vista and 64-bit Windows 7 are up to date. The Windows Vista system is running on an Intel 32-bit processor. Windows 7 is running on an AMD 64-bit processor. I have done Android development on both systems, but I usually develop on the 64-bit Windows 7 machine.

    Read the article

  • Android GPS timeout

    - by Scott Saunders
    I'm writing an Android application that, among other things, needs to send the current GPS coordinates to a server when the user tells it to. From a context menu, I run the service below. The service is a LocationListener and requests updates from the LocationManager. When it gets a location (onLocationChanged()), it removes itself as a listener and sends the coordinates off to the server. All of this is working. However, if GPS coordinates are not quickly available, my service just keeps running until it gets some. It holds up the UI with a progress dialog, which is annoying. Worse, if the user has moved since starting the service, the first GPS coordinates might be wrong and the app will send bad data to the server. I need a timeout on the service. Is there a good way to do that? I'm not very experienced with threads. I think I can run a Runnable in the onStartCommand() method that will somehow count down 30 seconds and then, if there is no GPS result yet, call my service's stop() method. Does that sound like the best way to do this? Alternatively, is it possible to tell if the GPS cannot get a fix? How would I go about doing that? Edit: To further clarify, I'm looking for the best way to "give up" on getting a Location after some amount of time. public class AddCurrentLocation extends Service implements LocationListener { Application app; LocationManager mLocManager; ProgressDialog mDialog; @Override public int onStartCommand(Intent intent, int arg0, int arg1) { app = getApplication(); // show progress dialog if (app.getScreen() != null) { mDialog = ProgressDialog.show(app.getScreen(), "", "Adding Location. Please wait...", true); } // find GPS service and start listening Criteria criteria = new Criteria(); criteria.setAccuracy(Criteria.ACCURACY_FINE); mLocManager = (LocationManager) getSystemService(Context.LOCATION_SERVICE); String bestProvider = mLocManager.getBestProvider(criteria, true); mLocManager.requestLocationUpdates(bestProvider, 2000, 0, this); return START_NOT_STICKY; } private void stop() { mLocManager.removeUpdates(this); if (mDialog != null) { mDialog.dismiss(); } stopSelf(); } @Override public void onLocationChanged(Location location) { // done with GPS stop listening mLocManager.removeUpdates(this); sendLocation(location); // method to send info to server stop(); } // other required methods and sendLocation() ... }

    Read the article

  • UIScrollView image/photo viewer with paging enabled and zooming

    - by Mike Weller
    OK, I think it's time to make an official place on the internet for this problem: How to make a UIScrollView photoviewer with paging and zooming. Welcome my fellow UIScrollView hackers. I have a UIScrollView with paging enabled, and I'm displaying UIImageViews like the built-in photos app. (Does this sound familiar yet?) I found the following project on github: http://wiki.github.com/andreyvit/ScrollingMadness Which shows how to implement zooming in a scroll view while paging is enabled. If anyone else tries this out, I actually had to remove the UIScrollView subclass and use the native class otherwise it doesn't work. I think it's because of changes in the 3.0 SDK relating to how the scroll view intercepts touch events. So the the idea is to remove all the other views when you start zooming, and move the current view to (0, 0) in the scrollview, updating the contentsize etc. Then when you zoom back to 1.0f it adds the other views back and puts things all back in order. Anyway, that project works perfectly in the simulator, but on the device there is some nasty movement of the view you are resizing, which looks like it's caused by the fact we are changing the contentsize/offset etc. for the view being resized. You have to do this view moving otherwise you can pan left through the whitespace left by the other views. I found one interesting note in the "Known Issues" of the 3.0 SDK release notes: UIScrollView: After zooming, content inset is ignored and content is left in the wrong position. This kind of sounds like what is happening here. After zooming in, the view will shift offscreen because you have changed the offset etc. I've spent hours on this already and I'm slowing coming to the sad realization that this just isn't going to work. Three20's photo viewer is out of the question: it's too heavy weight and there is too much unnecessary UI and other behaviour. The built in Photo app seems to do some magic. If you zoom in on an image and pan to the far edges, the current photo moves independently of the photo next to it which isn't what you get when trying this with a standard UIScrollView. I've seen discussion about nesting the UIScrollView's but I really don't want to go there. Has anybody managed this with the standard UIScrollView (and works in the 2.2 and 3.0 SDK)? I don't fancy rolling my own zoom + bounce + pan + paging code.

    Read the article

  • Best ASP.NET E-Commerce Framework (aspDotNetStoreFront, AbleCommerce, BVCommerce, MediaChase,...)

    - by EfficionDave
    I need a full-featured asp.net E-Commerce solution for a project. It needs to be easily extensible as I need to extend it to integrate with a custom Flash based personalization engine. It should also have a great administrative back-end that handles inventory tracking, report, labels, shipping, ... so that the client can really use it as the basis for their business. I've used quite a few different E-Commerce systems including OSCommerce, Zen Cart, Catalook, and eTailer. While I was impressed with Zen Cart and eTailer, this project is big enough that I want to try a more serious, commercial offering. I'm particularly interested in thoughts on aspdotnetstorefront, BVCommerce, AbleCommerce, and MediaChase. [UPDATE] I've done quite a bit of evaluation since I posted this question and will give some of my findings below: BVCommerce - The price point is nice, the product seems fairly well regarded, and I've heard good things about customizing/extending it, it just doesn't seem like it's going to meet my needs as an Top Tier ECommerce solution. After viewing the tutorial videos, the Admin interface just seems too basic and outdated. aspDotNetStorefront - The integration with DotNetNuke was it's biggest selling point for me but after reading peoples opinions, it's integration seems quite weak. It's sounds like there's a significant learning curve and the architecture just doesn't sound like it's as clean as it should be. AbleCommerce - After a rather thorough evaluation, I have selected AbleCommerce for at least my next project. The Admin interface is beautiful and has a nice list of features. The E-Commerce portion of the user side is very well done, highly skin-able (using Master Pages and a couple other techniques), and the checkout workflow has all the features I need while still being very clean. Source to the API can be bought for $500 but you generally won't need it. There are some 3rd party modules available but there's not currently a large market for these. The biggest glaring weakness of AbleCommerce I've found is their CMS capabilities are very limited and not at all well suited for a non-technical user to make most site content updates. But I have a good solution for that that I plan adapting into AbleCommerce. They will automatically generate a site for you to play with to your heart's content for 30 days. It is defniitely worth checking out.

    Read the article

  • UML assignment question

    - by waitinforatrain
    Hi guys, Sorry, I know this is a very lame question to ask and not of any use to anyone else. I have an assignment in UML due tomorrow and I don't even know the basics (all-nighter ahead!). I'm not looking for a walkthrough, I simply want your opinion on something. The assignment is as follows (you only need to skim over it!): ============= Gourmet Surprise (GS) is a small catering firm with five employees. During a typical weekend, GS caters fifteen events with twenty to fifty people each. The business has grown rapidly over the past year and the owner wants to install a new computer system for managing the ordering and buying process. GS has a set of ten standard menus. When potential customers call, the receptionist describes the menus to them. If the customer decides to book an event (dinner, lunch, picnic, finger food etc.), the receptionist records the customer information (e.g., name, address, phone number, etc.) and the information about the event (e.g., place, date, time, which one of the standard menus, total price) on a contract. The customer is then faxed a copy of the contract and must sign and return it along with a deposit (often a credit card or by check) before the event is officially booked. The remaining money is collected when the catering is delivered. Sometimes, the customer wants something special (e.g., birthday cake). In this case, the receptionist takes the information and gives it to the owner who determines the cost; the receptionist then calls the customer back with the price information. Sometimes the customer accepts the price, other times, the customer requests some changes that have to go back to the owner for a new cost estimate. Each week, the owner looks through the events scheduled for that weekend and orders the supplies (e.g., plates) and food (e.g., bread, chicken) needed to make them. The owner would like to use the system for marketing as well. It should be able to track how customers learned about GS, and identify repeat customers, so that GS can mail special offers to them. The owner also wants to track the events on which GS sent a contract, but the customer never signed the contract and actually booked a GS. Exercise: Create an activity diagram and a use case model (complete with a set of detail use case descriptions) for the above system. Produce an initial domain model (class diagram) based on these descriptions. Elaborate the use cases into sequence diagrams, and include any state diagrams necessary. Finally use the information from these dynamic models to expand the domain model into a full application model. ============= In your opinion, do you think this question is asking me to come up with a package for an online ordering system to replace the system described above, or to create UML diagrams that facilitate the existing telephone-based system?

    Read the article

  • Clickable widgets in android

    - by Leif Andersen
    The developer documentation has seemed to have failed me here. I can create a static widget without thinking, I can even create a widget like the analogue clock widget that will update itself, however, I can not for the life of me figure out how to create a widget that reacts to when a user clicks on it. Here is the best code sample that the developer documentation gives to what a widget activity should contain (the only other hint being the API demos, which only creates a static widget): public class ExampleAppWidgetProvider extends AppWidgetProvider { public void onUpdate(Context context, AppWidgetManager appWidgetManager, int[] appWidgetIds) { final int N = appWidgetIds.length; // Perform this loop procedure for each App Widget that belongs to this provider for (int i=0; i<N; i++) { int appWidgetId = appWidgetIds[i]; // Create an Intent to launch ExampleActivity Intent intent = new Intent(context, ExampleActivity.class); PendingIntent pendingIntent = PendingIntent.getActivity(context, 0, intent, 0); // Get the layout for the App Widget and attach an on-click listener to the button RemoteViews views = new RemoteViews(context.getPackageName(), R.layout.appwidget_provider_layout); views.setOnClickPendingIntent(R.id.button, pendingIntent); // Tell the AppWidgetManager to perform an update on the current App Widget appWidgetManager.updateAppWidget(appWidgetId, views); } } } from: The Android Developer Documentation's Widget Page So, it looks like pending intent is called when the widget is clicked, which is based off of an intent (I'm not quite sure what the difference between an intent and a pending intent is), and the intent is for the ExampleActivity class. So I made my sample activity class a simple activity that when created, would create a mediaplayer object, and start it (it wouldn't ever release the object, so it would eventually crash, here is it's code: @Override public void onCreate(Bundle savedInstanceState) { super.onCreate(savedInstanceState); MediaPlayer mp = MediaPlayer.create(getApplicationContext(), R.raw.sound); mp.start(); } However, when I added the widget to the home screen, and clicked on it, nothing played, in fact, nothing played when I set the update timer to just a few hundred milliseconds (in the appwidget provider xml file). Furthermore, I set break points and found out that not only was it never reaching the activity, but no break points I set would ever get triggered. (I still haven't figured out why that is), however, logcat seemed to indicate that the activity class file was being run. So, is there anything I can do to get an appwidget to respond to a click? As the onClickPendingIntent() method is the closest I have found to a onClick type of method. Thank you very much.

    Read the article

< Previous Page | 345 346 347 348 349 350 351 352 353 354 355 356  | Next Page >