Search Results

Search found 24382 results on 976 pages for 'tutor process procedure f'.

Page 372/976 | < Previous Page | 368 369 370 371 372 373 374 375 376 377 378 379  | Next Page >

  • Windows 8 Secureboot: How do you bootup from another device such as cd/dvd drive or usb flash etc.?

    - by Victor T.
    On PC's and laptops running an older OS, this is just a simple matter of going into the BIOS and setting the boot sequence and putting the boot cd/dvd in the drive. In many cases you can even just hit one of the F* function keys to bring up the boot sequence menu on-the-fly during POST. The main problem I'm running into is that other devices besides the primary HD is disabled when SecureBoot is enabled. So far the only way I've gotten it to work is to disable SecureBoot and enable something called legacy mode. Needless to say this make it difficult to boot things like OS recovery tools, PartitionHD backups, Linux LiveCD's and a bunch of others. Is there another procedure for doing this since it seems to mess up the Windows 8 install? By mess up I mean that after re-enabling SecureBoot and starting Windows 8 normally, the OS goes into a 'preping repair phase' for some reason that takes forever to complete before getting into a usable desktop.

    Read the article

  • Can I replace my notebook's fan without replacing the heat sink?

    - by kuzzooroo
    My laptop (Acer Travelmate 8204) has started making a grinding noise, which seems to be coming from the fan (not the hard drive). Some articles online mention replacing the fan, but others imply that one should replace both the fan and the heat sink. Does it make sense to replace the fan only? (addendum: does this procedure really take 3 hours for a noob, as this video implies? UPDATE: the fan certainly seems to be on the "top" layer when I open my laptop but some parts of it extend under other layers) Some additional info in response to comments: I have run MS scandisk on the hard drive a few times since the grinding started. It usually reports finding something or other but the computer's behavior doesn't change I'm pretty sure it's the fan based on where the noise is coming from. I employed the cardboard tube trick from the PC World article.

    Read the article

  • Problem, executing commands in cmd using c#

    - by srk
    I need to execute the below command in command prompt. C:\MySQL\MySQL Server 5.0\bin>mysql -uroot -ppassword < d:/admindb/aar.sql When i do this manually in cmd, i am getting my results. Now i am trying to do this programatically, to execute it in cmd from c# code. I am using the below code to do it. I am not getting any errors and Result !!! When i debug, i get the value of string commandLine as below, "\"C:\\MySQL\\MySQL Server 5.0\\bin\\\" -uroot -ppassword > \"D:/admindb/AAR12.sql" I guess the problem is with this string, passed to cmd. How to solve this ??. public void Execute() { string commandLine = "\"" + MySqlCommandPath + "\"" + " -u" + DbUid + " -p" + DbPwd + " > " + "\"" + Path.Combine(Path_Backup, FileName_Backup + ExcID + ".sql"); System.Diagnostics.ProcessStartInfo PSI = new System.Diagnostics.ProcessStartInfo("cmd.exe"); PSI.RedirectStandardInput = true; PSI.RedirectStandardOutput = true; PSI.RedirectStandardError = true; PSI.UseShellExecute = false; System.Diagnostics.Process p = System.Diagnostics.Process.Start(PSI); System.IO.StreamWriter SW = p.StandardInput; System.IO.StreamReader SR = p.StandardOutput; SW.WriteLine(commandLine); SW.Close(); }

    Read the article

  • Sync two SqlExpress using NHibernate

    - by Christian
    Hello, I am creating a simple project management system which uses NHibernate for object storage. The underlying database is SQL express (at least currently for development). The client runs on either the desktop or laptop. I know I could use web-services and store the DB only on the desktop, but this would force the desktop to be available all the time. I am currently thinking about duplicating the DB, having two instances with "different data". To clarify, we are not talking about a productive app here, its a prototype. One way to achieve this very simple would be the following process: Client: Check if desktop DB is available (through web service) Client: If yes, use desktop storage, no problem here Client: If not, use own DB as storage Client: Poll desktop regulary, as soon as it comes on, sync Client: Switch to desktop storage ... Desktop: Do not attempt any DB operation before checking for required sync Desktop: If sync needed, do it... My question is now, how would you sync? Assume 4 or 5 types of objects, all have GUID as identifiers. Would you always manually "lazy load" all objects of a certain type and feed them to the DB. Would you always drop the whole desktop DB in case the client DB may be newer and out of sync? Again, I want to stress out, I am not assuming any conflicts or stale data, I basically just want to "copy the whole DB from the client". Would you use NHibernate for this? Or would you separate the copy process? When I think about it, my questions comes down to this: Is there any function from NHibernate: SyncDBs_SourceWins_(SourceDB, TargetDB) Thanks for help, Chris

    Read the article

  • getting an exception when refreshing the configuration in memory on change to external config file

    - by RKP
    Hi, I have a windows service which reads the config settings from an external file which is located at a different path than the path to the executable for the windows service. the windows service uses a FileSystemWatcher to monitor the changes to the external config file and when it the config file is changed, it should refresh the settings in memory by reading the updated settings from the config file. but this is where I am getting an exception "ConfigurationErrorsException" and the message is "An error occurred creating the configuration section handler for appSettings: The process cannot access the file 'M:\somefolder\WindowsService1.Config' because it is being used by another process." and the inner exception is actually "IOException" with same message. here is the code. I am not sure what is wrong with the code. Please help. protected void watcher_Changed(object sender, FileSystemEventArgs e) { ConfigurationManager.RefreshSection(ConfigSectionName); WriteToEventLog(ConfigKeyCheck); if (FileChanged != null) FileChanged(this, EventArgs.Empty); } private void WriteToEventLog(string key) { if (EventLog.SourceExists(ServiceEventSource)) { EventLog.WriteEntry(ServiceEventSource, string.Format("key:{0}, value:{1}", key, ConfigurationManager.AppSettings[key])); } }

    Read the article

  • Low Level Console Input

    - by Soulseekah
    I'm trying to send commands to to the input of a cmd.exe application using the low level read/write console functions. I have no trouble reading the text (scraping) using the ReadConsole...() and WriteConsole() functions after having attached to the process console, but I've not figured out how to write for example "dir" and have the console interpret it as a sent command. Here's a bit of my code: CreateProcess(NULL, "cmd.exe", NULL, NULL, FALSE, CREATE_NEW_CONSOLE, NULL, NULL, &si, &pi); AttachConsole(pi.dwProcessId); strcpy(buffer, "dir"); WriteConsole(GetStdHandle(STD_INPUT_HANDLE), buffer, strlen(buffer), &charRead, NULL); STARTUPINFO attributes of the process are all set to zero, except, of course, the .cb attribute. Nothing changes on the screen, however I'm getting an Error 6: Invalid Handle returned from WriteConsole to STD_INPUT_HANDLE. If I write to (STD_OUTPUT_HANDLE) I do get my dir written on the screen, but nothing of course happens. I'm guessing SetConsoleMode() might be of help, but I've tried many mode combinations, nothing helped. I've also created a quick console application that waits for input (scanf()) and echoes back whatever goes in, didn't work. I've also tried typing into the scanf() promp and then peek into the input buffer using PeekConsoleInput(), returns 0, but the INPUT_RECORD array is empty. I'm aware that there is another way around this using WriteConsoleInput() to directly inject INPUT_RECORD structured events into the console, but this would be way too long, I'll have to send each keypress into it. I hope the question is clear. Please let me know if you need any further information. Thanks for your help.

    Read the article

  • How to generate new CSRs for TLS use in sendmail?

    - by Mikey B
    SendMail 8.13.8 | CentOS 5.x Hi Guys, I'm using ca-signed TLS certificates on my sendmail server and they are up for renewal soon. Our new CA doesn't like our old CSR so I need to generate a new CSR. Can someone point me to the procedure for doing this (without affecting the production certs that are already in use)? I'm paranoid of overwriting the old TLS certs in the process of generating a CSR. Most of the instructions I've found are for implementing self-signed TLS certs -- which isn't an option for me at this time. I'm thinking it would something like: openssl req -new -nodes -out new-tls.csr -keyout new-tls-private.key But I wasn't sure if I was missing some options there such as the -x509 option... -M

    Read the article

  • Mysql refusing connection: a very special connection issue

    - by k to the z
    I have my programers remoting into a web server with windows rdp. This web server is the only machine that can access another mysql server in a secure zone. When I remote into the web server from my machine I am able to connect to the mysql server through the mysql workbench on the web server. However, when I try this same procedure from another person's computer I can get into the server via rdp. I just can't connect to mysql using the workbench. I have checked and re checked the credentials and connection information. They match. I've had other people check and re check the credentials. As far as mysql permissions are concerned this user is allowed to connect from any machine. Plus I'm remoting into the same web server. The only difference seems to be which computer is remoting into the webserver. wtf?

    Read the article

  • Need a piece of advice about e-mail automation in ms exchange + ms office environment

    - by be here now
    Hi, guys. I need your help in the following simple situation. I've got an MS Exchange server and some client computers running on XP with Office 2003 installed. And I've got a process I need to automate. Twice a day a known list of people sends an e-mail to a certain mailbox (let's call it manager's mailbox) - basically, an accomplishment report. After recieving letters from all of these people the mailbox owner sends and e-mail to another mailbox, meaning that a certain process is done. What I need to do is to replace this manager's mailbox with a depersonalized mailbox that will accumulate all the reports and automatically send a message after collecting all of them. I am definitely not in a "oh my God, what shold I do?" situation, and currently my imagination shows me a couple of ways to solve this problem, which I'm going to try, and I'm not ascking for a ready solution. But since I'm not experienced in Office/VBA developement, I'd like to ask a corresponding pro's opinion. Can you point me to a right direction from the best practices' point of view?

    Read the article

  • Resources for setting up a Visual Studio/C++ development environment

    - by Tom H.
    I haven't done much "front-end" development in about 15 years since moving to database development. I'm planning to start work on a personal project using C++ and since I already have MSDN I'll probably end up doing it in Visual Studio 2010. I'm thinking about using Subversion as a version control system eventually. Of course, I'd like to get up and running as quickly as I can, but I'd also like to avoid any pitfalls from a poorly organized project environment. So, my question is, are there any good resources with common best practices for setting up a development environment? I'm thinking along the lines of where to break down a solution into multiple projects if necessary, how to set up a unit testing process, organizing resources, directories, etc. Are there any great add-ons that I should make sure I have set up from the start? Most tutorials just have one simple project, type in your code and click on build to see that your new application says, "Hello World!". This will be a Windows application with several DLLs as well (no web development), so there doesn't need to be a deploy to a web server kind of process. Mostly I just want to make sure that I don't miss anything big and then have to extensively refactor because of it. Thanks!

    Read the article

  • How to create a new text file in DOS with the end result allowing me to rename the file?

    - by Rolo
    I would like an exact duplicate of the following procedure on a Windows computer using mouse clicks: Right Click in a directory and choose New and then Text Document. When one does this, the text file is created with a default name of New Text Document AND it is also highlighted so that I can type in my own file name. I would like to do this in DOS. I don't care what file name is originally created. What I want is for the name of the file to automatically be highlighted / able to be renamed, so that I can rename it. How can DOS execute / simulate a rename command / an F2 being pressed on the keyboard to a file that it has just created?

    Read the article

  • C++. How to define template parameter of type T for class A when class T needs a type A template parameter?

    - by jaybny
    Executor class has template of type P and it takes a P object in constructor. Algo class has a template E and also has a static variable of type E. Processor class has template T and a collection of Ts. Question how can I define Executor< Processor<Algo> > and Algo<Executor> ? Is this possible? I see no way to defining this, its kind of an "infinite recursive template argument" See code. template <class T> class Processor { map<string,T> ts; void Process(string str, int i) { ts[str].Do(i); } } template <class P> class Executor { Proc &p; Executor(P &p) : Proc(p) {} void Foo(string str, int i) { p.Process(str,i); } Execute(string str) { } } template <class E> class Algo { static E e; void Do(int i) {} void Foo() { e.Execute("xxx"); } } main () { typedef Processor<Algo> PALGO; // invalid typedef Executor<PALGO> EPALGO; typedef Algo<EPALGO> AEPALGO; Executor<PALGO> executor(PALGO()); AEPALGO::E = executor; }

    Read the article

  • Probelem, executing commands in cmd using c#

    - by srk
    I need to execute the below command in command prompt. C:\MySQL\MySQL Server 5.0\bin>mysql -uroot -ppassword < d:/admindb/aar.sql When i do this manually in cmd, i am getting my results. Now i am trying to do this programatically, to execute it in cmd from c# code. I am using the below code to do it. I am not getting any errors and Result !!! When i debug, i get the value of string commandLine as below, "\"C:\\MySQL\\MySQL Server 5.0\\bin\\\" -uroot -ppassword > \"D:/admindb/AAR12.sql" I guess the problem is with this string, passed to cmd. How to solve this ??. public void Execute() { string commandLine = "\"" + MySqlCommandPath + "\"" + " -u" + DbUid + " -p" + DbPwd + " > " + "\"" + Path.Combine(Path_Backup, FileName_Backup + ExcID + ".sql"); System.Diagnostics.ProcessStartInfo PSI = new System.Diagnostics.ProcessStartInfo("cmd.exe"); PSI.RedirectStandardInput = true; PSI.RedirectStandardOutput = true; PSI.RedirectStandardError = true; PSI.UseShellExecute = false; System.Diagnostics.Process p = System.Diagnostics.Process.Start(PSI); System.IO.StreamWriter SW = p.StandardInput; System.IO.StreamReader SR = p.StandardOutput; SW.WriteLine(commandLine); SW.Close(); }

    Read the article

  • implementing a Intelligent File Transfer Software in java over TCP/IP

    - by whyjava
    Hello I am working on a proposal where we have to implement a software which can move files between one source to destination.The overall goal of this project is to create intelligent file transfer.This software will have three components :- 1) Broker : Broker is the module that communicates with other brokers, monitors files, moves files, retrieves configurations from the Configuration Manager, supplies process information for the monitor, archives files, writes all process data to log files and escalates issues if necessary 2) Configuration Manager :Configuration Manager is a web-based application used to configure and deploy the configuration to all brokers. 3) Monitor : Monitor is a web-based application used to monitor each Broker in the environment. This project has to be built up in java and protocol for file transfer in tcp/ip. Client does not want to use FTP. File Transfer seems very easy, until there are several processes who are waiting to pick the file up automatically. Several problems arise: How can we guarantee the file is received at the destination? If a file isn’t received the first time, we should try it again (even after a restart or power breakdown) ? How does the receiver knows the file that is received is complete? How can we transfer multiple files synchronously? How can we protect the bandwidth, so file transfer isn’t blocking other processes? How does one interoperate between multiple OS platforms? What about authentication? How can we monitor het workflow? Auditing / logging Archiving Can you please provide answer to some of these? Thanks

    Read the article

  • Automatically restarting Erlang applications

    - by Nick
    I recently ran into a bug where an entire Erlang application died, yielding a log message that looked like this: =INFO REPORT==== 11-Jun-2010::11:07:25 === application: myapp exited: shutdown type: temporary I have no idea what triggered this shutdown, but the real problem I have is that it didn't restart itself. Instead, the now-empty Erlang VM just sat there doing nothing. Now, from the research I've done, it looks like there are other "start types" you can give an application: 'transient' and 'permanent'. If I start a Supervisor within an application, I can tell it to make a particular process transient or permanent, and it will automatically restart it for me. However, according to the documentation, if I make an application transient or permanent, it doesn't restart it when it dies, but rather it kills all the other applications as well. What I really want to do is somehow tell the Erlang VM that a particular application should always be running, and if it goes down, restart it. Is this possible to do? (I'm not talking about implementing a supervisor on top of my application, because then it's a catch 22: what if my supervisor process crashes? I'm looking for some sort of API or setting that I can use to have Erlang monitor and restart my application for me.) Thanks!

    Read the article

  • Best Functional Approach

    - by dbyrne
    I have some mutable scala code that I am trying to rewrite in a more functional style. It is a fairly intricate piece of code, so I am trying to refactor it in pieces. My first thought was this: def iterate(count:Int,d:MyComplexType) = { //Generate next value n //Process n causing some side effects return iterate(count - 1, n) } This didn't seem functional at all to me, since I still have side effects mixed throughout my code. My second thought was this: def generateStream(d:MyComplexType):Stream[MyComplexType] = { //Generate next value n return Stream.cons(n, generateStream(n)) } for (n <- generateStream(initialValue).take(2000000)) { //process n causing some side effects } This seemed like a better solution to me, because at least I've isolated my functional value-generation code from the mutable value-processing code. However, this is much less memory efficient because I am generating a large list that I don't really need to store. This leaves me with 3 choices: Write a tail-recursive function, bite the bullet and refactor the value-processing code Use a lazy list. This is not a memory sensitive app (although it is performance sensitive) Come up with a new approach. I guess what I really want is a lazily evaluated sequence where I can discard the values after I've processed them. Any suggestions?

    Read the article

  • How can I send raw postscript to a remote printer via CUPS?

    - by Ash
    I have an ancient fax device with a printer interface that only accepts postscript level 1 documents formatted in a specific way. I only have access to this printer over the lpd:// protocol. I have some old documents from our previous system that work fine on our Unix machines, but they are altered somehow by CUPS when I use lp on our Linux system. The PDF files that end up in the print queue are significantly modified versions of the original, and although they still render in ghostscript, they don't do anything on the printer. I'm wondering if there's a way to tell CUPS "don't process this, just send it to the printer without modification", or whether there's a lpd client or procedure I could try?

    Read the article

  • The same C# code produces different output in Visio Professional and Premium

    - by user615993
    I have built a simple conversion Add In, but its behavior is unfortunately different with the different Visio Editions (Visio 2010 Professional and Visio 2010 Premium). The Add In takes a Process-Diagram created with Shapes from Stencil_1.vss and creates a new slightly different Process-Diagram with Shapes from Stencil_2.vsd. It loops through a Visio page and for each shape founded creates a new shapes from new master shape (from Stencil_2.vsd) and drop it into the new page. Geometry, captions etc. are the same, only the shape-appearance is changed. Below is the source diagram: When I run the code into Visio 2010 Professional the swimlane shapes are drawn correctly. When I run the same code from Visio Premium the swimlane appearance and layout are mismatched: Both times i drop the SAME Shape("Swimlane" from the same stencil) into the Page with the SAME Code fragment: Visio.Master vm = swimlane_stencil.Masters.get_ItemU(@"Swimlane"); Visio.Shape TargetShape = targetPage.Drop(vm, shape_x, shape_y); How could I ensure, that the code produces any time the same (correct) output? Must I disable any (premium)features in the swimlane-shapesheet?

    Read the article

  • Installing Oracle11gr2 on redhat linux

    - by KItis
    I have basic question about installing applications on linux operating system. i am going to express my issue considering oracle db installation as a example. when installing oracle database , i created a user group called dba and and user in this group called ora112. so this users is allowed to install database. so my question is if ora112 uses umaks is set to 077, then no other uses will be able to configure oracle database. why do we need to follow this practice. is it a accepted procedure in application installation on Linux. please share your experience with me. thanks in advance for looking into this issue say i install java application on this way. then no other application which belongs to different user account won't be able use java running on this computer because of this access restriction.

    Read the article

  • Is it possible to detect that a database connection is to a copy rather than to the original database?

    - by user149238
    I have an application that needs to know if it is connected to the original database that it was installed with or if the connection is to a copy of that database. Is there any known method to know if the database has been cloned and the application is no longer connected to the original? I am specifically interested in MS SQL Server and Oracle. I was kicking ideas around for a stored procedure but that most likely doesn't have access to the hardware to confirm unique hardware information that would somewhat guarantee that the database is the one that it was originally connected to during installation. I'm trying to prevent/detect cloning of a database so that there is only 1 "true location of truth". Thanks!

    Read the article

  • Safari specific scroll bar issue in legacy code

    - by user1237169
    I am trying to debug an issue that is occurring specifically in Safari. On a few pages of a web application, the content is larger than the frame and a scroll bar appears on the right but when the scroll bar moves up or down the content does not scroll with it. So you can "scroll" the scroll bar but the content itself was inaccessible even though the scroll bar was mobile. The issue only occurs in the "Multi-Process Windows" debug mode option but not in the "Single-Process Windows" option. The scroll bar works perfectly fine in Firefox, IE, and Chrome, just not in Safari. Because there's a lot of legacy code, I'm not quite sure exactly what the actual content is and which specific html elements are relevant. From what I can tell there's an Iframe element, html element, body element, div element, iframe element html element, body element and finally some divs. edit Does it matter if some of the elements within the <iframe> have the attribute scrolling="no"? I see this on a few of the elements within iframe but my coworker reassures me they don't matter.

    Read the article

  • Mixing menuItem.setIntent with onOptionsItemSelected doesn't work

    - by superjos
    While extending a sample Android activity that fires some other activities from its menu, I came to have some menu items handled within onOptionsItemSelected, and some menu items (that just fired intents) handled by calling setIntent within onCreateOptionsMenu. Basically something like: @Override public boolean onCreateOptionsMenu(Menu menu) { super.onCreateOptionsMenu(menu); menu.add(0, MENU_ID_1, Menu.NONE, R.string.menu_text_1); menu.add(0, MENU_ID_2, Menu.NONE, R.string.menu_text_2); menu.add(0, MENU_ID_3, Menu.NONE, R.string.menu_text_3). setIntent(new Intent(this, MyActivity_3.class)); return true; } @Override public boolean onOptionsItemSelected(MenuItem item) { super.onOptionsItemSelected(item); switch (item.getItemId()) { case (MENU_ID_1): // Process menu command 1 ... return true; case (MENU_ID_2): // Process menu command 2 ... // E.g. also fire Intent for MyActivity_2 return true; default: return false; } } Apparently, in this situation the Intent set on MENU_ID_3 is never fired, or anyway the related activity is never started. Android javadoc at some point goes like <<[if you set an intent on a menu item] and nothing else handles the item, then the default behavior will be to [start the activity with the intent]. What does it actually mean "and nothing else handles the item"? Is it enough to return false from onOptionsItemSelected? I also tried not to call super.onOptionsItemSelected(item) at the beginning and only invoke it in the default switch case, but I had same results. Does anyone have any suggestion? Does Android allow to mix the two type of handling? Thanks for your time everyone.

    Read the article

  • Second virtual host on Apache redirects to root

    - by Slytherin
    I tried to setup my second virtual host , but I'm getting the default /var/www/index.html ( the one that says "It works!" ) I followed the same procedure as the first time, but this time it didn't work my configuration looks like this <VirtualHost *:80> ServerName messup ServerAlias messup.loc ServerAdmin webmaster@localhost DocumentRoot /var/www/messup ErrorLog ${APACHE_LOG_DIR}/error.log CustomLog ${APACHE_LOG_DIR}/access.log combined </VirtualHost> my hosts configuration is the following 127.0.0.1 localhost 127.0.1.1 SlytherinPC 127.0.0.1 AFS.loc 127.0.0.1 messup.loc After this , my apache wouldn't restart without any message , only saying [fail] , but stop and start worked. What am I missing ?

    Read the article

  • reporting tool/viewer for large datasets

    - by FrustratedWithFormsDesigner
    I have a data processing system that generates very large reports on the data it processes. By "large" I mean that a "small" execution of this system produces about 30 MB of reporting data when dumped into a CSV file and a large dataset is about 130-150 MB (I'm sure someone out there has a bigger idea of "large" but that's not the point... ;) Excel has the ideal interface for the report consumers in the form of its Data Lists: users can filter and segment the data on-the-fly to see the specific details that they are interested in - they can also add notes and markup to the reports, create charts, graphs, etc... They know how to do all this and it's much easier to let them do it if we just give them the data. Excel was great for the small test datasets, but it cannot handle these large ones. Does anyone know of a tool that can provide a similar interface as Excel data lists, but that can handle much larger files? The next tool I tried was MS Access, and found that the Access file bloats hugely (30 MB input file leads to about 70 MB Access file, and when I open the file, run a report and close it the file's at 120-150 MB!), the import process is slow and very manual (currently, the CSV files are created by the same plsql script that runs the main process so there's next to no intervention on my part). I also tried an Access database with linked tables to the database tables that store the report data and that was many times slower (for some reason, sqlplus could query and generate the report file in a minute or soe while Access would take anywhere from 2-5 minutes for the same data) (If it helps, the data processing system is written in PL/SQL and runs on Oracle 10g.)

    Read the article

  • Locale number formatting issue windows 2008

    - by kris
    On a project we have multiple servers running windows 2008. The servers are using the Russian locale. We have several programs that use floating point numbers but the fractional part of the number on SOME servers is getting truncated. Through the regional settings each machine has: Locale: Russian Current Location: United States Decimal Symbol: . (period) I've tried distributing the changes through "Copy Settings" and even though the procedure works it seems like the settings aren't actually being propagated. So next I went into the registry. There is a key called "sDecimal" and in all cases on all servers the value in the key is '.' There is no difference that I can find between the servers that DO have correct decimal formatting and DO NOT. Any advice on where I can look for a problem like this?

    Read the article

< Previous Page | 368 369 370 371 372 373 374 375 376 377 378 379  | Next Page >