Search Results

Search found 5287 results on 212 pages for 'physical computing'.

Page 36/212 | < Previous Page | 32 33 34 35 36 37 38 39 40 41 42 43  | Next Page >

  • How is a VM isolated from the physical host?

    - by dotnetdev
    Hi, I was thinking about virtualisation and how to explain it to a non-technical person and one of the things that I was wondering was how to explain the way that a VM is isolated and seperate from the phyiscal machine (so I can have a virus on a VM but this would never effect my physical host, right?). How does this technology work exactly? As I am a programmer, when I think of isolating processes, I think of using appdomains (I work with C# primarily). Thanks

    Read the article

  • How to get physical partition name from iSCSI details on Windows?

    - by Barry Kelly
    I've got a piece of software that needs the name of a partition in \Device\Harddisk2\Partition1 style, as shown e.g. in WinObj. I want to get this partition name from details of the iSCSI connection that underlies the partition. The trouble is that disk order is not fixed - depending on what devices are connected and initialized in what order, it can move around. So suppose I have the portal name (DNS of the iSCSI target), target IQN, etc. I'd like to somehow discover which volumes in the system relate to it, in an automated fashion. I can write some PowerShell WMI queries that get somewhat close to the desired info: PS> get-wmiobject -class Win32_DiskPartition NumberOfBlocks : 204800 BootPartition : True Name : Disk #0, Partition #0 PrimaryPartition : True Size : 104857600 Index : 0 ... From the Name here, I think I can fabricate the corresponding name by adding 1 to the partition number: \Device\Harddisk0\Partition1 - Partition0 appears to be a fake partition mapping to the whole disk. But the above doesn't have enough information to map to the underlying physical device, unless I take a guess based on exact size matching. I can get some info on SCSI devices, but it's not helpful in joining things up (iSCSI target is Nexenta/Solaris COMSTAR): PS> get-wmiobject -class Win32_SCSIControllerDevice __GENUS : 2 __CLASS : Win32_SCSIControllerDevice ... Antecedent : \\COBRA\root\cimv2:Win32_SCSIController.DeviceID="ROOT\\ISCSIPRT\\0000" Dependent : \\COBRA\root\cimv2:Win32_PnPEntity.DeviceID="SCSI\\DISK&VEN_NEXENTA&PROD_COMSTAR... Similarly, I can run queries like these: PS> get-wmiobject -namespace ROOT\WMI -class MSiSCSIInitiator_TargetClass PS> get-wmiobject -namespace ROOT\WMI -class MSiSCSIInitiator_PersistentDevices These guys return information relating to my iSCSI target name and the GUID volume name respectively (a volume name like \\?\Volume{guid-goes-here}), but the GUID volume name is no good to me, and there doesn't appear to be a reliable correspondence between the target name and the volume that I can join on. I simply can't find an easy way of getting from an IQN (e.g. iqn.1992-01.com.example:storage:diskarrays-sn-a8675309) to physical partitions mapped from that target. The way I do it by hand? I start Disk Management, and look for a partition of the correct size, verify that its driver says NEXENTA COMSTAR, and look at the disk number. But even this is unreliable if I have multiple iSCSI volumes of the exact same size. Any suggestions?

    Read the article

  • How to change a physical partition system to LVM?

    - by Daniel Hernández
    I have a server with Debian that have 3 physical partitions covering all the disk: boot, root y swap. Now I want to replace that partitions with LVM partitions. I know how install Debian with LVM at beginning, but in this case I can't install the system at beginning because the provider gets me a server with remote access and the system installed in this way. How can I change that partitions using only an ssh connection and possibly other remote server where to put some temporal data?

    Read the article

  • I need to monitor a physical RS232 port on an appliance?

    - by Kendor
    I need to verify what's being output on an RS232 port of an appliance that's running proprietary software (e.g. NOT Windows or Linux). The port is sending data to a target app on another appliance, but I need to verify/log the actual data raw outside of the appliances. Would appreciate a recommendation on process/software to attach to the physical sending port (I have a straight through RS232 cable) and grab sample output of that port.

    Read the article

  • Is it possible to dedicate the physical screen of a vmware server machine to a guest vm graphically?

    - by matnagel
    I have a vmware server 2.x running on ubuntu server (8.04). So the graphics card and the screen of the physical box are unused (I log in remotely and the host os has only the cli console installed). I wonder if it is possible to assign this graphics card to a virtual machine directly and use it for the gui of this guest? Or maybe if I add a second graphics card to the machine?

    Read the article

  • Physical button to run scripts on a windows machine?

    - by NoCarrier
    I frequently come in contact with people who absolutely cannot operate a PC, no matter how you train them. I need some sort of programmable physical button or remote control, where when they click it, it will execute a script on a windows machine. (and no, wiseguys, a mouse won't do) Does such a thing exist?

    Read the article

  • composite-video-to-usb adaptor

    - by sawa
    I bought a composite-video-to-usb adaptor. I want to stream video game in ubuntu. How can I do that? My environment: Monoprice USB Video and Audio Grabber Ubuntu 11.04 The relevant output of lsusb: Bus 001 Device 011: ID 0572:262a Conexant Systems (Rockwell), Inc. The relevant output of sudo lshw: *-usb:0 description: USB Controller product: 82801JI (ICH10 Family) USB UHCI Controller #4 vendor: Intel Corporation physical id: 1a bus info: pci@0000:00:1a.0 version: 00 width: 32 bits clock: 33MHz capabilities: uhci bus_master cap_list configuration: driver=uhci_hcd latency=0 resources: irq:16 ioport:f0e0(size=32) *-usb:1 description: USB Controller product: 82801JI (ICH10 Family) USB UHCI Controller #5 vendor: Intel Corporation physical id: 1a.1 bus info: pci@0000:00:1a.1 version: 00 width: 32 bits clock: 33MHz capabilities: uhci bus_master cap_list configuration: driver=uhci_hcd latency=0 resources: irq:21 ioport:f0c0(size=32) *-usb:2 description: USB Controller product: 82801JI (ICH10 Family) USB UHCI Controller #6 vendor: Intel Corporation physical id: 1a.2 bus info: pci@0000:00:1a.2 version: 00 width: 32 bits clock: 33MHz capabilities: uhci bus_master cap_list configuration: driver=uhci_hcd latency=0 resources: irq:18 ioport:f0a0(size=32) *-usb:3 description: USB Controller product: 82801JI (ICH10 Family) USB2 EHCI Controller #2 vendor: Intel Corporation physical id: 1a.7 bus info: pci@0000:00:1a.7 version: 00 width: 32 bits clock: 33MHz capabilities: pm debug ehci bus_master cap_list configuration: driver=ehci_hcd latency=0 resources: irq:18 memory:e0525c00-e0525fff *-multimedia description: Audio device product: 82801JI (ICH10 Family) HD Audio Controller vendor: Intel Corporation physical id: 1b bus info: pci@0000:00:1b.0 version: 00 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=HDA Intel latency=0 resources: irq:43 memory:e0520000-e0523fff *-usb:4 description: USB Controller product: 82801JI (ICH10 Family) USB UHCI Controller #1 vendor: Intel Corporation physical id: 1d bus info: pci@0000:00:1d.0 version: 00 width: 32 bits clock: 33MHz capabilities: uhci bus_master cap_list configuration: driver=uhci_hcd latency=0 resources: irq:23 ioport:f080(size=32) *-usb:5 description: USB Controller product: 82801JI (ICH10 Family) USB UHCI Controller #2 vendor: Intel Corporation physical id: 1d.1 bus info: pci@0000:00:1d.1 version: 00 width: 32 bits clock: 33MHz capabilities: uhci bus_master cap_list configuration: driver=uhci_hcd latency=0 resources: irq:19 ioport:f060(size=32) *-usb:6 description: USB Controller product: 82801JI (ICH10 Family) USB UHCI Controller #3 vendor: Intel Corporation physical id: 1d.2 bus info: pci@0000:00:1d.2 version: 00 width: 32 bits clock: 33MHz capabilities: uhci bus_master cap_list configuration: driver=uhci_hcd latency=0 resources: irq:18 ioport:f040(size=32) *-usb:7 description: USB Controller product: 82801JI (ICH10 Family) USB2 EHCI Controller #1 vendor: Intel Corporation physical id: 1d.7 bus info: pci@0000:00:1d.7 version: 00 width: 32 bits clock: 33MHz capabilities: pm debug ehci bus_master cap_list configuration: driver=ehci_hcd latency=0 resources: irq:23 memory:e0525800-e0525bff The relevant output of dmesg: [18953.220035] usb 1-1: new high speed USB device using ehci_hcd and address 6 [19964.761076] Linux video capture interface: v2.00 [19964.767112] usbcore: registered new interface driver uvcvideo [19964.767115] USB Video Class driver (v1.0.0)

    Read the article

  • How do I make a VMDK format virtual hard drive from a physical partition on a disk?

    - by Ahmad
    I have a 320 GB HDD, which actually only has an 80 GB NTFS format partition which was being used by a Windows 7 system ... I want to create a VMDK format clone of this partition, so that I can use it with VMware .. However, tradition VMDK creation programs normally make a VMDK for an entire disk, whereas I just want to make a VMDK for the one 80 GB partition ... This is important because the other 240 GB on the physical source HDD is just unallocated area, and including that in a VMDK file is just a plain waste of space .. So how to make a VMDK file for a specific partition ? Any tool available for this ?

    Read the article

  • Worth it to move /var to physical disk vs logical?

    - by Tammer Ibrahim
    Brief question about partition layout. I use an SSD for /, /boot, /usr, & /home partitions. I'd like to move /var to a mechanical disk to minimize writes to the SSD. I'm mainly concerned about maximizing drive life rather than maximizing performance (although I obviously wouldn't want to cripple my server). My mechanical disks consist of two drives sharing LVM, and a third used for nightly rsync backups. I also have a bunch of old 2.5in hard disks lying around. My question is, should I simply create a new LVM volume '/var' on my primary data store, or would it be worth the increased energy consumption (in terms of maximizing the lifetime of the LVMed drives) to install a low volume 2.5in disk to use just for /var? On a more general level my question is about the trade offs of placing OS mounts on the same physical volumes as my data. Thanks for any help!

    Read the article

  • Move virtual machine hard disk to a separate physical hard disk for better performance?

    - by joeeoj
    I have a dual-core machine with the host OS and many guest virtual OSs. Although I have 8GB of RAM, I notice a slowdown when I turn some virtual machine on (and it takes only 1GB RAM). I was told that I should move virtual machine hard disk file to a separate (another) physical hard drive in my PC to get better performance. This way the head of the hard disk would not have to jump from the virtual OS to the host OS as each hard drive would have its own head to deal with the OS: hard drive 1 head for host OS and hard drive 2 head for guest OS. Is this true? Should I get another hard disk only for virtual machine hard disk files?

    Read the article

  • how to? 1 domain name, 1 ISP Static IP, 1 router, 3 physical web Servers

    - by buliwyf
    I have 1 Static IP from my ISP, 58.59.60.61 I have 3 local physical web servers: Win2008 IIS 7, local IP 192.168.10.11, mydomain.com Ubuntu Apache2, local IP 192.168.10.12, subdomain1.mydomain.com Win2003 IIS 6, local IP 192.168.10.13, subdomain2.mydomain.com I have 1 domain name, mydomain.com. It is configured this way: Host(A), @, 58.59.60.61 Host(A), subdomain1, 58.59.60.61 Host(A), subdomain2, 58.59.60.61 My router is a pfSense box. It forwards all port 80 traffic to a group alias called "WebServers," which is my 3 web server IP's. This setup should work right? I believe I need to set the "host header names" in my web servers. In IIS I know how to do this. How do I do this in Apache2?

    Read the article

  • How to tell which physical disks have bootable MBR?

    - by Jon
    The computer I am using right now has 6 physical disks attached. Using the BIOS's "select boot device" functionality I have discovered that I can boot off 3 of these disks into the exact same bootloader. This means that all of these disks have the bootable flag set on their MBR, even though I had been under the impression that only 2 of them are in fact bootable. My question is: is there an easy way to check which disks have a bootable MBR with a command line tool or some OS utility? I am aware of the DISKPART tool and its basic functionality, but I haven't found how to view the information I need. The OS is Windows 7 x64 Ultimate with SP1.

    Read the article

  • Can someone explain the physical architecture of RAID 10 in complete layman's terms?

    - by Hank
    I am a newbie in the world of storage and I am having a hard time digesting the physical architecture of some of the RAID levels. I am particularly interested in RAID 10, and 50. I asked the question specifically about RAID 10, because I feel if I understand that, I'll understand the other. So, I get the definition of RAID 10 - "minimum 4 disks, a striped array whose segments are mirrored". If I've got 4 disks and Disks 1 and 2 are a mirrored pair, and Disks 3 and 4 are a mirrored pair - where does the data get striped? Thanks.

    Read the article

  • does the *physical* order/location of drives in a mdadm-managed RAID-10 array matter?

    - by locuse
    i've setup a 4-drive RAID-10 array using mdadm-managed, software-raid on an x86_64 box. it'd up & running and works as expected, cat /proc/mdstat md127 : active raid10 sdc2[2] sdd2[3] sda2[0] sdb2[1] 1951397888 blocks super 1.2 512K chunks 2 far-copies [4/4] [UUUU] bitmap: 9/466 pages [36KB], 2048KB chunk atm the four SATA drives are physically plugged into the motherboard's 1st four SATA ports. i'd like to gather the necessary/complete info for catastrophic recovery. reading starting here, http://neil.brown.name/blog, and the mailing list, i'm not yet completely confident i have it right. i understand 'drive order matters'. is that logical, &/or physical order that matters? if i unplugged the four drives in this array, and plugged them each back into different ports on the motherboard or a pci card, as long as i've changed nothing in software config, will the array correctly auto-re-assemble?

    Read the article

  • Putting two physical hard drives in a single 2.5" bay?

    - by dgw
    My crazy brain came up with this ridiculous idea. "Why can't I have a single 2.5" drive device that actually contains two independent hard drives? I want RAID 1 data mirroring and the security of having redundant drives. This is a thing that must exist!" To be clear, I am not asking if I can somehow shoehorn two 2.5" drives into a single bay, replace an optical drive with an additional HDD, or anything like that. What I have in mind is a single 2.5"-form-factor device that houses two independent hard drives, with separate housings (likely) and distinct controllers. Probably all they'd need to share is the power & SATA connections. Probably no such thing exists, but because I know there exist hard drives the physical size of a stack of postage stamps (roughly), I have to ask.

    Read the article

  • Get corresponding physical disk drives of mountpoints with WMI queries?

    - by Thomas
    Is there a way to retrieve a connection between a mountpoint (a volume which is mounted into the file system instead of mounted to a drive letter) and its belonging physical disk drive(s) with WMI? For example I have got a volume mountpoint on a W2K8 server which is mounted to “C:\Data\” and the mountpoint is spreaded on the physical disk drives 2, 4, and 5 of the server (the Data Management of the Server Manager shows that) but I cannot find a way to get this to know by using WMI. Volumes which have got a drive letter can be connected with the WMI-Classes Win32_DiskDrive -- Win32_DiskDriveToDiskPartition -- Win32_DiskPartition -- Win32_LogicalDiskToPartition -- Win32_LogicalDisk – but the problem is, that volume mountpoints aren’t listed in the class Win32_LogicalDisk, they are only listed in Win32_Volume. And I did not find a way to connect the class Win32_Volume with the class Win32_DiskDrive – there are missing some linking classes. Does anyone know a solution?

    Read the article

  • How does the linux kernel manage less than 1GB physical memory ?

    - by TheLoneJoker
    I'm learning the linux kernel internals and while reading "Understanding Linux Kernel", quite a few memory related questions struck me. One of them is, how the Linux kernel handles the memory mapping if the physical memory of say only 512 MB is installed on my system. As I read, kernel maps 0(or 16) MB-896MB physical RAM into 0xC0000000 linear address and can directly address it. So, in the above described case where I only have 512 MB: How can the kernel map 896 MB from only 512 MB ? What about user mode processes in this situation? Where are user mode processes in phys RAM? Every article explains only the situation, when you've installed 4 GB of memory and the kernel maps the 1 GB into kernel space and user processes uses the remaining amount of RAM. I would appreciate any help in improving my understanding. Thanks..!

    Read the article

  • Is it possible to define a virtual directory in IIS and make the files relative to the physical dire

    - by Mikey John
    Is it possible to define a virtual directory in IIS and somehow make the files in that directory relative to the physical directory and not to the virtual directory ? For instance on my server I have the following folders: D:\WebSite\Css\myTheme.css, D:\WebSite\Images\image1.jpg I created a virtual directory on IIS resources.mysite: Inside my website I reference the sheet like this resources.mysite/myTheme.css But inside myTheme.css I reference pictures from ../Images/images1.jpg. So the problem is that image1.jpg is not found because it is relative to the physical folder and not the virtual folder on IIS. Can I solve this problem without modifying the style sheet ?

    Read the article

  • Create a Stream without having a physical file to create from.

    - by jhorton
    I'm needing to create a zip file containing documents that exist on the server. I am using the .Net Package class to do so, and to create a new Package (which is the zip file) I have to have either a path to a physical file or a stream. I am trying to not create an actual file that would be the zip file, instead just create a stream that would exist in memory or something. My question is how do you instantiate a new Stream (i.e. FileStream, MemoryStream, etc) without having a physical file to instantiate from.

    Read the article

  • Import module stored in a cStringIO data structure vs. physical disk file

    - by Malcolm
    Is there a way to import a Python module stored in a cStringIO data structure vs. physical disk file? It looks like "imp.load_compiled(name, pathname[, file])" is what I need, but the description of this method (and similar methods) has the following disclaimer: Quote: "The file argument is the byte-compiled code file, open for reading in binary mode, from the beginning. It must currently be a real file object, not a user-defined class emulating a file." [1] I tried using a cStringIO object vs. a real file object, but the help documentation is correct - only a real file object can be used. Any ideas on why these modules would impose such a restriction or is this just an historical artifact? Are there any techniques I can use to avoid this physical file requirement? Thanks, Malcolm [1] http://docs.python.org/library/imp.html#imp.load_module

    Read the article

< Previous Page | 32 33 34 35 36 37 38 39 40 41 42 43  | Next Page >