Search Results

Search found 14145 results on 566 pages for 'level of detail'.

Page 38/566 | < Previous Page | 34 35 36 37 38 39 40 41 42 43 44 45  | Next Page >

  • Could someone explain in detail simplex /or perlin noise?

    - by Ryan Szemplinski
    I am really interested in perlin/simplex noise but I am having a difficult time understanding it. I am not very good at math but I am willing to learn because it interests me greatly. If someone is willing to dedicate there time into this I would be immensely appreciative of this. To be more concise, an explanation of functions and some calculation inside the functions would be nice to understand. Thanks in advance!

    Read the article

  • How do I randomly generate a top-down 2D level with separate sections and is infinite?

    - by Bagofsheep
    I've read many other questions/answers about random level generation but most of them deal with either randomly/proceduraly generating 2D levels viewed from the side or 3D levels. What I'm trying to achieve is sort of like you were looking straight down on a Minecraft map. There is no height, but the borders of each "biome" or "section" of the map are random and varied. I already have basic code that can generate a perfectly square level with the same tileset (randomly picking segments from the tileset image), but I've encountered a major issue for wanting the level to be infinite: Beyond a certain point, the tiles' positions become negative on one or both of the axis. The code I use to only draw tiles the player can see relies on taking the tiles position and converting it to the index number that represents it in the array. As you well know, arrays cannot have a negative index. Here is some of my code: This generates the square (or rectangle) of tiles: //Scale is in tiles public void Generate(int sX, int sY) { scaleX = sX; scaleY = sY; for (int y = 0; y <= scaleY; y++) { tiles.Add(new List<Tile>()); for (int x = 0; x <= scaleX; x++) { tiles[tiles.Count - 1].Add(tileset.randomTile(x * tileset.TileSize, y * tileset.TileSize)); } } } Before I changed the code after realizing an array index couldn't be negative my for loops looked something like this to center the map around (0, 0): for (int y = -scaleY / 2; y <= scaleY / 2; y++) for (int x = -scaleX / 2; x <= scaleX / 2; x++) Here is the code that draws the tiles: int startX = (int)Math.Floor((player.Position.X - (graphics.Viewport.Width) - tileset.TileSize) / tileset.TileSize); int endX = (int)Math.Ceiling((player.Position.X + (graphics.Viewport.Width) + tileset.TileSize) / tileset.TileSize); int startY = (int)Math.Floor((player.Position.Y - (graphics.Viewport.Height) - tileset.TileSize) / tileset.TileSize); int endY = (int)Math.Ceiling((player.Position.Y + (graphics.Viewport.Height) + tileset.TileSize) / tileset.TileSize); for (int y = startY; y < endY; y++) { for (int x = startX; x < endX; x++) { if (x >= 0 && y >= 0 && x <= scaleX && y <= scaleY) tiles[y][x].Draw(spriteBatch); } } So to summarize what I'm asking: First, how do I randomly generate a top-down 2D map with different sections (not chunks per se, but areas with different tile sets) and second, how do I get past this negative array index issue?

    Read the article

  • Le nouvel Hotmail pourra-t-il concurrencer Gmail ? Découvrez ses nouvelles fonctionnalités en détail

    Mise à jour du 19.05.2010 par Katleen Le nouvel Hotmail pourra-t-il concurrencer Gmail ? Découvrez ses nouvelles fonctionnalités en détails En matière de client mail, Microsoft est très en retard et part avec un gros handicap. Même si son service est celui qui compte le plus d'abonnés (majoritairement à cause de l'utilisation de Messenger), c'est aussi celui dont les utilisateurs sont le moins satisfait, face à un Gmail fonctionnel et sur, par exemple. La firme de Redmond a donc décidé de sortir l'artillerie lourde en remodelant totalement sa messagerie Hotmail. L'accent sera mis sur la sécurité, qui jusqu'ici laissait à désirer. Il sera désormais possible de s'authentifier grâce à des...

    Read the article

  • EPM 11.1.2 - Receive Anonymous Level Security token message in IE8 when trying to access Shared Services or Workspace URL

    - by Ahmed A
    If you get "Receive Anonymous Level Security token" message in IE8 when trying to access Shared Services or Workspace URL.Workaround:a. Go to Start > Run and enter dcomcnfgb. Expand Component Services, Expand Computers and right click on My Computer and select Propertiesc. Click on the Default Properties tab.  Change the Default Authentication Level to Connect.  Click apply and then OK.d. Launch the IE browser again and you will be able to access the URL.

    Read the article

  • Which connector do I need for a "line level" subwoofer?

    - by Ben Brocka
    I've got a separate pair of speakers and I'm looking at adding a subwoofer (this, specifically). I noticed on the detail page it's inputs are listed as such: Inputs: Speaker level, line level If I'm not mistaken "line level" are the standard 3.5 audio jacks on your motherboard/sound card, right? My motherboard has the standard 6 ports for sound, if I get a subwoofer like this can I simply plug the input into the orange 3.5 jack? My audio software supports up to 7.1 so software-wise, 2.1 wouldn't be a problem.

    Read the article

  • Are these interview questions too difficult for entry-level C++ positions?

    - by Banana
    I recently had a few interviews for programming jobs within the financial industry. I am looking for entry-level positions as I specify in the cover letter. However I am usually asked questions such as: - all two-letters commands you know in unix - representation of float/double numbers (ieee standard) - segmentation fault memory dump, and related issues - all functions you know to convert string to integer (not just atoi) - how to avoid virtual tables - etc.. Is that the custom? Because I don't think this kind of questions make sense for someone willing to get an entry-level job. Is it totally crazy to think that they should ask more conceptual questions? This is beginning to driving me nuts, honestly. Thanks

    Read the article

  • ASP.NET Menu: how to build custom menu

    - by Turi
    hi all, i have this situation: i have to build a menu with datasource from the db, because i have to filter them among the user that is loged in. i have tried building a menu using repeater, and all this works fine till i realized that i wanted the menu with more than two levels. i have also tried with treeview, but i really don't want this solution (problem with the style and the treeview doesn't have a pretty view). Could anyone give me just the idea ? thnx in advance.

    Read the article

  • Why is my masm32 program crashing whenever I try using interrupts?

    - by incrediman
    Here's the code: .386 ;target for maximum compatibility .model small,stdcall ;model .code main: int 20h END main Result: http://img705.imageshack.us/img705/3738/resultom.png "test.exe has stopped working" - always right when it reaches the interrupt. This is the interrupt I'm trying to use. It should simply exit the program. Others I've tried include character input/output, etc.. Nothing works. I'm on windows 7, using masm32 with the WinAsm IDE. There are so many cool things it seems I should be able to do with interrupts... however, it crashes whenever I try to use an interrupt - always the same way. This seems related and possibly useful: http://stackoverflow.com/questions/1414260/dos-interrupt-in-masm-x86-assembly-crashing ...but I haven't really been able to figure anything out from it. Any suggestions?

    Read the article

  • Locking a table for getting MAX in LINQ

    - by Hossein Margani
    Hi Every one! I have a query in LINQ, I want to get MAX of Code of my table and increase it and insert new record with new Code. just like the IDENTITY feature of SQL Server, but here my Code column is char(5) where can be alphabets and numeric. My problem is when inserting a new row, two concurrent processes get max and insert an equal Code to the record. my command is: var maxCode = db.Customers.Select(c=>c.Code).Max(); var anotherCustomer = db.Customers.Where(...).SingleOrDefault(); anotherCustomer.Code = GenerateNextCode(maxCode); db.SubmitChanges(); I ran this command cross 1000 threads and each updating 200 customers, and used a Transaction with IsolationLevel.Serializable, after two or three execution an error occured: using (var db = new DBModelDataContext()) { DbTransaction tran = null; try { db.Connection.Open(); tran = db.Connection.BeginTransaction(IsolationLevel.Serializable); db.Transaction = tran; . . . . tran.Commit(); } catch { tran.Rollback(); } finally { db.Connection.Close(); } } error: Transaction (Process ID 60) was deadlocked on lock resources with another process and has been chosen as the deadlock victim. Rerun the transaction. other IsolationLevels generates this error: Row not found or changed. Please help me, thank you.

    Read the article

  • Why WCAG made 3 level "A", "AA" and "AAA"?

    - by jitendra
    What is the purpose of making 3 priority level by WCAG? is it like? If client not paying extra or if we don't have much time then go for A If client paying then or if we have time to make site compatible go for at least AA If client paying and needed according to govt. rules then go for AAA If we are making site then which level we should we try to achieve, or we should do only on client request? Although i found these definitions on this site but these are confusing for me • Priority 1: For all users to access the Web content and for Web developers to attain Conformance level “A”, these requirements must be satisfied. • Priority 2: These requirements should be satisfied by the Web developers so that no group finds it difficult to access the Web content and so as to attain Conformance level “AA”. • Priority 3: These requirements may be satisfied by the Web developers to facilitate access to Web content for some groups and attain Conformance level “AAA”.

    Read the article

  • How does a portable Thread Specific Storage Mechanism's Naming Scheme Generate Thread Relative Uniqu

    - by Hassan Syed
    A portable thread specific storage reference/identity mechanism, of which boost/thread/tss.hpp is an instance, needs a way to generate a unique keys for itself. This key is unique in the scope of a thread, and is subsequently used to retrieve the object it references. This mechanism is used in code written in a thread neutral manner. Since boost is a portable example of this concept, how specifically does such a mechanism work ?

    Read the article

  • Tuning SQL Server 2008 for web applications

    - by Kibbee
    In one of the Stackoverflow podcasts, I remember Jeff Atwood saying that there was a configuration option in SQL Server 2008 which cuts down on locking, and was kind of an alternative to using "with (nolock)" in all your queries. Does anybody know how to enable the feature he was talking about, possibly even Jeff himself. I'm looking at deploying SQL Server 2008, and want to see if using a feature like this would help out my web application.

    Read the article

  • How to sum up values of an array in assembly?

    - by Pablo Fallas
    I have been trying to create a program which can sum up all the values of an "array" in assembly, I have done the following: ORG 1000H TABLE DB DUP(2,4,6,8,10,12,14,16,18,20) FIN DB ? TOTAL DB ? MAX DB 13 ORG 2000H MOV AL, 0 MOV CL, OFFSET FIN-OFFSET TABLE MOV BX, OFFSET TABLE LOOP: ADD AL, [BX] INC BX DEC CL JNZ LOOP HLT END BTW I am using msx88 to compile this code. But I get an error saying that the code 0 has not been recognized. Any advise?

    Read the article

  • A submenu (`ToolStripMenuItem`) does not show automatically.

    - by czuk
    I have encountered strange problem with a three-level context menu. In some situation the sub menu does not show automatically. I have following structure of the menu: * AAA - level 1 * BBB - level 1 * CCC - level 2 * xxx - level 3 * yyy - level 3 * DDD - level 2 * zzz - level 3 * vvv - level 3 I start from a menu with two option AAA and BBB. After I move the cursor over BBB the second-level menu appears with two other options CCC and DDD. So far OK. Now, when I quickly move the cursor over DDD the third-level sub menu does not show up, but when I move the cursor back to CCC the sub menu shows up, and when I go back to DDD then the sub menu also shows. Why it does not show at first time? Have you ever encountered such a problem? I fixed the problem with MouseEnter and MouseLeave events, but I still wonder why it does not work properly without the events.

    Read the article

  • AppFabric caching's local cache isnt working for us... What are we doing wrong?

    - by Olly
    We are using appfabric as the 2ndlevel cache for an NHibernate asp.net application comprising a customer facing website and an admin website. They are both connected to the same cache so when admin updates something, the customer facing site is updated. It seems to be working OK - we have a CacheCLuster on a seperate server and all is well but we want to enable localcache to get better performance, however, it dosnt seem to be working. We have enabled it like this... bool UseLocalCache = int LocalCacheObjectCount = int.MaxValue; TimeSpan LocalCacheDefaultTimeout = TimeSpan.FromMinutes(3); DataCacheLocalCacheInvalidationPolicy LocalCacheInvalidationPolicy = DataCacheLocalCacheInvalidationPolicy.TimeoutBased; if (UseLocalCache) { configuration.LocalCacheProperties = new DataCacheLocalCacheProperties( LocalCacheObjectCount, LocalCacheDefaultTimeout, LocalCacheInvalidationPolicy ); // configuration.NotificationProperties = new DataCacheNotificationProperties(500, TimeSpan.FromSeconds(300)); } Initially we tried using a timeout invalidation policy (3mins) and our app felt like it was running faster. HOWEVER, we noticed that if we changed something in the admin site, it was immediatley updated in the live site. As we are using timeouts not notifications, this demonstrates that the local cache isnt being queried (or is, but is always missing). The cache.GetType().Name returns "LocalCache" - so the factory has made a local cache. Running "Get-Cache-Statistics MyCache" in PS on my dev environment (asp.net app running local from vs2008, cache cluster running on a seperate w2k8 machine) show a handful of Request Counts. However, on the Production environment, the Request Count increases dramaticaly. We tried following the method here to se the cache cliebt-server traffic... http://blogs.msdn.com/b/appfabriccat/archive/2010/09/20/appfabric-cache-peeking-into-client-amp-server-wcf-communication.aspx but the log file had nothing but the initial header in it - i.e no loggin either. I cant find anything in SO or Google. Have we done something wrong? Have we got a screwy install of AppFabric - we installed it via WebPlatform Installer - I think? (note: the IIS box running ASp.net isnt in yhe cluster - it is just the client). Any insights greatfully received!

    Read the article

  • Does armcc optimizes non-volatile variables with -O0 ?

    - by Dor
    int* Register = 0x00FF0000; // Address of micro-seconds timer while(*Register != 0); Should I declare *Register as volatile while using armcc compiler and -O0 optimization ? In other words: Does -O0 optimization requires qualifying that sort of variables as volatile ? (which is probably required in -O2 optimization)

    Read the article

  • Basic data alignment question

    - by Broken Logic
    I've been playing around to see how my computer works under the hood. What I'm interested in is seeing is what happens on the stack inside a function. To do this I've written the following toy program: #include <stdio.h> void __cdecl Test1(char a, unsigned long long b, char c) { char c1; unsigned long long b1; char a1; c1 = 'b'; b1 = 4; a1 = 'r'; printf("%d %d - %d - %d %d Total: %d\n", (long)&b1 - (long)&a1, (long)&c1 - (long)&b1, (long)&a - (long)&c1, (long)&b - (long)&a, (long)&c - (long)&b, (long)&c - (long)&a1 ); }; struct TestStruct { char a; unsigned long long b; char c; }; void __cdecl Test2(char a, unsigned long long b, char c) { TestStruct locals; locals.a = 'b'; locals.b = 4; locals.c = 'r'; printf("%d %d - %d - %d %d Total: %d\n", (long)&locals.b - (long)&locals.a, (long)&locals.c - (long)&locals.b, (long)&a - (long)&locals.c, (long)&b - (long)&a, (long)&c - (long)&b, (long)&c - (long)&locals.a ); }; int main() { Test1('f', 0, 'o'); Test2('f', 0, 'o'); return 0; } And this spits out the following: 9 19 - 13 - 4 8 Total: 53 8 8 - 24 - 4 8 Total: 52 The function args are well behaved but as the calling convention is specified, I'd expect this. But the local variables are a bit wonky. My question is, why wouldn't these be the same? The second call seems to produce a more compact and better aligned stack. Looking at the ASM is unenlightening (at least to me), as the variable addresses are still aliased there. So I guess this is really a question about the assembler itself allocates the stack to local variables. I realise that any specific answer is likely to be platform specific. I'm more interested in a general explanation unless this quirk really is platform specific. For the record though, I'm compiling with VS2010 on a 64bit Intel machine.

    Read the article

  • Html how to make a part on iframe, unvisible and unclickable externally? (my idea)

    - by ozan
    I have a page (A) including a BUTTON with a function close_window() , however when I embed A to my main page (B) using iframe, the close_window() can't work as expected since there is no more window anymore, and I am not able to remove the button from the iframe since A is on another domain (Security issues prevents). What I want to do is make this button label invisible. And the only way I think is to put a white image just to the place where that button exists on my iframe, externally. is Smthing like that possible? I want the image to be on the top of iframe? Or do you have any other idea ? Thanks for helps.

    Read the article

  • how to build custom menu using asp.net

    - by Turi
    hi all, i have this situation: i have to build a menu with datasource from the db, because i have to filter them among the user that is loged in. i have tried building a menu using repeater, and all this works fine till i realized that i wanted the menu with more than two levels. i have also tried with treeview, but i really don't want this solution (problem with the style and the treeview doesn't have a pretty view). Could anyone give me any ideas ? thnx in advance.

    Read the article

  • What is the difference between Row Level Security and RPD security?

    - by Jeffrey McDaniel
    Row level security (RLS) is a feature of Oracle Enterprise Edition database. RLS enforces security policies on the database level. This means any query executed against the database will respect the specific security applied through these policies. For P6 Reporting Database, these policies are applied during the ETL process. This gives database users the ability to access data with security enforcement even outside of the Oracle Business Intelligence application. RLS is a new feature of P6 Reporting Database starting in version 3.0. This allows for maximum security enforcement outside of the ETL and inside of Oracle Business Intelligence (Analysis and Dashboards). Policies are defined against the STAR tables based on Primavera Project and Resource security. RLS is the security method of Oracle Enterprise Edition customers. See previous blogs and P6 Reporting Database Installation and Configuration guide for more on security specifics. To allow the use of Oracle Standard Edition database for those with a small database (as defined in the P6 Reporting Database Sizing and Planning guide) an RPD with non-RLS is also available. RPD security is enforced by adding specific criteria to the physical and business layers of the RPD for those tables that contain projects and resources, and those fields that are cost fields vs. non cost fields. With the RPD security method Oracle Business Intelligence enforces security. RLS security is the default security method. Additional steps are required at installation and ETL run time for those Oracle Standard Edition customers who use RPD security. The RPD method of security enforcement existed from P6 Reporting Database 2.0/P6 Analytics 1.0 up until RLS became available in P6 Reporting Database 3.0\P6 Analytics 2.0.

    Read the article

  • What would be the level of effort required to implement a screencapture command on a PS3 game?

    - by Sean Scott
    Looking to see what the level of effort is for implementing a screen capture command into PS3 game by a mid-level PS3 game developer. Bonus for a description of what is involved in the process... EDIT Not sure how to get back my question since it was the first but let me clarify some things. @Nate Bross, nope I am not the actor although i've fielded calls for him on occasion @coderanger my intent was to try and speak to other PS3 developers, however coming from a web development no one in my social circle close or extended develops on the PS3. Additionally i'm interested in hearing the effort required in terms of hours so that this information can be passed on to a client. A client who has a game on the PS3 using the unreal engine. Convo with devs sometimes go something like "can you implement feature a" which gets a response "this will take us 8 weeks and an army". Trying to be educated before the ask. I hope that helps If anyone here is a PS3 game dev and would like to respond off site so as not to break NDA that would be awesome. @Roger it would be from within the game, something that users can use. Something akin to the iphone screencap utility. No need to get fancier than that.

    Read the article

  • Demantra 7.3.1.3 Controlling MDP_MATRIX Combinations Assigned to Forecasting Tasks Using TargetTaskSize

    - by user702295
    New 7.3.1.3 parameter: TargetTaskSize Old parameter: BranchID  Multiple, deprecated  7.3.1.3 onwards Parameter Location: Parameters > System Parameters > Engine > Proport   Default: 0   Engine Mode: Both   Details: Specifies how many MDP_MATRIX combinations the analytical engine attempts to assign to each forecasting task.  Allocation will be affected by forecsat tree branch size.  TaskTargetSize is automcatically calculated.  It holds the perferred branch size, in number of combinations in the lowest level. This parameter is adjusted to a lower value for smaller schemas, depending on the number of available engines.   - As the forecast is generated the engine goes up the tree using max_fore_level and not top_level -1.  Max_fore_level has     to be less than or equal to top_level -1.  Due to this requirement, combinations falling under the same top level -1     member must be in the same task.  A member of the top level -1 of the forecast tree is known as a branch.  An engine     task is therefore comprised of one or more branches.     - Reveal current task size       go to Engine Administrator --> View --> Branch Information and run the application on your Demantra schema.  This will be deprecated in 7.3.1.3 since there is no longer a means of adjusting the brach size directly.  The focus is now on proper hierarchy / forecast design.     - Control of tasks       The number of tasks created is the lowest of number of branches, as defined by top level -1 members in forecast       tree, and engine sessions and the value of TargetTaskSize.  You are used to using the branch multiplier in this       calculation.  As of 7.3.1.3, the branch ID multiple is deprecated.     - Discovery of current branch size       To resolve this you must review the 2nd highest level in the forecast tree (below highest/highest) as this is the       level which determines the size of the branches.  If a few resulting tasks are too large it is recommended that       the forecast tree level driving branches be revised or at times completely removed from the forecast tree.     - Control of foreacast tree branch size         - Run the following sql to determine how even the branches are being split by the engine:             select count(*),branch_id from mdp_matrix where prediction_status = 1 and do_fore = 1 group by branch_id;             This will give you an understanding if some of the individual branches have an unusually large number of           rows and thus might indicate that the engine is not efficiently dividing up the parallel tasks.         - Based on the results of this sql, we may want to adjust the branch id multiplier and/or the number of engines           (both of these settings are found in the Engine Administrator)           select count(*), level_id from mdp_matrix where prediction_status = 1 and do_fore = 1 group by level_id;           This will give us an understanding at which level of the Forecast tree where the forecast is being generated.            Having a majority of combinations higher on the forecast tree might indicate either a poorly designed forecast           tree and/or engine parameters that are too strict           Based on the results of this we would adjust the Forecast Tree to see if choosing a different hierarchy might           produce a forecast, with more combinations, at a lower level.           For example:             - Review the 2nd highest level in the forecast tree, below highest/highest, as this is the level which               determines the size of the branches.             - If a few resulting tasks are too large it is recommended that the forecast tree level driving branches               be revised or at times completely removed from the forecast tree.               - For example, if the highest level of the forecast tree is set to Brand/All Locations.             - You have 10 brands but 2 of the brands account for 67% and 29% of all combinations.             - There is a distinct possibility that the tasks resulting from these 2 branches will be too large for               a single engine to process.  Some possible solutions could be to remove the Brand level and instead               use a different product grouping which has a more even distribution, possibly Product Group.               - It is also possible to add a location dimension to this forecast tree level, for example Customer.                This will also reduce forecast tree branch size and will deliver a balanced task allocation.             - A correctly configured Forecast Tree is something that is done by the Implementation team and is               not the responsibility of Oracle Support.  Allocation will be affected by forecast tree branch size.  When TargetTaskSize is set to 0, the default value, the system automatically calculates a value for 'TargetTaskSize' depending on the number of engines.   - QUESTION:  Does this mean that if TargetTaskSize is 1, we use tree branch size to allocate branches to tasks instead                of automatically calculating the size?     ANSWER: DEV Strongly recommends that the setting of TargetTaskSize remain at the DEFAULT of ZERO (0).   - How to control the number of engines?     Determine how many CPUs are on the machine(s) that is (are) running the engine.  As mentioned earlier, the general     rule is that you should designate 2 engines per each CPU that is available.  So for example, if you are running the     engine on a machine that has 4 CPU then you can have up to 8 engines designated in the Engine Administrator.  In this     type of architecture then instead of having one 'localhost' in your Engine Settings Screen, you would have 'localhost'     repeated eight times in this field.     Where do I set the number of engines?                 To add multiples computers where engine will run, please do a back-up of Settings.xml file under         Analytical Engines\bin\ folder, then edit it and add there the selected machines.                 Example, this will allow 3 engines to start:         - <Entry>           <Key argument="ComputerNames" />           <Value type="string" argument="localhost,localhost,localhost" />           </Entry Otherwise, if there are no additional engines defined, the calculated value of 'TargetTaskSize' is used. (Oracle does not recommend changing the default value.) The TargetTaskSize holds the engines prefered branch size, in number of level 1 combinations.   - Level 1 combinations, known as group size The engine manager will use this parameter to attempt creating branches with similar size.   * The engine manager will not create engines that do not have a branch. The engine divider algorithm uses the value of 'TargetTaskSize' as a system-preferred branch size to create branches that are more equal in size which improves engine performance.  The engine divider will try to add as many tasks as possible to an existing branch, up to the limit of 'TargetTaskSize' level 1 combinations, before adding new branches. Coming up next: - The engine divider - Group size - Level 1 combinations - MAX_FORE_LEVEL - Engine Parameters  

    Read the article

< Previous Page | 34 35 36 37 38 39 40 41 42 43 44 45  | Next Page >