Search Results

Search found 11003 results on 441 pages for 'usb storage'.

Page 377/441 | < Previous Page | 373 374 375 376 377 378 379 380 381 382 383 384  | Next Page >

  • LSI RAID monitor reports "Consistency Check inconsistency logging disabled"

    - by carlpett
    I have a server with a LSI MegaRAID 9261-8i controller. Recently I started getting alerts like this one: Controller ID: 1 Consistency Check inconsistency logging disabled, too many inconsistencies on VD: 0 Generated on:Sat May 12 04:06:40 2012 SYSTEM DETAILS--- IP Address: 192.168.1.29 OS Name: Windows 7 x64 OS Version: 6.01 Driver Name: megasas.sys Driver Version: 4.5.1.64 IMAGE DETAILS--- BIOS Version: 2.120.33-1197 Firmware Package Version: 12.12.0-0045 Firmware Version: 3.21.00_4.11.05.00_0x05000000 VD 0 is a RAID mirror containing the system disk. I have searched and read, but cannot find any trace of how to actually do anything about this. I tried running a scandisk but that did not find anything (as I expected, since scandisk reads the disks as exposed by the controller, right?). The MegaRAID Storage Manager does not as far as I can see have any options for checking or fixing physical disks. The program claims the VD is "healty", and both disks have Error count 0. Also a bit strange is the System details in the message... The IP address is associated with the RAS (dial in) interface, and the OS should be Windows Server 2011 SBS. Has anyone else experienced this before? What can be done?

    Read the article

  • Reinstall Acer OEM Windows 8, Windows 8 Recovery for Acer Aspire V5 122p

    - by stwindr
    My Acer Aspire V5-122P-61456G50NSS, model - MS2377, has crashed all together. It came preloaded with Windows 8 and I upgraded to windows 8.1 3-4 days before crash. Unfortunately I did not make any recovery media before the crash. While accessing the eRecovery on Acer store with my PC's serial no. it says nor RCD available for this. I tried recovery by loading recovery manager (Left Alt + F10) Various other advanced startup options (like holding shift key while turning on or pressing F8 key) returns nothing but no luck. However I am able to enter BIOS. After doing research on above condition on various PC forums, now my questions: I read that a 'Windows Recovery Drive' can be made on any PC running Windows 8 and could be used to repair another PC. Does anybody in SuperUser community have that (or a link to download the same from somewhere? as I'm unable to find anybody running windows 8 among my friends). I downloaded a window 8 Pro ISO and made a bootable USB. I was able to go to 'Repair Your Computer' option and after going to 'Reset your PC' option found that my recovery partition has gone/missing. I tried all options available but no luck. Then I tried to install with that Windows 8 Pro ISO but got message: "The product key entered does not match any of the Windows images available for installation. Enter a different product key". before this message I did not got any form to fill product key! Does this mean that the installer was picking up the key from BIOS (OEM Key)? and may be the installation did not succeeded because OEM Windows version was Window 8 and I was trying to install Windows 8 Pro. If that is the case then, could somebody please send me link to download an Windows 8 ISO? I am helpless and couldn't find anywhere on internet (without having to pay for a new key, but I should not pay as the installer will use OEM key).

    Read the article

  • virtualbox installing iso Error "could not find a valid v7 on sda"

    - by MountainX
    I decided to try this suggestion to install Android x86 on Virtual Box. I'm following those steps and I'm at #4. I used the android-x86-4.0-RC1-amd_brazos.iso (because I have a ThinkPad that this might be compatible with and it seemed as good as any of the other choices...) I'm getting an endless series of errors: .[numbers] VFS: could not find a valid v7 on sda. .[numbers] VFS: could not find a valid v7 on sda. repeating... For storage, I made a VDI image sized at 4.0 GB (dynamically allocated) attached on SATA Port 0. Background and more details: I'm running Kubuntu 12.04. I installed VirtualBox 4.1.12 after adding deb http://download.virtualbox.org/virtualbox/debian precise contrib to my sources. EDIT: Now I'm wondering if I installed the right package. I verified that I'm running 4.1.12. But I installed it with apt-get install virtualbox instead of the recommended apt-get install virtualbox-4.1. I checked just now and see this: apt-cache search virtualbox virtualbox - x86 virtualization solution - base binaries virtualbox-4.1 - Oracle VM VirtualBox But when I run VirtualBox, I get the Oracle VM VirtualBox Manager version 4.1.12, so I think I'm OK. I did see one minor issue (possibly related to this question) when installing VB, but in my case I don't think it is actually an error at all: * No suitable module for running kernel found [fail] invoke-rc.d: initscript virtualbox, action "restart" failed. VirtualBox installed and seems to be running fine. I just can't get the ISO image to install. The error is as shown above.

    Read the article

  • TSM Backup Fails with VSS

    - by user176320
    Since we rebuilt our servers to windows servers 2008 x64 r2 we have perpetual problems with scheduled backup (shadow copy). In the Application event log, the following events are logged on both nodes: The description for Event ID 4112 from source TsmVssPlugin cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer. If the event originated on another computer, the display information had to be saved with the event. The following information was included with the event: VSS processing encountered error 'VSS_E_UNEXPECTED_PROVIDER_ERROR' in the Volume Shadow Copy API 'AddToSnapshotSet'. For more information, see the IBM Tivoli Storage Manager client error log. Re installing TSM didn't change anything and still logging same events. TSM Error log file shows following: ANS1327W The snapshot operation for 'C:' failed with error code: -1. ANS5250E An unexpected error was encountered. TSM function name : BaStartSnapshot TSM function : initializeSnapshotSet() failed, check Microsoft Application event log for VSS errors TSM return code : -1

    Read the article

  • HP P212 hangs on Initializing

    - by user927586
    I'm in trouble... Server: HP Microserver N36L Storage: HP P212/256 with BBWC Drives: 4 WD 2 Tb While expanding the RAID 5 array from 3 to 4 drives, the server rebooted itself. Expansion was at 76%. Now at boot the P212 seems to hang on initializing. After some time screen resets and the server boots, but in the os (Windows Server 2008R2) the P212 has errors (error code 10) and it's not seen by the HP ACU. Whats' going on? It's trying to complete the expansion? It's trying to make all over the expansion? It's simply stuck? What should I do? I NEED the data on the array! PS In the server BIOS, on the hd boot priority, the server still reports the array logical drive... maybe it's a good sign... PPS I'm not at the server physical location, so I cannot tell if the drives in the array are being accessed (that would be the case if the controller it's redoing/completing the expansion process) or not right now. Bye Dario

    Read the article

  • "0x80004005: Unspecified error" when renaming folders in Windows 7

    - by Michael Steele
    Setup I've just installed Windows 7 Ultimate 64bit. The operating system is installed on an 80GB Intel X-25M. I have a secondary 500GB Barracuda 7200.12 to be used for storage. This second drive is mounted as 'G'. Problem I'm getting an error whenever I try to rename a folder within this drive. The error says: An unexpected error is keeping you from renaming the folder. If you continue to receive this error, you can use the error code to search for help with this problem. Error 0x80004005: Unspecified error Clicking the "Try Again" button gets past the error, and correctly renames the folder. If I create a folder and leave it's name as "New Folder", then I don't see an error. I'm also able to manipulate files however I want without seeing an error. Things I've Tried Changing permissions on the drive Reformatting the drive. I've tried using both a "Basic" and "Dynamic" partition table. Checking the drive for errors using Microsoft tools Things I've Not Yet Tried When I first installed Windows I was given a choice between three types of partitions to use. I no longer remember what the choices were or what I selected. One was a GUID partition table, one was a traditional MBR, and I can't remember the third option.

    Read the article

  • multiple monitor, ATI EyeFinity vs NVidia Mosaic on HDMI

    - by user1531897
    i have been googling much for answer but only someone with real experience can help here. my aim is to have 5 monitors connected to one computer in 2x2 full screen on all 4 monitors (video wall) with same resolution, 4xfullHD for example, plus one -5th monitor as controling. Ati have example picture of this configuration here. I have no gaming nor 3d needs here. Simple desktop applications plus video streams. So because graphic cards for this are expensive, i need to find out before buying pros and cons of 2 possible solutions (1) Ati Eyefinity capable card(s) ...and (2) Nvidia Quadro/NVS card(s) with mosaic and/or nvidia surround technology. For example i can find that current good cards for this can be: Ati's 7870 eyefinity6 card, link here pros: one card can handle all 5 displays, cons: active DP adapters needed (sometimes with aditional usb-powering complication) Nvidia Qudro NVS 450, link here Both cards have DisplayPorts as outputs (my targets are HDMI displays), but as far i saw information is that Eyefinity needs "active DP-DVI/hdmi adapters" for outputs and they are little expensive...? Does nvidia have this limitation (active adapters) ??? And final question, is Ati Eyefinity still better for this purpose than Nvidia-mosaic by someone's real experience there.

    Read the article

  • What is my miniport's service name?

    - by Ian Boyd
    i am trying to query the physical sector size of my drive using fsutil: C:\Windows\system32>fsutil fsinfo ntfsinfo c: NTFS Volume Serial Number : 0x78cc11b2cc116c1e Version : 3.1 Number Sectors : 0x000000003a382fff Total Clusters : 0x00000000074705ff Free Clusters : 0x00000000022fc29b Total Reserved : 0x00000000000007d0 Bytes Per Sector : 512 Bytes Per Physical Sector : <Not Supported> Bytes Per Cluster : 4096 Bytes Per FileRecord Segment : 1024 Clusters Per FileRecord Segment : 0 Mft Valid Data Length : 0x00000000305c0000 Mft Start Lcn : 0x00000000000c0000 Mft2 Start Lcn : 0x0000000003a382ff Mft Zone Start : 0x0000000006951940 Mft Zone End : 0x0000000006951c80 RM Identifier: 19B22CBE-570D-19DE-9C72-CD758F800DDC You can see that the Bytes Per Physical Sector value is Not Supported: Bytes Per Physical Sector : <Not Supported> In KB Article Microsoft support policy for 4K sector hard drives in Windows, Microsoft says: If fsutil.exe continues to display "Bytes Per Physical Sector : " after you apply the latest storage driver and the required hotfixes, make sure that the following registry path exists: HKLM\CurrentControlSet\Services\<miniport’s service name>\Parameters\Device\ Name: EnableQueryAccessAlignment Type: REG_DWORD Value: 1: Enable The only thing i don't know is what my Miniport's service name is. What is my miniport's service name. i know that my SATA drives are in AHCI mode, and AHCI uses the msahci driver service: Is that my miniport service? "MSAHCI"? See also Hitachi - Advanced Format Technology Brief RMPrepUSB - Advanced Format (4K sector) hard disks Microsoft support policy for 4K sector hard drives in Windows OSR Online - Advance Disk Format support in Storport Virtual Mniport diver Default cluster size for NTFS, FAT, and exFAT Wikipedia - Advanced Format

    Read the article

  • HP DL160G6 bios update fails

    - by Bojo
    I tried to update the BIOS from my HP DL160G6's. Unfortunately the Windows update degraded my BIOS version from 243 to 237. But when I try to upgrade both servers to version the update fails. First I got a warning like: CMOS Layout difference between System ROM and ROM file has detected. AFU recommand (sic) adding /C commands of your original input commands. Press "A" to accept AFU's recommendation. Press "F" to keep original input commands. And the update did not do anything. But now I get a message like: Reading flash ........ done Bootblock checksum ... ok Module checksums ..... bad Error: BIOS checksum error And the update stops. I tried some commands form this page: http://www.ami.com/support/downloads/txt/AFU_README.TXT But I don't try to much, the servers are still booting. Does anyone know how to update my servers to BIOS version 245? I used this version http://h20565.www2.hp.com/portal/site/hpsc/template.PAGE/public/psi/swdDetails/?sp4ts.oid=3884344&spf_p.tpst=swdMain&spf_p.prp_swdMain=wsrp-navigationalState%3Didx%253D%257CswItem%253DMTX_7bd12651ab954fdcb0d7ee164a%257CswEnvOID%253D54%257CitemLocale%253D%257CswLang%253D%257Cmode%253D%257Caction%253DdriverDocument&javax.portlet.begCacheTok=com.vignette.cachetoken&javax.portlet.endCacheTok=com.vignette.cachetoken and created a bootable USB stick sith HPQUSB.exe

    Read the article

  • Adaptec 6405 RAID controller turned on red LED

    - by nn4l
    I have a server with an Adaptec 6405 RAID controller and 4 disks in a RAID 5 configuration. Staff in the data center called me because they noticed a red LED was turned on in one of the drive bays. I have then checked the status using 'arcconf getconfig 1' and I got the status message 'Logical devices/Failed/Degraded: 2/0/1'. The status of the logical devices was listed as 'Rebuilding'. However, I did not get any suspicious status of the affected physical device, the S.M.A.R.T. setting was 'no', the S.M.A.R.T. warnings were '0' and also 'arcconf getsmartstatus 1' returned no problems with any of the disk drives. The 'arcconf getlogs 1 events tabular' command gives lots of output (sorry, can't paste the log file here as I only have remote console access, I could post a screenshot though). Here are some sample entries: eventtype FSA_EM_EXPANDED_EVENT grouptype FSA_EXE_SCSI_GROUP subtype FSA_EXE_SCSI_SENSE_DATA subtypecode 12 cdb 28 00 17 c4 74 00 00 02 00 00 00 00 data 70 00 06 00 00 00 00 00 00 00 00 00 02 00 00 00 00 00 00 00 00 00 00 00 00 0 The 'arcconf getlogs 1 device tabular' command reports mediumErrors 1 for two of the disks. Today, I have checked the status of the controller again. Everything is back to normal, the controller status is now 'Logical devices/Failed/Degraded: 2/0/0', the logical devices are also all back to 'Optimal'. I was not able to check the LED status, my guess is that the red LED is off again. Now I have a lot of questions: what is a possible cause for the medium error, why it is not reported by the SMART log too? Should I replace the disk drives? They were purchased just a month ago. The rebuilding process took one or two days, is that normal? The disks are 2 TByte each and the storage system is mostly idling. the timestamp of the logs seem to show the moment of the log retrieval, not the moment of the incident. Please advise, all help is very appreciated.

    Read the article

  • SQL Server 2008 Cluster Installation - First network name always fails

    - by boflynn
    I'm testing failover clustering in Windows Server 2008 to host a SQL Server 2008 installation using this installation guide. My base cluster is installed and working properly, as well as clustering the DTC service. However, when it comes time to install SQL Server, my first attempt at installation always fails with the same message and seems to "taint" the network name. For example, with my previous cluster attempt, I was installing SQL Server as VSQL. After approximately 15 attempts of installation and trying to resolve the errors, e.g. changing domain accounts for SQL, setting SPNs, etc., I typoed the network name as VQSL and the installation worked. Similarly on my current cluster, I tried installing with the SQL service named PROD-C1-DB and got the same errors as last time until I tried changing the name to anything else, e.g. PROD-C1-DB1, SQL, TEST, etc., at which point the install works. It will even install to VSQL now. While testing, my install routine was: Run setup.exe from patched media, selecting appropriate options After the install fails, I'd chose "Remove node from a SQL Server failover cluster" and remove the single, failed, node Attempt to diagnose problem, inspect event logs, etc. Delete the computer account that was created for the SQL Service from Active Directory Delete the MSSQL10.MSSQLSERVER folder from the shared data drive The error message I receive from the SQL Server installer is: The following error has occurred: The cluster resource 'SQL Server' could not be brought online. Error: The group or resource is not in the correct state to perform the requested operation. (Exception from HRESULT: 0x8007139F) Along with hundreds of the following errors in the Application event log: [sqsrvres] checkODBCConnectError: sqlstate = 28000; native error = 4818; message = [Microsoft][SQL Server Native Client 10.0][SQL Server]Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. System configuration notes: Windows Server 2008 Enterprise Edition x64 SQL Server 2008 Enterprise Edition x64 using slipstreamed SP1+CU1 media Dell PowerEdge servers Fibre attached storage

    Read the article

  • DriveImage XML fails with a Windows Volume Shadow Service Error

    - by Ssvarc
    I'm trying to image a SATA laptop hard drive, using DriveImageXML, that is attached to my computer via a USB adapter. I'm running Win7 Ultimate 64 bit. DriveXML is returning: Could not initialize Windows Volume Shadow Service (VSS). ERROR C:\Program Files (x86)\Runtime Software\Drivelmage XML\vss64.exe failed to start. ERROR TIMEOUT Make sure VSSVC.EXE is running in your task manager. Click Help for more information. VSSVC.EXE is running in Task Manager, as is VSS64.exe. Looking at the FAQ on the Runtime webpage this turned up: Please verify in Settings-Control Panel-Administrative Tools-Services that the following services are enabled: MS Software Shadow Copy Provider Volume Shadow Copy Also make sure you are able to stop and start these services. Possible reasons for VSS failures: For VSS to work, at least one volume in your computer must be NTFS. If you use only FAT drives, VSS will not function. The required NTFS volume does not need to be identical with the volume you want to image. You should make sure that VSSVC.EXE is running in your task manager. If the problems persist, registering "oleaut.dll" and "oleaut32.dll" using "regsvr32" might help. Both of those services are running and can be started and stopped without issue. Using "regsvr32" to register ""oleaut32.dll" returns successful, but "oleaut.dll" returns: The module "oleaut.dll" failed to load. Make sure the binary is stored at the specified path or debug it to check for problems with the binary or dependent .DLL files. The specified module could not be found. Some other information that might be relevant. Browsing to the drive is successful, but accessing certain folders returns an "access" error. Windows runs a permissions adder that adds the current user profile to the NFTS permissions. Could this be the cause of the issue? DriveImage XML is running as Administrator. Thoughts?

    Read the article

  • "Dictionary problem." Error with VMPlayer

    - by George Mauer
    I'm pretty new to using vmware virtualization (been a virtualbox user) so I'm hoping you guys can help me out. I recently got an external usb disk containing a vm for a client, downloaded vmplayer, set it up with "Open a Virtual Machine", ran it, easy as pie. After working with it a bit this morning, I shut the VM down and now trying to start it back up again I get this: I tried removing the vm from my library, now it happens whenever I try to add it back in. In the meantime, I can still access other virtual machines so it seems like the problem might be with the virtual disk. So two questions: This is obviously not a very helpful error message. Where can I go to get more information? My Application EventLog doesn't contain anything from VMWare. What steps can I take to fix the problem? Edit: A couple more pieces of information. I did not take any snapshots. I don't think VM Player even has that ability. I have a zip file of (what I assume) is the state of the VM when it was sent to me. I cannot unzip it as it is huge and simply requires more HD space than I have available but I did extract the vmx file and examine it. Other than the UUIDs and the fact that mine reads cleanShutdown = "FALSE" they are identical. The log contains the following lines Jun 23 10:11:18.080: vmx| SNAPSHOT: SnapshotConfigInfoRead: Unable to load dict from 'E:....\MachineName.vmsd'. Jun 23 10:11:18.080: vmx| SNAPSHOT: SnapshotConfigInfoRead failed for file 'E:....\MachineName.vmx': Dictionary problem (6) Jun 23 10:11:18.082: vmx| SNAPSHOT: Snapshot_TimeStampTiers failed: Dictionary problem (6)

    Read the article

  • map subdomain to another subdomain via cname

    - by Stephen
    Question: I need to get DNS configured to point a subdomain from one domain (which I will generally not be controlling) to another subdomain on a different domain name. Testing this process using a simple CNAME entry keeps pointing to the primary domain and not the subdomain where it should be going. This is the scenario; (newdomain.com is in my control) cdn.xyz.com should display content from this subdomain subdomain.newdomain.com It is instead displaying content from newdomain.com (not the subdomain sub domain) cdn.xyz.com/page.htm displays content from newdomain.com/page.htm although what I need is it to display content from subdomain.newdomain.com/page.htm Other Background: setup is between two different servers with different IP ranges although DNS cluster is on between all servers the newdomain.com is set up with its own unique IP (which is on the A records for the subdomains, the subdomains work as expected/normal) the DNS entry is correct (cdn CNAME subdomain.newdomain.com.) ie the end period is included a DNS lookup on the CNAME externally reports back as subdomain.newdomain.com. as the record Does anyone know what DNS entries I am missing to get this working correctly ? Note: I do not want to just put a redirect between domains as I need the content of subdomain.newdomain.com/content.html to be visible via the URL of cdn.xyz.com/content.html also I can just use some redirects on newdomain.com to achieve what I am after but would prefer to just get the DNS correct. EDIT Current DNS cdn CNAME subdomain.newdomain.com. || CNAME entry for domain1 subdomain A XXX.XXX.XXX.XXX || A record entry for working subdomain pointing to unique IP What should happen is that cdn.domain1.com - subdomain.newdomain.com What is happening is cdn.domain1.com - newdomain.com (ie. the root not the subdomain) EDIT 2 Actually if its easier I am trying to emulate a simple cloud setup like Rackspace Containers (which I assume is similar to Buckets on AWS). although it is not for cloud storage Where a container has a url reference of hd62321678d323.rackspace.com (in truth they are much longer) so I can use a CNAME record of: cdn CNAME hd62321678d323.rackspace.com. so that http://cdn.mydomain.com/myfile.jpg displays content from http://hd62321678d323.rackspace.com/myfile.jpg

    Read the article

  • Task Scheduler not running .bat or .vbs successfully

    - by Django Reinhardt
    Hi there, got this weird problem, which will hopefully have an obvious solution for some enlightened soul: We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs script stopped successfully executing... but oddly it worked fine when ran manually! The error given in these circumstances was always "Timeout". We thought we try a little creative thinking, and run the .vbs another way: Via a .bat file. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file is nothing more than... CScript "C:\location\script.vbs" > Log.txt But the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The log.txt file says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • InnoDB: Error: log file ./ib_logfile0 is of different size

    - by jack
    I just added the following lines in /etc/mysql/my.cnf after I converted one database to use InnoDB engine. innodb_buffer_pool_size = 2560M innodb_log_file_size = 256M innodb_log_buffer_size = 8M innodb_flush_log_at_trx_commit = 2 innodb_thread_concurrency = 16 innodb_flush_method = O_DIRECT But it raise "ERROR 2013 (HY000) at line 2: Lost connection to MySQL server during query" error restarting mysqld. And mysql error log shows the following InnoDB: Error: log file ./ib_logfile0 is of different size 0 5242880 bytes InnoDB: than specified in the .cnf file 0 268435456 bytes! 100118 20:52:52 [ERROR] Plugin 'InnoDB' init function returned error. 100118 20:52:52 [ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed. 100118 20:52:52 [ERROR] Unknown/unsupported table type: InnoDB 100118 20:52:52 [ERROR] Aborting So I commented out this line # innodb_log_file_size = 256M And it restarted mysql successfully. I wonder what's the "5242880 bytes of log file" showed in mysql error? It's the first database on InnoDB engine on this server so when and where is that log file created? In this case, how can I enable innodb_log_file_size directive in my.cnf? EDIT I tried to delete /var/lib/mysql/ib_logfile0 and restart mysqld but it still failed. It now shows the following in error log. 100118 21:27:11 InnoDB: Log file ./ib_logfile0 did not exist: new to be created InnoDB: Setting log file ./ib_logfile0 size to 256 MB InnoDB: Database physically writes the file full: wait... InnoDB: Progress in MB: 100 200 InnoDB: Error: log file ./ib_logfile1 is of different size 0 5242880 bytes InnoDB: than specified in the .cnf file 0 268435456 bytes! Resolution It works now after deleted both ib_logfile0 and ib_logfile1 in /var/lib/mysql

    Read the article

  • blu-ray archiving in vmware ESXi 4

    - by spacecadet77
    Hi, I need some advice about using blu-ray writer for archiving data on vmware ESXi 4. At office we have IBM System x3400 Tower server with ESXi 4 hipervisor and OpenSuse and CentOS GNU/Linux system as guests. Will blu-ray writer work in this setup, and if it will is there any particular model you can suggest. Best regards IBM System x3400 Tower server specification: 1x Intel Quad-Core Xeon E5410 2.33GHz/ 12MB/ 1333MHz (2x CPU max) Intel 5000P chipset, 2x 1GB PC2-5300 DDR2 667MHz SDRAM ECC Chipkill (32GB max) 2x4GB (2x2GB) PC2-5300 CL5 ECC DDR2 FBDIMM (x3400, x3550, x3650) SAS/SATA Hot-Swap Open Bay (0xHDD std, 4xHDD max, 8xHDD optional) ServeRAID 8K dual channel SAS/SATA controller (RAID 0,1,1E,10,5,6, 256MB, Battery Backup) Graphics ATI® RN50(ES1000) 16MB DDR, CD-RW/DVD Combo no FDD GigaEthernet, Tower with Power Supply 835W (opt Redudant) Slot 1: half-length, PCI-Express x8(x4 electrical) Slot 2: full, PCI-Express x8 Slot 3: full, PCI-Express x8 Slot 4: full, 64-bit 133MHz 3.3v PCI-X Slot 5: full, 64-bit 133MHz 3.3v PCI-X , Slot 6: half-length, 32-bit 33MHz 5.0v PCI ports: 4x USB (Vers 2.0), 2x PS/2, parallel, 2x serial (9-pin), VGA, RJ-45 (ethernet ), RJ-45 (sys mgm) HDD 4 x TB 7200rpm / Serial ATA II 3.0Gb/s / 16MB, RoHS

    Read the article

  • Task Scheduler not able to execute .vbs scripts successfully

    - by Django Reinhardt
    Apologies if this has a really obvious answer! We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs scripts stopped successfully executing (always timing out)... but could still be executed manually with no problems(!). Not knowing any good reason why the Task Scheduler should start having problems, we thought we'd try a little "creative thinking", and run the .vbs another way: Via a .bat file executed by the Task Scheduler. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file run by Task Scheduler is nothing more than... CScript "C:\location\script.vbs" > Log.txt But after an attempt to run it, the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The Log.txt (as output from the .bat file above) says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • What exactly is a Mobile mouse? + Mouse Recommendation

    - by chobo2
    I am really disappointed with Logitech. My first cordless wireless mouse was from them and it lasted like 5 years. So I decided to get another one from them http://www.futureshop.ca/catalog/proddetail.asp?logon=&langid=EN&sku_id=0665000FS10099373&catid= And this mouse sucks bad. After 6 months it broke. I returned it under warranty and got a new one now 4-6 month later it is on the verge of breaking again.... You pay like $50 for this mouse and it lasts like 6 months that sad. I just lost faith in Logitech mice as I remember my bro also had a logitech mouse too and it broke after like 6 months. He then bought another logitech mouse(different model) that has been working for maybe 2 years(and no signs of breaking) but I am not crazy about the mouse(I don't like the 2 buttons by the wheel) and I not sure if they even sell it(maybe they got rid of it because it lasts too long). http://www.tigerdirect.ca/applications/SearchTools/item-details.asp?EdpNo=1578495&CatId=1285 So I am looking at a Microsoft mouse. http://www.futureshop.ca/catalog/proddetail.asp?logon=&langid=EN&sku_id=0665000FS10125565&catid= I am looking at this one but I am not sure what they mean by mobile mouse. I think that is what MS calls notebook mice. So I am not sure if this would be a good mouse to get for a desktop. I see it uses like a micro usb receiver but I am not sure if it is smaller then a standard mouse. But almost all the mice I looked at at futureshop.ca or staples are labeled notebook mice or mobile mice. So not sure what mice would be right for me. I don't want a corded one though. I really liked the LX6 design alot but it can't last more than 6 months. Thanks

    Read the article

  • Replacing DropBox with: Amazon S3 + SSL + GPG/TrueCrypt + Mounting on OSX ??

    - by Matt Rogish
    So, right now we're using DropBox to share various data files around between approximately 10 Mac OS X systems. However, we already have an S3 account and everyone on the lowest DropBox plan of $10/mo seems too expensive. We'd like to avoid any kind of local storage (share a disk on a desktop or something) since we're a geographically distributed team). So, I am contemplating something that would allow us to replace DropBox with our own home-grown solution. We are all fairly technical people and/or smart enough to follow some steps, so if it's not as "user friendly" as DropBox we're all comfortable with that. There are plenty of docs out there that have bits and pieces of what I want but some of the tools don't seem to fit the requirements: Transport security via SSL to the bucket Encryption of bucket contents Bi-directional syncing Most of the scripts I can find on the internet use "duplicity" which appears to fail #1 (it doesn't look like duplicity supports SSL to S3 - the docs don't state but the protocol looks plain old http http://www.nongnu.org/duplicity/duplicity.1.html#sect6 ) Many scripts use gpg to encrypt files. This seems like it could work, however I have to make sure that each OSX client is able to use the same key to encrypt and decrypt files (key management is left to me to manage). FTP and other client-based apps don't seem to support this at all. Finally, most of the scripts use one-way replication, e.g. using Amazon S3 as a simple backup store. As we'd be using Amazon S3 as the "repository" they fail this one. Whew. So, I'd love a single tool that does this but after an exhaustive search I don't think one exists. In my mind, the magical tool would be some combination of TrueCrypt and rsync. I'd be happy just knowing which tools out there can fulfill my 3 requirements, after that I can stitch together the rest. Any thoughts? THANKS!

    Read the article

  • Windows 7 Sysprep Default User

    - by Demonwolf
    I seem to be having a problem with implementing my sysprep. I have been playing with Windows 7, WAIK, Server 2008 R2 and various other things. I managed to create a WIM with everything I need installed and I have worked out the autounattend.xml. I now have a Windows 7 64-bit complete unattended install from a USB device. It has all my programs, setting and everything done except one thing - the default profile set up 100% correctly. I have created a mostly set up default profile. I booted into audit mode, customized the Administrator account (mostly anyway) and then used sysprep with an unattend.xml file containing the copyprofile=true command. The file was set up with the WSIM and does not contain any extra info. This all works wonderfully. I recreated the WIM and all was good. I then decided to move the default location of the visible stuff in the user profile (Documents, Music, Pictures etc.) without changing the location of Appdata or other hidden folders. This is where things went a little... wrong. I went to the user folder (generally has the User name) with all the other folders in it. I right clicked on My Documents, found the location tab and changed it to M:\Documents. Now if I run sysprep /generalize /oobe /reboot /unattend:unattend.xml it starts the generalise... then spits out a fatal error and goes no further. The setuperr.log contains the following errors: 2011-08-18 23:21:43, Error [0x0f0043] SYSPRP WinMain:The sysprep dialog box returned FALSE 2011-08-18 23:31:57, Error [0x0f0082] SYSPRP LaunchDll:Failure occurred while executing 'C:\Windows\System32\slc.dll,SLReArmWindows', returned error code -1073425657 2011-08-18 23:31:57, Error [0x0f0070] SYSPRP RunExternalDlls:An error occurred while running registry sysprep DLLs, halting sysprep execution. dwRet = -1073425657 2011-08-18 23:31:57, Error [0x0f00a8] SYSPRP WinMain:Hit failure while processing sysprep generalize internal providers; hr = 0xc004d307 Does anyone have any ideas how I can redirect My Documents and other items in a user file to a second drive in the default profile so it affects each person logging in?

    Read the article

  • Audio Static/Interference regardless of audio interface?

    - by Tom
    I currently am running a media center/server on a Lubuntu machine. The machine specs: Core 2 Duo Extreme EVGA SLI 680i MotherBoard 2 GB DDR2 Ram 3 Hard Drives no raid - WD Caviar Black, Green, and Samsung Spinpoint Galaxy GTX 220 1GB External USB Creative XI-FI Extreme Card 550W Power Supply This machine is hooked up through an optical cable to an ONKYO HTR340 Receiver through the XIFI card. Whenever I play any audio regardless if it is through XBMC, the default audio player, a flash video, etc, I get a horrible static sound that randomly gets louder. Here is a video of the sound: http://www.youtube.com/watch?v=SqKQkxYRVA4 This static comes in randomly, sometimes going away for short periods, but eventually always comes back. So far I have tried everything I could think of: Reinstalling OS Installing/upgrading/repairing PulseAudio/Alsa Installing alternate OSes, straight Ubuntu, Lubuntu, Xubuntu, Arch, Mint, Windows 7 Switching audio from the external card to internal Optical, audio out through HDMI, audio out through headphones Different ports on receiver (my main desktop sounds fine on the same sound system) Different optical cables Unplugging everything unnecessary from the motherboard (1 HD, 1 Stick of Ram, 1 Keyboard) Swapping out ram Swapping out the motherboard Replacing the Graphics Card (was replaced due to fan being noisy, not specifically for this problem) Different harddrives Swapping power supply Disabling onboard audio Pretty much everything short of swapping the CPU. I haven't been able to narrow down the problem and it is getting frustrating. Is it possible that the CPU is faulty and might cause a problem such as this, or that the PC case is shorting out the motherboard? Any kind of suggestions will be appreciated.

    Read the article

  • Toshiba Portege M400 screen rotation not working under Windows 7 x64

    - by Christi
    I have installed Windows 7 on my Toshiba Portege M400. This in itself was relatively tricky.* However, the button utilities aren't quite working for me. One of the buttons tries to launch the Toshiba Assist program, which doesn't appear to be available under Windows 7 for the M400, but this I can live without. More important is that the screen won't rotate as it is supposed to when you hold the "cancel" (X in a circle) button on the bezel. The PC is set to run "C:\Program Files (x860\Toshiba\Toshiba Rotation Utility\phtrot.exe". There is a "trot.exe" file in the same directory (the former appears to be to cause slightly different behaviour when rotation is done by press and hold). Neither of these programs rotates the screen either by using the buttons or from the command line. The screen is rotating normally when switching from tablet to laptop mode, so there does not appear to be an inherent problem with rotation. I'd just like to be able to use the buttons on the side of the screen to change the screen orientation. Windows XP used to have a "setrot" utility to do this, but that seems to have gone in Windows 7 Thanks for your help. *Just in case anyone comes looking for how to do this, you need to extract driver files from http://cdgenp01.csd.toshiba.com/content/support/downloads/util_raid_os2007252a.exe, which does not seem to be listed among the available files for the m400. This executable contains the SATA interface drivers that will need to be loaded by the installer before it can see your hard disk drive. It needs to be unpacked and the files copied to a USB key which they can then be loaded from in the install process. The utilities etc. for installation post windows install are all available from the Toshiba USA support website.

    Read the article

  • playsms sent sms to queue

    - by user512213
    i install playsms in my system as below mentioned way https://github.com/antonraharja/playSMS/wiki/Web-User-Interface-Installation i use kannel as a gateway and kannel running fine i get the following status while i check kannel status in browser. Kannel bearerbox version `1.4.3'. Build `Nov 24 2011 08:02:18', compiler `4.6.2'. System Linux, release 3.2.0-23-generic-pae, version #36-Ubuntu SMP Tue Apr 10 22:19:09 UTC 2012, machine i686. Hostname MSSRF-INCOIS, IP 127.0.1.1. Libxml version 2.7.8. Using OpenSSL 1.0.0e 6 Sep 2011. Compiled with MySQL 5.5.17, using MySQL 5.5.24. Using SQLite 3.7.9. Using native malloc. Status: running, uptime 0d 1h 8m 27s WDP: received 0 (0 queued), sent 0 (0 queued) SMS: received 0 (0 queued), sent 0 (0 queued), store size -1 SMS: inbound (0.00,0.00,0.00) msg/sec, outbound (0.00,0.00,0.00) msg/sec DLR: 0 queued, using internal storage Box connections: wapbox, IP 127.0.0.1 (on-line 0d 1h 8m 2s) wapbox, IP 127.0.0.1 (on-line 0d 0h 18m 11s) SMSC connections: unknown AT2[/dev/ttyS0] (online 4106s, rcvd 0, sent 0, failed 0, queued 0 msgs) But when i try to send sms in playsms means it shows "Your SMS has been delivered to queue " but sms not received .Any thing we missed out while configuration.any one advice me to proceed.

    Read the article

  • Configuration management in support of scientific computing

    - by Sharpie
    For the past few years I have been involved with developing and maintaining a system for forecasting near-shore waves. Our team has just received a significant grant for further development and as a result we are taking the opportunity to refactor many components of the old system. We will also be receiving a new server to run the model and so I am taking this opportunity to consider how we set up the system. Basically, the steps that need to happen are: Some standard packages and libraries such as compilers and databases need to be downloaded and installed. Some custom scientific models need to be downloaded and compiled from source as they are not commonly provided as packages. New users need to be created to manage the databases and run the models. A suite of scripts that manage model-database interaction needs to be checked out from source code control and installed. Crontabs need to be set up to run the scripts at regular intervals in order to generate forecasts. I have been pondering applying tools such as Puppet, Capistrano or Fabric to automate the above steps. It seems perfectly possible to implement most of the above functionality except there are a couple usage cases that I am wondering about: During my preliminary research, I have found few examples and little discussion on how to use these systems to abstract and automate the process of building custom components from source. We may have to deploy on machines that are isolated from the Internet- i.e. all configuration and set up files will have to come in on a USB key that can be inserted into a terminal that can connect to the server that will run the models. I see this as an opportunity to learn a new tool that will help me automate my workflow, but I am unsure which tool I should start with. If any member of the community could suggest a tool that would support the above workflow and the issues specific to scientific computing, I would be very grateful. Our production server will be running Linux, but support for OS X would be a bonus as it would allow the development team to setup test installations outside of VirtualBox.

    Read the article

< Previous Page | 373 374 375 376 377 378 379 380 381 382 383 384  | Next Page >