Search Results

Search found 29554 results on 1183 pages for 'human computer interface'.

Page 350/1183 | < Previous Page | 346 347 348 349 350 351 352 353 354 355 356 357  | Next Page >

  • XML documentation to context sensitive help

    - by Yonas
    These days a number of commercial and open source tools have been developed for this purpose. However(unfortunately), non of them meet my requirement for specific problem I am dealing with. Currently, I am working on a project that exposes a different classes and functions to user as scripting interface. the user can use the objects from custom scripting interface and call methods to solve some specific problem. The problem I am facing is users of my classes need some sort of documentation in order to write their script efficiently. To address this problem am planing to use the compiler generated XML file to provide context sensitive help, which allows users to mouse over on any of the controls and corresponding methods from the GUI and read the reference documentation of the class/method. Now ... here are my questions: Can I get the sample source code? Can any one give me someone point me to some sort of best approach to address the problem?

    Read the article

  • "this device cannot start error code 10" ?

    - by Neo
    I am trying to install GPS driver for gmm-u1lp.I think which is just a virtual com port driver. It just contains following INF file: [Version] Signature="$Windows NT$" Class=Ports ClassGuid={4D36E978-E325-11CE-BFC1-08002BE10318} Provider=%MTK% ;LayoutFile=layout.inf DriverVer=06/12/2007,1.0.0.1 [Manufacturer] %MTK%=MTK [MTK] %MTK3329%=Reader,USB\Vid_0e8d&Pid_3329 [Reader_Install.NTx86] ;Windows2000 [DestinationDirs] DefaultDestDir=12 Reader.NT.Copy=12 [Reader.NT] Include=mdmcpq.inf CopyFiles=FakeModemCopyFileSection AddReg=Reader.NT.AddReg [Reader.NT.AddReg] HKR,,DevLoader,,*ntkern HKR,,NTMPDriver,,usbser.sys HKR,,EnumPropPages32,,"MsPorts.dll,SerialPortPropPageProvider" [Reader.NT.Services] AddService = usbser, 0x00000002, Service_Inst [Service_Inst] DisplayName = %Serial.SvcDesc% ServiceType = 1 ; SERVICE_KERNEL_DRIVER StartType = 3 ; SERVICE_DEMAND_START ErrorControl = 1 ; SERVICE_ERROR_NORMAL ServiceBinary = %12%\usbser.sys LoadOrderGroup = Base [Strings] MTK = "Media Tek Inc." MTK3329 = "GPS USB Serial Interface Driver" Serial.SvcDesc = "GPS USB Serial Interface Driver" After installing this Inf,device details shows:"device cannot start error code 10". What is the exact problem? Do I need to test this after connecting the Device?

    Read the article

  • Identify which AlertDialog triggered onClick(DialogInterface dialog, int which)

    - by Kurian
    I'm creating a dialog as follows: @Override protected Dialog onCreateDialog(int id) { switch (id) { case DIALOG_1: return new AlertDialog.Builder(this) .setTitle(R.string.s_dlg1) .setPositiveButton(android.R.string.ok, this) .create(); case DIALOG_2: ... ... } return null; } @Override public void onClick(DialogInterface dialog, int whichButton) { if (dialog == ???) { ... } else if (dialog == ???){ ... } } How do I identify which dialog triggered the onClick method? I can't declare the interface methods as in-line when creating the dialog because I want to access variables in my class. Every other interface passes some sort of id to its methods to identify which object called the method, but I can't seem to do anything with 'DialogInterface dialog'.

    Read the article

  • edited an .SWF, locally the changes made are okay, but when on server changes are not fully visible

    - by Andy
    Hi, I just edited an .SWF file I have on my website home page for a while now. I update the SWF frequently with new pictures. It's actually a picture slideshow, consisting out of 6 images. I used Adobe Flash CS4 Pro to edit the file, with just swapping all the pictures (JPGS) in it for other ones. I also have some small AS where I just have the URL: on(release) { getURL("link"); } so that's nothing fancy at all. I saved and published everything (CTRL+ENTER) and the .SWF played well, and tested it in IE8 and FF. Then I uploaded the SWF to my test server, overwriting the existing SWF file. Now the problem: all pictures but one show up well. Of the 6 images, the second image is actually the old image that was in its place. I downloaded the .SWF from the testserver and inspected the SWF and guess what: the old picture wasn't in it, instead the correct image was in the SWF. Even after reloading the page hitting CTRL+F5 still the wrong image shows. FF though shows the SWF correctly. So I then opened the page on another computer using IE8 and there the SWF works well, showing the correct second image. What's wrong with my first computer's browser? It's also the computer I edited the SWF with. I DO remember like I first saved and uploaded the wrong SWF (with the old 2nd image still in it) to the testserver, and later on uploading the correct one (proper 2nd image) I think IE8 has cached the wrong SWF, and now memorized it someway not willing to see that the file has actually been changed, but what to do so IE8 starts showing the correct SWF??

    Read the article

  • MTU mismatch between GetIfEntry and netsh

    - by ChrisJ
    I'm working on pseudo-transport layer software that runs over UDP, providing reliable connection-oriented transmission, as an alternative to TCP. In order to maximize network efficiency, we query the MTU of the "best" network adapter upon initialization. MIB_IFROW row = {0}; row.dwIndex = dwBestIfIndex; dwRes = GetIfEntry(&row); Searching online I found that you can use the following netsh commands to query for this same value, from a command prompt (not a C++ API) netsh interface ipv4 show interfaces netsh interface ipv4 show subinterfaces The troubling issue is that while row.dwMtu may be set to 1500, snooping the network traffic on the sending laptop shows that our packets are fragmented into 1300 byte packets. netsh also reports that the MTU is 1300. Clearly the value reported by netsh command is the actual used values. Anyone know what API I can call to get the same values as netsh?

    Read the article

  • How to check if a generic type definition inherits from another generic type definition

    - by Anne
    I'm trying to check whether an open generic type definition implements some open generic interface. Look at the sample below: public interface IService<T> { } public class ServiceImpl<T> : IService<T> { } private static bool OpenGenericTypeImplementsOpenGenericInterface( Type derivedType, Type interfaceType) { return derivedType.GetInterfaces().Contains(interfaceType); } [TestMethod] public void Verify() { Type openGenericImplementation = typeof(ServiceImpl<>); Type expectedInterfaceType = typeof(IService<>); bool implDoesImplementInterface = OpenGenericTypeImplementsOpenGenericInterface( openGenericImplementation, expectedInterfaceType); // This assert fails. Why? Assert.IsTrue(implDoesImplementInterface); } I found out that the returned type from the Type.GetInterfaces() method does not match the type returned from typeof(IService<>). I can't figure out why that is and how to correctly validate whether some generic type definition inherits or implements some other generic type definition. What's going on here and how do I solve fix this problem?

    Read the article

  • Why are getters prefixed with the word "get"?

    - by Joey
    Generally speaking, creating a fluid API is something that makes all programmers happy; Both for the creators who write the interface, and the consumers who program against it. Looking beyond conventions, why is it that we prefix all our getters with the word "get". Omitting it usually results in a more fluid, easy to read set of instructions, which ultimately leads to happiness (however small or passive). Consider this very simple example. (pseudo code) Conventional: person = new Person("Joey") person.getName().toLower().print() Alternative: person = new Person("Joey") person.name().toLower().print() Of course this only applies to languages where getters/setters are the norm, but is not directed at any specific language. Were these conventions developed around technical limitations (disambiguation), or simply through the pursuit of a more explicit, intentional feeling type of interface, or perhaps this is just a case of trickle a down norm. What are your thoughts? And how would simple changes to these conventions impact your happiness / daily attitudes towards your craft (however minimal). Thanks.

    Read the article

  • (Android SDk 2.1) Getting error when I use setAudioSource and setVideoSource

    - by Rainfer
    I got the follow error when I run setAudioSource and setVideoSource. 03-16 10:26:25.302: ERROR/audio_input(52): unsupported parameter: x-pvmf/media-input-node/cap-config-interface;valtype=key_specific_value 03-16 10:26:25.302: ERROR/audio_input(52): VerifyAndSetParameter failed 03-16 10:26:25.302: ERROR/CameraInput(52): Unsupported parameter(x-pvmf/media-input-node/cap-config-interface;valtype=key_specific_value) 03-16 10:26:25.302: ERROR/CameraInput(52): VerifiyAndSetParameter failed on parameter #0 This error happen on both emulator and the device. (I am using Google nexus one) I have set the CAMERA and RECORD_AUDIO user permission already. I spent many days but I still cannot figure out what is the cause of this runtime error.

    Read the article

  • Does oneway declaration in Android .aidl guarantee that method will be called in a separate thread?

    - by Dan Menes
    I am designing a framework for a client/server application for Android phones. I am fairly new to both Java and Android (but not new to programming in general, or threaded programming in particular). Sometimes my server and client will be in the same process, and sometimes they will be in different processes, depending on the exact use case. The client and server interfaces look something like the following: IServer.aidl: package com.my.application; interface IServer { /** * Register client callback object */ void registerCallback( in IClient callbackObject ); /** * Do something and report back */ void doSomething( in String what ); . . . } IClient.aidl: package com.my.application; oneway interface IClient { /** * Receive an answer */ void reportBack( in String answer ); . . . } Now here is where it gets interesting. I can foresee use cases where the client calls IServer.doSomething(), which in turn calls IClient.reportBack(), and on the basis of what is reported back, IClient.reportBack() needs to issue another call to IClient.doSomething(). The issue here is that IServer.doSomething() will not, in general, be reentrant. That's OK, as long as IClient.reportBack() is always invoked in a new thread. In that case, I can make sure that the implementation of IServer.doSomething() is always synchronized appropriately so that the call from the new thread blocks until the first call returns. If everything works the way I think it does, then by declaring the IClient interface as oneway, I guarantee this to be the case. At least, I can't think of any way that the call from IServer.doSomething() to IClient.reportBack() can return immediately (what oneway is supposed to ensure), yet IClient.reportBack still be able to reinvoke IServer.doSomething recursively in the same thread. Either a new thread in IServer must be started, or else the old IServer thread can be re-used for the inner call to IServer.doSomething(), but only after the outer call to IServer.doSomething() has returned. So my question is, does everything work the way I think it does? The Android documentation hardly mentions oneway interfaces.

    Read the article

  • Why my VPN doesn't work anymore?

    - by xx77aBs
    I have openvpn server running on debian lenny. There is only one client - and it is running Windows 7 64-bit. This has worked for few months without any problems. And now, let's say for the last 7 days, it doesn't work at all. I connect successfully from client to the server, but I can't access anything through VPN. I have set it up so that all internet traffic is routed through VPN, and now when I connect with the client, the client can't do anything on the net (open any webpage, ping google, anything ...). Can you help me to figure out what's wrong ? I don't know where to start. I've also tried to connect to another openvpn server (I've installed and configured openvpn on another server, and when I try to connect to it result is the same). So I think there's something wrong with client ... Here is my connection log: Wed Apr 04 21:35:59 2012 OpenVPN 2.3-alpha1 Win32-MSVC++ [SSL (OpenSSL)] [LZO2] [PF_INET6] [IPv6 payload 20110522-1 (2.2.0)] built on Feb 21 2012 Enter Management Password: Wed Apr 04 21:35:59 2012 MANAGEMENT: TCP Socket listening on [AF_INET]127.0.0.10:25340 Wed Apr 04 21:35:59 2012 Need hold release from management interface, waiting... Wed Apr 04 21:36:00 2012 MANAGEMENT: Client connected from [AF_INET]127.0.0.10:25340 Wed Apr 04 21:36:00 2012 MANAGEMENT: CMD 'state on' Wed Apr 04 21:36:00 2012 MANAGEMENT: CMD 'log all on' Wed Apr 04 21:36:00 2012 MANAGEMENT: CMD 'hold off' Wed Apr 04 21:36:00 2012 MANAGEMENT: CMD 'hold release' Wed Apr 04 21:36:00 2012 WARNING: No server certificate verification method has been enabled. See http://openvpn.net/howto.html#mitm for more info. Wed Apr 04 21:36:00 2012 NOTE: OpenVPN 2.1 requires '--script-security 2' or higher to call user-defined scripts or executables Wed Apr 04 21:36:00 2012 Socket Buffers: R=[8192->8192] S=[8192->8192] Wed Apr 04 21:36:00 2012 MANAGEMENT: >STATE:1333568160,RESOLVE,,, Wed Apr 04 21:36:00 2012 UDPv4 link local: [undef] Wed Apr 04 21:36:00 2012 UDPv4 link remote: [AF_INET]11.22.33.44:1234 Wed Apr 04 21:36:00 2012 MANAGEMENT: >STATE:1333568160,WAIT,,, Wed Apr 04 21:36:00 2012 MANAGEMENT: >STATE:1333568160,AUTH,,, Wed Apr 04 21:36:00 2012 TLS: Initial packet from [AF_INET]11.22.33.44:1234, sid=ee329574 f15e9e04 Wed Apr 04 21:36:00 2012 VERIFY OK: depth=1, C=US, ST=CA, L=SanFrancisco, O=Fort-Funston, CN=Fort-Funston CA, [email protected] Wed Apr 04 21:36:00 2012 VERIFY OK: depth=0, C=US, ST=CA, L=SanFrancisco, O=Fort-Funston, CN=server_key, [email protected] Wed Apr 04 21:36:01 2012 Data Channel Encrypt: Cipher 'BF-CBC' initialized with 128 bit key Wed Apr 04 21:36:01 2012 Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Wed Apr 04 21:36:01 2012 Data Channel Decrypt: Cipher 'BF-CBC' initialized with 128 bit key Wed Apr 04 21:36:01 2012 Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Wed Apr 04 21:36:01 2012 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Wed Apr 04 21:36:01 2012 [server_key] Peer Connection Initiated with [AF_INET]11.22.33.44:1234 Wed Apr 04 21:36:02 2012 MANAGEMENT: >STATE:1333568162,GET_CONFIG,,, Wed Apr 04 21:36:03 2012 SENT CONTROL [server_key]: 'PUSH_REQUEST' (status=1) Wed Apr 04 21:36:03 2012 PUSH: Received control message: 'PUSH_REPLY,redirect-gateway def1,route 172.16.100.1,topology net30,ping 10,ping-restart 120,ifconfig 172.16.100.6 172.16.100.5' Wed Apr 04 21:36:03 2012 OPTIONS IMPORT: timers and/or timeouts modified Wed Apr 04 21:36:03 2012 OPTIONS IMPORT: --ifconfig/up options modified Wed Apr 04 21:36:03 2012 OPTIONS IMPORT: route options modified Wed Apr 04 21:36:03 2012 ROUTE_GATEWAY 192.168.1.1/255.255.255.0 I=15 HWADDR=00:1f:1f:3f:61:55 Wed Apr 04 21:36:03 2012 do_ifconfig, tt->ipv6=0, tt->did_ifconfig_ipv6_setup=0 Wed Apr 04 21:36:03 2012 MANAGEMENT: >STATE:1333568163,ASSIGN_IP,,172.16.100.6, Wed Apr 04 21:36:03 2012 open_tun, tt->ipv6=0 Wed Apr 04 21:36:03 2012 TAP-WIN32 device [VPN] opened: \\.\Global\{E28FD52B-F6C3-4094-A36A-30CB02FAC7E8}.tap Wed Apr 04 21:36:03 2012 TAP-Win32 Driver Version 9.9 Wed Apr 04 21:36:03 2012 Notified TAP-Win32 driver to set a DHCP IP/netmask of 172.16.100.6/255.255.255.252 on interface {E28FD52B-F6C3-4094-A36A-30CB02FAC7E8} [DHCP-serv: 172.16.100.5, lease-time: 31536000] Wed Apr 04 21:36:03 2012 Successful ARP Flush on interface [31] {E28FD52B-F6C3-4094-A36A-30CB02FAC7E8} Wed Apr 04 21:36:08 2012 TEST ROUTES: 2/2 succeeded len=1 ret=1 a=0 u/d=up Wed Apr 04 21:36:08 2012 C:\Windows\system32\route.exe ADD 11.22.33.44 MASK 255.255.255.255 192.168.1.1 Wed Apr 04 21:36:08 2012 ROUTE: CreateIpForwardEntry succeeded with dwForwardMetric1=25 and dwForwardType=4 Wed Apr 04 21:36:08 2012 Route addition via IPAPI succeeded [adaptive] Wed Apr 04 21:36:08 2012 C:\Windows\system32\route.exe ADD 0.0.0.0 MASK 128.0.0.0 172.16.100.5 Wed Apr 04 21:36:08 2012 ROUTE: CreateIpForwardEntry succeeded with dwForwardMetric1=30 and dwForwardType=4 Wed Apr 04 21:36:08 2012 Route addition via IPAPI succeeded [adaptive] Wed Apr 04 21:36:08 2012 C:\Windows\system32\route.exe ADD 128.0.0.0 MASK 128.0.0.0 172.16.100.5 Wed Apr 04 21:36:08 2012 ROUTE: CreateIpForwardEntry succeeded with dwForwardMetric1=30 and dwForwardType=4 Wed Apr 04 21:36:08 2012 Route addition via IPAPI succeeded [adaptive] Wed Apr 04 21:36:08 2012 MANAGEMENT: >STATE:1333568168,ADD_ROUTES,,, Wed Apr 04 21:36:08 2012 C:\Windows\system32\route.exe ADD 172.16.100.1 MASK 255.255.255.255 172.16.100.5 Wed Apr 04 21:36:08 2012 ROUTE: CreateIpForwardEntry succeeded with dwForwardMetric1=30 and dwForwardType=4 Wed Apr 04 21:36:08 2012 Route addition via IPAPI succeeded [adaptive] Wed Apr 04 21:36:08 2012 Initialization Sequence Completed Wed Apr 04 21:36:08 2012 MANAGEMENT: >STATE:1333568168,CONNECTED,SUCCESS,172.16.100.6,11.22.33.44 Client's route table after connection with OpenVPN: IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 192.168.1.1 192.168.1.41 281 0.0.0.0 128.0.0.0 172.16.100.1 172.16.100.6 31 94.23.53.45 255.255.255.255 192.168.1.1 192.168.1.41 25 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 128.0.0.0 128.0.0.0 172.16.100.1 172.16.100.6 31 172.16.100.4 255.255.255.252 On-link 172.16.100.6 286 172.16.100.6 255.255.255.255 On-link 172.16.100.6 286 172.16.100.7 255.255.255.255 On-link 172.16.100.6 286 192.168.1.0 255.255.255.0 On-link 192.168.1.41 281 192.168.1.41 255.255.255.255 On-link 192.168.1.41 281 192.168.1.255 255.255.255.255 On-link 192.168.1.41 281 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 192.168.1.41 281 224.0.0.0 240.0.0.0 On-link 172.16.100.6 286 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 192.168.1.41 281 255.255.255.255 255.255.255.255 On-link 172.16.100.6 286 =========================================================================== Persistent Routes: Network Address Netmask Gateway Address Metric 0.0.0.0 0.0.0.0 192.168.1.1 Default =========================================================================== IPv6 Route Table =========================================================================== Active Routes: If Metric Network Destination Gateway 13 58 ::/0 On-link 1 306 ::1/128 On-link 13 58 2001::/32 On-link 13 306 2001:0:5ef5:79fd:3cc3:6b9:ac7c:14db/128 On-link 15 281 fe80::/64 On-link 31 286 fe80::/64 On-link 13 306 fe80::/64 On-link 13 306 fe80::3cc3:6b9:ac7c:14db/128 On-link 31 286 fe80::7d72:9515:7213:35e3/128 On-link 15 281 fe80::9cec:ce3f:89de:a123/128 On-link 1 306 ff00::/8 On-link 13 306 ff00::/8 On-link 15 281 ff00::/8 On-link 31 286 ff00::/8 On-link =========================================================================== Persistent Routes: None

    Read the article

  • When is it worth using a BindingSource?

    - by Justin
    I think I understand well enough what the BindingSource class does - i.e. provide a layer of indirection between a data source and a UI control. It implements the IBindingList interface and therefore also provides support for sorting. And I've used it frequently enough, without too many problems. But I'm wondering if I use it more often than I should. Perhaps an example would help. Let's say I have just a simple textbox on a form (using WinForms), and I'd like to bind that textbox to a simple property inside a class that returns a string. Is it worth using a BindingSource in this situation? Now let's say I have a grid on my form, and I'd like to bind it to a DataTable. Should I use a BindingSource now? In the latter case, I probably would not use a BindingSource, as a DataTable, from what I can gather, provides the same functionality that the BindingSource itself would. The DataTable will fire the the right events when a row is added, deleted, etc so that the grid will automatically update. But in the first case with the textbox being bound to a string, I would probably have the class that contains the string property implement INotifyPropertyChanged, so that it could fire the PropertyChanged event when the string changes. I would use a BindingSource so that it could listen to these PropertyChanged events so that it could update the textbox automatically when the string changes. How does this sound so far? I still feel like there's a gap in my understanding that's preventing me from seeing the whole picture. This has been a pretty vague question so far, so I'll try to ask some more specific questions - ideally the answers will reference the above examples or something similar... (1) Is it worth using a BindingSource in either of the above examples? (2) It seems that developers just "assume" that the DataTable class will do the right thing, in firing PropertyChanged events at the right time. How does one know if a data source is capable of doing this? Is there a particular interface that a data source should implement in order for developers to be able to assume this behaviour? (3) Does it matter what Control is being bound to, when considering whether or not to use a BindingSource? Or is it only the data source that should affect the decision? Perhaps the answer is (and this would seem logical enough): the Control needs to be intelligent enough to listen to the PropertyChanged events, otherwise a BindingSource is required. So how does one tell if the Control is capable of doing this? Again, is there a particular interface that developers can look for that the Control must implement? It is this confusion that has, in the past, led to me always using a BindingSource. But I'd like to understand better exactly when to use one, so that I do so only when necessary.

    Read the article

  • GWT 2.X No resource found for key

    - by Han Fastolfe
    I've developed a GWT app using i18n internationalization. In Host/Dev mode it works fine, but launching GWT compile gives this error: No resource found for key xxx, like below. Compiling module ...rte.RTE Scanning for additional dependencies: file:/home/.../client/i18n/RTEValidationMessages.java Computing all possible rebind results for '...client.i18n.RTEMessages' Rebinding ...client.i18n.RTEMessages Invoking com.google.gwt.dev.javac.StandardGeneratorContext@e7dfd0 Processing interface ...client.i18n.RTEMessages Generating method body for txtIndirizzo3() [ERROR] No resource found for key 'txtIndirizzo3' Messages are loaded with late binding. public class RTEValidationMessages { private RTEMessages additionalMessages; public RTEValidationMessages() { additionalMessages = GWT.create(RTEMessages.class); } } Deleting the method which gives the error, results in another random method with error, say not the method before or after in the interface ...client.i18n.RTEMessages. Help is greatly appreciated.

    Read the article

  • unittest tests reuse for family of classes

    - by zaharpopov
    I have problem organizing my unittest based class test for family of tests. For example assume I implement a "dictionary" interface, and have 5 different implementations want to testing. I do write one test class that tests a dictionary interface. But how can I nicely reuse it to test my all classes? So far I do ugly: DictType = hashtable.HashDict In top of file and then use DictType in test class. To test another class I manually change the DictType to something else. How can do this otherwise? Can't pass arguments to unittest classes so is there a nicer way?

    Read the article

  • Building Visual studio like application, need inputs..

    - by akjoshi
    Hi, I am working on a Visual studio like application i.e. hava a tolbox, an editor and property grid similar to VS. ser can drag and drop the controls(custom and third party) to the editor window and perform operations like resize, move, align, group etc.; Properties of that control needs to be displayed in property grid and user can update them from there. As per my current understanding I will have to extend the Canvas to create my own editor and and Interface for controls which it supports; Each supported control will have to implemnt this interface so that it can be placed in our editor. Something similar to this - http://www.codeproject.com/KB/WPF/WPFDiagramDesigner_Part4.aspx Looking forward for any kind of help, comment or links.

    Read the article

  • Are SOLID principles really solid?

    - by Arseny
    The first pattern stands for this acronym is SRP. Here is a quote. the single responsibility principle states that every object should have a single responsibility, and that responsibility should be entirely encapsulated by the class. That's is simple and clear till we start to code ) Suppose we have a class with well defined SRP. To serialize this class instances we need to add special atrributes to that class. So now the class have other responsibility. Dosen't it violate SRP? Let's see other story. Interface implementation. Then we implement an interface we simply add other responsibility say dispose its resorces or compare its instances or whatever. So my question. Is it possible to keep SRP complete? How can we do it?

    Read the article

  • Getting Service Tag from Dell Machine using .net?

    - by JonH
    Hello folks I've got a class that pulls model information (hardware info) for a local machine code is like so: Imports System.Management Public Class clsWMI Private objOS As ManagementObjectSearcher Private objCS As ManagementObjectSearcher Private objMgmt As ManagementObject Private m_strComputerName As String Private m_strManufacturer As String Private m_StrModel As String Private m_strOSName As String Private m_strOSVersion As String Private m_strSystemType As String Private m_strTPM As String Private m_strWindowsDir As String Public Sub New() objOS = New ManagementObjectSearcher("SELECT * FROM Win32_OperatingSystem") objCS = New ManagementObjectSearcher("SELECT * FROM Win32_ComputerSystem") For Each objMgmt In objOS.Get m_strOSName = objMgmt("name").ToString() m_strOSVersion = objMgmt("version").ToString() m_strComputerName = objMgmt("csname").ToString() m_strWindowsDir = objMgmt("windowsdirectory").ToString() Next For Each objMgmt In objCS.Get m_strManufacturer = objMgmt("manufacturer").ToString() m_StrModel = objMgmt("model").ToString() m_strSystemType = objMgmt("systemtype").ToString m_strTPM = objMgmt("totalphysicalmemory").ToString() Next End Sub Public ReadOnly Property ComputerName() Get ComputerName = m_strComputerName End Get End Property Public ReadOnly Property Manufacturer() Get Manufacturer = m_strManufacturer End Get End Property Public ReadOnly Property Model() Get Model = m_StrModel End Get End Property Public ReadOnly Property OsName() Get OsName = m_strOSName End Get End Property Public ReadOnly Property OSVersion() Get OSVersion = m_strOSVersion End Get End Property Public ReadOnly Property SystemType() Get SystemType = m_strSystemType End Get End Property Public ReadOnly Property TotalPhysicalMemory() Get TotalPhysicalMemory = m_strTPM End Get End Property Public ReadOnly Property WindowsDirectory() Get WindowsDirectory = m_strWindowsDir End Get End Property End Class Any possibility to get a service tag from WMI ? From the client side form I display values like so: Dim objWMI As New clsWMI() With objWMI Debug.WriteLine("Computer Name = " & .ComputerName) Me.Label1.Text = "Name: " & .ComputerName Debug.WriteLine("Computer Manufacturer = " & .Manufacturer) Me.Label2.Text = "Manufacturer: " & .Manufacturer Debug.WriteLine("Computer Model = " & .Model) Me.Label3.Text = "Model: " & .Model Debug.WriteLine("OS Name = " & .OsName) Me.Label4.Text = "OS Name: " & .OsName Debug.WriteLine("OS Version = " & .OSVersion) Me.Label5.Text = "OS VERSION: " & .OSVersion Debug.WriteLine("System Type = " & .SystemType) Me.Label6.Text = "System type = " & .SystemType Debug.WriteLine("Total Physical Memory = " & .TotalPhysicalMemory) Me.Label7.Text = "Memory: " & .TotalPhysicalMemory Debug.WriteLine("Windows Directory = " & .WindowsDirectory) Me.Label8.Text = "Win Directory: " & .WindowsDirectory End With

    Read the article

  • Setting a date format in ASP.NET web.config globalization tag?

    - by Jens Ameskamp
    In our web.config I am using the following tag to determine the interface language of an ASP.NET website. <globalization enableClientBasedCulture="true" culture="auto:en-GB" uiCulture="auto:en"/> This works as expected: Client wo request a specific localisation get it, everybody else is happily looking at the en-GB settings. Due to company policy I need to change the date format to the ISO 8601 standard format (YYYY-MM-DD) for everybody. Is this possible at a central place in the web.config or do I need to change this manually in every instance? Addition: Would it be possible to do get this date format when restricting the interface to english? Thanks! =)

    Read the article

  • How do I mirror a SVN repository on CodePlex?

    - by James Curran
    I'm the creator (and so far, only developer) of a CodePlex project. I've writing it on my laptop, using a Subversion repository on my home network. Submitting my changes to CodePlex via the TeamServer interface is driving me crazy, and I'd really like a simple way of syncing my svn repos with CodePlex via there new SVN interface. svnsync or synmerge seem to be the way to go, but neither's instructions seem clear to a guy who's only ever used TortoiseSVN. And they seem to also seem need local access to the destination server (which clearly for CodePlex, is impossible) So, could someone give simple instructions how to do this?

    Read the article

  • Create a VPN with Python

    - by user213060
    I want to make a device "tunnel box" that you plug an input ethernet line, and an output ethernet line, and all the traffic that goes through it gets modified in a special way. This is similar to how a firewall, IDS, VPN, or similar boxes are connected inline in a network. I think you can just assume that I am writing a custom VPN in Python for the purpose of this question: LAN computer <--\ LAN computer <---> [LAN switch] <--> ["tunnel box"] <--> [internet modem] <--> LAN computer <--/ My question is, what is a good way to program this "tunnel box" from python? My application needs to see TCP flows at the network layer, not as individual ethernet frames. Non-TCP/IP traffic such as ICPM and other types should just be passed through. Example Twisted-like Code for my "tunnel box" tunnel appliance: from my_code import special_data_conversion_function class StreamInterceptor(twisted.Protocol): def dataReceived(self,data): data=special_data_conversion_function(data) self.outbound_connection.send(data) My initial guesses: TUN/TAP with twisted.pair.tuntap.py - Problem: This seems to only work at the ethernet frame level, not like my example? Socks proxy - Problem: Not transparent as in my diagram. Programs have to be specifically setup for it. Thanks!

    Read the article

  • How to use imported css styles in GWT correctly

    - by Eduard Wirch
    Imagine you created the following simple widget with UiBinder: <!DOCTYPE ui:UiBinder SYSTEM "http://dl.google.com/gwt/DTD/xhtml.ent"> <ui:UiBinder xmlns:ui="urn:ui:com.google.gwt.uibinder" xmlns:g="urn:import:com.google.gwt.user.client.ui"> <ui:style type="my.package.Widget1.Widget1Style"> .childWidgetStyle { border-width: 1px; border-style: dotted; } </ui:style> <g:TextArea styleName="{style.childWidgetStyle}"/> </ui:UiBinder> package my.package; // some imports here public class Widget1 extends Composite { private static Widget1UiBinder uiBinder = GWT.create(Widget1UiBinder.class); interface Widget1UiBinder extends UiBinder<Widget, Widget1> { } public interface Widget1Style extends CssResource { String childWidgetStyle(); } @UiField TextArea textArea; public Widget1(String text) { initWidget(uiBinder.createAndBindUi(this)); textArea.setText(text); } } Than you use this simple widget in another (parent) widget you created: <!DOCTYPE ui:UiBinder SYSTEM "http://dl.google.com/gwt/DTD/xhtml.ent"> <ui:UiBinder xmlns:ui="urn:ui:com.google.gwt.uibinder" xmlns:g="urn:import:com.google.gwt.user.client.ui"> <ui:style> .parentWidgetStyle .childWidgetStyle { margin-bottom: 10px; } </ui:style> <g:VerticalPanel ui:field="listPanel" addStyleNames="{style.parentWidgetStyle}" /> </ui:UiBinder> package my.package; // imports go here public class ParentWidget extends Composite { private static ParentWidgetUiBinder uiBinder = GWT.create(ParentWidgetUiBinder.class); interface ParentWidgetUiBinder extends UiBinder<Widget, ParentWidget> { } @UiField VerticalPanel listPanel; public ParentWidget(final String... texts) { initWidget(uiBinder.createAndBindUi(this)); for (final String text : texts) { final Widget1 entry = new Widget1(text); listPanel.add(entry); } } } What you want to achieve is to get some margin between the Widget1 entries in the list using css. But this won't work. Because GWT will obfuscate the css names. And the obfuscated name for .childWidgetStyle in ParentWidget will be different from the .childWidgetStyle in Widget1. The resulting css will look similar to this: .G1unc9fbE { border-style:dotted; border-width:1px; } .G1unc9fbBB .G1unc9fDa { margin-bottom:10px; } So the margin setting wont apply. How do I do this correctly?

    Read the article

  • using WrapCompressedRTFStream in C#

    - by Code Smack
    Hello, I am rewording this question: Csharp C# visual studio 2008 How do I use the WrapCompressedRTFStream when using DLLImport with mapi32.dll? Sample of code to import the WrapCompressedRTFStream method. (I found this, I did not figure this part out) [DllImport("Mapi32.dll", PreserveSig = true)] private static extern void WrapCompressedRTFStream( [MarshalAs(UnmanagedType.Interface)] UCOMIStream lpCompressedRTFStream, uint ulflags, [MarshalAs(UnmanagedType.Interface)] out UCOMIStream lpUncompressedRTFStream ); public const uint MAPI_MODIFY = 0x00000001; public const uint STORE_UNCOMPRESSED_RTF = 0x00008000; How do I use this in my c# application when my compressedRichText is stored in a string.

    Read the article

  • passing user from UITableView to UIWebView based on selection

    - by ct2k7
    Hello, I'm trying to pass the user on to the interface based on their cell selection in the UITableView, ie, if the user selects cell 1, they are taken to view model 2, containing UIWebView. UIWebView then displays local file, cell1.html. Currently, I've manage to get placeholder using: selectedCellText.text = selectedCell; to display the name of the cell selected. How do I get it to directly pass to the UIWebView, stick UIWebView in the interface and link it using: UIWebView *myWebView = [[UIWebView alloc] initWithFrame:frame]; NSBundle *mainBundle = [NSBundle mainBundle]; NSString *stringUrl = [mainBundle pathForResource:@"selectedCell" ofType:@"html"]; NSURL *baseUrl = [NSURL fileURLWithPath:stringUrl]; NSURLRequest *urlRequest = [NSURLRequest requestWithURL:baseUrl]; [myWebView loadRequest:urlRequest]; My other issue is that some of the cell names have spaces in them, and for simplicity, I'd like to ensure that there are no spaces (actually, will it even work with spaces in the name, I assume with %20 ? Thanks

    Read the article

  • Weird Mono compilation error

    - by nubela
    Hi, I am using IKVM to get SVNKit on a Mono project I'm working with, I have a class that implements an interface from SVNKit, and I can't compile: On windows and on .NET, everything compiles fine, just getting this on Mono. /home/nubela/Workspace/subsync/subsync/Core/Subversion/PropGetHandler.cs(22,22): Error CS0535: Subsync.Core.Subversion.PropGetHandler' does not implement interface member org.tmatesoft.svn.core.wc.ISVNPropertyHandler.__()' (CS0535) (subsync) I googled _() method, and it seems to be the initializer method for the base class in the Java library compiled from IKVM. I have no clue how to proceed now, any idea guys? :)

    Read the article

  • NavigationController pushViewController problems.

    - by Jacek
    Hello. I have created new a view controller in my project (ActivateController). I have added it to the interface of the parent view controller (PrefsViewController): #import <UIKit/UIKit.h> #import "ActivateController.h" @interface PrefsViewController : UIViewController <UITextFieldDelegate> { ActivateController *activateController; } -(IBAction)pressedActivate; @property(nonatomic,retain) IBOutlet ActivateController *activateController; @end I have also added it to parent's controller nib (and changed it type to ActivateController), and connected it to IBOutlet ActivateController. But still, when I perform (on pressedActivate): [self.navigationController pushViewController:activateController animated:YES]; Nothing happens. I have done it successfully many times before. What might be wrong? P.S. pressedActivate is executed for sure (I used NSLog to check).

    Read the article

  • Newbie questions about COM

    - by smwikipedia
    Hi, I am quite new to COM so the question may seem naive. Q1. About Windows DLL Based on my understanding, a Windows DLL can export functions, types(classes) and global variables. Is this understanding all right? Q2. About COM My naive understanding is that: a COM DLL seems to be just a new logical way to organize the functions and types exported by a standard Windows DLL. A COM DLL exports both functions such as DllRegisterServer() and DllGetClassObject(), and also the Classes which implements the IUnknown interface. Is this understanding all right? Q3. *.def & *.idl *.def is used to define the functions exported by a Windows DLL in the traditional way, such as DllGetClassObject(). *.idl is used to define the interface implemented by a COM coclass. Thanks in advance.

    Read the article

< Previous Page | 346 347 348 349 350 351 352 353 354 355 356 357  | Next Page >