Search Results

Search found 99890 results on 3996 pages for 'sql server ce'.

Page 35/3996 | < Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >

  • Why upgrade from SQL 2005 to SQL 2008 R2?

    - by GordyII
    have been tasked to write a document outlining the best reasons to use SQL 2008 R2 instead of SQL 2005 for my brand new BI project. We have a policy of only using two versions at a time and there are still SQL 2000 boxes around here somewhere.... I know the microsoft line on as per this link. http://www.microsoft.com/sqlserver/2008/en/us/why-upgrade.aspx What I want to know is your opinions of which are the best features and why. So if you can help me try to convince management to use a product which is actually up to date, I would appreciate it.

    Read the article

  • SharePoint 2010 – SQL Server has an unsupported version 10.0.2531.0

    - by Jeff Widmer
    I am trying to perform a database attach upgrade to SharePoint Foundation 2010. At this point I am trying to attach the content database to a Web application by using Windows Powershell: Mount-SPContentDatabase -Name <DatabaseName> -DatabaseServer <ServerName> -WebApplication <URL> [-Updateuserexperience] I am following the directions from this TechNet article: Attach databases and upgrade to SharePoint Foundation 2010.  When I go to mount the content database I am receiving this error: Mount-SPContentDatabase : Could not connect to [DATABASE_SERVER] using integrated security: SQL server at [DATABASE_SERVER] has an unsupported version 10.0.2531.0. Please refer to “http://go.microsoft.com/fwlink/?LinkId=165761” for information on the minimum required SQL Server versions and how to download them. At first this did not make sense because the default SharePoint Foundation 2010 website was running just fine.  But then I realized that the default SharePoint Foundation site runs off of SQL Server Express and that I had just installed SQL Server Web Edition (since the database is greater than 4GB) and restored the database to this version of SQL Server. Checking the documentation link above I see that SharePoint Server 2010 requires a 64-bit edition of SQL Server with the minimum required SQL Server versions as follows: SQL Server 2008 Express Edition Service Pack 1, version number 10.0.2531 SQL Server 2005 Service Pack 3 cumulative update package 3, version number 9.00.4220.00 SQL Server 2008 Service Pack 1 cumulative update package 2, version number 10.00.2714.00 The version of SQL Server 2008 Web Edition with Service Pack 1 (the version I installed on this machine) is 10.0.2531.0. SELECT @@VERSION: Microsoft SQL Server 2008 (SP1) - 10.0.2531.0 (X64)   Mar 29 2009 10:11:52   Copyright (c) 1988-2008 Microsoft Corporation  Web Edition (64-bit) on Windows NT 6.1 <X64> (Build 7600: ) (VM) But I had to read the article several times since the minimum version number for SQL Server Express is 10.0.2531.0.  At first I thought I was good with the version of SQL Server 2008 Web that I had installed, also 10.0.2531.0.  But then I read further to see that there is a cumulative update (hotfix) for SQL Server 2008 SP1 (NOT the Express edition) that is required for SharePoint 2010 and will bump the version number to 10.0.2714.00. So the solution was to install the Cumulative update package 2 for SQL Server 2008 Service Pack 1 on my SQL Server 2008 Web Edition to allow SharePoint 2010 to work with SQL Server 2008 (other than the SQL Server 2008 Express version). SELECT @@VERSION (After installing Cumulative update package 2): Microsoft SQL Server 2008 (SP1) - 10.0.2714.0 (X64)   May 14 2009 16:08:52   Copyright (c) 1988-2008 Microsoft Corporation  Web Edition (64-bit) on Windows NT 6.1 <X64> (Build 7600: ) (VM)

    Read the article

  • The perils of double-dash comments [T-SQL]

    - by jamiet
    I was checking my Twitter feed on my way in to work this morning and was alerted to an interesting blog post by Valentino Vranken that highlights a problem regarding the OLE DB Source in SSIS. In short, using double-dash comments in SQL statements within the OLE DB Source can cause unexpected results. It really is quite an important read if you’re developing SSIS packages so head over to SSIS OLE DB Source, Parameters And Comments: A Dangerous Mix! and be educated. Note that the problem is solved in SSIS2012 and Valentino explains exactly why. If reading Valentino’s post has switched your brain into “learn mode” perhaps also check out my post SSIS: SELECT *... or select from a dropdown in an OLE DB Source component? which highlights another issue to be aware of when using the OLE DB Source. As I was reading Valentino’s post I was reminded of a slidedeck by Chris Adkin entitled T-SQL Coding Guidelines where he recommends never using double-dash comments: That’s good advice! @Jamiet

    Read the article

  • Database Mirroring of SQL server

    - by jbp117
    I have two databases that are mirrored to another server using database mirroring. The mirror server has to be down for some reason for few days. Now the production server is having principal databases in (PRINCIPAL/DISCONNECTED) State. Clients can access those databases. So what happens when they keep on adding data to these databases?? Will the data get committed or waits till the mirror comes up?

    Read the article

  • SSIS: Building SQL databases on-the-fly using concatenated SQL scripts

    - by DrJohn
    Over the years I have developed many techniques which help automate the whole SQL Server build process. In my current process, where I need to build entire OLAP data marts on-the-fly, I make regular use of a simple but very effective mechanism to concatenate all the SQL Scripts together from my SSMS (SQL Server Management Studio) projects. This proves invaluable because in two clicks I can redeploy an entire SQL Server database with all tables, views, stored procedures etc. Indeed, I can also use the concatenated SQL scripts with SSIS to build SQL Server databases on-the-fly. You may be surprised to learn that I often redeploy the database several times per day, or even several times per hour, during the development process. This is because the deployment errors are logged and you can quickly see where SQL Scripts have object dependency errors. For example, after changing a table structure you may have forgotten to change any related views. The deployment log immediately points out all the objects which failed to build so you can fix and redeploy the database very quickly. The alternative approach (i.e. doing changes in the database directly using the SSMS UI) would require you to check all dependent objects before making changes. The chances are that you will miss something and wonder why your app returns the wrong data – a common problem caused by changing a table without re-creating dependent views. Using SQL Projects in SSMS A great many developers fail to make use of SQL Projects in SSMS (SQL Server Management Studio). To me they are invaluable way of organizing your SQL Scripts. The screenshot below shows a typical SSMS solution made up of several projects – one project for tables, another for views etc. The key point is that the projects naturally fall into the right order in file system because of the project name. The number in the folder or file name ensures that the projects the SQL scripts are concatenated together in the order that they need to be executed. Hence the script filenames start with 100, 110 etc. Concatenating SQL Scripts To concatenate the SQL Scripts together into one file, I use notepad.exe to create a simple batch file (see example screenshot) which uses the TYPE command to write the content of the SQL Script files into a combined file. As the SQL Scripts are in several folders, I simply use several TYPE command multiple times and append the output together. If you are unfamiliar with batch files, you may not know that the angled bracket (>) means write output of the program into a file. Two angled brackets (>>) means append output of this program into a file. So the command-line DIR > filelist.txt would write the content of the DIR command into a file called filelist.txt. In the example shown above, the concatenated file is called SB_DDS.sql If, like me you place the concatenated file under source code control, then the source code control system will change the file's attribute to "read-only" which in turn would cause the TYPE command to fail. The ATTRIB command can be used to remove the read-only flag. Using SQLCmd to execute the concatenated file Now that the SQL Scripts are all in one big file, we can execute the script against a database using SQLCmd using another batch file as shown below: SQLCmd has numerous options, but the script shown above simply executes the SS_DDS.sql file against the SB_DDS_DB database on the local machine and logs the errors to a file called SB_DDS.log. So after executing the batch file you can simply check the error log to see if your database built without a hitch. If you have errors, then simply fix the source files, re-create the concatenated file and re-run the SQLCmd to rebuild the database. This two click operation allows you to quickly identify and fix errors in your entire database definition.Using SSIS to execute the concatenated file To execute the concatenated SQL script using SSIS, you simply drop an Execute SQL task into your package and set the database connection as normal and then select File Connection as the SQLSourceType (as shown below). Create a file connection to your concatenated SQL script and you are ready to go.   Tips and TricksAdd a new-line at end of every fileThe most common problem encountered with this approach is that the GO statement on the last line of one file is placed on the same line as the comment at the top of the next file by the TYPE command. The easy fix to this is to ensure all your files have a new-line at the end.Remove all USE database statementsThe SQLCmd identifies which database the script should be run against.  So you should remove all USE database commands from your scripts - otherwise you may get unintentional side effects!!Do the Create Database separatelyIf you are using SSIS to create the database as well as create the objects and populate the database, then invoke the CREATE DATABASE command against the master database using a separate package before calling the package that executes the concatenated SQL script.    

    Read the article

  • How to create SQL Server Express DB from SQL Server DB

    - by jeff
    I have a SQL Server 2008 DB. I want to extract SOME tables (and associated schema, constraints, indexes, etc) and create a SQL Server Express DB. It isn't a sync of the target, we stomp on it. We ONLY need to do this in the file system (not across the wire). We are not fond of the synchronization stuff and at this point don't know how to run SSIS. We are a C# shop and a little code is ok. Like using the C# bulk import stuff, but that won't create the schema. Suggestions?

    Read the article

  • SQL Server v.Next (Denali) : More on contained databases and "contained users"

    - by AaronBertrand
    One of the reasons for contained databases (see my previous post ) is to allow for a more seamless transition when moving a database from one server to another. One of the biggest complications in doing so is making sure that all of the logins are in place on the new server. Contained databases help solve this issue by creating a new type of user: a database-level user with a password. I want to stress that this is not the same concept as a user without a login , which serves a completely different...(read more)

    Read the article

  • SQL Server Master class winner

    - by Testas
     The winner of the SQL Server MasterClass competition courtesy of the UK SQL Server User Group and SQL Server Magazine!    Steve Hindmarsh     There is still time to register for the seminar yourself at:  www.regonline.co.uk/kimtrippsql     More information about the seminar     Where: Radisson Edwardian Heathrow Hotel, London  When: Thursday 17th June 2010  This one-day MasterClass will focus on many of the top issues companies face when implementing and maintaining a SQL Server-based solution. In the case where a company has no dedicated DBA, IT managers sometimes struggle to keep the data tier performing well and the data available. This can be especially troublesome when the development team is unfamiliar with the affect application design choices have on database performance. The Microsoft SQL Server MasterClass 2010 is presented by Paul S. Randal and Kimberly L. Tripp, two of the most experienced and respected people in the SQL Server world. Together they have over 30 years combined experience working with SQL Server in the field, and on the SQL Server product team itself. This is a unique opportunity to hear them present at a UK event which will: Debunk many of the ingrained misconceptions around SQL Server's behaviour    Show you disaster recovery techniques critical to preserving your company's life-blood - the data    Explain how a common application design pattern can wreak havoc in the database Walk through the top-10 points to follow around operations and maintenance for a well-performing and available data tier! Please Note: Agenda may be subject to change  Sessions Abstracts  KEYNOTE: Bridging the Gap Between Development and Production    Applications are commonly developed with little regard for how design choices will affect performance in production. This is often because developers don't realize the implications of their design on how SQL Server will be able to handle a high workload (e.g. blocking, fragmentation) and/or because there's no full-time trained DBA that can recognize production problems and help educate developers. The keynote sets the stage for the rest of the day. Discussing some of the issues that can arise, explaining how some can be avoided and highlighting some of the features in SQL 2008 that can help developers and DBAs make better use of SQL Server, and troubleshoot when things go wrong.   SESSION ONE: SQL Server Mythbusters  It's amazing how many myths and misconceptions have sprung up and persisted over the years about SQL Server - after many years helping people out on forums, newsgroups, and customer engagements, Paul and Kimberly have heard it all. Are there really non-logged operations? Can interrupting shrinks or rebuilds cause corruption? Can you override the server's MAXDOP setting? Will the server always do a table-scan to get a row count? Many myths lead to poor design choices and inappropriate maintenance practices so these are just a few of many, many myths that Paul and Kimberly will debunk in this fast-paced session on how SQL Server operates and should be managed and maintained.   SESSION TWO: Database Recovery Techniques Demo-Fest  Even if a company has a disaster recovery strategy in place, they need to practice to make sure that the plan will work when a disaster does strike. In this fast-paced demo session Paul and Kimberly will repeatedly do nasty things to databases and then show how they are recovered - demonstrating many techniques that can be used in production for disaster recovery. Not for the faint-hearted!   SESSION THREE: GUIDs: Use, Abuse, and How To Move Forward   Since the addition of the GUID (Microsoft’s implementation of the UUID), my life as a consultant and "tuner" has been busy. I’ve seen databases designed with GUID keys run fairly well with small workloads but completely fall over and fail because they just cannot scale. And, I know why GUIDs are chosen - it simplifies the handling of parent/child rows in your batches so you can reduce round-trips or avoid dealing with identity values. And, yes, sometimes it's even for distributed databases and/or security that GUIDs are chosen. I'm not entirely against ever using a GUID but overusing and abusing GUIDs just has to be stopped! Please, please, please let me give you better solutions and explanations on how to deal with your parent/child rows, round-trips and clustering keys!   SESSION 4: Essential Database Maintenance  In this session, Paul and Kimberly will run you through their top-ten database maintenance recommendations, with a lot of tips and tricks along the way. These are distilled from almost 30 years combined experience working with SQL Server customers and are geared towards making your databases more performant, more available, and more easily managed (to save you time!). Everything in this session will be practical and applicable to a wide variety of databases. Topics covered include: backups, shrinks, fragmentation, statistics, and much more! Focus will be on 2005 but we'll explain some of the key differences for 2000 and 2008 as well. Speaker Biographies     Kimberley L. Tripp Paul and Kimberly are a husband-and-wife team who own and run SQLskills.com, a world-renowned SQL Server consulting and training company. They are both SQL Server MVPs and Microsoft Regional Directors, with over 30 years of combined experience on SQL Server. Paul worked on the SQL Server team for nine years in development and management roles, writing many of the DBCC commands, and ultimately with responsibility for core Storage Engine for SQL Server 2008. Paul writes extensively on his blog (SQLskills.com/blogs/Paul) and for TechNet Magazine, for which he is also a Contributing Editor. Kimberly worked on the SQL Server team in the early 1990s as a tester and writer before leaving to found SQLskills and embrace her passion for teaching and consulting. Kimberly has been a staple at worldwide conferences since she first presented at TechEd in 1996, and she blogs at SQLskills.com/blogs/Kimberly. They have written Microsoft whitepapers and books for SQL Server 2000, 2005 and 2008, and are regular, top-rated presenters worldwide on database maintenance, high availability, disaster recovery, performance tuning, and SQL Server internals. Together they teach the SQL MCM certification and throughout Microsoft.In their spare time, they like to find frogfish in remote corners of the world.   Speaker Testimonials  "To call them good trainers is an epic understatement. They know how to deliver technical material in ways that illustrate it well. I had to stop Paul at one point and ask him how long it took to build a particular slide because the animations were so good at conveying a hard-to-describe process." "These are not beginner presenters, and they put an extreme amount of preparation and attention to detail into everything that they do. Completely, utterly professional." "When it comes to the instructors themselves, Kimberly and Paul simply have no equal. Not only are they both ultimate authorities, but they have endless enthusiasm about the material, and spot on delivery. If either ever got tired they never showed it, even after going all day and all week. We witnessed countless demos over the course of the week, some extremely involved, multi-step processes, and I can’t recall one that didn’t go the way it was supposed to." "You might think that with this extreme level of skill comes extreme levels of egotism and lack of patience. Nothing could be further from the truth. ... They simply know how to teach, and are approachable, humble, and patient." "The experience Paul and Kimberly have had with real live customers yields a lot more information and things to watch out for than you'd ever get from documentation alone." “Kimberly, I just wanted to send you an email to let you know how awesome you are! I have applied some of your indexing strategies to our website’s homegrown CMS and we are experiencing a significant performance increase. WOW....amazing tips delivered in an exciting way!  Thanks again” 

    Read the article

  • How do I add a self-referencing linked server in SQL 2008

    - by tigermain
    I am trying to replicate our live server set up local using a single SQL database. In SQL 2005 I would added 2 linked servers both referencing itself with different names, each point to a different table. How do I do this in SQL 2008. I've try the various providers and different parameters butto no avail. The local server is using a trusted connection so I dont need any usernames/passwords Im ideally need to set up the following linked references: DBSVR1 - mydb_master DBSVR2 - mydb_import Any light on the subject would help, I managed to do it in 2005 about 8 months ago but cant remember how, now Im in 2008!

    Read the article

  • SQL Server 2005, Sudden increase of connections - SharePoint 2007

    - by CrazyNick
    We observed that sudden increase of SQL connections during a specific hour, it is a backend of a SharePoint 2007 Farm. From SharePoint 2007 Perspective: 1. Incremental crawling is scheduled at that time and few of the Timer jobs (normal timer jobs) are scheduled to run every mins / per 10mins. 2. Number of user requests are less. From SQL Server 2005 Perspective: 1. Transaction log backup is scheduled at that time 2. No other scheduled jobs are running at that time. so, how to narrow down the issue, what would be causing the sudden SQL connection increase?

    Read the article

  • A quick note about the end of SQL Server 2005 mainstream support

    - by AaronBertrand
    In a previous blog post about Service Pack 4 , I said the following: "...from this point forward all you're likely to see are cumulative updates to the SP3 and SP4 branches and, roughly a year from today, mainstream support will only need to maintain the SP4 branch. You can read more about this in the following blog post from the CSS blog: Mainstream vs Extended Support and SQL Server 2005 SP4: Can someone explain all of this? " In that post, I focused on these words in the product lifecycle chart:...(read more)

    Read the article

  • SQL Server v.Next (Denali) : Troubleshooting Error 18456

    - by AaronBertrand
    I think we've all dealt with error 18456, whether it be an application unable to access SQL Server, credentials changing over time, or a user who can't type a password correctly. The trick to troubleshooting this error number is that the error message returned to the client or application trying to connect is intentionally vague (the error message is similar for most errors, and the state is always 1). In a few cases, some additional information is included, but for the most part several of these...(read more)

    Read the article

  • SQL Server v.Next ("Denali") : How a columnstore index is not like a normal index

    - by AaronBertrand
    At the end of my Denali presentation at SQL Saturday #65 in Vancouver, a member of the audience asked, "What makes a columnstore index different from a regular nonclustered index?" At the end of a busy day, I was at a loss for an answer, and I'll explain why. First, I'll briefly explain the basic, core, high-level functionality of a columnstore index (you can read a lot more details in this white paper ). Basically, instead of storing index data together on a page, it divvies up the data from each...(read more)

    Read the article

  • SQL Server v.Next (Denali) : Metadata enhancements

    - by AaronBertrand
    In my previous job, we had several cases where schema changes or incorrect developer assumptions in the middle tier or application logic would lead to type mismatches. We would have a stored procedure that returns a BIT column, but then change the procedure to have something like CASE WHEN <condition> THEN 1 ELSE 0 END. In this case SQL Server would return an INT as a catch-all, and if .NET was expecting a boolean, BOOM. Wouldn't it be nice if the application could check the result set of the...(read more)

    Read the article

  • View all ntext column text in SQL Server Management Studio for SQL CE database

    - by Dave
    I often want to do a "quick check" of the value of a large text column in SQL Server Management Studio (SSMS). The maximum number of characters that SSMS will let you view, in grid results mode, is 65535. (It is even less in text results mode.) Sometimes I need to see something beyond that range. Using SQL Server 2005 databases, I often used the trick of converting it to XML, because SSMS lets you view much larger amounts of text that way: SELECT CONVERT(xml, MyCol) FROM MyTable WHERE ... But now I am using SQL CE, and there is no Xml data type. There is still a "Maximum Characters Retreived XML" value under Options; I suppose this is useful when connecting to other data sources. I know I can just get the full value by running a little console app or something, but is there a way within SSMS to see the entire ntext column value? [Edit] OK, this didn't get much attention the first time around (18 views?!). It's not a huge concern, but maybe I'm just obsessed with it. There has to be some good way around this, doesn't there? So a modest bounty is active. What I am willing to accept as answers, in order from best-to-worst: A solution that works just as easy as the XML trick in SQL CE. That is, a single function (convert, cast, etc.) that does the job. A not-too-invasive way to hack SSMS to get it to display more text in the results. An equivalent SQL query (perhaps something that creatively uses SUBSTRING and generates multiple ad-hoc columns??) to see the results. The solution should work with nvarchar and ntext columns of any length in SQL CE from SSMS. Any ideas?

    Read the article

  • Managing SQL Server users via Active directory groups

    - by hyty
    I'm building SQL Server instance for reporting purposes. My plan is to use AD groups for server and database logins. I have several groups with different roles (admin, developer, user etc.), and I would like to map these roles into SQL Server database roles (db_owner, db_datawriter etc.). What are the pros and cons of using AD groups for logins? What kind of problems you have noticed?

    Read the article

  • Linked server problem on SQL Server 2005

    - by BradyKelly
    I have a weird issue and I hope someone can steer me in the right direction for resolving this please. When I execute the following query against a linked server, I get the following error. I can connect to the server in SSMS as a separate server, and execute a similar query against its Deposits table. The nn.nn is my own replacement to avoid broadcasting our server addresses. The query: select td.Batch , td.DateTimeDeposited from Deposits cd left join [172.nn.nn.32\sqlexpress].Terminal.dbo.Deposits td on cd.DateTimeDeposited = td.DateTimeDeposited The error: OLE DB provider "SQLNCLI" for linked server "172.nn.nn.11\sqlexpress" returned message "Login timeout expired". OLE DB provider "SQLNCLI" for linked server "172.nn.nn.11\sqlexpress" returned message "An error has occurred while establishing a connection to the server. When connecting to SQL Server 2005, this failure may be caused by the fact that under the default settings SQL Server does not allow remote connections.". Msg 65535, Level 16, State 1, Line 0 SQL Network Interfaces: Error Locating Server/Instance Specified [xFFFFFFFF]. Notice how the error is about server 172.nn.nn.11 and not 172.nn.nn.32. SOLVED (STUPID ME): Somebody had added an extra bit to my query that was scrolled off-screen and was querying the 17.nn.nn.11 server.

    Read the article

  • Can't access SQL Server 2008 from workstations, but can from server

    - by Kev
    We have an app that can use mssql2k or 2k8. We've been using 2k but I decided to try 2k8 to compare. I installed in on our win2k3 server alongside mssql2k. In the ODBC applet on the server, I was able to set up access to 2k8, and it passes the test at the end successfully, whether I tell it to use Windows Authentication or an sql login. The latter is how the app always accessed mssql2k. The app works fine from the server, but when I try it on a workstation (winxpsp3), I get a window titled, "Microsoft SQL Server Login" that says: Connection failed: SQLState: '01000' SQL Server Error: 53 [Microsoft][ODBC SQL Server Driver][DBNETLIB]ConnectionOpen (Connect()). Connection failed: SQLState: '08001' SQL Server ERror: 17 [Microsoft][ODBC SQL Server Driver][DBNETLIB]SQL Server does not exist or access denied. Then I get the ODBC login dialog, which I can't get to login correctly (I just keep getting the same error above), even copying and pasting a password after resetting it on the server, and whether "trusted" is checked or not. "Options" is disabled. The server was straight SERVERNAME for mssql2k, but for mssql2k8 it's called SERVERNAME\mssql2008. That works on the server, why not on the workstation? (Which I'm logged in as the same person on, BTW.)

    Read the article

  • HTTP Push from SQL Server — Comet SQL

    Article provides example solution for presenting data in "real-time" from Microsoft SQL Server in HTML browser. Article presents how to implement Comet functionality in ASP.NET and how to connect Comet with Query Notification from SQL Server.

    Read the article

  • SQL 2008 Replication corrupt data problem

    - by Jonathan K
    We took a SQL 2000 database. Took a lightspeed backup. Restored on SQL 2008 active/passive cluster. Then setup replication to replicate the data back to SQL 2000. So 2008 is the publisher/distributor, and 2000 is doing a pull subscription. Everything works well, execpt we occassionally get corrupt data in varchar/text fields on the subscriber. So for example we have a table with 4500 records. When we run this statement: update MedstaffProvider set Notes = 'Cell Phone: 360.123.4567 Answering Service: 360.123.9876' where LastName = 'smith' The record in the 2008 database is updated as expected. But in the subsriber datbase we'll get gibberish in the notes field: óPÌ[1] T $Oé[1] ð²ñ. K Here's what we know: This is repeatable, meaning we can run that same query all day long and get the same gibberish. If you alter update statement slightly the data gets replicated just fine. The collation on both databases is the same. So far we've only detected the problem with text/varchar fields. (The notes field above is text). Only one or two records in a table are impacted. The table structure looks identical in both 2000/2008. We haven't made any changes. We have found one solution that fixes the problem. Basically if we recreate the table in 2008 (say as MedStaffProvider2) and then insert all the data. Drop the original table. Rename the table to it's original name. Setup replication again. And run the exact same update statement it works as expected. Does anyone have any idea what might be happening here? Or are there any other techniques we can use to troubleshoot this? I've found a solution for this, but would really like to undertsand why this is happening.

    Read the article

  • Windows CE Chat Transcript (March 30, 2010)

    - by Bruce Eitman
    For those of you who missed the chat today, here is the raw transcript.   By raw, I mean that I copied and pasted the discussion without any edits. This is divided into two parts, the top part is the answers from the Microsoft Experts and the bottom part is the questions from the audience. Answers from Microsoft:   Karel Danihelka [MS] (Expert)[2010-3-30 12:2]: Hi everyone, my name is Karel Danihelka and I am developer in partner response team. Sing Wee [MS] (Expert)[2010-3-30 12:2]: Hi, I'm Sing Wee, part of the CoreOS/BSP Test Team. GLanger_MS (Expert)[2010-3-30 12:2]: Hi, I'm Glen Langer, program manager on the Core Team. Karel Danihelka [MS] (Expert)[2010-3-30 12:3]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? A: Until you are using CPU with GHz frequency your only chance is use interrupt handler and implement all funcionality there. But it will be really tricky and may reduce system performance. If period will be near to millisecond timeframe you can use normal thread wait for event pattern. Karel Danihelka [MS] (Expert)[2010-3-30 12:5]: Q: I want to partition my NAND Flash device. One partition to use for hive ragistry and the other for the apps and data. The only way to do it is programmatically or setting some registry values ? A: It need to be set in registry - generally you need mark this partition as boot partition. Karel Danihelka [MS] (Expert)[2010-3-30 12:7]: Q: My CPU is Intel celeron M processor 1Ghz. A: In this case you can try use normal approach - in interrupt handler return SYSINTR and start thread in device driver which will spin thread waiting on event attached to this SYSINTR. Karel Danihelka [MS] (Expert)[2010-3-30 12:7]: Q: If i need to implement it using interrupt handlers, What are all the files that I should look at? A: Good quesiton - I would recommend documentation and there was BSP development book to download for free. mikehall_ms (Moderator)[2010-3-30 12:8]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? A: Using product support is the formal way to report bugs/issues - Product support can then create an issue that can be tracked. Karel Danihelka [MS] (Expert)[2010-3-30 12:9]: Q: But the operation for creating the partitions ? A: This is tricky - if you will make it autopartition & autoformat it will be created by filesystem. But generally it depends on your boot loader. mikehall_ms (Moderator)[2010-3-30 12:10]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: At MIX 2010 Charlie Kindel presented a session that described some of the core technologies that make up Windows Phone 7 Series, including the underlying operating system (Windows CE) and the new ISV programming model based on Silverlight and .NET - check out the Mix Online Videos to get more information. davbo-msft (Moderator)[2010-3-30 12:10]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: This forum is to discussed released products in the industry. Windows Mobile & Windows CE are based on the same Windows CE Kernel/system. Windows CE is focused on deliverying the OS for embedded customers in the market where Windows Mobile is focused on deliverying compelling Windows Phone platform. davbo-msft (Moderator)[2010-3-30 12:11]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: http://en.wikipedia.org/wiki/Windows_CE Wikipedia gives a good breakdown of the version history. Travis Hobrla [MS] (Expert)[2010-3-30 12:13]: Q: I created a OS design with KITL and kernel debugger enabled. But I am unable to connect to the target for debugging. I am getting the following error when i try to connect with the device. PB Debugger Cannot initialize the Kernel Debugger. PB Debugger Debugger could not initialize connection. PB Debugger The Kernel Debugger is waiting to connect with target. PB Debugger The Kernel Debugger has been disconnected successfully. A: One possibility is that a rogue cesvchost.exe has co-opted the debugger. I am assuming this is CE 6.0? Can you try exiting visual studio and manually killing the cesvchost.exe process from the Task Manager? davbo-msft (Moderator)[2010-3-30 12:14]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? A: For info on contacting Microsoft support refer to the support page on the Embedded website: http://msdn.microsoft.com/en-us/windowsembedded/dd897633.aspx Sing Wee [MS] (Expert)[2010-3-30 12:16]: Q: Do u mean ISR/IST implementation? How can i register an interrupt? What kind of interrupt should i register? A: A good introduction to interrupts in WinCE 6.0 can be found here (aside from the documentation on MSDN): http://download.microsoft.com/download/9/c/f/9cffaa58-4000-48d6-a4b2-5fed9e4e6410/Chapter%206%20-%20Developing%20Device%20Drivers.pdf mikehall_ms (Moderator)[2010-3-30 12:16]: Q: What will be different in Windows Compact 7 from CE 6.0? A: Unfortunately we cannot discuss unreleased products on this chat - keep an eye on the Windows Embedded web site and blogs to keep up to date with product announcements. Travis Hobrla [MS] (Expert)[2010-3-30 12:16]: Q: I am using CE 6.0. There is no cesvchost process running in my system. A: What operating system are you using? Karel Danihelka [MS] (Expert)[2010-3-30 12:16]: Q: So...I have to modify file system code to create 2 partition at system startup ?!! I haven't understood.... A: You don't need to modify code, there are registry settings to achive this (look to documentation). But you may need to create partition table in boot loader. Unfortunatelly there isn't simple way how to do it. davbo-msft (Moderator)[2010-3-30 12:18]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Windows Embedded CE 6.0 R3 includes Sliverlight for Windows Embedded. Refer to New Features overview on the embedded web site. http://www.microsoft.com/windowsembedded/en-us/products/windowsce/default.mspx. Silverlight - The power of Silverlight brought to Windows Embedded CE to create rich applications and user interfaces is new part of Windows CE Embedded. mikehall_ms (Moderator)[2010-3-30 12:20]: Q: The link for developing device drivers is not working. can u please check that? A: http://msdn.microsoft.com/en-us/library/ms923714.aspx davbo-msft (Moderator)[2010-3-30 12:20]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Sorry misunderstood the question I thought you were asking if embedded CE could handle Silverlight. Please repost so that the question goes back into the active queue because once answered no way to put the status back to open. Travis Hobrla [MS] (Expert)[2010-3-30 12:21]: Q: sorry! Windows XP SP3 A: Can you try exiting VS2005 and confirming cesvchost.exe is not running, then renaming C:\Documents and Settings\USERNAME\Local Settings\Application Data\Microsoft\CoreCon\1.0 to 1.0_backup, then restarting VS2005? Sing Wee [MS] (Expert)[2010-3-30 12:24]: Q: Can I have the book's name please? A: I believe the downloadable version is related to the last link I sent. If you go to the following website, I believe you can download the whole thing: http://msdn.microsoft.com/en-us/windowsembedded/ce/cc294468.aspx davbo-msft (Moderator)[2010-3-30 12:24]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? A: change the URI of the image or use a writeable bitmap if they want to manually toggle the pixels Sing Wee [MS] (Expert)[2010-3-30 12:25]: A: Whoops, hit [ENTER] too early. On the right side, you'll see there an "Exam Preparation Kit" link that can be downloaded in several different languages. Sing Wee [MS] (Expert)[2010-3-30 12:25]: Q: Can I have the book's name please? A: Whoops, hit [ENTER] too early. On the right side, you'll see there an "Exam Preparation Kit" link that can be downloaded in several different languages. Karel Danihelka [MS] (Expert)[2010-3-30 12:26]: Q: I have a NAND Flash on my target device. On this flash I have the hive registry and an application.I have observed that when the NAND flash is fully, the system startup time is longer....is there a degradation of NAND use that influences the startup time ? Why ? A: Yes - on boot flash abstraction library (old one) read metadata from all sectors to rebuild physical - logical mapping table. davbo-msft (Moderator)[2010-3-30 12:27]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Need addition info on this question. Can you provide more details on what you are trying to do in Silverlight? davbo-msft (Moderator)[2010-3-30 12:27]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? A: Additonal Info: if you want to manually touch the pixels use WriteableBitmap if you want to use the underlying HWND then use IXRVisualHost::GetHWND() davbo-msft (Moderator)[2010-3-30 12:28]: Q: Writable bitmap, is there an example of the syntax? A: if you want to manually touch the pixels use WriteableBitmap if you want to use the underlying HWND then use IXRVisualHost::GetHWND() davbo-msft (Moderator)[2010-3-30 12:29]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Can I get more information about this question about what you are trying to accomplish in Silverlight? davbo-msft (Moderator)[2010-3-30 12:31]: Q: IXRVisualHost::GetHWND() exactly what I needed Thanks, A: Your welcome Sing Wee [MS] (Expert)[2010-3-30 12:31]: Q: ok. thanks for the book's link A: No problem. Travis Hobrla [MS] (Expert)[2010-3-30 12:32]: Q: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. A: There are a couple workarounds I can think of. I believe the Module element is only used when doing SYSGEN parsing to make sure dependent SYSGENs are present when the item is selected, so I believe it is optional to the catalog. The other obvious workaround is to shorten the soc name. I realize neither of these solutions is ideal. This is not something we anticipated when we tested CE6.0, sorry. Travis Hobrla [MS] (Expert)[2010-3-30 12:33]: Q: I am getting this error only when I select the KdStub as the debugger in Target device connectivity. A: Right, but KdStub is the debugger that you should use. Have you tried the steps I suggested? Travis Hobrla [MS] (Expert)[2010-3-30 12:36]: Q: If I select Active KTIL, My OS doesn't boots. It says "loading NK.EXE at 0x<xxxxx> location" after that nothing comes in the debug log. A: Can you look at the serial debug output and see what is happening there? Often it can give you a clue to the KITL driver malfunctioning. Travis Hobrla [MS] (Expert)[2010-3-30 12:38]: Q: I have tried that and I am getting the same error. A: I am assuming you have a device created in Target -> Connectivity Options in Platform Builder. What are the Kernel download / Kernel transport for your device? Travis Hobrla [MS] (Expert)[2010-3-30 12:40]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug A: This looks reasonable and does not give clues as to why boot would halt at that point. If you capture a network trace or turn on KITL debug zones via dpCurSettings in kitl.dll, do you see KITL active after this? Travis Hobrla [MS] (Expert)[2010-3-30 12:41]: Q: Both is happening via Ethernet. A: Only thing I have left to suggest is a Platform Builder installation Repair, then. Karel Danihelka [MS] (Expert)[2010-3-30 12:42]: Q: Hi, I saw that the ATADISK is quite generic and des not have any optimizations. Do you have any advice to consider while tryin to improve the performance of it? A: If I remember correctly sample code has support for some specific hardware controllers (little obsolete now). This should be good start point (if you will not decide take existing driver as sample and write you own). Travis Hobrla [MS] (Expert)[2010-3-30 12:44]: Q: I didn't do that. I have to try. A: I think that's the next valid step. You need to figure out whether KITL is hanging or the device - use instrumented serial debug messages and network trace to determine this. Sing Wee [MS] (Expert)[2010-3-30 12:46]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug A: Neo, have you by any chance tried looking into your firewall to see if it might be blocking traffic on any particular ports? Wireshark/netmon might be able to help you here if that's the issue. davbo-msft (Moderator)[2010-3-30 12:48]: Q: I lost spell check, how can i get it back A: Hello - can you give additional details about your question? Is this related to a Windows CE Embedded application? masatos_MSFT (Expert)[2010-3-30 12:51]: Q: When attempting to run the CETK cellcore tests the documentation states the pre-requisites include "stinger.ini", "ltk.ini" but windows CE doesn't provide these or document what they fully need to contain. Implicitly you also need "datatrans.xml" which isn't supplied. If you get around this error and steal these from Windows Mobile instead, when you try and run the CETK tests you get a data abort in radiometricsdll.dll. How should we invoke the cellcore parts of CETK? A: Hi Pev, what version of Windows CE and CETK are you using? I do not have the expertise to answer this question, but can find somebody who can. Travis Hobrla [MS] (Expert)[2010-3-30 12:52]: Q: I don't see a kitlcore.dll in my OS. is my debug image fails to load because of that? A: kitl.dll should be all that's needed, kitlcore.lib is linked into that. Travis Hobrla [MS] (Expert)[2010-3-30 12:55]: Q: I've got a platform (not developed by myself) where I2C bus support has to be provided through the OAL as the kernel needs to talk to devices such as the power management IC and gas gauge so a 'proper' I2C driver hanging off device manager isn't possible. This happens to be a polled driver, so obviously it hits the system hard when either under lots of traffic or an error condition occurs and the driver constantly polls. I originally thought that there was no straightforward way to make such code interrupt driven in the kernel (as it's a cludge) but I realised that that's exactly what ETHDBG drivers do. Is there any reason why I shouldn't have a go at implementing a similar mechanism for our kernel resident I2C driver? If not, are there any obvious pitfalls - I've not seen any other BSP's do this in the past... A: You can make a 'proper' driver that calls down into the OAL to do the actual I2C transactions. Alternatively you can build an interrupt-based version in the OAL where you handle everything in the ISR. There is nothing wrong with that so long as the rest of your drivers and app threads can handle longer times with interrupts off while you are servicing I2C interrupts. Sing Wee [MS] (Expert)[2010-3-30 12:55]: Q: I am having trouble with my mouse, I have the microsoft wireless mobile mouse 3000, when I push the scroll button I am suppose to have autoscroll instead it shows other web pages,Can you help me out tell me what to do!!! A: Sorry, this current chat is about Windows Embedded Compact. Hope you're able to find an answer to your question elsewhere. davbo-msft (Moderator)[2010-3-30 12:56]: Q: Is the Silverlight Animation "Spline" a BezierSpline? A: Spline - http://msdn.microsoft.com/en-us/library/ee501495.aspx<BR< a>>   masatos_MSFT (Expert)[2010-3-30 12:57]: Thanks for the info Pev. I will follow up with the CETK experts here and get back to you. davbo-msft (Moderator)[2010-3-30 12:59]: Q: Spline- bad link A: http://msdn.microsoft.com/en-us/library/ee501495.aspx davbo-msft (Moderator)[2010-3-30 13:0]: Q: Sorry, got to tirm the ">" A: No Worries http://msdn.microsoft.com/en-us/library/ee501495.aspx davbo-msft (Moderator)[2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; davbo-msft (Moderator)[2010-3-30 13:1]: Q: hi everybody. I would like to know if there is something know about a bug in RTC API (VOIP), especially when using SIP. According the to the analysis with application verifyier there is a heap link in rtcdllmedia.dll. All of the unreleased chunks seem to have a size of 6560 bytes. A: I will follow up with the Networking Team for a response. davbo-msft (Moderator)[2010-3-30 13:1]: Q: Hi, we've problems with debugging of applications (= breakpoints in Platform Builder will be ignored) over KITL on Windows CE 5.0, if the PDB files are large (over 60MB). Are there any limitations to size of the PDB files? A: I will follow up with the tools team for a response and post with the transcript. Sing Wee [MS] (Expert)[2010-3-30 13:1]: Q: I am unable to use the target control in my development environment. any ideas? A: Make sure you have SYSGEN_SHELL=1 set in your build environment. davbo-msft (Moderator)[2010-3-30 13:3]: Q: what are the main differences between Object Store and RAM disk ? They are both in RAM...are there performance differences ? access differences ? A: I will follow up with the Core Team and get a response posted with the transcript to MSDN  The Questions   [2010-3-30 12:57]: Thanks for the info Pev. I will follow up with the CETK experts here and get back to you. [2010-3-30 12:59]:   [2010-3-30 13:0]:   [2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; [2010-3-30 13:1]: [2010-3-30 13:1]: [2010-3-30 13:1]: [2010-3-30 13:3]: neo (Guest)[2010-3-30 11:37]: Hi all KellyG (Guest)[2010-3-30 11:37]: Hi KellyG (Guest)[2010-3-30 11:37]: I have a question unrelated to windows Ce embedded, can you please help me?? neo (Guest)[2010-3-30 11:38]: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals! c neo (Guest)[2010-3-30 11:38]: yes. post it. May be i cud give a try KellyG (Guest)[2010-3-30 11:38]: My Product key listed on my tower is not the product key I need for microsoft office, but that is the only product key listed. neo (Guest)[2010-3-30 11:39]: I hope this is a chat for windows embedded. please post ur queries in office forums KellyG (Guest)[2010-3-30 11:39]: it is but i could not find a forum for office neo (Guest)[2010-3-30 11:40]: I think moderators will help u out. @ davbo-msft: can u help this guy? neo (Guest)[2010-3-30 11:41]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? davbo-msft (Moderator)[2010-3-30 11:50]: Our chat today covers the topic of Windows Embedded CE! 1. This chat will last for one hour. During this hour, our Experts will respond to as many questions as they can. Please understand that there may be some questions we cannot respond to due to lack of information or because the information is not yet public. 2. We encourage you to submit questions for our Experts. To do so, type your questions in the send box, select the “ask the Experts” box and click SEND. Questions sent directly to the Guest Chat room will not be answered by the Experts, but we encourage other community members to assist. 3. We ask that you stay on topic for the duration of the chat. This helps the Guests and Experts follow the conversation more easily. We invite you to ask off topic questions after this chat is over, but not during. 4. Please abide by the Chat Code of Conduct. Chat code of conduct: <http://msdn.microsoft.com/chats/chatroom.aspx?ctl=hlp#Conduct>; Pev (Guest)[2010-3-30 11:54]: Evening! davbo-msft (Moderator)[2010-3-30 11:54]: Hello everyone this is Dave Boyce - I worked in the Multimedia area for Windows CE. neo (Guest)[2010-3-30 11:55]: hello dave neo (Guest)[2010-3-30 11:55]: The chat code of conduct link is not working! Pev (Guest)[2010-3-30 11:56]: Best be polite just in case then ;-) neo (Guest)[2010-3-30 11:56]: davbo-msft (Moderator)[2010-3-30 11:57]: I'll check out the issue w/ the link paolopat (Guest)[2010-3-30 12:0]: Hello davbo-msft (Moderator)[2010-3-30 12:0]: We are pleased to welcome our Experts for today’s chat. I will have them introduce themselves now. Chat will begin in a couple of minutes. <http://www.Microsoft.com/Embedded>; paolopat (Guest)[2010-3-30 12:3]: Hello Experts ! neo (Guest)[2010-3-30 12:3]: Welcome all! paolopat (Guest)[2010-3-30 12:3]: Q: I want to partition my NAND Flash device. One partition to use for hive ragistry and the other for the apps and data. The only way to do it is programmatically or setting some registry values ? neo (Guest)[2010-3-30 12:3]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? neo (Guest)[2010-3-30 12:5]: Q: My CPU is Intel celeron M processor 1Ghz. Pev (Guest)[2010-3-30 12:5]: neo: if your silicon has multiple general purpose timers, pick one that's not in use for the system timer / profiler and set it up to trigger irqs for your purpose. You can't guarantee hard realtime type responses though... GarySwalling (Guest)[2010-3-30 12:5]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? Pev (Guest)[2010-3-30 12:6]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? paolopat (Guest)[2010-3-30 12:6]: Q: But the operation for creating the partitions ? neo (Guest)[2010-3-30 12:6]: Q: If i need to implement it using interrupt handlers, What are all the files that I should look at? GPM (Guest)[2010-3-30 12:6]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? Jhony (Guest)[2010-3-30 12:7]: Q: I created a OS design with KITL and kernel debugger enabled. But I am unable to connect to the target for debugging. I am getting the following error when i try to connect with the device. PB Debugger Cannot initialize the Kernel Debugger. PB Debugger Debugger could not initialize connection. PB Debugger The Kernel Debugger is waiting to connect with target. PB Debugger The Kernel Debugger has been disconnected successfully. Charles (Guest)[2010-3-30 12:7]: What will be different in Windows Compact 7 from CE 6.0? neo (Guest)[2010-3-30 12:8]: Can I have the book's name please? kiefs_dev (Guest)[2010-3-30 12:8]: Q: hi everybody. I would like to know if there is something know about a bug in RTC API (VOIP), especially when using SIP. According the to the analysis with application verifyier there is a heap link in rtcdllmedia.dll. All of the unreleased chunks seem to have a size of 6560 bytes. paolopat (Guest)[2010-3-30 12:10]: Q: So...I have to modify file system code to create 2 partition at system startup ?!! I haven't understood.... neo (Guest)[2010-3-30 12:10]: Q: Do u mean ISR/IST implementation? How can i register an interrupt? What kind of interrupt should i register? neo (Guest)[2010-3-30 12:11]: Q: Can I have the book's name please? Charles (Guest)[2010-3-30 12:11]: Q: What will be different in Windows Compact 7 from CE 6.0? PaulT (Guest)[2010-3-30 12:11]: neo: I'd say that you really need the docs for YOUR BSP, not generic documents for BSPs in general. Each BSP may be architected differently. If you're using the CEPC BSP, then the documentation that comes with Platform Builder is a reasonable place to look. GPM (Guest)[2010-3-30 12:11]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? Elektrobit (Guest)[2010-3-30 12:12]: Q: Hi, we've problems with debugging of applications (= breakpoints in Platform Builder will be ignored) over KITL on Windows CE 5.0, if the PDB files are large (over 60MB). Are there any limitations to size of the PDB files? Jhony (Guest)[2010-3-30 12:15]: Q: I am using CE 6.0. There is no cesvchost process running in my system. alexquisi (Guest)[2010-3-30 12:15]: Q: Hi, I saw that the ATADISK is quite generic and des not have any optimizations. Do you have any advice to consider while tryin to improve the performance of it? Jhony (Guest)[2010-3-30 12:17]: Windows XP service pack 1 Jhony (Guest)[2010-3-30 12:17]: Q: sorry! Windows XP SP3 neo (Guest)[2010-3-30 12:19]: Q: The link for developing device drivers is not working. can u please check that? paolopat (Guest)[2010-3-30 12:20]: Q: I have a NAND Flash on my target device. On this flash I have the hive registry and an application.I have observed that when the NAND flash is fully, the system startup time is longer....is there a degradation of NAND use that influences the startup time ? Why ? Pev (Guest)[2010-3-30 12:20]: Q: When attempting to run the CETK cellcore tests the documentation states the pre-requisites include "stinger.ini", "ltk.ini" but windows CE doesn't provide these or document what they fully need to contain. Implicitly you also need "datatrans.xml" which isn't supplied. If you get around this error and steal these from Windows Mobile instead, when you try and run the CETK tests you get a data abort in radiometricsdll.dll. How should we invoke the cellcore parts of CETK? Pev (Guest)[2010-3-30 12:21]: Hi all, Pev (Guest)[2010-3-30 12:21]: oops Pev (Guest)[2010-3-30 12:21]: :-D Pev (Guest)[2010-3-30 12:24]: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Pev (Guest)[2010-3-30 12:25]: Q: Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. GPM (Guest)[2010-3-30 12:25]: Q: Writable bitmap, is there an example of the syntax? Pev (Guest)[2010-3-30 12:25]: Q: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. Pev (Guest)[2010-3-30 12:25]: sorry, messed up submission there! GPM (Guest)[2010-3-30 12:26]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? GPM (Guest)[2010-3-30 12:28]: Q: IXRVisualHost::GetHWND() exactly what I needed Thanks, PaulT (Guest)[2010-3-30 12:29]: GPM: You don't have to keep submitting the questions. The chat experts have an application that they're using to follow the chat and all Ask the Experts questions are logged. Jhony (Guest)[2010-3-30 12:29]: Q: I am getting this error only when I select the KdStub as the debugger in Target device connectivity. neo (Guest)[2010-3-30 12:30]: Q: ok. thanks for the book's link Pev (Guest)[2010-3-30 12:31]: Hm, did those two I submitted get picked up by anyone? neo (Guest)[2010-3-30 12:33]: Q: If I select Active KTIL, My OS doesn't boots. It says "loading NK.EXE at 0x<xxxxx> location" after that nothing comes in the debug log. PaulT (Guest)[2010-3-30 12:34]: Pev: PaulT (Guest)[2010-3-30 12:35]: Pev: I'm sure they did. The guys who are actually on the chat may not be experts in that part of things. That's usually the explanation when you don't get an answer in 10 minutes or so. Pev (Guest)[2010-3-30 12:36]: Ah, fair enough Susie (Guest)[2010-3-30 12:36]: My Outlook Express incoming mail is corrput. No ONE has been able to fix the problem, Dell or Norton. I have dial up I'm in a rural area Jhony (Guest)[2010-3-30 12:37]: Q: I have tried that and I am getting the same error. Pev (Guest)[2010-3-30 12:37]: Susie : Use Thunderbird instead :-D PaulT (Guest)[2010-3-30 12:37]: Susie: Sorry, but this chat is not about Windows, but Embedded (like what runs on a phone). Your best chance is to find a local expert or talk to your ISP. paolopat (Guest)[2010-3-30 12:37]: Q: what are the main differences between Object Store and RAM disk ? They are both in RAM...are there performance differences ? access differences ? Susie (Guest)[2010-3-30 12:38]: My computer knowlege is very limited, what is Thunderbird? Pev (Guest)[2010-3-30 12:38]: A different email client :-D neo (Guest)[2010-3-30 12:39]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug Susie (Guest)[2010-3-30 12:39]: Do I need to uninstall Outlook Express youngboyzie (Guest)[2010-3-30 12:39]: I need to start battery calibration for my new battery for my dell inspiron 1525 laptop and should be able to reach the BIOS screen by hitting f2 but this isnt working... help? Pev (Guest)[2010-3-30 12:39]: Nah, you can run it instead - you'll still need help from your ISP to configure it I expect Jhony (Guest)[2010-3-30 12:39]: Q: Both is happening via Ethernet. PaulT (Guest)[2010-3-30 12:40]: youngboyzie: You're off-topic. This is not a general chat for Windows and certainly not for Dell. You'll have to ask Dell how to get to setup; it's their machine. bill (Guest)[2010-3-30 12:41]: I lost spell check, how can i get et back neo (Guest)[2010-3-30 12:42]: Q: I didn't do that. I have to try. Jhony (Guest)[2010-3-30 12:43]: Q: Ok. I will do it then. bill (Guest)[2010-3-30 12:43]: Q: I lost spell check, how can i get it back PaulT (Guest)[2010-3-30 12:44]: bill: This isn't a general Windows chat. There are some Web forums that you might try. GarySwalling (Guest)[2010-3-30 12:45]: Q: Thanks, I found the Phone 7 presentation at http://live.visitmix.com/MIX10/Sessions/CL13 GPM (Guest)[2010-3-30 12:45]: Q: Is the Silverlight Animation "Spline" a BezierSpline? neo (Guest)[2010-3-30 12:46]: Q: ok. I'll do it. thanks Pev (Guest)[2010-3-30 12:46]: Whowever was asking about KITL connection : I've had this loads in the past. I think I started debugging last time by using wireshark to see what was happening on the network then setting up the OAL_ETHER and OAL_FUNC and OAL_VERBOSE as well as OAL_KITL flags to see what was actually happening in the driver.... Pev (Guest)[2010-3-30 12:47]: I'd generally make sure that you're testing though a 10baseT hub (instead of anything faster) and forcing Active KITL in polled mode too... neo (Guest)[2010-3-30 12:48]: Q: I disabled the firewall in my PC. Pev (Guest)[2010-3-30 12:50]: Q: I've got a platform (not developed by myself) where I2C bus support has to be provided through the OAL as the kernel needs to talk to devices such as the power management IC and gas gauge so a 'proper' I2C driver hanging off device manager isn't possible. This happens to be a polled driver, so obviously it hits the system hard when either under lots of traffic or an error condition occurs and the driver constantly polls. I originally thought that there was no straightforward way to make such code interrupt driven in the kernel (as it's a cludge) but I realised that that's exactly what ETHDBG drivers do. Is there any reason why I shouldn't have a go at implementing a similar mechanism for our kernel resident I2C driver? If not, are there any obvious pitfalls - I've not seen any other BSP's do this in the past... neo (Guest)[2010-3-30 12:51]: Q: I don't see a kitlcore.dll in my OS. is my debug image fails to load because of that? Pev (Guest)[2010-3-30 12:52]: Q: Hi masatos, I'm using Windows Embedded CE 6.0 with R3 and patched to feb 2010's QFE's (with it's associated CETK version) this is a machine with only CE 6.0 on (no conflicts with earlier CE or WM...) neo (Guest)[2010-3-30 12:54]: ok. Got it neo (Guest)[2010-3-30 12:54]: Q: ok. Got it Roundman (Guest)[2010-3-30 12:55]: Q: I am having trouble with my mouse, I have the microsoft wireless mobile mouse 3000, when I push the scroll button I am suppose to have autoscroll instead it shows other web pages,Can you help me out tell me what to do!!! Pev (Guest)[2010-3-30 12:55]: Hey neo, debugging kitl issues is really frustrating but dont lose heart :-) neo (Guest)[2010-3-30 12:55]: @ pev : u fixed the problem of KITL after that? neo (Guest)[2010-3-30 12:56]: I am getting the same error again and again. I even cleaned my environment and tried in a fresh PC. But didn't succeed yet Pev (Guest)[2010-3-30 12:56]: Well, eventually - my experiences probably won't help you as different platforms have different reasons for doing that neo (Guest)[2010-3-30 12:56]: I think so PaulT (Guest)[2010-3-30 12:58]: neo: Have you searched the old messages in microsoft.public.windowsce.platbuilder? It seems to me that there was a packet size situation where it was possible to have problems with KITL connections based on a setting on the PC. Google Groups, groups.google.com, Advanced Groups Search will allow you to search a single newsgroup or a set of newsgroups easily. GPM (Guest)[2010-3-30 12:58]: Q: Spline- bad link PaulT (Guest)[2010-3-30 12:58]: GPM: without the > at the end does it work? It seems to for me... neo (Guest)[2010-3-30 12:58]: But some times if i try to connect to the device again. The Image information is seen in the serial debug. what does that mean?Download BIN file information: ----------------------------------------------------- [0]: Base Address=0x220000 Length=0x18DAADC Received a broadcast message !CheckUDP: Not UDP (proto = 0x00000001) after this i am getting the old errors. PB debugger cannot initialize ... GPM (Guest)[2010-3-30 12:59]: Q: Sorry, got to tirm the ">" neo (Guest)[2010-3-30 12:59]: ok paul. I ll look into that. davbo-msft (Moderator)[2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; neo (Guest)[2010-3-30 13:1]: Q: I am unable to use the target control in my development environment. any ideas? Pev (Guest)[2010-3-30 13:1]: Sure, if KITL isn't connected target control won't work as it runs over kitl... neo (Guest)[2010-3-30 13:1]: ok .thanks pev neo (Guest)[2010-3-30 13:2]: yes. sysgen_shell is set to 1 neo (Guest)[2010-3-30 13:2]: Q: yes. sysgen_shell is set to 1 Marcelovk (Guest)[2010-3-30 13:2]: Q: Is there any way to extract the default command lines of the tests in CETK? I want to have it running unconnected from the desktop.   Copyright © 2010 – Bruce Eitman All Rights Reserved

    Read the article

  • Uninstalling Reporting Server 2008 on Windows Server 2008

    - by Piotr Rodak
    Ha. I had quite disputable pleasure of installing and reinstalling and reinstalling and reinstalling – I think about 5 times before it worked – Reporting Server 2008 on Windows Server with the same year number in name. During my struggle I came across an error which seems to be not quite unfamiliar to some more unfortunate developers and admins who happen to uninstall SSRS 2008 from the server. I had the SSRS 2008 installed as named instance, SQL2008. I wanted to uninstall the server and install it to default instance. And this is when it bit me – not the first time and not the last that day . The setup complained that it couldn’t access a DLL: Error message: TITLE: Microsoft SQL Server 2008 Setup ------------------------------ The following error has occurred: Access to the path 'C:\Windows\SysWOW64\perf-ReportServer$SQL2008-rsctr.dll' is denied. For help, click: http://go.microsoft.com/fwlink?LinkID=20476&ProdName=Microsoft+SQL+Server&EvtSrc=setup.rll&EvtID=50000&ProdVer=10.0.1600.22&EvtType=0x60797DC7%25400x84E8D3C0 ------------------------------ BUTTONS: OK This is a screenshot that shows the above error: This issue seems to have a bit of literature dedicated to it and even seemingly a KB article http://support.microsoft.com/kb/956173 and a similar Connect item: http://connect.microsoft.com/SQLServer/feedback/details/363653/error-messages-when-upgrading-from-sql-2008-rc0-to-rtm The article describes issue as following: When you try to uninstall Microsoft SQL Server 2008 Reporting Services from the server, you may receive the following error message: An error has occurred: Access to the path 'Drive_Letter:\WINDOWS\system32\perf-ReportServer-rsctr.dll' is denied. Note Drive_Letter refers to the disc drive into which the SQL Server installation media is inserted. In my case, the Note was not true; the error pointed to a dll that was located in Windows folder on C:\, not where the installation media were. Despite this difference I tried to identify any processes that might be keeping lock on the dll. I downloaded Sysinternals process explorer and ran it to find any processes I could stop. Unfortunately, there was no such process. I tried to rerun the installation, but it failed at the same step. Eventually I decided to remove the dll before the setup was executed. I changed name of the dll to be able to restore it in case of some issues. Interestingly, Windows let me do it, which means that indeed, it was not locked by any process. I ran the setup and this time it uninstalled the instance without any problems:   To summarize my experience I should say – be very careful, don’t leave any leftovers after uninstallation – remove/rename any folders that are left after setup has finished. For some reason, setup doesn’t remove folders and certain files. Installation on Windows Server 2008 requires more attention than on Windows 2003 because of the changed security model, some actions can be executed only by administrator in elevated execution mode. In general, you have to get used to UAC and a bit different experience than with Windows Server 2003. Technorati Tags: SQL Server 2008,Windows Server 2008,SRS,Reporting Services

    Read the article

  • SQL Server v.Next (Denali) : Another SSMS bug that should be fixed

    - by AaronBertrand
    Sorry to call this out in a separate post (I talked about a bunch of SSMS Connect items the other day), but Aaron Nelson ( blog | twitter ) jogged my memory today about an issue that has gone unfixed for years: the custom coloring for Registered Servers is neither consistent nor global. For one of my servers, I've chosen a red color to show in the status bar. Let's pretend this is a production server, and I want the red to remind me to use caution. I can set this up by right-clicking a Registered...(read more)

    Read the article

  • Windows Server 2003 Terminal Server does not give out all available licenses

    - by Erwin Blonk
    I installed the Terminal Server role in Windows Server 2003 Standard 64-bits. Still, only 2 connections are allowed. The License Manager says that there are 10 Device CALs available, which is correct, and that none are given out. For good measure I let the server reboot, to no effect. Before this, there was another server (same Windows, except that it is 32 bits) active as a licensing server. I removed the role first and then then added it to the new server. I then removed the Terminal Server Licensing Server component off the old one and added it to the new one. After that, I added to licenses. When that didn't give the required result, I rebooted to new server. Still, the new server, with licenses and all, acts as if it has the 2 license RDP. The server are all stand-alone, there is no active directory been set up. Both servers are in different workgroups. Update (4/12/10): The server has changed the entries in the Terminal Server Licensing a few times. After installing the licenses it added an entry of which the exact phrasing I forgot but it was about temporary Windows 2003 device licenses. Later it added Windows Server 2003 - TS Per Device CAL. The temporary held 2 licenses (standard RDP licenses, I think) and the other 10. At some point, seemingly unrelated from the testing we did, it used a licenses from the new pool. This morning, 2 licenses were used from the pool of 10 and only 1 from the temporary/RDP pool (I wish I had screenshots to show, it changed every few hours oir so it seems). Although I had already activated the server over the internet, and re-activated it, I decided to go through the whole procedure by phone. Long story short, here is what it says now: Existing Windows 2000 Server, type:built-in [no licenses used, I add for for sake of being complete] Windows Server 2003 - Terminal Server Per Device CAL Token, type:open [none of 10 used] Windows Server 2003 - TS Per Device CAL, type:open [3 of 10 used] As I tried to explain, this is the end result after a few changes, most of which I can't directly connect to any action from my part. Only going to the activation procedure by phone seemed to directly effect the TS, resulting in the above configuration. Still, it is impossible to connect with more than 3 people, which is 1 up from the 2 that could connect yesterday. TS does say 7 licenses are avaible. Yet it won't give them out.

    Read the article

  • SQL Compact import DB from SQL Server Express with Server Management Studio

    - by Sasha
    Hi! I try to import sql script, generated with Server Management Studio, into SQL Compact 3.5 and get a lot of error. What I am doing wrong? I generate script with "Task/Generate Script" context menu. Part of my script: CREATE TABLE [LogMagazines]( [IdUser] [int] NOT NULL, [Text] [nvarchar](500) NULL, [TypeLog] [int] NOT NULL, [DateAndTime] [datetime] NOT NULL, [DetailMessage] [nvarchar](max) NULL, [Id] [int] IDENTITY(1,1) NOT NULL, CONSTRAINT [PK_LogMagazines] PRIMARY KEY ( [Id] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] Knowledge Base: http://stackoverflow.com/questions/1525063/how-to-import-data-in-sql-compact-edition http://stackoverflow.com/questions/1515969/exporting-data-in-sql-server-as-insert-into/1515975

    Read the article

< Previous Page | 31 32 33 34 35 36 37 38 39 40 41 42  | Next Page >