Search Results

Search found 26195 results on 1048 pages for 'process explorer'.

Page 35/1048 | < Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >

  • Using SQL Sentry Plan Explorer

    - by fatherjack
    LiveJournal Tags: How To,SSMS,Tips and tricks,Execution Plans This is a quick tip that I hope will help you use SQL Sentry's Plan Explorer tool. It's a really great tool for viewing Execution Plans - something that SSMS isn't too great at. If you don't have the tool then you can download it for free from http://www.sqlsentry.net/plan-explorer/sql-server-query-view.asp. So, just a little setup is required before I can show you the tip in full. Create a directory on your Desktop called Execution...(read more)

    Read the article

  • Attach to Process in Visual Studio

    - by Daniel Moth
    One option for achieving step 1 in the Live Debugging process is attaching to an already running instance of the process that hosts your code, and this is a good place for me to talk about debug engines. You can attach to a process by selecting the "Debug" menu and then the "Attach To Process…" menu in Visual Studio 11 (Ctrl+Alt+P with my keyboard bindings), and you should see something like this screenshot: I am not going to explain this UI, besides being fairly intuitive, there is good documentation on MSDN for the Attach dialog. I do want to focus on the row of controls that starts with the "Attach to:" label and ends with the "Select..." button. Between them is the readonly textbox that indicates the debug engine that will be used for the selected process if you click the "Attach" button. If you haven't encountered that term before, read on MSDN about debug engines. Notice that the "Type" column shows the Code Type(s) that can be detected for the process. Typically each debug engine knows how to debug a specific code type (the two terms tend to be used interchangeably). If you click on a different process in the list with a different code type, the debug engine used will be different. However note that this is the automatic behavior. If you believe you know best, or more typically you want to choose the debug engine for a process using more than one code type, you can do so by clicking the "Select..." button, which should yield a "Select Code Type" dialog like this one: In this dialog you can switch to the debug engine you want to use by checking the box in front of your desired one, then hit "OK", then hit "Attach" to use it. Notice that the dialog suggests that you can select more than one. Not all combinations work (you'll get an error if you select two incompatible debug engines), but some do. Also notice in the list of debug engines one of the new players in Visual Studio 11, the GPU debug engine - I will be covering that on the C++ AMP team blog (and no, it cannot be combined with any others in this release). Comments about this post by Daniel Moth welcome at the original blog.

    Read the article

  • Démonstration vidéo des nouvelles fonctionnalités d'Internet Explorer 9, par Stanislas Quastana de Microsoft France

    Démonstration vidéo des nouvelles fonctionnalités d'Internet Explorer 9, par Stanislas Quastana de Microsoft France Mise à jour du 14.02.2011 par Katleen A l'occasion ds TechDays, et avant la sortie de la RC, Stanislas Quastana, Architecte Infrastructure sur la plateforme serveur chez Microsoft France, a réalisé une démonstration des nouvelles fonctionnalités du navigateur, en exclusivité pour Developpez.com. A regarder de toute urgence : Démonstration d'Internet Explorer 9 par Microsoft on...

    Read the article

  • How to Open an InPrivate Tab in the Metro Version of Internet Explorer

    - by Taylor Gibb
    Internet Explorer has a secret mode called InPrivate which is pretty much the same as Chrome’s incognito mode. It can be accessed on the desktop by right-clicking on the Internet Explorer icon on the taskbar, but how do you open an InPrivate tab in the Metro IE? Read on to find out. HTG Explains: Is ReadyBoost Worth Using? HTG Explains: What The Windows Event Viewer Is and How You Can Use It HTG Explains: How Windows Uses The Task Scheduler for System Tasks

    Read the article

  • Internet Explorer 10 moins vulnérable que ses concurrents, Microsoft détaille les fonctions de sécurité du navigateur

    Internet Explorer 10 moins vulnérable que ses concurrents Microsoft détaille les fonctions de sécurité du navigateurLe mois dernier, une étude du cabinet NSS Labs a montré qu'Internet Explorer 10 était plus sûr que n'importe lequel de ses concurrents, en ce qui concerne la protection des utilisateurs contre les téléchargements dangereux.L'analyse, portant essentiellement sur la fonction SmartScreen du navigateur, a permis de constater qu'IE 10 sous Windows 8 était capable de bloquer près de 99,96 % des téléchargements de programmes malveillants.Le navigateur dispose cependant de plusieurs autres évolutions dans le domaine de la s...

    Read the article

  • Google sortira des plug-ins pour Safari et Internet Explorer afin que ceux-ci supportent WebM

    Google sortira des plug-ins pour Safari et Internet Explorer Afin que ceux-ci supportent WebM Google annonce qu'il va bientôt sortir des plug-ins pour Safari et Internet Explorer qui permettront à ces navigateurs de supporter les vidéos au format WebM. Cette annonce fait suite à de nombreuses critiques qu'auraient reçu la firme après sa décision d'abandonner la prise en charge du codec video H.264 dans son navigateur Google Chrome. Pour mémoire la firme avait annoncé il y a juste quelque jours l'arrêt d...

    Read the article

  • Hiding System Objects in Object Explorer in SQL Server Management Studio

    While looking through the new features and improvements in SQL Server Management Studio (SSMS) we found a potentially interesting one to Hide System Objects in Object Explorer in SQL Server Management Studio. In this tip we will take a look at how to Hide System Objects in Object Explorer. Join SQL Backup’s 35,000+ customers to compress and strengthen your backups "SQL Backup will be a REAL boost to any DBA lucky enough to use it." Jonathan Allen. Download a free trial now.

    Read the article

  • Streamline Your Complete SEO Process

    Everyone has their own way of doing SEO, and that's the better way to do it. But, streamlining your SEO process will make your SEO process to run successfully. By streamlining your SEO process, you and your clients benefit when your SEO process is faster, and more efficient.

    Read the article

  • Using Site Explorer to Improve Yahoo Search Results

    It is the information generated within Yahoo Site Explorer, and the interpretation of that valuable data, that provides the necessary direction; to improve your Yahoo search results. As with any tool, Site Explorer must be used properly and effectively; to be beneficial.

    Read the article

  • Windows Phone 7 Isolated Storage Explorer

    - by help.net
    WP7 Isolated Storage Explorer is a tool designed to help developers and testers interact with the isolated storage file for Silverlight Windows Phone 7 applications. The explorer can work both as a desktop application for testers or integrated in Visual Studio for developers. Whenever a WP7 application/project involves storing data locally the the device, it will be to the isolated storage file. A common difficulty is accessing the data for testing or rapidly restoring the application's data/state...(read more)

    Read the article

  • "Utiliser Internet Explorer 6, c'est comme boire du lait périmé", déclare Microsoft dans une campagn

    Mise à jour du 17.05.2010 par Katleen "Utiliser Internet Explorer 6, c'est comme boire du lait périmé", déclare Microsoft dans une campagne demandant la migration vers IE8 Microsoft Australie frappe fort avec une campagne publicitaire dissuasive, qui vise mettre un frein voir stopper l'utilisation de l'un de ses anciens produits : Internet Explorer 6. L'éditeur conseille la migration vers la version 8, qu'il considère comme le navigateur le plus sécurisé du marché. Bien que le support d'IE6 soit assuré jusqu'en 201...

    Read the article

  • JAMES Mailet development process

    - by itsadok
    I'm starting a project that involves writing mailets for Apache James. As far as I can tell, the only way to test a change in my code (on Windows) is through the following steps: Compile the mailet code Build a jar file containing the mailet Copy the jar file into the apps/james/SAR-INF/lib directory Start JAMES from run.bat Run test Stop JAMES by telneting to port 4555 and issuing a shutdown command (I guess on Linux a SIGTERM would suffice) I can automate all these steps using Ant and some scripting magic, but I was wondering if I was missing something. Does anyone here have experience developing mailets? Did you use a similar process, or is there an easier way? For example, is there a way to make a running James instance reload the mailets JAR?

    Read the article

  • Java process inputstream in thread

    - by Norbiprog
    Hi! I develop an Eclipse plugin and I have a problem My code is the following one: String run_pelda = "cmd.exe /C pelda.exe"; Runtime pelda_rt = Runtime.getRuntime(); Process pelda_proc = javacheckgen_rt.exec(run_pelda); And after I would like to read the inputstream: InputStream toolstr = tool_proc.getInputStream(); InputStreamReader r = new InputStreamReader(toolstr); BufferedReader in = new BufferedReader(r); But my new Eclipse instsnce doesn't work. I think I should do it in java threads, but unfortunatelly I don't know to use it correctly. Please give me some ideas!

    Read the article

  • What process does professional website building follow?

    - by Sivvy
    I've searched for a while, but I can't find anything related on Google or here. Me and some friends were debating starting a company, so I figure it might be good to do a quick pilot project to see how well we can work together. We have a designer who can do HTML, CSS and Flash, enjoys doing art, but doesn't like to do HTML and CSS... And 2 programmers that are willing to do anything. My question is, from an experienced site builder's perspective, what steps do we do - in chronological order - to properly handle a website? Does the designer design the look and feel of the site, then the programmers fill in the gaps with functionality? Or do the programmers create a "mock-up" of the site with most of the functionality, then the designer spices it up? Or is it more of a back-and-forth process? I just want to know how a professional normally handles it.

    Read the article

  • Using Unix Process Controll Methods in Ruby

    - by John F. Miller
    Ryan Tomayko touched off quite a fire storm with this post about using Unix process control commands. We should be doing more of this. A lot more of this. I'm talking about fork(2), execve(2), pipe(2), socketpair(2), select(2), kill(2), sigaction(2), and so on and so forth. These are our friends. They want so badly just to help us. I have a bit of code (a delayed_job clone for DataMapper that I think would fit right in with this, but I'm not clear on how to take advantage of the listed commands. Any Ideas on how to improve this code? def start say "*** Starting job worker #{@name}" t = Thread.new do loop do delay = Update.work_off(self) break if $exit sleep delay break if $exit end clear_locks end trap('TERM') { terminate_with t } trap('INT') { terminate_with t } trap('USR1') do say "Wakeup Signal Caught" t.run end end

    Read the article

  • is there any cross platform process manager tool

    - by lvlv
    I need a program that is able to launch a set of processes according to a schedule/configuration; the program would run in the background and restart the processes in case they crash. There are standard tools for this kind of task on both windows and unix - what I need is a cross platform program which could run on different operating systems using the same configuration. A portable C/C++ library which implements the basic functionality (i.e. create processes, signal process termination events and all that) would be ok too.

    Read the article

  • Connect to an existing process

    - by user360807
    Hole thing is happening on the mac os x. Let's assume that I've opened an program by clicking on an .app icon. It's a python program with GUI which has a separate process that waits for a user input. But as I've opened it by clickin .app icon I dont have access to it's input as I would have if I opened it in Terminal. And the question is: How can I connect new Terminal window to this running program? I tried pipes but I'm not sure how to use them correctly. My guess was to find PID of the app that is running and then pipe to this program by giving a PID. But I have no idea how to do it. I hope you were able to understand what's the problem. Sorry for my weak english :)

    Read the article

  • Your Django Development process/steps (Step by Step)

    - by AJ
    I want to know step by step process of how folks develop on Django here. I have seen that whenever I try to create a website in Django, I always get confused amongst: DB Schema/models.py UI/Template Structure Login module urls.py views.py How do you approach this? I may have missed something. You do not need to elaborate everything, just stepwise what you do. If you do two things at the same time (or side-by-side), that would also be helpful to mention. Thanks a lot.

    Read the article

  • long running process in asp.net C#

    - by user339323
    Hello All, I have a web application that has a long running (resource intensive) process in the code behind and the end output is a pdf file (images to pdf conversion tool) It runs fine..and since I am on a dedicated server, it is not at all a problem with respect to resources right now. However, I wonder that the system would reach its resource limits if, there are more than 20 users processing at a time. I have seen services online where the user enters their email and the processes are, I suppose, queued in the background and the results emailed with the 1st in 1st out method. Can someone please give me a start on how to implement this kind of logic in asp.net applications using C#? Thanks a lot in advance, Prasad.

    Read the article

  • Activity monitor doesnt display process name

    - by Mohsin Khawas
    Hi, I have an application, when I see that application in "Activity Monitor" the applications Process Name is displayed nothing. Only the application icon is displayed. I tried debugging this by getting processInfo of the app, I got the application name correct. Even tried with the "top" command, I got the application name correct. The target name and settings also shows the same, only the activity monitor got wrong. Is it something I missed so that activity monitor is displaying nothing. M

    Read the article

  • Build Process failed with maven package

    - by vijay.shad
    Hi I am working on a maven project to build a simple utility api. The same source code when build on my office win XP machine, was successful. Now i am at home and working with same source code on CentOS machine. Here the build process failed strangely. The error it reports is ideally in my points should we warning message. As shown below. [ERROR] com.vsd.Provider:[12,240] The import java.util.Set is never used Can you please give me some idea, where can I look into?

    Read the article

  • Process.Exited event is not be called

    - by liys
    Hi all, I have the following code snippet to call into command line: p = new Process(); ProcessStartInfo psi = new ProcessStartInfo(); psi.FileName = "cmd.exe"; psi.Arguments = "/C " + "type " + “[abc].pdf”; psi.UseShellExecute = false; psi.RedirectStandardInput = false; psi.RedirectStandardOutput = true; psi.CreateNoWindow = true; p.StartInfo = psi; p.EnableRaisingEvents = true; p.Exited += new EventHandler(p_Exited); p.Start(); p.WaitForExit(); Strangely, When [abc] is a small pdf file(8kb) p_Exited is called. But when it's a large pdf file(120kb) it is never called. Any clues? Thanks,

    Read the article

  • WINSDK: Determining whether an arbitrary pid identifies a running process on Windows

    - by Vlad Romascanu
    Attempting to implement a poor man's test of whether a process is still running or not (essentially an equivalent of the trivial kill(pid, 0).) Hoped to be able to simply call OpenProcess with some minimal desired access then test for either GetLastError() == ERROR_INVALID_PARAMETER or GetExitCodeProcess(...) != STILL_ACTIVE. Nice try... Running on Windows XP, as administrator: HANDLE hProc = OpenProcess(PROCESS_QUERY_INFORMATION, FALSE, pid); if (!hProc) { DWORD dwLastError = GetLastError(); } ...fails miserably with dwLastError == ERROR_ACCESS_DENIED when pid is owned by a different (not SYSTEM) user. Moreover, if pid was originally owned by a different user but has since terminated, OpenProcess also fails with ERROR_ACCESS_DENIED (not ERROR_INVALID_PARAMETER.) Do I have to use Process32First/Process32Next or EnumProcesses? I absolutely do not want to use SeDebugPrivilege. Thanks, V

    Read the article

  • Creating new process with Lua interpreater, failures in passing argumets

    - by user1131997
    I need help with passing arguments in CreateProcess() //Windows I want to: BOOL status = CreateProcess(L"C:\\Program Files (x86)\\Lua\\lua52.exe", NULL, NULL, NULL, FALSE, NULL, NULL, NULL, &si, &pi); But with passing some arguments.... Lua interpreater accepts file with lua-scripts, so I have prepared it and want to do: lua52 C:\1.lua for example... I have the path of some lua-script and want the interpreater of Lua to interpreate it and than get the result of program on Lua from Created process. I have tried in some ways to do it, but no success. Please, help! Thank you!

    Read the article

< Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >