Search Results

Search found 6859 results on 275 pages for 'advanced installer'.

Page 38/275 | < Previous Page | 34 35 36 37 38 39 40 41 42 43 44 45  | Next Page >

  • How to update the InnoSetup Wizard GUI status text from PascalScript code

    - by mkva
    Hi I execute a lot of custom actions in my InnoSetup script in the CurStepChanged(ssPostInstall) PascalScripting event handler. As these actions take some time to finish, I'd like to update the InnoSetup Wizard GUI status text and tell the user what is going on behind the scenes. Something similar that is possible in the [Run] section using the "StatusMsg" parameter. I know that I could use the TOutputProgressWizardPage/CreateOutputProgressPage(), and I did in a previous project, but it's a bit too much overkill to my liking... Is there a simpler possibility to update the InnoSetup Wizard GUI status text from PascalScripting code with the same effect as the StatusMsg parameter?

    Read the article

  • wix The directory is in the user profile but is not listed in the RemoveFile table

    - by Venkat S. Rao
    I have the following configuration to delete and copy a file from WIX. <Directory Id='TARGETDIR' Name='SourceDir'> ... <Directory Id="AppDataFolder" Name="AppDataFolder"> <Directory Id="GleasonAppData" Name="Gleason" > <Directory Id="GleasonStudioAppData" Name="GleasonStudio"> <Directory Id="DatabaseAppData" Name ="Database"> <Directory Id="UserSandboxesAppData" Name="UserSandboxes" /> </Directory> </Directory> </Directory> </Directory> </Directory> <DirectoryRef Id="UserSandboxesAppData"> <Component Id="comp_deleteBackup" Guid="1f159f49-3029-4f46-b194-e42aabd40844"> <RemoveFile Id="RemoveBackup" Directory="UserSandboxesAppData" Name="DevelopmentBackUp.FDB" On="install" /> <RegistryKey Root="HKCU" Key="Software\Gleason\Database\RemoveBackup"> <RegistryValue Value="Removed" Type="string" KeyPath="yes" /> </RegistryKey> </Component> <Component Id="comp_createBackup" Guid="557badef-6d77-4c4e-aa5f-8d88cb5ef735"> <CopyFile Id="DBBackup" DestinationDirectory="UserSandboxesAppData" DestinationName="DevelopmentBackUp.FDB" SourceDirectory="UserSandboxesAppData" SourceName="Development.FDB" /> <RegistryKey Root="HKCU" Key="Software\Gleason\Database\CopyBackup"> <RegistryValue Value="Copied" Type="string" KeyPath="yes" /> </RegistryKey> </Component> </DirectoryRef> I get 4 errors related to ICE64--The directory 'xxx' is in the user profile but is not listed in the RemoveFile table. xxx={UserSandboxesAppData, DatabaseAppData, GleasonStudioAppData, GleasonAppData} Someone else had a very similar problem here: Directory xx is in the user profile but is not listed in the RemoveFile table. . But that solution did not help me. What do I need to change? Thank You, Venkat Rao

    Read the article

  • JScrollPane Scrolls Down with Long Text in JEditorPane

    - by Jim
    Hello, I want to have a JEditorPane inside a JScrollPane. When the user clicks a button, the click listener will create a textEditor, call jscrollpane.setViewPort(textEditor), call textEditor.setText(String) to fill it with editable text, and call jscrollpane.getVerticalScrollBar().setValue(0). In case you're wondering, yes, the setText() must come after the setViewPort() for reasons that aren't on topic. Here is the problem: After the user clicks the button, the JScrollPane's view scrolls all the way to the bottom. I want the scrollbar to be at the top, as per the last line in my click listener. I popped open a debugger, and to my horror, discovered that the jscrollpane's viewport is being forced down to the bottom after the conclusion of the click listener (when pumping filters). It appears that Swing is delaying the population of the editor/jscrollpane until after the conclusion of the clicklistener, but is calling the scrollbar command first. Thus, the undesired behavior. Anyway, I'm wondering if there is a clean solution. It seems that wanting a scrollpane to be scrolled to the top after modification would be a reasonably common requirement, so I'm assuming this is a well-solved problem. Thanks!

    Read the article

  • Best Installation Software?

    - by Chris
    I am interested in knowing what the best software would be to build an installation package that performs the following: (1) Installs client application (2) Detects all SQL server instances on network, allowing user to select specific database to upgrade (which would then upgrade database using an embedded SQL script) (3) Installs website on a server/location specified by user, and configures IIS 6.0 and/or 7.0 based on settings that I specify. (4) Creates a simple setup.exe - and allows user to choose installation components (listed above, i.e install client app, sql server database, and/or website), and then download selected components from remove server. I have tried NSIS - as was able to create an installation package that will download a compressed (gzip) component from a remote server, decompress the file, install the components, and then remove the gzip file. So, this worked beautifully. The part where I am stuck is to be able to perform the database upgrade and website install. Any suggestions would be great. Thanks. Chris

    Read the article

  • HOWTO and best working installation (MSI) chainer +/ bootstrapper

    - by davidovitz
    Hi, Our product has several products that customer can install created as separate installation packages (MSI). We have a requirement to have single package for the installation that will: Show one UI with progress Allow user to choose which features/packages to install Have ability to constrain one feature to another (e.g removing or adding effect other) Support single elevation (UAC) nice to have ability to auto update (not must) support command line + silent installation the package should be built out of the isolated installations (chain them) raise error / messages for missing prerequisites Support patches over time and major upgrades Today we do almost all of the above using MSI with nested installations which is bad practice and we face too many issues in our solution. i know that there are several bootstrappers out there (m$ generic bootstrapper which i think is not good, BURN is the WIX version which is not mature enough) Do you know of other? that work and tested already ? What is the best method to do (without unification of the MSI into a single MSI)

    Read the article

  • WiX ServiceDependency for dynamically named services

    - by glenneroo
    The target system will have a set of dynamically-named CORBA services installed that my own service is dependent on e.g. IT iona_services.config_rep.VirtualXP-37192 cfr-DOMAIN IT iona_services.event.VirtualXP-37192 DOMAIN IT iona_services.ifr.VirtualXP-37192 DOMAIN IT iona_services.locator.VirtualXP-37192 DOMAIN IT iona_services.naming.VirtualXP-37192 DOMAIN IT iona_services.node_daemon.VirtualXP-37192 DOMAIN where "VirtualXP-37192" is the name of the PC. Any ideas what i have to put into this line: <ServiceDependency Id="IT iona_services.*" Group="yes" /> Will i need a custom action thingy to retrieve a list of installed services and search through those? Or is there a way in WiX to retrieve a list of services?

    Read the article

  • Modifying setup file with PHP

    - by Paul Lammertsma
    I have an application that needs branding when downloaded in certain continents. When installed in North America, for instance, the application, when run, displays a different logo and company name than in Europe. The setup file is provided through a PHP script. Presently there is a Inno Setup executable for Windows and a DMG for Mac OS X. I have seen that when downloading Google Chrome, you can specify whether or not it should send usage statistics. A brief look at the JavaScript that controls it reveals that this is simply sent back to the server with &usagestats=0 or &usagestats=1. How would I go about influencing the installation based upon settings specified via the PHP download page?

    Read the article

  • Mysql SELECT nested query, very complicated?

    - by smartbear
    Okay, first following are my tables: Table house: id | items_id | 1 | 1,5,10,20 | Table items: id | room_name | refer 1 | kitchen | 3 5 | room1 | 10 Table kitchen: id | detail_name | refer 3 | spoon | 4 5 | fork | 10 Table spoon: id | name | color | price | quantity_available | 4 | spoon_a | white | 50 | 100 | 5 | spoon_b | black | 30 | 200 | How to do a nested select statement, where I want to select id, name, color, price and quantity_available column, from the each value inside the 'items_id' column in 'house' table? This is very challenging!! EDIT: after read robin's answer Table house: id | items_id | house1 | 1 | house1 | 5 | house1 | 10 | house2 | 20 | If this it the house table, how to do the nested, join, or whatever select statement??

    Read the article

  • Wrong EXE file shown in start menu on Windows 7

    - by Zach
    Hello all, My software has two .EXE files : A.exe and B.exe. After installed on Window 7, the shortcut to A.exe is always shown in the start menu. (I don't know if 'Start menu' is the correct name or not, what I mean is the area above 'All Programs'). The menu in my computer looks like: Getting Started Windows Media Center Calculator Sticky Notes Snipping Tool Paint A <-- My program, and I want 'B' to be shown here All programs How can I make B.exe shown instead of A.exe? Best regards, Zach

    Read the article

  • Replacing unversioned files in WiX major upgrade.

    - by Joshua
    I am still having this problem. This is the closest I have come to a solution that works, and yet it doesn't quite work. Here is (most of) the code: <Product Id='$(var.ProductCode)' UpgradeCode='$(var.UpgradeCode)' Name="Pathways" Version='$(var.ProductVersion)' Manufacturer='$(var.Manufacturer)' Language='1033'> Maximum="$(var.ProductVersion)" IncludeMaximum="no" Language="1033" Property="OLDAPPFOUND" / -- -- -- There is a later version of this program installed. The problem I am having is that I need the two files in the Database component to replace the previous copies. Since these files are unversioned, I have attempted to use the CompanionFile tag set to the PathwaysExe since that is the main executable of the application, and it IS being updated, even if the log says it isn't! The strangest thing about this is that the PathwaysLdf file IS BEING UPDATED CORRECTLY, and the PathwaysMdf file IS NOT. The log seems to indicate that the "Existing file is of an equal version (Checked using version of companion)". This is very strange because that file is being replaced just fine. The only idea I have left is that this problem has to do with the install sequence, and I'm not sure how to proceed! I have the InstallExecuteSequence set like I do because of the SettingsXml file, and my need to NOT overwrite that file, which is actually working now, so whatever solution works for the database files can't break the working settings file! ;) The full log is located at: http://pastebin.com/HFiGKuKN PLEASE AND THANK YOU!

    Read the article

  • Hidden Features of ASP.NET

    - by Vaibhav
    There are always features that would be useful in fringe scenarios, but for that very reason most people don't know them. I am asking for features that are not typically taught by the text books. What are the ones that you know?

    Read the article

  • How does the setup bootstrapper detect if prerequisites are installed?

    - by Marek
    Trying to solve this problem. I would like to learn how the bootstrapper detects if prerequisites (specifically .NET 3.5) are installed. According to this reference, a way to detect if .NET is installed is to check the following registry key: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\NET Framework Setup\NDP\v3.5 Using process monitor, I have inspected registry queries done by the bootstrapper (setup.exe) and it did not show any access to this registry key. Does anybody know how the bootstrapper determines whether the prerequisites are installed on the target system?

    Read the article

  • Late resolution of MSI variable for part of install folder path

    - by Don Vince
    In a setup project, on User Interface, I've created a RadioButtons (3 Buttons) dialog box. I've placed it before the Installation Folder Dialog. I wish to incorporate the value selected in the RadioButtons dialog as part of the Installation Folder. To do this I've placed the name of the variable amongst the path where I wish to use it in the DefaultLocation: [ProgramFilesFolder][Manufacturer]\[ProductName]\[BUTTON3] The effect of this is that the default value for the variable, BUTTON3 in the example above, is resolved as part of the folder, not the selected value. Anybody know how to make this variable use delayed expansion in some way to get the selected value?

    Read the article

  • Direct TCP/IP connections in P2P apps

    - by Greg Roberts
    From a Joel's post on Copilot: Direct Connect! We’ve always done everything we can to make sure that Fog Creek Copilot can connect in any networking situation, no matter what firewalls or NATs are in place. To make this happen, both parties make outbound connections to our server, which relays traffic on their behalf. Well, in many cases, this isn’t necessary. So version 2.0 does something rather clever: it sets up the initial connection through our servers, so you get connected right away with 100% reliability. But then once you’re all connected, it quietly, in the background, looks for a way to make a direct connection. If it can’t, no big deal: you just keep relaying through our server. If you can make a direct peer-to-peer connection, it silently shifts your data onto the direct connection. You won’t notice anything except, probably, much faster communication. How do they change the server connection to a P2P connection?

    Read the article

  • Simplest solution to replace a tiny file inside an MSI?

    - by sascha
    Many of our customers have access to InstallShield, WISE or AdminStudio. These aren't a problem. I'm hoping there is some way I can provide our smaller customers without access to commercial repackaging tools a freely available set of tools and steps to do the file replacement themselves. Only need to replace a single configuration file inside a compressed MSI, the target user can be assumed to already have Orca installed, know how to use this to customize the Property table (to embed license details for GPO deployment) and have generated an MST file. Disclaimer: this is very similar to another question but both questions and answers in that thread are not clear.

    Read the article

  • Creating a MSI patch (.msp) by hand?

    - by Jerry Chong
    Our team has recently been considering pushing out a minor registry fix to users to modify one particular problematic key. Pretty straightforward stuff, just needed to update 1 key/value inside the registry. So at the moment, we are using Wix to build .msi installers for the product. While looking into Wix's support for generating .msp patch files, it seems that the only way to create an .msp is a somewhat overcomplicated multi-step process to: Get a copy of the original MSI, and compile a new copy of the fixed MSI Write a new Wix file that points to both installers Compile the Wix file into a .wixobj with Candle to a .psp Run Torch/Pyro over before/after snapshots of the original installers and the .psp, or alternatively using MsiMsp.exe Now my question is, can't I simply describe the registry change into a Wix file and directly compile it into the .msp, without step 1 and 4 - which is a huge amount of effort for just a simple change?

    Read the article

  • Oracle AQ dequeue order

    - by yawn
    A trigger in an Oracle 10g generates upsert and delete messages for a subset of rows in a regular table. These messages consist out of two fields: A unique row id. A non-unique id. When consuming these message I want to impose an order on the deque process that respects the following constraints: Messages must be dequeued in insertion order. Messages belonging to the same id must be dequeued in such a fashion that no other dequeuing process should be able to dequeue a potential successor message (or messages) with this id. Since the messages are generated using a trigger I cannot use groups for this purpose. I am using the Oracle Java interface for AQ. Any pointers on how that could be achieved?

    Read the article

  • How can I remove .NET isolated storage setting folders during WiX uninstallation?

    - by Luke
    I would like to remove the isolated storage folders that are created by a .NET application when using My.Settings etc. The setting files are stored in a location like C:\Users\%Username%\AppData\Roaming\App\App.exe_Url_r0q1rvlnrqsgjkcosowa0vckbjarici4 As per this question StackOverflow: Removing files when uninstalling Wix I can uninstall a folder using: <Directory Id="AppDataFolder" Name="AppDataFolder"> <Directory Id="MyAppFolder" Name="My"> <Component Id="MyAppFolder" Guid="YOURGUID-7A34-4085-A8B0-8B7051905B24"> <CreateFolder /> <RemoveFile Id="PurgeAppFolder" Name="*.*" On="uninstall" /> </Component> </Directory> </Directory> <!-- LocalAppDataFolder--> This doesn't support sub-folders etc. Is the only option a custom .NET action or is there a more simple approach for removing these .NET generated setting folders?

    Read the article

  • Can I read AssemblyFile information in Inno Setup

    - by Nifle
    I would like to read these three values from my application.exe in my Inno Setup script. [assembly: AssemblyCompany("My Company")] [assembly: AssemblyProduct("My Great Application")] [assembly: AssemblyFileVersion("9.3.2")] Does anyone know how this might be accomplished? I know I can get the last one using GetFileVersion("path/to/greatapp.exe") is there something similar for the first two?

    Read the article

< Previous Page | 34 35 36 37 38 39 40 41 42 43 44 45  | Next Page >